1. USER MANUAL PEN 01 ADAPTER TO PENDRIVE Plik 2015 03 30 PEN 01 PEN_45 GB MAXIS 1 General description Adapter enables to save data send from measurement device for example from scale to USB memory pendrive Data is saved in a file which can be readout after disconnecting the pendrive and connecting it to computer To readout file any text editor can be used Copying file can be done by typical computer programs or Windows tools one way communication with any device equipped with RS232C connection possibility of saving a timestamp of incoming data possibility to connect pendrive with any capacity using USB connection supply from RS232C interface or from external feeder 2 Set Basic kit includes Adapter PEN 01 to pendrive External fedder if necessary Pendrive Manual Cable WP 1 option NA2AON 3 Technical specification Type PEN 01 Interfaces RS232C DB 9 USB type A USB control diode continuous lighting ready to write blink during transmission Signaling RS232 control diode continuous lighting power supply blink during transmission File system FAT12 FAT16 FAT32 Supply 12 VDC 100mA using RS232C or external feeder Dimensions 72x41x24mm Weight 40g MAXIS RS232C interface diagram PEN 01 TxD nadawanie RxD odbi r masa 4 Options of connecting adapter to measurement equipment and pendrive Standard option with external feeder EXTERNAL FEEDER option
2. 230V PEN 01 PENDRIVE MEASURE EQUIPMENT gt m O Option with USB extension conduit supply by RS232C bona PEN 01 CABLE USB 2 0 AM FM PENDRIVE MEASURE e me EQUIPMENT gt ll El AAA O Option with RS232C extension conduit supply by RS232C interface CABEL WP 1 PEN 01 PENDRIVE lt gt Oo _ MEASURE EQUIPMENT MAXIS 5 Adapter configuration After connecting pendrive to adapter adapter tries to open config txt file and readouts configuration parameters If there isn t configuration file in the pendrive main catalog it will be created and it will set default parameters To change the parameters user should edit config txt file using computer and a text editor 5 1 Configuration by using PEN software User can create config txt file by using PEN The software creates file automatically Program PEN is located on a CD or is available on company website www axis pl Main window appears after installation of program AXIS PEN v1 02 Program do konfiguracji PEN 01 Ustawienia urz dzenia Transmisja Pr dko 4800 w Data i czas Ustaw date 11 06 14 _ Ustaw czas 08 52 foo AXIS Sp zoo ul Kartuska 375B Gda sk 80 125
3. tel 4 320 63 01 03 P m 7 wozy 7 Domy lne Otw rz Zapisz Zapisz jako Zako cz E Mal axis AXIS D WWW axis p User can choose option by proceed a proper check box In bookmark Logowanie do pliku button Zapisz enables record a new config txt file to connected pendrive Choosing optons are displayed in text field on the right side of screen AXIS PEN v1 02 PEN rogram do konfiguracji PEN 0 z z did i lt a Logowanie do pliku c Nazwa pliku jlog txt Automatyczne numerowanie plik w O 8 E Podgl d przyk adowego pliku z logami Logowanie daty i czasu Logowanie daty Logowanie czasu ci g wyzwalaj cy zapis daty czasu rin Okres wyzwalania zapisu daty czasu o s AXIS Sp 20 0 ul Kartuska 375B Gda sk 80 125 NN E mail axis axis WWW OXIS D MAXIS k Bookmark Praca cykliczna enables recurrent record of indication on pendrive AXIS PEN v1 02 PEN Ustawienia urz dzenia Logowanie do pliku Praca cykliczna Program do konfiguracji PEN 01 m A lt a Praca cykliczna Polecenie Przedzia czasu AXIS Sp 20 0 ul Kartuska 375B Gda sk 80 125 e mall axis axis p WWW OXIS D 5 2 Configuration by edition of file only for advanced users Manual editing of configuration file enables to change all necessary parameters Each line of a configuration file should be written in a following way PARAMETER NAME VALUE If partic
4. After diode supply is on both diodes light for about 0 5 second MAXIS DIODA_RS232 Event State Diode RS232 Adapter isn t supplied Light off Adapter is supplied Light on Transmission is in progress on RS232 receiving line DIODA_USB Event State Diode USB Pendrive is disconnected or unidentified or full Light off Pendrive is ready Light on Pendrive with configuration file is connected and all parameters are recognized correctly Pendrive without configuration data Configuration file has been created with default data Pendrive with configuration file but one of the following problems occured unidentified parameter in configuration file identified parameter has incorrect value Data portion saved on Pendrive Data portion saved on Pendrive but there is no free space available configuration file is too big ANT 7 RS232C commands The whole transmission from RS232 port is saved on Pendrive Exception is situation when byte with 0x10 value shows up Device recognizes this as a marker successive bytes are interpreted as a command for the device Device ends interpreting successive bytes as command after 0x10 sign shows up again Following command are recognized main catalog listing o plik txt readouts plik txt file by RS232 interface d 2010 04 11 data setting c 08 00 00 time setting MAXIS Notes AXIS Sp zo o
5. it exists transmission will be added at the end of file Parameter PATH can have following sequences Y year added two last digit of year M month WD day H hour AN minute AS second Default LOG TXT Example PATH FOLDER1 RESULTS TXT Name AUTO_NAME Description Parameter can have YES or NO value If NO is set it means that after taking out the pendrive and connecting it once again RS232 transmission will be saved to the same file defined by PATH parameter If YES is set each taking out and in will create new file where the transmission will be saved New files names will be created using file name PATH parameter and successive numbers for example LOG00001 TXT LOG00002 TXT LOG00003 TXT etc If the numbers run out instead of next number X sign will show up Default NO Example AUTO_NAME YES Name BAUD Description Setting RS232 transmission speed Available 2400 4800 9600 14400 19200 38400 56000 57600 115200 Default 4800 Example BAUD 9600 Name DATE Description If this parameter is present in configuration file date will be set and this parameter will be preceded with signs to avoid changing data during next pendrive inserting Format YYYY MM DD Default Data doesn t change Example DATE 2010 04 11 MAXIS Name TIME Description If this parameter is present in configuratio
