Home

User manual Standalone Proximity Reader CFX-SR

image

Contents

1. Reliable Durable Affordable roshox SR 2400 Quick reference Programming Guide Function description Choose from the relevant function below and input ssssss Enter the programmingmode then you cando the programming 888888 is the default factory master code Note that to undertake thefollowing programming the masteruser must enter into the programming mode Change the master code O New code Repeat New code Code must be 6 8digit numbers 1 Read Card ademi a Read Card Can add cardcontinuously 2 Read Cara Can delete cardcontinuously Delete card user To Unlockthe door To Unlock the door Read user card Attachment Advanced Application 1 SR 2400 operating as a Controller In this mode the SR 2400 supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the CFX SR 2400 Either an ID card reader 125 KHZ or an IC card reader 13 56MHZ can be connected to the CrosFox Cards are required to be added at the external reader except where an externalEM reader is used in this case cards can be added at either reader or controller See figure 1 SR 2400 controller wiegand reader DC12V 3A o a Red Black Blue Purple Orange Figure 1 2 SR 2400 operating isa Wiegand Output Reader In this mode the SR 2400 supports a Wiegand 26 bit Output so the Wiegand data lines can be connect
2. Lroshoy Reliable Durable Affordable CFX SR 2400 Waterproof Standalone Proximity Reader User manual 1 Packing List Standalone Proximity Reader SR 2400 Ser that allthe above contents arecorrect If any aremissing please notify thesupplier of the 2 Description The SR 2400 is fully waterproof standalone Proximity access Reader which uses advanced microprocessor equipped with large capacity Flash memory supports up to 10 000 cards It is so easy to add or delete card users by using the master card besides with Infrared remote control programmerthe user can set the features by themselves including Alarm Self protection interlock and Anti submarine back Function In additional with infrared remotecontrol interlock and Anti submarine back Function In additional with infrared remote The SR 2400 not only has the features of low power consumption automatic selection of lock anti vandal alarm and exit button ut also has the protective functionsagainst input over voltage and outputs short circuit These features make the SR 2400 reliablend easy in operation It is an ideal choice for door access 3 Features e Can be used as salve reader e 2 pcsW can be interconnected interlocked e Can be used as controller by connecting slave reader e Anti submarine back Function e Alarm signal output Door open detection e Full of 10 000 users recognizing speed lt 15ms e Standalone Card Reader e User capacity 1
3. an optional magnetic contact or built in magnetic contact ofthe lock ifthe door is forced open orif the dooris opened after 120 seconds ofthe electro mechanical lock not closed properly the inside buzzer and alarm outputwill both operate Todisable door open detection Factory default 6 o Toenable door open detection 6 1 Security Mode Setting Reader Lockout amp Alarm Output options If there are 10 invalid cards within 1 0 minutes the Reader will lockout for 10 minutes orthe alarm will operate for 10 minutes depending on the option selected below Normal status Nolockout or alarm 7 0 Factory default setting Reader Lockout Alarm Output Door Interlock Door interlock disabled 8 lo Door interlock enabled a 1 Alarm output time To setthe alarm output ime 0 3 minutes Factory default is1 minute 9 0 3 k To removethe alarm Toremove the doorforced open warning Read valid cardor Master Code Toremove the dooropen too long Close the door orfRead valid card warning or Master Code To Unlockthe door To Unlock the door Note that Manager Card can tbe used to unlockthe door 6
4. lo New Password RepeatNew Password Tochange the mastercode The master codemust be 6 8 digit number Read Card Card can beadded continuously without exiting programming mode Input Card number 8 digit The card numberis the last8 digits ofthe number printing onthe card 2 Read Cara lor 2 Card number 83i F o deleteALL users Note This option will delete all users but 0000 Manager Cards Be carefulwith use 10 2 Door setting Toadd a carduser Method 1 Toadd a carduser Method 2 Todelete a carduser Lock Power Setting Fail secure Unlocked when power on This is the factorydefault 3 seconds 0 99 is to setthe door relay time0 99 seconds 5 Lo 99 Fail safe unlocked whenpower is off 0 99 is to setthe door relay time0 99 seconds Anti submarine Settings Anti submarine Disabled 3 0 Factory default Anti submarine Master Mode BE Antisubmarine Auxiliary Mode 3 2 Note the detailed wiring diagramand illustration please referto the Advanced application Door open detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with
