Home
User Manual DCS 6000 Conference Units rev L
Contents
1. User Manual SYSTEM MOGES ceivesntavivsvevavscenearscivnerec 27 Individual modes only with SW 6000 28 Language Selection functionality 29 User Controls amp Indications 8 29 Headphone Connectors ccecceeeeseeeeeees 29 Normal Operation ccccceeeeeeeeeeeeeeees 29 Voting functionality sssssssss222 30 User Controls amp Indications 08 30 Normal operation ccccccseeseeeeeeeeeeeeenes 30 Chip Card functionality ssssscceeeeees 31 The use of Chip Cards ccccccuueesseeueenns 31 User Controls amp Indications 8 31 System Setup creissien aaa 32 DCS LAN connector ssssssss2 32 General guidelines sssssss22222 32 SENGS eian a a Gonmrdctn ait 32 Electrical termination of DCS LAN Network32 Typical schematics ssssssssesennnrrrrrerrnrn 32 Starting up the system ccceeeeeeeeeeeeees 32 Adjusting LCD contrast on units with channel Selector roroi 32 ACCESSONIES ian 34 Technical SpecificationS s s s 22 36 System Specification s sss222 2 36 Connection Details sssssss22 2 37 A CCOCSSOMIGS siniviticinacewicawawacecscavewicewawaecs 37 User Manual DCS 6000 Conference Units rev L docx DIS Digital Conference System Important Installation precautions Do not install the unit in a location near heat sources such as radiators or air ducts or in a place
2. 19 DCS 6000 Digital Conference System User Manual Unit Type Unit Type Delegate Unit Chairman Unit Dual Delegate Unit The Unit Type menu gives access to changing the unit type by selecting the desired unit type and exiting the menu The unit will reboot when the unit type is being changed Unit type screen Left Btn Left Button The Left Btn menu gives access to changing the functionality of the left push button by selecting the desired function and exiting the menu The unit will reboot when the left button functionality is being changed Mute Mute All All Del Off Next On Exclusive Left Btn screen Comm Stat Communication Status Rx Errors Tx Retries Tx Dropped Tx Denied Poll Denied The Comm Stat menu gives access to an overview of the communication errors The counters should be 0 though the Tx Retries may increase slightly during start up and if two delegates press their speak button simultaneously Comm Stat screen Unit Status X Unit Status Back The Unit Status menu gives access to an overview of the serial number plus current firmware versions of the unit Serial Number 000 238 056 Mic App Version 63 01 Gui Version 63 07 Dsp Version Rootfs Version 62 50 Unit Status screen 20 DCS 6000 Digital Conference System User Manual Tee Deseroton etre Languages Enable Lang Disable Lang Languages screen Languages The Languages menu enables the user to
3. 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email info shure de Asia Pacific Shure Asia Limited 22 F 625 King s Road North Point Island East Hong Kong Phone 852 2893 4290 Fax 852 2893 4055 Email info shure com hk
4. Results Results Logout DM SW 6000 Agenda Results Messages Logout Dual DM stand alone Results Results Audio Messages Logout i A Dual DM SW 6000 Agenda Results Kem Messages Logout a DM and Dual DM Menu screen SW 6000 14 DCS 6000 Digital Conference System User Manual La asic inci EE Conference menu Conference Sales seminar The Conference menu displays the available Technical product presentat conferences on a list form The CM can start and stop Budget forecast 2010 Sales training a conference using the start stop conference button Marketing activities 200 Ai start Conf Conference menu start conference Conference Sales seminar Technical product presentat Budget forecast 2010 Sales training Marketing activites 2009 2 Stop Conf Conference menu stop conference Voting menu Voting Parameters The Voting menu displays the available voting eee ae parameters In stand alone four parameters are pee ci available while with the SW 6000 all the parameters 5 Button Secret defined in the CAA will be available The CM can scroll in the list using the scroll buttons and start a selected voting session or attendance check Attendance Cancel Start Voting i a EE Voting Parameters 3 button 3 button attendance check 3 button quorum 3 button secret 5 button Cancel Start Voting 15 DCS 6000 Digital Conference Syst
5. exposed to direct sunlight excessive dust or humidity mechanical vibration or shock Electrostatic discharge may cause the following conference units to restart If such events occur the conference units will self recover e DM 6680 P e DM 6680 F e DM 6588 F Compliance The equipment is intended to be used in professional audio applications Note This device is not intended to be connected directly to a public internet network EMC conformance to Environment E2 Commercial and Light Industrial Testing is based on the use of supplied and recommended cable types The use of other than shielded screened cable types may degrade EMC performance Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate this equipment This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Authorized under the verification provision of FCC Part 15B Please follow your regional recycling scheme for batteries packaging and electronic waste Information to the user This equipment has been tested and found to comply with the limits for a Class B digital device User Manual DM 6080 F DM 6620 F DM 6501 F CM 6080 F CM 6680 F To avoid moisture condensations do not install the units where the temperature may rise rapidly To avoid moisture condensations do not install the unit where the
6. where the delegate can listen to either the floor spoken language or an interpreted language User Controls amp Indications The units featuring language selection will include on or two sets of the following controls and interfaces Display This display is used for information purposes This display has built in back light Channel buttons two The buttons are used for changing the channel setting Volume buttons two The buttons are used for changing the volume setting Headphone Connectors Headphone Connector mini jack A mini jack located on the front plate for connecting a headphone for listening to the floor language or one of the interpreted languages Dual headphone Connectors mini jack Some units are supplied with two mini jacks located on the front plate for connecting a headphone for listening to the floor language or one of the interpreted languages Automatic Use CU Mode a Headphone Connector Molex only F models A 2 pin Molex jack is located at the back for connecting a headphone for listening to the Floor language or one of the interpreted languages on the following models CM DM 6080F CM DM 6680F DM 6620F DM 6588F This connecter is intended for use where the connection to the headphone is remotely from the front plate which is only on customised units Important The 2 pin Molex jack is for professional use only Normal Operation Channel Selection
