fx3u-4da-adp,user`s manual
Contents
1. Do not connect a high speed I O special adapter on the left side of a communication or analog special adapter 2 2 Connection to the FX3uc Series PLC e Refer to the procedure 2 for configuring a new system e Refer to the procedure 1 for adding product to an existing system Procedure 1 Turn off the power Disconnect all the cables connected to the PLC Dismount the PLC from the DIN rail 2 Install an expansion board to the main unit For installation of expansion board refer to the following manual Refer to the manual of the expansion board to be used Remove the special adapter connector cover on the expansion board Right fig A In case of connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated Slide the special adapter slide lock Right fig B of the main unit In case of connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace B the following procedures similarly Connect the special adapter Right fig C to the main unit as shown on the right Slide back the special adapter slide lock Right fig B of the main unit to fix the special adapter Right fig C 3 4 5 6 3 Wiring WIRING PRECAUTIONS DANGER e Cut off
2. Section 1 2 Using voltage ADA ADP output Terminal 1 Shielded lock OO f 10 lt cho como Using current output poccea m EE r Tot lt cho como He External power supply wiring 24 24V DC T 24 1 Grounding Ground resistance 1002 or less VO O ch O represents the channel number 1_ Use 2 core shielded twisted pair cable for the analog output lines and separate the analog output lines from other power lines or inductive lines 2 24V DC service power supply of the FX3U Series PLC can also be used 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 1002 or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the FX3U Series User s Manual Hardware Edition 4 1 Applicable PLC Model name FX3U Series PLC Applicability Ver 2 00 from the first product and later Ver 1 20 from the product manufactured in May 2004 with SER No 45 and later FX3uUC Series PLC The version number can be checked by monitoring D8001 as the last three digits indicate it 4 2 General Specification For the general specification refer to the manual of the PLC main unit The items other than the following are
3. equivalent to those of the PLC main unit Item Specification Conforming to JEM 1021 Between all terminals and ground terminal of PLC Insulation resistance 5MQ or more by 500V DC megger main unit Dielectric withstand 500V AC for one minute voltage 4 3 Power Supply Specification Item Specification D A conversion 24V DC 20 15 150mA for 24V DC circuit driving power Connect a 24V DC power supply to the terminal block 5V DC 15mA 5V DC power is supplied internally from the main unit Interface driving power 4 4 Performance Specification Description Item Voltage output Current output Analog output Oto 10 V DC 4 to 20mA DC range External load 5kQ to 1MQ External load 500Q or less Digital input 12 bits binary Resolution 2 5mV 10V 4000 4uA 16mA 4000 Another Another PLC lequipment PLC lequipment PLC I I ae Independent grounding Shared grounding Best condition Good condition Another equipment Common grounding Not allowed The grounding wire size should be AWG 22 20 0 3 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specification STARTUP AND MAINTENANCE PRECAUTIONS e Do not disassemble or modify the unit Doing so may cause failure malfunction or fire For repair contact your local Mitsubishi Electric distributor e Do n
4. for configuring a new system e Refer to the procedure 1 for adding product to an existing system Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special adapter Dismount the main unit and special adapter mounted on DIN rail or mounted directly using screws Install an expansion board to the main unit For installation of expansion board refer to the following manual Refer to the FX3u Series User s Manual Hardware Edition Remove the special adapter connector cover on the expansion board Right fig A In case of connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated Slide the special adapter slide lock Right fig B of the main unit In case of connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 2 3 4 5 Connect the special adapter Right fig C to the main unit as shown on the right Slide back the special adapter slide lock Right fig B of the main unit to fix the special adapter Right fig C 6 Connection precautions Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination
5. four analog output points 1 1 Incorporated Items Check if the following product and items are included in the package Manual Product 1 2 External Dimensions Part Names and Terminal Layout 5 10 2 1 90 3 55 98 3 86 106 4 18 7 0 28 74 2 92 Special adapter connector cover is removed Weight Approx 0 1 kg 0 22 Ibs 1 DIN rail mounting groove DIN rail DIN46277 2 Name plate 3 Special adapter slide lock Used to connect special adapter on left side of this special adapter 4 Special adapter connector cover Remove this cover for connecting special adapter on the left side 5 Direct mounting hole 2 holes of 4 5 0 18 mounting screw M4 screw Not used when connecting to FX3UC Series PLC 6 POWER LED green Lit while 24V DC power is supplied properly to terminals 24 and 24 7 Terminal block European type Connect the analog output voltage current signal and 24V DC power supply 8 Special adapter connector Used to connect this special adapter to PLC main unit or special adapter 9 DIN rail mounting hook 10 Special adapter fixing hook 11 Special adapter connector Used to connect communication special adapter or analog special adapter to this adapter on left side 2 Installation The product can be mounted on a DIN rail DIN46227 or mounted directly using screws For installation uninstallation and safety prec
