1. LINKABLE STAND ALONE 10W LED PIN SPOT LED PS10D W User Manual Professional Entertainment Technology TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 Installation 4 How to Control the Unit 4 1 Control Panel 4 2 Master Slave operation 4 2 Easy controller 4 4 Universal DMX controller 5 DMX 512 Configuration 6 DMX 512 Connection 7 Trouble Shooting 8 Fixture Cleaning 1 Safety Instruction WARNING N Please read the instruction carefully which including important information about the installation Please keep this User Manual for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the unit Before operating ensure that the voltage and freguency of power supply match the power reguirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock The unit is for indoor use only and use only in a dry location The unit must be installed in a location with adeguate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect mains power before fuse replacement or servicing Replace fuse only with the same type Make sure there are not flammable materials close to the unit while operating as it is fire hazar
2. into a 3 pin XLR plug and plug it in the DMX output of the last unit Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable can not be branched or split to a Y cable DMX 512 is a very high speed signal Inadeguate or damaged cables solder joints or corroded connectors can easily distort the signal and shut down the system The DMX output and input connectors are pass through to maintain the DMX circuit when power is connected to the unit Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 512 usually 0 amp 1 are equal to 1 Theendofthe DMX 512 system should be terminated to reduce signal errors 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 5 Not used 7 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no light 11 Check the connection of power and main fuse 12 Measure the mains voltage on the main connector B Not responding to DMX controller 1 2 R DMX LED should be on If not check DMX connectors cables to see if link properly If the DMX LED is on and
3. UU00000000 ON 1234567 8910 3 M0ND0D0000 ON 12345678 910 4 EUMDDDO00 ON 12345678 910 4 3 Easy Controller by CA 8 CA 9 CA 9RTX A mode By connecting remote controller on Function and Mode The easy remote control is used only in master slave to the 4 pin jack of the first unit you will find that the the first unit will control all the other units for Stand by selection Blackout Blackout the unit Strobe Hold on the button Dimmer Hold on the 1 Synchronous strobe button Function 2 Chase strobe Dimmer 0 100 3 Chase strobe by sound activated Mode Sound LED OFF Dimmer LED ON 4 4 Universal DMX Controller When using a universal DMX controller to control the chain of units you can set DIP switch 10 OFF to select 3 channels mode and set it ON to select 4 channels mode After choosing channel mode you have to set DMX address by Dip switches from 1 to 9 to make sure all the units will receive its DMX signal Please refer to the following diagram to know how to address your DMX 512 system in the binary code DMX 512 Address Chart Dip switch es 1 2 4 3 4 5 6 7 8 9 10 12 2 h l Value 1 2 4 8 16 32 64 aine 6 mode Unit Dip sw
4. Performance
5. no response to the channel check the address settings and DMX polarity If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one Try to use another DMX controller Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit Some fixtures don t respond to the easy controller Check the LED for the response of the master slave mode signal Check if the unit is receiving DMX signal and cut it off No response to the sound Make sure the fixture does not receive DMX signal Check microphone to see if it is good by tapping the microphone E One of the channels is not working well The stepper motor might be damaged or the cable connected to the PCB is broken The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 10 Innovation Quality
6. d Use safety cable when fixes this unit Maximum ambient temperature is TA 40 C and dont operate it where the temperature is higher than this Unit surface temperature may reach up to 60 C Don t touch the housing bare hand during its operation There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by yourself In the unlikely event your fixture may require service please contact the nearest authorized technical assistance center and always use the same type spare parts Don t connect the device to any dimmer pack or power pack Do not look directly at the LED light beam while the fixture is on The housing must be replaced if they are visibly damaged Do not touch any wire during operation as high voltage might be causing electric shock 2 Technical Specification e Innovative design with powerful beam ideal for replacing traditional halogen Pin Spot No heat whiter and brighter e Different beam angles for different applications 9 for Mirror Ball and 13 for big mirror ball or as a table light e Optional easy controller CA 8 or CA 9 RTX for instant lighting shows at your fingertips e No heat low power consumption no duty cycle runs all night Ideal for clubs bars discos parties mobiles DJs etc e Voltage AC 100 240V 50 60Hz e LED 1 x 10W White LED 50 000 hrs rated e Power Consumption 10 6W e Dimension 187 x 156 x 115 mm e Weigh
7. itches setting Channel 1 dip on 1 1 ON 1234567530 Channel 2 dip on 42 2 2 A aja ujulujaluluin Channel 3 dip on 1 82 1 2 3 1231 010 L s Channel 4 dip on 3 4 OE 4 9000000080 ON 12345678910 Unit Dip switches setting Dip switch 10 ON i 1050000800 Channel 1 dip on 1 1 ON 12345678910 Channel 2 dip on 1 2 1 2 3 2 EN UUDD000D0D0N Channel 3 dip on 41 3 1 4 5 eee runo TN s nonanaann Channel 4 dip on 1 2 3 1 2 4 7 ON 7334557550 4 ODO ON 12345678 910 5 DMX 512 Configuration DMX512 Configuration 2 Channel Mode 1 Channel Mode Ch1 Ch1 Ch2 Dimmer Dimmer Strobe 255 100 255 0 248 255 Sound Active 444 8 247 F 0 7 No Strobe 6 DMX 512 Connection The DMX 512 is widely used in intelligent lightings and with a maximum of 512 channels O1 O 0 A O J m ci cil O Ci cil COMMON ouxineur of DMX OUTPUT DMX Termination reduces signal errors and voids signal transmission problems and interference It is always Gs advisable to connect a DMX terminal KR Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture If you using a controller with 5 pins DMX output you need to use a 5 to 3 pin adapter cable Atlast unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX
8. power supply 4 2 Master Slave Operation The unit can be linked together in daisy chain as many as you need in master slave mode the first unit will control the others to give a coordinate automatic light show and it s good for instant shows In Master Slave mode refer to the DMX settings below Master unit Set DIP switch 1 9 to OFF Slave units The DMX start address may set to any value but 0 gt 4 Light show Set dip switch 1 9 to OFF for the first unit which has nothing in its DMX input jack Set the DMX address of other units to 1 2 3 or 4 when the dip switch 10 OFF or set the DMX address of other units to 1 3 5 or 7 when the dip switch 10 ON then the units slave will follow the first unit master to run built in program for 4 Light show The slave units which don t set the address as mentioned aforementioned will run as slave 1 Dip switch 10 OFF Unit Dip switches setting Slave 1 dip on 1 1 Slave 2 dip on 2 2 1 A W00000000n Slave 3 dip on 1 2 1 2 3 Slave 4 dip on 43 4 2 lt pADDODDDM 3 UU00000008 ON 1234567 8910 4 9909000500 ON 12345678 910 Dip switch 10 ON Slave 1 dip on 1 1 Unit Dip switches setting Slave 2 dip on 1 2 1 2 3 1 ORL Slave 3 dip on 1 3 1 4 5 ON 12345678910 Slave 4 dip on 1 2 2 1 2 4 7 2
9. t 2 0kg B 187 213 137 56 ag o 115 CO CO 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 4 How To Control The Unit 4 1 Control Panel gt inn mu Hanging bracket With 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting hook Optical Lens Turn the lens to change the focus and obtain sharp gobos DIP Switches Set the different function settings Microphone Receives the sound to control the unit Only for remote control Connecting with CA 8 CA 9 CA 9RTX to control the unit for Stand by Function and Mode Safe Ring For attached the safe cable Heat sink for the LED Do not cover this part to ensure proper cooling DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal o DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit Mains input Connect to