Home
ChromaFlash™ Plant Chromatin Extraction Kit
Contents
1. ChromaFlash Plant Chromatin Extraction Kit Base Catalog P 2022 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE Uses The ChromaFlash Plant Chromatin Extraction Kit is suitable for isolating chromatin or DNA protein complex from plants in a simple and rapid format Chromatin prepared by using this kit can be used in a variety of chromatin immunoprecipitation methods It is the optimal method for preparing chromatin required by Epigentek s one hour ChIP procedure using the ChromaFlash One Step ChIP Kit P 2025 or the ChromaFlash Magnetic ChIP Kit P 2026 The isolated chromatin can also be used in other chromatin related applications such as in vitro protein DNA binding assays or nuclear enzyme assays Starting Material and Input amount Starting materials can include various types of plant tissue such as flowers leaves and young seedlings The amount of tissue for each preparation can be 100 mg to 1 g A total of 50 standard extractions can be performed with this kit use 200 mg of tissue per extraction Yield of chromatin is approximately 0 5 to 2 ug per 200 mg of tissue depending on the tissue type Precautions To avoid cross contamination carefully pipette the sample or solution into the strip wells Use aerosol barrier pipette tips and always change pipette tips between liquid transfers Wear gloves throughout the entire procedure In case of contact between gloves and sample change gloves immediately 110 Bi Coun
2. in living cells by combining it with PCR ChIP PCR microarray ChIP chip or sequencing ChIP Seq techniques When performing ChIP chromatin or DNA protein complex in plant tissues need to be first isolated in an efficient manner However the existing methods used for plant chromatin preparation are inconvenient and time consuming The ChromaFlash Plant Chromatin Extraction Kit addresses these issues by introducing the following features e Extremely fast procedure the entire procedure from cell tissue sample to ready to use chromatin is less than 2 hours e Convenient and flexible the kit is suitable for preparing both native chromatin and cross linked chromatin from monolayer or Suspension cells or from tissues e Unsheared chromatin makes it customizable for various analysis workflows that require either intact or fragmented chromatin including ChIP in vitro protein DNA interaction analysis nuclear enzyme assay etc 110 Bi County Blvd Ste 122 Farmingdale NY 11735 Page 3 Tel 1 877 374 4368 m Fax 1 718 484 3956 m E mail info epigentek com m Web www epigentek com Printed 2013 12 13 Epigentek Group Inc All rights reserved Products are for research use only PRINCIPLE amp PROCEDURE The ChromaFlash Plant Chromatin Extraction Kit contains all the reagents required for carrying out a successful chromatin extraction directly from plant tissues Cell membranes of the sample with or without cross linking are
3. broken down using the provided lysis buffer Chromatin or DNA protein complex is then extracted with the extraction buffer The extracted chromatin can then be diluted with chromatin buffer and stored at the appropriate temperature Start with flowers leaves or seedlings 20 18 l 16 14 a 12 Lyse sample with lysis buffer a 10 s J 4 Extract chromatin with 9 extraction butter rh gc Trim ethyl H3 K27 Obtain isolated chromatin ChIP analysis of tri methyl H3 K27 enriched in AGAMOUS gene with chromatin extract prepared Schematic procedure of the ChromaFlash from 2 week old icu2 1 icu2 1 seedlings using the Plant Chromatin Extraction Kit ChromaFlash Plant Chromatin Extraction Kit Assay Protocol For the best results please read the protocol in its entirety prior to starting your experiment Starting Materials Input Amount Harvest 0 2 to 1 g of plant tissue flowers leaves or young seedlings after growth in soil or in vitro in a 50 ml Falcon tube Expected Yield 5 preparations can be performed when 1 g of tissue is used 0 2 g per extraction 1 Preparation of Working Buffers and Solutions a Prepare Working Lysis Buffer by adding 1 ml of 5X Lysis Buffer to every 4 ml of distilled water Then add 4 ul of BME to every 10 ml of diluted Working Lysis Buffer 1X b Prepare Working Extraction Buffer A by adding 1 ul of BME to every 1 ml of Extraction Buffer A c Prepare Working Extraction Buffer B by addin