6. hazardous conditions resulting in medium or slight personal injury or physical damage Z CAUTION Depending on circumstances procedures indicated by A CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Associated Manuals Manual name Manual No Description FX3U FX3UC Series JY997D16701 Describes specifications for User s Manual MODEL CODE analog control and Analog Control 09R619 5 programming method for FX3U Edition FX3uc Series PLC Eorna rere JY997D16601 Describes PLC programming lt Basic amp Applied MODEL CODE for basic applied instructions ee ey 09R517 and devices Instruction Edition PeU Seres Ta ERK ee Users Manual MODEILCODE wiring installation and Hardware Edition 09R516 maintenance Note FX3UC Series PLC specification details for I O wiring installation and maintenance can only be found in the Japanese Manual How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Applicable standard FX3U 4DA ADP made in June 2005 or later complies with the EC Directive EMC Directive and UL standards UL cUL Further information can be found in the following manual However FX3UC 32MT LT does not comply with EC Directive EMC Directive UL standards UL cUL Refer to FX3U Series Hardware Manual M
7. 001 as the last three digits indicate it 4 2 General Specification For the general specification refer to the manual of the PLC main unit The items other than the following are equivalent to those of the PLC main unit Item Specification Conforming to JEM 1021 Between all terminals and ground terminal of PLC Insulation resistance 5MQ or more by 500V DC megger main unit Dielectric withstand 500V AC for one minute voltage 4 3 Power Supply Specification Item Specification D A conversion 24V DC 20 15 150mA for 24V DC circuit driving power Connect a 24V DC power supply to the terminal block 5V DC 15mA 5V DC power is supplied internally from the main unit Interface driving power 4 4 Performance Specification Description Item Voltage output Current output Analog output Oto 10 V DC 4 to 20mA DC range External load 5kQ to 1MQ External load 500Q or less Digital input 12 bits binary Resolution 2 5mV 10V 4000 4uA 16mA 4000 Another Another Another PLC lequipment PLC lequipment PLC lequipment 1 1 ie ak TE Independent grounding Shared grounding Common grounding Best condition Good condition Not allowed e The grounding wire size should be AWG 22 20 0 3 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specification STARTUP AND MAI
8. JY997D14001B JAPANESE 7 a MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEGF FX3U 4DA ADP Side ENGLISH Changes for the Better USER S MANUAL JY997D14001 Manual Number Revision B U Date June 2005 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective June 2005 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories DANGER and A CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury DANGER Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage Z CAUTION Depending on circumstances procedures indicated by A CA
9. NTENANCE PRECAUTIONS Z CAUTION e Do not disassemble or modify the unit Doing so may cause failure malfunction or fire For repair contact your local Mitsubishi Electric distributor e Do not drop the product or do not exert strong impact doing so may cause damage DISPOSAL PRECAUTIONS DANGER e Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS Z CAUTION e During transportation avoid any impact as the product is a precision instrument Check the operation of the product after transportation e 0 5 50mV for full scale of 10 V when ambient temperature is 25 C 5 C e 1 0 100mV for full scale of 10 V when ambient temperature is 0 C to 55 C e 0 5 80 1A for full scale of 16mA when ambient temperature is 25 C 5 C e 1 0 160uA for full scale of 16mA when ambient temperature is 0 C to 55 C If the external load resistance Rs is less than 5kQ the value calculated from the following formula will be added Addition will be 100mV per 47x100 Rs 47 Total accuracy 0 9 D A conversion 200 us time The data will be updated at every scan time of the PLC 10V 20mMA z gt Output z t4 characteristics 9 z 2 i SAMA 1 i S E g o gt 40004080 S 0 gt 4000 4080 Digital input Dig
10. Supply Wiring For the power supply wiring refer to the FX3U FX3UC Series User s Manual Analog Control Edition 3 3 Wiring of Analog Output For the terminal configuration refer to Section 1 2 Using voltage output Terminal 1 Shielded lock q Vo lt On fie Be como Using current output oo E e as 10 lt cho como External power supply wiring 1 24V DC T 2 4DA ADP Grounding Ground resistance 100Q or less VO I chO O represents the channel number 1 Use 2 core shielded twisted pair cable for the analog output lines and separate the analog output lines from other power lines or inductive lines 2 24V DC service power supply of the FX3u Series PLC can also be used 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 1002 or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the FX3U Series User s Manual Hardware Edition 4 1 Applicable PLC Model name FX3u Series PLC Applicability Ver 2 00 from the first product and later Ver 1 20 from the product manufactured in May 2004 with SER No 45 and later FX3uc Series PLC The version number can be checked by monitoring D8
