1. To detach the coinbox Insert the key in the lock 1 and turn it 90 clockwise Push the release bolt 2 in the direction shown by the arrow and detach the coinbox by the han dle 3 As you do so support the coinbox from below with your free hand AN Remember that a full coinbox may weigh up to 40 kg To install the coinbox The coinbox can only be installed in the coin change machine when the status display 1 is green If this is not the case open the coinbox shift the locking lever on the inside of the cover and close the box again Push the coinbox as far as possible into the coin change machine Turn the key 1 90 counterclockwise and remove it from the lock 45 BEETLE iSCAN Scan amp Bag Hardware User Manual Opening closing the coinbox Remove the coinbox see section Detaching installing the coinbox To open the coinbox Insert the key in the lock 1 and turn it 90 clockwise Raise the cover of the coinbox towards the rear see arrow To close the coinbox Move the green locking lever 1 on the inside of the cover along the dotted line to position 2 Lower the cover 1 Check that the status display 2 is green If this is not the case check the position of the green locking lever on the inside of the cover Turn the key 3 90 counterclockwise and re move it from the lock Filling the coin hoppers e Activate the product specific software e Open
2. 2 coin hopper cover 1 hopper 1 5 Coin chute 1 3 fcon hopper cover 3 hopper 3 6 Lock for the lower level 40 BEETLE iSCAN Scan amp Bag Upper level pulled out 1 Coin hopper cover 5 hopper 5 Coin hopper cover 6 hopper 6 Hardware User Manual Coin hopper cover 4 hopper 4 4 con chute 2 41 BEETLE iSCAN Scan amp Bag Hardware User Manual Opening closing coin change machine CM IO S 6H L Pulling out pushing in the lower level Open the device To pull the component out Insert the key in the lock 1 and turn it 90 clock wise Pull the lower level out by the handle 2 as far as possible To push the component in Push the lower level in by the handle 2 as far as possible Turn the key 1 90 counterclockwise and remove it from the lock Pulling out pushing in the upper level Pull the lower level out see section Pulling out pushing in the lower level To pull the component out Pull the upper level out by the handle 1 as far as possible To push the component in Push the upper level in by the handle 1 as far as possible Opening closing coin change machine CM IO S 6H R Pulling out pushing in the lower level Open the device To pull the component out Insert the key in the lock 1 and turn it 90 clock wise Pull the lower level out by the handle 2 as far as possible 42 BEETLE iSCAN Scan amp Bag Hardware User Manual To
3. Scanner Maintenance Keep scanner windows clean This will improve productivity and reduce rescans Replace scanner glass when excessive scratches are evident Scanner Usage Minimize handling of heavy bulky products Leave these items in the cart and use an alternative entry method such as key entry of short PLUs or handheld scanning Regularly train cashiers in proper scanning methods and ergonomics principles such as Develop a smooth fluid motion during scanning sharing work equally between hands Use the entire hand for grasping and lifting items Since the scanner reads labels on all four sides plus the top and bottom there is no need to turn a bar code towards either of the scanner windows Develop efficient scanning motions not necessarily faster hand movements Simply slide the item across the scanner s horizontal window with as little orientation motion as necessary Leave items in an upright position do not lift and tilt Do not favor either the vertical or horizontal window slide items across the scanner in their natural orientations on the checkstand as much as possible Scanning Items To scan items slide or push them through the scan zone The scanner will work equally well with ei ther a left to right or right to left motion through the scan zone There is no need to reorient an item s bar code since the scanner can see the left right front and back side as well as the top and bottom of an item Pro
4. i banknotes must not be inserted since they may cause a banknote jam Insert the banknote at the center of the banknote input slot see illustration i Ensure that narrower banknotes e g 5 and 10 notes are positioned between the limit markings 1 and 2 Insert wider notes e g 20 and 50 notes above the limit markings Banknotes that are not centered on insertion are not recognized and will be rejected by the validation unit 66 BEETLE iSCAN Scan amp Bag Hardware User Manual Emptying the cassette Press release lever 1 for the cassette downwards Pull the cassette out by the handle 2 in the direc tion shown by the arrow Put the cassette down with the lock 1 facing up wards Insert the key in the lock 1 and turn it through 180 degrees Raise the top cover in the direction shown by the arrow Hold the pressure plate 1 securely and remove the banknotes 2 Move the pressure plate 1 carefully as far as pos sible in the direction shown by the arrow amp Close the top cover lock the cassette and remove the key from the lock Replace the cassette When inserting the cassette make sure that the bolts 1 at left and right on the cassette are posi tioned correctly in the in the mountings 2 in the housing 67 BEETLE iSCAN Scan amp Bag Hardware User Manual Description of the banknote path 1 Banknote input slot
5. 62 Modacar EEE EE 62 TEMP 62 Single Banknote AUtNENUCAlO esascs E E E N 63 EA e e TE EE Ne EE A AE EN E PE E A ME E SEE 64 SED NN 65 lasna banke up EPER 66 EMP NO TE e EN 67 Description ot Ihe banknote sen 68 Banknote denominations eee aranna rnaar Anara aar AAE DARALAR ACA nn AEn aranna nana 68 REMOVING a panknole AMS 70 Banknote jam in the validation unit eee eee eee eee 70 Banknote jam in the transport unit reedese aaa e eae na e saer iai 70 Banknote jam at the cassette crossover point ee eee ee 71 Cleaning and vates eT ale Luse See dene 72 VNR cacmenenect 72 Transpor UN ssassn 73 Approved cleaning materials ae 74 VS LOCK E 75 SS nn D NU 76 Fon VEN vaere A ctvbsuedncate TT MN 78 Pak VEN NS 78 APPENA EE NT EE NN KE ee 79 Ohanginguhne sate Code LE VP pos 79 Eee EEE EE EE EE EA EE ER 80 Programming NEAR 84 Programming Olt PG sears dietetic a chien tt enced inna hue lad wl arth asec A dire ularly 88 Manual POTET Jr SMS 90 BIOCK DEAN uvenn slngan 92 Environmental ReEqQUE NENNE 93 Certifications of the manufacturer e 94 Note on Radio Interference Suppression eee ee eee 94 FOO Class A Dean sendes 94 Reeycling ihe BEETLE ISCAN SCaNng amp e ee 95 BEETLE iSCAN Scan amp Bag Hardware User Manual Introduction The BEETLE iSCAN is a kiosk terminal which enables the user to carry out a complete purchase transaction without the need of a cashier At the BEETLE iSCAN the customer executes the sc
6. 654321 and turn the wheel to right 1 Turn the other wheel 2 until you can open the door of the safe Lock 39E Contact of the audit trail LT IL Generally Each pressing of a key is confirmed by a signal an acoustic signal and a LED flash A correct code entering is followed by double signal the wrong code is followed by triple signal Pauses longer than 10 sec will cause deleting of all previous entering and you have to start again Code entering Enter the seven unit numeric code or a word with 7 characters a Operation with parallel code a double signal is followed manager mode Manager code 1234567 80 BEETLE iSCAN Scan amp Bag b Operation with two codes must be programmed Opening Locking Wrong try penalty Change of code at the opened door Hardware User Manual Six unit numeric codes or words with six characters For opening two valid codes must be entered The code sequencing is arbitrary two of all valid codes can open Manager code 123456 and 654321 After entering of a correct code double signal the lock is ready to open for a time of 3 sec Turn the keypad by 90 TO THE RIGHT clockwise until it stops Swingbolt entry is fixed turn handle boltwork When during the ready time for opening 3 sec no opening is made then the lock will be automatically secured Turn the keypad back so that it is horizontal Swingbolt entry is fixe
7. 8 Cash out cassette 2 Status display 9 Cash out cassette 3 14 Hardware User Manual BEETLE iSCAN Scan amp Bag Function elements ss af NN V va E va 7 VASANTI yy Q O Oo C cC O ke D f o 2 wn gt amp Q 2 D f Cc Oo O N O Z be gt Q L D o 5 f S f ND gt OD xX Cc Oo sked O CC 3 LL al 15 BEETLE iSCAN Scan amp Bag Hardware User Manual Cash out cassette prame TTT Free space for validity identification Dispensing side 7 Locking unlocking lever optional 15 lock 8 Cassette lid Side of cassette handle 16 BEETLE iSCAN Scan amp Bag Hardware User Manual Reject retract cassette potene 1 T Locking unlocking lever optional lock raer 17 BEETLE iSCAN Scan amp Bag Hardware User Manual Removing the cassette Before cassettes can be removed the BEETLE iSCAN Scan amp Bag Terminal should be shut down To remove the cassettes from the CMD V4 Press the green releasing tab on the right side of the cassette 1 The released cassette is automatically pushed out of the dispenser by several centimeters Raise the cassette handle 2 and pull the cassette out of the CMD V4 by the handle 2 While pulling the cassette support it from underneath with your free hand Transporting the cassette i Make sure that the cassette s are not damaged or dropped during tra
8. Humidity 5 r h 1 g m 85 r h 25 g m 0 5 K min Temperature change 0 5 K min max 7 5K 30 min Transport conditions Ambient temperature 25 C 60 C Humidity 15 r h 1 g m 98 r h 32 g m Temperature change 25 C 25 C 93 BEETLE ISC AN Scan amp Bag Hardware User Manual Certifications of the manufacturer This device complies with the requirements of EEC directive 89 336 EEC with regard to Electromagnetic Compatibility and 73 23 EEG Low Voltage Directive Therefore you will find the CE mark on the device or on its packaging Devices without integrated UPS according class B Devices without UPS according class A Important Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note on Radio Interference Suppression All secondary appliances that are connected to an appliance must be equipped with radio interference suppression in accordance with EC directive 89 336 EEG Products that fulfill this requirement are accompanied by an appropriate manufacturers certificate bear the CE symbol or the radio protection symbol Products that do not fulfill these requirements may only be operated with specific permission of the relevant authorities FCC Class A Declaration This equipment has been tested and found to comply with the limits for a Class A digital device pur