4. g 1 ul of BME to every 1 ml of Extraction Buffer B 110 Bi County Blvd Ste 122 Farmingdale NY 11735 Page A Tel 1 877 374 4368 m Fax 1 718 484 3956 m E mail info epigentek com m Web www epigentek com Printed 2013 12 13 Epigentek Group Inc All rights reserved Products are for research use only d Prepare Working Extraction Buffer C by adding 1 ul of Protease Inhibitor Cocktail for every 1 ml of Extraction Buffer C Note Put all working buffers on ice before use 2 Cell Collection and Cross Linking Note For tissues that are not cross linked skip this section and go directly to step 3a of Tissue Lysis and Chromatin Extraction Gently rinse tissue with 20 ml of deionized water 2 times Remove as much water as possible from the tissue Place the tissue into a 50 ml conical tube Then add 5 ml of 1 0 formaldehyde solution per 200 mg of tissue into the 50 ml conical tube Stuff the top of the 50 ml conical tube containing the formaldehyde soaked tissue with nylon mesh to keep the tissue immersed during vacuum infiltration and to aid later rinse steps Then poke several needle sized holes in the cap of the conical tube and screw the cap on Vacuum infiltrate the tissue for 10 minutes in a desiccator attached to a vacuum pump The formaldehyde solution should boil Quench cross linking by adding 0 3 ml of 2M glycine per 5 ml of 1 0 formaldehyde solution final glycine concentration is 0 125M Then continue vacuu
5. ich is extraction reagents 6 months from the time of shipment Expired reagents may cause an inefficient extraction Incorrect temperature and or Ensure the incubation times and insufficient time during temperatures described in the protocol are extraction followed correctly Chromatin Improper sample storage Chromatin sample should be stored at 80 C degradation 3 6 months Avoid repeated freeze thawing cycles RELATED PRODUCTS Chromatin Shearing and Cleanup P 1006 DNA Concentrator Kit Sonication Instruments EQC 1000 EpiSonic Multi Functional Bioprocessor 1000 ChIP Reaction P 2025 ChromaFlash One Step ChIP Kit P 2026 ChromaFlash Magnetic ChIP kit PCR Analysis P 1029 EpiQuik Quantitative PCR Fast Kit 110 Bi County Blvd Ste 122 Farmingdale NY 11735 Page 6 Tel 1 877 374 4368 m Fax 1 718 484 3956 m E mail info epigentek com m Web www epigentek com j i 13 12 1 Epigentek Group Inc All rights reserved Products are for research use only SAAE a i
6. les at 20 seconds per cycle to increase chromatin extraction Allow the sample to cool on ice between sonication pulses for 30 seconds For example sonication can be carried out with a microtip attached to Branson 450 sonifier using the 25 power output setting 110 Bi County Blvd Ste 122 Farmingdale NY 11735 Page 5 Tel 1 877 374 4368 m Fax 1 718 484 3956 m E mail info epigentek com m Web www epigentek com Printed 2013 12 13 Epigentek Group Inc All rights reserved Products are for research use only g Centrifuge at 12 000 rom at 4 C for 10 min h Transfer supernatant to a new vial i Add Chromatin Buffer at a 1 1 ratio e g add 50 ul of Chromatin Buffer to 50 ul of re suspended chromatin Now the chromatin solution can be used immediately or stored at 80 C after aliquoting until further use Avoid repeated freeze thaw cycles TROUBLESHOOTING Problem Possible Cause Suggestion Low chromatin yield Insufficient sample size To obtain the best results the sample size per ChIP reaction should be between 100 200 mg of tissue Insufficient chromatin a Check that all of the reagents have been extraction added in the correct volumes and in the correct order based on the sample amount b check sample lysis under microscope after addition of lysis buffer and c check if the plant tissue type is compatible with this extraction procedure Use of expired lysis or Check the expiration date of the kit wh
