1. Emissions Inventory Guidelines individual operation using the guidance in this supplement and the following information e the amount and type of material processed e speciation of any VOC or particulate emissions e temperature vapor pressure molecular weight and any other data necessary to determine emissions Report the resulting emission rates at the appropriate facility emissions point paths as the annual emissions rates Do not use average or typical operations data to determine actual annual emissions To obtain ozone season emission rates for each facility emissions point path first determine emissions in pounds that the facility generated and emitted during the months of June July and August Next divide the resulting emissions rates by the number of days that the facility operated during the months of June July and August Report the resulting rates as the ozone season pound per day emissions rates for that facility emissions point path Note that the number of days that a facility can operate during the ozone season cannot exceed 92 For more information consult Reported Emissions Ozone Season Emissions in Chapter 4 VOC and Particulate Speciation A 62 Speciation should follow the 2010 Emissions Inventory Guidelines In general Emissions from bulk liquids and liquefied gaseous materials loading and unloading will be VOCs with a composition corresponding to that of the material loaded or un
2. not known the inlet gas analysis cannot be used to speciate the VOC emissions because complex oxidation reactions occur in the combustion chamber that alter the emissions composition significantly Therefore the emission factors in AP 42 should be used to speciate the VOC emissions In AP 42 formaldehyde is one of the Trace Organic Compounds that has an emission factor 0 0528 Ib MMBtu with a grade C or better The total VOC emission factor in AP 42 is 0 118 Ib MMBtu To obtain formaldehyde s speciation ratio divide the formaldehyde emission factor by the total VOC emission factor 0 0528 0 118 1 0 44746 MMBtu MMBtu The engine s total VOC emissions should be multiplied by this ratio to determine the formaldehyde emissions 11 2 tons VOC x 0 44746 5 0115 tons formaldehyde If this calculation is performed for each trace organic compound with a factor graded C or better there are 27 speciated emission rates that should be determined However only eight of those exceed the 0 1 ton threshold The speciated emissions for these eight compounds should be reported in the EI and the remaining balance of the total VOC emissions should be reported under VOC unclassified as shown in Table A 2 TCEQ publication RG 360A 10 m January 2011 Technical Supplement 1 Combustion Sources Table A 2 Reporting Internal Combustion VOC Emissions Contaminant Annual Determination Code Contaminant Emissions Methodology 50001 VOC
3. unclassified 0 2240 ton V 51620 acetaldehyde 0 7935 ton 51640 acrolein 0 4879 ton 51680 formaldehyde 5 0115 tons 51530 methanol 0 2373 ton 56150 methylcyclohexane 0 1167 ton 56600 n hexane 0 1054 ton 56750 n pentane 0 2468 ton 56775 propane 3 9769 ton S S S S S S S S Ozone Season Emissions Ozone season emissions should reflect an average daily emission rate Do not report maximum daily emissions based on a design capacity and the assumption that the facility operated 24 hours each day For sources that run regularly throughout the ozone season divide the total emissions from June July and August by the number of days the facility is operated For sources that run intermittently during the ozone season e g emergency generators that operate a few hours every couple of weeks use a straight conversion of the annual tons per year to pounds per day External Combustion Sources Burning Natural Gas Expected Contaminants Reported boiler emissions should include all of the following TSP contaminant code 10000 e PMyjo contaminant code 20000 e PM gt 5 contaminant code 39999 e VOCs contaminant codes 50001 through 59998 NO contaminant code 70400 SO contaminant code 70510 TCEQ publication RG 360A 10 m January 2011 A 11 Emissions Inventory Guidelines CO contaminant code 90300 Emissions Determination Methodologies The appropriate emission determination methodologies for boilers are
4. Therefore when determining emissions from nitrogen blanketed atmospheric storage tanks whether the tank is of fixed roof or internal floating roof design no modifications to the AP 42 equations or software programs using these equations are required The gas blanket will not affect emissions if the tank is operated near atmospheric pressure Heated Tanks If a tank is heated the vapor space can be assumed to be at a constant temperature and no breathing losses will occur The tank must be heated to a uniform temperature and well insulated thus isolating it from heat gains and losses as well as variations in ambient temperature Changes in atmospheric pressure are assumed to have only negligible contributions to breathing losses and are not considered When using the TANKS program answer yes to the menu selection Is Tank Heated on the Physical Characteristics screen to determine emissions from vertical and horizontal fixed roof tanks Enter the temperature data directly on the Tank Contents screen Temperature data input fields exist for Average Minimum and Maximum Liquid Surface Temperature and for Bulk Liquid Temperature degrees Fahrenheit The temperature that the tank is heated to should be entered in all four data fields The ranges for vapor space and liquid surface should be determined using the AP 42 equations and input to obtain an estimate of tank emissions TCEQ publication RG 360A 10 m January 2011 Tec
5. in order of preference e D continuous monitoring system F predictive monitoring system e M measured stack test data e Q portable analyzer test data e V vendor supplied emission factors e A AP 42 factors e S scientifically calculated E estimated New for this year Portable analyzers have their own determination methodology and should be designated as Q Testing conducted with a portable analyzer does not qualify as stack testing therefore the emissions determination methodology should not be reported as measured M If the stack test results from an identical unit are used to determine the emissions the emissions determination methodology should be reported as estimated E If none of these methodologies accurately represent a source s emissions contact the EAS for further assistance SO Emissions If any sulfur is present in a source s inlet gas the source will emit sulfur dioxide as a product of combustion CEMS PEMS and stack test data is the preferred order when identifying the determination methodology for SO emissions In lieu of using a vendor or AP 42 SO2 emission factor the SO emissions should be determined using a material balance based upon the combusted fuel s sulfur content Particulate Emissions A 12 Combustion sources emit particulate matter Furthermore all of the particulate matter emitted from boilers as a result of combustion has an aerodynami
6. operations consult the current version of AP 42 Chapter 5 2 Quantifying Storage Tank Emissions Determining Emissions from Breathing and Working Losses Emissions from storage tanks occur because of evaporative losses of the liquid during storage breathing losses and as a result of changes in liquid level working losses Determining breathing and working loss emissions from liquid storage tanks should be consistent with the current edition of AP 42 Chapter 7 Using the current version of the TANKS program the EPA s free software that calculates fixed roof and floating roof storage tank emissions will help to ensure that emissions determinations are consistent with the current edition of AP 42 The current version is available at lt www epa gov ttn chief software tanks index html gt TCEQ publication RG 360A 10 m January 2011 A 67 Emissions Inventory Guidelines A 68 Annual and Ozone Season Emissions Annual and ozone season breathing and working loss emissions can be determined by using the current TANKS program or by following the guidance outlined in AP 42 Chapter 7 The EAS requests the summary or detail report types from the TANKS program to be included with the sample calculations These reports include sufficient information to verify the emissions Annual emissions should be determined by generating a TANKS report and choosing the monthly time basis and selecting all 12 months of the year Thi
7. require that the emissions determinations be recalculated using a more appropriate method Note that the TANKS program does not determine flash loss emissions and cannot be used to determine losses from unstable or boiling stocks or from mixtures of hydrocarbons or petrochemicals where the vapor pressure is not known or cannot be readily predicted Black Oil Systems Black oil is defined as heavy low volatility oil approximated by a GOR less than 1 750 cubic feet per barrel and an API gravity less than 40 The appropriate methodologies for determining flash emissions for black oil systems are in general order of preference direct measurement of emissions code as M e process simulator models code as S e the E amp P TANK program code as O e Vasquez Beggs or Rollins McCain and Creeger correlations or software that uses these correlation equations such as GRI HAPCalc code as O e the gas oil ratio GOR method code as B Please note that crude oil with an API gravity greater than 40 should be treated as gas condensate when determining flash emissions Gas Condensate Systems Gas condensate is defined as a liquid hydrocarbon with an API gravity greater than 40 at 60 F and a specific gravity less than 0 8252 The TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks appropriate methodologies for determining flash e
8. AP 42 equations Tanks Storing Inorganic Liquids Currently methods developed exclusively for determining inorganic compound emissions from storage tanks do not exist However it is possible to use the TANKS program to determine storage tank emissions from inorganic liquids if the inorganic liquid has a measurable vapor pressure and if data are available for one of the vapor pressure options in the program s chemical database Although the equations used in the TANKS program were developed to estimate evaporative losses from storage of organic liquids they currently present the best available method for determining inorganic emissions from storage tanks Tanks with a Liquid Heel Care must be taken when classifying a tank as drain dry If the tank drains to a sump that retains a liquid heel the API publishes saturation factors to use in the landing loss equations in order to determine the resulting emissions which cannot be assumed to be negligible TCEQ publication RG 360A 10 m January 2011 A 79 Emissions Inventory Guidelines A 80 Operations where potential emissions are generated and released include degassing operations tank cleaning steam cleaning and the use of vacuum trucks Oil Field Wellhead Tank Batteries A recent Houston Advanced Research Center study HARC 51C Evaluation of VOC Emissions from Flash and Condensate Tanks has shown significant emissions from wellhead crude and condensate storage tank
9. Marketing Terminal Factors O Other explain LDAR PROGRAM O None OF 28M O28RCT O28VHP QO 28MID O 28LAER OAVO O28CNTA O28CNTQ OHRVOC O Other TCEQ 20417 12 14 08 Page 1 of 1 TCEQ publication RG 360A 10 m January 2011 A 45 Emissions Inventory Guidelines Instructions for Completing the Fugitive Data Form Component Counts A 46 Enter the number of each component type valves flanges etc in each service gas vapor light liquid etc Note that water light liquid service applies only to the oil and gas industry Be certain to fill in all columns Unmonitored Number of Components For each component type enter the number of unmonitored components in the fugitive area If an LDAR program is in place include components exempt from monitoring in this column Monitored Number of Components For each component type enter the number of instrument monitored components in the fugitive area Leak Definition For each monitored component type enter the leak definition level measured in parts per million Number of Leakers For each monitored component type enter the number of components that leaked at or above the leak definition threshold Count each component once for each period that it leaked For example if a valve monitored quarterly was found to be leaking each quarter in a year it should be counted as four leakers Number Pegged For each monitored component type enter the number of compone
10. Preferred and Alternative Methods for Estimating Fugitive Emissions from Equipment Leaks Vol 2 Emissions Inventory Improvement Program Document Series chapter 4 Available online at lt www epa gov ttn chief eiip techreport volume02 index html gt Accessed October 28 2010 A 44 TCEQ publication RG 360A 10 m January 2011 Fugitive Data Form TCEQ Emissions Inventory Year COMPONENT COUNTS Unmonitored Monitored Number of Number of Leak definition Number of Number Monitoring components components ppm leakers pegged frequency Gas Vapor Heavy liquid H O Light oil Gas Vapor Light liquid H2O Light oil Gas Vapor Light liquid Heavy liquid H20O Light oil Gas Vapor Light liquid Heavy liquid H O Light oil Gas Vapor Light liquid Heavy liquid H2O Light oil Gas Vapor Light liquid Heavy liquid H2O Light oil Gas Vapor Light liquid Heavy liquid H O Light oil Gas Vapor Light liquid Heavy liquid H2O Light oil VOC PERCENTAGES Gas vapor stream Light liquid stream Connectors Compressor Seals MONITORING EQUIPMENT DATA Pegged Component Screening Value Calibration Range min EMISSIONS DETERMINATION METHODOLOGY OR LDAR PROGRAM USED O Oil and Gas Factors O SOCMI Average Factors O SOCMI without Ethylene Factors O Refinery Factors O SOCMI with Ethylene Factors O Correlation Equations O Petroleum
11. The component specific emission factors for pressurized railcar loading operations threaded connections and quick connect couplers are listed in Table A 5 and should be applied when a pressurized railcar is connected to the loading system using a loading arm The loading arm may consist of a combination of threaded and quick connect components and each component should be included in the EI Special Considerations when Quantifying Emissions A 38 When determining fugitive emissions the hours of operation and equipment design specifications need to be considered Hours of Operation Fugitive emission factors for piping components are independent of process unit throughput Because emissions occur whenever material is in the line regardless of process activity or downtime all streams should be in service for 8 760 hours annually Any exception to this service time would require that the lines be purged during process downtime TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives Table A 5 Appropriate Substitute Factors for Nontraditional Components To determine this nontraditional component s emissions use this factor Heat exchanger head unmonitored Open ended line monitored Flange correlation equation Pressurized railcar loading arm threaded connection 0 0214 Ib hr component quick connect coupler 0 0055 Ib hr component Equipment Design Specifications Certain facilit
12. This guidance reflects the current understanding of how piping components work how they generate emissions how they are monitored or tested and what data are available for emissions determination This supplement may change over time as a result of findings of scientific studies and as new information becomes available The EAS greatly appreciates any data information or feedback that may improve this supplement The calculation methods represented are intended as an emissions calculation aid alternate calculation methods may be equally acceptable if they are based upon and adequately demonstrate sound engineering assumptions or data For additional guidance regarding the acceptability of a given emissions determination method contact the EAS at 512 239 1773 Introduction This technical supplement offers guidance for identifying determining and correctly reporting fugitive emissions from piping components and associated equipment at industrial facilities It does not address emissions from cooling towers oil water separators material stockpiles loading operations or other sources not related to piping components Please note that structural representation of piping components as a fugitive area in the EI is specifically addressed under Issues of Special Concern later in this supplement For general guidance on this topic consult Chapter 3 Emissions Inventory Structure Definitions In this document traditiona
13. a duct burner two data sets should be used to determine the emissions one representing emissions with the duct burner on and the other with the duct burner off If two separate data sets do not exist or if another method is used to determine emissions contact the EAS for guidance Particulate VOC and SO Emissions For guidance on determining and speciating these emissions see Internal Combustion Engines earlier in this supplement Air Curtain Incinerators Structure Air curtain incinerators forcefully project a curtain of air across a pit where open burning occurs The air curtain is intended to increase combustion efficiency and reduce smoke and PM emissions Under fire air is also used to increase combustion efficiency Air curtain incinerators can be built either above or below ground Some units have mesh screens to contain larger particles of fly ash but other add on pollution controls are normally not present The primary use of air curtain incinerators is in the disposal of wood wastes yard wastes and clean lumber however some of these incinerators are used to burn municipal solid waste or construction debris An air curtain incinerator should be reported in the EI by representing the pit or refractory wall chamber as the facility and as the fugitive emission point If a diesel blower is used to generate the air the diesel blower needs to be represented in the EI if it emitted 1 ton or more of any regulated polluta
14. already in the EI ensure that the appropriate facilities have a cooling tower group TCEQ publication RG 360A 10 m January 2011 A 19 Emissions Inventory Guidelines and profile and that all facility profile characteristics are complete If a cooling tower facility has the incorrect group type strike through the incorrect group type on the EI and write cooling tower and update the facility by attaching a completed Facility Information for Cooling Tower form to the EI be sure to write UPDATE FACILITY across the top of the form Each cooling tower facility must have a stack type emissions point This stack type emissions point should have e a stack diameter equal to the diameter e of the tower top for natural draft towers e of the fan for mechanical draft towers or e of an average fan for multicell towers e a stack velocity of 10 20 feet per second e atemperature ranging from ambient to 15 degrees Fahrenheit above ambient anonzero moisture content generally between 5 to 10 percent and e no horizontal discharge except for crossflow towers possibly When a permit lists multiple fans in a multicell tower use multiple stack type emissions points attached to a single cooling tower facility Cooling Tower Source Classification Codes The cooling tower should be represented on the EI with either an SCC of 38500101 for mechanical draft cooling towers or 38500102 for natural draft cooling towers
15. be used to determine emissions To claim credit for this program the documentation must demonstrate that all elements of the program are in place and were followed AVO factors can be found in the PDF document titled Emissions Factors for Equipment Leak Fugitive Components on the EAS s Web page at lt www tceq state tx us goto ieas gt Please note that an AVO inspection is different than a weekly physical inspection a weekly walkthrough inspection An AVO inspection is typically performed once per shift every four to eight hours versus once TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives per week and earns a reduction credit of up to 97 percent A weekly walkthrough inspection earns only a 30 percent reduction credit Determining Emissions from Unmonitored Components Emissions Determination Requirements Emissions from monitored components must be determined using actual monitoring data However for unmonitored components average emission factors may still be used to quantify emissions Quantifying Emissions Using Average Factors Average emission factors are divided into four categories e SOCMI e oil and gas production e refinery and e petroleum marketing terminals Within each category factors vary depending upon specific component type connectors valves pumps etc and material in service light liquid heavy liquid gas vapor or water light liquid For