9. If error message 23 does not disappear contact customer service If you can pull out the CMD V4 check the cash paths in the stacker and output transport see section Checking the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot Empty the reject compartment of the reject retract cassette See section Emptying the reject retract cassette Check the cash paths in the stacker see section Checking the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot Clear the cash paths see section Checking the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot Check the cash paths in the stacker and output transport see sec tion Checking the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot Shutter error Check the shutter Perform a reset using the function button Reject retract drive MA6 defective blocked lifting magnet Cash out photosensor cov ered manipulation Too many problems during dispensing from cassette x x 1 6 28 Check the cash paths in the output transport see section Checking the cash paths Perform a reset using the function button Bundle rejects can be caused by extremely deformed banknotes or banknotes that are extracted in an uncontrolled way or by problems with the photosensors This
10. The CMD s controller status messages are listed in the following table The status messages their meanings and the remedies you must employ are explained so that you can eliminate CMD V4 prob lems If contrary to expectations you are unable to fix the problem you should contact the Service The two digit codes indicate the following error messages Meaning Remedy O OoOO off No power supply Switch on the device Start up after RESET or Wait until start up is complete electronics self test D mr No error Software faulty Switch the device off and on Communication problem with Perform a reset using the function button If error message 05 does ChipCard controller not disappear contact customer service Communication problem with Perform a reset using the function button If error message 06 does ChipCard or wrong Chip not disappear contact customer service Card inserted ChipCard number not 226 0PR Missing software download Perform a reset using the function button If error message 11 does not disappear contact customer service Safety switch open Insert the CMD V4 Device disable present Remove banknote bundles from the CMD V4 Reset the device lock using the product specific software see chap ter Basic Operation section Calling the product specific software CMD V4 minimum configura Insert and log in cassette reject and cash out cassette required tion is missing BC
11. by the arrow Replace the cassette When inserting the cassette make sure that the bolts 1 at left and right on the cassette are positioned correctly in the mountings 2 of the housing 71 BEETLE iSCAN Scan amp Bag Hardware User Manual Cleaning and maintenance AN You must switch the system off before cleaning the unit The following parts of the single banknote authenticator should be serviced and cleaned at the speci fied intervals You must also comply with the following No cleansing agents must be allowed to penetrate the inside of the single banknote authenticator Only use the cleansing agents specified Do not use alcohol or thinners Validation unit Cleaning interval Depends on degree of soiling Cleansing agent Compressed air Lint free cloth dampened slightly with water e g dust cloth in profes sional cleaning set for IT devices e Switch the system off Press tabs 1 and 2 forwards at the same time see arrow and raise the validation unit 3 at the rear Clean sensors 1 to 9 in the movable part of the vali dation unit with a lint free cloth 72 BEETLE iSCAN Scan amp Bag Hardware User Manual Clean sensors 1 to 7 in the fixed part of the validation unit with a lint free cloth Clean the area round the validation unit with compressed air Transport unit Cleaning interval Depends on degree of soiling Cleansing agent Compressed air e Switch the syst
12. comes into contact with your eyes consult a medical doctor im mediately Inside the display the high voltage needed for backlighting the LCD display is generated by the in verter High Voltage Before opening the device make sure that the device is disconnected from the main power supply Opening of the device only by authorized personnel Note on Laser The PSC 850x Scanner Scale is not intended for long term viewing of direct laser light However the unit is safe if used as intended This scanner meets the following laser LED power requirements Class lla Laser Avoid long term viewing of direct laser light Class 1 EN60 825 European Norm BEETLE iSCAN Scan amp Bag Hardware User Manual BEETLE iSCAN Scan amp Bag Components FEN S 4 H K dP s L E ve Er gd Ce IN F Sa Yai Se 3 A L CE S 9 3 04 E i FS oF gt ng EMR a r j ore be ERE eee L ytt AG art md EEE 1 Screen 15 CoinOQutput 9 ReceiptPrinter 2 Scanner Scale 6 Note Input 10 PoleLight Note Output Shutter 4 Coin input 8 Swipe Card Reader 12 Shelf for Baskes op pp fele BEETLE iSCAN Scan amp Bag Hardware User Manual Pulling out the Scanner Carriage Switch off the system Unlock the the scanner carriage arrow BEETLE M II AC Adapter 3 Shutter 4 Display Scanner 3 Waiters Lock Key Lock pp BEETLE SCAN Scan amp Bag Hardware User Manual Scanner Scale
13. is the entire company Follow your local regulations on the disposal of toxic waste such as the system ribbons Your Wincor Nixdorf vendor will answer any questions you have concerning returns recycling and disposal of our products 95 Wincor Nixdorf International GmbH D 33094 Paderborn
14. jam If the problem cannot be remedied please notify customer service Empty the cassette see the operating manual If the problem cannot be remedied please notify customer service Wait until the check is complete Check whether the validation unit and the transport unit are correctly closed If the problem cannot be remedied please notify customer service Remove the banknote jam see section Removing a banknote jam If the problem cannot be remedied please notify customer service 69 BEETLE iSCAN Scan amp Bag Hardware User Manual Removing a banknote jam Banknote jam in the validation unit Press tabs 1 and 2 forwards at the same time see arrow and raise the validation unit 3 at the rear Remove the jammed banknote carefully in the di rection shown by the arrow Lower the validation unit until it locks into place Banknote jam in the transport unit Pull release lever 1 upwards See arrow and raise the transport unit 2 at the rear 70 BEETLE iSCAN Scan amp Bag Hardware User Manual Remove the jammed banknote carefully in the direction shown by the arrow Lower the transport unit until it locks into place Banknote jam at the cassette crossover point Press the release lever 1 for the cassette down wards Pull the cassette out by the handle 2 in the direc tion shown by the arrow Remove the jammed banknote carefully in the direction shown
15. push the component in Push the lower level in by the handle 2 as far as possible Turn the key 1 90 counterclockwise and remove it from the lock Pulling out pushing in the upper level Pull the lower level out To pull the component out Pull the upper level out by the handle 1 as far as possible To push the component in Push the upper level in by the handle 1 as far as possible Detaching installing the coin hopper cover The covers of the coin hoppers are detached in the same way for both versions of the coin change machine Pull the lower level or the upper level out Place one finger in the cover openings 1 and 2 and detach it upwards Reinstall the cover by following the same steps in reverse order 43 BEETLE iSCAN Scan amp Bag Hardware User Manual Detaching installing the level cover i The covers of the lower and upper levels are detached in the same way for both versions of the coin change machine Pull the lower level or the upper level out Grasp the sides of the cover 1 and detach it up wards See arrows When installing the cover make sure that the tabs 1 and 2 of the cover 3 are pushed correctly over the edge of the plate See arrows 44 BEETLE iSCAN Scan amp Bag Hardware User Manual Detaching installing the coinbox i The coinbox is detached and installed in the same way for both versions of the coin change machine Open the device
16. storm data cables should not be plugged in or unplugged e Keep the device away from vibrations dust humidity and heat e The BEETLE iSCAN is the result of modern technical innovation Therefore please also ensure that the BEETLE iSCAN is operated under modern building and technical conditions in order to ensure flawless and efficient operation The appliance and other information technology hardware should only be connected to electrical supply networks with a separate protective earth wire PE This type of electrical supply network is referred to as a TN S network Do not use PEN conduc tors Also follow the recommendations set forth in DIN VDE 0100 Part 540 Appendix C2 This will help prevent malfunctions e Always keep the ventilation slots free of obstruction to ensure adequate air circulation and avoid overheating e Transport the appliance only in its original packaging to protect against knocks and bumps BEETLE iSCAN Scan amp Bag Hardware User Manual Cleaning Instructions Always turn off the system before cleaning If liquids were spilled over your System switch off the system and disconnect the power plug Dry the device with a cloth and leave it switched off for a while LCD Displays If the display element is damaged and the liquid crystal solution leaks out onto your hands or cloth ing please wash your hands or clothing immediately under running water for at least 15 minutes using soap or alcohol If the liquid
