GuvenCE User Manual v2.01

image

Contents

1. 1 PIN Request 3 Security 3 2 PIN Change 4 2 VersionNo 4 4 ManufacturerInfo 4 SystemInfo 4 5 DealerInfo 5 1 InternalRescueFactoryDefaults 5 ReturnToDefaults 5 2 ExternalRescueFactoryDefaults T rk e 6 Language Dil English Figure 3 Menu Tree Version 2 01 www asronik com asrun k ASAMS R KUM PARAMETERS DESCRIPTION 1 Settings 1 1 1 2 1 3 1 4 1 5 1 6 Rescue Type This parameter is only monitor able not changeable Look for 5 ReturnToDefaults parameters to change it Torque Set This is the turning torque of the motor If this parameter sets to too high the UPS will switch off to protect it selves If this parameter sets too low the motor can not rotate Reverse Rotation Limit GuvenCE Emergency Rescue System decides the rotation of the motor by sensing the motor current See Figure 4 If the motor current Iywor 1s smaller than 1 3ReverseRotat onLimit value percent of the motor current while the motor can not tum motorNotTum GuvenCE thinks that motor is rotate and continues the rescue operation In other words ReverseRotationLimit MotorNotTurn x 100 I lt I Motor If the motor current is bigger than this value GuvenCE thinks that motor cannot turn and stop the motor and tries to turn the motor in the opposite direction Motor Current Motor I MotorNotTurn MotorNotTurn 1 3 ReverseRotationLimit Time FR Relay Active Pa
2. 2 Process Controlled by GuvenCE Emergency Rescue System USING GuvenCE EMERGENCY RESCUE SYSTEM MENU All parameters of GuvenCE Emergency Rescue System are numbered and grouped Thus is extremely easy to reach the desired parameter and view or change values When GuvenCE shows the main screen press ENTER for 3 seconds to enter the menu Press UP and or DOWN buttons for touring in the menu For entering to any parameter group press ENTER button For example to go into l group press ENTER then it shows to you 1 1 RescueType parameter You can tour parameters by using UP and or DOWN buttons similarly To change selected parameters press ENTER When you press ENTER button gt symbol appears You can change the parameter values as you want with UP and or DOWN buttons After you changing the value press ENTER to confirm or press ESC to cancel After confirming the changes gt symbol disappears then new value saves to the memory and it activates immediately Similarly cancelling the changes gt symbol disappears but old value continuous to use Look into the schematically shown Menu Tree in Figure 3 www asronik com Version 2 01 asronik ASANS R KUMANDA S STEMLER MENU TREE 1 1 RescueType 1 2 TorqueSet fact setting 100 1 3 ReverseRotationLimit fact setting 90 1 Settings 1 4 DoorType 1 5 DoorOpeningTime 1 6 Max RescueTime fact setting 30 2 1 RescueCount 2 Reports 2 2 TotalEnergizedTime 3
3. enter an incorrect password 5 times consecutively GuvenCE blocks itself The rescue Operation continues to work but only accessing the parameters are disabled When your password blocked GuvenCE gives a key number that appears on the LCD Call to Asronik tell this key and get the PUK number Then enter the PUK to activate GuvenCE Rescue Board again 3 2 PIN Change GuvenCE displays this menu only the password activated You can change your password in this menu To changing the existing password first enter the current password than enter the new password GuvenCE wants to enter the new password again for confirmation After this process PIN Changed message appears Then the new password will be activated 4 System Info 4 2 Version No This parameter shows to you the firmware version number 4 4 Manufacturer Info This parameter shows to you the contact information s of the Asronik You can reach all information s of manufacturer with entering UP and or DOWN buttons 4 5 Dealer Info This parameter shows to you the contact information s of the your local dealer You can reach all information s of your local dealer with entering UP and or DOWN buttons 5 Return To Defaults 5 1 Internal Rescue Factory Defaults This parameter returns to factory settings for the application that bir NC amp GuvenCE works together 5 2 External Rescue Factory Defaults It considered for external rescue panel applications All the functions de
