Home

Maximiser Progressive User Manual

image

Contents

1. Time Off Menu 2 Reset Power Time Menu Reset to Start 00 Reset time Off Menu 3 Calibrations Frequency 20 Hz Nitrous Delay 0 10 Secs Retard output on 30 Max Flow 100 Menu 4 Saved Settings Load Save Overview 1 Initial screen if wired properly and power switch activated 2 Comes on after screen 1 in sequence Push up arrow on front panel for automatic scroll of functions and settings 3 Press up arrow on front panel to go to main menu and make changes to settings 4 Screen that needs to be shown for Maximiser to operate in race mode 5 Main menu to select menu of functions Use arrows on front panel to select MAXIMISER MAXIMISER MAXIMISER pll HECK 5 t Hoh J Digital Progressive Control Digital Progressive Control Back Next Function L OFF Decrease A ON Increase Digital Progressive Control MAXIMISER gt Digital Progressive Control Menu 1 Initial Delay The time the nitrous system can be delayed from activating after the throttle switch is operated can be adjusted between 0 1 and 9 9 seconds Selecting less than 0 1 will turn this feature OFF Example A 1 5 delay will turn the nitrous system on 1 5 seconds into the run after switch activation Function will not affect or Cause gear change delays Build time The time it takes the nitrous power to build up from the start percentage to the final power can be adjusted between 0 1 to 9
2. at a given nitrous power level Range of 70 to 100 The nitrous solenoid will start to flow 100 Hoe PULSE PDE earlier than 100 because of the high pressure situation The fuel E solenoid is still pulsing and delivering fuel accurately to 95 100 because of a lower pressure This can cause a lean out so match WGA the percentage for when the nitrous side starts to flow wide open and the fuel side will stop pulsing and go wide open also U S solenoids can be as low as 60 Highpower solenoids are about 85 95 MAXIMISER Max Pulse Width Set Up a Turn the bottle off and have no nitrous pressurising the system b Activate the system while listening to the nitrous solenoid pulsing and watching the nitrous bar percentage on the Maximiser screen this may require 2 people c Set this feature up to the percentage where the nitrous pulsoid stopped pulsing compared to the nitrous bar percentage 90 when the nitrous solenoid stopped pulsing would indicate a 90 setting MAXIMISER N20 Timer Set Bottle Contents Indicator These settings allow the usage of nitrous oxide to be measured ets MEM E by the Maximiser POWER 25BHFt A Power Using the arrow keys select the power level your ESR R EES AOUN System is currently using E G if you re using 25 BHP jets select 25 BHP B Weight Using the up and down keys select the total bottle capacity in nitrous pounds If the bottle isn t full select the weight of the nitrous remainin
3. back off the throttle the restart power level will be 30 reset again and it restarts at 40 this will continue up to 80 The opposite would occur if you selected 10 MAXIMISER a la Time after each gear change until reset activates Ranges from 3 to 3 seconds N20 Pressure Offset This option allows the user to slowly reduce the fueling of the system to compensate for nitrous bottle pressure loss range of 0 15 AFA TESSO Using the up and down keys cycles the option between OFF and a value between MIN 3 0 S and MAX 19 9 S This is the delay time before the fuel will start to be reduced Example A fuel reduction of 10 and set at 4 5 seconds will cause the fuel pulsoid to flow 10 less fuel 4 5 seconds into the run and stay this way for the remainder of the run until the nitrous system is de activated MAXIMISER Digital Progressive Control MAXIMISER H20 DELAY Gifs t Digital Progressive Control MAXIMISER Digital Progressive Control MAXIMISER 20 FUEL RATIO 3 Digital Progressive Control MAXIMISER Digital Progressive Control Menu 3 Frequency Adjustment Different solenoids pulse best at different frequencies To allow the Maximiser to be used with all types of solenoids the frequency can be adjusted to achieve optimal results The range of adjustment for this feature is 8 to 50hz Competitors solenoids work best at 11 16hz Highpower solenoids work at 20 hz for a smoother del
4. 9 seconds Example A 2 5 build time will result in taking 2 5 seconds from start power to end power If reset menu 2 function is turned on build time will be taken into account each gear change Refer to Menu 2 for more options Start Power The percentage of full power that is delivered when the system is first activated is adjustable from 15 to 100 Can be set lower or higher than end power Example A Set lower than end power for optimal traction and smaller initial power delivery B Set higher than end power to spool turbo or make earlier power until boost peaks on a s c Final Power The percentage of full power that is delivered at the end of the build time is adjustable from 15 to 100 Can be set lower or higher than start power Example A Set higher then start power for standard full power later in the rom range where a motor can handle more nitrous safely B Set lower than start power once turbo or s c is making peak boost and providing the power needed Run Timer The run time that the nitrous system is activated for can be adjusted to restrict the system operation to a desired length of time after the initial activation The range of adjustment for this feature is OFF 4 1 to 20 seconds Example Nitrous is used to spool turbo and once peak boost is reached nitrous can be turned off completely Same applies once a s c reaches peak boost levels Menu 2 Please note that in Street mode this feature can
