Home

Personal Scale VRB-250 and 300

image

Contents

1. VETEK USER MANUAL VETEK N Ld als Personal Scale VRB 250 and 300 USER MANUAL C Map A Read this manual carefully before using the instrument INDEX 2 EEA ates cece essence cones ennnen 1 kkt Aor EANA nAEA tac orcaensceencaceuciasesceten AEEAEAILEAEAI LEESE EEEE I IEEE EIEEEI EEEE rran PAGE 2 3 T a A EEEE ANE EAEN PAGE 3 4 TECHNICAL SPECIFICATION ccccssccsscesssscsscsessesecsvssesecsesevsecsvsetsecsnsesseseesensesevsevssensecsesensecsnsevsnsessisensessuvensevsissesecstenseeeeee PAGE 3 5 PSV SOs T E E EE EEE E EE E O eee PAGE 4 6 INSTALLATION A PAGE 5 7 INSTRUCTION FOR USE cccscsscssessesesesecsesevsecsessesecsvsecseceesecsussnsecsusesessessnsesssensevensessetssevsessnsevssetsesssensetsssnsevssensessetesn PAGE 5 8 ENAA UNTON SA PAGE 8 9 SINCE E PAGE 9 10 ERROR Ae scarce emcee Ses corte eae gva sedans ue LAANA I LEAEEIEEEAEAIEAEAIEEEEEI EEE IIE EAE AEEEEEA IEEE IIIENA EEEE EIEEEI EEEE EEEE an PAGE 10 11 MAINTENANCE AND ASSISTANCE cccccccscsccsecsessessesesecsecsesecsecsesevssseesevsecensessusensevsseesessesessessnsessssisevssentetsesnsevsetersevseeeeen PAGE 10 12 CONFORMITY ccscsccscesessescsesscssesesecssesessvsevesecsesssecsusessecssessessusensecsusensevssensessisessivensevsisensetsetensensesenseusevensessesensetesensees PAGE 10 13 IDENTIFICAMON LABELS sissipisearninaiienonenitai tiirus napananatili atadai iaaeaie Taaa radaas abs raient ana iarainn le inas PAGE 11 14 SCRAPPING AND WAS
2. VETEK USER MANUAL recommended to press HOLD BMI key after the person moves on the tread platform 7 5 BMI function In normal mode long press HOLD BMI key 3sec to enter into BMI mode The second display will show last height and the extreme left digit will blink Use TARE to decrease value and press HOLD to change to next digit Press ON ZERO OFF key to confirm height value When the display shows Hold please stand on the scale platform Proceed to weigh as normal The instrument will show the weight height and BMI value To release the locked weight on display simply press the HOLD BMI key again and the display will return to normal mode automatically 7 6 Tare function Tare allows the user to zero the instrument to cancel the weight of a container clothes from the reading of the instrument thus giving the true weight of the product person being tested CON LAOG H Turn on the scale using key 40 When 00 l displays on the screen and scale beeps twice Place the object clothes need to be tare on the tread platform Tana Press after the weight stabilizes and stable sign appears on the display lt O00 Display will return to E Place the item baby need to be weighed without removing the tare object The weighing result is the Net weight of the item baby TARA To delete the saved tare value remove the tare object from the tray and press A key
3. button to power on the printer Box 79 Industr at Al Oe aoe aah Wwww vetek com info vetek com ON 76040 V dd 2 A 15 5 i Oj VETEK USER MANUAL The PRINTER XL printer can be connected via the RS232 port and cable with the RA200 XL Press the PRINT key Print double language CHANGING THE PAPER ROLL The paper print roll on a PRINTER XL printer is changed as follows 1 Open the upper cover and position the paper roll so that it 2 Feed the end of the paper roll through the printer cover and feeds in the right direction close the cover The printer is ready to print a Ae Paper roll LOL gt Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 16 VETEK USER MANUAL 17 2 PRINTER SPECIFICATION Resolution dots mm Max paper thickness um Paper 9 7 5 0 5 mm W x y30mm max Operating temperature 9C Operating humidity 20 to 85 no condensation Conform to RS232 Voltage range adaptor only 12V 2A SHOCK HAZARD WARNING The printer and power supply should never be operated in a location where either one can get wet Personal injury could result MEDIA WARNING Always use high quality approved paper print roll The approved product can be ordered from your dealer RELOADING HINT If printer runs out of paper roll while printing switch the power off and reload paper roll Power on an