7. Carefully insert the tip of adjustment tool into the adjustment hole until the tip of the tool makes contact lock with the potentiometer located behind the hole see photo 3 and 4 Potentiometer 6 Turn the adjustment tool until the required contrast setting is obtained Do not use excessive force when turning the tool as this will cause the potentiometer to be damaged Carefully extract the adjustment tool from the adjustment hole 33 DCS 6000 Digital Conference System Accessories User Manual The following accessories are available for use with the DCS 6000 Conference Units Art no Description Illustration GM 6523 Gooseneck Microphones with XLR GM 6524 plug GM 6524 The gooseneck microphones are available in various lengths To be connected to the XLR microphone connector GM 6523 Gooseneck mic 40 cm GM 6524 Gooseneck mic 50 cm GM 6525 Gooseneck mic 63 cm BM 6620 Boundary Microphone HM 4042 Hand Microphone with light ring The HM 4042 Hand Microphone is designed for use with the MU 6040 C D unit The microphone is equipped with ON OFF button light ring as well as an indicator With an extension cable the microphone can be connected to the MU 6040 to the HD15S connector or to the XLR connector on portable units If connected to the XLR connector the ON OFF button as well as the indicator is not functioning This indicator lights red when the microphone is ON and green when
8. Parliamentary Voting and Agenda or by using the DC 6990P The various voting modes and voting functionality in general is explained in the SW 6000 CAA User Manual and in the DC 6990P section However the functionality directly related to the Control amp Indications in the units is explained here User Controls amp Indications The units featuring voting functionality will include the following controls and interfaces Yes Present button Pressing this button casts a Yes vote or show the user as Present to the system Abstain 0 button Pressing this button casts a Abstain vote No button Pressing this button casts a no vote Yes Present LED This yellow LED flashes alone when the user have to present himself to the system as Present When User Manual and the step size in dB between successive levels is globally defined using system parameters however setting the volume level to O turns the headphone line output off When a volume button is depressed the channel display will be overridden with the current volume this is indicated by the black dot in the upper left corner of the display if the show volume global parameter is set The display will continue to show the current volume level for a preset time interval before returning to displaying the channel information this time interval is also set globally using a system parameter the LED flashes together w
9. Power requirement ssssssrerssnansenasnernsnana 24 48 V DC Power CONSUMPTION vivinutaseuwckandutvas ca varaueamenoes 1W 3W User Manual Power supplied from CU 61xx EX 6010 PS 600x Temperature to guarantee specified performance EEE 5 Deg C to 40 Deg C 35 to 80 humidity Storage temperature PAIE 20 Deg C to 60 Deg C 10 to 80 humidity Connectors DCS LAN loop through sseeeeeeeeeees 2 pieces RJ45 Specifications are subject to change without notice 36 DCS 6000 Digital Conference System Connection Details DCS LAN Chain The DCS 6000 system uses shielded Cat5e Cat6 or Cat7 F UTP or U FTP cables with shielded RJ45 connectors EIA 568 B wiring shall be used Important The names of Cat5 6 7 cable type have changed Important Use only F UTP or U FTP shielded cables and shielded RJ45 connectors and not U UTP cable which are unshielded How to wire a Cat5e EIA 568 B cable to a RJ45 con ass Connector 1 Connector 2 ORG WHT ORG WHT GRN WHT GRN WHT BLU WHT BLU WHT BRN WHT BRN WHT stommer ean Torn Important If other color codes are used then the four pairs are connected as follows Pair 2 Pinl amp 2 Pair 3 Pin3 amp 6 Pair 1 Pin4 amp 5 Pair 4 Pin7 amp 8 User Manual Note Cat6 and Cat7 cables can normally only be terminated in sockets female and not in cable plugs Cat6 and Cat7 can thus only be used for feeding cables terminating in wall outlets or pa
10. about cabling and maximum number of units to connect to the DCS 6000 system please consult the CU 61xx User Manual Settings There are no settings to be done on the DCS 6000 conference units The units are automatically recognized and receive a unique address in the system when connected to the unique DIS digital communication bus the DCS LAN Electrical termination of DCS LAN Network Before powering up your DCS 6000 system you must ensure that the DCS LAN Network has been properly terminated If the last unit in a chain is a CS 6032F the unit must have a DCS LAN Network Termination Plug inserted in one of the two DCS LAN Network connectors RJ45 connectors If the network is not terminated properly communication errors on the network may occur resulting in malfunction or degradation of the system performance User Manual e Maximum cable length in one chain is 200 m without repeater This includes interconnection cables between the units The max usable cable length depends on the units connected and length of feeding cables etc e Maximum cable length in one chain when using repeaters is 650 m If the last unit in one chain is a CS 6032 Channel Selector this unit has to be terminated with an external termination as the CS 6032 does not have an internal termination 4 pcs of DCS LAN Network Termination Plug have been shipped with your DCS 6000 Central Unit Typical schematics Please consult the CU 61xx Use
11. e g in an armrest under a table or in a floor box for use with the FD FC series of front plates with Loudspeaker Microphone and Buttons Note The MU 6042D does not support the use of the HM 4042 Hand Microphone The MU 6042D is provided with a HD 15S connector for connection of the FD FC front plate for use with two delegates like FD 6012F featuring Mic On Off Request buttons for two delegates Note The MU 6042D operates in the same modes as the other units except for the VOX mode 23 User Manual DCS 6000 Digital Conference System User Manual e Deseption ration AM 6040 Ambient Microphone The AM 6040 Ambient Microphone Unit is designed to detect ambient noise in a conference room The purpose of an ambient microphone is to provide sound from a meeting room conference hall when there is no speaker chairman active using their microphones The microphone should be placed in a central position in the room but not too close to anyone thereby the microphone is able to pick up sound from activities in the room hall chairs being moved paper being picked up low voices and so on Transmission of ambient noise rather than transmitting no sound at all is a desirable feature from listeners attending the meeting via headphones The ambient noise indicates to the listeners that there is no speaking activity going on and this information is very nice to have when interpreters are doing interpretation and the speaker s
12. expanded with a PC running SW 6000 Conference Management software with the module SW 6070 Chip Card Login The functionality in general is explained in the SW 6000 CAA User Manual However the functionality directly related to the Control amp Indications in the units is explained here The use of Chip Cards This Chip Cards in use are delivered from DIS with options for programming the following information onto the cards Location ID This is an ID related to the location of the installation The location ID prevents the card to be used at other locations All cards for one installation shall have the same location ID The location ID has to be entered in the Setup Equipment Chip Card menu in the SW 6000 CAA application Delegate ID This ID is used to identify the user in the Delegate database in SW 6000 Each card must have a unique ID 1 2 3 etc The information for each delegate in Delegate in the SW 6000 CAA application will also have a unique Delegate ID corresponding to the cards When a card is inserted in a conference unit the software will identify the user by matching the Delegate ID in the Delegate database with the Delegate ID on the card User Manual Login code This is the password used to log the user into the system User Controls amp Indications The units featuring chip card functionality will include the following controls and interfac
