1. Table 3 Example of ST4 delay settings ST4 Switch Settings ST4 Time Delays 1 2 3 4 5 6 7 X FiST Modes of Triggering The X FiST operates in four different modes for triggering pyrotechnics e G SWITCH CLOSE GS C This mode begins timing once the G SWITCH has closed for a minimum of 0 5s The G SWITCH closes at 2 1G s 10 of acceleration e G SWITCH OPEN GS O This mode begins timing once the G SWITCH has opened slowed down for a minimum of 0 5s The G SWITCH closes at 2 1G s 10 of acceleration opens at less then that e PULL PIN OPEN PP O This mode begins timing once the PULL PIN port connection is open for a minimum of 0 5s also called a BREAK WIRE system e PULL PIN OPEN and G SWITCH CLOSE PP O amp GS C This mode begins timing once the PULL PIN port connection is open for a minimum of 0 5s also called a BREAK WIRE system as well as the G SWITCH has been closed for at least 0 5s Battery Connections The X FiST was designed to operate using 9V batteries We here at XAVIEN recommend using a switch to insure ease of use when powering the unit up and down The X FiST has an AUX AUXILLARY input that allows the user to connect a secondary power source The AUX input is ONLY used when you want to have more current sourcing for your pyrotechnics this port is NOT intended to be used to power the X FiST b
2. xavier X FiST XAVIEN Five Stage Timer User Manual and Instructions ie FIST WWW Xm Nor a Rev aa JJa XAVIEN PO Box 7433 Goodyear Az 85338 www xavien com System Overview The X FiST is a five 5 stage G SWITCH PULL PIN activated sequential timing and control system The X FiST was designed to meet the needs of multi staged rockets some of these include air starting of clusters and parallel boosters as well as advanced multi staged rockets Time and mode settings are set using multiple DIP switches that allow programming of each stage It runs off of an external DC power supply ranging from 7V to 15V with the option of an AUX AUXILLARY input for connecting a secondary DC power source to increase output to pyrotechnics Both the MAIN and AUX power inputs are reverse battery protected with LED indicator to show reverse connection The X FIST has a total of five 5 stages that can be configured in various ways Stages 1 2 and 3 can be triggered in four different ways G SWITCH CLOSE G SWITCH OPEN PULL PIN OPEN and finally G SWITCH CLOSE and PULL PIN OPEN Stage 4 can be configured as either G SWITCH OPEN or G SWITCH CLOSE The air start stage is designed to activate on G SWITCH CLOSE this is NOT configurable The AIR START stage is designed to allow people to air start a cluster of motors
3. this equipment are beyond our control the purchaser or user agrees to hold XAVIEN and their agents from any and all legal claims demands actions debts liabilities judgments costs and attorney fees arising out of claimed on account of or in any manner predicted upon loss or damage to property of or injuries to or death of any and all persons arising out of the use of this equipment Due to the nature of electronic devices the application and environments for these devices the possibility of failure can never be completely ruled out It is the responsibility of the purchaser or user of this equipment to properly test and simulate the actual conditions under which the device is intended to be used to ensure the highest degree of reliability safety and success I Product Warranty The X FiST has a warranty of 1 year starting from date of purchase as long as all the guidelines have been followed that are outlined is this document Any improper use or carelessness on the part of user will void the warranty If your unit has problems send an email to RMA XAVIEN COM Once this has been done XAVIEN will send you a return material authorization RMA number that you need to include with your unit DO NOT send any units back to XAVIEN without this RMA number if we receive product with no RMA it will NOT be accepted and mailed back unrepaired Revision History PCB REV 1 00A DATE 05 30 2006 FW REV 1 00A DATE 05 30 2006 DOC