4. press the keys with sharp or pointed objects e Do not try to open the instrument e Do not remove seals from the instrument e Do not short circuit the battery terminals e Use only the power supply provided by Wunder Before using it make sure that the local mains voltage is compatible with the voltage of the adapter shown on the identification plate e Regularly check the integrity of the instrument s power cord and make sure it does not come in contact with hot appliances e Make sure that the power cord does not create obstruction hazards e Unplug the instrument before cleaning it e Do not place the instrument in water or other liquids e Perform maintenance and subsequent metric verifications regularly 4 THECHNICAL SPECIFICATION RB L Model RB Basic RB Medium RB with cable Capacity 200kg 300 kg 200kg Division 50 100g 100 g 50 100g MDD OIML Class Ill Unit weight kg Display LCD 1 con 5 digits attivi Function Key ON ZERO OFF HOLD BMI TARA PRINT Power Rechargeable Batteries Pack Adapter 12 V 2A Operation temperature da 5 C a 35 C 5 INDICATOR Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL a i C ee __ 1 Weighing capacity and division 5 2 Key function f 3 Main LCD Weight 4 Second LCD automatically ca
5. CEE CE 0470 14 SCRAPPING AND WASTE DISPOSAL If set aside for a long period protect those parts which could be damaged due to dust build up Scrapping When you decide to no longer use this item we recommend making it unusable We also recommend making those parts which could be sources of danger harmless Waste disposal X EU 2002 96 EC This product complies with the EU Directive 2002 96 EC The symbol of the crossed out waste bin on the appliance indicates that the product needing to be treated separately from household waste at the end of its useful life must be completed in a separate collection facility for electric and electronic appliances or returned to the dealer upon purchase of a new equivalent appliance The user is responsible for bringing the appliance to an appropriate collection structure at the end of its life Appropriate separate collection and sending the appliance for recycling treatment and environmentally compatible waste disposal contributes to avoid possible negative effects on the environment and health and favours the recycling of the materials the product is made of For more detailed information regarding available collection systems contact your local waste disposal service or the shop where the product was purchased As consumers you are obliged by law to return used or dead batteries You may deposit old batteries at public collection spots in your town or else with any battery dealer who has placed specific collector
6. TE DISPOSAL ccscscesesseseesessesecsesecsecseserseceesessecssesseussecsusesessisensevsnsensesensensevsnsessneensensevensesseseeseen PAGE 11 16 MRI scence alan cesses EAA E ET AEA A E PAGE 12 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL ccccscscessesessesesseseesesersecsessesecsesevteeetsensevetsevsneeeseen PAGE 13 17 THERMAL PRINTER OPTIONAL c cccccscscesesscsecseseesecsesseseesssessesesecsessuseesevsrsessusensecsisentetsivensessisensessatessessutersessevessetensensess PAGE 15 By choosing the WUNDER mod RB or RB L or RB cable professional electronic scale you have purchased a high precision instrument Since over 40 years WUNDER has placed its experience at the service of health This instrument is compliant with national standards in hospitals and clinics with medical class with measurement function and is calibrated in conformity with accuracy class III The instrument is characterised by the possibility of fixing the electronic terminal to the weighing platform by means of a column or else installing the terminal autonomously The instrument is equipped with a dual LCD electronic terminal with triple reading to simultaneously view Weight Height and BMI Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL 2 GENERAL RULES A Carefully read this manual before using the instrument as it supplies important i
7. again Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL 8 PRINTER FUNCTIONS Weight can be printed for records using RS232 interface cable After weighing simply press PRINT key to print out the results The format presented below is the standard format of results print out and cannot be changed More informations info wunder it or service wunder it WUNDER Date Month Year hour minute Set parameters of the scale interface on the connected device It is not possible to change the scale Peso Weight 30 00kg Altezza Height 100 0cm parameters Indice Massa Corporea 30 0 BMI Body Mass Index Baud rate 9600 bps Sottopeso Underweight lt 18 Normopeso Parity check None Sovrappeso Pre obesity 2529 9 Data length 8 bits Obesita calaae I Obesity class I 3 Obesit calaae II Stop bit 1 bit Obesity class II Obesita calaae III a diaa Handshake RTS CTS Data code ASCII Ps Serial RS232 PIN 3 B a B OO bo PIN 6 PN Connector RS232 Connecting with PC Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal New Connection Description Give new connection a name then click OK Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then clic