13. in request DH 6001H Delegate Headphone This headphone is used with the built in channel selector in flush mounted units To be connected to the headphone connector 34 DCS 6000 Digital Conference System User Manual Art no Description Illustration DH 6021 Delegate Stereo Headphone This headphone is used with the DR 600x Receiver DC 61xxP DM 6680P and DC 6990P To be connected to the headphone connector CC 6010 Chip Card Chip card to use with Chip Card reader JB 6104 Junction Box SUmAayshg YON osdsoquy YSTUCG qi EC 6001 xx Cat 5e Connection Cables AWG24 The EC 6000 series cables are used to connect the various units in the DCS 6000 system using the DCS LAN connector Type EC 6001 5 Connection Cable 0 5 m EC 6001 01 Connection Cable 1 m EC 6001 02 Connection Cable 2 m EC 6001 05 Connection Cable 5 m EC 6001 10 Connection Cable 10 m EC 6001 20 Connection Cable 20 m EC 6001 30 Connection Cable 20 m EC 6001 50 Connection Cable 50 m CO 6000 RJ45 terminator DCS LAN Termination plug 35 DCS 6000 Digital Conference System Technical Specifications System Specification Digital Section Sound quality 20 bit audio 32 kHz sampling frequency Analog Section Frequency reSpOonSe s ssssrersssanronssnenrsenannn 125 15kHz Signal tO NOISE FAtIO arero a gt 85 dBA Total harmonic distortion cece eeeeee ee eee lt 0 1 General
14. is reached the next delegate pressing the ON OFF button will be put in the top of the request queue The green Request lamp flashing indicates this More delegates will be put in the request queue when they press their ON OFF buttons until the maximum of requests is reached Their green Request lamps will light up steadily When one of the active microphone units is switched off the first delegate unit in the queue is automatically switched ON and the next delegate unit in the queue will flash with the green Request lamp This mode will normally be used with only 1 as maximum speakers Microphones with Chairman priority will always be turned on directly Manual Manual mode features a request list where Delegates are inserted in a queue upon pressing the microphone ON OFF button This is confirmed by green light in the Request lamp in the delegate unit It is possible to cancel the request by pressing the button again The microphone can only be switched on from a PC running SW 6000 software from the DC 6990 Chairman unit or from a control system like AMX or Crestron This will be indicated by red light in the Speak lamp in the microphone unit At this point the delegate can switch off the microphone by pressing the ON OFF microphone button Microphones with Chairman priority will always be turned on directly VOX VOX voice activation mode allows for the microphone units to be switched on au
15. temperature may rise rapidly pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment to an outlet on a circuit different from that to which the e receiver is connected e Consult the dealer or an experienced radio TV technician for help DIS Digital Conference System Cleaning To keep the cabinet in its original condition periodically clean it with a soft cloth Stubborn stains may be removed with a cloth lightly Repacking Save the original shipping cardboard box and packing material they will become handy if you ever have to ship the unit For maximum protection Warranty The individual units in the DCS 6000 system are minimum covered by 24 months warranty ag
16. Channel selection is done using the channel up and channel down buttons Channel numbers can be from O to 31 however the indication in the display is abbreviations of the language selected i e ENG for English SWE for Swedish The lowest channel O FLO always carries floor audio and all other channels carry interpreted languages or floor if no interpretation is currently performed on this channel If fewer than 32 channels are in use only available channels will be selectable from the channel selector the channels are always numbered consecutively Pressing the down button when 29 DCS 6000 Digital Conference System the lowest channel number is displayed will cause the channel selection to wrap around to the highest available channel if the channel wrap parameter is Set Holding the channel up or down button depressed will cause the channel numbers to scroll with a system defined start up delay and subsequent smaller delay between each change in channel position These delays are set using system parameters Volume Control Volume control is done using the volume up and volume down buttons The number of volume levels Voting functionality Voting functionality is a feature where delegates can cast their votes to various subjects using the DCS 6000 Conference Units The voting functionality is only available when the system if expanded with a PC running SW 6000 Conference Management software with the module SW 6060
17. SHURE LEGENDARY PERFORMANCE Conferencing and Discussion Systems DCS 6000 Conference Units USER GUIDE y d 2015 Shure Incorporated User Manual DCS 6000 Conference Units rev L docx DCS 6000 Digital Conference System Table of Contents Table of Contents cccesseeeeeseeeeeeeeeeeeeeees 2 MDO CAIN sesser aO coasanescs 3 Installation precautions sssssussss 3 COMPNANGCC rirerire a 3 Information to the USer ssssssssssssssrssrssens 3 Cleaning oen 4 Repack R 4 Warranty csissisrakinis aini aiaa 4 Your DCS 6000 Conference System 5 The DCS 6000 system sssssssss22 5 System COMPONe NES ssss22 2 6 Central equipment etC c cc ecceeeseeneenneeees 6 Interpreter EQUIDMENL cece eee eee eee 6 Conference units and Ch selectors 6 PCCE SS ON CS uinn a 6 Operating instructiOnS ssss 2 7 DCS 6000 Conference Units scccssseees 7 General description ccccceeeeeerseeeeenees 7 POOLING S uono aea AANA 7 Conference Units description 85 7 Portable conference UNItS ccccceeeeeeeeees 8 Flush mounted conference units 21 Microphone functionality cccseesseeees 25 User Controls amp Indications 25 Microphone CONNECTIONS ceeeeeeeeeeeeee 25 Locking of the Microphone 0005 25 Operation MOS cssscscccennnneeescecnnnneseees 27 2015 Shure Incorporated
