Home

Journey User Manual

image

Contents

1. A CAUTION NEVER run the batteries completely flat As soon as the audible warning sounds complete the lifting operation in hand and place on charge A CAUTION NEVER store the power pack for long periods without regular charging throughout the storage period A CAUTION ALWAYS make sure the mains power to the charger is switched off before connecting or disconnecting the power pack UK EU Requirement A CAUTION NEVER leave the power pack plugged in to the charger with the mains power off UK EU Requirement A WARNING Do not charge an electric lift in a bathroom or shower room A WARNING Do NOT leave charger switched on with battery disconnected 294000 10050 Rev A Oxford Hoyer English Journey 9 Maintenance Schedule amp Daily Check List All Oxford Hoyer products are designed for minimum maintenance however some safety checks and procedures are required Schedules of DAILY tasks are detailed below Daily checks and a six monthly service inspection and test will ensure a lift is kept in optimum safe working condition A list of spare parts is available upon request The LOAD TEST and certification should only be carried out by qualified personnel or an authorised service agent dealer DAILY CHECK LIST Joerns Healthcare strongly recommends the following checks be carried out on a daily basis and before using lift e MAKE sure the lift moves freely on its castors e EXAMINE the spreader bar
2. OPERATION e The mast is fully locked into position see assembly instructions page 6 e The power pack is fitted to the lift and the latch holding the power pack in place is fully engaged A Click should be heard when it is in place IER 9 294000 10050 Rev A Oxford Hoyer English Journey e The up and down buttons on the hand control lower and raise the boom correctly 4 Sling Guide The Oxford Hoyer Journey is suitable for patients in the SITTING position The slings suitable for this device are listed as follows Oxford Hoyer Transport sling various sizes available Oxford Hoyer Standing sling various sizes available USER GUIDE FOR STANDAID SLINGS Both the Transport and Standing sling are easy fit slings suitable for standing and supporting They are not a general purpose sling Patients must always be assessed for suitability by a qualified person Transport Slin H g Attachment Loop Straps Shoulder ZC i amp x Chest Supports and Buckle Uf d Attachment Loop H Straps Legs Fitting Instructions Feed the sling down the back of the patient leaving the top of the commode aperture at the base of the spine Check the roll part of the sling is square across the patient s back Attach the support strap around the chest of the patient This strap need not be tight It is there to hold the sling in position while attaching the loops to the Stan
3. The legs on the Oxford Hoyer Journey are adjustable for width The legs can be opened to enable access around armchairs or wheelchairs For transferring and negotiating narrow doorways passages the lift legs should be in the closed position To achieve the adjustment the leg adjuster pedal located at the rear of the base is compressed right DOWN to open the legs outwards and left UP to close the legs The adjustment can be carried out with the patient in the lift but whether loaded or unloaded the adjustment should be made when the lift is moving 2 Castors and Braking The lift has two braked castors which can be applied for parking When lifting the castors should be left free and un braked The lift will then be able to move to its natural centre of gravity If the brakes are applied it is the patient that will swing to the centre of gravity and this may prove disconcerting and uncomfortable 3 Raising amp Lowering The Boom A powerful electric actuator that is controlled by a simple hand control unit achieves the movement of the boom The hand control has two buttons with directional arrows UP and DOWN NW The actuator stops automatically at its limit of travel in both directions The hand control plugs into a socket at the base of the control box 4 Emergency Stop The red Emergency Stop Button is located on the front of the control box and is activated by pressing it in This will cut all power to the lift and will only be reset
