1. Device load turned off LED turns off Device load dimming LED keep in previous stage Device not currently paired LED will continuously flash two times per second into a Z Wave network If the device already existing in the network LED will flash i 7 slowly for 2 seconds and then return to previous ON or Learning NWI mode OFF stage Triple click on PROG button If the device does not exist in the network LED will keep flash slowly and waiting for Network Wide Inclusion NWI The device will exit NWI mode automatically after 5 seconds Receive command Send LED will flash 2 times and then return to previous ON or command or data OFF stage Configure command error LED will rapidly flash 6 times and then return to previous ON or OFF stage Restoring Factory Defaults All Configuration Parameter values and Association information will be restored to factory default settings and excluded from the network step Setup Key LED Indication Status LED state will toggle for first 5 seconds Press and keep holding the PROG of being pressed button for no less than 10 seconds LED state will toggle again after the remaining 5 seconds Release the PROG button then triple click the PROG button within 2 seconds of step 1 LED will stay in previous ON or OFF stage Wireless Information Wireless range This device has an open air line of sight transmission distance of 30m which is compliant with th
2. Plug the lamp into the ZDS 200 Z Wave outlet Ensure that the loading is not exceeding 330 Watts Incandescent Lower than 330 Watts Incandescent or Resistive Load Press the button to turn the light ON OFF This button is a toggle switch press the button once to turn the light ON if the device is OFF and vice versa Pressing and holding the button will control the brightness Release the button when the desired brightness is attained This is also a toggle function press and hold the button to increase the brightness To decrease the brightness press and hold the button again Unplug the ZDS 200 from wall AC outlet Switch to SWITCH mode 8 Plug the lamp into the ZDS 200 Z Wave outlet Ensure that the loading does not exceed 330 Watts Incandescent or 500 Watts Resistive Load 9 Plug the ZDS 200 into a wall AC outlet 10 Press the button to turn the light ON OFF This button is a toggle switch press the button once to turn the light ON if the device is OFF and vice versa Z Wave setup and operations ZDS 200 can be configured as either a DIMMER or a SWITCH device and it will detect the operation mode using the position of the slide switch when powering on The ZDS 200 will stay in the selected operation mode after inclusion process and it will not respond to the slide switch selection after removing and re adding power If the user needs to change the operation mode the user must first perform
3. 50 Upper limit e g 85 Step 5 Set the maximum value to 85 e g 85 for parameter no 18 Max Step 6 Set the minimum value to 30 e g 30 for parameter no 19 Min Step 7 Keep this setting as the new default This way user will avoid flickering as a result from low or high outputs from this dimmer ZDS 200 also can act as a Switch with parameter no 17 18 and 19 The Switch function is required for inductive and capacitive devices unsuitable for dimming e g fluorescent lamps motors etc Support for Association Groups ZDS 200 supports 2 association groups A maximum of 1 4 node ID s non multi channel devices can be assigned to these association groups Association group_1 Association group_1 is used to report status changes such as AUTO report to gateway Max 1 node ID can be assigned to this association group ZDS 200 will trigger AUTO report function if the Dimmer or Switch status had been changed Association group_2 Dimmer mode After receiving a dimming command from a local switch or gateway e g 50 the ZDS 200 will automatically send out a related basic set command e g 50 to its associated group Switch mode After receiving a basic set command from a local switch or gateway On OxFF or Off 0x00 the ZDS 200 will automatically send out a related basic set command On OxFF or Off 0x00 to its associated group Max 4 node ID s can be assigned to this association group Please refer
4. SWITCH or DIMMER Mode Installation and Warning The incandescent light plugged into the Z Wave controlled outlet on this module must not exceed 330 watts DO NOT connect fluorescent light Plugging a non resistive load such as fluorescent light or a device with a motor into the Z Wave controlled outlet may result in damage to the ZDS 200 Dimming Switch Module and will void the warranty ZDS 200 will not block the lower outlet when plugged into upper outlet of a duplex wall receptacle Possible configurations are illustrated below Grounded AC outlet VS 2 pins AC power plug Grounded AC outlet VS 3 pins AC power plug Installed at upper AC outlet Installed at lower AC outlet Basic Operation ZDS 200 can be configured as either a DIMMER or a SWITCH device and it will detect the operation mode using the position of the slide switch when powering on Warning SWITCH Mode is required for inductive and capacitive devices unsuitable for dimming e g fluorescent lamps motors etc The dimming function will be disabled in this mode It could damage the ZDS 200 if connected to non dimmable load and perform dimming function in DIMMER mode The connected device can be turned ON in two ways 1 Manual control with the push button on the ZDS 200 2 Z Wave remote controller BW8330 BW8380 Z URC 550 ZRC 100 Manual ON OFF DIM function 1 Switch to DIMMER mode Push button
