1. e PATT Not Available 4 8 3 Button Description of the FC 812 M e CLR If press CLR button down and reset the management module FC 812 M some configuration will be set to factory setting as below IP address 192 168 0 140 subnet Mask 255 255 255 0 Gatewav 192 168 0 1 WEB type login users name user WEB tvpe password pass e PH Not Available 4 9 Port Description 4 9 1 Power input NOTE 220V For 220VAC power supply input One product can only For 5VDC power supply input support one kind of For 48VDC power supply input Power Supply 4 9 2 10 100M Ethernet port 10 100Mbps Half Full Duplex auto negotiate MDI MDI X auto detective F Fibridge F5 8513 Converter User Manual V1 5 4 9 3 NMS Not available 4 9 4 TXD amp RXD 1 8 1 8 channels of E1 TXD means OUT RXD means IN 5 Application Ethernet The F5 8513 is widelv used to connect two Ethernet its 16 384Mbps bandwidth makes it adapt to mostly application F5 8513 should be used in pairs and only support point to point application 6 Order Information 6 1 Module F5 4511 Ethernet to 1 8 E1 Protocol Converter Series 6 2 Part Number P N F5 8513A 10 100Mbps Ethernet to 8E1 Protocol Converter Standalone AG220V power supply F5 8513D 10 100Mbps Ethernet to 8E1 Protocol Converter Standalone DC 48V power supply F5 8513M 10 100Mbps Ethernet to 8E1 Protocol Converter Module Card FC 812
2. aj 1 Managed Port Connectors of Managed Module The upper RJ45 is MDI connector the below RJ45 is MDI X connector 2 E1 8 Ethernet port Connectors of F5 8513M Modules DB37 is for E1 ports Upper RJ45 is for Ethernet ports The below RJ45 is not available 3 Power Supply Input Connector F Fibridge F5 8513 Converter User Manual V1 5 The upper is for 220VAC the below is for 48VDC 4 DIP switch and R8485 They are reserved and are not available for current version The first 2 bit of the DIP switch should be reserved to ON 4 5 Sketch map of the F5 8513M Module Connector 12345678 dir SW5 ANA DIG REM PATT 123 45 67 8 Los 00000000 000 roeeeeeeeoe ERS Please refer to the standalone products to get the definition 4 6 Sketch map of the FC 812 M Module Management Module Connector 1 Buttons see 4 8 3 2 LEDs see 4 7 2 F Fibridge F5 8513 Converter User Manual V1 5 4 7 LED Description 4 7 1 LED Status Description of standalone Module products an ew Any of 4 buttons ANA Ca rE REM PATT is TEST Yellow pressed down ww hu aw Blink E1 E1 channel is transmitting data is E1 channel is transmitting data data Ethernet port link OK LNK Green OFF Ethemetpotinktoss on tenet port works on 100Mbps speed Ethernet port works on a eee speed ET 4 7 2 LED Status Description of Management Module FC 812 M oo Managed Module communicating with E u 8513M Modules Red Gree
3. 12 slot Chassis 6U height FP 8100A 100W AC220V Power Module for FC 812 chassis FP 8100D 100W DC 48V Power Module for FC 812 chassis We reserved the rights to modify this document without notice F Fibridge F5 8513 Converter User Manual V1 5 Beijing Fibridge Co LTD Address A402 Power Creative Building No 1 Shangdi East Road Haidian District Beijing 100085 PRC TEL 8610 58858988 58858519 FAX 8610 58858516 58858520 WEB http www fibridge com
4. Zj Fibridge F5 8513 10 100Mbps Ethernet to 8E1 Converter Standalone Module Chassis User Manual Version V1 5 Beijing Fibridge Co Ltd F Fibridge F5 8513 Converter User Manual V1 5 Content Te General is 2 2 FGAT Si E A E E E E E E E E EE ee 2 9 OPECHICIUON oe eera E a E EAE 2 3 1 EU ON i E E T T A 2 3 2 UNS NOT POTT ose A E A E 3 3 3 G d L A 3 3 4 ON rae cs sors A Sata cat rsh ae dase E E E 3 3 5 BU ON UN U i e AE A E 3 4 Installation Reference cc cccssceessneeeeseneeeesseeeeseeeeenseesenseeeens 3 4 1 Front Panel of the Standalone 00 00 00 ccc ccececeteeeseeeeeenseeeeeesseeeneens 3 4 2 Back Panel of the Standalone ss ennennnnenzznnnenznzzznnenznnznnnnn nanna 3 4 3 Front Channel of the Chassis ss nnennnnnzznnnnanzzznnnn nanna ann nn nanna 4 4 4 Back Channel of the Chassis ss enennnennenznnznnnzenznnnnane nanna nnnena nn 4 4 5 Sketch map of the F5 8513M Module sse eennnnnnenzzznnenzzzznnenzznnnnnzzz 5 4 6 Sketch map of the FC 812 M Module Management Module 5 4 7 LED DESCHPHON a e a 6 4 8 DIP Switch IE ON sea e N 7 4 9 Port DESCIIPtiON 0 0 0 0 ccc cccccsscecceesssseeeeeeesssseeceeessseeeeeeeensseeeeeeesssseeeeeess 8 5 PU CA OI aegis sce B a ae id 9 6 Order Information 0000 nnennnnnnnnnnnnnannena nn arana nanna n ran n ran ra nr 9 6 1 MOGUO oer en soecaanaesaneom aqaaceeseiaaeoa squares E E E E S 9 6 2 Part Number P