17. the cash out cassette To ensure error free dispensing fill the cash out cassette only with intact and carefully prepared banknote bundles which only contain notes of the same value Preparing the banknote bundles Check the banknotes for damages before you put them into the cash out cassettes Sort out the damaged banknotes and or remove clips needles or other foreign objects The following banknotes should be rejected torn glued folded creased stapled or clipped banknotes If you use new bank notes bank note bundles you must separate the bank notes at the cutting edges Carefully fan the bank note bundles and bend and twist them repeatedly in various direc tions 20 BEETLE iSCAN Scan amp Bag Hardware User Manual Inserting banknote bundles i Also follow the instructions for filling the dispenser cassette on the inside of the cas sette cover General instructions for filling the cassette Remove any existing bank wrappers made of paper plastic or rubber before inserting the banknote bundle You should always insert the banknote bun dles into the cash out cassette so that the silver stripes or other raised embossing of the individual bundles are alternately pointing to the left and to the right 21 BEETLE iSCAN Scan amp Bag New and used banknote bundles 22 Hardware User Manual If you use new and used banknote bundles in one cassette always insert the bundles with the used bank
18. the device e Pull the lower or upper level e Remove the cover from the hopper you want to e Fill the hoppers with the specified coin type i When filling the coin hopper make sure that no foreign objects or coin types that do not comply with the configuration of the hopper you are filling are allowed to enter the hop per If you fill an excessively large coin type in a coin hopper by mistake you have to de tach the hopper see section Detaching installing the coin hopper and remove the coins from the hopper 46 BEETLE iSCAN Scan amp Bag Hardware User Manual The currency that is set and the coin types as signed to the individual hoppers must be noted Hopperbestiickungen der Munzauszahlfunktion Hopper configuration of the coin out function on the hopper configuration label Wahrung Currency The numbers of the individual coin hoppers and the currency assigned to the individual hoppers coin type are indicated on the label affixed to each hopper cover e Reinstall the cover see section Detaching installing the coin hopper cover and as applicable push either the upper or the lower level back into the device e Close the device e Deactivate the product specific software Detaching installing coin hoppers i The coin hoppers are removed in the same way for both versions of the coin change ma chine Before detaching coin magazine 2 you must detach coin magazine 1 from the lower level B
19. the service and diagnostics panel 00 00 01 General controller error Please contact the Service department 01 XX UU Coin checker error Check the coin checker and remove any jammed coins If it is not possible to remedy the error please contact the Service department 03 xx On Error in coin hopper n n 1 6 03 01 On Coin jammed at coin output Eliminate the coin jam position of hopper n If it is not possible to remedy the error please contact the Service department Coin jammed at coin output Eliminate the coin jam position of hopper n If it is not possible to remedy the error please contact the Service department Motor of coin hopper n is Visually inspect the coin hopper and eliminate blocked the cause of the blockage If it is not possible to remedy the error please contact the Service department Motor error in coin hopper n Please contact the Service department Coin sensor error in coin hopper Please contact the Service department n Coin hopper n is empty Fill coin hopper n Coinbox is not available Install the coinbox If it is not possible to remedy the error please contact the Service department Coinbox is full Empty the coinbox If it is not possible to remedy the error please contact the Service department Error on coin checker trouble Please contact the Service department shooting motor home position not reached Maintenance Visually inspect the coin hoppers and remove any
20. to the probe and transmits the data by an electrical RS232 interface The readout of the data may be integrated easily in a software application 19 BEETLE iSCAN Scan amp Bag Hardware User Manual BEETLE M II The BEETLE M II controls several devices in the BEETLE ISCAN Scan amp Bag such like the printer and the scanner The BEETLE M II is located behind the scanner carriage Switch off the system Open the scanner carriage completely page 22 Loosen the wheel see arrow which locks the carrier of the BEETLE M II and pull the carrier out completely In the following you see an overview to it s functions and components 76 BEETLE iSCAN Scan amp Bag Hardware User Manual Front view Floppy Disk optional CD ROM 3 ON OFF Button 4 USB 2x 17 BEETLE iSCAN Scan amp Bag Hardware User Manual Inside view Floppy Disk optional CD ROM 3 Hard Disk Power Supply elmer la Motherboard with Processor Back view USB Hub Rd a EI Ea E a 0 Scale COM Scale I F VGA 4 Display B o COMB o 100 120 V 2 A max DC24V CASHDR EE 200 240 V 1 A max LPT1 UU jo Me p e O ET LAN SPK MIC KYBD COM1 COM2 USB 78 BEETLE iSCAN Scan amp Bag Appendix Changing the Safe Code LG 39E Unlock the door and open it Hardware User Manual 79 BEETLE iSCAN Scan amp Bag Hardware User Manual Enter the pin Manager Code 123456 and
21. two characters The first place in this group of characters is the code length the second one is the program number Program 0 Manager mode operation with parallel code Program 1 Manager mode with delay override Program 2 Operation with two codes Program 3 Two code operation with delay override Program 4 Manager mode with alarm Program 5 Manager mode with alarm and with delay override Program 6 Two code operation with alarm Program 7 Two code operation alarm and delay override Enter the manager code 555555 and keep pressed the last number until the double signal LED is on is repeated and enter 8 Then enter the group of two characters made of code length and program number double sig nal and repeat the enter of the group for confirmation double signal In case of the seven unit codes the manager code is 7 x 5 BEETLE iSCAN Scan amp Bag Enable user function 1 Program freeze Reset to the Factory Mode Hardware User Manual Enter the manager code and keep pressed the last number until the double signal LED is on is repeated then press 1 and the user ID No 1 9 and enter the code two times The disabled users cannot be enabled after the change of the manager code With the change of the manager code the program is frozen and it can be changed only with resetting and with a new programming Disconnect the lock from the power supply for ca 3 minut
22. 2 Validation unit 3 Transport unit 4 Cash cassette The banknote you insert in the banknote input slot is conveyed to the validation unit Counterfeit notes and notes that are not identified are returned to the banknote input slot for removal Banknotes that are identified as genuine are conveyed to the cassette by the transport unit Banknote denominations If the national currency changes or if a new note is issued e g a new denomination or new banknote design the currency file in the single banknote authenticator will need to be updated by customer service 68 BEETLE iSCAN Scan amp Bag Troubleshooting Problem The inserted banknote is always returned to output The banknote is not re tracted Undefined motor movements Undefined motor movements The sensors in the vali dation unit are dirty The validation unit does not recognize the bank note e g because a bank note denomination has changed A banknote jam has occurred The cassette is full The status of the single banknote authenticator is being checked The validation unit or the transport unit is not correctly closed Banknote jam at cross over to cassette Hardware User Manual Clean the sensors in the validation unit see section Cleaning and maintenance If the problem cannot be eliminated please notify customer service Please notify customer service Eliminate the banknote jam see section Removing a banknote
23. Banknotes jammed during Check the cash paths in the stacker in the area of the stacker dispensing wheels and in the dispenser modules see section Checking the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot If error message 18 does not disappear contact customer service Clamp transport defective Check the cash paths in the output transport See section Checking blocked the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot Single reject switch Check the cash paths in the output transport See section Checking MA2 SM1 defective the cash paths blocked Move the CMD V4 in the safe to the cash out position and wait for the system to boot 2 BEETLE iSCAN Scan amp Bag Hardware User Manual Faulty measuring station DDU Photosensor amplifier faulty or photosensor initialization unsuccessful Routing disk DCM2 SM3 defective blocking Dispensing drive DCM 1 defective blocked Stacker wheel drive SM 9 defect blocked Clear the cash paths see section Checking the cash paths Move the CMD V4 in the safe to the cash out position and wait for the system to boot If error message 22 does not disappear perform a reset using the function button If you do this three times without success contact customer service If you cannot pull out CMD V4 perform a reset using the function button