11. UTION may also be linked to serious results In any case it is important to follow the directions for usage Associated Manuals Manual name Manual No Description FX3U FX3UC Series JY997D16701 Describes specifications for User s Manual MODEL CODE analog control and Analog Control 09R619 5 programming method for FX3U Edition FX3uc Series PLC Eorna rere JY997D16601 Describes PLC programming lt Basic amp Applied MODEL CODE for basic applied instructions eee 09R517 and devices Instruction Edition PeU Seres Ta ERK ee Users Manual MODEILCODE wiring installation and Hardware Edition 09R516 maintenance Note FX3UC Series PLC specification details for I O wiring installation and maintenance can only be found in the Japanese Manual How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Applicable standard FX3U 4DA ADP made in June 2005 or later complies with the EC Directive EMC Directive and UL standards UL cUL Further information can be found in the following manual However FX3UC 32MT LT does not comply with EC Directive EMC Directive UL standards UL cUL Refer to FX3U Series Hardware Manual Manual No JY997D18801 Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for t
12. all phases of power source externally before installation or wiring work in order to avoid electric shock or damage of product WIRING PRECAUTIONS Z CAUTION e Never let cutting chips and wire chips enter the ventilation slits of this product or PLC when performing wiring Otherwise fire failure or malfunction may occur Make sure to observe the precautions below in order to prevent any damage to a machine or any accident which might be caused by abnormal data written in the PLC due to the influence of noise 1 Do not lay close or bundle with the main circuit high voltage power line or load line Otherwise effects of noise or surge induction are likely to take place Keep a safe distance of more than 100 mm 3 94 from the above when wiring 2 Ground the shield wire or shield of a shielded cable at one point on the PLC However do not ground at the same point as high voltage lines Observe the following items to wire the lines to the European terminal board Ignorance of the following items may cause electric shock short circuit disconnection or damage of the product The disposal size of the cable end should follow the dimensions described in this manual Tighten to a torque should follow the torque described in this manual Twist the end of strands and make sure there is no loose wires Do not solder plate the electric wire ends Connect only the electric wires of regulation size Fix the electric wires so that the terminal bl
13. anual No JY997D18801 Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary induced errors not exceeding 10 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed with general good EMC practice for the users complete control system users should expect normal errors as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created e When reading analog values EMC induced errors can be smoothed out by averaging the readings This can be achieved either through functions on the analog s
14. autions refer to the following manuals Refer to the FX3u Series User s Manual Hardware Edition INSTALLATION PRECAUTIONS DANGER e Cut off all phases of the power source externally before starting the installation or wiring work thus avoiding electric shock or damages to the product INSTALLATION PRECAUTIONS Z CAUTION e Use the product in the environment within the general specifications described in PLC main unit manual Hardware Edition Never use the product in areas with dust oily smoke conductive dusts corrosive gas salt air Cle H2S NH3 SO2 or NO2 flammable gas vibrations or impacts or expose it to high temperature condensation or wind and rain If the product is used in such a place described above electrical shock fire malfunction damage or deterioration may be caused When drilling screw holes or wiring cutting chips or wire chips should not enter ventilation slits Such an accident may cause fire failure or malfunction Do not touch the conductive parts of the product directly thus avoiding failure or malfunction Fix the special adapter securely to the specified connector Incorrect connection may cause malfunction 2 1 Connection to the FX3u Series PLC e Refer to the procedure 2 for configuring a new system e Refer to the procedure 1 for adding product to an existing system Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special ada
15. enter the ventilation slits of this product or PLC when performing wiring Otherwise fire failure or malfunction may occur Make sure to observe the precautions below in order to prevent any damage to a machine or any accident which might be caused by abnormal data written in the PLC due to the influence of noise 1 Do not lay close or bundle with the main circuit high voltage power line or load line Otherwise effects of noise or surge induction are likely to take place Keep a safe distance of more than 100 mm 3 94 from the above when wiring 2 Ground the shield wire or shield of a shielded cable at one point on the PLC However do not ground at the same point as high voltage lines Observe the following items to wire the lines to the European terminal board Ignorance of the following items may cause electric shock short circuit disconnection or damage of the product The disposal size of the cable end should follow the dimensions described in this manual Tighten to a torque should follow the torque described in this manual Twist the end of strands and make sure there is no loose wires Do not solder plate the electric wire ends Connect only the electric wires of regulation size Fix the electric wires so that the terminal block and connected parts of electric wires are not directly stressed Properly perform wiring to the terminal block of the FX3U Series PLC following the precautions below in order to prevent electrical shock sho