4. by twisting the button clockwise and releasing 14 294000 10050 Rev A Oxford Hoyer English Journey 5 Electrical Emergency Down Up Emergency lower down and raise up buttons are provided at the front of the control box Inserting a ballpoint pen into the button highlighted NN operates these buttons This will bring the boom up or down should the hand control fail at any time 6 Mechanical Emergency Down In the case of a complete electrical failure the electrical actuator is fitted with mechanical lowering device RED BOSS This will only operate when the lift is under load The device must be pulled upwards to activate and a slow descent will commence 7 Batteries A LOW VOLTAGE ALARM protects the batteries from deep discharge This will sound when the batteries need recharging and the hand control is being operated It will not sound independently of the hand control being operated DO NOT IGNORE THIS WARNING ALARM Complete the lifting operation and place the battery on charge see charging instructions The battery charge level is displayed by the indicator on the control box AWARNING The battery charger hand control control box and actuator should not to be opened by unauthorized personnel Contact your distributor for warranty and repairs 8 Slings The Oxford Hoyer Journey is suitable for patients in the SITTING position The slings suitable for this device are listed as follows e Oxford Hoy
5. cow horns is firmly attached to the boom e EXAMINE the sling hooks and attachment clips on the spreader bar and boom for excessive wear e MAKE sure the legs open and close correctly e OPERATE the hand control to confirm the boom raises and lowers satisfactorily e CHECK the operation of the emergency stop button e EXAMINE slings for fraying or other damage DO NOT use any sling if damaged e CONFIRM the lift is not giving a low battery alarm when the hand control is operated If the alarm sounds DO NOT use and place the battery on charge immediately MAINTENANCE INSPECTION AND TEST Joerns Healthcare recommends that a thorough inspection and test of the Oxford Hoyer Journey lift and lifting accessories and slings is carried out on a regular basis Inspection frequency varies from country to country so you must check with your dealer or local government agency as appropriate regarding how often an inspection is required The examination and test should be conducted according to the recommendations and procedures below Joerns Healthcare recommends maintenance inspection and certified testing is carried out by an authorized service agent dealers only NOTE These recommendations are in compliance with the requirements of 1998 No2307 Health and Safety The Lifting Operations and Lifting Equipment Regulations 1998 This is a UK regulation Outside the UK please check your local country requirements 21 294000 10050 Rev A O
6. 00 mm Weights Mast Base amp Boom Assembly 82 4 Ibs 37 4 kg FP MEE RA EE 6 2 Ibs 2 8 kg e NEE 88 6 Ibs 40 2 kg Base Assembly not inc hatten 30 2 Ibs 13 7 kg Mast amp Boom not inc battery 42 3 lbs 19 2 kg Fr 9 9 Ibs 4 5 kg NOTE Manufacturing tolerances apply to all dimensions ER 294000 10050 Rev A Oxford Hoyer English Journey ELECTRICAL SPECIFICATIONS BATI ERIE eie ee ese eee 24 volt Rechargeable sealed lead acid type BATTERY CAPACTTIYV ee ee ee ee ee 3 2 Ampere hours CHARGER RATED INPUT sa 100 240 V AC 50 60 Hz CHARGER RATED OUTRUT sees sees ee ese ee see ee ee ee ee 29 5 VDC Max 19 W Electric Shock Protection Re EE CLASS II EN 60601 1 LIFTINTERNAL POWER SOURCE Degree of Shock Protection RER TYPE B EN 60601 1 UT TYPE B EN 60601 1 ENVIRONMENTAL CONDITIONS Outside this environment functionality and safety may be compromised Operating Rull 5 C to 40 C Relative humidity EE 20 to 90 30 C not condensing Storage TENT EE 10 C to 50 C Relative UN EE Ee 20 to 90 30 C not condensing IP RATINGS entjie kes AE EE ae IP43 TN E IP54 Off Board Og re IP65 BE gs ee IP65 HR ee IP65 DUTY CYCLES UT OE A 10 2 min 18 min TE eessen Approx 4 hrs ACOUSTICS A Weighted sound power level ee RR 60 dB A 24 294000 10050 Rev A Oxford Hoyer English Journey KEY SYMBOLS The following symbols are used on the charge