8. ch on the scale using 25 key The diagnostic scale self check is performed and the software version is displayed an y A iN The 0 00 kg weight displays on the screen now the scale is ready for weighing iO Note If display is not at 0 0kg while switching power on Kindly press 2257 key to zero the scale which can be used at any time to zero the scale YU fr amp 7 4 Hold function The scale is provided with the integrated hold function to determine the average weight It enables people to be weighed accurately although they are not still on the scale platform e Switch ON the scale using ON ZERO OFF key The diagnostic self check will be performed and after that 0 0 kg will display on the screen with stable and zero sign e Move the object person on the scale platform e Press the HOLD BMI key once The HOLD will display on the screen with blinking triangle and after few seconds the average of fluctuating weight will display on the screen and will lock on the display e Torelease the locked weight on display simply press the HOLD BMI key again and the display will return to normal mode automatically HOLD BMI key function can be activated before or after putting the weight on the tread platform But in case of weighing unstable person it is Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com
9. d print again Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 17 VETEK USER MANUAL 17 3 ERROR MESSAGES Problem Solution or Reason Status Indicator does not light when power Check the power connections from AC outlet to the printer power supply switch is turned to ON I position Status indicator illuminated green light but Check interface cable connections from the scale to printer the printer will not print Make sure the top cover is closed and locked Printer paper jammed Reset the paper roll Please refer to CHANGING THE PAPER ROLL Paper roll is out Reload a new source of paper roll so the printer can continue printing Please refer Status Indicator is flashing green to CHANGING THE PAPER ROLL Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 18
10. e sure not to subject the instrument to blows or excessive mechanical stress In case of repairs or assistance contact your dealer or an authorised service centre contacting service2 wunder it or sales wunder it 12 CONFORMITY WUNDER MODEL RB or RB L or RB CABLE ELECTRONIC SCALE SERIAL N We hereby certify that this instrument has been inspected and has successfully passed the functional test Itcomplies with the following standards and directives EN 45501 EN60601 1 2 EN60601 1 93 42 EEC Medical Devices Directive 13 IDENTIFICATION LABELS Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 10 VETEK USER MANUAL WUNDER SABI sri DK 0199 336 RB VANO BATTERIE M 1 3 0291 Per la sostituzione della batteria modello ricaricabile tipo RETC 7 2 V 2000 mAh sanger kg vedere il manuale di istruzioni RB WU 150 D Ta 300 kg To replace the battery Matr 0021 5 C 35 C rechargeable sealed type RETC 7 2 V 2000 mAh see the manual WUNDER Sa Bi S r L ce ol AN Temperatura di stoccaggio 0 60 C Model RB W150 _ 12V 2A Internally powered equipment with battery Eaceneeeeeseseeees or supplied by external model AD 8057 DK Storage Conditions Temperature 0 60 C Internamente alimentata con batteria odaAC DC alimentatore esterno modello AD 8057 DK RB RB L stoccaggio SER NR CONFORME ALLA DIRETTIVA 93 42
11. f its improper use e damage caused by an insufficient or inadequate electrical system or alterations resulting from environmental climatic or other types of conditions e damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel e Interventions at home for convenience controls or presumed defects e Routine maintenance and that which can be considered normal wear from use e consumables such as power supplies batteries keyboards plates wheels heads rolls load cells faulty due to blows or overloads Service can also be refused when the appliance has been changed or transformed in any way In case of interventions at one s home the customer must pay the fixed fee if however the appliance is repaired at an authorised Wunder Service Centre expenses and relative travel risk are borne by the user Wunder will not be held liable for damage of any nature caused directly or indirectly to persons animals or objects resulting from failure to comply with all the instructions indicated in this manual or anyway resulting from improper use The Court of Bergamo has jurisdiction in case of any dispute Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 12 VETEK USER MANUAL 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL A ATTENTION ONLY FOR COLUMN SCALE HEIGHT ROD KIT 1 Metal support for elescopic heigh
