Home
User`s Manual
Contents
1. Controller Specifications One magnet rated 55 1 Ibs force 12 600 Gauss 20 000 operations 12 volts DC 3 amp 8 AA alkaline disposable batteries When used properly one set of batteries should yield hundreds of operations 30 feet in length 9 1 meters 5 conductor extra flexible PUR insulation Requires two hand operation The enable button must be depressed while depressing the ON or OFF buttons A programmable micro controller manages control inputs linear actuators and performs timing functions to protect the actuator in a stalled condition Intelligent H bridge motor drivers provide start stop braking actuator functions MarTek Ltd 4782 Chimney Drive Charleston WV 25302 1 800 248 4958 www chickenswitch com Chicken Switch is a Registered Trademark of MarTek Ltd US Patent 7 623 011 Copyright 2004 2013 MarTek Ltd All rights reserved User Manual GEPB2 Version 1 0
2. Operation is inhibited until batteries with an acceptable voltage level are installed The ENABLE button The Enable button must be continuously depressed in order to command the actuator Releasing the enable button has the same affect as releasing either the ON or OFF buttons both actuators will move to the retracted position Note If either of the actuators are held in the extended position for longer than approximately 3 seconds the actuator will de energize and will remain in extended position When the pushbutton or the enable button is released the actuator will retract 4 5 Hand Held Controller Cable Connector Power Switch Fuse Solid Yellow Ready Flashing Yellow Low Voltage Inhibit Press and Hold to ENABLE 5 0 Care and Storage 5 1 Cleaning the magnets Over a period of time the magnets may attract ferrous debris Exercise care to avoid setting the actuator where the magnets might attract debris If this does occur use a paper towel or nylon bristle brush to clean the face of the magnets Keeping the magnet faces clean ensures that maximum holding power is maintained 5 2 Storage Remove all batteries from the control station if the device will not be used for longer than 6 months Never store the batteries where the ambient temperature might exceed 110 F Avoid getting the unit wet or storing it in a high humidity location 6 0 Warranty MarTek Ltd guarantees
3. all products manufactured by MarTek Ltd only against defects in materials and or workmanship for a period of twelve 12 months commencing on the date the product is received by the customer THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE MarTek Ltd will at its option and its cost including shipping expenses for return and re delivery repair replace or refund the purchase price of any product manufactured by MarTek Ltd which has a defect in materials and or workmanship THIS IS CUSTOMER S EXCLUSIVE REMEDY FOR BREACH OF WARRANTY IN NO EVENT WILL MARTEK LTD S LIABILITY FOR DAMAGES WHETHER ARISING FROM BREACH OF CONTRACT OR WARRANTY NEGLIGENCE STRICT LIABILITY OR OTHERWISE EXCEED THE PURCHASE PRICE OF THE PRODUCT CONCERNED NOR WILL MARTEK LTD BE LIABLE FOR PUNITIVE INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES MarTek Ltd reserves the right to disallow warranty repairs if the unit has been disassembled or misused as determined by MarTek Ltd in good faith Please contact us at 800 248 4958 for a return authorization MarTek Ltd 4782 Chimney Drive Charleston WV 25302 1 304 965 9220 1 800 248 4958 7 0 MECHANICAL Holding magnets Projected life ELECTRICAL Operating voltage Fuse Power supply Control Cable
4. atteries Squeeze and lt 3 4 CAUTION Static Discharge Potential e To avoid possible damage to electronic components disconnect the control cable before replacing batteries To avoid possible damage to electronic components disconnect control cable before replacing batteries 4 0 Operation ALWAYS connect the control cable to the actuator BEFORE installing the Chicken Switch 4 1 Connecting the control cable D UT wf 1 Align the arrow on the cable end with the top of the receptacle 2 Push in and engage the threads on the coupling nut and turn clockwise 3 After one or two turns of the coupling nut push in on the cable end Repeat this until the connector is fully seated 4 Use a similar technique of turn stop and pull to disengage the cable ends 4 2 Sequence of Operation 1 Connect the control cable to the actuator 2 Plug the control cable into the control station 3 Follow steps on the following pages to attach the actuator 4 Ensure you are at a safe distance from the circuit breaker that is to be operated 5 Turn the Power Switch on top the controller to the ON position The amber LED should illuminate indicating the unit is ready 6 When ready to operate actuator press and hold the ENABLE button while depressing either the OFF or ON button for the desired operation Both buttons must be held depressed until the actuator has fully depressed the but