24. Rail e Once weighed items are in place enter PLU price Look Up data as described in your POS system instructions Item weight is displayed on the Remote Display and or the host display e Remove the item from the weigh platter i It is important that items rest entirely on the platter for their full weight to be accurately recorded BEETLE iISCAN Scan amp Bag Hardware User Manual Printer TP07c Turn the key to the right and swing the door open BEETLE iSCAN Scan amp Bag Hardware User Manual The printer is located on the left side see arrow Grab the lever arrow and pull out the printer completely BEETLE SCAN Scan amp Bag Hardware User Manual Changing the paper roll Removing the paper roll Cut off the paper at the paper support Lift the paper roll with the paper roll holder upwards out of the printer Use the LINE FEED button to remove the remaining paper Setting the paper roll core diameter When starting operation of the device or when changing the paper roll diameter check whether the selection switch for the paper near end adjustment is set to the correct position A1 A2A3 B3 B2B1 Choose the roll holder which fits to the paper roll core 10 BEETLE iSCAN Scan amp Bag Hardware User Manual Holder for 25mm core diameter identifier 2 Holder for 40mm core diameter identifier 3 Inserting the paper roll Push the paper roll holder into the paper roll core 9 Ins
25. WINCOR NIXDORF BEETLE ISCAN Scan amp Bag Hardware User Manual May 2006 All product names mentioned in this document are registered trademarks Copyright O Wincor Nixdorf International GmbH 2006 All rights including the rights to the translation reprinting transmission or copying by any means in whole or in part are re served Offenders will be liable for damages All rights including rights resulting from a patent grant or registration of a utility or design are reserved Contents gl dele PL eg EE EEE EEE EEE EE EE 1 Te LE eie 0 NE EE NT ren ene ee 2 NOTE onm LARA 3 BEETLE ISGAN Scans Bad COMPOS ansees eee 4 Pull Our ihe Scammer CATE arver 5 SCAMMER SA TTT 6 Scammer M ne Aarre 6 Scanner USAGE a L TAT 6 Scan LENS av 6 Proper scanning TEA NIUE ae 6 Proper Weighing Technique aure de a a a a AE 7 FINEP ERO ee 8 pango Me PE Lavere O sient apeasnc auneda teen 10 Removing the P DE LOM soninn a a a a 10 Setting the paper roll core diameter eee eee 10 HSE NE PPT kassene ele die 11 Cash Media Dispenser Vertical Cash Out eee 12 Modules and function elements sss sees eee eee eee eee 14 FUNCIONSENENS eee Leer 15 GN OUST 16 Ree retract ASSEN 17 MeEMOVING aie ae au Madre 18 Transporting the CASS Bua eee 18 Opening the ASS Ear 18 Emptying the reject retract Cassette eee 19 FINE ThE cashout cas ellena a a aa 20 Preparing the banknote bundles sse eee eee 20 Inserting banknote bundles esse eee 21 Possible
26. an ning bagging and paying of the item completely on his own Each BEETLE ISCAN kiosk terminal is connected to an attendant station This is a POS system which controls all connected BEETLE iSCAN terminals and which is supervised by a human atten dant thus ensuring that the customer will receive human support in case problems should occur at the BEETLE iSCAN kiosk terminal during transaction It is possible to connect up to 20 lanes to one attendant station Prior to the installation of BEETLE iSCAN the site has to be prepared carefully and according to spe cific requirements These requirements might vary considerably depending on the customers re quirements as well as on the conditions given at the respective site In order to avoid deficiencies that may be difficult to detect and or to correct after the installation the preparatory work is of considerable importance As BEETLE ISC AN consists of separate pieces that may be combined in various configurations it is an absolute pre requisite that you will determine the equipment to be installed at your site According to this installing information the site preparation can respectively will have to proceed BEETLE SCAN Scan amp Bag Hardware User Manual Safety Instructions Appliances supplied by Wincor Nixdorf International GmbH comply with the respective safety regula tions for data processing installations and information technology installations including electrical
27. ard 2 20 mm 4 5 6 long 2 euro 52 BEETLE iSCAN Scan amp Bag Hardware User Manual Great Britain GBP Standard configuration factory setting for British currency s 0 01 GBP 8 compartments red Standard long 0 02 GBP 8 compartments red Standard long 0 10 GBP 8 compartments red Standard long Additional configuration options To be dispensed from hopper no X with the configuration Separator disk Blade Currency coin Coin dimen 8 cmp red 7 cmp black 12 cmp white 18 30 mm 1 2 20 32 mm 1 2 12 20 mm 1 2 Standard long Standard long Standard long Standard long Standard long 1 2 4 6 0 01 GBP 20 33 mm 1 69 mm 0 02 GBP 26 00 mm 2 00 mm 172 37 4 5 6 0 05 GBP 18 00 mm 1 70 mm 0 10 GBP 24 50 mm 1 84 mm 0 20 GBP 21 40 mm 1 70 mm 0 50 GBP 27 30 mm 1 78 mm 1 00 GBP 22 50 mm 3 10 mm 2 00 GBP 28 40 mm 2 60 mm 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 Standard long Standard long 1 2 3 4 5 6 53 BEETLE iSCAN Scan amp Bag Hardware User Manual Description of the coin paths Payment 2 loa output position coin return a coin output position coinbox The coins that are inserted in the coin slot roll through the coin funnel into the coin checker Coins that are not genuine currency or not recognized as coins are routed to the coin return box via the coin output position coin return box Co
28. bers mean is described in the following table To start a particular sequence release the key when the status display shows the relevant value i The functions described in the following sections can be performed only when the safety switch is closed i e the CMD V4 is in cash out position Functions 2 and 3 may be started only from normal operation display 00 or 14 or when all transport paths are guaranteed to be clear Display Function Function description 32 BEETLE iSCAN Scan amp Bag Hardware User Manual Normal operation RESET The CMD V4 is powered up while is displayed on the status indicator for approx 10 seconds If an error is detected which pre vents or endangers the operability of the CMD V4 soiled photosen sors the relevant error or a warning is displayed on the status dis play This test function is identical to the power up test when the CMD V4 is pushed into the dispensing position closing the safety switch Overall test In this test all mechanical CMD V4 components are operated one RESET after the other If an error is detected it is displayed on the status display The lifting magnets for the single reject switch and retaining shafts and the electromagnetic clutch can only be subjected to a visual function check in this case If no errors are detected during the test a RESET is then carried out Test dis With this test the cash paths and the dispensing function of all in p
29. coin types that do not comply with the configuration for the hopper that is to be filled also remove any foreign objects BEETLE iSCAN Scan amp Bag Hardware User Manual CMD V4 Shutter Switch off the system Unlock the scanner carriage and open it completely page 5 in hutter i 4 Structure The shutter locks the cash output tray of the cash media dispenser CMD V4 It includes the following assemblies Drive mechanism with stepper motor gears locking mechanism and two hybrid photosensors GL 10 and GL 11 for monitoring the position of the shutter 1 photosensor LS 28 for providing a cash bundle for output 1 photosensor LS 27 for monitoring removal of cash 1 Interface board for controlling the shutter 59 BEETLE iSCAN Scan amp Bag Hardware User Manual Rear view of frontload version 60 BEETLE iSCAN Scan amp Bag Hardware User Manual Function The shutter is controlled via the firmware of the CMD V4 controller and is initiated by the application software Shutter and drive mechanism are directly connected The rotation of a cam disk makes the shutter open and close The stepper motor has low motive force so there is no risk of injury when the shutter is closed The shutter is locked automatically when it is completely closed Cash removal If the application sends an order to dispense cash the shutter is first opened completely via the firm ware After the banknotes have been tra
30. ct specific software see chapter Basic Operation sec tion Calling the product specific software Checking the stacker and output transport i Do not try to open the clamp by force you could damage it Stacker wheel area Check the area around the vertical transport and if necessary remove any notes 30 BEETLE iSCAN Scan amp Bag Hardware User Manual Single reject area i The function of the single reject depends on the individual configuration Press the green release levers 1 out wards and pull the flap 2 forwards Check the area and if necessary remove the banknotes 3 31 BEETLE iSCAN Scan amp Bag Hardware User Manual Gear tracks of the stacker and output transport If the clamp has come to a standstill at a position outside the stacking position you XV may need to check and clean the gear tracks 1 Check the photosensors in the shutter area After checking the cash paths proceed as follows After checking the cash paths push the CMD V4 by the green release lever back into the safe as far as possible Close the safe door Function test Press the function pushbutton on the CMD V4 controller to start tests and to reset the CMD V4 To start a test function the CMD V4 must be in normal operating mode 00 or 14 is then shown on the status display When you press and hold the function key 00 1 2 3 4 and 5 are shown on the status display What these num