4. MPORTANT Switches MUST be set prior to turning power on to X FIST The microcontrollers ONLY read the switch settings on power up If changes need to be made turn unit OFF set switches and cycle power back ON The G SWITCH used by the X FiST closes at 2 1G 10 please keep this in mind for SLOW launches If your rocket will have less then 2 1G s 10 of acceleration please configure your system for PULL PIN operation Unit MUST be powered OFF when installing pyrotechnics to the X FiST ONLY turn power on AFTER the X FiST has been installed the rocket is setup on the launch pad and you are ready to launch the rocket NEVER transport your rocket with an X FiST that is installed and powered up Not following these precautions can cause damage and a potential injury safety is critical AIR START Configuration and Operation The AIR START stage begins countdown after the G SWITCH has closed Figure 2 shows the DIP switch and the associated values of each switch To activate a switch you move it to the upper position towards the ON silk screened on the DIP switch Figure 2 AIR START stage DIP Switch with all switches in the OFF position Switch Value Table 1 gives examples of a few of the DIP switch settings for the AIR START stage For example to get a delay of 3 0 seconds you would turn ON switch 2 and switch 3 1 second 2 seconds 3
5. REV 1 01A DATE 05 30 2006 10
6. able 2 gives examples of a few settings For example to get a delay of 10 seconds in GS C you would turn ON switch 4 and switch 6 2 seconds 8 seconds 10 seconds the rest would be OFF Table 2 Example of ST1 ST2 and ST3 delay settings ST1 ST2 ST3 Switch Settings ST1 ST2 ST3 Time Delays 1 2 3 4 5 6 7 ST4 Configuration and Operation ST4 can be programmed using the M A switch to activate in two different modes G SWITCH CLOSE or G SWITCH OPEN Figure 6 shows the DIP switch and the associated values of each switch To activate a switch you move it to the upper position towards the ON silk screened on the DIP switch Figure 6 ST4 DIP Switch with all switches in the OFF position fofa s 1 2 3 4567 Switch Value O o Stage 4 can be independenily configured for two modes of triggering using the M A switch Figure 7 explains each switches meaning and gives 2 examples of configuration Figure 7 TRIGGERING MODES for ST1 ST2 and ST3 TRIGGER MODE SWITCH SETTINGS G SWITCH CLOSE GS C M A OFF M B OFF G SWITCH OPEN GS O M A ON M B OFF MODE GS C MODE GS 0 DELAY 37s DELAY 14s ON FHT Kr x H Di 1s 2s i i the iit As Ce dots Table 3 gives examples of a few settings For example to get a delay of 18 seconds in GS O mode you would turn ON switch 1 3 and switch 6 1 second 16 seconds 17 seconds the rest would be OFF
7. as part of their staging Each stage has a red LED indicator to show continuity of pyrotechnic the LED is ON when the X FiST senses continuity Specifications Battery MAIN external 7 15 VDC Battery AUX external 7 15 VDC PEAK Firing Current 25A 3sec PEAK Firing Current 50A 10m sec PEAK Firing Current 90A 1m sec Dimensions 1 95 Wx48 L Weight without battery 40 0 grams Delay Settings ST1 1 second to 31 seconds in 1 sec increments Delay Settings ST2 1 second to 31 seconds in 1 sec increments Delay Settings ST3 1 second to 31 seconds in 1 sec increments Delay Settings ST4 1 second to 63 seconds in 1 sec increments Delay Settings AIR ST 0 5 seconds to 7 5 seconds in 0 5 sec increments MIN Battery Load All switches OFF All outputs OFF 40mA MAX Battery Load All switches ON All outputs OFF 75mA Operational Overview Figure 1 depicts the layout of the X FiST Figure 1 X FiST Assembly STAGE 3 STAGE 1 STAGE 2 SWITCHES SWITCHES SWITCHES STAGE 2 STAGE 1 ji T T CONTINUITY CONTINUITY SE OG LED LED a MAIN INPUT OUTPUT hh Ma OUTPUT n gg te 14 E sm KR Rl n we UT STAGE 3 E a II UR ar Im mE l MAR OI I aa AUX INPUT OUTPUT de REV AUX INPUT PORT AIR START C OUTPUT STAGE 3 AIR START EN EE a se CONTINUITY SWITCHES eae STAGE 4 LED STAGE 4 CONTINUITY SWITCHES L I
8. ery important the arrow must be pointing in the direction of travel The mounting holes are 0 125 this allows various size screws to be used Just verify the clearance of both the screw and the head to insure a proper fit without damaging the unit ma j STAGE 3 puen closes oe Bo oa min arm Ot ae Beecocs Bees MT o STATUS mm m a i ra a TT mimmin www xavien com ym slalaa ooo oe opm v t BEER BOB 05 SG Ss Go PULL PIN Atte Beoseseeces AIR START STAGE 4 URGENT The X FiST MUST be protected from ejection charge and motor residue These are corrosive and over time can damage the X FIST It is good practice to clean the unit using Isopropyl Alcohol 70 alcohol or better after the unit has been used ARROW on PCB MUST be pointed in direction of travel Handling Precautions These units are sensitive to damage from ESD and should always be handled in a properly grounded environment damage from ESD is not covered under the warranty Never transport or handle a rocket with an X FIST that is powered up and connected to live pyrotechnic charges When installing electric matches to an X FiST make sure unit is powered off Before launching verify that the red CONTINUITY LED is on for each output stage that has a pyro installed I Product Disclaimer and Limit of Liability Since the use and application of