5. 0 000 e Card interface 125KHZ EM Card e Remote control for programming e With Manager cards for fast add and delete users e Wiegand 26 input output 4 Specifications Lock output load User capacity 10 000 Dimensions 103 x 48 x23mm Temperature Sleeping Current Humidity Card type 125KHZ EM card 5 Installation e Drill holes on the wall or prepare the cassette e Wire through the hole and blanket the unused cable in case of short circuit e Fix the back cover firmly on the cassette or the wall e Attach the reader to the back cover Shielded cables eee gt 6 Wiring Description Green DO O Wiegand output inputsignal wire DO White Pe Rea av 09 12Vde PositveRegulated Power input ove ws GARNER SHEN part of Exitbutton and door contact o Purple 1 f Connecttomenegatvepole ofthe Lock Connection Diagram SR 2400 Green White Grey Yellow Brown Red Green White Grey Yellow a door detecting switch door detecting s Do not poweron until allwiring has beencompleted ee Common Power Supply DC12V 3A 9 DC12V 3A PUSH NC COM NO yoo ayes j1e4 Special Power Supply OOO OO yoojaunses jie4 7 Interface Circuits Lock Interface Principle Alarm Interface Principle By programme setting I O 12V when alarm the I O outputs high level switch between low level and high level 4 low level 5 high level Figure
6. 1 NOTE The above diagrams show the output interface circuits Unlike most lock and alarm outputs which use a relay that can be shocked or magnetized the SR 2400 uses MOS outputs for both the Lock Output on the left and the Alarm Output on theright 8 To Reset to Factory Default and Manager Card setting Power off use the supplied Contact Pin to short out the 2P socket on the mainboard then power on if successful the beeper will beep twice the LED shines in orange remove the Short Pin then read any two EM cards after that the LED turns in red means reset to factory default setting successfully of the two EM cards read the first one is Manageradd card the second one is Manager delete card Remarks Reset to factory default setting the users information enrolled is still retained When reset to Factory default setting the two Manager cards must be re enrolled 9 Sound and Light indication Sleeping mode Redshinessow Operation success SCC Operation taea O Threesrortring 10 SR 2400 Detailed Programming Guide 10 1 User settings There are 2 waysto add and delete users add card Cards can be addedcontinuously Cards canbe deleted continuously B By Remote control Manager Password 888888 is the default factory master code ToAdd user by ManagerCard To Delete User by Manager Card ToEnter the programming mode Remarks All thesteps below mustbe done afterentering into programming mode
7. ed to any controller which supports a Wiegand 26 bit input Seefigure 2 Yellow Brown Red Black Blue D Purple 2 Orange Controller with wiegand 26 input figure 2 3 Two CFX SR 2400 units interconnected for a single door In this mode two SR 2400 units are us fora single door one for entry and the other for exit Either device acts as the controller and reader at the same time Users can be enrolled in either of the devices In this mode the user capacity for one door can be up to 20000 The setting ofthe two SR 2400 units must be the same including the same including the master code See figure 3 4 Two CFX SR 2400 units interconnected amp interlocked for 2 doors two doors In this mode two SR 2400 units are used for two door swhich are then interconnected and interlocked In this mode the doors canbe interlocked so that when door 1 is open door 2 cannot be opened and vice versaThe interlocked function is mainly prisons and other places where a higher levelof securityis required See figure 4 outdoor Green Green i White White Grey Grey Yellow Yellow door detecting switch Red Black Blue Blue Purple Purple Orange SR 2400 controller 1 SR 2400 controller 2 figure 3 SR 2400 controller 2 SR 2400 controller 1 DC12V 3A figure 4 5 Anti submarine functionfor single door 3 1 The connection diagramis as figure 1 Install one Wiegand reader ora SR 2400 without user information as read
8. er outside the door connecting to one SR 24000 Controller inside the door which acts as the Anti submarine Master unit of the two devices they build up an anti submarine system for single door The operation and function is as below 5 1 Set the needed function and enroll the User Cards on the inside SR 2400 Anti submarine Master unit 5 2 With the valid user card the user can only enter the door from the outside reader and exit fromthe inside SR 2400 Controller Onthe other hand without entering record from the reader the user can texit fromthecontroller inside also the user can tenter in twice without the first exit record and vice versa Anti submarine function for 2 doors The connection diagramis as Figure 4 Door 1 with one SR 2400 and Door 2 with one SR 2400 set one SR 2400 on Door 1 as the Anti submarine Auxiliary 3 2 unit and set the other SR 2400 on Door 2 as the Anti submarine Master unit 3 1 They build up a anti submarine system which is normally used for parking lot etc The operation andfunction is as below 6 1 Set the needed function and enrollthe User Cards from SR 2400 Anti submarine Master unit on Door 2 6 2 With the validuser card the user can onlyenter in from Door 1 andexit from Door 2 On the other hand without entering record from the Auxiliary unit the user can t exit from the Master unitor Auxiliary unit also the usercan t enter in twicewithout the first exit record and vice versa

Download Pdf Manuals

image

Related Search

Related Contents

VM 480 - Domyos    Samsung 170T Benutzerhandbuch  

Copyright © All rights reserved.
Failed to retrieve file