1. Glowing green Both supply voltages are on Glowing yellow There is only one supply voltage P1 or P2 on Not glowing Supply voltages P1 and P2 are too low PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 21 FAULT error signal contact red LED Glowing red The signal contact is open i e it is reporting an error Not glowing The signal contact is closed i e it is not reporting an error a Ifthe manual adjustment is active on the FAULT signal contact then the detected error dis play is independent of the setting of the signal contact RM Ring Manager green yellow LED Glowing green RM function active redundant port disabled Glowing yellow RM function active redundant port enabled Not glowing RM function not active Flashing green Incorrect configuration of the HIPER Ring e g the ring is not connected to the ring port Stand by Glowing green Stand by mode enabled Not glowing Stand by mode not enabled RM and Stand by display saving processes of the AutoConfiguration Adapter ACA Flashing alternately Error during saving process LEDs flash synchronously two Loading configuration from the ACA times a second LEDs flash synchronously Saving the configuration in the ACA once a second Port state The green and yellow LEDs at the individual port display port related in formation During the boot phase these LEDs are used
2. EMC emitted interference EN 55022 Class A Yes FCC 47 CFR Part Class A Yes 15 German Lloyd Classification Construction Guidelines VI 7 3 Part 1 Ed 2001 Stability Bi ia Vibration IEC 60068 2 6 Test FC test level according Yes to IEC 61131 2 Germanischer Lloyd Guidelines for the Per formance of Type Tests Part 1 EEEL IEC 870 2 2 table 3 normal installation ac cording to EN 61850 3 Shock IEC 60068 2 27 Test Ea test level according Yes to IEC 61131 2 IEC 870 2 2 table 3 normal installation ac cording to EN 61850 3 Network range TP port Length of a twisted pair segment max 100 m 300 ft Table 4 TP port 10BASE T 100BASE TX PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 27 Wave Fiber System at Expansion Fiber data Product length tenuation code MM 1300 nm 50 125 um 0 8 dB 0 5 km 1 0 dB km 800 MHz km MM 1300 nm 62 5 125 um 0 11 dB 0 4 km 1 0 dB km 500 MHz km SM 1300 nm 9 125 um 0 16 dB 0 30 km 0 4 dB km 3 5 ps nm km Table 5 F O port T00OBASE FX MM Multimode SM Singlemode Power consumption power output Device name Device model Maximum Power output power con sumption Uplink Ports PSSnt SHL 8T 2xTX port 5 3 W 18 1 Btu IT h PSSnet SHL 6T 2F 2xFX port 7 7 W 26 3 Btu IT h Table 6 Power consumption power output PSSnet SHL Scope of delivery Device Scope of delivery PSSn
3. 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode State on delivery autonegotiation activated The socket housing is electrically connected to the front panel PSSnet SHL 20 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland Figure Pin Function 8 1 2 One line pair 7 3 6 One line pair 6 5 E 4 5 7 8 Not used 4 t 3 oo gt r 1 Table 2 Pin assignment of a TP TX interface in MDI X mode RJ45 socket 100 Mbit s F O connection In device variants PSSnet SHL SC these ports are SC connectors 100 MBit s F O ports enable the connection of terminal devices or inde pendent network segments in compliance with the IEEE 802 3 100BASE FX standard These ports support Full or half duplex mode State on delivery full duplex FDX Note Make sure that SM ports are only connected with SM ports and MM ports only with MM ports 2 2 Display elements After the operating voltage is set up the software starts and initializes itself Afterwards the device performs aself test During this process various LEDs light up The process takes around 60 seconds Device state These LEDs provide information about conditions which affect the opera tion of the whole device P O rau Stand by NL RM Figure 9 Device status LEDs P Power green yellow LED
4. EN 60079 0 2006 EN 60079 15 2005 Ex II 3G Ex nA II T3 T4 PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland Housing Warning Never insert sharp objects small screwdrivers wires etc into the inside of the product There is the risk of an electric shock When installing the device make sure the ventilation slots re main free as otherwise damage can occur through overheating Only technicians authorized by Pilz are permitted to open the housing The housing is grounded via the separate ground screw on the bottom left of the front panel i Warning For the ground conductor use a cable with a cross section of at least 1 0 mm The clearance to the ventilation slits of the housing must be at least 10 cm 3 94 in The device must be installed in the vertical position If installed in a living area or office environment the device must be op erated exclusively in switch cabinets with fire protection characteristic sin accordance with EN 60950 1 Environment The device may only be operated at the specified ambient temperature temperature of the ambient air at a distance of up to 5 cm 1 97 in from the device and relative air humidity Install the device in a location where the climatic threshold values specified in the technical data are adhered to Only to be used in an environment with the contamination level speci fied in the technical d