31. d turn handle boltwork Check the lock to be locked After 4 successive wrong code enters the lock will be cut off for 5 minutes then it will be cut off already after 2 wrong tries During this wrong try penalty the LED is flashing each 10 sec The key pressing is refused with a triple signal The user can change its code by himself anytime a Enter the code and keep pressed the last number until the double signal LED is on is repeated press the 0 and enter the new code double signal enter the new code once more for its confirmation double signal b Press 0 for seven times when operating with two codes six times O enter the old code and then two times the new code always followed by double signal The new code is now active In case of wrong entries or pauses during entering the code longer than 10 sec remains valid the old code When the new code would not be accepted triple signal then it is too similar to the code already stored Always enter the new code with the door opened 81 BEETLE SCAN Scan amp Bag Silent alarm must be programmed Time delay for opening must be programmed Time delay override must be programmed Power supply Safety notice 82 Hardware User Manual In case of blackmailing the silent alarm can be started so that you enter the last code number 1 e g the last number is 9 and the alarm is started with the number 0 instead of 9 The lock functio
32. deformation of banknotes eee 23 Inserting the cassette eee ee eee eee 25 CIOSING TNE CASS CMC eee 25 INSESMING ING CASS EE EEE EE EE 26 RT nT E Te ae 26 Status messages CMD controller see eee 27 GINEGCKING IMG Note pats eosar a ledene 29 CON CRINGE MACN ve 34 Control sran aa a R EN 36 Coin change machine CM IO S 6H L e eee 36 Coin change machine CM IO S 6H HI sees 39 Opening closing coin change machine CM IO S 6H L eee 42 Opening closing coin change machine CM IO S 6H RI sse eee eee 42 Detaching installing the coin hopper COVEL esse eee eee ee eee 43 Detaching installing the level COVED sse eee eee 44 Detaching installing the Coinbox SEERE EE EE ER 45 Opening CIOSING the EON LA 46 FAGE COMM ODD S eisa A R R AV O 46 Detacning 7 installing Coin NOPPES T 47 SREE alU ae eee 49 Coin change machine CM IO S 6H L sese 49 Coin change machine CM IO S 6H R esse 50 Overview of possible hopper configuratiOns rrrrrrrrrrnnnnnrrarrrvrrrnnnnnnnrrrnnrrrnnnnennsrrnnnnnnnnnsnsssnnnnnnnnne 51 sal 8 0 0 2 10 0 NE EE KL ER NN ME 52 GEA Ban GBP avvv42rsRR GE 53 DESCNPNON Oh ING GOIN PS Har 54 PAMELA 54 DISPENSNA SMAA saorsa a Rs Sebi Outs ib a 55 Coin change machine CM 1O S 6H R airna a a 56 Eror messages ca cden a a E 58 MEAN NN aaaea a A eee ree 58 E IK S NE 59 STUEN 59 Rear VIGW of frontload version senian etikett 60 Fulda 61 L PTT ona et 61 Frode Bure 61 Bank Note VA saa
33. e and can be opened with the key 1 The programming will be effective when the factory mode is finished keep pressed 0 until the double signal is repeated and enter the manager code The program must be frozen by the change of manager code The lock is ready for operation BEETLE iSCAN Scan amp Bag Hardware User Manual Reset to the Factory Mode When the programs shall be changed the reset with the Re set Box is necessary for a new programming Disconnect the lock from the power supply for ca 3 minutes remove the battery and insert the Reset Box into the BAT inlet of the lock The lock is in the Factory Mode opening with key 1 The Reset Box must be connected to a 9V ALKALINE bat tery Safety notice Do not assign code to the users of no use for the time being Manager can do this later 89 BEETLE SCAN Scan amp Bag Manual programming Factory Mode Pre Setup mode Exit the Factory Mode Hardware User Manual The lock may be installed in the factory mode It is opened when pressing the key 1 and it sends an alarm Thus the simple and flexible storing is reached and the sim ple operation during installation is secured Keep pressed the key 0 until the double signal is repeated Now the manager code is 555555 Code length and program selection The code length and program selection are made with the Programming function 8 90 function 8 and a group of
34. e signal LED is on is repeated press the 0 and enter the new code double signal enter the new code once more for confirmation double signal The new code is now active In case of wrong entries or pauses during entering the code longer than 10 sec remains valid the old code remains valid When the new code is not accepted triple signal it is too similar to the code already stored Enter a new code Enter the manager code and keep pressed the last number until the double signal LED is on is repeated press the 1 double signal enter the user ID No 1 9 e g 2 double signal enter the user code double signal enter the user code once more for confir mation double signal When a triple signal is followed then the code confirmation was wrong or the code is too similar to the already stored code Enter a new code BEETLE iSCAN Scan amp Bag C Disable user function 2 D Remove user function 3 E User status inquiry function 7 Hardware User Manual Enter the manager code and keep pressed the last number until the double signal LED is on is repeated press the 2 double signal and enter the user ID Nr e g 2 single signal The user ID Nr 2 is now disabled for such time period until again enabled with the function 1 and the ID Nr 2 Enter the manager code and keep pressed the last number until the double signal LED is on is repeated press the 3 d
35. efore detaching coin magazine 4 you must detach coin magazine 6 from the upper level See section Controls for the arrangement of the coin hoppers e Turn the device off see the operating manual for the system e Pull the lower or upper level out See section Opening closing coin change machine CM IO S 6H e Remove the cover from the level containing the coin magazine you need to detach see section Detaching inserting the level cover e Remove the coin chute if necessary see section Coin chute Note that the locking tabs can break off easily 47 BEETLE iISCAN Scan amp Bag Hardware User Manual Press the locking tabs 1 and 2 inwards on both sides of the coin hopper raise the coin hopper slightly at the rear 3 and detach it towards the rear i Note the position of the connector mark it if necessary Unplug the connector 1 from the coin hopper Reinstall it by following the same steps in reverse order Never use force when plugging in the connector Make sure that the connector is plugged in at the right position The catches 1 to 3 of the coin hopper must be inserted correctly in the openings 1 to 3 of the base plate 48 BEETLE iSCAN Scan amp Bag Hardware User Manual Coin chute Coin change machine CM IO S 6H L i Coin chute 1 on the lower level and coin chute 2 on the upper level are detached in the same way e Turn the device off see t
36. em off Pull the release lever 1 upwards see arrow and raise the transport unit 2 at the rear Clean the area round the transport unit with compressed air 13 BEETLE SCAN Scan amp Bag Hardware User Manual Approved cleaning materials You can order the items listed below directly from Wincor Nixdorf Fax 49 0 5251 693 4888 E mail serviceslogistics wincor nixdorf com Internet www wincor nixdorf com mediaservice Notes on using cleaning materials i Please note the manufacturer s specifications on the packaging and on the information sheet included in the packaging The product may be damaged or soiled if materials are used that are not approved or if they are used improperly General purpose cleaning materials Wincor Nixdorf Elix cleaning set contents 01750078103 100 ml plastic cleaner in pump bottle 100 ml screen cleaner in pump bottle 50 dust cloths 10 keyboard swabs for hard to access spots Compressed air duster with extension hose 01770007430 74 BEETLE iSCAN Scan amp Bag Hardware User Manual Waiters Lock Each transaction is correctly assigned to the personell by using the magnetic key The magnetic keys are available in 10 different colors The magnet keys are waterproof shatterproof and by the 16 digit key number also safe for clear iden tification The operation of the system is very simple the key is placed onto the magnetic probe see figure The key is held magnetically
37. ensing serted and filled cassettes are checked First a banknote is extracted RESET from the top cassette and transported via the single reject switch to the reject compartment Then one banknote is extracted from each cassette transported by the clamp to the waiting position the shut ter remains closed and then to the reject compartment If an error occurs it is displayed on the status display If no errors are detected during the function a RESET is then carried out Display The version number is displayed in alternating mode firmware version Example In the case of the module label SMODS 011214 1000 CMD V4 0 BIN version number 1000 of the first release on December 14 2001 is displayed as follows 10 for 2 seconds basic release upgrade release 00 for 1 second upgrade expansion update error elimination After nine attempts the device returns to normal mode Statistics The resettable counters are reset to 0 and the current date of the counter real time clock is saved reset pf i 33 BEETLE iSCAN Scan amp Bag Hardware User Manual Coin Change Machine Switch off the system and unlock the front door CARD PAYMENT RR gt Q NOTE IN ee C i VU x U ra Open the door upwards 34 BEETLE iSCAN Scan amp Bag Hardware User Manual Coin change machine CM IO S 6H is a component that implements a payment function with separate stocks of coins for deposit and di
38. error can be ignored the first time it occurs warning If the error keeps occurring please proceed as follows Remove the cassette from dispenser module x and check con tents of banknotes Is the correct banknote type in the cassette Are the front bank notes deformed on one side Is the pressure against the front banknotes even on the right and on the left side With the cassette removed check the dispensing area in the dis penser module for stuck banknote scraps see section Checking the cash paths Check the transport path from cassette x to the clamp for jammed banknotes scraps see section Checking the cash paths Check the connectors at the CMD controller Determine the reference value see section Determining the ref erence value BEETLE iSCAN Scan amp Bag Hardware User Manual Banknotes cannot be dispensed Check the contents of cash out cassette x for position and or incorrect pressure on notes in quality of banknotes see sections Preparing banknote bun new cassette dles and Inserting the banknote bundles x 1 6 Check the dispensing area for stuck banknotes see section Checking the cash paths Place the cassette in position again and check the function with a test dispense see section Function test HE Too EE bad banknotes Check the contents of cassette x x 1 8 f Barnes aing Replace the defective cassette with a new initialized cassette X 1 Banknote measuring stati