16. er or analog special adapter to this adapter on left side 2 Installation The product can be mounted on a DIN rail DIN46227 or mounted directly using screws For installation uninstallation and safety precautions refer to the following manuals Refer to the FX3u Series User s Manual Hardware Edition INSTALLATION PRECAUTIONS DANGER e Cut off all phases of the power source externally before starting the installation or wiring work thus avoiding electric shock or damages to the product INSTALLATION PRECAUTIONS Z CAUTION e Use the product in the environment within the general specifications described in PLC main unit manual Hardware Edition Never use the product in areas with dust oily smoke conductive dusts corrosive gas salt air Cle H2S NH3 SO2 or NO2 flammable gas vibrations or impacts or expose it to high temperature condensation or wind and rain If the product is used in such a place described above electrical shock fire malfunction damage or deterioration may be caused When drilling screw holes or wiring cutting chips or wire chips should not enter ventilation slits Such an accident may cause fire failure or malfunction Do not touch the conductive parts of the product directly thus avoiding failure or malfunction Fix the special adapter securely to the specified connector Incorrect connection may cause malfunction 2 1 Connection to the FX3u Series PLC e Refer to the procedure 2
17. he very best per formance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary induced errors not exceeding 10 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed with general good EMC practice for the users complete control system users should expect normal errors as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created e When reading analog values EMC induced errors can be smoothed out by averaging the readings This can be achieved either through functions on the analog special adapters or through a users program in the FX3U Series PLC main unit 1 Outline The FX3U 4DA ADP adapter for analog output hereinafter called 4DA ADP is a special adapter to add
18. ital input e The photo coupler is adopted to insulate the analog output area insulati from the PLC nsuaron e The DC DC converter is adopted to insulate the driving power method A supply line from the analog output area e Channels are not insulated from each other Occupied 0 point This number is not related to the maximum number of points input output points of the PLC This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi E
19. lectric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system sa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100 8310 HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN
20. ock and connected parts of electric wires are not directly stressed Properly perform wiring to the terminal block of the FX3U Series PLC following the precautions below in order to prevent electrical shock short circuit breakage of wire or damage to the product The disposal size of the cable end should follow the dimensions described in this manual Tighten to a torque should follow the torque described in this manual 3 1 Applicable cable and terminal tightening torque 3 1 1 Terminal block European type 1 Wire size Wiring to analog device should use 20 22 AWG wire 2 Applicable cable Type Wire size Single wire 0 3mm to 0 5mm AWG22 to 20 2 wire 2 pieces of 0 3mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve Manufacturer Model Caulking tool Phoenix Contact Co Ltd Al 0 5 8WH CRIMPFOX UD6 Strand wire single wire ec zz 9mm 0 35 14mm 0 55 When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25N m Stick terminal with insulating sleeve Insulation sleeve Contact area 8mm 0 31 2 6mm 0 1 3 2 Power
21. or failsafe functions in the system aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100 8310 HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN JY997D14001B JAPANESE 7 a MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEGF FX3U 4DA ADP Side ENGLISH Changes for the Better USER S MANUAL Manual Number JY997D14001 Revision B U Date June 2005 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective June 2005 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories DANGER and A CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury DANGER Indicates that incorrect handling may cause