5. also use the switch Web page to switch the signal contact manually and thus control external devices A break in contact is used to report the following conditions via the poten tial free signal contact relay contact closed circuit The detected inoperability of at least one of the two voltage supplies voltage supply 1 or 2 is below the threshold value A continuous malfunction in the device The loss of connection at at least one port The report of the link status can be masked by the Management for each port In the delivery state link status monitoring is deactivated The loss of ring redundancy reserve A detected error during the self test Incorrect configuration of the HIPER Ring MRP or ring coupling The following condition is also reported in RM mode 5 18 Ring redundancy reserve is available On delivery there is no ring re dundancy monitoring Pull the terminal block off the device and connect the power supply and signal lines PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 2 1 6 Installing the device on the DIN rail hub grounding Mounting on the DIN rail The devices are mounted very quickly by snapping them onto the DIN rail Mount the device on a 35 mm DIN rail in accordance with DIN EN 60175 Attach the upper snap in guide of the device into the DIN rail and press it down against the DIN rail until it snaps into place Note The shield
6. courses to technology and products can be found under http www pilz de PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 31 DAT 1 010 05 In many countries we are represented by our subsidiaries and sales partners Please refer to our homepage for further details or contact our headquarters Pilz GmbH amp Co KG Felix Wankel Stra e 2 73760 Ostfildern Germany Telephone 49 711 3409 0 Telefax 49 711 3409 133 E Mail pilz gmbh pilz de gt www www pilz com gt Technical support 49 711 3409 444 22750 EN 01 2010 03 Printed in Germany Pilz GmbH amp Co KG 2010
7. depending on the degree of dan ger posed Danger A Means that death serious physical injury or significant damage to property will occur if the corresponding safety measures are not carried out Warning A Means that death serious physical injury or significant damage to property could occur if the corresponding safety measures are not carried out Caution A Means that minor physical injury or damage to property can oc cur if the required safety measures are not carried out Note Contains important information on the product on how to manage the product or on the respective section of the documentation to which your special attention is being drawn Certified usage Please observe the following The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended or ap proved by the manufacturer The product can only be operated correctly and safely if it is transported stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Supply voltage For safety reasons the devices have been designed to operate at low volt ages Thus they may only be connected to the supply voltage connec tions and to the signal contact with SELV circuits with the voltage restrictions in accordance with IEC EN 60950 1 The supply voltage is electrically isolated from the housing O Use
8. only undamaged parts PSSnet SHL 4 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland Relevant for North America For use in Class 2 circuits The device may only be connected to a supply voltage of class 2 that fulfills the requirements of the National Electrical Code Table 11 b If the voltage is being supplied redundantly two different voltage sourc es the combined supply voltages must fulfill the requirements of the National Electrical Code Table 11 b Relevant for North America For use in Class 2 circuits Only use copper wire conductors of class 1 75 C Relevant for North America for devices certified for hazardous locations Power input and output I O wiring must be in accordance with Class Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accordance with the authority having jurisdiction For devices installed in explosive gas atmospheres according to ATEX RL 94 9 EG only for devices labelled accordingly Relevant for Europe ATEX RL 94 9 EG amp Il 3G Ex nA II T3 T4 refer to the device label Must be mounted in a suitable certified IP 54 housing tested to 4 J impact due to low risk of mechanical danger For ambient temperatures below 10 C and above 60 C use wiring suitable for both the minimum and maximum temperatures Connectors may be connected exclusively in dead voltage state DIP switches may be switched e