16. components in liquid service choose between a heavy liquid emission factor and a light liquid emission factor Use the heavy liquid emission factor if the stream s vapor pressure is less than or equal to 0 044 psia at 68 F If the stream s vapor pressure is greater than 0 044 psia at 68 F use the appropriate light liquid emission factor Note that the average emission factors generally determine total hydrocarbon emissions Therefore determine the total VOC emissions by multiplying the calculated emission rates by the stream s percentage by weight of VOC compounds The EPA average emission factors for the industry types described in the following sections can be found in Protocol for Equipment Leak Emission Estimates EPA 453 R 95 017 available at the EPA Web site at lt www epa gov ttnchiel publications html gt SOCMI Emission Factors Use the SOCMI emission factors to determine the fugitive emissions from piping components at chemical plants or chemical processes within refineries SOCMI emission factors are divided into three categories TCEQ publication RG 360A 10 m January 2011 A 35 Emissions Inventory Guidelines A 36 SOCMI average emission factors SOCMI with ethylene emission factors and SOCMI without ethylene emission factors Use the SOCMI average emission factors which were developed to represent fugitive emission rates from all chemical plants for streams containing betw
17. following technical supplements are included in this appendix Technical Supplement 1 Select Combustion Sources addresses common problems and concerns regarding internal combustion engines turbines reciprocating engines and gasoline and diesel EAS engines external combustion sources burning natural gas and combined cycle turbines with heat recovery steam generators Technical Supplement 2 Cooling Towers will help you in determining the nature of the emissions from a cooling tower system in identifying some of the methods that may be used to quantify those emissions and in correctly reporting the emissions in the annual EI Technical Supplement 3 Equipment Leak Fugitives contains guidance for determining and reporting emissions from piping components at industrial facilities resulting from leaking seals or connections Technical Supplement 4 Flares contains guidance for estimating and reporting emissions from elevated flares Technical Supplement 5 Marine Facilities discusses stationary emissions from vessel cleaning material transfer and dockside sources such as particulate stockpiles silos VOC collection units loading racks TCEQ publication RG 360A 10 m January 2011 A 3 Emissions Inventory Guidelines and abatement devices All of these emissions sources must be reported in the dock owner s EI Technical Supplement 6 Aboveground Liquid Storage Tanks explores stationary emissions from storage tank breathing and wo
18. for all VOC species present in the cooling water If the monitoring system is insufficient in monitoring hydrocarbons the uncontrolled VOC emission factor should be used If the emissions are determined in this manner the determination methodology should be reported as A Emissions determined based on measurements from an air stripping method as outlined in the TCEQ Sampling Procedures Manual Appendix P are preferred This document is available at lt www tceq state tx us assets public implementation air sip miscdocs mef 115 AppP pdf gt When using such data to determine emissions assume that VOCs were present at the measured concentration for the entire period between samples If analytical test methods indicate that VOC measurements are below the minimum detection limit half of the detection limit must be used to calculate VOC emissions unless otherwise specified by a permit condition TCEQ or federal rule or commission order This method applies to monitoring that determines the total VOC emission rate either from a measurement of total VOCs or by a summation of measurements of all of the VOC species in the cooling water Where only a select few of the possible VOCs present in the cooling water are measured the AP 42 uncontrolled emission factor should be used to determine the total VOC emission rate from the cooling tower and the measurements of the select VOC species such as HRVOCs should be speciated in the emissions r
19. fugitives and the refinery fugitives Do I have to report emissions from components that are exempt from monitoring such as components less than 2 inches in diameter Yes The emissions from all components must be determined and reported regardless of monitoring exemptions based on size physical location or low vapor pressure Since these components are exempt from monitoring an approach based on determining average factors will typically be used and no reduction credits from monitoring may be applied I have a unit that was shut down part of the year Must I determine fugitive emissions from piping components for the entire year or just for the part of the year when the unit was operating The fugitive emissions from piping components should be determined for the entire year 8 760 hours unless the unit s lines were purged during the downtime TCEQ publication RG 360A 10 m January 2011 A 41 Emissions Inventory Guidelines A 42 I want to use correlation equations to determine the fugitive emissions from piping components May I get screening values for a certain percentage of components and use the average value to represent all other components No Correlation equations may only be used to determine emissions for those components with individual screening values If screening values are not determined for certain components a different calculation methodology should be used for these unmonitored components I have a
20. it is unacceptable to apply the inlet gas stream s VOC percentage to the vendor s TOC emission factor to obtain a VOC emission factor AP 42 Factors AP 42 provides both VOC and TOC emission factors Because complex oxidation reactions occur in the combustion chamber that significantly alter the composition of emissions it is unacceptable to apply the inlet gas stream s VOC percentage to the AP 42 TOC emission factor to obtain a VOC emission factor When using an AP 42 emission factor to determine emissions the most recent VOC emission factor should be used and the determination methodology should be reported as A Speciation To determine whether or not to speciate VOC emissions from an internal combustion engine see Chapter 4 Any source specific information about the VOC emissions composition should be used to speciate the emissions Submit the data and related information with the EI If no source specific information about the VOC composition exists the VOC emissions should be speciated using the AP 42 trace organic compounds emission factors that are graded C or better Divide each trace organic factor by AP 42 s VOC emission factor to obtain the contaminant s speciation ratio Multiply the source s total VOC emissions by each ratio to obtain that compound s emission rate The speciated VOC emissions that are at least 0 1 ton should be reported smaller rates may be included under VOC u conta
21. obtained with the instrument For unmonitored sources base determinations on average emission factors For detailed information on available emission factors and determination methods see the EPA documents Protocol for Equipment Leak Emission Estimates EPA 453 R 95 017 and Preferred and Alternative Methods for Estimating Fugitive Emissions from Equipment Leaks Emissions Inventory Improvement Program Document Series Volume II Chapter 4 November 1996 as well as the TCEQ Air Permits technical guide for equipment leak fugitives available at lt www tceq state tx us goto nsr_elf gt and the guidance available at the EAS Web page lt www tceq state tx us goto ieas gt Requirements for Determining Fugitive Emissions from Piping Components Emissions from instrument monitored components must be determined using the actual monitoring data gathered at a site Most LDAR program permit conditions require the retention of screening value data for all monitored components Therefore most sites with a monitoring program A 30 TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives will have the necessary data to use correlation equations to determine the fugitive emissions Specifically if a regulated entity is required by permit condition TCEQ rule or commission order to retain screening value data for its monitored components correlation equations must be used to determine emissions The EA
22. process knowledge and engineering calculations should be used to estimate emissions Since continuous monitoring methods measure the gas composition before destruction by the flare rather than the amount of emissions released to the atmosphere the determination methodology should not be reported as M for measured data or D for continuous emissions monitoring systems The determination methodology for uncombusted flared gas emissions should be reported as H for HRVOC monitoring when the actual flow rate and composition of the gas routed to the flare are obtained through a continuous monitoring system required by 30 TAC 115 725 26 When the actual flow rate and composition of the gas routed to the flare are obtained through a continuous monitoring system not required by 30 TAC 115 725 26 the determination methodology should be reported as B for material balance instead of H If the flow rate and composition of the gas routed to the flare are determined using process knowledge and engineering calculations the determination methodology TCEQ publication RG 360A 10 m January 2011 A 53 Emissions Inventory Guidelines for uncombusted flared gas emissions should be reported as S for scientific calculation SO Emissions SO emissions are calculated based on the amount of sulfur bearing compounds in the flared gas and on the appropriate destruction efficiency as dis
23. recovery steam generator HRSG or boiler will vary depending upon the operation of the units in question If the unit associated with the cogeneration turbine cannot operate independently from the turbine represent the units as one facility emissions point path noting in the path or facility comments that a duct burner or HRSG operates in conjunction with the turbine If the unit associated with the cogeneration turbine can operate independently from the turbine as is the case for most boilers represent the turbine as one facility and the associated unit as a separate facility If both the turbine and the associated unit vent to the same emission point create a common emission point for both facilities If the turbine can vent to a separate emission point that is not the emission point shared with the associated unit when it operates independently the emission point needs to be represented in the EI Create two paths for the turbine using one facility and two emission TCEQ publication RG 360A 10 m January 2011 A 15 Emissions Inventory Guidelines points one for the separate turbine stack and one for the stack shared with the associated unit The path for the associated unit that vents to the shared stack should be represented in the EI Expected Contaminants These facilities reported emissions should include all of the following TSP contaminant code 0000 e PMyjo contaminant code 20000 e PM25 contamina
24. to assume that the component was leaking at the measured concentration for the entire period since last monitored An acceptable engineering estimate would be that the component was leaking at the measured concentration for half the monitoring period plus the time needed to repair the component The EAS must approve any other method of determining leak durations When using the correlation equations to calculate emissions the components must be monitored at least once during the year Using monitoring data from a previous year to estimate future emissions is a difficult process If this is done sound engineering assumptions to support the calculations must be provided with the EI Table A 4 Determining Emissions Using Correlation Equations Screening value Determine emissions using Zero The default zero leak rate factor Nonzero and The screening value in the applicable correlation nonpegged equation Pegged The default 100 000 ppm pegged leak rate factor TCEQ publication RG 360A 10 m January 2011 A 33 Emissions Inventory Guidelines Detailed information about correlation equations can be found in Protocol for Equipment Leak Emission Estimates Unit Specific Correlation Equations If a regulated entity has developed its own set of unit specific correlation equations for its equipment leak fugitive components those equations may be used to determine emissions only if the equations sampling procedures an
25. to the atmosphere through a tank s pressure relief valve hatch or other openings or alternatively may be routed to a control device Flash emissions can also be associated with high intermediate and low pressure separators heater treaters surge tanks and accumulator operations however this supplement does not address emissions determinations for those sources TCEQ publication RG 360A 10 m January 2011 A 69 Emissions Inventory Guidelines A 70 While the composition of flash emissions varies flash gas emissions include VOCs HAPs and toxics Emissions Determination Methodologies Order of Preference Several different methods of determining flash emissions exist however there are specific constraints associated with each method The most appropriate method for determining flash emissions will depend upon the site specific process Acceptable determination methods for a given process should be evaluated upon whether the process parameters are consistent with the method s development and underlying assumptions General orders of preference for black oil and gas condensate systems are listed below However for a given system a more preferred method may not necessarily be applicable to a process based upon its specific parameters Specific constraints for each method are explained in detail in the following sections If the EAS determines that a determination method for a site specific process is unfounded then the EAS may
26. APPENDIX A TECHNICAL SUPPLEMENTS Disclaimer The Emissions Assessment Section EAS has developed technical supplements for several common emission sources The supplements are intended to provide guidance for determining and correctly reporting emissions from specific types of sources and may not cover every source at the site It is the responsibility of the owner or operator of a regulated entity to report the emissions from every source required to be included in its EI See Chapter 1 for information on reporting requirements These supplements reflect how certain processes work and how they generate emissions The supplements may change over time as a result of findings of scientific studies and as new information becomes available The EAS greatly appreciates any data information or feedback that may improve these supplements The methods discussed in this appendix are intended as an aid in calculating emissions Certain process or operational conditions may make alternate calculation methods equally acceptable if they are based upon and adequately demonstrate sound engineering principles or data It is the responsibility of the owner or operator of a regulated entity to use the best available method to determine and report the emissions that accurately reflect the conditions at his or her site Additional guidance regarding the acceptability of a given emissions determination method is available from the EAS at 512 239 1773 Misc
27. Expected Emissions Cooling towers operate in such a manner that they may emit particulate matter dissolved solids or chemicals entrained in the cooling water Cooling tower emissions fall into three categories particulate matter inorganic compounds and VOCs Any tower has the potential to emit all three of these emissions types in varying amounts depending on its service Particulate Matter Particulate emissions result from the presence of minerals or any dissolved or suspended solids in the cooling water Air flowing through the tower can entrain water droplets and carry them out of the cooling tower in a A 20 TCEQ publication RG 360A 10 m January 2011 Technical Supplement 2 Cooling Towers process referred to as drift Once these drift droplets leave the tower and evaporate they deposit dissolved or suspended solids as fine particulate matter PMjo or smaller Cooling towers are generally designed with drift eliminators typically mesh or a series of angled slates placed above the water inlet Note that despite its name a drift eliminator will reduce but not eliminate drift Inorganic Compounds Inorganic emissions may result from inorganic process fluids leaking into the cooling water or from water treatment chemicals or other additives used in the cooling water system The air flowing through the tower may strip these inorganic compounds from the water resulting in their emission Typical inorganic emissions may con
28. Fugitive Data Form found at the end of this supplement TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives Issues of Special Concern May I put the whole plant s fugitive emissions from piping components under one facility and emissions point In a relatively small plant such as a natural gas compressor station or a petroleum marketing terminal the fugitive emissions from the entire plant s piping components may be represented by one facility emissions point path For larger plants however it is generally more appropriate to report fugitive emissions under more than one facility There are two main items to consider when breaking fugitive areas into multiple facilities First if different process areas within a plant follow different leak detection and repair programs each area should be represented by a separate path to avoid confusion Second since stream composition may differ greatly between processes and may necessitate the use of different calculation methodologies fugitive emissions from separate processes should be reported under separate facilities Consider for instance a refinery with a process area for MTBE production Emissions determinations for the MTBE process area should use correlation equations or the SOCMI average emission factors as they are more appropriate than the refinery factors Separate facility emissions point paths should represent the MTBE process area
29. S has previously allowed the use of LDAR reduction credits applied to the EPA s average emission factors for annual emissions determinations However using actual leaking component data reflecting a site s actual leak fraction and LDAR program effectiveness will allow for more accurate emission determinations than using average emission factors with LDAR reduction credits Since all monitored sources should have individual screening values the use of average emission factors with LDAR reduction credits to determine emissions from monitored components is not allowed One exception is detailed under Quantifying Emissions from Components Monitored by an Audio Visual Olfactory Inspection later in this supplement Emissions Determination Methodologies Order of Preference The appropriate methodologies for determining VOC emissions from piping components are in order of preference e Unit specific correlation equations developed using bagging data in accordance with EPA guidelines code as M EPA correlation equations using screening values from an LDAR program code as A EPA industry appropriate average factors code as A The use of reduction credits from a LDAR program applied to the EPA s average factors for EI purposes is no longer allowed with few exceptions One exception is detailed under Quantifying Emissions from Components Monitored by an Audio Visual Olfactory Inspection later i
30. ailable The EAS greatly appreciates any data information or feedback that may improve this supplement The methods represented are intended as an aid in calculating emissions alternate methods may be equally acceptable if they are based upon and adequately demonstrate sound engineering assumptions or data Additional guidance regarding the acceptability of a given emissions determination method is available from the EAS at 512 239 1773 Introduction This technical supplement offers guidance on identifying quantifying and correctly reporting cooling tower emissions on the annual EI It does not address devices such as fin fan coolers and the cooling towers used exclusively in HVAC systems Definitions In this document cooling tower refers to the equipment that through the process of direct contact with atmospheric air reduces the temperature of water used to cool either process equipment or process fluid streams Cooling tower heat exchange system refers to the cooling tower and all associated heat exchangers pumps and ancillary equipment where water is used as a cooling medium to transfer heat from the process fluids to the water Cooling Tower Structure Each cooling tower in VOC service must be represented as a facility in the EI For a multicell tower represent the entire tower as a single facility To add a cooling tower in VOC service to the EI use the Facility Information for Cooling Tower form For cooling towers