5. Wizards PeEO C Maximiser Progressive Controller Street amp Race Model Owner s Manual Digital Pro 44 0 01302 834343 www noswizard com Introduction Congratulations on purchasing the Maximiser for the ultimate in progressive nitrous control By following the proceeding instructions you will ensure safe and reliable nitrous performance If for any reason you have questions please use our message board contact your nearest dealer or contact us direct for assistance Your Maximiser is covered by a lifetime warranty should you have any problems with the equipment please let us now immediately and we ll either repair it or replace it free of charge The following pages will give you a thorough explanation of the features on your STREET and RACE unit The features in red represent optional RACE mode programs Either the STREET or RACE UNIT can be upgraded to have the Bottle Contents Indicator feature activated A WARNING Wire the Maximiser as shown in the following wiring diagrams The shorter you keep the red blue and black wires the more efficiently the unit will work Not following the advice below may result in system damage or at worst serious engine damage 1 Do not activate the unit without the black wire connected to ground 2 Do not connect any of the wires to 12V except the orange 3 Do not connect any solenoids to the Maximiser which have not had the coil resistance checked and tested against the manu
6. any adjustments that you may of selected in menu 2 If WOT is not re activated within 5 seconds the unit re sets to the Ready to Race screen to begin the original sequence of settings Test Mode The unit has a Test mode so inputs outputs and system functionality can be fully tested a Have the unit powered down b Hold the left and right arrows while powering up the unit c When the first screen is displayed release the keys and the Test Mode Yes No screen should appear Press the up arrow to enter d The screen will then show each keypad arrow individually You press each keypad arrow on the physical unit that corresponds with the screen arrow to make sure the keypad is working correctly e The unit will now show the following screen to test that the pulsoids work properly Pressing MAXIMISER the following keys will activate the corresponding outputs This allows you to test each output and it s wiring separately Pressing 1 M v 18 the up arrow labeled N2O will fire the nitrous solenoid Pressing the down arrow labeled FUEL will fire the fuel solenoid Pressing DY Aenean the left back arrow labeled N amp F will fire both the nitrous and fuel solenoids Pressing the forward right arrow labeled RETARD will trigger an external retard box Important Avoid injecting nitrous only into the engine running or not A Static Test can also be performed using this function Consult your nitrous system installation manual or r
7. etailer for more information about the Static Test Reset Unit to Factory Defaults If you wish to clear all the memory in the unit and return to factory defaults for whatever reasons then follow these sequence of events a Have the unit powered down b Hold the up and down arrows while powering up the unit c After main initial screen appears release buttons and unit will show another screen with the reset option d Select reset Note Re setting to factory defaults will cause all saved files to be lost Upgrade Feature Above the word reset you will also have the option to upgrade Selecting upgrade will take you to the upgrade screen where the unit serial number will be displayed For an upgrade to Race or Bottle Contents Indicator to be possible you must first acquire an unlock code from Highpower Systems or nearest agent retailer The unlock codes are unique to each unit but for us to give you the code you must have the unit serial number to hand Important Do not attempt to enter a code without being sure it s correct Entering an incorrect code 5 times will lock the unit out If this occurs the unit will have to be returned and have anew chip installed Example code is 234 165 32 You can enter the upgrade code by using the up and down keys until the correct 2 or 3 digit number value is reached then using the right arrow to move to the next number Note There are 3 spaces to enter numbers Keep hold in