39. ert the paper into the printer as shown in the illustration Z Mind the direction in which the paper unrolls I v Pos A For rolls with a diameter of 180 mm 5 Pos A x For correct paper feed or paper transport the front edge of the paper has to be cut with scissors to get a right angled sharp edge Take the front edge of the paper over the upper axle and feed it VEN Re into the paper support see arrow Keep pushing the paper into the paper support until it is drawn ft in automatically cut off and the produced receipt is output via P 4 the presenter x If the paper is loaded correctly the following text will be printed ES gt o W on the first receipt W 4 If you can read this print ro G A E Autoloading is successful aN Va Remove the cut off receipt 11 BEETLE iSCAN Scan amp Bag Hardware User Manual Cash Media Dispenser Vertical Cash Out Unlock the door arrow and open it BEETLE iSCAN Scan amp Bag Hardware User Manual Enter the pin und turn the wheel to the right 1 Turn the other wheel 2 until you can open the door of the safe Grab the green lever white arrow and pull out the Cash Media Dispenser completely 13 BEETLE iSCAN Scan amp Bag Hardware User Manual Modules and function elements DAR OW M OO 1 Stacker and output transport facility SAT Function key Not in BEETLE iISCAN Scan amp Bag CMD controller Cash out cassette 1 Reject retract cassette
40. es remove the battery and insert the Reset Box into the BAT inlet of the lock The Reset Box must be connected to a 9V ALKALINE bat tery The lock is in the Factory mode again Pre Setup Mode Safety notice Do not assign codes to the users of no use for the time being Remove the codes Function 3 and user number 91 Hardware User Manual BEETLE iSCAN Scan amp Bag Block Diagram Spea x2 x3 Gontrol Pane X7 x ker Proxy N 14 21h ep ad Set Of Lights TouchScreen has Proxy EJ 214 MEI Coupon Waiter Lock Ii MEI Note OUT T Handscanner Shutter CMD V4 Separator Eg Safety Switch N BEETLE M USB Top 24v v24 5V 12V 12v i lanla Mains Power Supply CT USB Keyboard Control 29 L Extension Q 22 Separator T DS HardTag Power Distributor zv ted Antenna 6 Inlet Connector 2 PIN 230 V 27 CEE i USV optional Pluc 92 BEETLE iSCAN Scan amp Bag Hardware User Manual Environmental Requirements Operating temperature Ambient temperature B C 35 C Humidity 5 r h 1 g m 85 r h 25 g m Temperature change 0 5 K min max 7 5K 30 min Barometric pressure 70 kPa 106 kPa 70kPa corresponds to an installation at approximately 3000 meters above sea level Installa tion environments with long periods of sunshine should be avoided Storage conditions Ambient temperature 5 C 40 C
41. es must always point to the side from which the notes are dispensed The bulging side always has to point to the pressure carriage cassette handle 23 BEETLE iSCAN Scan amp Bag 24 Hardware User Manual Type A Turn the bundle so that the deformed corner of the banknote is pointing not to the pres sure carriage Type B Bundles whose S shape is pronounced and exceeds 5 mm should not be used If no other banknote bundles are available the entire bundle needs to be formed to a U shape as to be fit for use Insert these bun dles so that the deformed corners are point ing at the bottom to the pressure carriage Type C If the bundle has a wavy shape as a result from having been tied turn it so that the deformed corners are pointing to the pres sure Carriage BEETLE iSCAN Scan amp Bag Hardware User Manual Inserting the cassette i The procedure for inserting cash out cassettes and reject retract cassettes is the sa me Closing the cassette If the cassette has a lock close the cassette lid 1 and turn the key 2 to the left as far as possible Pull the key from the cassette lock 25 BEETLE iSCAN Scan amp Bag Hardware User Manual Inserting the cassette Normally the tamper indicator 1 is green If the indicator is blue the cassette has been tampered with or has been forced open tamper indicator To switch the tamper indicator to green proceed as follows Unlock the casset
42. he operating manual for the system e Pull the lower level out or when removing coin chute 2 also pull the upper level out Move the wing 1 of the bent lever closure 90 in the direction of the arrow Turn the wing 1 counterclockwise and lower the bent lever closure in the direction of the arrow Lower the coin chute in the direction of the arrow and detach it When installing the coin chute make sure that the tabs 1 and 2 on the left of it and the bolt 3 in the middle of it are inserted correctly in their open ings 49 BEETLE iISCAN Scan amp Bag Hardware User Manual Coin change machine CM IO S 6H R i Coin chute 1 on the lower level and coin chute 2 on the upper level are detached in the same way e Turn the device off see the operating manual for the system e Pull the lower level out or when removing coin chute 2 also pull the upper level out Move the wing 1 of the bent lever closure 90 in the direction of the arrow Turn the wing 1 counterclockwise and lower the bent lever closure in the direction of the arrow 2 Lower the coin chute in the direction of the arrow 3 and detach tt When installing the coin chute make sure that the tabs 1 and 2 on the right side of it are inserted correctly in their openings see arrow 50 BEETLE iSCAN Scan amp Bag Hardware User Manual Overview of possible hopper configurations AN The configuration of the individual coi
43. ins that are recognized as genuine currency are routed to the coinbox via the coin output position coinbox 54 BEETLE iSCAN Scan amp Bag Dispensing small change Coin change machine CM IO S 6H L Lower and upper levels Coin hopper hopper 2 or hopper 4 2 Coin hopper hopper 1 or hopper 6 3 coin hopper hopper 3 or hopper 5 Bypass chute 5 Coin chute chute 1 or chute 2 Hardware User Manual 55 BEETLE iSCAN Scan amp Bag Hardware User Manual Coin change machine CM IO S 6H R Lower level 1 coin hopper hopper 2 Bypass chute 2 coin hopper hopper 1 5 coin chute chute 1 e _ Coin hopper hopper 3 LI 56 BEETLE iSCAN Scan amp Bag Hardware User Manual Upper level Coin hopper hopper 4 Bypass chute fe hopper hopper 6 5 Coin chute chute 2 The coins in the hoppers are collected by the separator disk transported upwards and ejected via a spring mechanism Lower level The coins from hoppers 1 and 2 roll straight into coin chute 1 The coins from hopper 3 roll through the bypass chute through hopper 1 into coin chute 1 Upper level The coins from hoppers 4 and 6 roll straight into coin chute 2 The coins from hopper 5 roll through the bypass chute through hopper 4 into coin chute 2 The coins fall from coin chute 2 into coin chute 1 57 BEETLE SCAN Scan amp Bag Hardware User Manual Error messages Error messages are output to the LCD on
44. n is the same as entering the code for opening After valid code entering the time delay starts to run which can be recognized by the LED signal each 2 sec After delay period ex pired the time period for opening starts which can be recognized by alternate acoustic and LED signal each second During the time period for opening the valid code must be entered to reach the opening At the operation with two codes must two valid codes be entered during the time period for opening to succeed When no valid code is entered during time period for opening the lock is time secured again When the delay should be interrupted press the key 0 The user ID 9 WTU can open immediately At the operation with two codes the ID 9 is entered as the second code When the capacity of the battery is too low a series of acoustic signals is heard at opening According to the capacity of the bat tery it may be also only 3 4 or 5 acoustic signals Change the battery Use 9V ALKALINE batteries only The codes are stored in the lock even without power supply The battery compartment is installed down in the keypad When connected to the alarm equipment through the interlock device SP then the power supply is secured from this place Change the code immediately and carefully store on a secure place do not use your personal data telephone number date of birth etc as a code BEETLE iSCAN Scan amp Bag LED and acoustic signals 1
45. n hoppers is determined by the application and can only be executed by the Service department The individual hoppers and the admissible coin types coin sizes that can be processed by the hoppers are set to the standard configuration in the factory If customers require a specific coin hopper configuration that differs from the factory setting both the hardware coin hoppers and the software must be configured by the service department The table below shows which separator disk and which dispenser blade must be installed or config ured in the coin hopper in order to output a special coin type 51 BEETLE SCAN Scan amp Bag Hardware User Manual Europe euro Standard configuration factory setting for European currency 0 02 12 compartments white 0 01 12 compartments white Additional configuration options To be dispensed from hopper no X with the configuration Separator disk Blade Currency coin Coin dimen 8 cmp red 7 cmp black 12 cmp white 18 30 mm 1 2 20 32 mm 1 2 12 20 mm 1 2 3 2 mm 3 2 mm 3 2 mm 1 cent 16 25 mm 1 2 4 6 1 3 mm 1 67 mm 2 Cent 18 75 mm 1 2 4 6 1 3 mm 1 67 mm 5 cent 21 25 mm 1 2 4 6 Standard 1 67 mm long 10 cent 19 75 mm 1 2 4 6 Standard 1 93 mm long 20 cent 22 25 mm 1 2 3 Standard 2 14 mm 4 5 6 long 50 cent 24 25 mm VIZ FSH Standard 2 38 mm 4 5 6 long 1 euro 23 25 mm La 2h 34 Standard 2 33 mm 4 5 6 long 25 75 mm 172534 Stand