5. to your controller s instructions for information on whether or not it supports the Association function Operation diagram for Association Groups Association group_1 for Auto report to gateway y Association group_2 for dimmer and switch mode Z Wave Gateway Node ID A Z Wave devices Node ID ID B ID C ID D ID E No of Node ID in Association Group_1 1 max AUTO report No of Node ID in Association Group_2 4 max User can assign 0 to 4 node ID s from node ID B to ID E to its association group_2 Function example ZDS 200 will send out a control command to Association group_2 devices when ZDS 200 status had been changed ALL ON OFF functions Depending upon your primary controller the ZDS 200 can be set to respond to ALL ON and ALL OFF commands up to four different ways Some controllers may not be able to change the response from its default setting Please refer to your controller s instructions manual for information on whether or not it supports the configuration function and if so how to change these settings The four possible responses are It will respond to ALL ON and the ALLOFF commands default It will not respond to ALL ON and ALLOFF commands It will respond to the ALL OFF command but will not respond to the ALL ON command It will respond to the ALL ON command but will not respond to the ALLOFF command LED Indication Status LED Indication Status Device load turned on LED turns on
6. 400x224mm fold to80 x112mm Wireless Lighting Control ZDS 200NA Dimming Switch Module Dual mode USER MANUAL Introduction Thank you for choosing the ZDS 200 Dimming Switch Mini Module Z Wave control product ZDS 200 enabled product allows users to remotely control lighting home appliance and make home control easy with low installation and maintenance costs You may begin with a few Z Wave enabled devices as well as some of our products to build up a complete home automation system The ZDS 200 is a Z Wave enabled device and is fully compatible with any Z Wave enabled network It can be configured as either a DIMMER or a SWITCH device It allows remote Dimming or ON OFF control of specified lamps Each module is designed to act as a repeater which will re transmit a radio frequency RF signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination Glossary Devices lights and nodes are all terms to describe an individual Z Wave device These terms are all interchangeable when setting your Z Wave network A collection of Z Wave devices are controlled by prima secondary controllers operating on the same system A Z Wi network has its own unique ID code so that controllers not in network cannot control the system Inclusion Add a Z Wave device to the network Exclusion f Delete a Z Wave device from the network Network Wide Inclusion NW
7. I enables both end user friendly PI and Play like Z Wave network installation as well as professional Network Wide installation scenario where the inclusion process in terms of time Inclusion NWI will be reduced significantly NWI is a feature supported by a new frame type named Explorer which enables the Z Wave protocol to implement Adaptive Source Routing Association is used to organize nodes into different groups allowing the device to identify the nodes with a group identifier These groups can also be copied to other devices sco A scene is a collection of Z Wave devices configured to turn to a Device Light Node Z Wave Network Association specific level setting mode or perform an operation Scenes are usually activated by a controller timed event or a specific condition Key Features Supports Dual mode DIMMER and SWITCH Remote ON OFF DIM control via the Z Wave controller Manual ON OFF DIM control with the front panel push button Support Scene control Support Association Group and Auto Report switch status Supports Network Wide Inclusion NWI and Explore Frames High output power in DIMMER and SWITCH mode Over temperature protection Grounded 3 wire power connection for safety Does not block lower outlet when plugged into upper outlet of a duplex wall receptacle Product Overview A Status LED B ON OFF DIMMER PROG Push button C Z Wave controlled outlet D AC plug E Selective switch