31. ain type of engine PM o filterable 0 0095 Ib MMBtu PM 5 filterable 0 0095 lb MMBtu PM condensable 0 00991 Ib MMBtu Then the correct particulate emission factor for this engine type would be the sum of the PM 5 filterable and the PM condensable factors or 0 01941 Ib MMBtu If the engine consumed 35 000 MMBtu of fuel during the year then its particulate emissions would be 1 ton sp 0 0104 2 6 95 909 CO x 0 3395 tons year MMBtu year 2000 Ib The correct way to report these emissions is shown in Table A 1 TCEQ publication RG 360A 10 m January 2011 A 7 Emissions Inventory Guidelines Table A 1 Reporting Particulate Emissions Contaminant Code Contaminant Annual Emissions 10000 Part unclassified 0 3395 tons 20000 PM jo unclassified 0 3395 tons 39999 total PM gt 5 0 3395 tons VOC Emissions A 8 Determining speciating and reporting VOC emissions have caused some confusion in previous years Please read the information in this section carefully VOC emissions may be determined using a combination of stack test data vendor data and AP 42 emission factors Each methodology is discussed separately in the following sections each section contains methodology specific speciation instructions Stack Test Data When using stack test data to determine VOC emissions the results of the stack test should be verified to ensure that the test measured VOCs rather than total hydrocarbons If it did
32. an internal floating roof Sum these two emission rates to determine degassing emissions For a drain dry floating roof tank degassing emissions can be determined by a two part process First use the TANKS program to determine emissions for one turnover Next to approximate the vapor displaced from the space under the floating roof determine the emissions from the tank modeled as a fixed roof tank with a tank height equal to the height of the deck legs Sum these two emission rates to determine degassing emissions For either fixed or floating roof tanks with a liquid heel the heel may be a continuing source of vapors that can generate emissions Therefore liquid heel emissions should be accounted for when determining degassing emissions Cleaning Sludge Handling Most aqueous sludges are about 80 percent to 90 percent water by weight A conservative approach for determining emissions from sludge cleaning is to assume the sludge is 80 percent water the remainder is assumed to be VOCs and emitted As an alternative the actual sludge moisture content can be determined Special Considerations when Quantifying Emissions When determining storage tank emissions the following should be considered Pressure Tanks Pressure tanks are designed to handle pressures significantly higher than atmospheric pressure Two classifications of pressure tanks exist low pressure and high pressure tanks The API defines low pressure tanks as thos
33. ation If samples were tested for VOCs then use the measured data to speciate emissions For more information on speciation requirements see Chapter 4 For guidance regarding method detection limits and speciated compounds follow the general guidance outlined in Minimum Detection Limits Chapter 4 Supporting Documentation Include documentation with the EI that supports and validates the emissions reported in the inventory The relevant supporting documentation for cooling towers includes but may not be limited to representative samples of the following types of data e VOC test results especially from times when leaks were discovered e cooling water and process fluid pressure readings for systems that maintain cooling water at a pressure at least 5 psi greater than the process fluid pressure throughout the entire cooling tower heat exchange system e annual water treatment chemical usage data for all chlorinated or brominated chemicals e annual and daily flow rate for cooling water and TCEQ publication RG 360A 10 m January 2011 A 25 Emissions Inventory Guidelines e emission rates calculated from measured data Issues of Special Concern A 26 What if I share a cooling tower with another company Emissions should be reported by the regulated entity who owns the cooling tower Please call the EAS for additional guidance about an individual situation Are there any circumstances when I may use the AP 42 contro
34. ation from devices such as lower explosive limit detectors chlorine residual measurements and total organic carbon measurements do not qualify as adequate monitoring or control technology therefore the AP 42 controlled VOC emission factor should not be used TCEQ publication RG 360A 10 m January 2011 Technical Supplement 2 Cooling Towers Annual and Ozone Season Rates If measured data are available for a cooling tower calculate the reported emissions using actual rather than average test data Use test data from each sampling event to determine emissions released since the prior sampling event Sum the emissions obtained from the different sampling periods to obtain the annual total If analytical test methods indicate that VOC measurements are below the minimum detection limit that is undetected then half of the detection limit must be used to calculate VOC emissions unless otherwise specified by permit condition TCEQ or federal rule or commission order For example suppose that tests are performed weekly to determine a cooling tower s VOC emission rate Using the test results from each week and the associated water flow for the seven days preceding the sample time calculate the total emissions for each seven day period during the year then sum those weekly emissions to arrive at the annual total To obtain ozone season emission rates determine the emission rates in pounds per day during June July and August Speci
35. c diameter smaller than 2 5 Hence all particulate emissions from these sources should be reported as TSP PMjo and PM 5s Note that AP 42 provides three particulate emission factors PM total PM condensable and PM filterable Use the PM total factor which can also be obtained by summing the PM condensable and PM TCEQ publication RG 360A 10 m January 2011 Technical Supplement 1 Combustion Sources filterable factors to determine boiler particulate emissions Report these emissions as TSP contaminant code 10000 as PM contaminant code 20000 and as PM 5 contaminant code 39999 VOC Emissions VOC emissions may be determined using stack test data AP 42 emission factors or both Each methodology is discussed separately in the following sections and is followed by instructions on speciation Stack Test Data When using stack test data to determine VOC emissions verify that the test measured VOCs rather than total hydrocarbons If the test did measure VOCs the results should be used to determine the VOC emissions and the determination methodology reported as M If the stack test measured total hydrocarbons the VOC emissions will need to determined by multiplying the hydrocarbon emission factor by the following ratio AP 42 VOC emission factor AP 42 TOC emission factor The determination methodology should be reported as S Because complex oxidation reactions occur in the combustion chamber that s
36. category listed above To accurately use these equations classify the storage tank into one of the above categories Care must be taken when classifying a tank as drain dry Both AP 42 Chapter 7 and API TR 2567 state that a tank is only a drain dry tank if all of its free standing liquid has been removed The following tank configurations qualify as tanks with a partial liquid heel according to API TR 2567 e tanks that drain to a sump that retains a liquid heel e tanks whose sumps have baffles or similar fittings that retain liquid or e flat bottom tanks whose contents have been removed by a vacuum truck since liquid typically will still remain in irregular surfaces along the tank bottom For each tank category listed above AP 42 Chapter 7 publishes different saturation factors that have been validated through API field studies to use in the landing loss equations These saturation factors represent the stratification of vapors in the vapor space underneath the floating roof therefore no modification to these saturation factors based upon tank shell height is necessary Required Data for Determining Landing Loss Emissions After correctly determining the tank type collect the following information about the tank and its contents for each episode when the roof is landed e tank diameter e tank color e height of the vapor space under the floating roof e height of the stock liquid e atmospheric pressure at the tank s locat
37. chemical or mixture data into the TANKS program s chemical database use these new chemical data to generate emissions reports Similarly detailed information on the number and physical characteristics of the tank fittings should be used in the detailed fittings selection in the Physical Characteristics portion of the TANKS program The typical fittings selection should not be used The program user s manual available at lt www epa gov ttn chief software tanks index html gt contains detailed instructions for adding TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks or modifying chemicals chemical mixtures and tank fittings as well as general information on how to use the software Obtaining Accurate Emissions Determinations from the E amp P TANK Program Accurate data input is essential to obtaining valid emissions determinations when using the E amp P TANK program The program has default settings for many input variables including a geographic database option for crude oil Using the default settings can result in inaccurate or invalid emissions determinations Therefore the user should use site specific data to obtain the greatest accuracy Because the E amp P TANK program gives only an annual emissions amount use caution when determining ozone season emissions One option for estimating ozone season emissions is to enter the monthly throughputs for only the ozo
38. crude oil storage and loading facility May I use the emission factors for bulk terminals No If monitoring data for the fugitive components exist then the monitoring data must be used to determine emissions in accordance with the guidance in this supplement In the absence of monitoring data use the oil and gas production average emission factors to determine the emissions The bulk terminal average emission factors were developed specifically for gasoline and gasoline product loading operations For crude oil storage and loading the oil and gas production emission factors would be more appropriate I have an LDAR program Is there any way to represent this on my emissions inventory An LDAR program can be represented in the EI by adding a CIN with an abatement code of 800 Since the LDAR reduction credits can no longer be applied to average factors for emissions determinations a control efficiency for this type of CIN is not required How do I find out if any new fugitive emission factors for piping components have been developed or approved by the TCEQ Review the PDF document Emissions Factors for Equipment Leak Fugitive Components available on the EAS s Web page at lt www tceq state tx us goto ieas gt Do I have to report emissions of nonreactive compounds Nonreactive compounds like methylene chloride and acetone are still considered air contaminants and should be reported This is particularly important if a nonreactiv
39. culate TSP matter and PMjo9 See Chapter 4 Particulate Emissions for more details In the past some confusion has arisen from AP 42 s representation of three particulate emission factors PM jo filterable PM gt 5 filterable and PM condensable TSP consists of condensable particulate matter and filterable particulate matter therefore the emissions from condensable particulates and from filterable particulates must be determined to calculate the cumulative particulate emissions However the manner used to sum these emission factors is not straightforward Since all particulate matter emitted from internal combustion engines is PM or smaller the PMjo filterable and PM 5 filterable emission factors are equivalent those two factors represent the same set of particulate emissions In calculating the TSP emissions use one of the filterable emission factors when attempting to obtain the cumulative emission factor To calculate particulate emissions add the condensable emission factor and one of the two filterable emission factors to obtain the cumulative TSP emission factor Use this cumulative TSP emission factor to determine all particulate emissions Report the emission rate as follows e total suspended particulate contaminant code 70000 e PMyjo contaminant code 20000 and e PM 5 contaminant code 39999 Example Suppose that AP 42 shows the following emission factors for particulate matter from a cert
40. cussed previously For example assume that 100 pounds per hour of flared gas composed of 80 percent butane and 20 percent H2S is burned in a flare that satisfies 40 CFR 60 18 The hourly uncombusted flared gas emissions would be 1 6 pounds of butane and 0 4 pounds of H3S In addition the flare creates SO from the H2S Determine the SO emissions as follows lb H S Ib SO lb SO BPG Rigs O on 2 36 9 2 20 x x 36 hour 34 lb H S lb mole hr Note that as the criteria of 40 CFR 60 18 were met a 98 percent destruction efficiency was assumed The determination methodology for SOz emissions should be reported as B for material balance Annual and Ozone Season Rates A 54 Typically flared gas flow rate and composition are highly variable therefore calculations of flare emissions need to take this variability into consideration In general emission determinations should not be based on annual average conditions Instead calculate emissions for short time segments when flare flow rate and composition are relatively constant and then sum those short term emissions to obtain the actual annual total For example if hourly flow rates and composition data are available then calculate hourly emissions lb hr and sum all hourly rates to obtain the annual total If only weekly data are available then calculate weekly average emissions and sum those to obtain the annual total These principles are especially importa
41. d may sometimes require exercising scientific judgment For example when using the results of a one time performance test the test conditions should be compared to the flare s actual operating conditions during the inventory year to determine whether the test accurately represents the flare s performance If test conditions do not accurately model flare operation then engineering determinations based on detailed process evaluation may provide the best data NO and CO Emissions To calculate NO and CO emissions the net heating value of the flared gas must be known Using the actual short term flared gas composition and flow rate data for the inventory year calculate the net heating value of the flared gas and the total heat release for each short time period Use these total heat release data in conjunction with the appropriate emission factors from TCEQ Air Permits guidance to determine NO and CO emissions for each time segment Since the calculated net heating value of the gas and the assist gas type will determine the appropriate emission factors carefully select the correct factors for each flare from Table A 6 Calculate emissions using the most accurate data for the gas flow rate and composition available See Flared Gas Flow Rate and Composition earlier in this supplement for more information on preferred data Table A 6 TCEQ Air Permits Flare Emission Factors Assist Waste Gas Stream C
42. d all related procedures and data comply with EPA Reference Method 21 and the guidance in Protocol for Equipment Leak Emission Estimates When using company developed correlation equations supply supporting documentation indicating the basis for these equations Also if the site specific equations do not take into consideration components with screening values of zero the EAS may require the use of the EPA s default zero leak rates Likewise if the site specific equations do not include components with pegged screening values the EAS may require the use of the EPA s pegged leak rates Quantifying Emissions from Components Monitored by an Audio Visual Olfactory Inspection A 34 For odorous or toxic inorganic compounds an AVO inspection may be required by TCEQ rule commission order or permit condition Generally an AVO inspection program may only be applied to inorganic compounds that cannot be monitored by instrument In limited instances the AVO inspection program may be applied to extremely odorous organic compounds such as mercaptans Note the trace amounts of mercaptans present in natural gas are not sufficient to allow for an AVO inspection However a plant that manufactures mercaptans would be eligible since the process streams contain a sufficient concentration of these compounds If no monitoring or screening data exist for AVO monitored components then average emission factors with AVO reduction credits applied can
43. d in Section 2 3 4 of Protocol for Equipment Leak Emission Estimates To develop these TCEQ publication RG 360A 10 m January 2011 A 37 Emissions Inventory Guidelines equations it is necessary to use a monitoring instrument that could detect the inorganic compounds in question Note that it also would be necessary to use a monitoring instrument that could detect the inorganic compounds in question to apply either EPA developed correlation equations or screening range emission factors If monitoring data are not available calculate uncontrolled fugitive emissions using the industry specific emission factors discussed previously Although these VOC emission factors were not developed specifically for use with inorganic compounds they are presently the best data available for determining inorganic fugitive emissions from piping components Quantifying Emissions for Nontraditional Components Emissions from nontraditional piping sources should be calculated and included in all emissions inventories While these sources have not historically been included recent scientific studies and equipment monitoring have indicated that these components are a source of emissions Although component specific emission factors do not exist for most nontraditional components the TCEQ has identified appropriate substitute emission factors based on component leak potential and leak mechanism similarity These emission factors are listed in Table A 5
44. determine and correctly report emissions from marine facilities This supplement does not supersede or replace any state or federal law rule or regulation This guidance reflects the current understanding of how marine facilites work how they generate emissions how they are monitored or tested and what data are available for emissions determination This supplement may change over time as a result of findings of scientific studies and as new information becomes available The EAS greatly appreciates any data information or feedback that may improve this supplement The calculation methods represented are intended as an emissions calculation aid alternate calculation methods may be equally acceptable if they are based upon and adequately demonstrate sound engineering assumptions or data For additional guidance regarding the acceptability of a given emissions determination method contact the EAS at 512 239 1773 Introduction This technical supplement offers guidance on identifying quantifying and correctly reporting marine facility emissions on the annual EI Marine facility emissions must be reported as part of the annual routine EI The owner or operator of the onshore facilities does not own or operate the marine vessel itself but does operate most of the activities resulting in vessel emissions while the vessel is docked Therefore the owner or operator of the onshore facilities is responsible for reporting dock and docksid