9. to display the sta tus of the boot procedure ll Ls pA imal 1 1 45 ts pa peel ho ci Sy a ee 1 1 2 3 Figure 10 Port status LEDs 1 Port status LEDs for isolated or single row RJ45 sockets one green and one yellow LED per port 2 Port status LEDs for double row RJ45 sockets one LED per port glowing flashing either green or yellow 3 Port status LEDs for DSC ST SFP LS link status green LED Not glowing No valid connection Glowing green Valid connection PSSnet SHL 22 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland LS link status green LED Flashing green 1 time a period Port is switched to stand by Flashing green 3 times a peri Port is switched off od DA data yellow LED Not glowing No data reception at corresponding port Flashing yellow Data reception at corresponding port 2 3 Basic set up The IP parameters must be entered when the device is installed for the first time The device provides the following options for configuring IP addresses Configuration via V 24 connection Configuration using the HiDiscovery protocol Configuration via BOOTP Configuration via DHCP Configuration via DHCP Option 82 Configuration using AutoConfiguration Adapter Further information on the basic settings of the device can be found in the Basic Configuration user manual on the CD ROM Default settings IP address The device looks
10. 0BASE SX LX 1 1 1 Combination options for PSSnet SHL The product designation of your device is made from combining the desired product characteristics in accordance with the following table You will find the corresponding short designation in column 3 Item Characteristic Ident Property 1 Product PSS Managed Industrial Ethernet Switch net SHL 2 Number of 10 100 6 4 10 100 Mbit s Ethernet TX Mbit s Ports TX 8 8 10 100 Mbit s Ethernet TX 3 Number of 10 100 2F 2 FX Ports 100 Mbit s Mbit s F O Ports FX 4 F O Ports Type MM Multimode FX 100 Mbit s SM Singlemode FX 100 Mbit s 5 F O Ports Socket SC SC Socket 6 Ring redundancy MRP Media Redundancy Protocol Type Table 1 Combination options of device variants PSSnet SHL PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 1 3 1 1 2 Number of ports and media for PSSnet SHL Figure 1 Device variants with 8 10 100 Mbit s ports PSSnet SHL 6T 2F and PSSnet SHL 8T 1 plug in terminal block 6 pin 2 LED display elements 3 2 pin DIP switch 4 USB interface 5 V 24 connection for external management 6 ports in compliance with 10 100BASE T X RJ45 connections 7 port 1 port 2 Multimode MM or Singlemode SM Fiber optic ports 8 MAC address field 9 IP address field 2 Cr sans OOF 3 7 4 5 9 8 6 Figure 2 Device variants with 8 10 100 Mbit s p
11. U directive s the EU conformity declaration will be at the disposal of the relevant authorities at the follow ing address Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Tel 49 711 3409 0 The product can be used in living areas living area place of business small business and in industrial areas Interference immunity EN 61000 6 2 2005 Emitted interference EN 55022 2006 A1 2007 Class A Warning A This is a class A device This device can cause interference in living areas and in this case the operator may be required to take appropriate measures The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values FCC note Appropriate testing has established that this device fulfills the require ments of a class A digital device in line with part 15 of the FCC regula tions These requirements are designed to provide sufficient protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can radiate same and if it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a liv ing area can also cause interference and in this case the user is obliged to cover the costs of removing the interference Recycling note After usage this product must be disposed of properly as electronic wa
12. ata Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and oper ation of this product and are appropriately qualified for their job This in cludes for example those persons who have been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering trained in providing first aid PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 7 General safety instructions Electricity is used to operate this equipment Comply in every detail with the safety requirements specified in the operating instructions regarding the voltages to apply see page 4 Non observance of these safety instructions can therefore cause material damage and or serious injuries O Only appropriately qualified personnel should work on this device or in its vicinity These personnel must be thoroughly familiar with all the warnings and maintenance procedures in accordance with this oper ating manual LI The proper and safe operation of this device depends on proper han dling during transport proper storage and assembly and conscien tious
