Home

data†aker®

image

Contents

1. a System Display and Keypad Models on DT600 and DT605 only Type LCD 2 lines by 16 characters back light Display functions channels data alarms battery status data capacity Key pad 5 keys for scrolling function execution Beeper for alarms etc Indicator LED s 3 programmable Real Time Clock For time stamping of data scheduling and timers Normal resolution 1 second Accuracy 2 seconds per day 25 C Power Supply Voltage range 11 to 24Vdc or 9 to 18Vac Power Consumption In normal mode 1W 2W with battery charging Sleeping 2mW 3504A from battery Typical low power operation 20mW Internal Main Battery Chemistry lead acid gel cell Digital Channels Number of channels Bi directional channels 4 Dedicated counter channels 3 Digital Input Number 4 shared with output channels Input Type logic level protected and 5k pull up to 5V Counter Channels Number 4 low speed 10Hz shared with input channels 3 high speed 1kHz sleep mode with switchable internal clocking options 16 bit 65 535 counts Digital Output Analog Channels Channel Number Number of input channels depends on sensor wiring configuration Sensor configurations may be mixed Two wire 10 Two wire with one shared terminal 30 Three wire 10 Four wire 10 Expansion by Channel Expansion Modules CEM Size Fundamental Input Ranges Full Scale Resolution
2. E G J K N R S T Reference junction compensation accuracy Case temperature 20 to 60 C Accuracy Ore H SRC RTDs Types Pt Ni Cu Resistance range 10Q to 2kQ Measurement accuracy 4 wire 0 15 of resistance value 3 wire 0 25 of resistance value Monolithic Temperature Sensors Types supported LM34 LM35 AD590 Thermistors Types YSI 400xx Series Resistance range lt kQ lt 20kQ with parallel resistor Bridge Sensors Configurations 4 wire and 6 wire Bridge completion external or internal half bridge C 4 20mA Current Loops Shunt value 100 to a shared common Accuracy 0 25 at 25 C Sensors Comments A wide range of sensor scaling and linearising facilities is provided including polynomials expressions and functions Serial Interface RS232 The DT500 range are programmed and data extracted via the RS232 serial interface Speed 300 to 9600 baud 9600 default Handshake XON and XOFF Wake from sleep yes Isolation 500V Compatibility computers modems satellite modems radio modems and printers Network Interface Multiple dataTaker only Standard RS485 Protocol proprietary with error correction Speed 1200 Baud Distance 1000 meter maximum datalaker Certified to 1S09002 TOTAL QUALITY COMMITMENT dataTaker DeLogger are either registered trademarks or trademarks IT and Instrumentation for industry Amplicon Sales 4
3. 4 0 1273 570 220 Website www amplicon com Email sales amplicon com
4. Datasheet Bo datalaker Data Acquisition and Data Logging Systems dataTaker DT500 amp DT600 series 3 Range e General Purpose Low Power Data Logger e 10 30 Sensor Channels 7 Digital Channels e Unique Universal Channels e Up to 1 390 000 Data Points e PC Card for Data Storage Easily Configurable Windows Based Software e Stand Alone and Real Time Data Acquisition e Remote Monitoring and Control e Removable Screw Terminals e Expandable Datataker s Extensive Range Datataker s extensive range of data acquisition and data logging systems are real time and stand alone able to acquire process and log data without direct computer control The powertul yet easy to use hardware and software enables you to log a wide range of measurements and events datalakers are in use in over 50 countries datalakers are used in many applications including science aerospace mining manufacturing meteorology agriforestry hydrography petrochemical public utilities and transportation The datalaker DT500 amp DT600 Range The datalaker DT500 range of general purpose battery powered data acquisition and data logging systems measure inputs from most sensor types Data can be conveniently and securely stored in battery backed RAM and removable memory cards The datalaker DT500 range consists of four models e DT500 Basic Unit with Solid State Channel Selector e DT600 Solid State Channel Selector amp LCD Display and Keypad
5. Full Scale Number 4 shared with input channels poles capacity 6V 1 a n ae Output type open collector npn transistor emperature compensation 10 C to 70 ieee bo a nN a 5 Rating 30V 100mA Operating time Normal a Ae en z Low power approximately 3 months ee Ve ee ars Calculation Channels Internal Backup Battery f fee Vde 500 uV 100 Hz Any expression involving variables and functions including 0 25 mA 0 2 uA 10 kHz For real time clock and internal data storage backup oie TA T sin cos tan asin acos atan abs sqrt Tyne 3V WAA Lithium 95 a rae average maximum minimum time of max time of ype 5 Seu M min variance integral histogram Physical and Envi ronment 100 Vdc range of DT505 and DT605 only Scheduling of Data Acquisition Construction Powder coated fabricated steel Accuracy Number of schedules 4 acquisition schedules Physical dimensions 260 x 110 x 85mm _ diaieschedule height 104mm with PC Card Measurement at 45 C to 60 C 1 imme ee a 7 AL a E 1 alarm schedule Weight 2 2kg 4kg shipping ae iS tage ABE RAEN Scan triggers time base or digital event Environment temperature range 45 C to 70 C DC Saree 0 20 030 Conditional scanning while digital input high Humidity 85 RH non condensing ee aba SA Time based scheduling from seconds to months in Accessories Included Line adaptor 110 240Vac 500mA Comms cable for PC with 9 to 25 pin adaptor Soft