8. an exclusion process The user will then switch to the target operation mode Dimmer or Switch and re include the ZDS 200 afterwards Warming SWITCH Mode is required for inductive and capacitive devices unsuitable for dimming e g fluorescent lamps motors etc The dimming function will be disabled in this mode It could damage the ZDS 200 if connected to non dimmable load and perform dimming function in DIMMER mode Switch On Off Dimmer Dimming Z Wave Remote Control Include or exclude the ZDS 200 from the existing Z Wave home control network with your primary controller Refer to your primary controller instructions to process the inclusion exclusion setup procedure When prompted by your primary controller triple click the PROG button within 1 second The unit will enter classical inclusion exclusion first then jump to NWI and after 5 seconds it will finally exit NWI mode automatically if there is no inclusion exclusion request The primary controller should indicate that the action was successful If the controller indicates the action was unsuccessful please repeat the procedure Once the unit is part of the network the same basic procedure is used to add the same unit to a group or scene Refer to the primary controller s instructions for more details for adding removing the unit to from the scene association All configuration parameter values will keep no changes after excluding the unit from t
9. d distributors or dealers during the applicable However there is no guarantee that interference will not occur in a particular Risk of burns warranty period This warranty gives you specific legal right and you may also installation If this equipment does cause harmful interference to radio or This unit never got qualified certificate to supply power for medical have other rights which vary in each country Please contact Customer Note Specifications subject to change without notice due to continuing product television reception which can be determined by turning the equipment off and instrument or any life support equipment Service at improvement on the user is encouraged to try to correct the interference by one or more of Do not dispose of electrical appliances and unsorted municipal waste use the following measures separate collection facilities Contact your local government for information Remotec Technology Limited Reorient or relocate the receiving antenna regarding the collection systems available E mail rtlsales remotec com hk Increase the separation between the equipment and receiver There are no user serviceable parts in this unit http Awww remotec com hk Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice Changes or modifications to this unit not expressly approved by the party responsible
10. d workmanship under normal use and service for Input voltage frequency 120Vac 60Hz 1 ee Sey ToL GANSE IMPNELENGE an as a period of one year from the original date of purchase from the distributor or FCC Information 2 this device must accept any interference including interference that may dealer RF operating distance up to 30m line of sight between the Wireless Controller cause undesired operation of the device and the elses 2 Wave receiver moduls at open area FOC ID 2ADPEDAOII This device complies with RSS 310 of Industry Canada Operation is subject DIMMER Max Incandescent load 330W 2 75A This device complies with Part 15 of the FCC Rules Operation is subject to to the condition et this device does not ea i cpa J REMOTEC shall not be liable for M tput the following two conditions Damages caused by defective devices for indirect incidental special ax Output power SWITCH Max Incandescent Load 330W 2 75A f ii i na i i ae 1 this device may not cause harmful interference and consequential or punitive damages including inter alia loss of profits Max Resistive Load 500W 4 16A H j 3 A ae Ww x 2 A k 2 this device must accept any interference received including interference arnings savings data loss of benefits claims by third parties and any property _ Detected internal temperature and cut off output once that may cause undesired operation To avoid the risk of electric shock the input prong comes wit
11. e Z Wave standards Performance can vary depending on the type of obstacles such as walls and furniture between the Z Wave devices Every Z Wave device set up in your network will act as a signal repeater allowing them to talk to each other and to find alternate routes in the case of reception dead spots caused by these obstacles Radio Frequency Limitations 1 Each wall or object i e refrigerator bookshelf large TV etc can reduce the maximum range by up to 20 30 Plasterboard and wooden walls will have less effect on the signal than concrete brick or tile 2 Wall mounted Z Wave devices will also suffer a loss of range if they are housed in metal junction boxes which could reduce the range by up to 20 30 Maintenance 1 Do not expose your unit to dust strong sunlight humidity high temperatures or mechanical shocks 2 Do not use corrosive or abrasive cleansers on your unit 3 Keep the unit dust free by wiping it with a soft dry cloth 4 Do not disassemble your unit it contains no user serviceable parts 10 11 12 13 14 Technical Specifications Certifications K Smaa i Warranty UL Listed SERA er n BW8130US 2DS 200NA This power unit is intended to be correctly orientated in a vertical or floor a aee enaa na masiy noes oo RSS standard s ONE YEAR LIMITED WARRANTY Remotec warrants this product to be free RF frequency 908 42MHz mount position sare m SUDJECNID i o ie ihe con nd from defects in materials an
