1. 4 Click OK Making Adjustments on Analog Input Devices To make adjustments on Analog Input devices 1 On the Input Device summary click the Item to adjust 2 On the Action menu click Sensor Settings The Input Device Operation dialog box appears 3 Make the necessary adjustments 4 Click OK Note When adjusting the Day Night Adjustment first define the Day Night Adjustment feature on the IFC 1010 2020 8 6 Operator Workstation User s Manual Performing a Communication Command To perform a Communication command 1 Select the desired objects to command 2 On the Action menu click Communication The Communication dialog box appears Figure 8 2 COMMUNICATION Binary Output Communication pooscssoasoscocoscescesososeososcsososcocoscossocsccessecosossococcossosescesee Cancel if C Disable Communications C Unlock Reporting Lock Reporting C Unlock Triggers Lock Triggers Figure 8 2 Communication Command Dialog Box 3 Click the desired command option button 4 Click OK
2. Manual 8 3 Though the Operation command options differ depending on the type of object the process of commanding is the same for all objects with the exception of Fire Object Analog Input devices Performing a Fire Object Analog Input Device Command By using the Operation option in the Action menu while an Input summary is displayed operators can adjust some of the operations for Analog Input devices detectors The adjustments include e adjust Default Sensitivity e enable or disable the Verify attribute e enable or disable Day Night Adjustment Default Sensitivity The Default Sensitivity can be set to three different levels High Medium and Low It tells the Analog Input device detector when to consider input valid for triggering alarms A setting of High makes the detector very sensitive to even small amounts of smoke Low sensitivity means more smoke would have to be detected to trigger an alarm Operators can tell what the device is set to by looking in the Default Sensitivity field in the Input Device summary Verify Verify has two settings Enable and Disable If Verify is set to Enable it allows an Analog Input device detector to count the number of times its threshold is momentarily exceeded Enabling this setting can help prevent unnecessary alarms If this setting is disabled the Verify Count field in the Input Device summary will be blank Day Night Adjustment Day Night Adjustment has two settings Enable a
3. Operator Workstation User s Manual 8 1 Chapter 8 Commanding Objects Introduction This section tells you how to command objects This chapter explains how to e perform an Operation command e make adjustments on Analog Input devices e perform a Communication command November 1 2001 Johnson Controls Inc www johnsoncontrols com Code No LIT 120172 8 2 Operator Workstation User s Manual Key Concepts Commands Commands tell an object to perform or to stop performing certain functions There are two kinds of commands Operation commands and Communication commands Operation commands direct the actual functioning of the object Operation Commands Operation commands are used to e turn objects On or Off e put objects in override e adjust analog output setpoints e setan object s High and Low Warning Limits e adjust Fire Object Analog Input devices The type of object you are commanding determines the available Operation commands The following Operation commands are available e Adjust e Auto e State 0 or Off Stop e State 1 or On Start e Release All e Override Note In the Command dialog boxes State 0 and State 1 are replaced by the display units specified for the selected object for example Off On Stop Start If commanding an Analog Input object the following Operation commands are available e Auto e Override e Alarm Limits e Warning Limits Operator Workstation User s
4. nd Disable If Day Night Adjustment is set to Enable the sensitivity level can automatically change according to the time of day This prevents unnecessary alarms Day Night Adjustment must be fully set up at the IFC 1010 2020 before this feature operates properly 8 4 Operator Workstation User s Manual Communication Commands Communication commands determine how the object interacts with other parts of the system For example use the Lock Triggers Communication command to prevent an object from triggering a GPL process Use the Unlock Reporting command to allow reports regarding an object to be sent to report destinations Communication commands are the same for all objects except that Unlock and Lock Reports commands are not available for DCM XM LCD DCDR N2Open and DSC hardware objects The following communication commands are available e Enable Communications e Disable Communications e Unlock Reports e Lock Reports e Unlock Triggers e Lock Triggers Operator Workstation User s Manual 8 5 Detailed Procedures Performing an Operation Command To perform an Operation command 1 Select the desired objects to command 2 On the Action menu click Selection Operation The Operation dialog box appears Figure 8 1 OPERATION Binary Output r Operation Auto C Release All Cancel C OFF C Override Figure 8 1 Operation Command Dialog Box for BO Object 3 Click the desired command

Download Pdf Manuals

image

Related Search

Related Contents

BERNINA 780  DF-RS12 取扱説明書      ADVERTENCIA  RM-P1000 (B)  Star Micronics TSP800 TSP847  Exmark MHP3614KA User's Manual  

Copyright © All rights reserved.
Failed to retrieve file