6. e DT505 Basic Unit with Relay Channel Selector Hae i 3 e DT605 Relay Channel Selector amp LCD Display and Keypad Te n The DT600 and DT605 both have an integral display and keypad that allows users to view channel pis Ee data alarm status and system information including time battery status and amount of data stored 3 Programmable function keys allow keypad control over the unit s operation The datalaker Windows Based Software Datataker produces a number of software packages for interfacing with the datalaker data logger range DeTransfer provides a text based interface for programming and management with simple plotting provided by the DePlot utility DeLogger4 is our standard GUI Graphical User Interface for drag and drop programming spreadsheet presentation of data plotting of charts and simple mimics DeLogger4 Pro is the enhanced graphical package including additional automation reporting database and remote datalaker management features Applications Applications for the datalaker DT500 range include e Fault Finding e Monitoring Climatic Conditions e Monitoring Water Levels and Flood Warnings e Process Monitoring Product Testing e Building Monitoring e Research amp Development e Automotive Testing For your unique application contact your local datataker dealer IT and Instrumentation for industry Amplicon Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com Datasheet
7. e channels 1 Internal battery voltage 1 Sensor Support Type battery backed SRAM Capacity 166 530 data points PC Card Types SRAM up to 4MByte Type 1 Card voltage 5V types Capacity up to 1 390 000 data points Data format proprietary Download Data Format Format ASCII floating point fixed point or exponential formats Compatibility spreadsheets word processors graphing packages statistical programs and SCADA software 30 two wire shared terminals 20 digital inputs 10 digital outputs 5 with relay contacts Portable Carrying Case PE500 Capacity 1 DT500 range unit 1 x CEMS3 Requires AS1072 Environmental protection IP66 SRAM PC Card MC1024P MC4096P Capacity 1MByte approximately 340 000 data points AMByte approximately 1 390 000 data points DeLogger 4 Pro Graphical programming and supervision software Supports a large network of DT500 range units connected via modem Features include comprehensive plotting reporting mimics database web publishing and other powerful capabilities Warrant The datalaker DT500 and DT600 range is covered by a 3 year warranty on workmanship and parts For further information on the dataTaker range or for useful downloads visit the dataTaker web site at www datataker com or contact your nearest Datataker office or dealer datalaker Supports a wide range of sensors types including but not limited to the following Thermocouples Types B C D
8. ware Software Suite CD which includes DeLogger4 110 DeTransfer DePlot applications Manuals Getting Started with datalaker increments of 1 second 1 minute 1 hour and 1 day Maximum scheduled rate 1 second or as fast as possible typically 25 samples per second Dynamic scan time base change yes Maximum number of channel entries Multiplexer Channel Selector DT500 and DT600 solid state 5V input range DT505 and DT605 relay 100V input Input impedance 1MQ or gt 100MQ programmable Common mode range DT500 and DT600 3 5V Alarms User s Manual DT505 and DT605 100V on 100V range Condition high low within range and outside range Options amp Accessories Sampling Delay optional time period for alarm response Channel Expansion Module CEMS3 Multiplexer relay Number 2 per DT500 Series unit Channel number 10 two wire Actions set digital outputs execute any dataTaker commands Alarms can be combined in a logical fashion Data Storage Internal Sampling for accuracy and noise rejection by integrating over 50 60Hz line period Maximum sample speed 25Hz up to 70Hz without noise rejection Effective resolution 15 bits Linearity 0 01 Common mode rejection 25mV range gt 90dB Line 50 60Hz series mode rejection gt 35dB Sensor Excitation Each channel 4 5V 250uA or 2 5mA DC voltage 5V at 100mA max switched Internal Channels Temperature thermocouple reference junction 1 Reference voltag

Download Pdf Manuals

image

Related Search

data databricks database data annotation datacamp datadog datatree datasite login datavant dataiku datasite datalounge data soft logic data center datarails dataverse data entry jobs data science datatree login data management data loader data annotation tech data recovery datagrip data warehouse data mining

Related Contents

Untitled - Smartphone  教 育 用 肺 活 量 セ ン サ PS-2152  Shark 200 Meter Manual - Spanish V.1.10  AXIS F41 Main Unit - User Manual - IT-Wave    Allegato - Comune di Palermo  Enfermedad osteoarticular y del tejido conectivo  42WL66A User Manual  configurazione delle funzioni  高解像度DAY&NIGHT IRカメラ SCO  

Copyright © All rights reserved.
Failed to retrieve file