7. m infiltration for an additional 5 minutes Remove the formaldehyde and rinse the tissue 2 times with 20 ml of deionized water After the rinses remove as much water as possible at this stage the cross linked tissue can be either frozen in liquid nitrogen and stored at 80 C or used directly for chromatin extraction 3 Tissue Lysis and Chromatin Extraction a Grind the tissue in liquid nitrogen to a fine powder Pour the powder into a 50 ml conical tube and add 4 ml of cold Working Lysis Buffer 1X per 200 mg of tissue Vortex and place on ice Filter the solution through 2 layers of Miracloth into a 50 ml conical tube and centrifuge the filtered solution at 4000 rom 1900X G for 20 minutes Remove supernatant and re suspend the pellet in 0 3 ml of Working Extraction Buffer A per 200 mg of tissues Transfer the resuspended pellet to 1 5 ml vial and centrifuge at 12 000 rom for 10 minutes at 4 C to pellet nuclei white pellet should be seen at this stage Remove supernatant and re suspend the pellet in 100 ul of Working Extraction Buffer B per 200 mg of tissues Add 200 ul of Working Extraction Buffer B per 200 mg of tissue into a new 1 5 ml microcentrifuge tube Layer the re suspended pellet from Step 3d on top of this 200 ul cushion and centrifuge at 14 000 rpm for 45 min at 4 C Remove supernatant and re suspend chromatin pellet in 50 ul of Working Extraction Buffer C per 200 mg of tissue Note Optional Sonicate 2 cyc
8. ng step Vacuum dessicator for optional cross linking step 0 OF O 0 OQ Nylon mesh for optional cross linking step GENERAL PRODUCT INFORMATION Quality Control Each lot of the ChromaFlash Plant Chromatin Extraction Kit is tested against predetermined specifications to ensure consistent product quality Epigentek guarantees the performance of all products in the manner described in our product instructions Product Warranty If this product does not meet your expectations simply contact our technical support unit or your regional distributor We also encourage you to contact us if you have any suggestions about product performance or new applications and techniques Safety Suitable lab coat disposable gloves and proper eye protection are required when working with this product Product Updates Epigentek reserves the right to change or modify any product to enhance its performance and design The information in this User Guide is subject to change at any time without notice Thus only use the User Guide that was supplied with the kit when using that kit Usage Limitation The ChromaFlash Plant Chromatin Extraction Kit is for research use only and is not intended for diagnostic or therapeutic application A BRIEF OVERVIEW Chromatin immunoprecipitation ChIP offers an advantageous tool for studying protein DNA interaction With ChIP the experimenter can determine if a specific protein binds to specific sequences of a gene
9. ty Blvd Ste 122 Farmingdale NY 11735 Page 1 Tel 1 877 374 4368 m Fax 1 718 484 3956 m E mail info epigentek com Web www epigentek com Printed 2013 12 13 Epigentek Group Inc All rights reserved Products are for research use only KIT CONTENTS P 2022 050 o Receipt aeaa o OO Spin the solution down to the bottom prior to use SHIPPING amp STORAGE The kit is shipped in two parts the first part at ambient room temperature and the second part on frozen ice packs at 4 C Upon receipt 1 Store Protease Inhibitor Cocktails at 4 C 2 Store remaining components at room temperature All components of the kit are stable for 6 months from the date of shipment when stored properly MATERIALS REQUIRED BUT NOT SUPPLIED Sonicator Vortex mixer Centrifuge including desktop centrifuge up to 14 000 rpm Pipettes and pipette tips 1 5 ml microcentrifuge tubes 15 ml conical tube 50 ml conical tubes Cells or tissues Cell culture medium B mercaptoethanol BME 1X PBS Oo 0 O OF 0 0 0 O0 O0 OO O OQ Distilled water 110 Bi County Blvd Ste 122 Farmingdale NY 11735 Page 2 Tel 1 877 374 4368 m Fax 1 718 484 3956 m E mail info epigentek com m Web www epigentek com Printed 2013 12 13 Epigentek Group Inc All rights reserved Products are for research use only Miracloth or similar filtration material 37 formaldehyde for optional cross linking step 2 M glycine solution for optional cross linki
Download Pdf Manuals
Related Search
Related Contents
ライカ DM750 取扱説明書 - Leica Microsystems Avaya 1416 and 1408 Digital Telephones Release 4 Service Pack 2 User's Manual Tripp Lite External Battery Frame for Extended Runtime for select SmartOnline 20kVA & 30kVA 3-Phase UPS Systems Nokia 6110 Navigator Black Owner's manual · Anleitung Handleiding · Mode d - NT Copyright © All rights reserved.
Failed to retrieve file