Home
LWS Electrical Information
Contents
1. Rese HX VWG2008V2 XXV E Understanding batteries and suggested menu settings The HX VWG2008 hybrid charge controller is preconfigured with default settings in the user programmable locations Default 12 volt battery Default 24 volt battery Charge off 14 32 volts 28 64 volts User off 10 98 volts 21 97 volts User on 12 44 volts 24 88 volts Brake current 40 amp 20 amp Brake time 50 seconds 50 seconds The information below is provided as a guide only The users should do their own research Wet Cell flooded Gel Cell and Absorbed Glass Mat AGM are various versions of lead acid batteries Lead acid batteries should never be run flat The maximum recommended discharge is 75 of the total This means that the battery should have a minimum of 25 of charge remaining when it is put on charge The chart below indicates the amount of charge a battery has at the voltages shown Charge State 12 volt battery 24 volt battery 100 fully charged 12 65 volts 25 30 volts 75 12 45 volts 24 90 volts 50 12 24 volts 24 48 volts 25 12 06 volts 24 12 volts Discharged 11 9 volts 23 8 volts If you wish to get the maximum life from a battery it is best to ensure it is not discharged more than 75 at any time In fact slightly less is ideal Therefore for maximum battery life set User off to 12 46V 24 92V and User on to 12 65V 25 30V If you use very little load and the t
2. result in the destruction of both the hybrid charge controller and the wind turbine and possible serious injury or death Refer to connection diagram on next page Do not erect or connect the turbine to the charge controller in windy conditions Always have the 3 wires from the turbine shorted together if not connected to the hybrid charge controller Ensure correct polarity is observed at all times i e Positive to positive and negative to negative for ALL connections Failure to comply to this will void warranty Steps 1 Always connect the battery to the charge controller first as shown in the diagram on the next page 2 Ensure brake switch is on Do not proceed to the next step in windy conditions 3 Remove one wire from the turbine leaving the other two shorted together and connect it to the hybrid charge controller as shown below 4 Remove the second wire and connect it to the hybrid charge controller Note that at this point there is no load on the turbine until the second wire is connected to the hybrid charge controller so do this step as quickly as possible and NEVER do this in windy conditions 5 Connect the third turbine wire The turbine is now protected 6 Connect solar if have it as shown below 7 Release brake switch and confirm turbine spins 8 Do not connect the load at this time until you have programmed the hybrid charge controller to values to suit the load Connection diagram WINDGE
3. HX VWG2008 Wind amp Solar Hybrid Charge Controller User Manual Please read this manual very carefully Failure to do so may result in serious injury and permanent damage to the hybrid charge controller and attached wind turbine While every attempt has been made to ensure the information contained in this guide is accurate we advise that we will not be liable for any omissions or inaccuracies Contents A I o m Safety Features Connection Menu system Understanding batteries and suggested menu settings Troubleshooting Specifications A Safety This manual must be fully read and understood before installation If you feel you do not have the necessary ability to connect this device contact your distributor Failure to connect the hybrid charge controller as indicated in Part C of this manual could result in the destruction of both the hybrid charge controller and the wind turbine Wind turbines must be connected to a load at all times The hybrid charge controller is designed to fully protect the attached turbine Other important matters Do not allow the unit to be exposed to moisture rain or other liquids Protect the unit from direct sun and excess heat Ensure the unit is protected from unauthorised access including children Ensure all components are rated at the same voltage i e If you have a turbine rated at 12 volts the solar panel and battery should also be rated at 12 volts The same applie