22. ot drop the product or do not exert strong impact doing so may cause damage CAUTION DISPOSAL PRECAUTIONS DANGER e Please contact a company certified in the disposal of electronic waste for environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS e During transportation avoid any impact as the product is a precision instrument Check the operation of the product after transportation Z CAUTION e 0 5 50mV for full scale of 10 V when ambient temperature is 25 C 5 C e 1 0 100mV for full scale of 10 V when ambient temperature is 0 C to 55 C e 0 5 80uA for full scale of 16mA when ambient temperature is 25 C 5 C e 1 0 160uA for full scale of 16mA when ambient temperature is 0 C to 55 C If the external load resistance Rs is less than 5kQ the value calculated from the following formula will be added Addition will be 100mV per Total accuracy 47x100 z Rs 47 0 9 D A conversion 200 us time The data will be updated at every scan time of the PLC 10V 20mA z gt Output z t4 characteristics 9 z e 1 4mA I 4 gt g g o gt 40004080 S o gt 14000 4080 Digital input gt Digital input e The photo coupler is adopted to insulate the analog output area Teall from the PLC nsuiaron e The DC DC converter is adopted to insulate the driving power method A s
23. pecial adapters or through a users program in the FX3U Series PLC main unit 1 Outline The FX3U 4DA ADP adapter for analog output hereinafter called 4DA ADP is a special adapter to add four analog output points 1 1 Incorporated Items Check if the following product and items are included in the package Manual Product fa 1 2 External Dimensions Part Names and Terminal Layout 5 10 6 2 y 8 1 90 3 55 98 3 86 106 4 18 7 0 28 74 2 92 Special adapter connector cover is removed Weight Approx 0 1 kg 0 22 Ibs 1 DIN rail mounting groove DIN rail DIN46277 2 Name plate 3 Special adapter slide lock Used to connect special adapter on left side of this special adapter 4 Special adapter connector cover Remove this cover for connecting special adapter on the left side 5 Direct mounting hole 2 holes of 4 5 0 18 mounting screw M4 screw Not used when connecting to FX3UC Series PLC 6 POWER LED green Lit while 24V DC power is supplied properly to terminals 24 and 24 7 Terminal block European type Connect the analog output voltage current signal and 24V DC power supply 8 Special adapter connector Used to connect this special adapter to PLC main unit or special adapter 9 DIN rail mounting hook 10 Special adapter fixing hook 11 Special adapter connector Used to connect communication special adapt
24. pter Dismount the main unit and special adapter mounted on DIN rail or mounted directly using screws 2 Install an expansion board to the main unit For installation of expansion board refer to the following manual Refer to the FX3u Series User s Manual Hardware Edition Remove the special adapter connector cover on the expansion board Right fig A In case of connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated Slide the special adapter slide lock Right fig B of the main unit In case of connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 2 4 5 Connect the special adapter Right fig C to the main unit as shown on the right Slide back the special adapter slide lock Right fig B of the main unit to fix the special adapter Right fig C 2 Connection precautions Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high speed I O special adapter on the left side of a communication or analog special adapter 2 2 Connection to the FX3uc Series PLC e Refer to the procedure 2 for configuring a new
25. rt circuit breakage of wire or damage to the product The disposal size of the cable end should follow the dimensions described in this manual Tighten to a torque should follow the torque described in this manual 3 1 Applicable cable and terminal tightening torque 3 1 1 Terminal block European type 1 Wire size Wiring to analog device should use 20 22 AWG wire 2 Applicable cable Type Wire size Single wire 0 3mm to 0 5mm AWG22 to 20 2 wire 2 pieces of 0 3mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve Manufacturer Model Caulking tool Phoenix Contact Co Ltd Al 0 5 8WH CRIMPFOX UD6 Strand wire single wire c Ke 9mm 0 35 2 6mm 0 1 14mm 0 55 El When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25N m Stick terminal with insulating sleeve Insulation sleeve Contact area 8mm 0 31 3 2 Power Supply Wiring For the power supply wiring refer to the FX3U FX3UC Series User s Manual Analog Control Edition 3 3 Wiring of Analog Output For the terminal configuration refer to
26. system e Refer to the procedure 1 for adding product to an existing system Procedure 1 Turn off the power Disconnect all the cables connected to the PLC Dismount the PLC from the DIN rail 2 Install an expansion board to the main unit For installation of expansion board refer to the following manual Refer to the manual of the expansion board to be used 3 Remove the special adapter connector cover on the expansion board Right fig A In case of connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated Slide the special adapter slide lock Right fig B of the main unit In case of connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace B the following procedures similarly Connect the special adapter Right fig C to the main unit as shown on the right Slide back the special adapter slide lock Right fig B of the main unit to fix the special adapter Right fig C 4 5 6 3 Wiring WIRING PRECAUTIONS DANGER e Cut off all phases of power source externally before installation or wiring work in order to avoid electric shock or damage of product WIRING PRECAUTIONS Z CAUTION e Never let cutting chips and wire chips
27. upply line from the analog output area e Channels are not insulated from each other Occupied 0 point This number is not related to the maximum number of points input output points of the PLC This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup