Home
AN 0B
Contents
1. Otherwise please select this Highlight the Configure Interface line using the down arrow key press Select and configure the following DHCP ON The following parameters will be automatically configured Local IP address for example 192 168 1 22 Gateway IP address for example 192 168 1 1 Network Mask for example 255 255 255 0 DNS Server IP address for example 192 168 1 1 Also set SIP Proxy ON APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU AEQ 2 OTHER POINTS TO CHECK We are now going to quickly overview the rest of configuration menus where it is recommended to check that every parameter is correctly configured Coding Algorithm At the Wizard menu Sel Codec should be G722 for a start although you can change this at a later stage for better quality In order to change the coding algorithm by another pre selected one just select the Sel codec line press Select and select one within the new window shown In order to choose the particular coding modes in each list shown in the Sel codec menu go to Menu gt ADVANCED gt 6 Link profiles gt Select gt Options The audio routing will be most likely correct by default to send Mic 1 audio to the transmission and send the received stream to HP1 headphone output You can however make sure of this from Menu gt ADVANCED gt 3 Audio Settings gt Select Configure the rest of
2. AEQ AEQ PHOENIX AUDIOCODECS APPLICATION NOTE 0 B Connecting AEQ Phoenix Mobile units through Internet via exclusive DSL or cable modem with DHCP router Adapted to Phoenix Mobile user interface The most convenient and reliable way to connect an IP codec to a remote one through Internet is by means of a dedicated exclusive Internet access DSL cable modem as described below No other equipments PC etc are connected to this same access The modem itself usually has an embedded DHCP server that automatically assigns valid IP address mask gateway and DNS server to the IP system s connected to it This application note also describes the recommended procedure when AEQ SIP Proxy is used where both equipments involved in the communication are registered easing the task of finding the remote IP address when it is variable or unknown This document shows the specific steps to make this connection possible in the most general way possible although some verification procedures have been omitted in order to ease the reading and some particular situations may be easier to solve that the presented one For a detailed explanation of every step and for details on how to configure other options that may be more convenient for other cases the reading of the rest of application notes as well as User Manual s chapter 4 is recommended 1 CONNECTING AND CONFIGURING THE EQUIPMENT The physical connection will be done to a LAN port
3. e Connect the network cable to the LAN1 port at the back of the AEQ Phoenix Mobile Connect the other end to the Ethernet port to the router LAN port e Connect at least a microphone and a pair of headphones to the front audio XLR connectors of the Phoenix Mobile e Connect the power supply cable to the AEQ Phoenix Mobile If it is equipped with a battery pack and mains power is not available you can omit this step e Press the ON button at the left side of AEQ Phoenix Mobile Verify that the main display is illuminated e Verify at the back of the unit that the green LED at the right of the Ethernet port starts blinking indicating that the IP connection is active e Configuring the Ethernet port and assignation of Program channel Make sure that we are selecting Program in the main screen the one representing faders and vumeters At the lower center area you should read APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU Program Also by pressing MENU we enter the Wizard menu that should have a PROGRAM legend at the top center area If COORDINATION appears instead in any of both places just press Channel key and channel will be shifted to PROGRAM oe AF ki fessional f gt Cc Broadcast ff Main screen Wizard screen From main screen press Menu to access the Wizard menu Make sure that Select Interface shows IP Ether
4. that the communication has been successfully established and synchronized If the key above HP1 is activated illuminated and the APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CUu AEQ corresponding fader is open the audio received from Phoenix Master should be heard at the headphones Once the connection is OK you can retry as many times as needed varying the selected audio coding scheme in order to get the best possible quality allowed by the network Wizard Menu gt Sel Codec The list of available coding algorithms can be created in Menu gt ADVANCED gt 6 Link Profiles gt Select 5 SENDING A CALL TO ANOTHER PHOENIX OR N ACIP COMPATIBLE CODEC The test call sent to AEQMaster_IP has been automatically answered In order to make a manual call to other codec you must configure the second one the same way as the first unit provided that it is also connected directly to a DHCP modem router If it is not just follow the corresponding Internet access ANOC to ANOF application note Once the reporter equipment connects properly to AEQMaster_IP you can create for convenience new entries in the call book Menu gt ADVANCED gt 2 Contacts with the name and URI of the remote unit the same way it was done for Phoenix Master in the previous chapter and then easily make calls to them You can of course also send the calls without having prev
5. iously created a Call Book entry from the main screen by pressing Menu to go to the Wizard Select the Call to line press Select and URI is selected Then type the desired destination URI in the line below select Enter URI then press OK and type the URI in For this communications mode based on a SIP server you only need to introduce the name of the unit for example Phoenix_123 The call indications optical and also acoustical if enabled will be activated at the destination codec that will either wait for the user to answer the call or automatically off hook if this mode is enabled and then establish the connection The LED next to TX PROG should become green lit and audio should be heard through the headphones The three first screen lines should be Connected lt equipment name gt sip aeq es lt coding scheme gt APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU AEQ For more information and other configuration options please read the User Manual and Application Notes corresponding to other scenarios If you still have doubts please don t hesitate to contact one of our assistance services sat aeq es support aeaqbroadcast com APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU
6. isted in the Call Book and launch the call In order to do so From main screen press Menu Observe the Select contact line If it is Select contact AEQMaster_IP everything is ready and the call is sent only by pressing the green key If the line Select contact presents a different name than AEQMaster_IP at its right just select this line and press select key The call book will be presented Just select AEQMaster IP from the list press OK to close the list and then finally press the green key If the contact was not already created in the Call Book you can create it from the menu Main screen gt Menu gt ADVANCED gt 2 Contacts With the help of the user manual create a new contact with the following parameters Contact AEQMaster_IP Module Type IP URI phoenixMaster sip aeq es when PROXY SIP ON the unit understands that if sip aeqg es is omitted the destination is registered in the same server as this unit Speed Dial n leave it as it was e The top line at the screen displays usually very fast the status of the call and the different phases it goes through Calling Synchronizing and finally Connected e The second line should show AEQMaster_IP e The third line should show G722 or the current audio coding scheme If the remote unit is busy the top line will show Busy 486 e Verify that the LED at the side of TX PROG SYNC key is lit green as an indication
7. parameters after reading the manual according to your particular needs PROXY SIP Configuration You can make sure that this is correct from the main screen Menu gt ADVANCED gt 5 Communications gt 3 SIP config gt 1 Parameters Check that User Name is filled with a user identifier that is previously registered at the AEQ SIP server for example phoenix_123 STUN Protocol 2 Activate ON This is important and recommended as it will ease connecting to other equipment that is behind a router in a local network 3 Server At the moment of writing this document the following STUN server is recommended stun voxgratia org IP 83 103 82 85 If the DNS Server field in the communications menu hasn t been configured you must substitute the STUN name by its IP 4 Port 3478 Press back key in order to go to 3 SIP config gt 2 Proxy and check 1 Activate ON 2 Address sip aeq es APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CU AEQ If the DNS Server field in the communications menu hasn t been configured you must substitute the SIP server name sip aeq es by its IP 82 165 157 20 at the moment of writing this document 3 USER must have the same text value as USER NAME from the former menu followed by sip aeq es for example phoenix_123 sip aeq es 4 Check that a correct password is typed in aeq b
8. y default 5 Check that REALM is sip aeq es 6 Check that DOMAIN is sip aeq es 7 Check that EXPIRES 60 Press back to go to 3 SIP config then select 4 Call Settings and check that Media PORT is 5004 3 REGISTERING AT THE AEQ SIP SERVER If everything is correctly configured after these steps the unit should have registered at the AEQ SIP server and the top line of every screen should display the current time In case it is not registered if the equipment power is cycled the sequence of legends ad the top line should be lt Current time gt Initializing Finding Nat Type Register Error If this happens just double check that the configuration is correct and if necessary ask one of our technical assistance services for support If the unit registers correctly the sequence will be lt Current time gt Initializing Finding Nat Type lt Current time gt 4 SENDING A TEST CALL TO PHOENIX MASTER We are going to go through the correct configuration of the system and prepare it to make a test call to a unit called phoenixMaster sip aeg es that AEQ maintains for our APLICACIONES ELECTRONICAS QUASAR S A TEL 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web WWW aCq CUu AEQ customers and that continuously transmits audio at the public IP address 212 170 163 189 Check that a set of headphones are connected to the front HP1 connection Check that AEQMaster_IP entry is l
Download Pdf Manuals
Related Search
Related Contents
Intelbras SG 800C Britannia Inc. User Manual Osram DoodLED 3 installation of new refrigerant air conditioner USER MANUAL OPTex 07/2005 - Frank`s Hospital Workshop USER MANUAL TBRSF16 User manual - Appliances Online Cables Direct B6LZ-605 networking cable Samsung Gear circle User Manual Copyright © All rights reserved.