6. ul Kartuska 375B 80 125 Gda sk Poland tel 48 58 320 63 01 03 fax 48 58 320 63 00 E mail axis axis pl www axis pl
7. ill not be write to file E3 protocol Eltron identifier of label will not be write to file indication will be write to file name identifier of label txt independently of PATH setting PARAMx x can be set from 1 to 8 saving data to different files depending on chosen parameter Parameter number is related to active positions in Print function in balances If second position send from scale is product identification number and user sets protocol to PARAM2 then separate measurements files will be created depending on product ID created files will have different product ID s as their names Default NONE Configuration file example CONFIG FILE VER 46 PATH LOG TXT Path to log file AUTO_NAME NO Allowed values YES NO BAUD 9600 Allowed values 2400 4800 9600 14400 19200 38400 56000 57600 115200 DATE 2010 01 01 Date format YYYY MM DD TIME 08 00 00 Time format HH MM SS LOG_DATE YES Allowed values YES NO PL EU US LOG_TIME YES Allowed values YES NO PL EU US TRIG TOKEN r n Max 20 characters TRIG_PERIOD 0 0 999999 sec COMMAND SI r n Max 20 characters INTERVAL 0 0 999999 sec ECHO NO Allowed values YES NO PROTOCOL PARAM1 Allowed values NONE E1 E2 E3 PARAM1 PARAM8 CONFIRMATION NO Allowed values YES or NO 6 Signaling DIODA_USB diode closer to USB interface DIODA_RS232 diode further from USB interface
8. in format e g 2 32 58pm NO time isn t stored Default NO Example LOG_TIME YES Name TRIG_TOKEN Description This parameter specifies sequence of characters which should make timestamp to be inserted in a log file Maximum size of this sequence is 20 characters Timestamp will be placed in a log file behind recognized sequence of characters Empty TRIG_TOKEN means There is no sequence of characters which should make timestamp to be inserted in a log file Default Vin r code 13 in code 10 ENTER Example TRIG TOKEN empty Name TRIG PERIOD Description This parameter specifies minimum period of time which has to elapse after last timestamp to cause that next data reception will make timestamp to be inserted in a log file If during reception of byte of data through RS232 port PEN 01 finds that time which elapsed after last timestamp is larger than TRIG PERIOD it will insert next timestamp to the log file just before this byte If this parameter eguals zero it means that elapsing time won t make timestamp to be placed in the log file Default 5 Example TRIG PERIOD 10 MAXIS Name PROTOCOL Description This parameter term which protocol can be understandable by interface NONE any protocol are choose all bytes are writing to file E1 protocol Eltron identifier of label will be write to file E2 protocol Eltron identifier of label w
9. n file time will be set and this parameter will be preceded with signs to avoid changing data during next pendrive inserting Format GG MM SS Default Time doesn t change Example TIME 08 12 45 Name COMMAND Description Command which should be sent through RS232 port at specified intervals Maximum size of command is 20 characters Empty command means don t send anything Default Empty Example COMMAND SI Name INTERVAL Description Interval at which command should be sent expressed in seconds If this parameter equals zero it means that command won t be sent Default 10 Example INTERVAL 20 Name ECHO Description This parameter determines whether command sent to RS232 port should be logged to file or not Allowed values YES or NO Default YES Example ECHO NO Name LOG_DATE Description This parameter determines whether transmission date should be stored and sets date format Allowed values YES transmission date in PL format e g 2015 03 20 PL as above US transmission date in USA format e g 03 20 2015 EU transmission date in format e g 20 03 2015 NO without transmission date Default NO Example LOG_DATE YES MAXIS Name LOG_TIME Description This parameter determines whether transmission time should be stored and sets time format Allowed values PL transmission time in format e g 14 32 58 YES as above EU as above US transmission time
10. ular line contains such a sequence of characters II it means that everything following this sequence is a comment and won t be interpreted by PENDRIVE interface as a parameter name or value Values of parameters can by placed directly after character or can by placed in the guotation marks if parameter contains white spaces value of this parameter has to be put in guotation marks If the configuration file doesn t contain particular parameter or the value of this parameter is incorrect then the value of the parameter will be set to default It is possible to use control codes in configuration file by using special escape character Y character This character causes fallowing it characters to be interpreted in a different way than usual Possible escape seguences are ib Backspace same as 1x08 M FormFeed same as X0C in Newline same as 1x0a r Carriage Return same as 1x0d t Horizontal Tab same as x09 x lt 2 hex digits gt code of character e g x4e means N character X lt 2 hex digits gt same as above means character means character lt anything else gt treated as if there where no V character Maximum size of configuration file is 1KB MAXIS Parameters that can be modified Name PATH Description Path to file plus file name 8 3 format where transmission is saved If the file doesn t exist it will be created If