7. ANY sloping surface e DO NOT use electric lifts in a shower e DO NOT charge an electric lift in a bathroom or shower room e DO NOT lift a patient unless you are trained and competent to do so e DO NOT use the lift or allow the lift to be used for any other purpose e DO NOT bump the lift down steps loaded or unloaded e DO NOT attempt to negotiate a loaded lift on a slope which exceeds 1 12 approximately 5 degrees e DO NOT attempt to negotiate a slope without a second helper being present e DO NOT use in a wet or corrosive environment such as poolside locations 18 294000 10050 Rev A Oxford Hoyer English Journey 8 Charging Instructions The batteries are located in the power pack and are charged via an off board desktop charger unit Removable Hand Control Battery Pack Boom Raise so Lower Buttons DE Ki 2 amp KI Control Box Battery Charge I Emergency Stop Level Indicator Button Boom Raise Lower Buttons When the power pack needs charging it can be removed from the lift and fitted to an off board charging unit The battery charge level is displayed by the indicator on the control box Joerns Healthcare recommends an additional battery pack is purchased so that one pack can be on charge at all times 1 Remove the power pack from the lift A simple latch at the top of the power pack retains the pack Lift the latch and the power pack will be released 2 Fit the pow
8. E A A A E E 26 2 294000 10050 Rev A Oxford Hoyer English Journey 1 The Oxford Hoyer Journey Patient Lift Push Handle Cow Horn TN Position Indicator Mast e Cow Horn Spreader bar Battery ii Attachment Hook Control Pack er Electric Hand Control Unit Actuator Kneepad Ka Adjustable Adjustment Kneepad Lever Mast Release Lever located on side of mast Op Rear Castor Front Castor Braked Non braked Removable Foot Tray READY FOR USE POSITION STORAGE POSITION 3 294000 10050 Rev A Oxford Hoyer English Journey 2 Introduction About Your Lift The Oxford Hoyer Journey is an electrically operated patient lift Each Journey lift is fully assembled load tested and certified before being packed shipped The packing consists of a strong purpose built carton to ensure the safe arrival of the lift A number of documents are supplied in a wallet and packed with each lift and should be kept safely for future reference TEST CERTIFICATE e USER MANUAL e DEALER GUARANTEE CARD Europe only e CUSTOMER SATISFACTION CARD Europe only e PACKING CHECK LIST The TEST CERTIFICATE is an important document and will be required for your insurance records It is valid for six months but after it has expired the lift should be inspected and serviced as per the maintenance schedule Your authorised dealer can carry out servicing and periodic testing f
9. Oxford Hoyer Oxford Hoyer Journey User Instruction Manual amp Warranty To avoid injury read user manual prior to use Oxford Hoyer Journey Manuel de l utilisateur et garantie Afin d viter tout accident veuillez lire attentivement la notice avant utilisation Oxford Hoyer Journey Manual de Instrucciones y Garantia para el Usuario Para evitar posibles dafios lea previamente el manual de usuario Oxford Hoyer Journey Benutzerhandbuch und Garantie Um Verletzungen zu vermeiden lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung Redefining patient handling Oxford Hoyer English Journey Mianufacturer s Contact Details Oxford Hoyer EUROPE USA Joerns Healthcare Ltd Joerns Healthcare Inc High Street Wollaston Stourbridge 5001 Joerns Drive Stevens Point West Midlands DY8 4PS Wisconsin 54481 5040 ENGLAND 715 341 3600 44 0 1384 44 66 22 800 826 0270 Fax 44 0 1384 44 66 01 Fax 800 457 8827 www joerns co uk www joerns com Contents 1 The Oxford Hoyer Journey Patient mt ee ee ee EA ee ee AA ge ge Ee 3 2 Introduction ABOUT YOUN LIM EE 4 3 Assembly amp Commissioning Insiruchons ee ee ee RR ee ee Re ee Re ee ee ee 5 2 MT NA 10 5 Lifting With Your Oxford Hoyer Journey uk 12 6 ETNE 14 Ts NOY Ge 17 RS rele GE Lon EE 19 9 Maintenance Schedule amp Daily Check List ee ek RR AR EA RA Re ee 21 10 Technical SPOCIICATIONS EE OE RE NN 28 AN EE AE EE N EE E
10. d Hoyer Journey carefully from the carton Lie the lift flat on the floor and ensure the rear castors are securely locked 5 294000 10050 Rev A Oxford Hoyer English Journey 2 To unfold the Oxford Hoyer Journey into its ready to use position raise the mast assembly upright This is achieved by pressing the mast release button located under the actuator as shown This will release the mast assembly and allow the mast to be raised Using the top of the push handle raise the mast to its upright position and locate the mast into the slot 1 Once the mast is firmly located use the mast locking lever to secure the mast This is achieved by pushing the mast locking lever down towards the mast surface 2 Finally release braked castors at the rear and the Oxford Hoyer Journey is ready for use 3 SAFETY NOTE Avoid trapping fingers Keep fingers away from the end of the mast when inserting into the mast slot Tighten the mast locking device and unlock the braked castors at the rear 6 294000 10050 Rev A Oxford Hoyer English Journey 3 Adjust the cow horn mechanism into one of three positions to suit either the patient task and or environment To adjust the cow horn simply pull the trigger backwards towards the rear of the lift while holding the cow horn Then select the desired position as indicated on the positioning decal 1 and release the trigger to lock The lift is now ready for operation CO me P