5. for evaluating each situation to determine if additional protective measures are needed A Electrical switching may present risk of serious injury or death This device should only be used by qualified persons after careful analysis of the hazards 2 0 Safety Information ALWAYS connect the control cable to the actuator BEFORE installing the Chicken Switch 2 1 Finger pinch points NEVER place your fingers in the area where the actuator extends when the control station is connected to the actuator The actuator could pinch your hand fingers against something nearby Also keep fingers clear of the bottom of the actuator near the magnets when the actuator is near a ferrous surface 2 2 Strong magnets The holding magnets are very strong Keep magnetically sensitive objects such as watches or computer disks away from the bottom of the actuator 3 0 3 1 3 2 Battery Requirements Eight 8 AA alkaline cells are required Carefully observe polarity when installing cells Only Alkaline batteries should be used Battery Life A set of fresh alkaline cells should give hundreds of operations Battery Replacement ALWAYS disconnect the control cable before replacing batteries to avoid possible static damage of the electronics A 9 Turn the control station upside down remove the endplate retaining knob Remove the endplate and slide the cover out as shown below 3 3 To connect disconnect b
6. tons 7 Release the ENABLE and OFF or ON buttons and the actuator will retract 4 3 Attaching and Removing the Actuator Make sure that both actuators are fully retracted by assuring the If plungers are plungers are protruding the not protruding breaker could more than inadvertently be 3 8 OPENED or CLOSED when the actuator is installed over the breaker Step 3 Align actuator guide into the recessed area on the breaker Step 5 While holding actuator firmly in place rotate Step 2 magnet lever to Make sure magnet lock magnet in lever is in the place retracted position Step 4 While holding actuator as shown with the actuator guide engaged in the recessed area on the breaker carefully push the actuator towards the breaker until the actuator on both sides near the magnet seats against the breaker door Step 6 Actuator should now be firmly held in place with magnet engaging the panel door Reverse the above steps to remove the actuator 4 4 The indicator lights amp controls NOTE Red and Green indicator lights only work when the ENABLE button is depressed GREEN indicates the actuator is being commanded to extend the ON actuator AIJ indicates the actuator is being commanded to extend the OFF actuator YELLOW indicates the hand held controller is powered and is ready Rapidly blinking YELLOW indicates the battery voltage with zero load has fallen to an unacceptable level
7. x CHICKEN SWITCH A Portable Actuator for Remotely Operating General Electric Power Break II Breakers Model GEPB 2 User s Manual 1 0 2 0 3 0 4 0 5 0 6 0 7 0 ae CHICKEN SWITCH User s Manual for Model GEPB 2 Arc blast Hazards Safety Information 2 1 Finger pinch points 2 2 Strong magnets Battery Information 3 0 Battery Requirements 3 1 Battery Life 3 2 Battery Replacement 3 3 Connecting Disconnecting Batteries 3 4 Static Discharge Potential Operation 4 1 Connecting the control cable 4 2 Sequence of operation 4 3 Attaching and removing the actuator 4 4 Indicator lights 4 5 Hand Held Controller Care and Storage 5 1 Cleaning debris from magnets 5 2 Storage Warranty Specifications 1 0 Arc blast Hazards The hazards associated with electrical arc blasts are well documented Studies conducted by numerous industries and professional organizations have sought to quantify the intensity of arc blast the risks to personnel and various methodologies for mitigating the risks Without doubt increasing the distance between the arc and a human is the single greatest favorable factor in reducing injuries The Chicken Switch is not a panacea but rather one more tool available for protecting workers while they are performing electrical switching Using a Chicken Switch may not negate the need for additional personal protective measures The user is ultimately responsible