5. N ll ccccccccccccccceesssssseeeeccceeesssssseeeeeeeesesssseeeeeeeeeens 9 1 F Fibridge F5 8513 Converter User Manual V1 5 General F5 8513 is the most newly promoted product that can convert 100Base TX or 10Base T Ethernet to 8E1 signals and vice versa This protocol converter can extend the bandwidth to 16 384Mbps It not only provide completed indicators to show the status and alarm messages of the E1 line and Ethernet port but also support BER Stat of E1 and flow Stat of Ethernet port It is widely used in two LAN connecting remote monitor and video broadcasting 2 3 1 Features Compatible with ITU T G703 G704 and G823 Support 10Base T 100Base TX protocol 4096 pieces of MAC address list and with address filter function Ethernet port support MDI MDI X auto detect Enable any group of CH1 CH8 E1 channel to transmit the data at will Extend the bandwidth to 16 384Mbps when using 4E1 channels Support auto inspection of effective E1 channel without interruption of data transfer Automatically cut off the E1 Channel when it has LOS and AIS alarm and inform the remote end simultaneously Support Bi directional Local Loop 75ohm unbalanced E1 channel impedance Standalone and Chassis Module optional Chassis support SNMP based management Internal power supply AC160V 260V or DC 48V optional Specification E1 Port Bit rate 2 048 Mbps Line code HDB3 Standard Compatible with ITU T G703 G704 Impe
6. dance 5ohm Connector BNC Number of E1 8 Jitter Performance compatible with G 742 and G 823 Timing Mode Internal Clock or Recovered from E1 L Fibridge F5 8513 Converter User Manual V1 5 3 2 Ethernet Port Port Speed 10 100Mbps Auto Selection Auto negotiation with half full duplex Standard Compatible with IEEE802 3 802 3u Connector RJ45 MDI MDI X auto detect Number of Ports 1 or 3 or 4ports 3 3 Size e 483mm W X44mm H X 140mm D 3 4 Power e AC Power 100V 240V 0 4 0 2A 50 60 Hz e DC Power 48V 0 4A e Consumption Less than 3 Watts 3 5 Environment e Temperature O C 50OC e Humidity 30 90 4 Installation Reference 4 1 Front Panel of the Standalone ANA DIG REM PATT 12 3 4 5 6 7 8 LNK WTX PWR OOOO WH seccccesecee oe my ON ee e oO O SPD WRX TEST 12345678 CRC 0000 1 2 3 4 1 Buttons see 4 8 1 2 DIP Switches see 4 8 1 3 LEDs see 4 7 1 4 Power Switch 4 2 Back Panel of the Standalone 220VAC ASVD SVDC 8VDC 10 100M NMS oF IL 3 4 5 1 2 1 Power Supply Input 2 Ethernet Port 3 NMS N A 4 El Channel 5 Protecting GND L Fibridge F5 8513 Converter User Manual V1 5 4 3 Front Channel of the Chassis 0 01 PWR PWR e T o 1 Managed Module 2 12 pieces of F5 8513M Modules 3 2 pieces of Power Supply Modules 4 4 Back Channel of the Chassis MIMLI a l 4E1 idi T 5 8El nanii Pd a 2 1
7. n ON Managed Module is idle or Power isot Managed Module is ie or Poweris ofk is idle or Power is off w Ethernet port link OK LNK Green Ethernet port link Loss OFF Ethernet port works on 10Mbps speed DATA Yelow JON l Ethernet is transmitting or receiving data Ethernet is transmitting or receiving data is transmitting or receiving data ki Power Module is communicating with Managed Card ore kanen Module isnt communicating with fore Pome Card ON Module 1 to 12 is communicating with Managed Card LO L11 Green Module 1 to 12 isnt communicating with OFF Managed Card Green L Fibridge F5 8513 Converter User Manual V1 5 L12 L15 Not Available 4 8 DIP Switch amp Button 4 8 1 DIP Switch Setting of F5 8513 and F5 8513M Bit eseription CRC alarm limitation setting ON ON no setting OFF ON 1x10 4 ON OFF 1x10 5 OFF OFF 1x10 6 default _ 2 OFF gt ON or ON gt OFF change will reset local device O4 OFF gt ON or ON gt OFF change will reset remote device 4 8 2 Button Description of the F5 8513 and F5 8513M ANA Local loop of E1 used to test if local device and connect wire is normal LH PULLU 1 e lt e A O o jab e o e DIG Not Available e REM E1 Loop from local to remote side Z Fibridge F5 8513 Converter User Manual V1 5 LHS fr emp I ore Q 8 5 lt es q g O as o O O