9. n power on verify green POWER LED is on If red RVS POLARITY LED is on turn power off and reverse power leads Repeat step 1 Turn DC INPUT port off Connect power source to AUX port if being used turn power on if red RVS POLARITY LED is on turn power off and reverse power leads Repeat step 3 Turn AUX port off Make sure unit is NOT powered up if it is turn it OFF Set DIP switches to desired time delay Verify PULL PIN is connected as desired NOTE if PULL PIN is chosen and the unit senses it open at POWER UP the unit goes into a PULL PIN lockout mode and blinks the blue STATUS LED Turn off power connect the PULL PIN line and repeat step 7 Install igniter electric match making sure screw terminals are not loose hand tighten only Turn POWER on to the X FiST verify that the green POWER LED and the red CONTINUITY LED s are ON If the red continuity LEDs are OFF you have a continuity issue with your pyro if the green LED is OFF you have a power problem If all 6 LED s are on green POWER and 5 red CONTINUITY unit is ready for launch NOTE you will ONLY see the continuity light on if a pyrotechnic is installed at that channel Mounting Installation The X FiST must be installed securely to prevent the unit from being damaged during use Since this unit does depend on a G SWITCH orientation of the unit is v
10. seconds the rest would be OFF Figure 3 gives you switch examples for a delay of 7 0 seconds and 4 5 seconds Table 1 Examples of AIR START delay settings AIR START Switch Settings AIR START Time Delay 1 2 3 4 0 5 seconds Figure 3 Example switch settings DELAY 7 0s DELAY 4 5s ST1 35 ST2 and ST3 Confi uration and O eration ST1 ST2 and ST3 can be programmed using the M A and M B switches to activate in four different modes G SWITCH CLOSE G SWITCH OPEN PULL PIN OPEN and G SWITCH CLOSE and PULL PIN OPEN Figure 4 shows the DIP switch and the associated values of each switch To activate a switch you move it to the upper position towards the ON silk screened on the DIP switch Figure 4 ST1 ST2 and ST3 DIP Switches with all switches in the OFF position sJefefefefefe 123 45 6 7 Switch Value MA 2 a ae Stages 1 2 and 3 can be independently configured for four modes of triggering using the M A and M B switches Figure 5 explains each switches meaning and gives 2 examples of configuration Figure 5 TRIGGERING MODES for ST1 ST2 and ST3 TRIGGER MODE SWITCH SETTINGS G SWITCH CLOSE GS C M A OFF M B OFF G SWITCH OPEN GS O M A ON M B OFF PULL PIN OPEN i PP O M A OFF M B ON PULL PIN OPEN amp G SWITCH SEOSE PP O GS C M A ON M B ON MODE PP O MODE GS C DELAY 19s DELAY 3s T
11. y itself If using the AUX port make sure you are also using the DC INPUT port as well The voltage ratings at both the AUX and DC INPUT ports are minimum of 7V with a maximum of 15V DC We have equipped the unit with a small green power indicator so the user can easily identify when the unit has power applied this only applies for the DC INPUT port It is recommended to always ground test your setup to verification purposes This will help to insure that the X FiST and your configuration will work to your expectations It is always a good idea to insure you have a fresh new battery before any launches occur Both the AUX and DC INPUT ports ARE reverse polarity battery protected with red LEDs to indicate reverse polarity Pyrotechnic Installation The X FiST has been tested using various igniters and electric matches To install a pyrotechnic device onto the X FiST power needs to be OFF you simply unscrew the output terminals The terminals are screw based terminal blocks for easy access and reliability User does not need to worry about which terminal goes to which leg of the igniter electric match Make sure you hand tighten ONLY too much torque can damage the unit screw terminals after igniter electric match has been installed Setup Sequence This is the recommended sequence for setting up the X FiST 1 oy oo Connect power source to DC INPUT port tur
Download Pdf Manuals
Related Search
Related Contents
Designers Choice Collection AC18152-SN Installation Guide universidade tecnológica federal do paraná campus pato Linha Romi E - Platina Máquinas feud`atterrissage.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. marche Bedienungsanleitung Operating Instructions Welcome to the heart of this website. The manual infos are updated en user instructions and safety - N USER`S MANUAL Copyright © All rights reserved.