4. operating mode e If GuvenCE emergency rescue system cannot automatically start operating and implement rescue process 1t was may be cause by a malfunction either n the system or In an external connection error After the electricity is ok the lift return to the normal operation NOTE If desired a copy of this page can be hung inside the lift cabin or somewhere the apartment administrator can reach Version 2 01 www asronik com asronik Operation Principles of GuvenCE Rescue System with birINCI Controller Board GuvenCE Emergency Rescue System are working with bir NC Controller Board which is placed in control panel So connection commissioning and ease of use are provided Below both bir NC and GuvenCE control processes described However bir NC and GuvenCE can control main and rescue contactors separately For this reason bir NC and GuvenCE main and rescue contactor functions are described separately After examining the connection diagram of control panel and learning which board is driving the which contactor check the time diagram again 1 The processes which controlled by bir NC Control Board described below See Figure 1 Be sure to set birINCI as Rope Lift Addition check the O Rka O Rkk and O Rescue functions are adjusted correctly For further details refer to bir NC User Guide 1 1 hes 1 3 1 4 1 5 1 6 1 7 1 8 1 9 Power failure is detecte
5. asronix ASANS R KUMANDA S STEMLER GuvenCE EMERGENCY RESCUE SYSTEM USER MANUAL Guide Version 2 01 HV 2 01 SV 2 01 NOTE This guide is prepared for the hardware version 2 01 amp software version 2 01 Different version product functionalities may be changed Please be sure to check the compatibility of your product manual ASAHSUR KUMANDA S STEMLER Manufacturer Asronik Asans r ve Elektronik Ltd ti Fevzi akmak mah 10569 Sok No 26 Karatay Konya Turkiye Tel 90 332 342 41 39 Fax 90 332 342 41 43 e mail info asronik com www asronik com Service Line Tel 90 531 686 08 81 Author ZD Date of issue 09 12 2012 Hardware Version V2 01 Software Version V2 01 or newer Copyright This manual is protected by copyright All rights of this document belong to the publisher Without publisher s permission this document can not be copied or distributed Version 2 01 www asronik com asronik Rk hj F AM a TERMINAL NUMBERS AND MEANINGS IN GuvenCE EMERGENCY RESCUE SYSTEM UPS Faz UPS Notr UPS Power Input 220VAC U V W Motor Output CMA KA KA relay normally open contact output CMK KK KK relay normally open contact output FRI FR2 FR relay normally closed contact output DI Programmable digital input PNP input 24V DO DO Rescue Control digital output PNP output 24VDC AC Programmable digital input PNP input 24VDC KP Programmable digital i
6. d T1 time The absence of one phase mean power failure O Rka function becomes active and releases the main contactor T2 time The relay that assigned as O Rka function is recommended to have normally closed contacts If the elevator stays at the floor level the door will open and algorithm goes to the step 1 12 else door close command is given and the process continues to the next step Waits up to time elapsed which adjusted at parameter 2 12 Rescue StartingDelay S1 process O Rkk function will activate and rescue contactor will energize T3 time The relay that assigned as O Rkk function is recommended to have normally open contacts birINCI checks the safety circuit It expects until the safety circuit is closed circuit T4 time When the safety circuit closed circuit process continues to the next step S2 process It activates O Rescue function It means that giving a Rescue Start command to the GuvenCE T5 moment During the process of S3 it expects I RescueControl signal from GuvenCE If bir NC senses the control signal the process continues to the next step otherwise it gives RescueFault and cancels the rescue operation If bir NC senses these control signal during the S3 process RU1 KU1 down direction contactor relay and O Rh Ray function KH high speed contactor activates T6 time GuvenCE will start rescue operation Any interruption of stop or I RescueContr