11. daid It may be left off altogether if preferred Ensure patients arms are on the outside of the sling refer to Fig C page 13 10 294000 10050 Rev A Oxford Hoyer English Journey Raise the patient s leg and feed the leg strap under and up between the legs Ensure the sling is not twisted or creased under the thigh Repeat this procedure for the other leg Attach the loops on the roll parts of the sling to the white hooks at the end of the handgrips Without crossing the loops on the leg straps attach to left and right hooks on the lifting fork You would normally use the middle of the three loops The patient is now ready to be raised from the seat Once clear of the seat the patient will be more comfortable if lowered back in to the sitting position Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage Do not use slings that are worn or damaged Standing Sling Attachment Loop Straps Chest Supports and Buckle Place the sling down behind patients back between base of shoulder blades and bottom of rib cage Attach the support straps around the front of the patient This strap need not be tight It is there to hold the sling in position whilst attaching the sling to the Standaid It may be left off altogether if preferred Ensure that the patient s arms are outside the sling refer to Fig A page 13 NOTE For detailed fitting instructions please
12. er Transport sling e Oxford Hoyer Standing sling 9 Knee pad adjustment The Oxford Hoyer Journey has an adjustable kneepad It is recommended for safety and ergonomic reasons that any adjustment is carried out by holding the top of the adjustment handle The range of travel is 10 2 inches 260mm Adjustment is achieved by following two easy steps STEP 1 turn the kneepad adjustment lever to the left to unlock STEP 2 either push handle downwards or pull handle upwards to select correct position Once the ideal position is found simply turn the kneepad adjustment lever to the right to lock in place NOTE the lever can be operated from either side of the lift 15 294000 10050 Rev A Oxford Hoyer English Journey 10 Removable footplate The Oxford Hoyer Journey has a removable footplate To remove the footplate move to the front of the Oxford Hoyer Journey and lift the footplate upward from the middle of the base assembly NOTE Be careful when removing the footplate from its low seated position as it is heavy Always use appropriate moving and handling techniques WARNING Always utilise the foot tray when standing or seating a patient Once the patient is in a standing position the foot tray may be removed for gait training 11 Adjustable cow horn The Oxford Hoyer Journey has an adjustable cow horn This allows the carer to position the cow horn in a comfortable position to suit the patient or environment The c
13. er pack to the charging unit The location and latching of the power pack to the charger is the same system as used on the lift 3 Plug the charger mains plug into a suitable mains outlet and switch the mains supply ON If applicable 4 Charging is automatic and will fully charge the batteries over a period of eight to twelve hours Note Even if the charger is left plugged in for extended periods it will not allow the batteries to overcharge 5 To return the lift to service switch OFF if applicable the mains supply and remove the power pack from the charger Fit the power pack to the lift and make sure the latch holding the pack in place is fully engaged Click in place The charging of Oxford Hoyer electric lifts is simple and straightforward but it is important to follow the charging instructions closely Please pay particular attention to the following points they will help you avoid problems with discharged batteries AWARNING The battery charger hand control amp control box are NOT to be opened by unauthorized personnel Contact your distributor for warranty and repairs AWARNING DO NOT touch battery charger terminals 19 294000 10050 Rev A 20 Oxford Hoyer Journey eil ed CAUTION KEEP the batteries fully charged Place the battery on charge whenever it is not in use If it is more convenient to do so place on charge every night The charger will not allow the batteries to overcharge