18. ainst defects in materials or workmanship User Manual dampened with a mild detergent solution Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet re pack the unit as originally packed from the factory DCS 6000 Digital Conference System User Manual Your DCS 6000 Conference System The DCS 6000 system DCS 6000 Digital Conference System is a system to be used at meetings where a number of people are addressing the Floor in a structured manor The audio from the Conference units can be heard in the built in loudspeakers in the units The system does also allow for simultaneous interpretation for international conferences where multiple languages are used To enable all participants to understand the proceedings interpreters can simultaneously translate the speaker s language as required These interpretations are distributed through the connected Conference units and delegates can select the language of their choice and listen to it through headphones DCS 6000 Digital Conference System comprises of one CU 61xx Central Unit and a number of Conference Units Gooseneck Microphones and other accessories depending on the system configuration The DCS 6000 system has the following main features e Fully digital e Excellent sound quality e State of the Art fully digital integrated interpretation discussion and voting system offering interpretation langua
19. al Conference System When locked the microphone cannot be removed from the unit FD 61x0 FC 60x0 Front Plates Locking Turn clockwise Un locking Turn counter clockwise 26 DC 6990P DC 61x0P og DM 6680P Locking Turn counter clockwise Un locking Turn clockwise User Manual DCS 6000 Digital Conference System User Manual Operation modes System modes The following modes are available when the CU 61xx runs standalone PC with SW 6000 has The 6000 series microphones work in different never been connected modes according to the settings of the system The System Operation Mode also called CU mode determines the behaviour of the microphone system The mode is set on the CU 61xx Automatic Auto or Automatic mode allows for the microphone units to be switched on immediately upon pressing the microphone ON OFF button This is indicated by a red light in the Speak lamp in the microphone unit Pressing the microphone ON OFF button again will turn the microphone off If the maximum speakers delegates is reached the speak request will be rejected Microphones with Chairman priority will always be turned on a Chairman Unit is always in Auto or VOX mode FIFO FIFO is an automated mode The microphone unit functions in the same way as in automatic mode as long as the number of turned on delegate units is less or equal to the selected maximum speakers When the maximum number
20. ber of speakers is reached The key is as follows Use CU mode Not allowed Cannot interrupt another speaker Interrupt setting lt Can interrupt a speaker with the same speak priority or a speak priority which is less than own speak priority lt Can interrupt a speaker with a speak priority less than own speak priority For most installations the Operation Mode for all running in Manual mode the Delegates Units will units is set to use the system mode Use CU mode run in Manual mode It means that the operation mode for the units is following the system modes i e if the system is When assigning units to run Use CU modes the modes are found in the following table Operation mode Speak priority Interrupt ability Chairman fawomate Se Delegate Use CU mode Use CU mode 28 DCS 6000 Digital Conference System However for certain application it is desirable to assign individual operations mode where the units will always follow the individual mode settings independently of the System Setting User Manual I e the following Units can be created No Speaking Rights poes rot mater 0 Does not matter Delegate FIFO This unit will interrupts other delegates if the Maximum speaker are reached Speaker stand This unit can always turn on except if 8 units with Speak priority 5 is open Language Selection functionality Language selection is a feature
21. e Units offers full compatibility with the DCS 6000 Digital Conference System with the CU 61xx amp EX 6010 Central and Extension Units Features The Conference Units offers i e the following features the features depends on the version e XRL socket for detachable microphone User Manual Speak button Function button Built in loudspeaker Language selector Voting Chip Card reader Touch screen Conference Units description The conference units are delivered in Chairman CM version Delegate DM version or DC configurable version and in Portable and Flush Mounted versions DCS 6000 Digital Conference System Portable conference units Type DC 6120P Portable Conference Unit Configurable as CM and DM Lockable XLR microphone connector Loudspeaker Mute all del off and speak request buttons Headphone connector and volume control for floor channel The unit can be configured either as a chairman or a delegate unit The unit comes per default with a delegate configuration To configure the unit the mute and the microphone button must be kept down while pressing the volume up button for 10 seconds for chairman functionality or the volume down button for delegate functionality The button light guides will flash when the unit is configured and the unit will reboot The configuration is stored in the unit so it recalls its configuration if it is used in another system setup The left button is a f
22. e button is activated Microphone light ring Lights up with a red colour when the microphone is ON If the microphone is muted the light in the light ring is turned off during the time the unit is muted Microphone connections XLR microphone connector The XLR microphone connector is used for connection of GM 652x series of gooseneck microphones The HM 4042 Hand Microphone can also be connected However the button on the hand microphone will not work Mini DIN microphone connector only F models A Mini DIN microphone connector is located at the back for connection of FD FC front plates with GM 65xx F series of gooseneck microphones The HM 4042 Hand Microphone can also be connected This connecter is intended for use where the connection to the microphone is remotely from the front plate which is only on customised units HD 15S connector only MU 604x models The HD 15S is used for direct remote connection of FD FC series of front plates or Microphones e g HM 4042 or GM 652x in external outlet or and microphone control buttons LED indicators and loudspeaker Please refer to the technical section for pin layout Important The microphone input at the above mentioned connectors does only support DIS microphones and do not support other types of microphones i e third part microphones Locking of the Microphone The following units features locking of the microphone using a tool 25 DCS 6000 Digit
23. e unit will reboot The configuration is stored in the unit so it recalls its configuration if it is used in another system setup The left button is a function button that changes functionality depending on the configuration The chairman configuration enables all delegates off functionality in the left button while the delegate configuration enables mute and reply functionality in the left button The function button can be changed to match the current functionality by pushing the button out of the unit from below The new button is then simply clicked into the unit The gooseneck microphone GM 652x can be locked to the unit with a 1 5 mm hex key The lock is accessible from the small hole below the DIS logo on the side of the XLR socket Turn the hex key counter clockwise to lock the gooseneck microphone to the unit and turn the hex key clockwise to unlock the gooseneck microphone from the unit User Manual DCS 6000 Digital Conference System User Manual Twee Description Bustration DM 6680P Portable Delegate Conference Unit Lockable XLR microphone connector Loudspeaker Speak request button and Function button Chip card reader Channel selector 2 headphone connectors Exchangeable buttons and button overlays The unit comes with two standard button overlays The overlay to be used can be attached to the unit by removing the paper on the back of the overlay and fixing the overlay to the unit Overlays w