7. lektronik Ltd Sti Fevzi Cakmak Mah 10569 Sok No 26 Karatay Konya T rkiye Tel 90 332 342 41 39 Fax 90 332 342 41 43 asronix KUMAN 5 EMLER Ap ina C TEM l Th IUA at 1 1 AB UYGUNLUK BEYANI EC DECLARATION of CONFORMITY MALAT I MANUFACTURER TIP TYPE ASRONIK Asans r ve Elektronik Ltd ti G venCE MALAT I ADRES MANUFACTURER ADRESS RET M YILI YEAR OF MANUFACTURE Fevzi akmak Mah 10569 Sok Etiket zerinde See data label on product No 24 Karatay Konya Turkiye R N N ADI PRODUCT NAME SER NO SERIAL NUMBER Acil Kurtarma Unitesi Emergency Rescue Unit Etiket zerinde See data label on product UYGULANAN STANDARTLAR THE FOLLOWING STANDARTS EN 81 1 A3 EN 81 2 A3 UYGULANAN DIREKTIFLER 7HE FOLLOWING DIRECTIVES Asansor Direktifi 95 16 AT Lift Directive 95 16 EC zerinde seri numaras yer alan r n i in kullan c ya We declare eligibility of above mentioned standards teslim edilen kullanim kilavuzundaki sartlara and directives to comply with the represented uyulmas durumunda yukar da belirtilen standartlara conditions on the user manual for the serial number ve direktiflere uygunlu unu beyan ederiz on the product FIRMA SORUMLUSU RESPONSIBLE OF COMPANY Elk Elt Y k M h Zafer Dedeo lu YER TAR H PLACE DATE KONYA T RK YE 09 12 2012 YETK L MZA LEGALLY BINDING SIGNATURE m 7 _ ORR ge ay 4 y
8. nput PNP input 24VDC KG Run Rescue digital input PNP input 24VDC HP HP Speaker output 8 ohm 0 5W 1000 24VDC gnd 100 24V DC USED FUSES AND FEATURES IN GuvenCE EMERGENCY RESCUE SYSTEM GuvenCE Emergency Rescue Board has two fuses which coded by F101 and F102 F101 is for 24VDC power supply in other words it connected on the way of 100 and 1000 labeled 24VDC power input terminals and its value is 1A F102 is on the motor current way and its value is 10A When any one of these fuses was blown first check the panel wiring Remove all terminals on GuvenCE and confirm the appropriate voltages on the corresponding terminals Then GuvenCE must be controlled visually Shutdown the UPS and electric network before replaces the fuses Then wait for discharging the capacitors on the GuvenCE To make sure discharging the capacitors follow the DC bus labeled LED It must be completely off There are high voltages on the GuvenCE which are dangerous for human life Don t do anything before take precautions above mentioned Remove the Plexiglas after DC bus LED completely off Replace the fuses with absolutely correct value fuses Never wrap wire around fuses Because products will be out of warranty If the fuses blown again and again please contact with ASRONIK without any further action on GuvenCE www asronik com Version 2 01 asrun k ASAMS R KUM Dear Valued Client Thank you for purchasing
9. ns are explained But when necessary the manufacturer should be consulted Version 2 01 www asronik com asronik WARNING A This lift has GuvenCE Emergency Rescue System In case of a power failure or blackout GuvenCE Emergency Rescue System automatically activates and lowers or elevates the lift to floor level to provide for the safe exiting of the passengers Warning for technical personnel undertaking the maintenance of the lift For your own safety disconnect the GuvenCE Emergency Rescue System during the maintenance of the lift For this reason turn off the UPS MCB s Otherwise it may run out of your control in case of power failure For a longer UPS life we recommend operating the System several times during each maintenance work This is important to keep the system continuously operable www asronik com Version 2 01 asronik OPERATING INSTRUCTIONS of GuvenCE EMERGENCY RESCUE SYSTEM e GuvenCE Emergency Rescue System operates full automatic It waits on standby mode when electricity is present e When the electricity interruption occurs GuvenCE emergency rescue system automatically starts operating and shows a warning message Cabin starts to move to the nearest upper or lower floor stops at the floor level and open the doors Thus the rescue process ends e After the rescue process it waits for electricity to be ok Afterwards the lift automatically starts to operate in normal
10. ol signal or turning the lift to the inspection mode cancels rescue operation while S4 period Opening of the door or interruption of the lock contact stops the rescue operation immediately However if these contacts closed again the rescue process starts again When the elevator reaches to floor T7 time birINCI deactivates the O Rescue function and gives stop signal to the GuvenCE In addition RU1 relay KU1 down direction contactor and O Rh Ray function KH high speed contactor deactivates It applies Door Open command When electricity is ok T8 time bir NC activates the main contactor and return to normal operation www asronik com Version 2 01 asrun k ASAMS R KUM Function Power Y failure No Acti O DoorXClose function Passive Acti O DoorXOpen S function passive Active i t O Rka I Main contactor de energised 4 S1 U Active t 2 42 Rescue i O Rkk o StartingDelay Rescue Contactor energised U function Passive S2 E Close Waiting for Safety Safety Circuit closing Active i O Rescue S3 Rescue Control function Passiv U signal waiting period Active I Rescue 3 Control Passive l Active U RU1 relay Passive l Active f l O Rh Ray fu nction Passive s a Ee R Time Reaches to the floor level Figure 1 Process controlled by bir NC Controller 2 The proces
