Home

ZIG-SW42 User Manual

image

Contents

1. See note above chroma subsampling or color compression is related to bit depth and video resolution settings with regard to total bandwidth requirements A 4K 60 signal at 4 4 4 chroma subsampling can have a maximum bit depth of 8 bits Audio HDMI in amp Out Up to Dolby TrueHD and DTS HD Master SPDIF Up to Dolby Digital amp DTS 5 1 Audio Sampling Rates Up to 1536 KHz Distance HDMI Up to 5M 4K HDBaseT Up to 100M at 4K 60 4 2 0 8 bit HDCP 2 2 1 4 or None CEC Pass through Connections 4 x HDMI type A HDMI Input 1 x HDMI type A HDMI Output 1 x RJ45 HDBaseT 100M Port 1 x SPDIF Digital Audio Output 1 x RJ45 LAN Port for TCP IP Control 1 x 9 pin RS 232 port 1 x 3 5mm IR In Port 1 x 3 5mm IR Out Port 1 x 5 pin Locking IR Connection phoenix in out 3 12 VDC 1 x IR Sensor In 1 x IEC 110 220VAC 6 ZIG SWA2 USER MANUAL ZIGEN Temperature Operating 32 122 F 0 50 C Humidity 20 90 non condensing Dimensions 1RU Rack Mountable Weight 3 Pounds Certifications Compliance FCC HDBaseT CE RoHS HDCP HDMI ZIQencorp com Toll Free 877 650 5252 International 1 818 654 5252 Front Remote Back UHD Media Player Input Select Power Light 2160P60 4 4 4 UHD Projector i Web0OS Interface Router UHD Media UHD Media UHD Media Player Player Player Multi Zone Amp 3 Party Controller ZIG SW42 HDMI 2 0 600 MHz Switch with HDCP 2 2 Web0OS Interfac
2. arising from the use of such defective products whether such damages be direct indirect consequential or otherwise and whether such damages are incurred by the reseller end user or any third party The information in this manual has been carefully checked and is believed to be accurate However ZIGEN assumes no responsibility for any inaccuracies that may be contained in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice 18 ZIG SW42 USER MANUAL
3. device Always unplug the power to the device before cleaning Unplug the power cord during lightning or after a prolonged period of non use to avoid damage to the equipment ZIQencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Introduction New 600 MHz HDMI switch designed for switching in home and commercial environments where switching of high bandwidth UHD 2160P60 4 4 4 content is required or just to be safe for future sources including the new blu coming this fall The SW42 features 4 HDMI 2 0 Inputs and 1 HDMI 2 0 output digital audio de embedding of active channel and an Ethernet port and WebOS for setup switching EDID management firmware updates and remote reset Additionally the SW42 is controllable via built in IR receiver or RS 232 The SW42 also has a mirrored HDBaseT 100 meter port single CAT5e of higher SW42 also routes Ethernet and is compliant with the entire Zigen ecosystem of products by routing network commands and control in receiver nodes Typical Applications e Classrooms Boardrooms Conference rooms for switching UHD content sources via multiple control options 3 party controllers WebOS simple remote or front panel buttons e High end home theaters for showing UHD 2 0 content with HDCP 2 2 copy protection e Long distance applications where the rack is up to 100 meters from the display Package Contents e 1x ZIG SW42 e 1x 12V 2 5A DC Power Supply e IEC US
4. A AC Cord 3 e Remote Control e 1x User Manual Features HDMI 2 0 600 MHz UHD on all ports 18 GBP sec video bandwidth WebOS Interface Supports digital video formats up to 4K UHD 2160P60 4 4 4 pixel format e Advanced EDID management 4 ZIG SW42 USER MANUAL ZIGEN e Supports uncompressed PCM 2 Ch 5 1 7 1 Dolby Digital DTS Dolby TrueHD DTS HD Master Audio and more e Built in IR sensor plus 3 5mm jack and remote control e IR In and Out jacks plus locking style phoenix connector 3 12VDC works with everything e Bi directional RS 232 Control switch or integrate 3 party control e SPDIF for audio de embedding e HDCP 2 2 compliant Specifications Video Bandwidth HDMI 18 GBP sec HDBaseT 10 2 GPBS Max Video Resolutions All SMPTE amp VESA in HDMI 2 0 Specification Max SMPTE UHD 4096x2160P60 RGB 4 4 4 8 bit Max for HDBaseT port is 2160P60 4 2 0 8 bit HDBaseT CAT limitation Color Space RGB YUV Color Bit Depth 8 bit 10 bit 12 bit amp 16 bit per pixel Note Resolution and video bandwidth limited ex 2160P60 RGB or 4 4 4 8 bit would use almost the entire 18 GBPS of bandwidth 2160P60 4 2 2 10 bit new Blu Ray would exceed the previous 10 2 GBPS maximum of HDMI 1 4a and would not be able to travel over category cable using HDBaseT as of this writing zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Chroma Subsampling 4 4 4 4 2 2 4 2 0