45. e Griswold and Ambler GOR Chart is not an acceptable method for determining flash emissions for EI purposes The Griswold Ambler method cannot determine VOC emissions and cannot be used to estimate the composition of flash emissions In particular it cannot distinguish between VOC and HAP emissions Determining Emissions from Landing Losses A 74 Introduction Landing losses occur from floating roof tanks whenever a tank is drained to a level where its roof lands on its deck legs or other supports including roof suspension cables When a floating roof lands on its supports or legs it creates a vapor space underneath the roof Liquid remaining in the bottom of the tank provides a continuous source of vapors to replace those expelled by breathing in the case of internal floating roof tanks or wind action in the case of external floating roof tanks These emissions referred to as standing idle losses occur daily as long as the tank roof remains landed Additional emissions occur when incoming stock liquid fills a tank with a landed roof the incoming liquid not only displaces those vapors remaining under the floating roof but also generates its own set of vapors that are displaced during the filling process These two types of emissions are collectively referred to as filling losses For a given roof landing event total landing loss emissions are therefore the sum of the filling losses and the daily standing idle losses over the e
46. e assumption that component leaks will not grow in the future a questionable engineering assumption that will likely result in underestimation of emissions In the case of skip period provisions in a permit it is permissible to use data from the last monitoring period in the correlation equations For future leaking components use leaking component screening values before any repairs are done Since there is a history of monitoring and monitoring will occur in the future the snapshot as it were taken before repairs should reasonably mirror any future monitoring Because there is no way to estimate the amount of time a component will leak in the future the most conservative estimate would be to assume any leaking component will do so for an entire year If a different method to estimate the emissions is used document valid engineering assumptions to support the calculations In the past I used screening range leak no leak emission factors to determine emissions from my fugitive area May I continue to use this method The correlation equations should be used to determine emissions from the fugitive area if screening value data from a monitoring program are available If a monitoring program does not retain screening value data emissions must be determined using the best available method If the screening range TCEQ publication RG 360A 10 m January 2011 A 43 Emissions Inventory Guidelines emission factors are used to
47. e compound has an associated allowable emission rate Nonreactive fugitive emissions from piping components should be calculated in the same way as VOC fugitive emissions TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives For my permit I used the EPA s average emission factors with LDAR reduction credits to determine my fugitive emissions from piping components Can I use this approach to report these emissions in the emissions inventory No All monitored components should either have limited data for leaking components or preferably have individual screening values Since using this monitoring data with correlation equations or screening range emission factors will provide a more accurate determination of a site s emissions the use of LDAR reduction credits applied to average emission factors for emissions determinations will not be allowed I monitor my connectors only once every four years based on skip period provisions in my permit For years where the connectors are not monitored should I use the average emission factors with no reductions applied to estimate my emissions Or can I apply the correlation equations using the data from the last monitoring period Normally the EAS would require components to be monitored at least once during the current inventory year to use the correlation equations Using monitoring data from previous years to predict future emissions requires th
48. e marine vessel emissions in the annual EI This is consistent with the long standing approach of reporting truck loading and cleaning emissions in the truck terminal or cleaning facility owner s inventory Several categories of facilities are associated with marine operations including e onshore process units or equipment performing a function associated with dockside marine vessels e g solid material stockpiles silos tanks and abatement devices e the dock and all of its associated equipment e g conveying lines piping valves pumps hoses and blowers and e dockside marine vessel loading and unloading cleaning and degassing and abrasive blasting and painting A marine vessel is considered dockside if it is in any way connected to the shore This includes vessels TCEQ publication RG 360A 10 m January 2011 A 57 Emissions Inventory Guidelines connected to the dock connected to a vessel that is connected to the dock or connected directly to the land Because onshore process units and equipment are addressed elsewhere in 2010 Emissions Inventory Guidelines this technical supplement addresses only dock and dockside marine vessel emissions This supplement does not address the structural representation of marine operations in the inventory For guidance consult Chapter 3 Multiple Air Permits draft guidance documents are referred to in this supplement The documents are available by contacting TCEQ Air Permits person
49. e operating in the range of just above atmospheric pressure to 15 psig high pressure tanks are those operating at pressures above 15 psig High pressure tanks are considered to be closed systems that prevent routine breathing and working loss emissions However routine fugitive emissions from piping components associated with high pressure tanks as well as any non routine emissions should be reported in the EI TCEQ publication RG 360A 10 m January 2011 A 77 Emissions Inventory Guidelines A 78 Low pressure tanks can experience breathing and working losses While these emissions are usually less than a similar atmospheric tank would experience these emissions should be quantified and reported within the EI according to the guidance outlined in Chapters 3 and 4 Since the TANKS program uses equations developed under atmospheric conditions it does not accurately model emissions from low pressure tanks Instead use API Bulletin 2516 Evaporation Loss from Low Pressure Tanks to determine breathing and working losses from low pressure tanks Nitrogen Blanketed Tanks Typically storage tanks are blanketed with nitrogen or other inert materials to reduce the risk of fire to reduce water acquisition by hygroscopic materials or to prevent corrosion However nitrogen blanketing of an atmospheric storage tank does not reduce the tank s breathing or working loss emissions note air is approximately 78 percent nitrogen by volume
50. ed as Q Testing conducted with a portable analyzer does not qualify as stack testing therefore the emissions determination methodology should not be reported as measured M If the stack test results from an identical unit are used to determine the emissions the emissions determination methodology should be reported as estimated E Note that material balance B is not explicitly mentioned in the list because of its limited applicability in determining emissions from combustion sources If these methodologies will not accurately represent a source s emissions contact the EAS for further assistance SO Emissions If any sulfur is present in a source s inlet gas the source will emit sulfur dioxide as a product of combustion CEMS PEMS and stack test data are the preferred order when identifying the determination methodology for determining the SO emissions In lieu of using a vendor or AP 42 SO emission factor the SO2 emissions should be determined using material balance based upon the combusted fuel s sulfur content Particulate Emissions Combustion sources emit particulate matter Furthermore particulate matter emitted from internal combustion engines has an aerodynamic A 6 TCEQ publication RG 360A 10 m January 2011 Technical Supplement 1 Combustion Sources diameter smaller than 2 5 microns Thus all particulate emissions from these sources should be reported as PM 5s total suspended parti
51. edict a component s leak rate Averaged screening values should not be used to determine emissions For each component with a screening value of zero note that although the correlations predict a leak rate of zero for screening values of zero the EPA data suggest that this prediction is incorrect The EPA has established a default zero leak rate factor that should be applied to each component whose screening value was zero For each component with a pegged screening value use the EPA developed default 100 000 ppm pegged leak rate factor Note that if a pegged value of 10 000 ppm is indicated i e the instrument will not quantify the screening value between 10 000 ppm and 100 000 ppm then use the default 100 000 ppm pegged leak rate factor not the default 10 000 ppm rate factor This information is summarized in Table A 4 Since a component s screening concentration may vary from one monitoring period to another emissions for each period should be based upon each component s screening concentration for that period These period specific emission rates should then be summed to obtain an annual emissions rate For example if components are monitored quarterly each component s quarterly screening value should be used to determine quarterly emissions and then the quarterly emission rates summed to obtain the component s total annual emissions When determining a component s leak duration it would be most conservative
52. een 11 percent and 85 percent ethylene For streams containing more than 85 percent ethylene use the SOCMI with ethylene emission factors For streams containing less than 11 percent ethylene use the SOCMI without ethylene emission factors Oil and Gas Production Emission Factors The oil and gas production emission factors are based on data from piping component leaks from oil and gas production sites gathered by the American Petroleum Institute and evaluated by the EPA These factors include four different equipment service categories gas heavy oil less than 20 API gravity light oil greater than 20 API gravity and water light oil water streams in light oil service with a water content between 50 percent and 99 percent Refinery Emission Factors Use refinery emission factors to determine the fugitive emissions from piping components for a refinery process For a chemical process located within a refinery that is not specifically considered a refinery process for example an MTBE production unit use the SOCMI factors rather than the refinery factors to calculate emissions Petroleum Marketing Terminal Emission Factors Use the emission factors for petroleum marketing terminals to determine the fugitive emissions from piping components at gasoline distribution facilities that are one step removed from local gasoline stations and other end users Do not use these emission factors to determine the fugitive emissio
53. ellaneous VOC Sources One of the goals of the EAS is to identify sources that are failing to report or underreporting their VOC emissions The sources that fall into this category include but are not limited to casing head gas releases coking units confined entry ventilation and Merox units The EPA has released a draft document titled Emission Estimation Protocol for Petroleum Refineries that is currently under review Once finalized this document may provide guidance on determining emissions from coking units and Merox units The TCEQ is not aware of any additional specific guidance that is readily available to estimate the emissions from these types of sources If these sources are present at the site the sources should be represented in the EI and the emissions should be determined and reported in the EI using the best available emission estimation methodologies Casing Head Gas Releases Casing head gas is unprocessed natural gas and other hydrocarbon vapors that emerge at the casing head fitting when crude oil is pumped to the surface of a well During normal operating conditions the casing head TCEQ publication RG 360A 10 m January 2011 A 1 Emissions Inventory Guidelines fitting is tight and no vapors leak into the atmosphere When the casing head gas is vented the emissions should be included in the EI Coking Units Coking is a severe method of thermal cracking used to break heavy long chained hydrocarbons into lighter
54. ene and 20 percent butane by weight speciated VOCs would be reported as 0 4 pound per hour toluene 1 2 pounds per hour xylene and 0 4 pound per hour butane For flares subject to HRVOC regulations determine speciated uncombusted flare gas emissions according to the requirements including destruction efficiencies outlined in 30 TAC 115 725 Supporting Documentation Flare emissions depend heavily on a flare s destruction efficiency Supply detailed sample calculations showing the basis of flare destruction efficiencies and emissions For each flare in HRVOC service indicate Yes on the HRVOC Service characteristic Regardless of the county location of the regulated entity if any individual gas stream routed to the flare contains more than 5 percent by weight of aggregate highly reactive volatile organic compounds HRVOCs ethylene propylene all isomers of butene and TCEQ publication RG 360A 10 m January 2011 A 55 Emissions Inventory Guidelines 1 3 butadiene the flare is considered to be in HRVOC service for EI purposes In addition the EAS may request data for those times when the flare did not satisfy 40 CFR 60 18 criteria These data include but are not limited to e the date and time of the period e the flare emissions point e waste gas and supplemental fuel flow rate in scfm e waste gas and supplemental fuel composition in volumetric percentages e the Btu scf value for each compo
55. eporting and subtracted from the total VOC emission rate derived from AP 42 Since this method measures the amount of air strippable VOCs present in the cooling water the determination methodology should be reported as M for measured Measured cooling water VOC concentrations and flow rate data may be used to determine the VOC emissions assume that VOCs were present at the measured concentration for the entire period between samples If analytical test methods indicate that VOC measurements are below the minimum detection limit half of the detection limit must be used to TCEQ publication RG 360A 10 m January 2011 A 23 Emissions Inventory Guidelines A 24 calculate VOC emissions unless otherwise specified by a permit condition TCEQ or federal rule or commission order This method applies to monitoring situations where a total VOC emission rate can be determined either from a total VOC measurement or a summation of measurements of all of the VOC species in the cooling water Please note that the application of TOC or VOC concentration to water drift does not properly account for the VOC emissions stripping or flashing out of the water and should not be used Concentrations should be applied to the flow circulation rate data to determine emissions For cases where only a select few of the possible VOCs present in the cooling water are measured the AP 42 uncontrolled emission factor should be used to determine the tota
56. estimate the emissions supply valid engineering assumptions to support the calculations The TCEQ accepts the use of the correlation equations for screening values between zero and 100 000 ppm If my instrument indicates nonpegged screening values above 100 000 ppm can I use the correlation equations for those readings For EI purposes the TCEQ currently accepts correlation equations as an acceptable method to determine emissions where the screening value is above 100 000 ppm My site does not fit specifically into one of the four categories of EPA average emission factors What emission factors should I use The most representative emission factors should be used For example a chemical storage and loading facility would select the SOCMI emission factors instead of the petroleum marketing terminal or oil and gas emission factors Both the type of product and the type of process should be considered when selecting the most appropriate factor References Texas Commission on Environmental Quality 2005 Emissions Factors for Equipment Leak Fugitive Components TCEQ Industrial Emissions Assessment Section draft document Available online at lt www tceq state tx us goto ieas gt Accessed October 28 2010 U S Environmental Protection Agency 1995 Protocol for Equipment Leak Emission Estimates EPA 453 R 95 017 Available online at lt www epa gov ttnchie1 publications html gt Accessed October 28 2010 1996
57. f the liquid streams are warmer than ambient temperature see Technical Supplement 6 for information on hot product storage to determine the tank s routine emissions Additional emissions from inert gas stripping should be calculated using sound engineering principles and data TCEQ publication RG 360A 10 m January 2011 Appendix A Introduction Glycol Dehydration Operations Glycol dehydration units are used to remove water from natural gas streams to prevent the formation of hydrates and corrosion in the pipeline Once the glycol is saturated with water the rich glycol is pumped to a glycol reboiler heater to be regenerated and reused When the glycol is heated the VOCs including BTEX and other HAPs and water are boiled off and may be released to the atmosphere through the glycol still vent Whether the GRI GLYCalc program or a material balance based on a rich lean analysis is used to determine emissions an extended gas analysis is necessary for an accurate estimate The gas analysis must be speciated for each chemical including but not limited to BTEX and HAPs If the process operations include a flash tank the flash tank emissions should be included in the EI Controls for the regenerator and flash tank vents can be accounted for in the GRI GLYCalc program When the GRI GLY Calc program is used to determine the emissions include the Aggregate Summary Emission Report in the sample calculations Technical Supplements The
58. he bonnet and stem e diaphragm type valves e seal welded magnetically actuated packless hermetically sealed control valves Connectors Take a 100 percent control credit if the connections are welded together around their circumference so that the flanges cannot be unbolted Compressors Take a 100 percent control credit if a compressor is designed with enclosed distance pieces and if the crankcase vents to a control device Double Mechanical Seals Take a 75 percent control credit for any component employing double mechanical seals Speciation Use current gas or liquid process stream analysis or both to speciate the fugitive emissions from piping components Remember to speciate HAP emissions greater than 0 1 tpy for all sources In nonattainment counties supply HRVOC speciation to 0 1 tpy For more information about speciation requirements for the emissions inventory see Chapter 4 Supporting Documentation A 40 Include representative sample calculations for each fugitive area including a list of the components where a 100 percent control credit has been applied with a footnote describing the specific control method If screening range emission factors are used the EAS may require the submission of supporting documentation to verify that a permitted monitoring program is not required to retain screening value data In addition if more than 5 tons was emitted at a fugitive area during the year complete and submit the
59. hnical Supplement 6 Aboveground Storage Tanks If the tank is not well insulated daily variations in liquid surface temperatures may be observed The Minimum and Maximum Liquid Surface Temperatures should be input to estimate breathing losses Ensure that the TANKS program has the appropriate information for estimating vapor pressure at the desired temperature in its chemical database For example if the program uses Option 1 in the chemical database for estimating vapor pressure for temperatures from 40 to 100 F and the desired temperature is over 100 F the program will not extrapolate the vapor pressure to the higher temperature but will instead calculate a vapor pressure at 100 F Options 2 3 or 4 in the chemical database should be used for estimating vapor pressures at temperatures greater than 100 F Tanks Storing Hot Products If hot products materials with a temperature above the ambient temperature are put into an unheated tank ambient meteorological data will not properly model the tank s true emissions If the TANKS program is used the tank should be treated as a heated tank see section above using the following guidance For material cooling the Minimum and Maximum Liquid Surface Temperatures should be entered to estimate breathing losses The elevated stock liquid temperature should be entered for the liquid bulk temperature and the vapor space and liquid surface temperature ranges should be determined using the
60. ically the minimum inputs needed for the model are e separator oil composition e separator temperature and pressure e sales oil API gravity and Reid vapor pressure RVP e sales oil production rate and e ambient temperature and pressure Since separator oil composition is a key input in the model E amp P Tank includes a detailed sampling and analysis protocol for separator oil E amp P Tank also allows users to input detailed information about tank size shape internal temperatures and ambient temperatures therefore the software can produce more precise emissions determinations This flexibility in model design allows users to employ the model to match site specific information The E amp P Tank software is available at lt www global ihs com gt Vasquez Beggs Correlation Equation The Vasquez Beggs correlation equation was developed in 1980 as part of a University of Tulsa research project More than 6 000 samples from oil fields worldwide were used in developing correlations to predict oil properties The Vasquez Beggs correlation equation determines the gas oil ratio of a hydrocarbon solution from user inputted variables this GOR can then be used in conjunction with product and process parameters to determine flash emissions This method was designed for gases dissolved in crude oils and is most appropriate for use on upstream operations such as stock tanks at wellheads oil and gas production batteries and for blac
61. ight and vapor pressure e sampling analysis e all supporting data used to calculate the flash losses including identification of the determination method sample analysis API gravity density of liquid petroleum gas oil ratio gas gravity molecular weight of stock and VOC percentage by weight of both the stored liquid and flash gas and e all other information necessary to determine emissions For More Information A 82 Additional guidance for storage tanks is available at the EPA s Web site lt www epa gov ttn chief faq tanksfaq html gt While those questions are not reproduced here due to space considerations they address such topics as underground storage tanks vapor balanced tanks tanks with roof geometries other than a cone or a dome indoor storage tanks and tanks storing a two phase liquid TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks References American Petroleum Institute 1962 Evaporation Loss from Low Pressure Tanks Bulletin 2516 2000 Production Tank Emissions Model E amp P Tank Version 2 0 Publication 4697 2005 Evaporative Loss from Storage Tank Floating Roof Landings Technical Report 2567 New Mexico Environment Department Air Quality Bureau Frequently Asked Questions Tank Flashing Emissions Available online at lt www nmenv state nm us aqb FAQ html gt Accessed October 28 2010 Oklahoma Department of Environmental Q
62. ignificantly alter the composition of emissions it is unacceptable to apply the inlet gas stream s VOC percentage to the stack test TOC emission factor to obtain a VOC emission factor Vendor Data When using vendor data to determine VOC emissions verify that the vendor s emission factor refers to VOCs rather than total hydrocarbons If it does the VOC emissions can be calculated and the determination methodology should be reported as V If the vendor s emission factor refers to total hydrocarbons the VOC emissions should be determined by multiplying the hydrocarbon emission factor by the ratio AP 42 VOC emission factor AP 42 TOC emission factor The determination methodology should be reported as S Because complex oxidation reactions occur in the combustion chamber that significantly alter the emissions composition it is unacceptable to apply the inlet gas stream s VOC percentage to the vendor s TOC emission factor to obtain a VOC emission factor AP 42 Factors AP 42 provides both VOC and TOC emission factors Because complex oxidation reactions occur in the combustion chamber that significantly TCEQ publication RG 360A 10 m January 2011 A 13 Emissions Inventory Guidelines A 14 alter the emissions composition it is unacceptable to apply the inlet gas stream s VOC percentage to the AP 42 TOC emission factor to obtain a VOC emission factor When using an AP 42 emission factor to determine emissio
63. ing displaces the residual nitrogen pad from the marine vessel compartment and saturates the vapor space with product vapor prior to loading Calculate emissions from gas freeing or gas conditioning using the ideal gas law and the actual pressure concentration and vessel volume data Since the ideal gas law is a first order scientific principle the determination methodology should be reported as S for scientifically calculated Loading and Unloading Bulk Solid Materials Fugitive dock emissions occur at the loading and unloading operations for bulk solid materials During loading emissions also occur from the entrainment of solids during displacement of the vessel compartment air space Material transfer methods determine where and how particulate matter is emitted Emissions from such transfer methods as pneumatic systems clamshell buckets drag chains belt conveyors manual operations or a combination of these methods should be determined following the detailed guidance in the Air Permits document Dockside Vessel Emissions If a material type is explicitly addressed in air permits guidance the determination methodology should be reported as A If the material type is not explicitly addressed use the method for the most closely related material and report the determination methodology as E for estimated Degassing and Cleaning Vessel Compartments A 60 Cleaning operations remove residual material fro
64. ion e average temperature of the vapor and liquid below the floating roof TCEQ publication RG 360A 10 m January 2011 A 75 Emissions Inventory Guidelines e physical and chemical properties of the stored liquid such as density molecular weight and vapor pressure e physical and chemical properties of the liquid that the tank is refilled with if different from the previously stored liquid number of days that the tank stands idle while its floating roof is landed For a given tank use this information in conjunction with the appropriate standing idle and filling loss equations to determine the emissions for each roof landing episode The annual landing loss emissions can then be determined by summing the emissions from each episode occurring within a given calendar year Emissions from each roof landing episode must be individually determined using accurate temperature data and stored liquid properties for the time of year when the roof landing occurred When using API TR 2567 care must be taken to avoid using certain default parameters that may not accurately reflect a given storage tank For example the daily vapor temperature range should be calculated from the appropriate equation presented within the document instead of the default range being used Similarly care must be taken using the B coefficient from Antoine s equation to calculate the Kg term for certain chemical species The form of Antoine s equation used w
65. ion If the actual vapor pressure is not known gasoline RVP 10 should be selected to determine the emissions TCEQ publication RG 360A 10 m January 2011 A 81 Emissions Inventory Guidelines Additionally for gasoline storage tanks variations in product should be accounted for by using actual vapor pressure information for each month of the year An average gasoline profile should not be used to determine the emissions Speciation If any source specific information about storage tank VOC composition is available use it to speciate the emissions Supply the composition data and any related information such as test results etc with the EI If no source specific information about speciation of storage tank VOCs exists use the default speciation profiles in the current TANKS program For more information on speciation requirements see Chapter 4 Supporting Documentation Include documentation with the EI that supports and validates the emissions reported therein including but possibly not limited to representative samples of e calculations detailing the tank parameters diameter height shell color roof color paint condition shell construction capacity primary and secondary seals fittings and throughput rate if the TANKS program is used a report generated using the detailed report option e physical properties of each product including liquid density liquid molecular weight vapor molecular we
66. ions reduction credits applied implies the use of a monitoring LDAR program Most instrument based LDAR program permit conditions will require the retention of screening value data Since the use of such data in correlation equations provides more accurate emissions determinations the use of average emission factors with applied emissions reduction credits to determine actual annual emissions rates is no longer allowed Reduction Credit for Connector Monitoring Because connector monitoring is not usually required emission reductions are not typically claimed for these components However if a weekly physical inspection program is in place a 30 percent emissions reduction credit applied to average emission factors is allowed To claim credit for any such program the documentation must demonstrate that all elements of the program are in place and were followed If connectors are instrument monitored the correlation equations should be used to determine emissions according to the guidance in this supplement In these cases no additional reduction credit for connector monitoring may be applied to the correlation equation Quantifying Emissions of Odorous or Toxic Inorganic Compounds The best method to determine the emissions of odorous or toxic inorganic compounds like chlorine Cl2 ammonia NH3 hydrogen sulfide H2S hydrogen fluoride HF and hydrogen cyanide HCN would be to develop unit specific correlation equations as describe
67. is intended to help determine and correctly report flare emissions This supplement does not supersede or replace any state or federal law rule or regulation This guidance reflects the current understanding of how flares work how they generate emissions how they are monitored or tested and what data are available for emissions determination This supplement may change over time as a result of findings of scientific studies and as new information becomes available The EAS greatly appreciates any data information or feedback that may improve this supplement The calculation methods represented are intended as an aid alternate methods may be equally acceptable if they are based upon and adequately demonstrate sound engineering assumptions or data If additional guidance is needed regarding the acceptability of a given emissions determination method contact the EAS at 512 239 1773 Introduction This technical supplement offers guidance on identifying quantifying and correctly reporting emissions from elevated flares in the annual EI This document does not address flare structural representation in the inventory For guidance on this topic consult Chapter 3 Definitions In this supplement waste gas refers to gas streams produced in the process unit and routed to the flare for destruction Supplemental fuel refers to the gas that mixes with waste gas prior to its arrival at the flare tip ensuring the combustibility of the
68. issions using the Peng Robinson equation of state option Although other equations of state are available in the model the Peng Robinson equation best suits flash emissions determinations Required inputs may include an extended pressurized condensate analysis as well as other parameters for example temperature pressure and flow for the process being simulated Unlike other flash determination methods process simulators are not constrained by American Petroleum Institute API gravity Process simulators are appropriate for either black oil or gas condensate systems if detailed accurate input data are available E amp P Tank Program API and the Gas Research Institute developed the E amp P Tank model It predicts VOC and HAP emissions flashing working and standing losses TCEQ publication RG 360A 10 m January 2011 A 71 Emissions Inventory Guidelines A 72 from petroleum production field storage tanks The E amp P Tank program bases flash emissions determinations on the Peng Robinson equation of state and requires site specific information to determine emissions rates E amp P Tank is best suited for upstream operations such as stock tanks at wellheads and tank batteries common to several wellheads although it will handle a broad range of API gravities 15 68 The E amp P Tank model allows the user to input compositional analyses from pressurized oil and gas samples to simulate flash generation in storage tanks Specif
69. ithin API TR 2567 and AP 42 Chapter 7 closely resembles the Clausius Clapeyron equation and B values for many chemical species are not readily available in the prescribed units of temperature and pressure In certain cases the Kg term may have to be calculated using the original equation s as presented in AP 42 Chapter 7 Reporting Landing Loss Emissions within the Inventory Landing losses for each storage tank should be reported on the appropriate path within the EL If it is determined that landing loss emissions occurred due to normal routine operation revise annual and ozone season emissions accordingly For specific procedural guidance on reporting emissions in the EI please consult Chapter 4 Determining Emissions from Degassing and Cleaning A 76 Emissions from tank degassing and cleaning operations should be determined using site specific knowledge and material balance equations Alternatively the following methods developed by the EPA can be used to determine emissions TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks Degassing Emptying a Storage Tank For a drain dry fixed roof tank degassing emissions can be determined by a two part process First use the TANKS program to determine emissions from one turnover to identity the vapors displaced during filling Next determine the clingage emissions from one turnover by calculating the emissions as if the tank had
70. k oil This method is not valid for gas condensate systems see Emissions Determination Methodologies Order of Preference above for the appropriate methodologies to determine flash emissions from those sources The method requires eight input variables TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks e stock tank API gravity separator pressure separator temperature e gas specific gravity e volume of produced hydrocarbons e molecular weight of the stock tank gas e the VOC fraction of the tank emissions and e atmospheric pressure The Vasquez Beggs correlation equation determines the dissolved GOR of a hydrocarbon solution as a function of the separator temperature pressure gas specific gravity and liquid API gravity Flash emissions from the VOC storage tank are then determined by multiplying the GOR by the tank throughput the molecular weight of the stock tank gas and the weight fraction of VOC in the gases These equations to determine flash emissions are available in a Microsoft Excel spreadsheet originally developed by the Oklahoma Department of Environmental Quality and can be downloaded at lt www deq state ok us AQDnew resources Calculations 1 1 xls gt Please note that while this spreadsheet indicates an API gravity between 16 and 58 may be used the TCEQ only allows the Vasquez Beggs correlations to be used for black oil systems where the API gravity is le
71. l VOC emission rate from the cooling tower and the measurements of the select VOC species such as HRVOCs should be speciated in the emissions reporting and subtracted from the total VOC emission rate derived from AP 42 Since these methods measure the composition of chemicals in the cooling water rather than the amount of emissions the emissions are not determined by using measured data The appropriate determination methodology will depend upon whether data are gathered by following an approved monitoring and control program plan on file with the TCEQ If so the determination methodology should be reported as B for material balance If not the determination methodology should be reported as E for estimated Please note that in the case of cooling towers such estimates are preferred more than the use of the AP 42 emission factors If the air strippable VOC concentration or cooling water VOC concentration is measured but a large leak occurs between times of sampling events and no monitoring data are available for the period of the leak then use the AP 42 uncontrolled emission factor to determine emissions for the leak period If when the leak began is not known assume that it began immediately after the previous sample was taken If the majority of annual emissions are determined using the measured data the determination methodology should be reported as described in the preceding paragraph Note that the inform
72. l component types refers to those component types traditionally considered and reported as sources of fugitive emissions from piping components valves connectors pumps compressor seals relief valves sampling connections process drains and open ended lines Nontraditional component types refers to component types traditionally not treated as sources of fugitive emissions from piping components but TCEQ publication RG 360A 10 m January 2011 A 29 Emissions Inventory Guidelines identified as such by recent scientific studies Examples include screwed fittings liquid relief valves agitators heat exchanger heads site glasses bolted manways and hatches blind flanges caps and plugs connectors compression fittings and metal to metal seals Expected Emissions The fugitive emissions from piping components may include organic or inorganic compounds in a gaseous or liquid state depending upon the composition of streams flowing through the associated piping components Quantifying Fugitive Emissions from Piping Components Introduction The fugitive emissions from piping components are determined using emission factors or equations statistically developed from component and industry specific sampling data Methodologies will differ depending upon whether a source is monitored using a VOC instrument detector or is not monitored For monitored sources base determinations on correlation equations and the individual screening values
73. lled VOC emission factor No According to AP 42 use of the controlled emission factor 0 7 Ib MMgal is contingent upon the use of applicable control technology to minimize hydrocarbon leaks into the cooling water system and the monitoring of cooling water for hydrocarbons If a monitoring system is sufficient to provide such control then the associated data should be sufficiently detailed to allow for the derivation of an emission rate If the monitoring system is insufficient to provide data for determining emissions then the system is insufficient to provide reliable control and so the uncontrolled VOC emission factor is appropriate Must I report particulate matter emissions Yes While drift eliminators greatly reduce cooling tower drift the drift droplets that do escape are so small and of such little mass that they can remain airborne for some time and travel a significant distance My cooling tower s emission point is currently shown as a fugitive area Must I change this Yes The cooling tower s emission point should be shown as a stack For more information see Cooling Tower Structure earlier in this supplement as well as instructions for completing the Emission Point Information Stack Profile form in 20 0 Emissions Inventory Forms and Instructions TCEQ publication number RG 360B What does the cooling tower characteristic HRVOC Service mean Regardless of the county location
74. loaded e Vessel gas freeing and conditioning emissions will be VOCs with a composition corresponding to that of the previously loaded material or the material now being loaded e Emissions from loading solid bulk material will be particles of the material loaded e Degassing and cleaning emissions will be VOCs with a composition corresponding to that of the material previously held in the vessel compartment e Abrasive blasting results in particulate matter emissions of the abrasive material and the old paint Painting results in emissions of the VOCs that volatilize from the paint as it cures and particulate matter resulting from paint overspray TCEQ publication RG 360A 10 m January 2011 Technical Supplement 5 Marine Facilities Supporting Documentation To allow for the verification of reported emissions include representative sample calculations with the EI submission Supply the data used in these sample calculations including e the amount and type of material processed during each operation including the type and amount of material transferred between vessels at the docks e the date and time of the activity e temperature vapor pressure molecular weight and other factors that affect emission determinations e material composition data if the associated emissions total or speciated depend upon them and e all other information necessary to determine emissions Issues of Special Concern May I omit my mari
75. m vessel compartments prior to change of service maintenance or repair Depending on the vessel compartment s condition as many as three steps in the process may result in emissions degassing deheeling and cleaning Dockside Vessel Emissions explains the emission calculation method for degassing deheeling and cleaning It also references the Air Permits document for determining uncontrolled vessel degassing and cleaning emissions Tank Truck and Rail Car Cleaning Since these techniques use the ideal gas TCEQ publication RG 360A 10 m January 2011 Technical Supplement 5 Marine Facilities law the determination methodology should be reported as S for scientifically calculated If saturation test results are used to calculate degassing deheeling and cleaning emissions the ambient temperature during the test should correspond to or be greater than the average ambient temperature for that year s ozone season Similarly the chemical vapor pressure s used to calculate emissions should be the vapor pressure s of the chemical s at the average ozone season temperature Additionally the test results can only be applied to chemicals that have an equivalent or lower vapor pressure than the tested chemical s vapor pressure If emissions are determined using saturation test results the determination methodology should be reported as B for material balance Submit summary test results with each year s EI and i
76. measure VOCs then the test data should be used to determine emissions code the emissions with a determination methodology of M If the stack test measured total hydrocarbons the VOC emissions should be determined by multiplying the hydrocarbon emission factor by the following ratio AP 42 VOC emission factor AP 42 total organic carbon TOC emission factor The determination methodology should be reported as S Because complex oxidation reactions occur in the combustion chamber that significantly alter the emissions composition it is unacceptable to apply the inlet gas stream s VOC percentage to the stack test TOC emission factor to obtain a VOC emission factor Vendor Data When using vendor data to determine VOC emissions verify that the vendor s emission factor refers to VOCs rather than total hydrocarbons If it does the VOC emissions should be calculated and the determination methodology should be reported as V If the emission factor determines the amount of total hydrocarbons the VOC emissions should be determined by multiplying the hydrocarbon emission factor by the following ratio AP 42 VOC emission factor AP 42 TOC emission factor The determination methodology should be reported as S TCEQ publication RG 360A 10 m January 2011 Technical Supplement 1 Combustion Sources Because complex oxidation reactions occur in the combustion chamber that significantly alter the emissions composition
77. minant code 50001 Note Some vendor provided VOC emission factors exclude formaldehyde In those cases the exclusion should be accounted for in the VOC speciation calculations Subtract the AP 42 formaldehyde factor from the AP 42 VOC emission factor then divide each trace organic factor by the resulting amount EF AP 42 speciated VOC xE E sedition voc 7 EF total VOC AP 42total VOC EF AP 42 formaldehyde Where E speciated voc the tpy rate for a speciated VOC contaminant TCEQ publication RG 360A 10 m January 2011 A 9 Emissions Inventory Guidelines A 10 EF 4p_47 speciated voc the specific trace organic factor for the compound in AP 42 EF 4p_a talvoc the AP 42 VOC emission factor EF 5p 42 formaldehyde the AP 42 formaldehyde factor E oaivoc the tpy total VOC determined using stack test data or vendor data If stack test data or vendor data are used to determine total VOC emissions the determination methodology should be reported as S for scientifically calculated the VOC u emissions should be reported as M or V If an AP 42 emission factor is used to determine the total VOC emissions the determination methodology for all of the VOC pollutants should be reported as A Example Using a vendor supplied VOC emission factor the VOC emissions from a four cycle lean burn compressor have been determined to be 11 2 tons Assuming the composition of the exhaust VOCs is
78. missions for gas condensate systems are in general order of preference e direct measurement of emissions code as M e process simulator models code as S the E amp P TANK program code as O e the gas oil ratio GOR method code as B Note For EI purposes the Environmental Consultants and Research EC R equation is no longer an acceptable method to determine flash emissions for gas condensate systems Direct Measurement of Emissions Direct measurement provides the most accurate results for evaluating flash gas flow rates and the composition of flash emissions however this method can be more costly than the other emissions determination methodologies discussed below Process Simulator Models Process simulators are computer models that use equations of state in conjunction with mass and energy balances to simulate petroleum processes for a variety of engineering purposes Process simulator determinations generally are consistent with laboratory values and therefore are expected to be more accurate when estimating flash emissions than most other determination methods except measurements However process simulators are costly and can be complicated to use There are several different process simulators HYSIM HYSIS WINSIM PROSIM etc each employing similar basic principles While process simulators are primarily used in process design these models can also determine and speciate flash em
79. n this supplement Emission Factors All emission factors discussed in this supplement are available in the PDF document titled Emissions Factors for Equipment Leak Fugitive Components on the EAS s Web page at lt www tceq state tx us goto ieas gt TCEQ publication RG 360A 10 m January 2011 A 31 Emissions Inventory Guidelines Determining Emissions from Monitored Components Quantifying Emissions Using Correlation Equations A 32 Emissions from monitored components must be determined using site specific monitoring data Specifically correlation equations must be used to determine emissions when a permit condition TCEQ rule or commission order requires the retention of screening value data Correlation equations use an instrument measured VOC concentration screening value to determine a component specific emission rate Screening value data are collected using a portable monitoring instrument to sample air from potential leak interfaces on individual pieces of equipment Screening data must be collected in accordance with EPA Reference Method 21 as detailed in 40 CFR 60 Appendix A and Protocol for Equipment Leak Emission Estimates EPA 453 R 95 017 available at the EPA s Web site at lt www epa gov ttnchie1 publications html gt To determine emissions the screening value data are used either in industry specific correlation equations developed by the EPA or in correlation equations developed by a company for a specific p
80. nclude information such as the ambient temperature during testing and vapor pressures of the tested chemicals Abrasive Blasting and Surface Coating Building or repairing marine vessels and offshore platforms may involve abrasive blasting and painting operations Abrasive blasting results in particulate matter emissions of the abrasive material and the old paint Painting results in emissions of the VOCs that volatilize from the paint as it cures and particulate matter resulting from paint overspray Determine these emissions using the Air Permits draft documents Abrasive Blast Cleaning and Surface Coating Operations Since particulate emissions from abrasive blasting are calculated based on the abrasive material usage and the emission factors in the abrasive blast cleaning guidance the determination methodology should be reported as A Since VOC and particulate emissions from coatings are determined based on the coating composition and the application equipment s transfer efficiency the determination methodology should be reported as B for material balance Annual and Ozone Season Emission Rates Determine actual annual emissions following the guidance in this supplement If the same material is handled throughout the year then use annual material throughput and the guidance in this supplement to determine emissions If materials vary determine emissions from each TCEQ publication RG 360A 10 m January 2011 A 61
81. ne season June July and August while zeroing out the throughputs for the other months The resulting emissions will then be distributed throughout the 92 day ozone season Determining Emissions from Flashing Losses Flashing losses occur when a liquid with entrained gases experiences a pressure drop or a temperature increase As the liquid equalizes to a new steady state some of the lighter compounds dissolved in the liquid are released or flashed from the liquid Additionally some of the compounds that are liquids at the initial pressure and temperature transform into a gas or vapor and are released or flashed from the liquid As these gases are released some of the other non flashing compounds in the liquids may become entrained in these gases and will be emitted with them Flashing loss emissions flash emissions are greater as the pressure drop increases and as the amount of lighter hydrocarbons in the liquid increases The temperature of both the liquids and the storage tank will also influence the amount of flash emissions From a process perspective flash emissions from storage tanks generally occur when pressurized liquids are sent to storage at a lower pressure Specifically flash emissions from storage tanks can occur at wellhead sites tank batteries compressor stations gas plants and pigged gas lines when pressurized gas and liquids are sent to atmospheric storage vessels These flash emissions are vented
82. ne emissions from the annual inventory Aren t these emissions included in the area source inventory No The area source inventory only includes emissions from ships in transit Once a ship is docked it is considered a stationary source All non engine emissions from a docked vessel should be reported in the point source inventory Since I don t own the marine vessel why am I required to report its emissions in my inventory Because the marine vessel is at the site supporting the business What if I share a marine loading facility with another company Emissions should be reported by the regulated entity that owns the marine loading facility Please call the EAS for additional guidance about a particular situation Should I report emissions generated when materials are transferred from one marine vessel to another while docked This is sometimes also called lightering or barging Yes All emissions from vessels at the dock should be reported by the dock owner or operator TCEQ publication RG 360A 10 m January 2011 A 63 Emissions Inventory Guidelines References Texas Commission on Environmental Quality 2000 Air Permit Technical Guidance for Chemical Sources Loading Operations TCEQ Air Permits Division draft document 2001 Technical Guidance Package for Agricultural Sources Grain Elevators TCEQ Air Permits Division draft document 2001 Dockside Vessel Emissions TCEQ Air Permits Division draft documen
83. ne stored in the tank and the gas mixture should reflect an increased butane component Next if winter gas blending is carried out at the storage tank additional butane emissions from the blending itself separate from the working and breathing losses from the tank should be estimated and reported in the EI The blending emissions can be determined using a material balance or from engineering knowledge of the blending process Determining Emissions using Chemical Mixtures For compounds whose physical properties can vary widely such as condensate or for site specific or proprietary compounds or chemical mixtures enter specific chemical or mixture data into the TANKS program s chemical database use these new chemical data to generate emissions reports Additionally data on chemical mixtures should be used to determine emissions from tanks where chemicals are combined For example when cutter stock is added to a heavy hydrocarbon storage tank the cutter stock s composition should also be represented in the tank emission calculations by creating a mixture of both components Default Chemical Properties in the TANKS program Care is needed when choosing default chemical properties in the TANKS program For chemicals whose properties can vary widely specific site data should be used For example crude oil storage tanks should account for the actual vapor pressure instead of using the program s default crude oil RVP 5 opt
84. nel at 512 239 1250 Expected Emissions Emissions associated with the dock and the dockside marine vessels except for emissions from marine vessel engines should be determined and reported in the annual EI This includes any emissions from marine vessel to marine vessel transfers i e lightering or barging A marine facility s emissions depend on the activity performed and the materials handled or used Dock emissions may include e fugitive particulate matter from conveying lines and e fugitive VOCs from equipment leak fugitives Dockside marine vessel emissions may include e VOCs from loading or unloading liquid bulk materials e VOCs from loading or unloading liquified gaseous materials e particulate matter from loading or unloading solid bulk materials including lightering or barging at the dock e VOCs from degassing and cleaning liquid vessel compartments and e particulate matter and VOCs from abrasive blasting and surface coating Determining Emissions A 58 For primary guidance on determining marine emissions consult the Air Permits draft guidance document Dockside Vessel Emissions In particular Section 2 of that document addresses each dockside activity discussed in the following section giving background information specific guidance on calculations and references to other specific documents relating to air permits that may also be helpful The following sections address the key points related
85. nent of the waste gas and supplemental fuel e the flare tip diameter and e the steam air assist gas rate Reporting Emissions from a Shared Flare In some cases process streams are sent off site to a flare owned by a different regulated entity The applicable structure including the flare emission point and abatement device should be included in the emissions inventory where the process equipment is located and the emissions are generated However the path emissions will be zero because the owner of the flare is required to report the combustion emissions generated by the flare and the non combusted contaminants A path comment should be included on the path emissions page identifying the shared flare s EPN and its air account number Please call the EAS for additional guidance References Engineering Science preparer 1983 A Report on Flare Efficiency Study Vol 1 Chemical Manufacturers Association Energy and Environmental Research Corporation preparer 1984 Evaluation of the Efficiency of Industrial Flares Test Results EPA report 600 2 84 095 Industrial and Environmental Research Lab U S Environmental Protection Agency 1985 Evaluation of the Efficiency of Industrial Flares Flare Head Design and Gas Composition EPA report 600 2 85 106 Washington A 56 TCEQ publication RG 360A 10 m January 2011 TECHNICAL SUPPLEMENT 5 MARINE FACILITIES Technical Disclaimer This technical supplement is intended to help
86. norganic emissions from flashing landing breathing and working losses Storage A 66 TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks tank emissions may also include emissions from degassing cleaning and defective tank seals and fittings All storage tank emissions whether routine or not should be quantified and reported in the EL Associated Emissions Equipment leaks and loading losses from trucks railcars tank cars etc are two other emissions sources generally associated with liquid storage operations Do not report fugitive emissions from piping components at the same facility emissions point path where storage tank breathing and working loss emissions are reported The fugitive emissions from piping components should be reported at a separate path according to the guidance in Technical Supplement 3 To determine fugitive emissions from piping components consult Technical Supplement 3 Similarly do not report truck railcar tank car etc loading operations associated with storage tanks at the same facility emissions point path where the emissions are reported from storage tank breathing and working losses The emissions from the loading rack and its related emissions should be reported at a unique facility emissions point path For further guidance on structural representation consult Loading Operations in Chapter 3 For guidance on determining emissions from loading
87. ns use the most recent emission factor and report the determination methodology as A Speciation To determine whether or not the VOC emissions from a source need to be speciated consult Chapter 4 Any source specific information about the composition of VOC emissions for a source should be used to speciate the emissions Submit the data and related information with the EI If source specific information about the composition of the VOCs does not exist the VOC emissions should be speciated using the AP 42 factors for the speciated organic compounds formaldehyde toluene and benzene Divide each of these factors by the AP 42 VOC emission factor to obtain the contaminant s speciation ratio Then multiply the source s total VOC emissions by each contaminant s ratio to obtain that contaminant s emission rate The remaining balance of the VOC emissions should be included in the VOC unclassified emissions contaminant code 50001 If stack test data are used to determine total VOC emissions the determination methodology for the speciated emissions should be reported as S for scientifically calculated the VOC u emissions should be reported as M If AP 42 emission factors are used to determine total VOC emissions the determination methodology should be reported as A Example Using stack test data the VOC emissions from a boiler have been determined to be 43 tons No information about the c
88. ns from loading racks at chemical plants and refineries instead use the appropriate SOCMI or refinery emission factors The use of these emission factors must be accompanied by an AVO program performed monthly To claim credit for this program the documentation must demonstrate that all elements of the program are in place and were followed Because the petroleum marketing terminal emission factors include the appropriate reduction credit for the AVO inspection no additional reductions may be taken If a monthly AVO inspection was not performed use the refinery emission factors to determine emissions TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives Quantifying Emissions from Components Exempt from Monitoring Some components may be exempt from monitoring requirements based on size physical location at a facility or low vapor pressure Emissions from exempt components like those from unmonitored components must be calculated and reported Since these components are not monitored calculate their associated emissions based on average emission factors with no reduction credit applied When calculating emission rates inaccessible components and other unmonitored components must be clearly identified and separated from monitored components Quantifying Emissions Using Average Emission Factors with Emissions Reduction Credits Quantifying emissions using average emission factors with emiss
