Home
Webspike 1.0 User`s Manual
Contents
1. admin Other user s Add user Yes No Delete user Yes No Change password Yes Yes Adding a new user Ll ca 192 1680101 Manage Users copyright ates 13 Webspike 1 0 User s manual Deleting an existing user y MansgrUsel A n Changing password for an user E pdt Yum Hue Remates tiep 7 Mategdhto g ue X M Op I I n J amaun JE P ae Manage Users 14 Webspike 1 0 User s manual Managing roles Only admin user can modify the privileges assigned to individual users Three kinds of privileges can be provided to each user Privilege Meaning Power on A user can switch on a power outlet Power off A user can switch off a power outlet Advanced access control A user can change power outlet properties like name After creating a new user admin must assign privileges for newly created user A newly created user by default does not have any kind of privilege Assigning privileges to an user f ere FRE ese EE L C fi 192 1680 101 Webspace version 1 Manage Roles Back copyright ntes 15 Webspike 1 0 User s manual Managing power outlets Modifying power outlet label Users with advanced access control privilege on a power outlet can change the label associated with a power outlet This provides an easy way of remembering a pow
2. Webspike 1 0 User s manual Default factory settings Network settings DHCP Enabled Yes IP Address 192 168 0 30 Net Mask 255 255 255 0 Default gateway 192 168 0 1 Login credentials User name admin Password Webspike Power outlet labels Sequence number Power outlet name 1 PSOCK1 2 PSOCK2 3 PSOCK3 4 PSOCK4 5 PSOCK5 6 PSOCK6 Power outlets states after power recycle Sequence number Power outlet state 1 OFF 2 OFF 3 OFF 4 OFF 5 OFF 6 OFF Webspike 1 0 User s manual Note Please enable pop ups from Webspike For every operation Webspike reports back the success or failure through pop ups Disabling them will prevent the users from knowing the status of an operation Webspike 1 0 User s manual Getting started Connect the power cord to 3 pin connector Plug in the power cord to a power outlet with a capacity of 6A 230V AC To start using Webspike first network should be configured Network configuration can be done in three ways 1 DHCP enabled If you are using Webspike at home or in a small office and use a router for setting up internal network then chances are high that DHCP is enabled in your network If are using Webspike at office or in a corporate network check with network administrator whether DHCP is enabled For checking whether DHCP is enabled on Windows 7 systems perfo
3. centre Change Adapter Settings 2 Right click and select properties for connection with name Local Area Connection 3 Select Internet Protocol Version 4 TCP IPv4 from the list of connections and click properties button Note down the IP Address Subnet Mask and Default gateway values 4 Plug in an Ethernet cross cable to the Ethernet port on laptop 5 Connect other end of cross cable to Ethernet port on Webspike 6 Change the IP Address Subnet mask and default gateway of the Laptop to following values IP Address 192 168 0 31 Net Mask 255 255 255 0 Default gateway 192 168 0 1 7 Pressthe reset button on Webspike 8 Open a browser and enter the IP address 192 168 0 30 in the address bar 9 Enter the login credentials admin Webspike 10 Click Configure button under Network Settings 11 Unselect Enable DHCP check box 12 Change the values for IP Address Subnet mask and default gateway of Webspike 13 Webspike will be reset and after booting new network settings will be applied 14 LCD will display the message DHCP DISABLED on first row and the second row will contain the static IP of Webspike 15 Revert back the IP Address Subnet mask and default gateway of the laptop to original values Webspike 1 0 User s manual 16 Ping the static IP of Webspike from Laptop If ping does not succeed then configure it through the steps mentioned in configuring through serial po
4. one and is lost then the only way to access Webspike is by restoring the settings to factory default values This requires physical access to the Webspike and can be done through below steps 1 Hold the function button on Webspike 2 Press and release the reset button on Webspike 3 Continue to hold the function button for five seconds The Webspike will then reset the settings to factory default values When the settings are being reset LCD will display the message Erasing 19
5. Webspike 1 0 User s Manual Nithika Electronic systems ntes LLP Webspike 1 0 User s manual No part of this document may be reproduced in any manner without the prior written consent of Nithika Electronic Systems Copyright 2013 Nithika Electronic systems LLP The information in this document is subject to change without notice The latest version of this document can always be found at ntes co in Webspike html Webspike 1 0 User s manual Introduction Webspike provides the flexibility to power on power off or reboot IT Infrastructure from a remote site Webspike lets you remotely control servers routers network switches and other electrical equipment securely through any web browser Webspike lets you manage your equipment through laptop desktop Mobile or a Tablet This manual describes the features specifications and functionality of Webspike version 1 0 Webspike 1 0 features Manage IT infrastructure and electrical equipment remotely through web Remotely switch off Equipment during idle times to save on power bills Easy to setup and use No requirement of additional software needed for using the product Provides password authenticated access to Webspike Supports up to eight users Control user access to individual power outlets Backlit 2X16 LCD displays Network Configuration Six power outlets which can be controlled through web Two power outlets which are always
6. er socket rather than by labels like PSOCK1 etc This label will now replace the reference to the power outlet names like PSOCK1 in all the webpages associated with Webspike Manage Power Outlet Select Power Outlet PSOCX Modis Power Outlet Label To aree 16 Webspike 1 0 User s manual Modifying power outlet settings By default each power outlet will be switched off after a power recycle This default state after power recycle is configurable for each individual power outlet The user can chose what should be the initial state after reboot for each power outlet AI d lt amm cfr 1921680101 Manage Power Outlet 17 Webspike 1 0 User s manual Configuring network settings Only admin can change the network settings of Webspike Clicking configure button under network settings on home page will open the Network configuration page No manual power recycle is required after changing the network settings as Webspike will be automatically power reset after changing the settings By default DHCP is enabled Static IP can be assigned so that Webspike will continue to have a well known IP and can be accessed from remote location with ease Network settings Logged m as admin Network Settings Back copyright ates 18 Webspike 1 0 User s manual How to restore factory default settings If admin password is changed from default password to a different
