MS 300 SERIES METER

image

Contents

1. Double insulation Pollution level 2 Installation category III according to CEI 664 Allocated voltage 600V 5 4 Electromagnetic compatibility Emission EN 61326 1 2006 Immunity EN 61326 1 2006 Maximum influence in the presence of conducted radio frequencies 3 times the accuracy class if the length of the measured circuit is gt 3m 6 SUPPLY To order MS304 Delivery wattmeter user s manual 7 MAINTENANCE Only use the specified spare parts for maintenance The manufacturer shall not be held liable for any incident occurring following repairs carried out by a party other than its after sales service or approved repairers 7 1 Changing the fuses Opening the wattmeter Open the device by removing the black over Use the same type of fuses to ensure the safety of users and of the device Fuse 1 A 500V 7 2 Storage If the wattmeter is not used for a period of over 60 days remove the battery and store it separately For a shorter period avoid leaving the wattmeter in ohmmeter position There is a risk of premature battery wear if the tips come into contact with 1t 7 3 Cleaning The wattmeter must be disconnected from all electricity sources To clean the casing use a cloth dampened with soapy water Wipe over with a damp cloth Dry quickly with a dry cloth or forced air
2. Before any measurement ensure correct positioning of the leads on the wattmeter and of the switch When the value range of a measurement is not known place the switch at the highest caliber and then gradually reduce it until the appropriate caliber is achieved the reading should preferably be in the upper 2 3 of the range The leads must be disconnected to open the lower half of the meter case Never connect to the circuit to be measured if the casing is not properly closed CONTENTS DESCRIPTION P 2 BREPEPRERN CEA GUT BT ENLO qr Stt o elus E die EODD C O a FMEA SUREMENT c 3 74 NER a eats ease M Ya on o a II A A II IN NL i 1 DESCRIPTION The MS304 wattmeter is for everyday use by electricity professionals It offers the following functions Wattmeter power measurement DC and AC 1 1 Safety terminals 4mm COM common terminal receiving the black lead 1 A for Apc and Aac calibers 2 COM common terminal receiving the black lead 3 V for voltage 4 1 2 5 range dial 5 1 black with anti parallax mirror for the Ppc and Pac 1 3 Range selection switch 6 MS304 WATTMETER 2 REFERENCE CONDITIONS Temperature 23 C 2 C Humidity 45 RH 5 Position horizontal 2 Ensure that the po
3. MS 300 SERIES METER USER S MANUAL Safety Meaning of symbol zx CAUTION Please consult the operating instructions before using the device In these operating instructions failure to follow or carry out instructions preceded by this symbol may result in personal injury or damage to the device and the installations Meaning of symbol This appliance is protected by double insulation or reinforced insulation It does not have to be connected to an earth protection terminal for electrical safety Thank you for purchasing this MS304 wattmeter To obtain the best service from your unit Read these operating instructions carefully Comply with the precautions for use 2 PRECAUTIONS FOR USE O Never use on a voltage network over 600V with respect to the earth connection This voltage surge category III wattmeter complies with stringent reliability and availability requirements corresponding to fixed industrial and domestic installations see IEC 664 1 Do not use on alternative and continuous voltages gt 600V Indoor use in environments with a maximum pollution level of 2 EN 50419 2006 temperature of 10 C to 50 C and relative humidity below 90 Respect the value and type of the fuses to avoid damaging the instrument and canceling the warranty O Fuse 1A 500V Use accessories corresponding to safety standards EN 61010 1 2001 with 600V minimum voltage and surge category III
4. inter 1s at zero before starting any measurements Zero adjustment open the device Mechanical zero adjustment is carried out by turning the screw on the back of the null meter Ensure that the switch is correctly positioned When an estimated measurement is unknown place the switch at the highest caliber and then gradually reduce it until the appropriate caliber is achieved the reading should preferably be in the upper 2 3 of the range 3 SPECIFICATIONS Connect the leads to the wattmeter be careful of switch position see below and connect to the circuit to be controlled When an estimated measurement is unknown place the switch at the highest caliber and then gradually reduce it until the appropriate caliber is achieved To obtain power in W multiply the appropriate range value by the reading coefficient indicated in the table Range V AC DC Range 0 5 A LA 0 5 A LA 0 5 A LA 0 5 A LA A AC DC 120 V 240 V 480 V Reading 0 25 0 5 0 5 1 1 2 2 4 coefficient Internal 30 kQ 60 kQ 60 kO 120 kQ 120 kQ 240 kO 240 kO 480 kQ rome Accuracy Accuracy 1 1 on AC 2 5 on DC Admissible 120 V 2 120 V 2 380 V 2 600 V 2 Overload 4 240 V 3 400 V 3 600 V 3 800 V 3 1 In 9o of end of range 2 2 A on the current ranges for a maximum measurement time of 2 to 3 minutes 3 10 In on current ranges for a maximum measurement time of 5 seconds 4 The current or voltage circuit can withstand permanent over
5. loads of 25 4 MEASUREMENTS 4 1 Measurement time About 2 5 seconds 4 2 Single phase measurements Place the switch on the range corresponding to the voltage and the current of the circuit on which you want to make the measurement Connected the MS304 as shown in the diagram O Read the deflection of the needle on the measurement scale read the value in such a way that the reflection of the needle on the anti parallax mirror is hidden Apply the coefficient corresponding to the voltage and the current indicated by the switch Example o 120Vx0 5A 60W The coefficient 0 5 corresponds to the 60W on the table The result in Watts is therefore Number of division of the reading x 0 5 4 3 Measurement of vars on 3 phase 3 wire balanced Connected the MS404 as shown in the diagram In addition to the coefficient corresponding to the position of the switch apply the coefficient 3 for 3 phase See preceding example for single phase Q var 3 x number of divisions read x 0 5 V1 Source V3 V2 VI Source Use Use 5 GENERAL CHARACTERISTICS 5 1 Dimensions and weight Dimensions 165x105x50mm Weight 670g 5 2 Maximum climatic conditions Temperature use 10 C to 50 C storage 30 C to 70 C Relative humidity use lt 80 HR Altitude use lt 2000m 5 3 Compliance with international standards Electrical safety EN 61010 1 2001 CEI 1010 1 EN61010 NF C 42020 VDE 0411

Download Pdf Manuals

image

Related Search

Related Contents

EnGenius SN-258 PLUS  ワイヤレススイッチ クイック インストレーション ガイド  The Parallel C Preprocessor* - Hindawi Publishing Corporation  Logica 230 Logica 230 RI  Digital switching Components from Mastervolt - Y  RKW-404A-SV  Dayton 5S1792 User's Manual  ベルの色 を確 - Garage  PREGÃO ELETRÔNICO Nº. 010/2011 PROCESSO Nº  SPEEDLINK Rica  