13. e a slow blow fuse with a nom inal rating of 6 3 A With AC power supply use a cable cross section of at least 0 75 mm for North America AWG 18 for the current conductor at the voltage input With DC power supply use a cable cross section of at least 1 0 mm for North America AWG 16 for the current conductor at the voltage input Warning A Only connect a supply voltage that corresponds to the type plate of your device PoE power supply unit RPS90 48V LV 18 V DC to 60 V DC PoE power supply unit RPS90 48V HV 48 V DC to 320 V DC or 90 V AC to 265 V AC Shielding ground Note The shielding ground of the connectable twisted pair lines is con nected to the front panel as a conductor O Beware of possible short circuits when connecting a cable section with conductive shielding braiding ATEX RL 94 9 EG O The modules shall be installed in an enclosure in accordance with EN 60079 15 providing a degree of protection of at least IP54 according to EN 60529 taking into account the environmental conditions under which the equipment will be used O When the temperature under rated conditions exceeds 70 C at the ca ble or conduit entry point or 80 C at the branching point of the con ductors the temperature specification of the selected cable shall be in compliance with the actual measured temperature values O Provisions shall be made to prevent the rated voltage from being ex ceeded by transient disturbances of more than 40
14. er source max 5A Overload current protection at input Non replaceable fuse Insulation voltage between operating 800 V DC Protective elements limit the insula voltage connections tion voltage to 90 V DC 1mA and housing FAULT Switching current max 1 A SELV signal contact Environment Switching voltage Storage temperature ambient air Humidity max 60 V DC or max 30 V AC SELV 40 C to 70 C 10 to 95 non condensing Air pressure Up to 2000 m 795 hPa higher alti tudes on request Operating tempera ture 0 C to 60 C Contamination level 2 Protection classes Laser protection Class 1 according to EN 60825 1 2001 Protection class IP 20 EMC and immunity EMC interference immunity IEC EN 61000 4 2 Electrostatic discharge Contact discharge Air discharge 4 kV 8 kV 26 PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland EMC interference immunity IEC EN 61000 4 3 Electromagnetic field 80 2 000 MHz 10 V m IEC EN 61000 4 4 Fast transients burst Power line 2 kV Data line 1 kV IEC EN 61000 4 5 Voltage surges Power line line line 0 5 kV Power line line earth 1 kV Data line 1 kV IEC EN 61000 4 6 Line conducted interference voltages 10 kHz 150 kHz 3V 150 kHz 80 MHz 10V EN 61000 4 9 Impulse shaped magnetic fields
15. et SHL Device Terminal block for supply voltage and signal contact Installation user manual and CD ROM Order numbers Name Order number PSSnet SHL 8T MRP 380 601 PSSnet SHL 6T 2FMMSC MRP 380 602 PSSnet SHI 6T 2FMMSC MRP 380 650 PSSnet SHL 28 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland Accessories Name Order number PSSnet SCA 380 630 Underlying norms and standards Name cUL 508 1998 Safety for Industrial Control Equipment EN 50121 4 2006 Railway applications EMC emitted interference and interference immunity for signal and telecommunication systems EN 55022 2006 A1 2007 IT equipment radio interference characteristics EN 60079 15 Electrical equipment for explosive gas atmospheres part 15 Construction testing and marking of protection type n electrical apparatus EN 61000 6 2 2005 Generic norm immunity in industrial environments EN 61131 2 2003 Programmable logic controllers FCC 47 CFR Part 15 2006 Germanischer Lloyd IEC EN 60950 1 2006 Code of Federal Regulations Ship Applications Classification and Construction Guidelines VI 7 3 Part 1 Ed 2003 Safety for the installation of IT equipment IEC EN 61850 3 Communications networks and systems in stations IEEE 802 1 D Switching GARP GMRP Spanning Tree IEEE 802 1 D 1998 Media access control MAC brid
16. for the IP address using DHCP Password for management Login user password public read only Login admin password private read and write V 24 data rate 9 600 Baud Ring redundancy disabled Ethernet ports link status is not evaluated signal contact Optical 100 Mbit s ports 100 Mbit s full duplex All other ports autonegotiation Ring Manager disabled DIP switch RM and stand by ON Stand by coupling disabled DIP switch RM and stand by ON Port 4 control port port 3 coupling port for red Ring coupling Rapid Spanning Tree enabled USB interface The USB socket has an interface for the local connection of an AutoCon figuration Adapter PSSnet SCA It is used for saving loading the configu ration data and diagnostic information and for loading the software PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 23 Figure Pin Function 1 VCC VBus IN 2 Data N 3 Data 1234 4 Ground GND Table 3 Pin assignment of the USB interface V 24 interface external management The V 24 interface is an RJ11 socket At the V 24 connection a serial interface is provided for the local connec tion of an external management station VT 100 terminal or PC with corre sponding terminal emulation This enables you to set up a connection to the Command Line Interface CLI and to the system monitor VT 100 terminal settings Speed 9 600 Baud Data 8 bit Stopbi