12. for compliance could void the user authority to operate the equipment Printed in China F820 8130 0000 15 16 7 18
13. h a round damage or personal injuries arising from or related to the use of the device Over Temperature protection OTP triggered Remark Under over loading or Note di lug Th itch modul ly be pl d in to th Service trios t ide instructi duct temperature situation it will fail to start up ote f P grounding plug The switch module can only be plugged in to the power Service trips to provide instruction on product use This equipment has been tested and found to comply with the limits for a Class inlet with the grounding plug Please contact a qualified electrician to Shipping costs for replacement products B digital device pursuant to Part 15 of the FCC Rules These limits are replace the power inlet if it has no grounding inlet Do not change the plug Weight 125g designed to provide reasonable protection against harmful interference in a of this unit in any way This warranty is limited to the repair or replacement of this product only if the Storage Temperature 10 60 C residential installation This equipment generates uses and can radiate radio Do not modify the unit in any way purchase date cannot be substantiated the warranty period will begin on the frequency energy and if not installed and used in accordance with the Risk of fire date of manufacture as indicated on this product All warranty claims must be 7 ene instructions may cause harmful interference to radio communications Risk of electrical shock made to Remotec appointe
14. he network except for the parameter number 1 and Association information Z Wave Configuration Parameters Different user has different preferred settings of their thermostat you may use the below configuration parameters to change settings of corresponding functionality Activate Deactivate units to ALLON OFF 1 0x01 Parameter value 0 0x00 ALL ON is not active ALL OFF is not active 1 0x01 ALL ON is not active ALL OFF active 2 0x02 ALL ON is active ALL OFF is not active 255 0xFF ALL ON is active ALL OFF is active 7 Switch returns to the last position saved before Fs o aaaeeeaa 15 0x05 ooo Parameter value 0 0x00 Switch does not save the state after power failure device returns to off position ett Switch saves its state before power failure 0x01 Switch saves its state before power failure 100 S Switch Mode Double click option set to max brightness Parameter No No CE Pe aoe Double click function enabled Default Value _ 10x00 O Switch Mode oS O finitions Time of moving the Dimmer from 0 to max dimming values The ZDS 200 will implement the dimming duration if received this parameter value from controller gateway Otherwise the ZDS 200 will implement the local 17 0x11 Parameter value Dimmer Mode From 0 to 5 seconds Step size 1 second Default Value 3 0x03 Supported Switch Mode S O efinitions Maximum Dim
15. mer level 7 remap meetin Parameter No Heda oo aal 0x12 senres oo to 99 0x63 Switch Mode oo initions Minimum Dimmer level control refer to Figure 1 and Notes Below is the recommendation for different loads AC motors Parameter no 18 max 99 Parameter no 19 min gt 60 Fluorescent lamps fluorescent tubes non dimmable LED Parameter no 18 max 99 Parameter no 19 min 98 Remark 1 The maximum level must not be lower than the minimum level Switch Mode o 340x256mm fold to80 x112mm Brightness level lux 0 30 85 99 Z Wave dimming commands 0x00 Off OxFF On 0x01 1 to 0x63 99 Figure 1 Notes In order to avoid flickering and to support non dimmable devices the ZDS 200 provides parameter no 18 and 19 max and min dimmer level control If there is flickering the user can re configure the max and min level for the dimmer to skip the flickering at min or max level Example Procedure Step 1 Set the maximum value to 99 99 parameter no 18 Step 2 Set the minimum value to 1 1 parameter no 19 Step 3 Go back to normal operation mode for dimming Step 4 User is required to distinguish the flickering points by adjusting the dimming level on controller such as gateway or ZRC 100 User can adjust the brightness level upwards downwards from 50 until the flicking point is distinguished Brightness level Lower limit e g 30
Download Pdf Manuals
Related Search
Related Contents
MTH400 User Manual QuikEC3 release 0.01 13-04-07 QuikEC3 User's Guide TNC-EASYCONTROL V3.indd Agilent Technologies FS2334 Thermometer User Manual シールドプライマー 主剤 CH940-CH1000 Manual de servicio LevelOne 4-Port USB KVMwith USB HUB User`s Guide for Polycom HDX Room Systems, Version 2.5 Model: RC2123PT - Plastic Outdoor (Type 3R) Enclosure (Cópia de Manual SPAs rev9 9703) Copyright © All rights reserved.