12. h the top row with the flashing digit Press PRINT key after successful change to move to next step EX To input Dec 25 2008 8 00am Enter year Using TARE keys to decrease the value press HOLD key to move to next digit Press PRINT key after successful entry to move to next stage Enter date Using TARE keys to decrease the value press HOLD key to move to next digit Press PRINT key after successful entry to move to next stage Enter time Using TARE keys to decrease the value press HOLD key to move to next digit Press PRINT key after successful setting 2008 A 225 gt ggg Display Format YYYYMM DD gt TTSS 7 2 Instruction for charging and connecting If L G prompt displays on the LCD please charge the scale with exclusive adaptor Locate adaptor plug on the rear side of indicator Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL The battery should be recharged at least every 3 months regardless if it is used or not After a long period in storage e g over 3 months the battery should run a full cycle charge discharge to allow it to restore to full capacity Ac Jack connector 1 Open the battery cover and take the battery out 2 Disconnect the rechargeable battery pack then replace it by a new one Put the battery back then arrange the connector in place well 7 3Weighing a Swit
13. k OK Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Hardware Then click OK to complete your setting Output Data When press the PRINT key to output data from scale to PC or an Optional Printer 9 SETTING SETUP tama Switch ON the scale and long press A key for 3 seconds first SETUP and then A OFF will display successively AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enables operator to select beep sound ON OFF TARA Press key 3 seconds HOLD key means enter gt SE UP _ ROFF 20S OS 2405 3005 pe i ARE key means select I5 TARE i HOLD HOLD bero h ODF m TARE End End Note To confirm the settings please press Ww when displays on the display 10 ERROR MESSAGE Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL Low Battery Please replace a new battery or plug D This warning shows that the voltage of the AC adaptor for operation L E battery is too low to use Overload Please reduce the loadi
14. lculates BMI 5 Power display 2 pa o O ww faa Bh Go Ca C amp D Key functions Key Description Key ON To reset the display OFF continuos press 3 seconds Zero the scale 2 of full capacity To hold weighing result on the display determine stable weighing value Function BMI Gt Tare un wanted weight Print uot data Function Display Symbols Net weight Stable symbol To indicate that the weight is stable Weight stable Hold function Weight 4 Minor weight Weight under zero Zero symbols Weight is at zero point Low battery Battery need to charge or replaced Weight minor Zero Low Battery 6 INSTALLATION A ATTENTION ONLY FOR COLUMN SCALE After removing the instruments from the packing check the integrity and right contents Put the scale far from souce from of heat e vibration Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL Put the scale on stable surface Assembly Assembling column to the platform Connecting wire between column and platform first Flip the scale platform on the bench Fix with 4 screw the column at the platform Place to the ground the scale and adjust the 5 adjustable feet For use connect the external power supply with the electric current 7 ISTRUCTION FOR USE 7 1Time setting Long press PRINT key for 3 seconds to enter the TIME SETTING mode beginning wit
15. ndications concerning OPERATING SAFETY AND MAINTENANCE The descriptions and illustrations supplied in this manual are not binding WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being committed to update this publication Conventions The following symbols have been used in this manual CE 0470 MEDICAL CERTIFICATION M METROLOGICAL CERTIFICATION AND APPROVAL FOR MEDICAL USE AID ACCURACY CLASS E 5 a ASSISTANCE WARRANTY CERTIFICATE ATTENTION PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN DAMAGE THE PRODUCT PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN HARM THE OPERATOR OR PATIENT OR DAMAGE A WARNING A THE PRODUCT WASTE DISPOSAL BATTERY POWER TYPE B PARTS SUPPLIED v INDICATION OF WEIGHT FUNCTIONALITY INDICATION OF STABLE WEIGHT INTERFERENCE COULD OCCUR NEAR THE APPLIANCES E DUAL INSULATION 3 SAFETY A WARNINGS Operators must read this manual carefully comply with the instructions it contains and become familiar with the correct use and maintenance procedures of the instrument e Retain this manual for consultation and as a help in staff training Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com vV e Do not apply loads abruptly ETEK Do not overload the instrument beyond its maximum capacity USER MANUAL e Do not
