Home
TTDM-128 Commissioning Record
Contents
1. Commissioning Record TraceTek Leak Detection System tyca How Control TTDM 128 Alarm amp Locating Module Tyce Thermal Centros Company Owning or Authorized TraceTek Operating Facility service company Building unit Address Site Address Contact person Telephone email 4 General settings After silencing alarm press menu and select View edit settings Language selected Affix front panel label in chosen language Change time date to local time Set units 2 TTDM Installation Inspection on Visual Inspection 5 Self Tests with UI Software Seating of circuit boards Contact person Telephone email 1 System Configuration Single channel stand alone system Single channel with remote repeater Single TTDM with TTSIM network Multiple TTDM network system Other zones UI Test Audio Tests 8 o 3 Memory Tests Display Test 5 3 Wiring check all that are applicable lee Keypad
2. modules Ground earth Alert response personnel before testing relays or other Power supply wiring interfaces if connected Sensing cable naay asl ia Zener barrier 4 20 mA Test if installed and connected Failt rela Host port comm Loop back test requires aay transmit receive jumper Service rela 4 20 mA 6 Leak and Port Settings Host port RS 232 RS 485 Leak Default Other RS 485 SIM network port Re alarm interval Never TT NRM Quantity Auto Reset Off On External TTSIM Quantity Alarm re flash Off On Alarm Reset Single All 3 TTDM Initial Power up Test Host port Close enclosure and supply power to the unit Baud 9600 ae 485 Access 1 l Mode switch RS 232 RS 485 Finds all connected SIM TTSIM and TT NRM TTDM haciar Slave Tra K Commissioning Record TraceTek Leak Detection System TTDM 128 Alarm amp Locating Module Complete a copy of this page for each SIM or TTSIM installed in the system 7 Application 10 Relay configuration Beneath raised floor Sumps Complete this section for TTSIM 1A or TTSIM 2 modules Double contained piping Trench or when TT NRMs are installed Double contained tanks Overhead piping TT NRM Regions and Relays Buried pipeline AST Other Trace Tek Sensors connected Type Approx length TT1000 water sensing TT3000 conductive liquids TT5000 fuel sensing TT5001 solvent sensing Other Othe
3. on and Maintenance Training This documentation was provided and reviewed with the end user Project specific documents General installation instructions General instructions for commercial buildings General instructions for environmental applications Sensor installation instructions TT1000 modular sensing cables TT3000 and TT5000 series modular sensing cables TT3000 and TT5000 series bulk sensing cables TTDM 128 Documentation TTDM 128 Installation Instructions TTDM 128 User Manual Signatures Test performed by Name Signature Date Client acceptance Name Signature Date Copies to 1 Client 2 TraceTek service representative 3 Tyco Thermal Controls 300 Constitution Dr R51 1A Menlo Park CA 94025 1164 USA www tycothermal com
4. r Visual Inspection Q S o 6 a 2 2 2 Wiring check all that are applicable Ground earth SIM relay Power supply wiring Alarm mode Leak Leak Break Sensing cable Alarm state On Off Zener barrier Alarm reset Auto Manual Safe Internal SIM External TTSIM Quantity 11 Sensor Mapping RS 485 connection Record TTDM 128 Leak location reading for simulated leaks created at key points on the system 9 Sensor and System Settings At the TTDM select this channel then press the down EOcaHon ea ocaon arrow and record S o Tt SIM Address gy Ft ID A a DA Status ee op E L Test length ft m z E E A Sense Current uA Sn Ft m Service alert gt uA ee m Sense Resistance KQ Ft m Leak alarm lt KQ RG Resistance L 12 Acceptance Test YB Resistance When sensor is subjected to a simulated leak SI Version System detects and locates simulated leak SI Comm Acceptance test was performed in presence of owner s representative Yes No Tra K SIM Channel Commissioning Record TraceTek Leak Detection System TTDM 128 SIM amp TTSIM Module 13 Operati
Download Pdf Manuals
Related Search
Related Contents
サンリオ(8136) - シェアードリサーチ Regolamento 208/2015 RVFSR in lingua italiana 77月 - 津久見市 LOEWE ART 40 40" Full HD 3D compatibility Smart TV Wi-Fi White Modo de empleo IMPRESSA XJ9 Professional Soluções de problemas MZ6AK et MZ6AK_CVS Manuel de l`utilisateur Copyright © All rights reserved.
Failed to retrieve file