24. em User Manual La cis dna EE Agenda menu Agenda l Agenda The Agenda menu displays the agenda for an active Review of last year s results conference The agenda is created in the CAA aie The CM can set a subject on the agenda and start a Arton P A voting session or attendance check by using the Set Marketin ee Subject and Start Voting buttons i l By pressing the Details button the full agenda subject will be displayed Agenda Agenda Review of last year s results Sales strategy SWOT Action plan 2010 2011 Financial plan Marketing strategy No Subject Details Start Voting R Its men Voting Results esults il No Subject The Results menu displays the latest voting or attendance check result Yes Abstain 2 3 Start Voting R Voting Results Sales strategy DM Results menu SW 6000 16 DCS 6000 Digital Conference System User Manual Attendance Check Result P S Present 3 AudioA AudioB Dual DM Results menu SW 6000 Audio menu Volume The Audio menu contains volume and channel T settings for the channel selector antl Channel 0 FLR Audio menu Messages menu Message Received Messages 3 The Messages menu contains messages that are sent z Coffee break in 15 minutes to the unit from a CUA SW 6000 You are the next speaker j Please turn off your mobile By pressing the Read button the selected message 4 opens u
25. enable the pe went A languages that should be available as user interface BEN enn language The user must logout and login again to ENU English United States see the changes Flush mounted conference units Te Beserntion ration Chairman Front Plate Unit Lockable XLR microphone connector Speak request button Delegates off button HD 15 P connector for connection to MU 4040 MU6040C The gooseneck microphone GM 652x or GM 6622 can be locked to the unit with a 2 mm hex key The lock is accessible from the small hole above the XLR socket Turn the hex key clockwise to lock the gooseneck microphone to the unit and turn the hex key counter clockwise to unlock the gooseneck microphone from the unit Chairman Front Plate Unit Lockable XLR microphone connector Loudspeaker Speak request button Delegates off button HD 15 P connector for connection to MU 4040 MU6040C The gooseneck microphone GM 652x or GM 6622 can be locked to the unit with a 2 mm hex key The lock is accessible from the small hole above the XLR socket Turn the hex key clockwise to lock the gooseneck microphone to the unit and turn the hex key counter clockwise to unlock the gooseneck microphone from the unit 21 DCS 6000 Digital Conference System User Manual e Deserption tration Delegate Front Plate Unit Lockable XLR microphone connector Loudspeaker Speak request button Mute button HD 15 P connector for connection to MU 4040 MU6040D The go
26. equest list on the remaining requests on the request list and on any speaker on the speaker list respectively Main screen When the user leaves the start up screen the main screen appears It includes a combined speaker and request list with 13 Please insert valid Chip Card me Cancel Wi d Login using chip card Please enter code Login using code Bent Nielsen Conn Larsen Carsten Nielsen Mette Andersen Vatia Jensen AllReq Off Exclusive CM Main screen DCS 6000 Digital Conference System User Manual ETT ac a The DM includes an audio button e Audio Please refer to the section Audio menu for more information DM Main screen The Dual DM includes two audio buttons e Audio A selection button for Delegate A e Audio B selection button for Delegate B Please refer to the section Audio menu for more information Audio A Dual DM Main screen 7 Menu screen Conference q Voting D When the user presses the Menu button the menu lt yr N i 7 See i screen with a menu overview appears The overview ED CEOD gives access to extended functionality depending on whether it is running stand alone or with the SW 6000 user type dependant i f N Audio Messages P N Logout D CM stand alone Voting Results Audio ie ae Logout CM SW 6000 Conference Voting Agenda Results Audio Messages Logout DM stand alone
27. es Chip Card reader The Chip Card reader is used together with the DIS Chip Cards for identifying a user to the system The Chip Card reader and Chip Cards can only be used together with the SW 6000 software When in use the Chip Card is inserted in the chip card reader Chip Card LED This LED lights yellow if it is required to insert the Chip Card with the exception of the DC 6990P that does not have an LED When inserted the LED lights RED if the card is not accepted and lights GREEN if the card is accepted 31 DCS 6000 Digital Conference System system Setup DCS LAN connector In addition to the connectors mentioned in the previous section the following connectors are available on all units Two RJ45 sockets are located at the back of the units for connecting to the previous unit an IS 6132 Interpreter set CS 6032 Channel Selector DM 6xxx Delegate Unit DC 6990 P Conference Unit the CU 61xx Central Unit or any other unit with a DCS LAN connector and to the next unit Connect the units using Cat 5 FTP or STP cables Please observe the following guide lines General guidelines Connect the DCS 6000 Conference Units at the DIS LAN connectors to the various units using Cat 5e FTP or STP screened cables Please observe the following guidelines e Maximum cable length in one chain when not using repeaters is 200 m e Maximum cable length in one chain when using repeaters is 650 m For more details
28. ge distribution conference microphone and voting facilities with attendance check with Chip Card e Digital transmission of audio from to the Conference unit to from the central unit using a unique digital DATA and AUDIO bus named DCS LAN e Control of up to 3800 conference units This number does not include Channel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system e Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit which drives up to app 50 units with the PS CU power Supply e EX 6010 Extension Unit or PS 6001 DCS LAN Power Kit is available if more units are required e Delayed switching on of power to the two DCS LAN chains to minimize the total in rush current on the Mains supply e Designed for 31 interpretation channels and 8 open microphones e Audio scrambling of the audio to avoid eavesdropping e Designed in a standard 1HE 19 cabinet e TCP IP connection on CU 61xx for external operation of the system using a PC or control system such as AMX or Crestron e Functionality on the CU 61xx depends on the Feature License uploaded into the unit e Firmware in Delegate units Interpreter Units Central Units etc is upgradeable e Operated either stand alone or from a PC using the CU browser or using SW 6000 software e Added functionality and comprehensive features provided by SW 6000 software package ru