11. performs some preliminary preparation to start the rescue process If the KG input deactivated before starting the rescue process GuvenCE cancels the rescue operation and gives this message Could Not Rescue GuvenCE gives this fault if it can not turn the motor in both directions Check 1 2 TorqueSet and 1 3 ReverseRotationLimit parameters Driver Fault t indicates a fault in inverter stage In this condition rescue process cannot be implemented Please contact Asronik Fuse Blown It indicates that motor fuse which located on GuvenCE was blown In this condition rescue operation cannot be continuing Replace the motor fuse with 10A glass fuse Motor Not Connected Safety is always the first consideration for GuvenCE while implementing the rescue operation In the beginning of rescue operation a voltage applies to the motor If motor draws current than the limit value then mechanical brake releases and rescue operation starts However if the motor does not draw any current then the brake does not release and MotorNotConected error message shown and rescue operation ends Check motor connections pulling of KU1 KH contactors during rescue operation www asronik com Version 2 01 XX xX XXXA9 I9 ZH 17a dnoj5 ZL02 5060 uuel GO O O2ZAD IG ZHO 110 oN pselold uonduosag YUO9YUOJSE MAM t Ly Zve Z 8 06 Xe3 6 Ly ZVE ZEE06 IAL HS pexoeyo CZ pemeig pseog jeuluuej pue 1 l lonuo2o ONHIq 34 UO pavejd ase
12. qta 17 1 pr AD i EA aj pra t ig i gt oy wm rst I A A TF n ASRONIK ASANSOK e EHEJ sen SAN TIC LTD STI Z IK ad ALA P O 12 I A
13. s which controlled by GuvenCE Rescue described below See Figure 2 2 1 GuvenCE detects Run Rescue signal T10 time 2 2 FR relay energizes T11 time Thus traction machines mechanical brake does not release if KUT down direction contactor and KH high speed contactor energies 2 3 KA relay energizes T12 time 2 4 KK relay energizes T13 time Rescue contactor activates 2 5 GuvenCE gives Rescue Control signal through S5 period 2 6 GuvenCE drives the motor at T14 and releases the mechanical brake at T15 2 7 Ifthe traction machine does not rotate close the mechanical brake at T16 Drive the motor again for rotates it to opposite direction at T17 and releases the mechanical brake at T18 2 8 Through S6 and S7 periods GuvenCE was open the mechanical brake and was drive the motor 2 9 When the elevator reaches to the floor level bir NC switch off the KG signal T19 time then GuvenCE activates the FR relay Thereby mechanical brake closes immediately 2 10 Then the KK relay Rescue Contactor the KA relay and FR relay deenergize respectively Version 2 01 www asronik com asronix A ANS R KUMANDA S STEMLER Function Aktif Run Rescue KG Pasif FR Aktif Relay Pasif I Aktif KA Relay Pasif 7 Aktif KK ii Relay Pasif l Aktif 1 DO g output Pasif l l Aktif a Motor i i Run Pasif i O raw vt LO N F EEE F FF E FEF Time Reaches to Figure
14. scribed in this user manual are for application that bir NC amp GuvenCE works together in same panel For different applications please contact Asronik 6 Language Dil You can select the language of messages on the LCD from this parameter Turkish and English languages are standard languages n the firmware Version 2 01 www asronik com asrun k AgAHS UN KHM IMPORTANT NOTES 1 GuvenCE Rescue System voltages are dangerous to human life Do not interfere to any cables during the power on Do not touch the PCB with bare hands Do not make short circuits 2 If the control panel power switches off for a long time switch OFF the UPS MCB s 3 1f GuvenCE Rescue System disassembly required disconnect all cables and wait 5 minutes to discharge the capacitors 4 For the motor connections use at least 2 5mm NYAF cable This requirement reduced cable losses that necessary and important for system working 5 We are spending many times for debugging the mistakes from the user manual and diagrams But may be there are some bugs The users should review the manuals with these principles Please inform us immediately if you encounter a bug in the document We will debug these mistakes in the new documents FAULT CODES GuvenCE Rescue System detects the faults by shows them on the LCD It helps to users for troubleshooting the failures easily The fault codes are as following Rescue Cancel After activating the KG input GuvenCE
