Home
IncuCount User Manual
Contents
1. REVSCI REVOLUTIONARY SCIENCE The IncuCount Instruction Manual RS IC 150 Revolutionary Science RS IC 150 7 REVOLUTIONARY SCIENCE IncuCount Instruction Manual for the S REVSCI y REVOLUTIONARY SCIENCE Making Science Simple Table of Contents Introduction 2 Parts Checklist Notes Service Record 3 Warranty 4 Safeguards and Cautions Limitations of Use 5 Intended Use 7 Specifications Contact Information 8 Hardware Installation 9 Wi Fi Setup 10 Automatic Updates I Colony Profile Setup I Saving a Colony Profile 12 Calibration Image 12 Setup Lighting Focusing Brightness and Contrast Controls 14 Live Video Feed l6 Capturing Images l6 Colony Counting I7 Count Sensitivity 18 Count Region I8 Colony Size 19 Zoom 20 Adding Removing colonies from count 20 Exclusion Zone 20 Selecting Previous Image 2l Saving Data 21 Export to PDF 2l Antibiotic Reactions Measurement of Inhibition Zones 22 Help 23 Appendix A Camera Settings 23 REVOLUTIONARY SCIENCE 17319 Lake Blvd E mail support revsci com Shafer MN 55074 Website www revsci com Toll Free 800 775 7942 Fax 775 218 7015 IncuCount RS IC 150 R E REV SCI Nw REVOLUTIONARY SCIENCE SCIENCE Introduction Dear Valued Customer Thank you for purchasing the Revolutionary Science RS IC 150 IncuCount We are confident that when used correctly our IncuCount will provide years of reliable service We have made every eff
2. Higher sensitivity is usually needed more with lighter colored colonies and lower sensitivity is usually needed more with darker colored colonies Adjusting the Counting Region To adjust the counting region tap Set Counting Region under the manual tab Then a green circle will appear over petri plate image Touch green circle with one finger and use another finger to adjust the counting region size by sliding it toward or away from first finger To move green circle touch with finger and slide to new location REVOLUTIONARY SCIENCE eR 18 REVOLUTIONARY SCIENCE SCIENCE IncuCount RS IC 150 Q REVSCI E VSCI WW Adjusting Colony Size Parameters Tap on the Manual tab at the top and then on Set Colony Size option You will then see the sliding Max Min scale to the right side of the screen To increase the minimum colony size slide finger up To decrease the minimum colony size slide finger down Min Size Max Size REVOLUTIONARY SCIENCE Ee OO ek a SSEELELEESSSS B 19 REVOLUTIONARY SCIENCE IncuCount RS IC 150 R E VSCI ww Zoom The IncuCount software uses what is typically known as pinch and zoom method To zoom in on a spot simply touch the screen with two fingers together and then slide them apart To zoom out on an area touch the screen with two fingers apart and then slide them together Zoom out Zoom in Manually add colonies Ta
3. APR amp D Inc Limitations of Use Revolutionary Science is not responsible for misuse of the IncuCount 150 ALWAYS pre clean the IncuCount light panel of residue after use with a damp cloth and appropriate mild detergent solution Never clean IncuCount with organic solvents like thinner or benzene It will damage the surfaces CAUTION This is the only recommended method of cleaning 2 Never attempt to dismantle or modify the IncuCount 3 Never operate the IncuCount with a damaged USB cord or after the appliance malfunctions or has been damaged in any manner 4 Accessory attachments not recommended by Revolutionary Science may damage the IncuCount or tablet cpu 5 Never place the IncuCount or any part of the IncuCount in an environment that exceeds 65 degrees Celsius or below 5 degrees Celsius Humidity should be at or below 65 6 Never use IncuCount for any purpose other than the intended use REVOLUTIONARY SCIENCE O 7 39 a SSS FH IncuCount RS IC 150 R E V SCI A5 j REVOLUTIONARY SCIENCE 7 When used in higher temperatures the IncuCount may be uncomfortable to the touch When removing the IncuCount from the incubator it is recommended to use temperature resistant gloves or turn off the incubator and allow the IncuCount to cool to a comfortable temperature before removing it 8 Never attempt to modify the plugs or cords This may cause damage to the IncuCount or tablet cpu 9 Never immerse the Inc