29. ith other functionality and in other languages can be ordered as custom overlays The mute and speak request buttons can be changed to match the local language Remove the plastic caps underneath the unit and insert a thin device to eject the buttons from underneath Insert the new button by clicking it into the unit Insert the plastic caps after changing the button s The gooseneck microphone GM 652x can be locked to the unit with a 1 5 mm hex key The lock is accessible from the small hole to the left of the XLR socket Turn the hex key counter clockwise to lock the gooseneck microphone to the unit and turn the hex key clockwise to unlock the gooseneck microphone from the unit The unit can be fixed to the table top using the mounting holes on the underneath of the unit Drill a hole maximum 10mm deep using an 2 5mm drill and use a bottoming tap M3x0 5 to cut a thread Fasten the unit from below the table with a long screw that fits with the dimension of the screw hole 10 DCS 6000 Digital Conference System User Manual The unit has five buttons that change functionality depending on the system status During normal operation the two buttons to the left change the interpretation channels while the two buttons to the right change the volume of the channel selector During voting sessions the buttons act as voting buttons whether it is a 3 button or 5 button voting session taking place The voting sessions can be
30. ith the two other voting LED s the user can press any of the voting buttons to cast a vote Abstain 0 LED When the LED flashes together with the two other voting LED s the user can press any of the voting buttons to cast a vote No LED When the LED flashes together with the two other voting LED s the user can press any of the voting buttons to cast a vote Normal operation Attendance check When the yellow Yes Present LED flashes alone the user can to present him to the system as Present by pressing the Yes Present button Cast a vote When all the yellow voting LED s flashes the user can cast his vote by pressing any of the three voting buttons The user can cast his vote or change a vote as long time as the voting session is on going If the voting parameter is selected as Secret done in the SW 6000 the LED s stop flashing after the vote is caste however the user can still change his vote if needed 30 DCS 6000 Digital Conference System Chip Card functionality Chip Card functionality is a feature where delegates identify themselves to the system by use of a DIS chip card The Chip Card contains information like Delegate ID Login Code and Location ID which the DCS 6000 system uses to identify the user of the Conference Unit by getting the personal details from the database in the SW 6000 The Chip Card functionality is only available when the system if
31. nning on PC The SW 6000 is an optional software package which expands the functionality of the DCS 6000 system The software runs on standard computer technology Standard PC with Windows 7 Server 2008 etc Main features of the SW 6000 are e Microphone management e Mimic panel operation e Interpretation management e Voting management e Message handling e Agenda handling e Data stored on SQL data base e Web service interface available for easy links to external applications e Multi language user interfaces e Supports different User types with different priorities user interfaces and control possibilities DCS 6000 Digital Conference System System components Central equipment etc CU 6105 Central Unit CU 6110 Central Unit EX 6010 Extension Unit PS 6001 DCS LAN Power Kit consisting of one PS CU and one PI 6000 PS CU Power Supply PI 6000 DCS LAN Power Inserter RC 6000 Redundancy Controller AO 6004 Audio Output Unit AO 6008 Audio Output Unit RP 6004 Repeater for four chains JB 6104 Junction Box with 4 outputs Interpreter equipment IS 6132 P LS 6132 P Interpreter Unit Interpreter Loudspeaker Conference units and Ch selectors DC 6990 P Conference Unit portable with touch screen with two built in channel selector Chip card and 5 voting buttons configurable as Delegate Dual Delegate or Chairman Conference Unit portable Conference Unit portable with two built in channel selector
32. oseneck microphone GM 652x or GM 6622 can be locked to the unit with a 2 mm hex key The lock is accessible from the small hole above the XLR socket Turn the hex key clockwise to lock the gooseneck microphone to the unit and turn the hex key counter clockwise to unlock the gooseneck microphone from the unit Delegate Front Plate Unit Lockable XLR microphone connector Speak request button Mute button HD 15 P connector for connection to MU 4040 MU6040D The gooseneck microphone GM 652x or GM 6622 can be locked to the unit with a 2 mm hex key The lock is accessible from the small hole above the XLR socket Turn the hex key clockwise to lock the gooseneck microphone to the unit and turn the hex key counter clockwise to unlock the gooseneck microphone from the unit Flush Mounted Conference Unit Lockable XLR socket for DIS gooseneck microphone DM 6080F Speak request button CM 6080F Push to talk priority button CM 6080F Delegate Off button with LED indication Loudspeaker Headphone connector Channel selector The connectors on the back on the unit located on the PCB is for professional use only Flush Mounted Conference Unit Lockable XLR socket for DIS gooseneck microphone DM 6680F Speak request button CM 6680F Push to talk priority button CM 6680F Delegate Off button with LED indication Loudspeaker Channel selector Headphone connector 5 voting buttons Chip card reade
33. p By pressing the Delete button the selected message is being deleted Messages menu Logout menu The Logout menu allows the user to logout and return You are aboutto ease to the Start up screen Do you want to continue Ok Cancel Logout menu 17 DCS 6000 Digital Conference System User Manual Voting Sales strategy T John Hansen The Voting screen is automatically displayed on all units when a voting session or attendance check is started Users with voting right can cast their vote Yes Abstain Cancel Sales strategy John Hansen Sales strategy John Hansen Maria Jensen Yes Abstain Abstain Dual DM Voting screen 18 DCS 6000 Digital Conference System R Voting Results esults No Subject User Manual The Results screen is displayed on all units when a voting session or attendance check is stopped It displays the latest voting or attendance check result CM Results screen stand alone Voting Results Sales strategy DM Results screen SW 6000 Attendance Check Result Present 3 AudioA Audio B New Dual DM Results screen SW Setup menu Unit Type Left Btn The Setup menu can be accessed by holding down _ the scroll down button and then pressing the left push Comm Stat Unit Status button It contains access to extended setup functionality Unit Type Left Btn Comm Stat Unit Saaerae Status and Languages Setup menu