16. ng and try E y E The total load exceeds the maximum again capacity of scale Counting error too high This error is normally caused by a E H Indicates that the signal from the load rr cell s is too height Counting error too low E He Indicates that the signal from the load F f cell s is too low rm re ce ce a Zero count over calibration zero range Please re calibrate the instrument serious fault on the scales such asa faulty load cell or wiring Please contact the local service representative This error is normally caused by a serious fault on the scales such asa faulty load cell or wiring Please contact the local service representative 1020 while power on Zero count under calibration zero Please re calibrate the instrument ETT range 10 while power on EEPROM Error This error is normally caused by a E r r P Indicates that there is a fault with the serious fault on the scales such asa scales software faulty load cell or wiring Please contact the local service representative 11 MAINTENANCE AND ASSISTANCE For better and longer duration of the product it should receive thorough general cleaning periodically The instrument must be cleaned with a soft cloth moistened with water or neutral detergent without using solvents or abrasive substances If the instrument remains idle for a long period remove the batteries from the terminal During shipping mak
17. s for this purpose Even when scrapping electric and electronic appliances they must be removed and deposited in specific collectors NOTE The following symbols indicate the presence of harmful substances Pb Pb batteries containing Lead Cd Cd batteries containing Cadmium Hg Hg Batteries containing Mercury A ATTENTION Do not throw electric parts and used batteries away with household waste Dispose of the batteries by means of your closest collection centres 15 WARRANTY Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 11 VETEK USER MANUAL This certificate must be kept until the warranty has expired It must be presented together with the invoice tax receipt or delivery note providing the name of the dealer and date of purchase whenever a technical intervention is required Otherwise the user will lose any warranty rights The warranty takes effect from the date of purchase and is valid during the entire period foreseen by the current catalogue pricelist By warranty we mean the replacement or repair free of charge of parts making up the appliance which at the discretion of the manufacturer are deemed faulty from the origin Wunder therefore has the faculty of repairing or replacing the item The warranty does not cover e shipping faults damage caused by falls carelessness or tampering e damage caused by incapability of using the appliance and o
18. t meter side view metal support 2 Black abs support height meter 3 Screws N 02 screws T E N 02 slotted screws N 01 Allen Screws N 02 nuets 5 N 02 washers 5 M5x16 M5x25 M6x12 4 Tools Allen tools Picture 2 2a behind the pole column assemble the white metal support with screws B Picture 2b the position is on the right Picture 3 3a assemble the height rod on black abs support with screws C and allen tools kit Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 13 VETEK USER MANUAL Picture 3b The height rodi s ready for use Pull up the height meter rod Press the black button and measuring height and push down Position it horizontally Lower the rod up to the point where the lever rests head Position it horizontally touches the patient s head The height can be read at the point A Lower the rod up to the point in which the blade rests head touches the patient s head The height can be read at point B Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 14 VETEK USER MANUAL 17 THERMAL PRINTER OPTIONAL A Read this manual carefully before using the instrument Platen Rollen Roll Holder 17 1 HOW TO USE YOUR PRINTER Connect the AC Adaptor and RS232 interface cable Press the I O