4. Compatible with FDA 21 CFR part Il export as PDF 2 year repair or replacement Shafer Minnesota 55074 USA Customer Service Technical Assistance Fax Web site www revsci com 800 775 7942 651 674 3112 775 218 7015 E mail support revsci com REVOLUTIONARY SCIENCE REVOLUTIONARY SCIENCE IncuCount RS IC 150 R E VSCI Nw Hardware Installation Install hardware as shown in diagram below IncuCount Installation diagram micro USB Tablet CPU USB US B o Belkin w hub F 7 al USB flash drive ports flash drives not included IncuCount REVOLUTIONARY SCIENCE i SSL _ _ _ _ _EE IncuCount RS IC 150 R E V SCI J REVOLUTIONARY SCIENCE Wi Fi Setup To enable Wi Fi to receive automatic updates to the software swipe down on the wifi icon below in the upper right corner of the tablet screen Select the Wi Fl option Select your network and type in your network key and press Connect When connected to the internet through wi fi the tablet can receive updates as they become available REVOLUTIONARY SCIENCE A 10 IncuCount RS IC 150 R E VSCI J REVOLUTIONARY SCIENCE Automatic updates The engineers at Revolutionary Science are striving to make the feel and accuracy of the software better and better To this end we release updates from time to time As updates become available they can be installed
5. DF 99 Tap on File in the top menu and tap on Save PDF This brings up a Saved As menu Type in desired name for the file and tap enter REVOLUTIONARY SCIENCE 21 IncuCount RS IC 150 R E V SCI 5 j REVOLUTIONARY SCIENCE Antibiotic Reactions Measurement of Inhibition Zones Tap on Light Colonies or Dark Colonies on the top menu bar If disks on the screen appear blight in color then tap on Antibiotic Light If disks on the screen appear dark in color then tap on Antibiotic Dark Then tap on the Count button in the lower right side of the screen The software will identify the disks with green inhibition zones Then tap on Manual and then on Add Well This will allow the user to use pinch and zoom to manually adjust each green zone to proper diameter Manually Add or Delete Inhibition Zones To manually add a well tap on the Manual tab at the top and then on Add Well Then tap on the image where you want to add a new well The new well will show up as a green dot Note added wells will show up in the notes section on the right side of the screen To manually remove a well tap on the Manual tab at the top and then on Remove Well Then tap on the well you want to remove REVOLUTIONARY SCIENCE E 22 IncuCount RS IC 150 Q R E VSCI WV REVOLUTIONARY SCIENCE Help The help menu has three items About will give company name an
6. LUTIONARY SCIENCE Live Video Feed Preview When Preview is shown on top menu bar image displayed is live When Pause is shown on top menu bar image displayed is fixed The Pause mode is setting which all counting occurs Capturing Images To capture an image for counting or measuring an inhibition zone tap the CAPTURE button under the File dropdown menu Note Before capturing you may need to adjust the focus and lighting REVOLUTIONARY SCIENCE ee 0vOV SSSS HF 16 REVOLUTIONARY SCIENCE SCIENCE IncuCount RS IC 150 REVSCI R E VSCI Nw Colony Counting To count an image tap the COUNT button on the lower right side of screen The results will appear in the notes box on the right side of the screen In the image colonies will be colored green while those too large or small appear as red see Sensitivity and Colony Size sections on pages l6 and 7 Note Before counting you may need to adjust the sensitivity and or the counting region REVOLUTIONARY SCIENCE s 2 2 0 OOOO SSE_E_E_LELSESSSS 17 REVOLUTIONARY SCIENCE IncuCount RS IC 150 Q R E VSCI WwW Adjusting the Count Sensitivity To increase the counting sensitivity slide blue vertical sensitivity bar located be tween the image and notes section up To decrease the counting sensitivity slide blue vertical sensitivity bar down Note
7. d model information User Guide will open up this document Contact information for Revolutionary Science s Technical support Email support revsci com Telephone contact 651 674 3112 www revsci com Help Help About Us User Manual Appendix A Camera Settings Focus Adjust focus for better clarity Brightness Adjusting Brightness lightens or darkens the image Contrast Adjusting contrast heightens or lessens the difference between light and dark ar eas in the image Anti Flicker Voltage from an AC power supply oscillates at 50 or 60 Hertz Turning on this feature may help to account for that REVOLUTIONARY SCIENCE 23 Revolutionary Science Shafer MN USA