89. nstable flame mode If specific data on destruction efficiency are available for the flare tip and design compounds being combusted gas composition and operating conditions of the flare in question the data may be used to determine emissions in such cases Otherwise it will be necessary to use the destruction efficiency described in the following paragraph Although only limited test data are available for flares operating with an unstable flame EPA test data indicate that destruction efficiencies generally range from 85 to 97 percent in such cases The median destruction efficiency for the EPA data set appears to be approximately 93 percent Although other data suggest that efficiencies may be even lower during unstable flame operations assume a 93 percent destruction efficiency for flare operating conditions that do not satisfy 40 CFR 60 18 For steam assisted flares there is the potential for over steaming the gas stream and the destruction efficiency may be lower than the appropriate destruction efficiencies given in Table A 7 Assume a 93 percent destruction efficiency for flare operating conditions that do not satisfy 40 CFR 60 18 Of course if the flare flame is ever extinguished one should assume no destruction for the period when the flame was out Determining Emissions When flow rate and composition data are available from continuous monitoring systems they should be used to determine the uncombusted emissions Otherwise
90. nt as discussed in Chapter 3 Expected Contaminants The reported emissions should include all of the following TSP contaminant code 0000 e PMyjo contaminant code 20000 TCEQ publication RG 360A 10 m January 2011 A 17 Emissions Inventory Guidelines e PM gt s contaminant code 39999 e VOCs contaminant codes 50001 through 59998 NO contaminant code 70400 SO contaminant code 70510 CO contaminant code 90300 Emissions Determination Methodologies The appropriate emission determination methodologies for air curtain incinerators are in order of preference e V vendor supplied emission factors e A AP 42 factors e S scientifically calculated E estimated If none of these methodologies accurately represents a source s emissions contact the EAS for further assistance A 18 TCEQ publication RG 360A 10 m January 2011 TECHNICAL SUPPLEMENT 2 COOLING TOWERS Technical Disclaimer This technical supplement is intended to help determine and correctly report cooling tower emissions This supplement does not supersede or replace any state or federal law rule or regulation This guidance reflects the current understanding of how cooling towers work how they generate emissions how they are monitored or tested and what data are available for emissions determination This supplement may change over time as a result of findings of scientific studies conducted and as new information becomes av
91. nt code 39999 e VOCs contaminant codes 50001 through 59998 NO contaminant code 70400 SO contaminant code 70510 CO contaminant code 90300 NH contaminant code 70050 Emissions Determination Methodologies A 16 The appropriate emission determination methodologies for combined cycle turbines are in order of preference e D continuous monitoring system F predictive monitoring system M measured stack test data e Q portable analyzer test data e V vendor supplied emission factors e A AP 42 factors e S scientifically calculated E estimated New for this year Portable analyzers have their own determination methodology and should be designated as Q Testing conducted with a portable analyzer does not qualify as stack testing therefore the emissions determination methodology should not be reported as measured M If the stack test results from an identical unit are used to determine the emissions the determination methodology should be reported as estimated E If none of these methodologies accurately represent a source s emissions contact the EAS for further assistance TCEQ publication RG 360A 10 m January 2011 Technical Supplement 1 Combustion Sources NO and CO Emissions NO and CO emissions from these sources are typically continuously monitored If stack test data is used to determine emissions from a combined cycle turbine equipped with
92. nt for ozone season emission calculations The actual short term emissions calculated for the months of June July and August should be used to develop the daily average ozone season emissions If no flow rate or composition data are available engineering estimates should take into consideration annual process variations that might affect flared gas TCEQ publication RG 360A 10 m January 2011 Technical Supplement 4 Flares Speciation of Uncombusted Flared Gas Compounds Depending on the flare service emissions of uncombusted flared gas could include carbon nitrogen and sulfur compounds At this time the composition of the uncombusted flared gas is assumed to remain unchanged Although complex oxidation reactions in the flare flame may alter the emissions composition no definitive method exists to identify those new compounds Thus emission determinations should assume no change in the composition of the uncombusted gas For example consider a flared gas flow rate of 100 pounds per hour of VOC with a composition by weight of e 20 percent toluene e 60 percent xylene and e 20 percent butane If the flare satisfies 40 CFR 60 18 performance criteria with this flow rate and composition then a 98 percent destruction efficiency may be used Based on the flow rate composition and destruction efficiency total VOC emissions would be 2 pounds per hour Since these emissions are assumed to be 20 percent toluene 60 percent xyl
93. ntire period that the roof remained landed Landing losses are inherently episodic in nature and must be determined each time a tank s floating roof is landed Neither the EPA s TANKS program nor any other storage tank emissions software currently determines landing loss emissions as part of routine program operation However landing loss emissions may be determined using the guidance outlined in American Petroleum Institute Technical Report 2567 Evaporative Loss from Storage Tank Floating Roof Landings API TR 2567 EPA has also incorporated this API guidance into a new version of Chapter 7 Organic Liquid Storage Tanks available at lt www epa gov ttn chief ap42 index html gt TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks The emissions determination method detailed in AP 42 Chapter 7 is the preferred method for determining landing loss emissions Floating Roof Tank Designs Tank design considerations will impact both standing idle and filling loss emissions Therefore AP 42 Chapter 7 separates floating roof tanks into the following three categories for emissions determination purposes e internal floating roof tanks IFRTs with a full or partial liquid heel e external floating roof tanks EFRTs with a full or partial liquid heel and IFRTs and EFRTs that drain dry AP 42 Chapter 7 contains standing idle and filling loss equations for each different tank
94. nts that leaked at or above the pegged screening value Count each component once for each period that it leaked at or above the pegged rate For example if a valve monitored quarterly was found to be leaking above the pegged rate each time it should be counted as four pegged valves Monitoring Frequency For each monitored component type enter how frequently the components are monitored annually semiannually quarterly monthly biweekly etc TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives VOC Percentages Enter the average VOC percentages for the gas vapor stream and the light liquid stream Heavy liquid streams are assumed to be 100 percent VOC Monitoring Equipment Data Enter the equipment s calibration value range and the pegged components screening value Emissions Determination Methodology Select the industry type and methodology that were used to determine fugitive emissions Please note that if more than one method is used for a single facility create separate facilities for each factor group used LDAR Program Used Select the leak detection and repair program implemented at the facility Please note that if more than one LDAR program is implemented for a single facility create separate facilities for each such program TCEQ publication RG 360A 10 m January 2011 A 47 TECHNICAL SUPPLEMENT 4 FLARES Technical Disclaimer This technical supplement
95. of the regulated entity if the cooling water cools any process equipment or process fluid stream containing over 5 percent by weight of aggregate highly reactive volatile organic compounds HRVOCs ethylene propylene all isomers of butene and 1 3 butadiene the cooling tower is considered to be in HRVOC service for EI purposes TCEQ publication RG 360A 10 m January 2011 Technical Supplement 2 Cooling Towers If my cooling tower is used exclusively for comfort cooling and does not cool process fluids in a heat exchange system how do I represent that on the EIQ This information may be included in the comments field under the Facility Information portion of the EIQ for the cooling tower in question References Compilation of Air Pollutant Emission Factors 1995 Vol I Stationary Point and Area Sources 5th ed AP 42 Research Triangle Park NC U S Environmental Protection Agency Available online at lt www epa gov ttn chief ap42 index html gt Accessed October 28 2010 Perry Robert H et al 1997 Perry s Chemical Engineers Handbook 7th ed New York McGraw Hill TCEQ publication RG 360A 10 m January 2011 A 27 TECHNICAL SUPPLEMENT 3 FUGITIVE EMISSIONS FROM PIPING COMPONENTS Technical Disclaimer This technical supplement is intended to help determine and correctly report fugitive emissions from piping components This supplement does not supersede or replace any state or federal law rule or regulation
96. omposition of the exhaust VOCs exists Inlet gas analysis was performed but because complex oxidation reactions occur in the combustion chamber that alter the emissions composition significantly the results of the inlet gas analysis cannot be used to speciate the VOC emissions The VOC emission factors in AP 42 should be used to speciate the VOC In AP 42 formaldehyde is one of the compounds that is graded C or better and the emission factor is 0 075 Ib MMscf The total VOC emission factor in AP 42 is 5 5 lb MMscf To obtain formaldehyde s speciation ratio divide the formaldehyde emission factor by the total VOC emission factor TCEQ publication RG 360A 10 m January 2011 Technical Supplement 1 Combustion Sources bss P MMscf MMscf 0 075 0 0136 Multiply the boiler s total VOC emissions by this ratio to determine the formaldehyde emissions 43 tons VOC x 0 0136 0 5864 ton formaldehyde Perform similar calculations for benzene and toluene Report the boiler s VOC emissions as shown in Table A 3 Table A 3 Reporting External Combustion VOC Emissions Contaminant Annual Determination Code Contaminant Emissions Methodology 50001 VOC unclassified 42 3706 tons M 51680 formaldehyde 0 5864 ton S 52420 benzene 0 0164 ton S 52490 toluene 0 0266 ton S Combined Cycle Turbines with Heat Recovery Steam Generators Structure Structural representation of cogeneration turbines with an associated duct burner heat
97. ontaminant Type Net Heating Value Emission Factor NO Steam High Btu 0 0485 Ib MMBtu Low Btu 0 068 Ib MMBtu Air or High Btu 0 138 lb MMBtu Unassisted Low Btu 0 0641 1b MMBtu CO Steam High Btu 0 3503 Ib MMBtu Low Btu 0 3465 Ib MMBtu Air or High Btu 0 2755 Ib MMBtu Unassisted Low Btu 0 5496 Ib MMBtu High Btu gt 1000 Btu scf Low Btu 192 1000 Btu scf TCEQ publication RG 360A 10 m January 2011 A 51 Emissions Inventory Guidelines Regardless of the data s source the determination methodology for NO and CO emissions should be reported as A for TCEQ approved factor For flares subject to the HRVOC regulations in Chapter 115 Subchapter H use the net heating value data required by 30 TAC 115 725 and 115 726 to determine NO and CO emissions for any portions of 2010 during which HRVOC monitors were installed and operational Uncombusted Flared Gas Emissions A 52 Uncombusted flared gas emissions usually include VOCs H2S or both Emissions calculations for these contaminants are based on the flared gas flow rate and composition and the appropriate destruction efficiency which depends upon the actual flare operation Destruction Efficiencies Flare destruction efficiency varies with flame stability operating conditions flare tip size and design the specific compounds being combusted and gas composition The EPA has determined operating limits see 40 CFR 60 18 that result in
98. products The residual product of the coking process is a solid carbon substance called petroleum coke Petroleum coke is removed from the walls of a coke drum by decoking or coke cutting During the decoking or coke cutting process VOC gases trapped in the coke will be released while creating hot spots and steam eruptions Hydrocarbons may also be emitted during the associated cooling and venting of the coke drum prior to decoking Confined Entry Ventilation Confined entry usually occurs during inspection repair or maintenance Before entry gas hazards are controlled by purging inerting flushing or ventilating the space as necessary Examples of confined spaces include but are not limited to tanks manholes boilers furnaces vaults pipes trenches tunnels ducts and bins If the seal of a confined space is broken and uncontrolled the contaminants within the confined space may be released into the atmosphere These emissions should be included in the EI Consult Chapter 3 for information on collective sources to determine if these ventilation emission sources can be grouped in the EI Merox Units A 2 After mercaptan rich hydrocarbon liquids are treated in a Merox unit they are often placed in a storage tank Inert gases may become trapped in this hydrocarbon liquid and can strip VOCs while escaping during storage The EPA TANKS program may not account for these additional emissions in the calculated emissions report I
99. reathing losses are also known as standing losses Cleaning refers to the process of removing vapor sludge or rinsing liquid from a storage tank Degassing is the process of removing organic gases or vapors from a storage tank Equation of state refers to an equation relating the temperature pressure and volume of a system in thermodynamic equilibrium Flash gas refers to the gas or vapor that is generated when a gas or liquid stream experiences a decrease in pressure or an increase in temperature Gas oil ratio GOR means the number of standard cubic meters of gas produced per liter of crude oil or other hydrocarbon liquid Landing losses refers to emissions that occur from floating roof tanks whenever the tank is drained to a level where its roof rests on its deck legs or other supports Pigging and its variants refers to deploying a mobile plug known as a pig through a pipeline to perform various activities such as pipeline cleaning inspection or product removal Working losses are emissions related to the movement of the liquid level in the tank Working losses from fixed roof tanks occur as vapors are displaced from the tank during tank filling and emptying Working losses from floating roof tanks occur as the liquid level and therefore the floating roof is lowered causing the liquid on the exposed tank walls and fittings to evaporate Expected Emissions Storage tank emissions can include VOC HAP toxic and i
100. rking losses flashing losses and landing losses The supplement identifies some of the methods used to quantify those emissions A 4 TCEQ publication RG 360A 10 m January 2011 TECHNICAL SUPPLEMENT 1 SELECTED COMBUSTION SOURCES Technical Disclaimer This technical supplement is intended to help the preparer determine and correctly report emissions from combustion sources This supplement does not supersede or replace any state or federal law rule or regulation This guidance reflects the current understanding of how combustion sources work how emissions are generated how combustion sources are monitored or tested and what data are available for emissions determination This supplement may change over time as a result of findings of scientific studies and as new information becomes available The EAS greatly appreciates any data information or feedback that may improve the supplement The calculation methods represented are intended as an aid alternate methods may be equally acceptable if they are based upon and adequately demonstrate sound engineering assumptions or data For additional guidance regarding the acceptability of a given emissions determination method contact the EAS at 512 239 1773 Introduction This technical supplement addresses common problems and concerns with internal combustion engines turbines reciprocating engines and gasoline and diesel industrial engines external combustion sources burning nat
101. rocess unit The EPA correlation equations are available in Protocol for Equipment Leak Emission Estimates and in the PDF document Emissions Factors for Equipment Leak Fugitive Components on the EAS s Web page at lt www tceq state tx us goto ieas gt The EPA has approved separate correlation equation sets for synthetic organic chemical manufacturing industry SOCMI components and petroleum industry components including refineries marketing terminals and oil and gas production facilities The TCEQ accepts the use of correlation equations for screening values between zero and 100 000 parts per million To determine emissions using correlation equations consider each component s screening value adjusted for the background concentration as follows Before using the screening value in the appropriate correlation equation determine the screened stream s response factor and if necessary adjust the screening value according to the guidance in Protocol for Equipment Leak Emission Estimates For each component with a nonzero and nonpegged screening value enter the screening value into the applicable correlation equation to determine a mass emission rate Sum the individual mass emission rates for each component to determine a total leak rate Note that each individual screening value must be entered into the correlation TCEQ publication RG 360A 10 m January 2011 Technical Supplement 3 Equipment Leak Fugitives equation to pr
102. s from cooling towers Emissions resulting from water additives may be determined based on the additive s chemical characteristics the amount of additive used the volume of cooling water and a scientifically based assumption about the percentage of additive stripped from the cooling water at the tower The determination methodology should be reported as E for estimated Volatile Organic Compounds A 22 Emissions Determination Methodologies Order of Preference The appropriate VOC emissions determination methodologies for cooling towers are in order of preference e emissions data from a HRVOC monitoring system required by 30 TAC 115 764 code as H emissions data from a TCEQ approved air stripping method code as M e emissions data from an approved monitoring and control program plan other than an air stripping method on file with the TCEQ code as B e emissions data from an unapproved monitoring and control program code as E e the AP 42 uncontrolled factor New for this year Emissions based on HRVOC monitoring systems required by 30 TAC 115 764 should be coded as H However emissions determined using monitoring systems not required by 30 TAC 115 764 should be reported as B The use of the AP 42 controlled emission factor is not allowed Detailed explanations of these emissions determination methodologies appear in the following sections Emissions Determina
103. s in the upstream oil and gas industry According to this study many wellhead storage tank batteries meet or exceed emission inventory reporting thresholds The study is available online at lt projects tercairquality org AQR H051C gt This study has identified these types of storage tank batteries as potentially underreported VOC emissions sources Companies that own or operate sites in the upstream oil and gas industry should determine VOC emissions from all wellhead tank batteries to determine if these sites meet the requirements for submitting an EI Each storage tank in the wellhead battery will generate working breathing and flashing emissions Please see Technical Supplement 6 Aboveground Storage Tanks for guidance on determining storage tank emissions The EAS has developed a Material Throughput form specifically for oil field storage tanks and the form should be completed and include the production information for each tank Produced Water Tanks Produced water is generated during oil and gas exploration production transmission and treatment and typically stored on site It may contain various contaminants including hydrocarbons that generate VOC emissions Currently specialized methods for determining emissions from produced water storage tanks do not exist However these tanks are a potential source of VOC emissions that should be represented in the EI If VOCs are present in produced water the VOCs may vaporize in the
