Home

Destroyer X250 Punisher X250 user manual

image

Contents

1. 10 1 controller 0 stand alone DIP Switch Setting 9 1 1 channel 0 5 6 channel DMX 8 0 0 0 0 1 1 1 1 0 OFF 7 0 0 1 1 0 0 1 1 1 ON 6 0 1 0 1 0 1 0 1 1 2 3 4 5 0 0 0 0 0 32 64 96 128 160 192 224 1 0 0 0 0 1 33 65 97 129 161 193 225 0 1 0 0 0 2 34 66 98 130 162 194 226 1 1 0 0 0 3 35 67 99 131 163 195 227 0 0 1 0 0 4 36 68 100 132 164 196 228 1 0 1 0 0 5 37 69 101 133 165 197 229 0 1 1 0 0 6 38 70 102 134 166 198 230 1 1 1 0 0 7 39 71 103 135 167 199 231 0 0 0 1 0 8 40 72 104 136 168 200 232 1 0 0 1 0 9 41 73 105 137 169 201 233 0 1 0 1 0 10 42 74 106 138 170 202 234 1 1 0 1 0 11 43 715 107 139 171 203 235 0 0 1 1 0 12 44 76 108 140 172 204 236 1 0 1 1 0 13 45 77 109 141 173 205 237 0 1 1 1 0 14 46 78 110 142 174 206 238 1 1 1 1 0 15 47 79 111 143 175 207 239 0 0 0 0 1 16 48 80 112 144 176 208 240 1 0 0 0 1 17 49 81 113 145 177 209 241 0 1 0 0 1 18 50 82 114 146 178 f 210 242 1 1 0 0 1 19 51 83 115 147 179 f 211 243 0 0 1 0 1 20 OZ 84 116 148 180 212 244 1 0 1 0 1 21 53 85 117 149 181 213 245 0 1 1 0 1 22 54 86 118 150 182 214 246 1 1 1 0 1 23 55 87 119 151 183 215 247 0 0 0 1 1 24 56 88 120 152 184 216 248 1 0 0 1 1 25 57 89 121 153 185 217 249 0 1 0 1 1 26 58 90 122 154 186 218 250 1 1 0 1 1 27 59 91 123 155 187 219 251 0 0 1 1 1 28 60 92 124 156 188 220 252 1 0 1 1 1 20 6l 93 125 157 189 221 293 0 1 1 1 1 30 62 94 126 15
2. 110 125 V 50 60Hz Primary fuse 230 245Vmodel 2 5 AT 250 V P N 05020010 Primary fuse 110 120Vmodel 5 0 AT 250 V P N 05020018 INSTALLATION Minimum distancetocombustiblematerials 0 1 m 4 in Minimum distancetoill uminatedsurfaces 0 3 m 12 in Minimum clearancearoundfanandairvents 0 1 m 4 in ACCESSORIES M E 1 controller EU ln aradaki Shia bo 90718000 ME controller US Seve stilleriyle la im kaale os 90718100 50 hour lamp halogen EHJ 24V250NW 97000105 300 hour lamp halogen EVC M33 24V0250W 97000103 G clamp 91602003 Halt Couplers 8 aaa mall silimi ia kllela nsl 91602005 Martin Professional A S Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 www martin dk
3. 8 190 222 254 1 1 1 1 1 31 63 95 127 159 191 223 255 Controller Operation Il STAND ALONE OPERATION Important 12 STAND ALONE If the unit does not receive control data it automatically goes into stand alone mode and performs a random sequence triggered by sounds picked up by the built in microphone STAND ALONE MASTER SLAVE DESTROYER ONLY If you have two or more Destroyers this feature allows you to operate all the units in synchronization You must assign one but only one unit to be master by setting DIP switch 10 OFF The unit will then be sending DMX signals via its XLR in and output connectors that correspond to what it is doing itself You can then connect up to 32 slaves which will all perform exactly the same when set to DMX address 1 To prevent damage to the electronic circuitry one and only one fixture may be set as master DIP switch 10 OFF Disconnect all fixtures from AC power Female On the master unit set DIP switch 10 OFF Termination Plug On all slave units set DIP switch 1 and 10 ON Female XLR Insert a 120Q female XLR termination plug P N 91613018 in the DMX input socket of the master 1 unit A 120 Connect the DMX output of the master unit to the input of one of the slaves using a XLR XLR cable Continue the link this way always connecting P N 91613018 output to input daisy chain until all slaves are linked together Finally insert a 120Q male XLR termina
4. Destroyer X250 Punisher X250 user manual A Mart n dimensions in millimeters 340 Lamp access Focus adjustment 1996 1999 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000035 Rev B a s7 NTRODUCTION The Destroyer X250 and Punisher X250 developed and manufactured by Martin Professional are aggressive disco lighting effects using a powerful 250W halogen lamp With a motorized parabolic reflector and gobo wheel they produce a myriad of turning beams that change color and pattern on demand There is a flash effect for strobe like animation and on the Punisher a motor driven shake effect Unlike most fixtures of this type the effects of the Destroyer and Punisher are programmable from any standard DMX 512 controller using a single or multi channel protocol Alternatively the Destroyer and Punisher can be directly triggered from a music source as stand alone units In addition the Destroyer can run several units in master slave configuration FEATURES Multiple rotating beams 12 pattern gobo wheel 7 with color and 5 white 24 V 250 W halogen lamp Dichroic colors Adjus
5. ed on a serial link Terminate the link by inserting a male termination plug P N 91613017 into the data output of the last fixture A termination plug is simply an XLR connector with a 120 ohm 0 25 W resistor soldered across pins 2 and 3 5 pin to 3 pin 3 pin to 5 pin 3 pin to 3 pin Male Adaptor Adaptor Phase Reversing Termination Plug Adaptor Male Female Male Female Male Female Male XLR 1 1 1 1 1 1 1 2 2 2 2 2 2 2 3 3 3 3 go lt 3 3 120 4 4 5 5 P N 11820005 P N 11820004 P N 11820006 P N 91613017 Controller Operation 9 Important 1 2 3 4 5 10 ADDRESS AND MODE SETTINGS On the rear of the unit is a 10 way DIP switch with the following functions Switch ON OFF 1 8 DMX address 1 255 9 1 channel DMX Multi channel DMX 5 6 10 Slave DMX reception Master DMX transmission Destroyer only DMX MODE SETTING The Destroyer Punisher has two DMX modes a 1 channel mode and a multi channel mode that requires 5 channels for the Destroyer and 6 channels for the Punisher The 1 channel mode is simpler and saves channels on your controller In this mode the unit becomes more aggressive the higher you set the fader The Martin MC 1 controller is specially designed to operate the Destroy Punisher and other Martin products is 1 channel mode When using the Destroyer X250 and Punisher X250 with the MC 1 the address see below must be set to DMX c
6. hannel 1 For full control of each effect use the multi channel mode The functions of each mode are described in appendix a Use DIP switch 9 to select the DMX mode Flip the pin ON for 1 channel operation of OFF for multi channel operation ADDRESS SETTING Use the first 8 DIP switches to set the DMX address the first DMX channel on which the Destroyer Punisher responds to the controller to any value between 1 and 255 The address is the sum of the values for each individual DIP switch that is ON DIP switch 10 must be flipped ON when using the Destroyer or Punisher with a controller Otherwise both the unit and the controller will transmit DMX signals and damage to one or both devices may occur Select an address for the fixture on your controller When using the MC 1 controller the address must be DMX channel 1 Look up the DIP switch setting for the address on page 11 Set pins 1 through 8 to the ON 1 or OFF 0 position as listed in the table Set pin 9 to ON for 1 channel operation or OFF for multi channel operation Set pin 10 to the ON position Controller Operation ADDRESS TABLE Locate the channel in the table below Follow the row to the left to find the settings for pins 1 to 5 follow the column to the top to find the settings for pins 6 to 8 Pin 9 selects DMX mode Pin 10 selects controller or stand alone operation and stand alone master slave on the Destroyer
7. ified type and rating e Keep all combustible materials at least 0 1 meters 4 inches away from the fixture Keep flammable materials well away from the fixture Do not illuminate surfaces within 0 3 meters 12 inches of the fixture e Provide a minimum clearance of 0 1 meters 4 inches around fans and air vents Replace the lamp if it becomes defective or worn out When replacing the lamp allow the fixture to cool for at least 15 minutes before opening the fixture or removing the lamp Protect your hands and eyes with gloves and safety glasses e Never place filters or other materials over the lens The thumbscrews holding the lamp socket assembly reach temperatures up to 120 C 250 F Allow the fixture to cool for 15 minutes before handling e Do not operate the fixture if the ambient temperature Ta exceeds 40 C 104 F 4 Safety Information To protect yourself and others from injury due to falls e When suspending the fixture above ground level verify that the structure can hold at least 10 times the weight of all installed devices e Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a safety cable e Block access below the work area whenever installing or removing the fixture Safety Information 5 SETUP The package includes the following items Destroyer or Punisher TEC mains cable Mounting bracket and hardware U
8. ing transit and must be removed to enable the shake effect Remove the top cover from the unit by unscrewing the 4 Phillips screws that hold it in place Locate the parabolic mirror assembly in the center of the unit and unscrew the 4 RED Phillips screws holding the transport plate Remove the plate Reassemble the unit FITTING THE MOUNTING BRACKET Fit the supplied mounting bracket using the plastic spacers star washers and thumbscrews The star washer must be placed between the bracket and the plastic spacer RIGGING THE UNIT Verify that the structure can support at least 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc If hanging the fixture with a rigging clamp verify that the clamp is undamaged and is designed for the fixture s weight Bolt the clamp securely to the bracket with a grade 8 8 minimum M12 bolt and lock nut or as recommended by the clamp manufacturer through the clamp hole in the mounting bracket If permanently installing the fixture verify that the hardware not included and mounting surface can bear at least 10 times the fixture s weight The four small holes and the clamp hole in the mounting bracket may be used for attachment Working from a stable platform clamp or fasten the fixture to the structure Install a safety cable that can hold at least 10 times the weight of the fixture through over the support and mounting bracket Loosen the thumbsc
9. it No lamp or lamp blown Install or replace lamp Unit appears to be completely dead no reset when switching on Mains fuse blown Replace fuse located in power input socket PCB fuse blown Replace PCB fuse Lamp is cutting out intermittently Room temperature is too high Reduce room temperature Fan speed is reduced due to fan covered by dirt and dust Clean fan and air vents Incorrect voltage setting Troubleshooting Check voltage setting Correct if necessary 230 245V 110 120V 15 SPECIFICATIONS PHYSICAL Size LxWxH 340 x 265 x 303 mm 13 4 x 10 4 x 11 9 Weight Acnis chains ee ees Ned sien hae aa 7 kg 15 4 lbs THERMAL Maximum ambient temperature 1 40 C 104 F Maximum surfacetemperature 120 C 250 F CONTROL AND PROGRAMMING Datapin out pin 1 shield pin 2 cold pin 3 hot Controlprotocol USITT DMX 512 1990 DMX channels Destroyer t icc cecesceessecstececsepnesetoscceconronsooegscoatondonsotesicoseoneote 1 5 DMX channels Punisher m arka a 1 6 AC POWER Max powerandcurrent 270 W 1 2 A 230 V 270 W 2 3 A 120 V Inputsocket 3 prong IEC male socket Input 230 245 Vmodel 230 245 V 50 60Hz Toput 110 120Vmodel
10. lue Effect 0 50 Blackout 51 101 Slow random action 1 102 152 Medium random action 153 203 Fast random action 204 255 Random speed and action 14 DMX Protocol TROUBLESHOOTING Problem Probable cause s Suggested remedy None of the units respond to the controller The controller is disconnected from the DMX link Connect controller Use of incorrect cable between the controller and the first unit on the DMX link Check pin out of DMX controller against Destroyer Punisher and ensure that signal goes to signal and signal goes to signal One or more of the units does not respond to the controller or respond erratically Bad DMX link connection Check connections cables in the DMX link and correct accordingly DMX link not terminated with termination plug Insert termination plug in the last unit on the DMX link Incorrectly addressing DIP switch setting of the unit Ensure that all units are addressed in compliance with the controller configuration Unit not powered on Power on unit One or more units are set to master i e DIP switch 10 OFF Set DIP switch 10 ON One of the units is defective and disturbs the data transmission on the link By pass one unit at a time until normal operation is regained Do this by unplugging the XLR in and out connectors and then connect them directly together No light emission from un
11. rews tilt the fixture to the desired angle and retighten Verify that the fixture is at least 0 3 meters 12 in from the surface to be illuminated and at least 0 1 meters 4 in from any combustible materials Verify that the clearance around the air vents is at least 0 1 meters 4 in Setup CONTROLLER OPERATION CONNECTING THE DATA LINK A reliable data connection begins with the right cable Standard microphone cable cannot transmit DMX data reliably over long runs For best results use cable specifically designed for RS 485 applications The XLR data sockets are wired with pin 1 to ground pin 2 to signal cold and pin 3 to signal hot This is the standard pin assignment for DMX devices One or more adaptor cables may be required to connect the fixture to the controller and or other lights as many devices have 5 pin connectors and others may have reversed signal polarity Connect a data cable to the controller s output If controller has a 5 pin output use a 5 pin male to 3 pin female adaptor cable P N 11820005 Lead the data cable from the controller to the first fixture Plug the cable into the fixture s data input Connect the output of the fixture closest to the controller to the input of the next fixture If connecting two fixtures with reversed polarity on pins 2 and 3 insert a phase reversing cable between the two fixtures Continue connecting fixtures output to input Up to 32 devices may be connect
12. s three wires Connect the BROWN wire to the LIVE pin Connect the BLUE wire to the NEUTRAL pin Connect the YELLOW GREEN wire to the EARTH pin ADJUSTING THE VOLTAGE SETTING The voltage setting on the Destroyer Punisher shall match the local power supply The factory setting is printed on the serial number label on rear of the unit If the setting does not match the local power supply rewire the unit as follows To prevent damage the RED wire must be connected to an outside pin as shown Disconnect the fixture from AC power Remove the top cover from the unit by unscrewing the 4 screws that hold it in place Locate and disconnect the plug with red yellow and blue wires at the top right corner of the printed circuit board as seen from the back of the unit To change to 230 V AC EU version or 110 V AC US version flip and move the plug right so that the red wire connects to the pin closest to the edge To change to 245 V AC EU version or 120 V AC US version flip and move the plug eft so that the red wire connects to the pin furthest from the edge Replace the top cover before applying power 110 V US 120 V US 230 V EU 245 V EU lt z panii Q Power setting plug as seen from rear l pal Setup 7 REMOVING THE TRANSPORT SECURITY PLATE PUNISHER ONLY Before first operating the Punisher you need to remove the transport security plate inside the unit This plate holds the mirror assembly dur