34. plastic caps after changing the button s 11 DCS 6000 Digital Conference System The user interface can be changed to support other languages Please refer to the DCS6000 Upgrade Manual for information on creating editing and deleting languages as well as uploading them to the DC 6990P The start image can also be changed to support customised start images other text logo etc Please refer to the DCS6000 Upgrade Manual for more information The gooseneck microphone GM 652x can be locked to the unit with a 1 5 mm hex key The lock is accessible from the small hole to the left of the XLR socket Turn the hex key counter clockwise to lock the gooseneck microphone to the unit and turn the hex key clockwise to unlock the gooseneck microphone from the unit The unit can be fixed to the table top using the mounting holes on the underneath of the unit Drill a hole maximum 10mm deep using an 2 5mm drill and use a bottoming tap M3x0 5 to cut a thread Fasten the unit from below the table with a long screw that fits with the dimension of the screw hole The chip card reader is used for authentication and can only be used in combination with the SW 6000 The chip cards must be inserted with the chip facing downwards Quick Start Guide To activate the unit Press the LCD touch screen Login using code or chip card if requested Navigate on the Main screen using the control buttons Navigate to other screens u
35. r The connectors on the back on the unit located on the PCB is for professional use only 22 DCS 6000 Digital Conference System DM 6620F DM 6588F MU 6040 C D MU 6042D Flush Mounted Delegate Conference Unit e Lockable XLR socket for DIS gooseneck microphone e Speak request button e Loudspeaker e 5 voting buttons e Chip card reader The connectors on the back on the unit located on the PCB is for professional use only Flush Mounted Armrest Delegate Conference Unit XLR socket for DIS gooseneck microphone Speak request button Channel selector Headphone connector 3 voting buttons Chip card reader The connectors on the back on the unit located on the PCB is for professional use only Microphone Unit Available in Delegate D and Chairman C versions The MU 6040 Microphone Unit is designed for hidden installations e g in an armrest under a table or in a floor box for use with the FD FC series of front plates with Loudspeaker Microphone and Buttons or for use with the HD 4042 Hand Microphone The MU 6040 is provided with a HD 15S connector for connection of the FD FC front plate The MU 6040 may also be used to switch on and off a loudspeaker in PA system with separate amplification e g a 100V system via an external relay The MU 6040 operates in the same modes as the other units Dual Microphone Unit The MU 6042D Microphone Unit is designed for hidden installations
36. r Manual for typical schematics Starting up the system When the DCS 6000 Conference Units are connected to a CU 61xx Central Unit and the proper termination are made the CU can be switched ON After powering up the system the light ring in DCS 6000 Conference Units will flash until the CU identifies the unit AS soon as this happens the light ring stop to flash and the unit is operational If a unit looses the connection to the CU it will start to flash until the connection is re established Adjusting LCD contrast on units with channel selector The contrast on the channel selector LCD display has been factory preset to a viewing angle of 45 The contrast can be changed to a different viewing angle through the procedure described below 32 DCS 6000 Digital Conference System User Manual 1 Get the contrast adjustment tool which has been shipped with your DCS 6000 Central Unit see photo 1 A new adjustment tool can be ordered through your authorized DIS dealer Order DIS p n PO 45 00010 _iii Photo 1 2 Connect the CM DM 6xxxF to the DCS 6000 Central Unit and power up the system 3 Wait until text appears in the LCD display and the backlight is turned on 4 Locate the contrast adjustment hole in the back box of the unit see photo 2 Units with two channel selectors have two adjustment holes in the back box one for each of the LCD displays Photo 2
37. s DM 6680 P Conference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DC 6120 P DC 6190 P DM 6620 F CM DM 6680 F MU 6040 C D MU 6042 D DV 6501 F AM 6040 CS 6340 FV H Accessories User Manual Conference Unit flush mounted with Chip card and 5 voting buttons Conference Unit flush mounted with one built in channel selector Chip card and 5 voting buttons Microphone Unit for use with FD FC front plate with Loudspeaker Microphone and Buttons Available in Delegate D and Chairman C version Dual Microphone Unit for use with FD FC front plate with Loudspeaker Microphone and two delegate Buttons Voting Unit Ambient Microphone Unit Channel Selector flush mounted In addition to the unit a number of accessories are available like Storage Boxes GM 6523 Gooseneck Microphone 40 cm GM 6524 Gooseneck Microphone 50 cm GM 6525 Gooseneck Microphone 63 cm DH 6021 Delegate Headphone DH 6223 Stethoscope Headphone DH 6225 Ear Clip Headphone For detailed instruction in how to use the above units please refer to the User Manuals for the relevant products DCS 6000 Digital Conference System Operating instructions DCS 6000 Conference Units General description The DCS 6000 Conference Units are fully digital microcomputer controlled conference units All units include a DSP processor Digital Signal Processing The DCS 6000 Conferenc
38. sing the Menu button Start up screen When the unit is powered up an initialisation and Start up screen appears It includes the conference name if a conference has been started in the SW 6000 It also includes a delegate name if the conference is running with prepared delegate seat table login using code and list login using code on preferred seat or automatic login on preferred seat mode Press the touch screen to enter 12 User Manual John Hansen WV C Touchscreen Conferencing Start up screen with conference name and delegate name DCS 6000 Digital Conference System User Manual A I a a a If a conference requiring chip card is running the user is prompted to insert chip card before being granted access If a conference requiring login code is running the user iS prompted to enter the code on the touch screen before being granted access scroll functionality The Menu button provides access to a Menu overview with extended functionality A digital clock is available when using the SW 6000 Three different multi functional software buttons are available for the CM DM and Dual DM at the bottom of the screen The CM includes the microphone handling buttons e All Del Off All Req Off active when the indicator is on the speaker and the request list respectively e Exclusive e Next On Mic On Mic Off active when the indicator is on the first request on the r
39. started from a DC 6990P CM configuration if the system is running in stand alone mode or by using the SW 6000 The buttons can also be used for attendance check and proxy voting The proxy voting functionality is only available in combination with the SW 6000 The chip card reader is used for authentication and can only be used in combination with the SW 6000 The chip cards must be inserted with the chip facing downwards DC 6990P Portable Conference Unit or Configurable as CM DM and Dual DM 3 5 LCD color touch screen Lockable XLR microphone connector Loudspeaker Speak request button and Function button Chip card reader p 2 channel selectors oe 2 headphone connectors E NSS Exchangeable buttons A Multi language user interface The unit can be configured as a chairman delegate or dual delegate unit The unit comes per default with a delegate configuration To configure the unit type please refer to the section Setup menu The left function button can be configured with different functionality The unit comes per default with mute functionality To configure the button functionality please refer to the section Setup menu The function and speak request buttons can be changed to match the local language and selected functionality Remove the plastic caps underneath the unit and insert a thin device to eject the buttons from underneath Insert the new button by clicking it into the unit Insert the