14. or those countries where this is a requirement Europe Please ensure your lift is included in their maintenance schedule If you are at all unsure what your local market servicing requirements are please check with your dealer a local government agency and or Joerns Healthcare The CE mark The Oxford Hoyer Journey carries the CE mark and complies with the following EC directives e Medical Device Directive 93 42 EEC C e EMC Directive 89 336 EEC Electrics only e Low Voltage Directive 73 23 EEC Electrics only 4 294000 10050 Rev A Oxford Hoyer English Journey 3 Assembly amp Commissioning Instructions CARTON CONTENTS Place the carton in a clear working area and open carefully The carton contains OXFORD HOYER JOURNEY LIFT BATTERY PACK WALLET CONTAINING DOCUMENTS CHARGING LEAD HAND CONTROL DESK TOP CHARGER STAND A WARNING The Oxford Hoyer Journey is heavy and will need to be lifted with care You may need assistance to lift the Oxford Hoyer Journey from the carton ASSEMBLY The Oxford Hoyer Journey is delivered in its folded storage position the following assembly process demonstrates the 3 easy steps required to take the Oxford Hoyer Journey from its storage position to its ready for use position This process is carried out with no additional tools required 1 Remove all the parts from the carton and place on the floor taking care to protect the finish from damage Lift the Oxfor
15. ore lifting a patient e DO NOT use a sling unless it is recommended for use with the lift e ALWAYS check the sling is suitable for the particular patient and is of the correct size and capacity e NEVER use a sling which is frayed or shows signs of damaged e ALWAYS fit the sling according to the instructions provided user instructions e DO NOT exceed the safe working load e ALWAYS check the safe working load of the lift is suitable for the weight of the patient e ALWAYS carry out lifting operations according to the instructions in the user manual e NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift e DO NOT lift a patient with the castor brakes on Always let the lift find the correct centre of gravity e DO NOT attempt to maneuver the lift by pushing on the mast boom or patient e ALWAYS maneuver the lift with the handle foot push pad provided e ALWAYS lower the patient to the lowest comfortable position before transfers e DO NOT push a loaded lift at speed which exceeds a slow walking pace 3 Km hour 0 8 metres second e DO NOT push the lift over uneven or rough ground Particularly if loaded e DO NOT attempt to push pull a loaded lift over a floor obstruction 17 294000 10050 Rev A Oxford Hoyer Journey EISEN e NEVER force an operating safety control All controls are easy to use and do not require excessive force e DO NOT park a loaded lift on
16. osition 1 L Position 1 Position 2 Position 3 Position 2 M HE Vil Position 3 5 al SR 1 Storage Fold NOTE See page 12 for cow horn position guidelines DISASSEMBLY To disassemble and store the Oxford Hoyer Journey follow the four easy steps shown below please note that no additional tools are required 1 Lower the boom into its lowest possible position and adjust the cow horn to the storage fold position as shown 7 294000 10050 Rev A Oxford Hoyer English Journey 3 Unlock the mast locking lever by pulling it outwards from the mast 1 Using the push handle lift the mast upwards and then slowly push downwards 2 carefully folding the mast assembly towards the legs until you hear a Click 3 The Click indicates the mast is now in its locked position NOTE If you wish to separate the mast and boom completely from the base and legs undo the mast locking lever fully remove pin assembly from mast and lift the mast and boom completely free from the base Be careful not to lose the mast lock lever and location spindle 8 294000 10050 Rev A Oxford Hoyer Journey NOTE Care should be exercised when folding unfolding the Oxford Hoyer Journey as there is a possible danger of trapping the fingers etc Please follow the instructions carefully and ask for assistance if you are unsure of the correct procedure English ALWAYS CHECK THE FOLLOWING BEFORE