7. powered on RS232 Serial port interface for network configuration User defined labels for power outlets for ease of management Supports up to 1300 watts of power Supports static and DHCP IP address assignment Reset and function buttons provide the capability to reset Webspike to factory default settings Webspike 1 0 User s manual Webspike 1 0 specifications External casing made of high quality aluminium with powder coating All plastics are made of high quality fire retardant material 10Base T Ethernet Connectivity provided through high quality Pulse MAGJACK High quality fire retardant internal PVC Cabling capable of handling currents up to 10A 230V AC 6A 230V AC MCB made of highly fire retardant material provides protection against high currents Internal plastic sheets layering for extra safety PCB made of Lead free FRA material 13A International Power sockets made of highly fire retardant material High quality main power cord capable of handling currents up to 10A 230V AC Backlit 2X16 LCD display RS232 Serial port operating at 19200 bits second and 8bits No Parity 1 Stop bit setting can be used for configuring network Webspike 1 0 User s manual e Webspike Package contents Item Number of Units Webspike 1 0 Unit 10A 230V AC Power cord Ethernet Cross Cable RS232 Serial Cable PIR RI RIP Product catalogue
8. r Managenent Setup ixit Mithout Savi 11 Webspike 1 0 User s manual Webspike operation Webspike has eight power outlets of which two are always connected and the remaining six can be switched on or switched off through web Enter the IP address of the Webspike in URL field of the browser Enter the login credentials to log in to the Webspike The home page provides options to Switch off or switch on a power outlet After a power recycle all the six power outlets will be set to user defined default states Index Home Page 7 N Webso se x gt Q pi 19215810 indexrar cz Loggcd in as admin Power Uutlet Number Power Outlet Label Current Status Switch Un Switch Ufr Manage Users z infi FOEI T configure Manage Roles conngure Menage Powar r PSOCKS Network Settings conn gure copyriphi oles 12 Webspike 1 0 User s manual Managing users Webspike allows a maximum of eight users to be configured The factory default settings define a single user admin admin user has privileges to switch off or switch on any power outlet Only the admin user can create or delete users By default when a new user is created the user does not have privilege to switch on or switch off any power outlet Privileges on individual power outlets should be provided by admin for any newly created user The following matrix explains the capabilities provided to different kinds of users
9. rm the following actions 1 Goto Control Panel gt Network and Internet Network and Sharing centre gt Change Adapter Settings 2 Right click and select properties for connection with name Local Area Connection 3 Select Internet Protocol Version 4 TCP IPv4 from the list of connections and click properties button If you see the option obtain an IP address automatically selected then DHCP is enabled in your network If DHCP is enabled in your network then connect an Ethernet patch cable to the Ethernet port on Webspike Plug in the other end of patch cable to a router or switch port or any free Ethernet port Power on the Webspike and you should see a message DHCP ENABLED on first row of LCD display Second row of the LCD display contains the IP address that was assigned to Webspike by DHCP server Ping the IP address that is displayed in second row of LCD display If the ping succeeds then network is properly configured on Webspike If the ping test does not succeed then try to configure it using the methods described in DHCP disabled or configuring through serial port sections Webspike 1 0 User s manual 2 DHCP Disabled In networks where DHCP is disabled Webspike should be assigned a static IP address explicitly A Laptop or desktop can be used for performing this network configuration through following steps 1 Goto Control Panel Network and Internet gt Network and Sharing
10. rt section 3 Configuring through serial port Webspike network can also be configured through serial port by following the below steps 1 2 3 4 5 6 7 8 9 Connect the serial port of Webspike to a desktop s serial port through serial cable Run a putty or HyperTerminal serial connection on the desktop with the following settings 19200 bits second 8bits No Parity 1 Stop bit Hold the function button on Webspike Press and release Webspike reset button Release the function button after 1 second Remember if you continue to hold the function button for more than 5 seconds then all the settings will be lost and will be initialized to factory default settings Webspike network configuration menu will be displayed on the serial connection Depending upon whether DHCP is enabled or disabled the settings should be changed If DHCP is disabled then set IP Address Subnet mask Default gateway and name server After changing the settings enter O to exit from connection manager 10 Webspike will be reset and after booting new network settings will be applied 10 For powering on or powering off a server remotely BIOS settings should be changed AC power auto recovery setting should be set to ON Below screen shots explain the procedure for enabling this Depending upon the kind of system BIOS the menu names and placement may vary across different systems timized Default DET bith batu f gt Powe
Download Pdf Manuals
Related Search
Related Contents
* this パラプレーン パーツリスト No. 2 / 2 General No. 25 Handy™ General D-25 Handy™ Manuel d`instructions Obtenir conseils gratuits, confidentiels, concentré d`affaires de PI AdeptMotion VME Developer`s Guide No estéril. No esterilizar en este envase. Copyright © All rights reserved.
Failed to retrieve file