17. g structure HIPER Ring Redundant coupling Link aggregation Redundant power supply Security Protection from unauthorized access Blocking of unauthorized messages MAC or IP based Synchronized system time in the network Network load control Operation diagnosis Diagnostics hardware self testing Reset Priority VLAN Topology Discovery Web based Interface Command Line Interface CLI SNMP 802 1x port authentication Real Time Clock 1 1 Description of the device variants The devices differ with regard to the range of software functions the number of interfaces and the media type for connecting segments The table below shows three port categories for each product variant uplink ports and other ports The table also shows for each product category the number of ports you can select and the type of ports In the column for the port type the abbreviations F O optical fiber and TP twisted pair indicate the media type while the abbreviations SC and RJ45 indicate the socket type PSSnet SHL 12 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland Typ Number of TP Ports Number of F O Ports Type Socket Socket PSSnet SHL 8T MRP 8 RJ 45 PSSnet SHL 6T 1FMMSC MRP 6 RJ 45 2 Multimode SC PSSnet SHL 6T 1FSMSC MRP 6 RJ 45 2 Singlemode SC The devices comply with the specifications of the standard s ISO IEC 8802 03 10BASE T 100BASE TX 1000BASE T ISO IEC 8802 03 100BASE FX ISO IEC 8802 03 100
18. ges includes IEEE 802 1p Prior ity and Dynamic Multicast Filtering GARP GMRP IEEE 802 1 Q Tagging IEEE 802 1 Q 1998 Virtual Bridged Local Area Networks VLAN Tagging GVRP IEEE 802 1 w 2001 Rapid Reconfiguration IEEE 802 3 2002 Ethernet IEEE 1613 Standard Environment and Testing Requirements for Communica tion Networking Devices in Electric Power Substations ISA 12 12 01 cUL 1604 CSA C22 2 No 213 Electrical Equipment for Use in Class and Class Il Div 2 and Class Ill Hazardous Classified Locations Table 7 List of norms and standards Certified devices are marked with a certification indicator From the imprint on the device label you will see the current certification status of your device PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 29 Certifications Standard cUL 508 CSA C22 2 No 142 Yes ISA 12 12 01 CSA C22 2 No 213 Yes German Lloyd ATEX RL 94 9 EG Table 8 Certifications PSSnet SHL 30 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland A Further support Technical questions and training courses In the event of technical queries please contact your local Pilz distributor or Pilz office You can find the addresses of our distributors on the Internet www pilz de Our support line is also at your disposal Tel 49 711 3409 0 Fax 49 711 3409 133 The current training
19. ing ground of the connectable twisted pair lines is con nected to the front panel as a conductor UA MAY Figure 7 Mounting on the DIN rail Grounding With the PSSnet SHL the front panel of the device is grounded via the separate ground screw For the ground conductor use a cable with a cross section of at least 1 0 mm 2 1 7 Dimension drawings Dimension drawings for PSSnet SHL PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 1 9 Figure 8 Dimensions of device variants with 8 ports 2 1 8 Installing the terminal block start up procedure O Mount the terminal block for the voltage supply and signal contact on the front of the device using the snap lock Make sure that the snap lock snaps into place By connecting thevoltage supply via the terminal block you start the opera tion of the device 2 1 9 Connecting the data lines You can connect terminal devices and other segments at the ports of the de vice via twisted pair cables or F O cables O Install the data lines according to your requirements 10 100 Mbit stwisted pair connection These connections are RJ45 sockets 10 100 Mbit s TP ports enable the connection of terminal devices or inde pendent network segments according to the IEEE 802 3 10BASE T 100BASE TX standard These ports support Autonegotiation Autopolarity Autocrossing if autonegotiation is activated
20. operation and maintenance procedures Never start operation with damaged components Only use the devices in accordance with this manual In particular ob serve all warnings and safety related information O Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose OO Note LED or LASER components in compliance with IEC 60825 1 2001 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Warning Laser light Do not look into the beam or view it directly with optical in struments e g magnifying glasses microscopes Failure to observe this warning within a distance of 100 mm can endanger your sight Light is emitted from the optical connections or from the ends of the opti cal fibers that are connected to them Light Emitting Diode CLASS 2M wave length 650 nm power lt 2 mW according to DIN EN 60825 1 2003 10 National and international safety regulations O Make sure that the electrical installation meets local or nationally applicable safety regulations Note on the CE marking The devices comply with the regulations contained in the following Euro pean directive s PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 2004 108 EG Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility In accordance with the above named E