5. P 1 EDID OFF UP As a default the downstream EDID is copied and used from output port 1 While DIP 1 is OFF UP DIP 2 amp 3 are active as follows DIP 2 OFF UP audio according to downstream capabilities DIP 2 ON DOWN audio is restricted to 2 channel regardless of downstream EDID DIP 3 OFF UP audio according to downstream capabilities zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN DIP 3 ON DOWN audio is modified for SPDIF maximum capabilities This ensures that the SPDIF output always outputs all SPDIF supported formats DIP 2 overrides DIP 3 If DIP 2 is down stereo is selected While DIP 1 is ON DOWN the EDID is selected using the WebOS WebOS has 15 EDID tables to select from more to come for various use cases see screen shot below Additionally via the WebOS and custom EDID table can be loaded into the device This gives maximum flexibility as customers can load any EDID they want for the desired application 2160p30 HD Audio 2160p30 5 1 Audio 2160p30 2ch Audio 1080p 3D HD Audio 1080p 3D 5 1 Audio 1080p 3D 2ch Audio 1080p 5 1 Audio Hardware 0001 1080p 2ch Audio 1080 5 1 Audio 1080i 2ch Audio Screen Shot EDID Tables in WebOS Note While DIP 1 is ON DOWN DIPs 2 and 3 are not used DIP 4 Hot Plug Force UP OFF Hot Plug Detection HPD is normal 10 ZIG SW42 USER MANUAL ZIGEN DOWN ON HPD is forced active In this mode the SW42
6. Y with the exceptions noted in the next paragraph ZIGEN warrants the original purchaser that the equipment it manufactures or sells will be free from defects in materials and workmanship for a period of three years from the date of purchase The proof of sale is required in order to claim warranty Should this product in ZIGEN s opinion prove defective within this warranty period ZIGEN at its option will repair or replace this product without charge Customers outside of US are responsible for shipping charges to and from ZIGEN Any defective parts replaced become the property of ZIGEN This warranty does not apply to those products which have been damaged due to accident unauthorized alterations improper repair modifications inadequate maintenance and care or use in any manner for which the product was not originally intended for Items integrated into ZIGEN products that are made by other manufacturers notably computer hard drives and liquid crystal display panels are limited to the term of the warranty offered by the respective manufacturers Such specific warranties are available upon request to ZIGEN ZIGEN makes no other representation of warranty as to fitness for the purpose or merchantability or otherwise in respect of any of the products sold The liability of ZIGEN with respect to any defective products will be limited to the repair or replacement of such products In no event shall ZIGEN be responsible or liable for any damage
7. ZIGEN Zigen SW42 HDMI 2 0 UHD 600 MHz 4x1 Switch w HDCP 2 2 amp WebOS Mirrored Long Distance HDBaseT 100M Port ZIG SW42 USER MANUAL Ver 1 0 ZIgENCOrP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Table of Contents Copyright and Trademark 3 Introduction 4 Package Contents 4 Features 4 Specifications 5 Block Diagram 8 General Operation 9 Dip Switch Settings 10 Remote Control 12 WebOS 13 Commands 16 Warranty 18 2 ZIG SWA2 USER MANUAL ZIGEN Copyright and Trademarks All rights reserved by ZIGEN INC No part of this document may be reproduced in any form or by any means without written permission from the product manufacturer Changes are periodically made to the information in this document They will be incorporated in subsequent editions The product manufacturer may make improvements and or changes in the product described in this document at any time All the registered trademarks referred to this manual are belonging to their respective companies Before You Begin Follow all instructions marked on the device during using Do not attempt to maintain the device by yourself any faults please contact your vendor Provide proper ventilation and air circulation and do not use near water It is better to keep it in a dry environment The system should be installed indoor only Only use the power cord supplied with the device Do not use liquid or aerosol cleaners to clean the
8. does not process HPD events from downstream to upstream from the sink back to the source This speeds up the HDMI pipeline and can be very useful to avoid a looping condition when multiple HDMI devices are connected in series ZIQencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN ZIG SW42 Remote Control ZIGEN ECN EN on or POWER SW42 remote control can be used for switching between inputs and powering the SW42 up or down 12 ZIG SW42 USER MANUAL PB ZIG swa1 CG fi Di sw41 0000 ZIGEN ZIG SW41 Control Panel Device Name sw41 0000 Notes Save Notes Video Input Edid Management For custom edid tables make sure dip1 is ON down Active edid table downstream New edid table v Upload custom edid file sw41 edid Choose Files No file chosen Upload Edid Serial 123456780000 Firmware 0 98 Hardware 0001 IP Address 192 168 1 113 Hostname sw41 0000 Change Name Factory Reset Choose Files No file chosen Upload Firmware Reset SW41 Install Update zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN SW41 2 Web OS Screenshot WebOS Device Name amp Notes e Device Name default out of the box is SW42 XXXxX last 4 digits of the serial number Example for PC http sw42 0001 for Mac http sw42 0001 local You should change it if you are using more than 1 device Change Name be