8. e will appear with the light gradient filtered out Uncheck the box and the calibration image will be removed REVOLUTIONARY SCIENCE ee 0vO OOO SSS HF 13 IncuCount RS IC 150 R E VSCI WA REVOLUTIONARY SCIENCE Setup Lighting Focusing Brightness and Contrast Controls Light Control The IncuCount comes equipped with an upper and a lower bank of LED lights To increase or decrease the intensity of these lights turn knob located in the back of the unit As viewed from the back camera end up the left knob controls the lower bank of lights and the right knob operates the upper bank Light Aperture Place the light aperture black ring into the unit on the light box Note The purpose of this important mechanism is two fold Centers the Petri dish in the camera s field of view 2 Blocks out excess light around the Petri dish providing the best possible view of the sample REVOLUTIONARY SCIENCE 14 REVOLUTIONARY SCIENCE IncuCount RS IC 150 S R E V SCI Nw Focusing Brightness and Contrast Controls Make sure camera mode is in preview will show as 3rd tab on top menu bar To adjust the image focus brightness or contrast tap on Camera Controls and then tap on Manual controls The controls will then appear on the right side of the screen Simply slide finger up or down for adjustment ess Contrast 60 Hz REVOLUTIONARY SCIENCE C 15 IncuCount RS IC 150 R E V SCI 5 j REVO
9. ort to use high quality durable parts to deliver the performance expected of instruments costing 2 to 3 times as much You may enjoy visiting our web site at www revsci com Please let us know what you think of our products positive or negative so we can continue to enhance and improve our products in the future Sincerely yours REVOLUTIONARY SCIENCE NOTE This manual contains important information safeguards and operating instructions for the operation of the REVOLUTIONARY SCIENCE model RS IC 150 IncuCount by Alternative Pioneering Research amp Development Inc APR amp D Inc REVOLUTIONARY SCIENCE IncuCount RS IC 150 Parts Checklist _ IncuCount _ Carrying case _ Light aperture ring _ Tablet cpu _ Manual Notes amp Service Record REVSCI REVSCI REVOLUTIONARY SCIENCE _ USB Belkin Hub _ Power OTG cable _ Detachable power supply w barrel connector _ Detachable power supply w USB connector For your own future reference and to expedite answers to your questions please complete the following information Date Purchased Serial Number Model Number Purchased From Your Notes REVOLUTIONARY SCIENCE IncuCount RS IC 150 R E REVSCI Nw REVOLUTIONARY REVOLUTIONARY SCIENCE Warranty Warranty Registration Please fill out this page or a copy of it and send it to the address below to validate your warranty Warranty Registration Card for the REVOLUTIONARY SCIENCE RS IC 150 IncuCoun
10. p on the Manual tab at the top and then on Add Colonies Then tap on the image where you want to add a new counted colony The new counted colonies will show up as a white dot as apposed to the green dots Note added colonies will show up as a positive figure under Colonies added in the notes section on the right side of the screen Manually remove colonies Tap on the Manual tab at the top and then on Remove Colonies Then tap on a green counted colony to remove it This will now show a red mark Note removed colonies will show up as a negative figure under Colonies added in the notes section on the right side of the screen Exclusion zone To exclude an area from counting tap on Manual on the top menu and then tap on Exclusion Zone Then tap around the region you want to exclude four sepa rate taps The highlighted exclusion zone area will then appear To remove an existing exclusion zone double tap inside of the zone REVOLUTIONARY SCIENCE O0G O SSS FH 20 IncuCount RS IC 150 REVSCI R E VSCI Nw REVOLUTIONARY SCIENCE SCIENCE Selecting a Previous Image Data Tap on File and then tap on Load Image The Load Image list of previous im ages will appear Select desired image and confirm Saving Data Tap on File and then tap on Capture Image This brings up a Saved As menu Type in desired name for the file and tap enter Export to P