21. orts 1 to 9 see fig 1 PSSnet SHL 14 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 2 Assembly and start up The devices have been developed for practical application in a harsh indus trial environment The installation process is correspondingly simple On delivery the device is ready for operation The following thematic sequence has proven itself in practice Unpacking and checking Installing the SFP modules optional Insert data in label area Adjust DIP switch settings Connect PoE power unit optional Connect the terminal block for voltage supply and signal contact and connect the supply voltage Install the device on the DIN rail hub grounding Install the terminal block start up procedure Connecting the data lines 2 1 Installing the device 2 1 1 Unpacking and checking O O Check whether the contents of the package are complete see Scope of delivery Check the individual parts for transport damage PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 1 5 2 1 2 Installing the SFP modules optional Figure 3 1 Fast EHTERNET fiber optic SFP module 2 Gigabit ETHERNET fiber optic SFP module 5 Before attaching anSFP module first remove the protective cap over the socket O Push the SFP module with the lock closed into the socket until it latches audibly in place Note Only use Pilz SFP modules see Scope of deli
22. pilz more than automation safe automation Industrial Ethernet Switches PSSnet S All rights to this documentation are reserved by Pilz GmbH amp Co KG Copies may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH amp Co KG in some countries Content Content Safety instructions About this manual u Key 1 Device description 1 1 Description of the device variants 1 1 1 Combination options for PSSnet SHL 1 1 2 Number of ports and media for PSSnet SHL Assembly and start up 2 1 Installing the device 2 1 1 Unpacking and checking 2 1 2 Installing the SFP modules optional 2 1 3 Insert data in label area 2 1 4 Adjust DIP switch settings 2 1 5 Supply voltage and signal contact 17 2 1 6 Installing the device on the DIN rail hub grounding 2 1 7 Dimension drawings 2 1 8 Installing the terminal block start up procedure 2 1 9 Connecting the data lines 2 2 Display elements 2 3 Basic set up 2 4 Disassembly 3 Technical data A Further support PSSnet SHL Safety instructions Notes on safety This manual contains instructions to be observed for ensuring your per sonal safety and for preventing damage The warnings appear next to a warning triangle with a different heading
23. ste in accordance with the current disposal regulations of your county state country PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 9 About this manual The following manuals are included as PDF files on the enclosed CD ROM User manual Installation User manual Basic configuration User manual Redundancy configuration Reference manual Web based Interface and Reference manual Command Line Interface The Network Management Software HiVision Industrial HiVision provides you with additional options for smooth configuration and monitoring Configuration of multiple devices simultaneously Graphical interface with network layouts Auto topology discovery Event log Event handling Client Server structure Browser interface ActiveX control for SCADA integration SNMP OPC gateway Key The commendations used in this manual have the following meanings Listing Work step Subheading 10 PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 1 Device description The PSSnet SHL family provides you with a range of Switch variants You can set up your device individually based on different criteria Number of ports Media type Types of connectors The PSSnet SHL devices are designed for the special requirements of indus trial automation They meet the relevant industry standards provide ver
24. t 1 bit Handshake off Parity none The socket housing is electrically connected to the front panel of the de vice The V 24 interface is not electrically isolated from the supply voltage RJ11 DB9 5 5 CTS 1 6 o2 ne 2 2 0078 IX 3 3 i o GND 4 lt o2 1 RX 5 5 RTS 6 Figure 11 Pin assignment of the V 24 interface and wiring to the DB9 connector You will find a description of the V 24 interface in the Basic Configuration User Manual on the CD ROM PSSnet SHL 24 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 2 4 Disassembly E Removing the device from the DIN rail To take the device off the DIN rail insert a screwdriver horizontally un der the housing into the locking slide pull it without tipping the screw driver downwards and lift the device upwards MN INN N MAY QO PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 25 3 Technical data General technical data Dimensions PSSnet SHL 6T 74 mm x 131 mm x 111 mm WxHxD PSSnet SHL 8T Weight PSSnet SHL 6T 410g PSSnet SHL 8T Power supply Operating volta Rated voltage range DC 12 to 48 VDC Max voltage range DC min 9 6 to max 60 V DC Rated voltage range AC 24 V AC Max voltage range AC min 18 to max 30 V AC Safety extra low voltage SELV re dundant inputs disconnected Relevant for North America Nec Class 2 pow