13. ser manual Before starting to operate the unit you need to Install the halogen lamp not included Fit a mains plug Check voltage setting Fit the mounting bracket Rig the unit in its permanent site WARNING Always disconnect the unit from AC power before performing any installation or service procedure INSTALLING THE LAMP See the specifications on page 16 for lamps that may be used in the Destroyer X250 and Punisher X250 Do not install any other lamp Warning Allow the unit to cool for 15 minutes before handling 1 Remove the 2 screws from the lamp access plate on the bottom of the unit N Loosen the thumbscrew and pull back on the lamp socket reflector assembly until the assembly is free of its mounting plate Remove the lamp assembly 3 Hold the new lamp in a cloth to avoid contaminating it with oils from your fingers Press it squarely into the socket 4 Hold the lamp assembly by the socket end with the thumbscrew up Slide the thumbscrew into the notch on the mounting plate Align the holes in the assembly with the guide screws on the mounting plate and press the lamp assembly flush against the mounting plate Tighten the thumbscrew 5 Replace the lamp access cover 6 Setup Important FITTING THE MAINS PLUG The Destroyer Punisher is delivered from the factory without a plug on the mains cable You will have to fit a plug that conforms to your local mains outlet The double insulated mains cable contain
14. table focus Sound activated beam rotation and color pattern change Sound activated shake effect Punisher only Built in microphone with automatic sensitivity adjustment Multi or single channel DMX control Master slave configuration Destroyer only Stepmotor drive Adjustable mounting bracket Introduction 3 SAFETY NFORMATION Warning This product is not for household use It presents risks of lethal or severe injury due to fire and heat electric shock and falls Read this manual before powering or installing the fixture follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact a Martin distributor for assistance To protect yourself and others from electric shock e Disconnect the fixture from AC power before removing or installing the lamp fuses or any part and when not in use e Always ground earth the fixture electrically e Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Do not expose the fixture to rain or moisture e Refer all service to a qualified technician e Never operate the fixture with missing or damaged lenses and or covers To protect yourself and others from burns and fire e Never attempt to bypass the thermostatic switch or fuses Always replace defective fuses with ones of the spec
15. tion plug P N 91613017 in the free output socket of the last unit on the link Apply power first to the master and then to the slave fixtures Stand Alone Operation DMX PROTOCOL MULTI CHANNEL MODE DMX Channel DMX Value Description Lamp ON OFF 1 0 11 Lamp OFF 12 193 Lamp ON 194 255 Gobo strobe slow fast Trigger Mode 2 0 11 Off 12 127 Music triggered 128 255 Controller triggered triggers when DMX level crosses 195 Parabol Speed The rotation time is equal to the trigger decay if trigger mode is set to music or controller 3 0 91 Rotation CW fast gt slow 92 98 Stop 99 189 Rotation CCW slow fast 190 231 Random CW CCW slow music controller triggered 232 255 Random CW CCW fast music controller triggered Trigger Decay 4 0 4 Oseconds 5 252 0 2 to 9 9 seconds 253 255 Random music controller triggered DMX Protocol 13 DMX Channel DMX Value Description Color Gobo Wheel 0 5 Blackout 6 20 Position 1 21 36 Position2 37 52 Position3 53 68 Position4 69 84 Position 5 85 100 Position 6 2 101 116 Position 7 117 132 Position 8 133 148 Position 9 149 164 Position 10 165 180 Position 11 181 196 Position 12 197 244 No effect 245 255 Random music controller triggered Shake Punisher only 0 4 Off c 5 252 Slow fast 253 255 Random music controller triggered SINGLE CHANNEL MODE Channel DMX Va

Download Pdf Manuals

image

Related Search

Related Contents

  イニ二『コ ・具ー黒明器具  Philips Sonicare DiamondClean Standard sonic toothbrush heads HX6062    Mode d`emploi laverie  Operating Instructions Hotmelt Applicator Please read carefully  Samsung CC03 User Manual    voir le descriptif détaillé du parcours d`automne 2015.  Manual do Utilizador do S300 Series  

Copyright © All rights reserved.
Failed to retrieve file