4. NERATOR BATTERY 8GA cable size is recommended for short cable runs lt 15 metres and heavier cable for longer runs to reduce cable losses D Menu system EXWVWE2008V20NWIAIB LCD display MEN press button n Menu display tl q User onxx xxV Useroff XXXV es HX VWG2008V2 NLH B gt U xx xxV xx xxA gt Charge off xx xx V l Brake time xxx SEC _ salen 1 gt Press MENU ti Brake on xx A Charge XXX KWH tl Press BE i User xx x A Power XXX W il User XXX Ah n Boot screen XVWE2008VAININB 12V battery mode XWVWE2008V2INFIB 24V battery mode n Examine battery voltage and charge current U Battery voltage unit V charge current unit A n Setup battery charge off voltage Charge off xx xx V EE Charge off xx xx V n Examine charge cumulative AH eiaa Charge charging AH Unit AH n Examine wind generator and PV total power generated Charge power generated Unit KWH n Examine wind generator and PV instantaneous power Power Instantaneous power Unit Watts n Examine discharge total AH USA User discharge AH Unit AH n Setup load power off voltage User off xx xx V Bt User off xx xx V n Setup load boot strap voltage User on xx xx V MH User on xx xx V n Examine discharge current n Setup brake current BrakeonXXA ME Brake on XXA n Setup brake time Brake time xxx SEC MH Brake time xxx SEC n Load over current protection Load overCurrent
5. s for 24 volt systems Ensure the total wattage of the unit is not exceeded ie for the HX VWG2008 the TOTAL input is 600 watts with the ideal mix being 500 watt turbine and 100 watt solar Ensure all connections are firmly tightened Select suitably wire sizes for the currents being generated B Features The HX VWG2008 hybrid charge controller is a smart controller The integrated micro computer monitors all the necessary inputs and outputs to ensure precise control Key features LCD display with input keys to allow user to alter values The unit will store information such as o Total amps generated o Total Kw hours generated o Amps used by load o And many more Connection of both solar and wind Auto sensing of voltage of batteries connected Ensures the battery is maintained in best possible condition by preventing overcharging and over discharging Automatic braking of the turbine when battery fully charged and or no load connected Automatic braking of the turbine when charge current is too high i e in very high winds Manual brake switch A Load output where external devices can be switched on and off at user determined voltages The load output is also current limited to protect the connected device Brake time is programmable Reverse polarity protection for both battery and solar panel Protection from lightening strike C Connection IMPORTANT Failure to connect the hybrid charge controller as indicated could
6. urbine is constantly braking due to a fully charged battery condition reducing the Charge off voltage to 13 5V 27V will also prevent constant overcharge conditions F Troubleshooting Condition Cause Fix No display Battery discharged not connected or faulty Recharge battery check connections or replace battery LCD Display Overload The load is drawing excess current Correct overload condition short circuit and press Reset Turbine not spinning Brake switch is on Turn off brake switch Battery not charging Battery too old Replace battery G Specifications Main parameters MODEL Rated Power Applicable batteries Wind turbine automatically braking voltage Battery full charge cut Battery low voltage disconnect load Load on voltage Charge current max Load current max Recovery time after the automatic braking No load loss Dimensions Weight Working environment VWG2008 600W Best ration wind turbine500W PV cells100W 12 24V 100 300Ah automatic distinguish voltage 17 5V 32 5V DC voltage after rectification 14 4V 28 8V default adjustable 10 5V 21 8V default adjustable 12 6V 25 2V default adjustable 40A 20A 35 61A 17 80A 1min default adjustable lt 40mA 228 133x75mm 1 2kg Environment temperature 10 C 50 C Relative humidity 0 90
Download Pdf Manuals
Related Search
Related Contents
MANUAL DEL OPERADOR Vannes papillon VAMEIN oreilles Lisses(série 37-100 Mode d`emploi régulateur VIVOX ver307| 1 MODE D`EMPLOI Kurz Bedienungsanleitung Philips BDP3406M2 Operating Instructions Manual DOSSIER DE PRESSE - Fêtes de Bayonne AcuDis115 User Manual - Acura Embedded Systems Faze Stream 700 User Manual 3412E and C30 Marine Engines-Maintenance - Safety Copyright © All rights reserved.
Failed to retrieve file