9. e Mirrored Output 8 ZIG SW42 USER MANUAL ZIGEN Block Diagram Zigen ZIG SW42 General Operation SW42 is the ultimate in high bandwidth UHD switchers With a full 600 MHz pixel clock the SW42 support high bandwidth sources and displays Additionally the SW42 supports HDCP 2 2 copy protection so you can be sure your customer is able to view the latest 4K UHD content either protected movies or computer content un protected Basic connections are 4 HDMI 2 0 sources or below and one HDMI output to the display or projector There is a SPDIF port that de embeds audio from the currently selected input and routes it to your audio matrix or multi zone amplifier Additionally with the SW42 there is a 100 meter HDBaseT port for long distance runs Note HDBaseT is limited to 4K 60 4 2 0 8 bit Advanced EDID management is available through a combination of the 4 pin dipswitch and WebOS 15 EDID tables are available plus you can load custom EDID tables Or leave the SW42 in the default mode and it will pull the EDID from the connected selected display By being able to manage the EDID and HPD Hot Plug Detection you can speed up switching in mixed format systems Control the SW42 via the supplied remote control IR to built in sensor or run an IR receiver to the 3 5mm IR jack You can also control the SW42 via 3 party control RS 232 LAN WebOS Telnet or via the input selector switch on the front panel DIP Switch Settings DI
10. is for installing new software updates to the unit ZIQencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Command Syntax RS 232 amp IP Commands note the same commands are available via RS 232 and IP use for RS232 nothing for IP RS 232 SW42 XXXX last 4 of SN lt sp gt lt parameter gt lt sp gt lt parameter gt lt sp gt lt end of response gt Default RS232 Protocol Settings can be changed in WebOS if required Baud Rate 115200 Data Bits 8 Parity None Stop Bit 1 Flow control None IP DA 14 XXXX lt sp gt lt parameter gt lt sp gt lt parameter gt lt sp gt lt end of response gt Commands shown in RS 232 format Help SW42 XXXX help Shows a list of available commands Disco SW42 XXXX disco Uptime SW42 XXXX uptime Shows day hours minutes and seconds the SW42 has been running 16 ZIG SW42 USER MANUAL ZIGEN Version SW42 XXXX version Shows Zigen SWA42 firmware release firware revision build date and serial number Get Device Status SWA42 XXXX st Shows active and inactive ports ex Port 1 active port 2 off etc HDMI Input Selection SWA42 XXXX insel lt 1 2 3 4 gt Lets you change the input Power SW42 XXXX lt on or off gt Powers device on or off Ports remain active no picture or sound ZIQencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Warranty Information LIMITED WARRANT
11. low to whatever you want ex CR100SW for conference room number 100 switcher e Notes free form field for entering installer notes Video Input e Use to select the input you want showing on the display EDID Management 2160p60 HD Audio 2160p60 5 1 Audio 2160p60 2ch Audio 2160p30 HD Audio 2160p30 5 1 Audio 2160p30 2ch Audio 1080p 3D HD Audio 1080p 3D 5 1 Audio 1080p 3D 2ch Audio 3 1080p 5 1 Audio Hardware 0001 10805 Sen Ande 1080i 5 1 Audio 1080i 2ch Audio Factory Reset 14 ZIG SW42 USER MANUAL ZIGEN Note To use WebOS EDID management make sure DIP 1 is ON UP Active EDID table is shown You can load one of the presets from the previous page or load a custom EDID table from your PC simply browse and upload the custom EDID if required Admin Firmware Reset Info Serial Number serial number of SW42 Firmware Current firmware revision Hardware for internal use IP Address IP address of the unit assigned by your DHCP Server Hostname this is what you want to call the unit syntax example CR100RX_k123 This is also the name you type into your browser to access the WebOS Don t us spaces or special characters e Factory Reset will erase user entered date like installer notes e Choose File Upload Firmware when necessary this is where you select a new firmware file and upload firmware e Reset DA14 will reset the ZIG SW42 remotely e Install Update when necessary