104. s is more representative than choosing the annual time basis because it takes into account the monthly variations in meteorological data Due to higher average ambient temperatures during the ozone season the vapor pressure of an organic liquid will increase therefore storage tank emissions rates will be greater in the summer than in the winter Ozone season emissions will need to be determined using the increased vapor pressure data in the appropriate equations Ozone season emissions should be determined by generating a TANKS report for the months of June July and August To obtain the ozone season emissions rate in pounds per day divide the total emissions in pounds for the three month summer period by 92 days the total number of days during the ozone season Obtaining Accurate Emissions Determinations from TANKS Accurate data input is essential to obtaining valid emissions determinations when using the TANKS program The program has default settings for many input variables including floating roof tank fittings and speciation profiles for chemical mixtures Using the default settings can result in inaccurate or invalid emissions determinations Therefore the user should use site specific data to obtain the greatest accuracy Specifically for compounds whose physical properties can vary widely such as condensate mid refined products etc or for site specific or proprietary compounds or chemical mixtures enter specific
105. sist of chlorinated compounds brominated compounds or any other inorganic substance present in the cooling water Volatile Organic Compounds Although some VOC emissions may result from the stripping of organic water treatment chemicals the primary sources of VOC emissions are hydrocarbon containing process fluids leaked into the cooling water by components of the cooling tower heat exchange system Once the hydrocarbon contaminated cooling water reaches the tower the VOCs either flash out of the water or are stripped out by the tower s air flow This may result in many tons of VOC emissions Emissions Determination The process serviced by the cooling tower will largely determine how emissions should be determined and reported For each contaminant type determination methods and special concerns are discussed in the following sections Particulate Matter Some manufacturers provide drift factors that may help determine particulate emissions If a vendor supplied drift factor is used the determination methodology should be reported as V for vendor data If no drift data are available from the manufacturer determine particulate emissions using the appropriate factor from AP 42 Section 13 4 The determination methodology should be reported as A TCEQ publication RG 360A 10 m January 2011 A 21 Emissions Inventory Guidelines Inorganic Compounds Very little research has focused on inorganic compound emission
106. ss than 40 Programs such as GRI s HAPCalc model use the Vasquez Beggs correlation equation to determine flash emissions emissions determinations methods using such programs should be coded accordingly EC R Equation The EC R equation was designed to estimate paraffin VOC emissions in higher proportion than in the default composition The composition of stored condensate liquids deviates substantially from the composition used to derive the equation making it inapplicable for estimating flash emissions Gas Oil Ratio GOR Method The hydrocarbon liquid GOR can be determined by laboratory analysis of a pressurized sample collected upstream of the storage tank from the separator dump line or from a similar apparatus For more information refer to Gas Processors Association Standard 2174 93 It gives details on sampling procedures for collecting a pressurized oil sample The flash emissions are then determined by multiplying the GOR by the throughput of the tank An extended hydrocarbon analysis of the flash gas from the sample should also be conducted to identify the concentrations TCEQ publication RG 360A 10 m January 2011 A 73 Emissions Inventory Guidelines of the individual components of the tank s flash emissions When such sampling is conducted the GOR method is appropriate for either black oil or gas condensate systems Griswold and Ambler GOR Chart Method Please note that obtaining a GOR from sources such as th
107. stable operation of flare flames Therefore emission determinations may vary depending on whether the criteria of 40 CFR 60 18 are satisfied Chapter 115 HRVOC regulations address flare operational requirements in regard to 40 CFR 60 18 For flares subject to HRVOC regulations use the appropriate destruction efficiencies specified in 30 TAC 115 725 Otherwise if the flare s operation is consistent with 40 CFR 60 18 then use the appropriate destruction efficiencies from TCEQ Air Permits guidance shown in Table A 7 Note that for flare operation to be considered consistent with 40 CFR 60 18 it must e meet the flared gas heating value and flare exit tip velocity limitations e be equipped with proper liquid knockout and ignition systems and operate smokelessly Table A 7 TCEQ Air Permits Flare Destruction or Removal Efficiencies for 40 CFR 60 18 Compliant Flares Waste Stream Composition Destruction or Removal Efficiency VOC C C 3 99 VOC gt C3 98 H2S 98 99 reduction should only be applied for compounds containing no more than three carbons that contain no elements other than carbon and hydrogen in addition to the following compounds methanol ethanol propanol ethylene oxide and propylene oxide TCEQ publication RG 360A 10 m January 2011 Technical Supplement 4 Flares If the flare s operation is not consistent with 40 CFR 60 18 then the flare is likely to be operating at or near u
108. t 2001 Technical Guidance Package for Chemical Sources Tank Truck and Rail Car Cleaning TCEQ Air Permits Division draft document 2001 Abrasive Blast Cleaning TCEQ Air Permits Division draft document 2001 Air Permit Technical Guidance for Coating Sources Surface Coating Operations TCEQ Air Permits Division draft document A 64 TCEQ publication RG 360A 10 m January 2011 TECHNICAL SUPPLEMENT 6 ABOVEGROUND LIQUID STORAGE TANKS Technical Disclaimer This technical supplement is intended to help determine and correctly report emissions from aboveground liquid storage tanks This supplement does not supersede or replace any state or federal law rule or regulation This guidance reflects the current understanding of how aboveground liquid storage tanks work how they generate emissions how they are monitored or tested and what data are available for emissions determination This supplement may change over time as a result of findings of scientific studies and as new information becomes available The EAS greatly appreciates any data information or feedback that may improve this supplement The calculation methods represented are intended as an emissions calculation aid alternate calculation methods may be equally acceptable if they are based upon and adequately demonstrate sound engineering assumptions or data For additional guidance regarding the acceptability of a given emissions determination method contac
109. t the EAS at 512 239 1773 Introduction This technical supplement offers guidance on identifying quantifying and correctly reporting aboveground storage tank emissions in the annual EI This document does not address underground storage tanks or devices such as separators reactors mixing vessels or blend tanks For more information on the common tank designs covered in this technical supplement consult the current edition of Chapter 7 of Compilation of Air Pollutant Emission Factors Volume 1 Stationary Point and Area Sources AP 42 This document does not discuss tank structural representation in the El For guidance on this topic consult Chapter 3 Guidance Available in This Supplement This supplement offers guidance on appropriate methodologies for determining emissions from storage tanks EI reporting and special considerations to be made when determining emissions Specifically it addresses expected emissions from aboveground liquid storage tanks TCEQ publication RG 360A 10 m January 2011 A 65 Emissions Inventory Guidelines e quantifying emissions for breathing working flash degassing cleaning and landing losses and e special considerations in determining emissions for certain situations involving storage tanks Definitions In this document breathing losses will refer to the emissions that occur when vapors are expelled from the tank due to changes in temperature barometric pressure or both B
110. tank s headspace causing working and breathing losses To determine working and breathing losses it is possible to add a custom mixture in the TANKS program similar to the composition of the produced water stored in the tanks e g a mixture of 99 percent water and percent condensate to determine the emissions Any VOCs entrained in water produced during oil and gas exploration and production could flash when transferred to atmospheric pressure tanks due to pressure differentials To determine flash losses direct measurement of emissions and measurement of the amount of flash gas from a pressurized TCEQ publication RG 360A 10 m January 2011 Technical Supplement 6 Aboveground Storage Tanks sample of produced water similar to the GOR method are the preferred methods for determining emissions If neither of those methods is available a process simulator may be able to determine emissions provided an accurate sample composition and site specific inputs are available Winter Gas Blending Some sites blend butane into gasoline during the fall and winter to increase the Reid Vapor Pressure RVP of the gasoline in a process called winter gas blending or gas butanizing Butane emissions from this process should be estimated and reported in the EI First the normal working and breathing losses must be adjusted to account for the additional butane present in the gasoline The RVP should be adjusted to match the actual RVP of the gasoli
111. tion Methodologies If cooling water is used to cool VOC process streams emissions will result from process fluid leaks into the cooling water with one exception If the cooling water is maintained at a pressure at least 5 psi greater than the process fluid pressure throughout the entire cooling tower heat exchange system any leak in the heat exchanger will result in water leaking into the process fluid For such systems heat exchanger leaks do not generate VOC emissions from the cooling tower For all other cooling tower heat exchange systems where the cooling water is not maintained at a pressure TCEQ publication RG 360A 10 m January 2011 Technical Supplement 2 Cooling Towers at least 5 psi greater than the process fluid pressure throughout the entire cooling tower heat exchange system use the following guidelines to determine emissions If VOC emissions are determined using an emission factor from Section 5 1 of AP 42 the uncontrolled emission factor 6 Ib MMegal must be used According to AP 42 use of the controlled emission factor 0 7 Ib MMegal is contingent upon the use of applicable control technology to minimize hydrocarbon leaks into the cooling water system and the monitoring of cooling water for hydrocarbons If a monitoring system allows for such control then the associated data should be sufficiently detailed to allow for the derivation of an emission rate either through a measurement of total VOCs or through testing
112. to the EI TCEQ publication RG 360A 10 m January 2011 Technical Supplement 5 Marine Facilities Loading and Unloading Bulk Liquid Materials Loading and unloading bulk liquid materials may result in emissions at the dock and at the vessel Dock emissions result from equipment leak fugitives while vessel emissions result from vapor displacement during liquid loading Determine dock fugitive emissions from piping components following the guidance in Technical Supplement 3 Fugitive Emissions from Piping Components The determination methodology should be reported as A The fugitive emissions should be determined for the entire period when VOCs were present in the dock piping Determine vessel emissions from liquid material loading and unloading using the techniques in the TCEQ air permits draft guide Loading Operations The determination methodology should be reported as A If loading emissions are collected and abated some emissions will escape collection and additionally some collected emissions will escape destruction The Air Permits document Loading Operations gives guidance on determining uncollected emissions and the determination methodology should be reported as A The collected emissions that escape destruction at the abatement device should be determined using an appropriate destruction efficiency The determination methodology should be reported as B During unloading operations vapor in the recei
113. to use this guidance to determine emissions Exceptions for actual operation are identified in the following sections All flare emissions determinations depend upon the flared gas flow rate and composition Therefore before specific emission calculations are discussed the preferred methods for obtaining the actual flared gas flow rate and composition data will be addressed Flared Gas Flow Rate and Composition A 50 To determine the emissions from flares the actual flow rate and the specific composition of the gas routed to the flare must be known The generally preferred methods of obtaining data on flared gas flow rate and composition are in order of preference continuous monitoring with quality assured instruments continuous monitoring with instruments that may not meet all quality assurance tests e periodic testing with instruments and laboratory analytical methods engineering determinations based on detailed process evaluation a one time performance test conducted during the inventory year TCEQ publication RG 360A 10 m January 2011 Technical Supplement 4 Flares For flares subject to Chapter 115 Subchapter H relating to highly reactive volatile organic compounds flow rate and composition data required by 30 TAC 115 725 26 should be used to determine emissions for any portions of 2010 that HRVOC monitors were installed and operational In the absence of monitoring data selection of the most accurate metho
114. total gas stream Flared gas refers to the combination of waste gas and supplemental fuel Pilot gas refers to the gas routed to the flare tip to ensure flared gas ignition Expected Emissions Flare emissions will include at a minimum nitrogen oxides NO carbon monoxide CO and uncombusted flared gas compounds In addition if TCEQ publication RG 360A 10 m January 2011 A 49 Emissions Inventory Guidelines the flared gas contains sulfur bearing compounds emissions will also include hydrogen sulfide H2S and sulfur dioxide SO Products of Combustion Products of combustion include NO CO and SOz Flared and pilot gas heat outputs impact emission rates of NOx and CO The sulfur content of both flared and pilot gases determines SO2 emissions Compounds from Uncombusted Flared Gas The flare s destruction efficiency determines what fraction of the flared gas remains uncombusted The uncombusted flared gas compounds are generally volatile organic compounds but may also include H2S CO ammonia and other organic and inorganic compounds present in the flared gas Emissions Determination Generally flare emissions determinations should be consistent with the TCEQ Air Permits technical guide for flares and vapor oxidizers available at lt www tceq state tx us goto nsr_flares gt However if actual flare operation deviates from the specific operating conditions assumed in permit guidance then it may not be appropriate
115. uality 2004 Calculation of Flashing Losses VOC Emissions from Hydrocarbon Storage Tanks Available online at lt www deq state ok us factsheets air CalculationLosses pdf gt Accessed October 28 2010 U S Environmental Protection Agency 1995 Compilation of Air Pollutant Emission Factors Vol 1 Stationary Point and Area Sources 5th ed AP 42 Research Triangle Park NC EPA Available online at lt www epa gov ttn chief ap42 index html gt Accessed October 28 2010 1999 Preferred and Alternative Methods for Estimating Air Emissions from Oil and Gas Field Production and Processing Operations Emissions Inventory Improvement Program Document Series vol 2 Point Sources ch 10 Washington Available online at lt www epa gov ttn chief eiip techreport volume02 index html gt Accessed October 28 2010 2004 The Natural Gas STAR Partner Update Fall 2004 Washington EPA Natural Gas STAR Program Vasquez Milton and H Dale Beggs 1980 Correlation for Fluid Physical Property Predictions Journal of Petroleum Technology 32 6 784 95 TCEQ publication RG 360A 10 m January 2011 A 83
116. ural gas and combined cycle turbines with heat recovery steam generators For more information about these sources or for information about combustion sources not covered in this supplement consult the appropriate TCEQ new source review guides and the EPA s Compilation of Air Pollutant Emission Factors Volume I Stationary Point and Area Sources publication number AP 42 continually updated Internal Combustion Engines Expected Contaminants Reported engine emissions should include all of the following TSPs contaminant code 70000 PMno contaminant code 20000 e PM25 contaminant code 39999 e VOCs contaminant codes 50001 through 59998 TCEQ publication RG 360A 10 m January 2011 A 5 Emissions Inventory Guidelines HAPs such as formaldehyde gt 0 1 tpy e NOx contaminant code 70400 SO contaminant code 70510 CO contaminant code 90300 Emissions Determination Methodologies The appropriate emissions determination methodologies for internal combustion engines are accepted in the following order of preference D continuous emissions monitoring system or CEMS F predictive emissions monitoring system or PEMS e M measured stack test data e Q portable analyzer test data e V vendor supplied emission factors A AP 42 factors e S scientifically calculated E estimated New for this year Portable analyzers have their own determination methodology and should be designat
117. ving storage tank s vapor space is displaced resulting in emissions that should be reported at the storage tank using storage tank emission calculations and following the general guidance After unloading operations the liquid left in sumps can evaporate over time resulting in emissions Those emissions should be reported with the fugitive emissions from piping components using a material balance approach Loading and Unloading Bulk Liquefied Gaseous Materials Loading and unloading liquefied gases will result in fugitive VOC emissions from dock piping components and may also result in vessel emissions from gas freeing and vessel conditioning When liquefied gaseous materials are transferred to or from a pressurized marine vessel compartment emissions usually come only from dock piping components For guidance on determining these emissions consult Technical Supplement 3 The determination methodology TCEQ publication RG 360A 10 m January 2011 A 59 Emissions Inventory Guidelines should be reported as A Fugitive emissions from piping components should be determined for the entire period when VOCs are present in the dock piping Emissions from a pressurized marine vessel compartment may result from two processes used to ensure safety and product quality gas freeing and gas conditioning Gas freeing is the evacuation of residual liquid heel and vapor after unloading and prior to loading a new material Gas condition
118. y design specifications may eliminate or minimize the fugitive emissions from piping components If components are designed as described in the following sections apply the stated emissions reduction credit Relief Valves 100 percent control may be assumed if either of the following conditions is met e relief valve vents are routed to a properly operating control device or e relief valves are equipped with a rupture disc and pressure sensing device between the valve and the disc to monitor for disc integrity It is important to verify proper relief valve operation if one of these design specifications is not used If a relief valve does not reseat properly the resulting emissions must be determined and reported Possible sources of emissions include storage tanks pressure tanks loading operations reactors and mixing vessels controlled by relief valves Pumps The following pump types are designed to be leakless and are eligible for a 100 percent control credit TCEQ publication RG 360A 10 m January 2011 A 39 Emissions Inventory Guidelines canned pumps magnetic drive pumps e diaphragm type pumps pumps with double mechanical seals that use a barrier fluid at a higher pressure than the process fluid pressure pumps with double mechanical seals that vent the barrier fluid seal pot to a control device Valves Take a 100 percent control credit for the following e bellows valves with bellows welded to both t
Download Pdf Manuals
Related Search
Related Contents
Votre catalogue MANUAL DO UTILIZADOR Anton/Bauer 80750056 Handleiding - Wehkamp.nl Manual de Instrucciones 6918FD - Antonio Prevedello FAQ(ょくある質問) り本製品自体は蓄電できるのですか? 3 Mega-Pixel Vari-Focal IR / Fisheye IP Camera ICA special n0 11 lbw-lf - West Penetone Canada UT60-70P Copyright © All rights reserved.