46. notes into the cassette first Then insert the bundles with the new banknotes after you separated them at the cut edges see the section Preparing banknote bundles Insert banknote bundles which were deformed by packaging bands with paper plastic or elas tic bands as follows Split the banknote bundle and turn the first half of the bundle so that the bent side is pointing towards the pressure carriage Insert the two bundle halves into the cassette as shown in this picture Please do not use any extremely deformed banknotes Always insert banknote bundles which are bent horizontally into the cash out cassette in such a way that the side of the bundle bulging out is pointing towards the pressure carriage Take the banknote bundles from the packaging fan the banknotes and put them into the cas sette as shown in the picture BEETLE iSCAN Scan amp Bag Hardware User Manual Press the green latching button on the pressure carriage and push the carriage against the banknotes far enough to pre vent them from falling over The inserted banknotes do not need to be pressed to gether Close the cash out cassette and re insert it see section Inserting the cassette Possible deformation of banknotes Type A Type B Type C Deformation near the hologram S shape Wavy shape The following illustrations show in which order the deformed banknotes have to be inserted Note that the deformed corners of the banknot
47. nsport Opening the cassette i The procedure for opening cash out cassettes and reject retract cassettes is the same Remove any seal 1 on a cassette with a sealable lock Insert the cassette key into the cassette lock turn the key to the right as far as possible 2 and lift the cassette lid in the direction of the arrow 3 18 BEETLE iSCAN Scan amp Bag Hardware User Manual Emptying the reject retract cassette The reject retract Cassette is divided into a reject and a retract compartment Banknotes which are not removed by the customer after the cash dispensing procedure are returned to the retract compartment Cash which has been incorrectly dispensed or which was dispensed for test purposes Is stored in the reject compartment Remove and open the cassette see section Opening the cassette Remove the banknotes from the cas sette s reject compartment To empty the retract compartment push the green lever in the direction indicated as far as possible and hold it down You can remove the cash from the retract compartment with your other hand 2 19 BEETLE iSCAN Scan amp Bag Hardware User Manual Filling the cash out cassette Filling the cash out cassettes includes the following steps Preparing the cash out cassette Preparing the banknote bundles Inserting banknote bundles In general all banknotes complying with the requirements of the national banks are suit able for use in
48. nsported into the position where they can be removed the shutter is partly closed depending on the thickness of the banknote bundle The thickness of the bun dle is detected by the thickness measuring unit in the CMD V4 The value that is identified is used to control the drive motor for a limited time When the cash has been removed the shutter is first opened completely via the firmware and the drive belts in the transport gripper are briefly moved backward Then the shutter is closed completely and locked unless this is prevented by external influences Error code 28 If the shutter does not close within approx 1 second the firmware turns the motor off generates an error code error code 28 displayed on the CMD V4 controller and reports the error to the application Error code 29 protection against tampering Error code 29 is displayed if photosensor LS 27 is covered when the shutter is closed The firmware tries to close the shutter anyway The motor is turned off if that does not succeed within approx 1 second 61 BEETLE SCAN Scan amp Bag Hardware User Manual Bank Note Input Introduction The Note Input used in the BEETLE iSCAN has an acceptance rate which is higher than 90 inclu sive first time rejection and second time acceptance This acceptance rate includes notes with the following features Moist Dirty Torned up Extremely rumpled Worn out Folded The identification time is smaller than 2 seconds u
49. ntil the credit signal appears Technical Data Accepted notes 5 10 20 100 500 Avarage capacity 500 bank notes 62 BEETLE iSCAN Scan amp Bag Hardware User Manual Single Banknote Authenticator The single banknote authenticator is a component that is used to implement a payment function with banknotes Payments are made by inserting individual banknotes in the banknote input slot The banknotes are tested in the validation unit and if they test positive are sorted and conveyed by the transport unit to a cash cassette where they are stored Alternatively if the test is not positive they are returned to the output tray 63 BEETLE iSCAN Scan amp Bag Hardware User Manual Controls gt fonemene R Re ee fom 64 BEETLE iSCAN Scan amp Bag Hardware User Manual Status LEDs Status LEDs 1 and 2 are located below the banknote input slot ar gt Both LEDs on The single banknote authenticator is ready to accept a banknote Both LEDs off The single banknote authenticator is not ready to accept a banknote This may be due to the following reasons The single banknote authenticator is processing a banknote A problem has occurred 65 BEETLE iSCAN Scan amp Bag Hardware User Manual Inserting a banknote Always insert one banknote at a time The banknote is inserted short edge first with the banknote in any position Torn repaired crumpled folded stapled or clipped
50. office equipment for use within an office environment i To disconnect the device from the mains disconnect the CEE Nema Type connection or disconnect it by fuse of the building installation i If UPS is installed you must switch off this too to separate BEETLE iSCAN Scan amp Bag from power completely e Appliances may only be repaired by authorized technicians e Unauthorized opening of the housing or inexpert repairs can result not only in considerable per sonal danger but will also invalidate your warranty and liability protection e Always consult the enclosed documentation before doing any work with this appliance e If this device is brought from a cold environment into a heated place of business condensation may occur Before operation the device must be completely dry Therefore an acclimatization pe riod of at least two hours must be adhered to e Exchange damaged cables immediately e Always lay the supply leads and cables in such a way that they cannot be stepped on or tripped over e In order to completely disconnect the device from the power source turn the device off and use the separator in the fuse box building installation e Make sure that no objects such as paper clips can reach the interior of the device since electrical shocks or short circuits could result e To avoid overheating of the power supply unit ensure that the BEETLE iSCAN receives adequate ventilation e During an electrical
51. on Connect the interface data reading cable PN 42160 to the corresponding port Start the program LG View 3x and click with the mouse on the safe symbol start acquisition Insert the interface connector from the side into the keypad 3750K For the keypad 3750 on the lock an adapter cable is used Enter the manager code and keep pressed the last number until the double signal LED is on is repeated and shortly press the 7 The data are transferred from the lock to the PC and shown in a list which can be printed The audit trail can be stored in the PC memory with SAFE and en tering the file name with a LOG extension The program calling is made with Load program loading The item Infos offers you a message about the lock status The user status is shown in a ten unit group of characters with manager first and second to tenth place the user numbers 1 9 Meaning initialized code is active E enrolled code changed manager only D disabled code disabled removed the code can be entered again B blocked code cannot be enabled BEETLE iSCAN Scan amp Bag Hardware User Manual G Time delay for opening Manager can set the time delay for opening with the function 9 function 9 The values of the time delay 1 99 minutes and of the time period for opening 1 19 minutes are entered in a four unit block where the first two places are minutes of the delay and the further
52. on Check whether there is a banknote jam in the upper dispensing DDU not ready unit Are the cables connected If the error message does not disappear contact customer service x Dispensing sensor PSDx dirty or eres sensor faulty x 1 at empty sensor PSEx r d x 1 Bui S 1 g g g Checking the note paths Before checking the banknote paths you should perform the following steps Activate the product specific software e Open the safe Holding the green release lever pull out the CMD V4 as far as possible i If the release lever jams you must check the current position of the clamp If possible push the clamp carefully back to its home position Perform a reset using the function button Now check whether you can remove the CMD V4 29 BEETLE iSCAN Scan amp Bag Hardware User Manual Checking the dispensing areas i In the dispenser modules the vertical transport at the rear and the dispensing area inside the device must be checked The dispensing areas can only be checked when the cassettes have been removed from the dispenser modules see section Removing the cassette Check the dispensing area of each dispensing module for banknotes and if necessary remove the notes See arrow a ES AX E LU 7 LNA e S A r D P ING NG IME YO Re insert all cassettes which were removed see section Inserting the cassette Log on the cassettes using the produ