11. seamlessly by swiping the notification bar upper left hand corner of the screen and clicking Update Available option The update will then download onto the tablet Install the up date when download is com plete 4 Colony Profile Setup Many of the settings can be programmed in and saved for each agar colony type being counted To make a colony profile simply adjust the camera settings p15 sensitivity settings p 18 and click Save Profile REVOLUTIONARY SCIENCE E 1 REVSCI A5 j REVOLUTIONARY SCIENCE IncuCount RS IC 150 Saving a Colony Profile To save the profile give the profile a name and click the enter button Any type a change is made to the profile it needs to be saved Making a Control Calibration Image If the lighting isn t even throughout the agar plate it may be necessary to make a calibration or control image to help filter out an unwanted light gradient To do this place a blank agar plate of the same type being counted into the IncuCount Make sure preview is on and adjust the camera and light settings to give the best image REVOLUTIONARY SCIENCE ee 0WQ SSS FF 12 REVOLUTIONARY SCIENCE IncuCount RS IC 150 R E VSCI Nw Tap Save in the Profile controls menu and give the image a name This image is saved in a calibration folder for future use Applying the Calibration Image To apply the calibration image check the apply checkbox The imag
12. t Please Print Date Purchased Serial Number Purchased From Please check one Company School Individual Name of Department or Institution Address Intended use Where did you hear of our product Comments Warranty Policy Your REVOLUTIONARY SCIENCE RS IC 150 IncuCount is warranted to be free from defects of material or workmanship under normal use for a period of two years from date of purchase If your RS IC 150 IncuCount proves to be defective within this warranty period APR amp D Inc will repair or replace your unit at our option This warranty will be void if malfunction is caused by accident misuse or negligence including tampering abuse or damage in transit This warranty excludes any relief for incidental or consequential damages REVOLUTIONARY SCIENCE REVOLUTIONARY REVOLUTIONARY SCIENCE IncuCount RS IC 150 R E REVSCI WA Safeguards amp Cautions To maximize the use of the IncuCount please follow the recommendations in this short list before using Examine carton and contents for possible damage to the product caused during shipping If damage is present contact carrier at once Failure to do so immediately may release the carrier from any liability of damage 2 Fill out the checklist page of instruction manual If something is missing please contact us 3 Carefully read this instruction manual before operating the IncuCount 4 Fill out warranty registration card and mail it to
13. uCount cord or plug in water or operate on wet surfaces 10 Never allow the cords to contact hot surfaces beyond 65 C Any slack in the cord should be wrapped up and held together with a band REVOLUTIONARY SCIENCE MMMmmm REVOLUTIONARY SCIENCE IncuCount RS IC 150 R E VSCI Nw Intended Use IncuCount RS IC 1 50 The Revolutionary Science IncuCount 150 can be used for the following purposes Colony Counting e Count colonies on Petri dishes e Multi color colony recognition 2 Measure the inhibition zones of antibiotic samples e Manual e Automatic 3 Monitor inside an incubated environment e Count colonies as they grow in real time e Measure inhibition zones as anti biotic reactions occur in real time e Email images REVOLUTIONARY SCIENCE SS 00 C C C CC SSF IncuCount RS IC 150 Specifications Model No Power requirements Net weight Dimensions Lights Camera CPU Petri dish size capacity Certifications Warranty Contact Information Revolutionary Science 17319 Lake Blvd S REVSCI REVOLUTIONARY SCIENCE RS IC 150 100 240 VAC 60 HZ 1 5 amps 5 Ib shipping weight 14 Ib 7 25 inches tall x 6 50 inches diameter High intensity LED lights top and bottom High resolution digital camera Carl Zeiss Optics Android based operating system Compatible with USB flash drive Up to 100 mm in size including 3M Petri Film UL approved LED lights power supply amp camera
Download Pdf Manuals
Related Search
Related Contents
3Com PLM Series Owner's Manual it-Switch - Inclusive Technology Sharp LC60LE550U 60" Full HD Black LED TV MARCHE PUBLIC DE TRAVAUX - Site officiel de la mairie de Wissous GARNIGR Samsung HM1700 Manual de Usuario Epson C42UX Basic manual 働く環境丶地球の環境丶 - 社団法人・日本厨房工業会 ND8422P - Vivotek Copyright © All rights reserved.