8. facturers specification Replace coils that are not to specification as faulty coils can burn out the Maximiser power Mosfets 4 Do not connect the purple wire to any load greater than 10 amps without the use of a relay Do not connect directly to an aftermarket ignition system as this may cause interference 5 Do not mount the unit close to a high performance ignition system or HT leads Note Mount the Maximiser as close as possible to the solenoids If you need to extend the wiring harness for any reason take care to use the same grade of wire as used on the Maximiser Using a smaller grade may cause electrical problems Dimensions 7 L x 2 75 H x 1 25 D OPTIONAL TPS Switch Installation 1 Using a digital volt meter and with the ignition switched on determine which wire on the throttle position sensor gives either a O to 5 volt reading or the reverse on some applications as the throttle is activated When you have determined the right wire on your TPS sensor connect the white wire from the TP1 unit to it 2 For direct feed from battery Wire the remaining wires as shown following page but leave the pink pink wire will activate the solenoids and red wires disconnected a Turn the ignition on b Press and hold the TPS set button an connect the red TPS wire to power 12 V Release the set button and the led should illuminate for 2 seconds c Open the throttle using the pedal to the position that you want the Nitrous Sy
9. g C To Reset Once you ve adjusted the Contents Indicator settings then you must reset the counter for it to work Once you do this a figure in the top right of the RACE READY screen will show This indicates the approximate nitrous remaining time you have in seconds You should also use the reset feature whenever you get your bottle s re filled Debounce Delay Allows the user to reduce any possible keypad interference from powerful ignition systems If you use a powerful ignition system try adjusting the setting to around 0 10 s If you still think interference is a problem then please contact us for further help MAXIMISER Digital Progressive Control Menu 4 File Menu This is a 10 store data log in which you can store up to 10 sets of adjustments which you may want to repeat without having to make notes of each individual setting and reload individually when s required With this unique feature you can save ALL the DEF ESSO adjustments made in an individual numbered log for reloading at a later date File Load Select saved file and load settings Activated Screen Bars and Percentages Once the unit has been activated when WOT is reached from the Ready to Race screen it will display 2 bar graphs and 2 x figures which indicate the current power level If the throttle is released for any reason the unit will display THROTTLE OFF This indicates the unit is waiting to see a WOT signal and has made
10. g up arrow to reach 234 to fill soace one etc Once all numbers are correct press right again to enter the code Providing the code is correct the screen should display Upgrade Ok Troubleshooting Problem Screen flashes back and forth from Throttle OFF to bars percentages Unit does not power up Unit turns off and comes back on intermittently Upgrade code does not work Cause Check that the white wire has a good connection Check power ground connections and fuse Check that the white wire has a good connection If using a micro switch check adjustment If using a TP1 check throttle angle settings Check ground connection Make sure numbers are being added correctly Example 138 does not mean 1 then next number is 3 etc First number must scroll all the way to 138 as one number and then move to the next set NOTES Lifetime Warranty Highpower products are covered by a Lifetime warranty against any defects for the lifetime of the original purchaser This warranty does not cover any damage done by modifying or tampering of the original product outside of a Highpower representative If any part becomes faulty please contact a Highpower office with proof of purchase for an exchange or warranty coverage Importer for and affiliated with Highpower Systems International Ltd Rands Lane Armthorpe Doncaster South Yorkshire England DN3 3ER UK 44 0 01302 834343 www noswizard com
11. ivery Nitrous Delay The activation time of the nitrous can be delayed relative to the fuel activation This feature eliminates initial lean out which all systems with pipe lengths longer than 3 will suffer to some degree Fuel pressure is much lower than nitrous pressure so the nitrous solenoid should be delayed until the fuel catches up Problem becomes worse the higher the power demands Range of OFF 1 second Fuel Delay Adjust up to the desired setting your vehicle requires This setting will delay the opening of the Fuel solenoid output only to match the slower delivery time of the nitrous on some air box or dry systems Common for bike nitrous systems Range of OFF 1 second N20 Fuel Ratio Adjusts the ratio between nitrous and fuel by limiting one pulsoid to a lower overall percentage than the other Nitrous pulsoid is always fixed at 1 and fuel pulsoid ranges from 8 1 2 to either richen or lean out mixture Note Be careful with this setting as it gives you the ability to lean out the system which could if used incorrectly cause damage to your engine Ignition Retard Output This is an adjustable switched output that can be set to activate at any percentage of power and is typically connected to an aftermarket ignition system with a switched retard feature The range of adjustment for this feature is OFF to 100 Example An aftermarket ignition like MSD has a retard feature that can be activated by the Maximiser