53. ouble signal and enter the ID Nr e g 2 single signal The user ID No 2 is removed The Manager can anytime make the inquiry which user is enabled disabled or removed Enter the manager code and keep pressed the last number until the double signal LED is on is repeated keep pressed the 7 until the double signal is once more repeated Press the user ID No 1 9 and watch the signal 1 acoustic signal enabled 2 acoustic signals disabled 3 acoustic signals removed Long acoustic signal disabled it can not be enabled Finish press 0 At the operation with two codes 4 eyes principle the valid user code must be entered before the manager code to be able to do the programming Six unit code manager 123456 85 BEETLE ISC AN Scan amp Bag F Reading the audit trail PC setup Start program Reading the audit trail function 7 86 Hardware User Manual In the lock memory records of the last 50 openings are stored with the user ID which can be read on a PC or laptop In a PC with Windows 95 or later the program LG View 3x Setu pExe is loaded and the COM port is set with the parameters 1200 bauds non parity 8 data bits 1 stop bit When the laptop has no COM port then this connection must be made with the PCMCIA card RS 232 or a corresponding USB adapter Start the program LG View 3x and set the corresponding port in the item KONFIGURA TION configurati
54. per Scanning Technique The scanner was designed to provide the ultimate in ergonomic enhancements for Point Of Sale POS scanning To take advantage of these advancements Practice the techniques below to improve scanning efficiency e Move the product across the horizontal window e Since the scanner reads labels on all four sides plus the top and bottom don t favor either the hori zontal or vertical scan windows e Keep items in their natural orientation e Remember to slide or push items rather than picking them up By avoiding any gripping twisting and rotation of your hands and wrists you can prevent repetitive motion injuries This technique also relieves you from lifting possibly thousands of pounds per day e Develop a smooth fluid motion during scanning sharing work equally between hands e Use the entire hand for grasping and lifting items BEETLE iSCAN Scan amp Bag Hardware User Manual e Develop efficient scanning motions not necessarily faster hand movements e Learn typical locations for bar codes on packages avoid flipping or rotating the items during scan ning Proper Weighing Technique e The L shaped All Weighs platter allows you to place items anywhere on its surface including leaning against its vertical section to be weighed accurately The raised Produce Rail also pro vides a convenient way to ensure items do not rest on the counter or other non weighing surfaces WY R __ Produce
55. spensing transactions Coin change machine CM IO S6H L has the coin slot on the left of the module whereas coin change machine CM IO S 6H R has it on the left Payments are made by inserting single coins in succession in the coin slot The coins that are inserted are authenticated in the coin checker and if found to be valid currency stored in a coinbox or if not returned for output Small change is dispensed from six coin hoppers Error messages are output to the LCD on the ser vice and diagnostics panel 35 BEETLE iSCAN Scan amp Bag Hardware User Manual Controls Coin change machine CM IO S 6H L Front view L CEE E oF pre Cere et gt KJ LE ETNE EST a LETE LE tee mem mrt H p oreore 36 BEETLE iSCAN Scan amp Bag Hardware User Manual Lower level pulled out Se ee whe 2 Coin hopper cover 3 hopper 3 Coin hopper cover 1 hopper 1 e Lock for the lower level 3 Coin hopper cover 2 hopper 2 37 BEETLE iSCAN Scan amp Bag Hardware User Manual Upper level pulled out 1 Coin hopper cover 5 hopper 5 2 fcon chute 2 2 Coin hopper cover 4 hopper 4 loa hopper cover 6 hopper 6 38 BEETLE iSCAN Scan amp Bag Hardware User Manual Coin change machine CM IO S 6H R Front view Vemma ee vem 1 T oreroraa fonem 39 BEETLE iSCAN Scan amp Bag Hardware User Manual Lower level pulled out ea no 5 2 Rm PG i
56. suant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications not authorized by the manufacturer may void users authority to operate this device This class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe A est conforme a la norme NMB 003 du Canada 94 BEETLE iSCAN Scan amp Bag Hardware User Manual Recycling the BEETLE iSCAN Scan amp Bag The BEETLE iSCAN Scan amp Bag was designed ac cording to the Wincor Nixdorf standard Environ mentally Conscious Product Design and Develop ment The BEETLE iSCAN Scan amp Bag is manufactured without the use of CFCs and CCHs and is manu factured to a great extent out of materials and components which are recyclable For recycling purposes do not attach any additional adhesive labels to the device Wincor Nixdorf disposes of old devices in an envi ronmentally responsible manner at a recycling cen ter that is ISO 9001 and ISO 14001 certified as
57. te using the key and turn the locking unlocking lever to the left Open the lid see section Opening the cassette Close the cassette lid and turn the locking unlocking lever to the left as far as possible Lock the cassette using the key see section Closing the cassette Push the cassette back into the CMD V4 in one unin terrupted motion until it audibly latches into place Wait for the single signal tone confirming the correct pressure build up in the cassette fa triple signal tone sounds instead of a single tone remove the cassette and check the con tents of the cash out cassette see the instructions in the section Filling the cash out cas sette Then try again to insert the cassette The acoustic warning triple signal tone is accompanied by a message on the status display of the controller ZAC Example 4 i I Cash out cassette 1 Cassette initialization The initialization of the cassettes is necessary in case of new types of banknotes or cassettes With the initialization the system will be informed about the cassette number the currency and the denomi nation of the banknotes If necessary you can enter more parameters Please observe the product specific and bank requirements concerning change of standard or individ ual changing of cassettes Please obtain this information from the bank s administration 26 BEETLE iSCAN Scan amp Bag Hardware User Manual Status messages CMD controller
58. the factory mode It is opened when pressing the key 1 and it sends at the same time the alarm Thus the simple and flexible storing is reached and the simple operation during manufacturing is secured On PC laptop the operating system Windows must be in stalled and the program LG 39E SETUP requiring 4MB must be loaded Insert the interface cable into the corre sponding COM port of your PC When the laptop has no COM port this connection must be made with the PCMCIA card RS 232 or a corresponding USB adapter Configure the port 1200 bauds non parity 8 data bits 1 stop bit and start the program LG39E SETUP The programming is made in clear text english and is very simple When operating with a parallel code each code is open ing the code length must be of seven units When operating with two codes The code length is six units Activate user The preset codes can be overwritten The active users to whom no code was assigned can be enabled later Not activated users cannot be enabled later Insert the interface connector into the keypad or into the adapter of the lock which is ready for operation and click the mouse on the item TRANSMIT Send and then press the key 0 on the lock keypad With this program it is possible to make the programming of several locks It is possible to save it for later consumer pro gramming File Save as After SETUP programming the lock is still in Factory mod
59. two places are minutes of the time period of opening min 1 minute If the setting should be made with 10 minutes of time delay and 5 minutes of time period for opening then the four unit block is as fol lows 1005 Enter the manager code and keep pressed the last number until the double signal LED is on is repeated Press 9 and enter the time block 1005 double acoustic signal and confirm with a re peated entering of 1005 double acoustic signal The changing of the time values can be made only in the time period for opening If the time delay override is set then the user ID Nr 9 can open im Time delay override mediately e g WTU When operating with two codes then the code of the ID No 9 is entered as second one This override code of the ID No 9 can be enabled only in the time period for opening or before the time delay is set Lock programming The program selection of the lock two codes alarm delay override is made by programming on PC 39E Setup or manually on the key pad At the operation with two codes 4 eyes principle the valid user code must be entered before the manager code to be able to make the programming Six unit code manager 123456 87 BEETLE ISC AN Scan amp Bag Programming on PC FACTORY Mode Pre Setup mode Programming on PC PC setup Code length Program transfer Exit the Factory Mode 88 Hardware User Manual The lock may be installed in
60. x short signal 2 x Short signal 3 x short signal 6 x short signal Hardware User Manual enter confirmation valid code entered wrong code not accepted remote interlock the alarm equipment was not released LED signal each 10 sec 1 flashing Interlocking time after a wrong entry LED signal each 2 sec Time Delay for opening is running Alternate LED and acoustic signals Time period for opening is running A series of acoustic signals ca 3 sec Low battery capacity Still available ca 10 openings Dependent of the battery capacity there may be also less acoustic signals Therefore the battery change should be made also in case of double or triple signals without ready time for opening Use ALKALINE batteries only 83 BEETLE SCAN Scan amp Bag Programming Manager Manager function Overview Manager code A Manager code change at the opened door function 0 B Enable user function 1 84 Hardware User Manual Manager code change ID Nr 0 function 0 Enable user ID Nr 1 9 function 1 Disable user function 2 Remove user function 3 User status inquiry function 7 keep pressed Reading the audit trail function 7 Setting the time delay for opening function 9 It is possible to open the lock with the factory code 1234567 Change the code immediately Enter the manager code or the old code and keep pressed the last number until the doubl