40. tch panels HD15 connector The HD15 connector on the MU 6040 D C and MU 6042 has the following PIN layout i Loudspeaker output DIS type a2 Speak 1 LED 2029 or according to the specific 3 Request 1 LED installation 4 ON OFF 1 button input Delegate OFF button ON OFF 2 button input KE TTE Optional input Loudspeaker output 2 E ohm eC N io frem apv o raf a3 mic ground ria smc vas Request 2UED Only connected on MU 6042 Connection of GM 652x to AM MU 6040 AM MU 6040 HD 15 GM 652x XLR 3P The phase of the pairs must be correct and the wiring spec as stated in Cat5e EIA 568 B have to be followed Accessories Cat5e Connection Cables AWG24 EC 6001 0 5 stasis aces ats Connection Cable 0 5 m BC 6001 0 T ESEN Connection Cable 1 m EC 6001 02 sisetecomnreauiaas Connection Cable 2 m EC G00T OS sivsecetegeerccenainnx Connection Cable 5 m EC OO001FLO wectesecdteescieecs Connection Cable 10 m EC 6001 20 icccecececeeeeee Connection Cable 20 m EC 6001 50 Lic ceccecceceecaes Connection Cable 50 m 37 SHURE LEGENDARY PERFORMANCE www shure com United States Canada Latin America Caribbean Shure Incorporated 5800 West Touhy Avenue Niles IL 60714 4608 USA Phone 1 847 600 2000 Fax 1 847 600 1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone
41. tomatically if speaking in the microphone or by pressing the microphone ON OFF button This is indicated by a red light in the Speak lamp in the microphone unit Pressing the microphone ON OFF button again will turn the microphone off The microphone turns of automatically after finished talking after the time defined in the Release Time setting which is normally 4 seconds The microphone can also be turned off by pressing the ON OFF button A Chairman Unit is always in Auto or VOX mode Please note that Dual Units like MU 6042 and units operation in a Microphone Sharing mode cannot run in VOX mode 27 DCS 6000 Digital Conference System User Manual Individual modes only with SW 6000 The parameters can be set individual for each i i So Set nferen nit When using SW 6000 it is possible to set individual EEEE modes for the units Operation Use CU mode FIFO Manual Automatic or VOX Operation Mode Mode Automatic Automatic Speak Priority Use CU mode 5 Chairman 4 3 2 VIP 1 Delegate or No Speak Priority PEKARE E Crama Chairman 5 is the highest priority and the microphone will always be turned on regardless of operation mode 5 Chairman In the Request list a unit with higher speak priority will be placed before a unit with lower speak priority Interrupt The Interrupt setting determines the microphone s ability to Ability interrupt another speaker if the maximum num
42. tops speaking The AM 6040 Ambient Microphone Unit is designed for installation above a recessed ceiling for connection to an external microphone like DIS model HM 4042 or GM 652x series of gooseneck microphones The AM 6040 is delivered in a shielded metal mounting box like the MU 6040 e Automatic activation of the microphone if no Chairman or delegate units are turned ON and the LineIn Volume LineIn gt Loudspk is set to OFF Setting of the volume of the ambient noise audio level on the CU 61xx Note One ambient microphone can be active in the DCS6000 system at one time 24 DCS 6000 Digital Conference System Microphone functionality Microphone functionality is a feature where participant in a conference can use a microphone in a DCS 6000 Conference Unit to address an audience The sound from a conference microphone is called the Floor sound The Floor sound can then be listened to in built in loudspeakers in the DCS 6000 Conference Units in Language selectors in Interpreter Sets or the sound can be feed to an external PA system The number of allowed open microphones can be set at the CU 61xx however the sound from all the open microphones is mixed together in the Floor sound User Controls amp Indications The following list shows the function of the facilities for using the microphone in the units Please note that not all facilities are available at all units Speak button delegate
43. unction button that changes functionality depending on the configuration The chairman configuration enables all delegates off functionality in the left button while the delegate configuration enables mute and reply functionality in the left button The function button can be changed to match the current functionality by pushing the button out of the unit from below The new button is then simply clicked into the unit The gooseneck microphone GM 652x can be locked to the unit with a 1 5 mm hex key The lock is accessible from the small hole below the DIS logo on the side of the XLR socket Turn the hex key counter clockwise to lock the gooseneck microphone to the unit and turn the hex key clockwise to unlock the gooseneck microphone from the unit User Manual DCS 6000 Digital Conference System DC 6190P Portable Conference Unit e Configurable as CM and DM e Lockable XLR microphone connector e Loudspeaker e Mute all del off and speak request buttons e 2 channel selectors e 2 headphone connectors The unit can be configured either as a chairman or a delegate unit The unit comes per default with a delegate configuration To configure the unit the mute and the microphone button must be kept down while pressing the left volume up button for 10 seconds for chairman functionality or the left volume down button for delegate functionality The button light guides will flash when the unit is configured and th
44. unit Pressing the Speak button turns on the microphone or will place the microphone in the request queue see Operation modes The Operation mode determines the functions of this button Speak button chairman unit Pressing the Speak button turns on the microphone Speak LED Lights up with a red colour when the microphone is ON Request LED Lights up with a green colour when the microphone is put in the request queue see Operation modes Delegate off All del off button chairman unit Pressing the Delegate off All del off button turns off all delegate microphones Delegate off All del off LED chairman unit Lights up with a green colour when the button is pressed with the exception of the DC 6990P that lights up with a red colour in the first release Mute button Pressing the Mute button mutes the microphone while the button is activated without removing the right to speak Mute LED No LED Exclusive button chairman unit Pressing the Exclusive button mutes all delegate microphones and activates the chairman microphone while the button is activated User Manual Exclusive LED chairman unit Lights up with an orange colour when the button is activated however in the first release it will light up with a red colour Next on button chairman unit Pressing the Next on button turns on the first request on the request list Next on LED chairman unit Lights up with a red colour when th
Download Pdf Manuals