Home

LM User Manual

image

Contents

1. This unit is equipped with 3 weight unit modes i e kg lb and lb oz Default weight unit kg without pound units Follow the below step to employ disable the pound weight unit a turn scale off 0 Qa a oso 4 8 4 8 1 press and hold TARE then press ON OFF Scale displays F 1 press TARE twice Scale displays F 3 press and hold MODE press MODE unit the lb signs appear or select kg to disable the pound unit press ZERO to confirm and return to normal operation status If the pound weight is selected Press MODE to shift among lb and lb oz during operation TO TARE OFF THE WEIGHT OF A CONTAINER Place a container onto the platform then press TARE to tare off the weight of this container After TARE is pressed the tare sign appears To Clear Container Weight from Memory To clear the weight of the container remove the container and all loads from the platform and press TARE then tare sign would disappear Zero the Weight Displayed When Unloaded If zero sign does not appear when unloaded press ZERO to reset weight to zero PLACING A LOAD Always place a load onto the platform gently Sudden shock excessive force may cause damage to the weight sensor inside It is a goodpractice to remove all loads fromplatformimmediately after weighed This would prolong the life time of the weight sensor SELECT BACKLIGHT option STATUS
2. Toenable disablebacklight function press MODE until the desired status is attained Backlight would automatically go off 3 second after zero weight is detected and automatically turned on immediately after a load is detected WEIGHT MEMORY FUNCTION Save a Weight to Memory and Auto Weight Accumulation When weight display is stable press M to save Scale Displays P 1 and the M arrow appears indicating total number of total entries and the memory function is being employed 4 8 2 ao a pp Recall Weight Accumulated Press MR scale displays total number of entries and total accumulated weight of these translations Scale return to normal operation status 2 seconds after accumulated weight displayed Memory Clear Press andholdMR then press TARE afteraccumulatedweight display Scale displays P 0 and all data is cleared CAUTIONS ALL data stored will be erased if the scale is turned off weight unit is changed SELECT AUTO POWER OFF STATUS This unit is equipped with AUTO POWER OFF function Default setting auto off after 4 minutes unused Follow the below steps to disable employ the AUTO POWER OFF function turn scale off press and hold TARE then press ON OFF Scale displays F 1 press TARE for three times Scale displays F 4 press MODE to select to disable the auto power off function select O oFF F to employ the
3. auto power off unction select 4 oFF press ZERO to confirm and return to normal operation status 5 TROUBLE SHOOTING SYNDROME SCALE CANNOT BE TURNED ON CHECK ACTION CHECK CHECK ACTION Is the rechargeable battery charged Recharge the battery for at least 8 hours or plug in the mains adapter input Is the main adapter AC input inserted properly both to the wall outlet Is the output plug of the main adapter inserted properly into the DC inlet of the scale Secure both ends of the main adapter to the wall outlet and DC inlet of scale SYNDROME SCALE TURNED ON BUT ZERO WEIGHT CAN NOT BE ATTAINED CHECK ACTION CHECK ACTION SYNDROME CHECK ACTION Is anything load applied to platform Remove all loads from platform Is the scale affect by air flow vibration or RF Place scale away from all disturbances RATED CAPACITY CANNOT BE ATTAINED Is the TARE sign go on Turn scale off remove all loads from platform and turn of again CHECK ACTION SYNDROME CHECK ACTION CHECK ACTION CHECK ACTION CHECK ACTION CHECK ACTION SYNDROME CHECK ACTION CHECK ACTION SYNDROME SCALE DISPLAYS CHECK ACTION Anything obstructing the platform Remove all obstacles SCALE DOES NOT WEIGH CORRECTLY Is the Select right weight unit employed the right weight unit scal the Is the Adjust e placed horizontally adju