25. type plate of your device Make sure that the contact load capability of the signal contact is not exceeded see on page 50 Technical data Supply voltage The supply voltage can be connected redundantly Both inputs are uncou pled There is no distributed load With redundant supply the power sup ply unit supplies the device alone with the higher output voltage The supply voltage is electrically isolated from the housing See Insulation voltage in chapter Technical data on page 50 You can choose between DC or AC voltage when connecting the supply voltage You use the 24V and OV pins to connect the AC voltage see fig 16 PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 1 7 La zu EZ al FAULT A FAULT A ge ze 1 1 2 2 Figure 6 Connecting the supply voltage at the 6 pin terminal block 1 DC voltage voltage range 9 6 V DC to 60 V DC 2 AC voltage voltage range 18 V AC to 30 VAC Note With non redundant supply of the main voltage the device reports a loss of power You can avert this message by applying the supply volt age via both inputs or by changing the configuration in the Management Signal contact The signal contact FAULT for pin assignment of terminal block see fig 16 monitors the functioning of the device thus enabling remote di agnostics You can specify the type of function monitoring in the Man agement You can
26. very 2 1 3 Insert data in label area The information field for the IP address on the front of the device helps you to structure your network installation clearly rau rk RS20 ap 0 12402 p FAULT 18 DA stana jee oe RM RM Stand b et Figure 4 Label area for IP address of device 1 IP address of device label area 2 MAC address of device label PSSnet SHL 16 Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 2 1 4 Adjust DIP switch settings The 2 pin DIP switch on the front panel of the device gives you the following options Stand byl al Figure 5 2 pin DIP switch Switch Switch Ring Coup Ring Cou Ring Control Cou Software con RM stand by redun ling Manag pling port port pling figuration position position dancy switch er Manag port er OFF OFF on on off off 1 2 ON OFF on on on off 1 2 OFF ON on on off on 1 2 3 4 ON ON SW config has priority over DIP switch configuration State on delivery both DIP switches ON O Before starting operation of the device check whether the default settings of the DIP switch correspond to your requirements 2 1 5 Supply voltage and signal contact The supply voltage and the signal contact are connected via a 6 pin terminal block with a snap lock Caution A Note the safety instructions see on page 4 Notes on safety and only connect a supply voltage that corresponds to the
27. xclusively in dead voltage state The device does not contain any service components Internal fuses are only triggered if there is a fault in the device If the device is not functioning correctly or if it is damaged switch off the voltage supply and return the device to the plant for inspection Only switch on the supply voltage to the device if the housing is closed the terminal blocks are wired up correctly and the terminal blocks are connected Supply voltage for PoE power supply units optional Connect the protective conductor with the ground screw before you set up the other connections When removing the connections you re move the protective conductor last Make sure that the cross section of the protective conductor cable is the same size as or bigger than the cross section of the voltage supply cables Only use connection cables that are permitted for the specified tem perature range PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 5 Warning A If the neutral conductor or the negative terminal of the supply voltage is not grounded If you are using a DC voltage greater than 125 V DC for the sup ply voltage install a suitable input fuse For RPS90 48V LV power supply units use a slow blow fuse with a nom inal rating of 10 A for the voltage supply input For RPS90 48V HV power supply units us
28. y high operational reliability even under extreme conditions and also long term reliability and flexibility The devices allow you to set up switched industrial ETHERNET networks that conform to the IEEE 802 3 and 802 3u standards using copper wires or optical fibers in a line or ring structure The devices work without a fan The voltage is supplied redundantly Mount the devices by simply snapping them onto a DIN rail mounting them on a wall only RS22 RS32 Depending on the device variant you can choose various media to connect terminal devices and other infrastructure components twisted pair cable multimode F O singlemode F O The twisted pair ports support Autocrossing Autonegotiation Autopolarity There are a number of convenient options for managing the device Admin ister your devices via a Web browser Telnet management software e g HiVision a V 24 interface locally on the Switch The HIPER Ring MRP redundancy concept enables a quick reconfigura tion With one additional connection projection remains simple Product configuration data can be provided by diagnosis displays displaying the operating parameters a label area for the IP address PSSnet SHL Pilz GmbH amp Co KG Felix Wankel Str 2 73760 Ostfildern Deutschland 1 1 Depending on the software you choose the devices provide you with a large range of functions Redundancy functions Rapid Spanning Tree Protocol RSTP Redundant rin