17. ow horn has 3 positions Position 1 is more suitable for a large taller patient position 2 is more suitable for a medium average size patient and position 3 is more suitable for a shorter pediatric patient or when standing a patient from a low chair Please note these are guidelines only it may be necessary to adjust according to patient comfort To adjust the cow horn simply pull the trigger backwards towards the rear of the lift whilst holding the cow horn Then select the desired position as indicated by the positioning decal and release trigger to lock The cow horn has 3 alternative positions for lifting and a further one for the storage fold position mva Position 1 L Position 2 NM HEV Position 3 5 Lid 1 i Position 1 Position 3 Storage Fold Cow Horn Lift Positions 16 294000 10050 Rev A Oxford Hoyer English Journey 7 Safety Precautions Please read and follow the safety precautions listed below The operation and use of Oxford Hoyer patient lifts is simple and straightforward Following these few basic safety precautions will make lifting operations easy and trouble free READ AND UNDERSTAND THE USER INSTRUCTION MANUAL BEFORE USING YOUR Oxford Hoyer Journey A WARNING e ALWAYS plan your lifting operations before commencing e ALWAYS carry out the DAILY CHECK LIST before using the lift e ALWAYS familiarise yourself with the operating control and safety features of a lift bef
18. r control unit and battery Type B equipment as per EN 60601 1 Class 2 equipment oc gt The disposal of the charging and control unit should not be mixed with general household EW D The disposal of batteries should not be mixed with general household waste The disposal of electronics should not be mixed with general household waste For indoor use ATTENTION consult accompanying documents gt p bet Wee Producers registration number WEE GG0464R2 25 294000 10050 Rev A Oxford Hoyer ES Journey English 26 11 Warranty Joerns Healthcare has an established network of reputable distributors dealers and service providers who will be pleased to handle all your purchasing warranty repair and maintenance enquiries Our products are guaranteed for a period of 24 months from the date of manufacture or 24 months from the date of purchase if commissioned by an authorised dealer This guarantee covers the lift s major structure actuator and control box handset and battery for manufacturing defects failures We recommend that all of our products are commissioned by your dealer and are supported by them for future servicing The dealer or distributor operates the warranty programme so it is important to keep a record of their name address and telephone number so they can be contacted should any problem arise Europe only Failure to comply to the lift s servicing schedule may result in your wa
19. refer to the user guide supplied with each sling WARNING Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage DO NOT use slings that are worn or damaged WARNING Oxford Hoyer slings and lifters are not interchangeable with other manufactures products Using other manufacturers products on Oxford Hoyer products may be unsafe and could result in serious injury to patient or caregiver WARNING Refer to maximum weight capacity of lift Sling capacity is limited by the maximum capacity of the lift 11 294000 10050 Rev A Oxford Hoyer English Journey 5 Lifting With Your Oxford Hoyer Journey The Oxford Hoyer Journey has an adjustable cow horn This allows the carer to position the cow horn in a comfortable position to suit the patient or environment The cow horn has 3 positions Position 1 is more suitable for a large taller patient position 2 is more suitable for a medium average size patient and position 3 is more suitable for a shorter pediatric patient or when standing a patient from a low chair Please note these are guidelines only it may be necessary to adjust according to patient comfort To adjust the cow horn simply pull the trigger backwards towards the rear of the lift whilst holding the cow horn Then select the desired position as indicated by the positioning decal and release trigger to lock The cow horn has 3 alternative po
20. rranty being invalid If you are in doubt where your lift was purchased Joerns Healthcare can trace the supplier if you quote the serial number of the lift REMEMBER Contact your distributor for purchases warranty repairs servicing and certified maintenance Your Dealer Distributor 294000 10050 Rev A Oxf H English xford Hoyer E Journey 27 294000 10050 Rev A KA Joerns Healthcare Joerns Healthcare Inc Joerns Healthcare Ltd 5001 Joerns Drive High Street Wollaston Stevens Point WI 54481 5040 Stourbridge West Midlands USA DY8 4PS 715 341 3600 ENGLAND 800 826 0270 Tel 44 0 1384 44 66 22 Fax 715 341 3962 Fax 44 0 1384 44 66 01 2008 Joerns Healthcare 294000 10050 Rev A