4. provided 1 3 1 3 1 Power on the Scale Check the input voltage of the main adapter scale matches with the voltage of electricity outlet Contact your local dealer if not Before first time operation plug the main adapter mains plug to the wall outlet and charge the scale for at least 8 hours Retain the package for future transportation of scale 2 SPECIFICATIONS GENERAL SPECIFICATIONS apacity IM 300 660 1b rm 600 1320 1b 0 2 1b Hastorn sizs ji x 23 6 Power source Built in rechargeable battery or power adaptor Max Tare range Up to 100 of rated capacity Max Zero range Up to 2 rated capacity etric decimal pound Note A and pound ounce Operation 0 40 C 32 104 F Environment Non condensed R H 85 Specifications subject to change without notice NOTE A To comply with the law of certain countries the avoirdupois weight units may be disabled Contact your dealer for more information 3 KEYBOARD LAYOUT AND DESCRIPTION UWE 2 ON OFF KEY Press this key to turn scale on or off 2 MODE KEY Press this key to switch between metric and avoirdupois weight units with or without backlight optional M KEY Press this key to enter present weight value into memory 4 MR KEY Press this key to recall the accumulated weight value in memory 5 TARE KEY Press this key to tare off the weigh
5. intelligent Weighing Technology LM SERIES BENCH FLOOR SCALE OPERATION MANUAL PLEASE READ THIS INSTRUCTION MANUAL VERY CAREFULLY BEFORE ATTEMPTING TO OPERATE THIS SCALE AUGUST 2003 REV 1 Specifications subject to change without prior notice CONTENTS 1 NSTALLAT ON 2 SPECIFICATIONS 3 KEYBOARD LAYOUT AND DESCRIPTION 4 INSTRUCTIONS FOR USE 5 TROUBL 6 DAILY CARE AND MAINTENANCE E SHOOTING NSTALLAT ON DIAGRAMS 1 2 3 N 1 2 4 INSTALLATION CHECK and make sure that the following accessories are included inside the package This Operation Manual Indicator x 1 Platform stainless steel cover x 1 Mains adapter x 1 Pillar x 1 and Screws amp tool set x 1 Contact your dealer if any items are missing FIXING THE PILLAR Thread the cable from platform through the pillar very carefully Insert the pillar to the pillar support attached to the platform in a upright position then locked it by the Allen head screw provided Connect the cable plug to the indicator receiving plug 3 1After plugs are connected lock the plugs by turning the plug screw in clockwise direction FIXING THE INDICATOR FOR FM amp LMMODELS Lock the indicator to the pillar by 2 screws
6. stable feet to obtain level condition fe Is the scale a vibration or RF ect by air flow Fa Place rom all disturbances scale away Is the scale calibrated correctly dealer Contact your local Is part of the load striking against the pillar Place load properly SCALE TURNED OFF AUTOMATICALLY Is the Auto Off Function employed Reset the Auto Off Function Is the LO BAT sign is on Recharge the battery or plug in the mains adapter input w 00000 wv xcesses th Is the weight of load max capacity Removed loads on platter and check again 6 DAILY CARE AND MAINTENANCE 6 1 Clean the platform and indicator with a soft and damp cloth if necessary with a mild detergent 6 2 Donot useany harsh abrasivematerial acetone volatile solvent thinner or alcohol for cleaning 6 3 Verify the accuracy of the scale periodically Re calibrate the scale when needed NOTE in some countries calibration is restricted to be done by qualified authorized agent only Contact your local dealer for more information 6 4 Clean the scale before long term storage 6 5 Store the scale in a dry and cool place 7 INSTALLATION DIAGRAM BM or FM amp LM gt Th 7 4 a Db f TT ay E arai N j LLI by a IP gt A BM TYPE B FM TYPE
7. t of a container and get the net weighing result 6 ZERO KEY Press this key to reset weight displayed to zero when unloaded 7 MC KEY Press the MR and TARE key simultaneously to clear all data in memory 8 ZERO INDICATOR An arrow will appear and point at this sign to indicate a zero weight status 9 TARE INDICATOR An arrow will appear and point at this sign when the tare function is being employed 10 M INDICATOR An arrow will appear and point at this sign when the memory contains data 11 WEIGHT UNIT INDICATOR kg indicates the metric unit is being employed Ib indicates the avoirdupois unit is being employed 12 LO BAT INDICATOR When this indicator appears recharge the scale immediately Failure to do so may cause unrecoverable damages to the rechargeable battery inside 13 IN CHARGE INDICATOR Red color Recharging battery Green color Charging completed 4 INSTRUCTIONS FOR USE 4 1 PLACING SCALE Use this unit on a hard and strong surface where is free from RF interference vibration fire direct sunlight and excessive moisture For accurate weighing always place this unit ona level surface if necessary adjust the adjustable feet underneath the platform to obtain a level condition 4 2 POWER THE SCALE Press ON OFF to turn scale on 4 3 INTERNAL SETTINGS Before weighing make sure the zero sign is on and stable 4 3 1 Select Weight Unit