15. sjoyoos s u Buimeip siy ye payejsnj Jou s pueog Ieutuus8 BulleO lqe5 alqixay s 0Z YLM s ay490S Hg JOBUUOD Z elge9 ajg xey s 0Z YM uo q uo s ayx90S L0 H8 pue Hg J UUOD INJO Jamod pue OJJUOD een Buimeiq suu 1s S ONUO9 J0 eAR F weJHelp uono uuo2o ued 07u09 nos i JOu Ano AOZZ pue 19JJ ONUOO ONIA UM s10zow paseal p ds qnop JO4 een p foid AS PH HUOUp ely OA 19SUESY YIUOJSV gt UNJ gt bay p d mo p d uBiH nn v mea gt ag FF Aa elolololol g e ele folololo olololofo o io olo elololoj ZOOVNI A YOJIMS uono dsu Jeyeolg NoD Uuon5 oid JOO uoynqyusnd dojs Aousbiew jaued 19J OUOY Aejoy jewuoyl Joynoay ayerg AOQOOL WSE SJIO9 JOJOEJUOD 0 P9JOSUUOD 9 p nous SJ9JJU OY BYL sllo92 OVAOTZ UM edi E OY 9g JsNW SJOJJEJUOJ LOEHA 1 llonuoO YIT JONH G VE i e Er ik Joyyoay Weg AOOOL WSE pueog anosay qouean 5 OUODENDSEY ENC EE S BOULO ZNO ZE S w 0UeD LNG LE S 880 9 400 0 Aejay OPY 8Z G wU8dQ 400q O Aejay OpY Z weIY O Aejay 1ASH 9Z S A O Aejey sIY SZ S wDN O Aelay PIN PZ S 9n9Say O Aejay XY EZ S AA YO Aejay Ri 2zZ S AOOOLIVSE Ae y uy O Aey Yu LZ G S ONUOYASEYd P G psjsnlpe 8g pjnoys s 9jaueJed s u l G A j SG 9 5 j o YLON San Ac A he B JAN a Asronik Asansor ve E
16. ssive Time Mechanical Brake Active Passive j Time Figure 4 The principle of Reverse Rotation Limit parameter Door Type GuvenCE works with all mono phase door motors The newer version of firmware will work with three phase door motors Door Opening Time Three phase door motors opening time will be adjust at this parameter New version of firmware will include this function Max Rescue Time This parameter identifies maximum rescue time This period shall be long enough for elevator to reach the next floor Too big values are not suitable for safety reasons It shall adjust according to the longest floor to floor distances www asronik com Version 2 01 asrun k ASARSUR KHM 2 Reports 2 1 Rescue Count This number indicates the rescues counts that have been undertaken successfully since the GuvenCE Emergency Rescue System started to run Changes are not allowed 2 2 Total Energized Time Define total run time in hours for GuvenCE Emergency Rescue System Changes are not allowed 3 Security 3 1 PIN Request You can activate PIN request by assigning a password to prevent to seeing or changing the parameters by unauthorized persons If the password was already set you shall enter the correct password to turn it off If you want to activate the password query first you shall set your password successfully Otherwise password request does not activate There is no password on factory defaults NOTE If you
17. the GuvenCE Emergency Rescue System developed using advanced power electronics technology Our mission is to present our product in the best possible performance and satisfactory operation In this respect it was designed in our modern establishment and tested utilizing modern quality control methods We highly recommend reading this document before installing as it contains important information from operation to detailed troubleshooting tips and solutions WARNING N e This manual was designed to provide helpful operation and maintenance tips for personnel who are knowledgeable and educated on electric circuits of lifts e Installation company is responsible for the knowledge and ability of installing personnel e Manufacturer is not responsible or liable for any damages that result from the misuse of or the inability to use of the product e For your own safety alterations and modifications are not allowed on the product e Personnel installing the GuvenCE Emergency Rescue System are themselves responsible for any damages they may harm e Complying with the legal regulations and safety rules are mandatory to avoid any harm to install and service personnel and product e This user manual being a part of the product should be kept near the installation for ready reference WARNING N e In this manual the connections establishment of GuvenCE Rescue systems their operations the possible problems troubleshooting tips and solutio