21. s test procedures It is strongly recommended the testing is carried out by an authorised service dealer BASE AND WHEELS Ensure base is even and level all four wheels are on the floor SLINGS Check for wear and fraying LUBRICATION Lubricate pivot joints with a silicone based oil including mast and boom connections pedal assembly spreader bar joint only if required HAND SET Ensure plugged fully into controller 22 294000 10050 Rev A Oxford Hoyer English Journey 10 Techinical Specifications Safe Working Load E 341 Ibs 155 kgs Maximum Overall Length ee ee RR Re Re 36 6 inches 1000 mm Minimum Overall e E 35 2 inches 925 mm Maximum Overall Hehe 55 5 inches 1610 mm Minimum Overall Heabt ees ees ee ke ke Re Re Re 44 1 inches 1130 mm Maximum Height to attachment point 62 0 inches 1550 mm Minimum Height to attachment pont 27 4 inches 735 mm TORING GE 43 2 inches 1145 mm Legs Open External Width ee ee Re Re 37 4 inches 980 mm Legs Open Internal With 30 1 inches 895 mm Legs Closed External Width 26 6 inches 695 mm Legs Closed Internal Width ee ee Re Re 23 5 inches 620 mm Widest Point between support handles 0 18 8 inches 475 mm Overall Height of Legs ees ee ee 4 5 inches 110 mm Ground Clearance ee ee ee ee ge 1 2 inches 30 mm Seidel 3 0 inches 75 mm Rear Braked Castors s mmseamsvaasvrrvernvernvernvvrsnvrsnersnvernre 4 0 inches 1
22. sitions for lifting and a further one for the storage fold position Cow Horn Lift Positions mal Position 1 L Position 2 NM EEA Position 3 5 Position 3 Storage Fold Lifting from a sitting position Select the most suitable cow horn position to suit the patient or environment Once complete position the Standaid so that the patient s feet fit in the foot tray and the knees rest against the kneepad adjust knee pad accordingly and fit safety belt if required Attach the loops of the sling to the grey hooks at the end of the Oxford Hoyer Journey handgrips The patient s hands should be placed on the handgrips see Fig A or C Prior to lifting make a visual check to ensure the loops of the sling are secure and in place Then push the UP button on hand control to raise the patient to the standing position see Fig B or D 12 294000 10050 Rev A Oxford Hoyer English Journey Standing Sling TRANSPORT SLING NOTE Joerns Healthcare recommends a risk assessment be completed before carrying out your lifting operation WARNING Always utilise the foot tray when standing or seating a patient Once the patient is in a standing position the foot tray may be removed for gait training 13 294000 10050 Rev A Oxford Hoyer English Journey 6 Operating Instructions Operating controls for the Oxford Hoyer Journey lift Operating Instructions 1 Leg Adjustment
23. xford Hoyer English Journey THESE CHECKS SHOULD INCLUDE Before Use Initially Service Intervals BOOM Check the attachment of the boom to the mast Make sure there is only minimal side movement of the boom and the boom is free to rotate on the boom bearing MAST Check the operation of the mast locking device Make sure the mast fully engages into the socket COW HORN Check cow horn is engaged and in correct position ACTUATOR The actuator should require no maintenance other than checking for correct operation and listening for unusual noise KNEE PAD Check knee pad adjuster is fastened securely POWER PACK Check the function of the emergency stop button and emergency lower BATTERIES The batteries are housed in the power pack and should not require maintenance other than the regular charging as detailed in the charging instructions Check that the connections remain clean LEG ADJUSTMENT Check the legs operate in both full extensions inward outward CASTORS Check all castors for firm attachment to the legs Check for free rotation of the castor and the wheels CLEANING Using a damp cloth wipe clean with ordinary soap and water and or any hard surface disinfectant Harsh chemical cleaners or abrasives should be avoided as these may damage the surface finish of the lift Avoid wetting any of the electrical parts LOAD TEST The load test should be carried out in accordance with the manufacturer

Download Pdf Manuals

image

Related Search

Related Contents

Interruttore di sicurezza  Panasonic 7160-0318-12  ICC ICMB89D0WH patch panel accessory  User`s Manual - MARUSON Technology Spanish  MooreCo 34556 chair  OPERATING INSTRUCTIONS LP-FLOWETCH  Wiley Adobe Photoshop Lightroom Workflow: The Digital Photographer's Guide  manual - Estaciones totales  User Manual - Wet Sounds  Barreiras PA e FF  