12. only be used as a Nitrous Free operation 0 power The Race mode chip is required to unlock the full potential of this feature Range of 20 100 power Digital Progressive Control Using the up and down keys will scroll the options between A On Button Push This allows the user to exit the burn out mode at any time by push ing a key Doing this allows the unit to become Race Ready B On 1 Operation The unit will become Race Ready after one Burn Out operation one throttle operation To exit this straight to Race Ready without using the Burn Out operation press any key C On 2 10 Operations As above but after 2 10 Burn Out operations MAXIMISER Reset Options The reset function is mainly intended for manual transmission applications when you want the Maximiser to reset every gear change A Reset Off Hold The unit will hold at whatever power you release the throttle and continue from that when you press the TE CENAN throttle again B Reset to Start Maximiser will reset to start power after each de activation and activation of throttle gear change Reset Power Level With this option in use every time you cycle the throttle switch on and off the Maximiser will increase the reset start power setting by an amount that is adjustable between 30 and 30 i e if you choose this XX option and set the value to 10 with the Start Power set at 20 the first time you reset as you
13. stem to activate between 80 and 90 of full throttle and then briefly press the set button again The LED should illuminate for 2 seconds again and then switch off which indicates that the unit is ready for use Opening the throttle to WOT should now cause the LED to illuminate d Now wire remaining wires with power switched off 3 For connection to 12V ignition Wire the remaining wires as shown but leave the pink pink wire will activate the solenoids disconnected a Press and hold down the set button with the ignition turned off b Turn on the ignition switch to IGN only not Start and release the set button The LED should illuminate for 2 seconds after you release the set button c Open the throttle using the pedal to the position that you want the Nitrous System to activate between 80 and 90 of full throttle and then briefly press the set button again The LED should illuminate for 2 seconds again and then switch off which indicates that the unit is ready for use Opening the throttle to WOT should now cause the LED to illuminate d Now connect the pink wire as shown after the unit has been set 4 Operating the pedal throttle past the set position should activate the Pulsoids at this time the LED should light up Mounting Instructions The Maximiser unit has a slot on the back of the case which can be used in conjunction with the hardware provided to mount the Maximiser however you feel appropriate The mounting bracke
14. t can also be bent to provide additional 8 B com mounting options Slide the flat head screw shown into the groove on the back of the Maximiser Then screw down the bracket to your chosen surface Micro Switch Diagram Purple GND output to activate a relay 10 amp max load Black Solenoid White Fuel mee Solenoid Battery Ignition Switch 12 volts lr Arming Switch sw3 Throttle Operated Micro Switch e White Ground u Throttle Position Switching Unit TPS Diagram Purple GND output to activate a relay 10 amp max load Black Solenoid Swi 20 AMP FUSE Fuel iii Red Solenoid Battery White Orange Ignition Switch 12 volts J Arming Switch d TP1 Ground White Existing Throttle Position Sensor i Black Throttle Position Switching Unit SET Button Pink Getting Started Once the unit is fully wired properly you are ready to power the Maximiser up and scroll through the screens of features Turn the arming switch to the ON position and you will see the product ID screen MAXIMISER 9000 version no STREET means the STREET preset has been selected 1848 unit serial number Note The Maximiser has been pre programmed from the factory with the following settings Menu 1 Power Time Menu Initial Delay O Secs Build Time 5 Secs Start Power 25 Final Power 100 Run

Download Pdf Manuals

image

Related Search

Related Contents

AC20 31069 Manual - Super Systems Europe  Linee d`indirizzo per la sicurezza macchine preparazione  Samsung Galaxy Tab3 10.1 Wi-Fi Uživatelská přiručka  58-14-8988d2  USER`S MANUAL - Virtual Vision  Le Forum des associations, c`est géant !  AT&T 9320/8220 User's Manual  042701 24in TV User Manual  Fermeture de la BU de Gergovia Mode d`emploi  AUTOPAR® WASH LUMINAIRE  

Copyright © All rights reserved.
Failed to retrieve file