Home

User Manual

image

Contents

1. Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside equipment with power ON unless proper precautions are observed All internal adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for removing covers or use of extender cards openGear INTRODUCTION Developed by Ross Video openGear is a standard where various manufacturers can design their equipment to fit a common frame allowing the end user to mix and match the various openGear cards available in the market place together in one frame This allows a single frame to be used instead of multiple different vendor s frames that each would otherwise be using their own proprietary standard A simple to use monitoring and control software called DashBoard is a free program downloadable from the openGear website www opengear tv that allows the user to remotely monitor and control an openGear type card fitted within an openGear frame that meets the openGear standard for DashBoard control A link is also supplied via the IRT Electronics website www irtelectronics com under the openGear navigation section IRT Elect
2. 00 IRT 6170 AMS INSTALLATION Pre installation Handling This equipment may contain or be connected to static sensitive devices and proper static free handling precautions should be observed Where individual circuit cards are stored they should be placed in antistatic bags Proper antistatic procedures should be followed when inserting or removing cards from these bags Installation in openGear frame See details in separate manual downloadable from the openGear website www opengear tv Video analogue 3G HD SD SDI ASI G 703 data and unbalanced AES Signal Connections Signal connections are made to BNC coaxial connectors No termination of inputs is provided on the module When switched to the output the input load impedance is that of the load connected to the output Where the input signal is required to be terminated and one of the outputs is not connected to anything then this unconnected output should be terminated by an appropriate BNC terminator of the required impedance usually 75 Ohm OUT A 0 0 OUT B IRT Electronics Pty Ltd www irtelectronics com Page 8 of 18 Revision 00 IRT 6170 AMS Audio Signal Connections Audio signal connections are made to 5 pin plug in screw terminating connectors No termination of inputs is provided on the module When switched to the output the input load impedance is that of the load connected to the output There are four 5 pin audio connectors IN A OUT A Left
3. 5 control operates in the video toggle mode of operation The audio RESET pin 6 pin has no effect on the audio relay control whilst in the toggle mode of operation If switch SW1 4 has been set to ON so that the audio relays operation follows that of the video relay operation the audio SET pin is non functional Switch to ground operation If the IRT 6170 AMS has been set to switch to ground operation with the DIP switch SW1 1 OFF grounding the video SET pin will select Video Input A Main to Video Output B and Video Input B Standby to Video Output A Removing this ground will automatically video reset Video Input A Main to Video Output A and Video Input B Standby to Video Output B Unless SW1 4 has been set for audio follows video operation the same is true for the Audio SET control pin Switch to open circuit operation Likewise if the IRT 6170 AMS has been set to switch to open circuit operation with the DIP switch SW1 1 ON open circuiting the video SET pin that is removing a ground will select Video Input A Main to Video Output B and Video Input B Standby to Video Output A Grounding this pin will automatically reset Video Input A Main to Video Output A and Video Input B Standby to Video Output B Unless SW1 4 has been set for audio follows video operation the same is true for the Audio SET control pin IRT Electronics Pty Ltd www irtelectronics com Page 15 of 18 Revision 00 IRT 6170 AMS DashBoard SO
4. 9 LUl SW_ boot switch Default Reset Switch User set names and switch position are stored within memory so that in the event of a loss of power this information is restored on resumption of power If the default Reset Switch is pressed whilst powering or inserting the card the IRT 6170 AMS will default to factory preset names and input position IRT Electronics Pty Ltd www irtelectronics com Page 12 of 18 Revision 00 IRT 6170 AMS Rear Assembly Layout et qe A INPUT B INPUT A OUTPUT B OUTPUT FE Standard Rear Assembly IRT Electronics Pty Ltd www irtelectronics com Page 13 of 18 Revision 00 IRT 6170 AMS OPERATION The IRT 6170 AMS can be used for a MAIN STANDBY changeover switch or a 2x1 switcher application Switcher control is done either locally via the front edge pushbutton switches remotely by external signals alarms connected via the 8 pin HE 14 type of control connector on the rear assembly or via DashBoard software control Local Control There are three front panel momentary pushbuttons marked designated in order from top to bottom as VIDEO MAIN STANDBY AUDIO MAIN STANDBY and LOCAL REMOTE The LOCAL REMOTE switch switches between front switch local control and remote control via the 8 pin HE 14 type of control connector on the rear assembly The default state is in the remote orange setting To switch to front panel local control press this button and hold for a
5. C9 OO ED ECD CB ES opentiear SS 1am IRT 6170 AMS elay Changeover Switch ELECTRONICS User Manual IRT Electronics Pty Ltd www irtelectronics com Page 1 of 18 Revision 00 IRT 6170 AMS 3G HD SD SDI ASI G 703 Video Audio Relay Changeover Switch Revision History Revision Date By Change Description Applicable to 16 12 2013 AL Original Issue Firmware gt Revision 1 0 IRT Electronics Pty Ltd www irtelectronics com Page 2 of 18 Revision 00 USER MANUAL Table of Contents IRT 6170 AMS Section Page Revision History 2 Operational Safety 4 openGear Introduction 4 General Description 5 Technical Specifications 6 Configuration 7 DIP Switch Settings 7 Installation 8 Video Signal Connections 8 Audio Signal Connections 9 Output Terminations 9 Remote Control amp Tally Connections 10 Front Edge Switch Locations 12 Rear Assembly Layout 13 Operation 14 Local Control 14 Remote Control 15 Magnetic Latch Mode 15 Switch to ground operation 15 Switch to open circuit operation 15 Toggle Mode 15 Switch to ground operation 15 Switch to open circuit operation 15 DashBoard Software Control 16 IRT 6170 AMS DashBoard Screenshots 16 Maintenance amp Storage 18 Warranty amp Service 18 This instruction book applies to units fitted with firmware Revision 1 0 IRT Electronics Pty Ltd www irtelectronics com Page 3 of 18 Revision 00 IRT 6170 AMS OPERATIONAL SAFETY WARNING
6. FTWARE CONTROL The DashBoard Control and Monitoring System is a free application designed for remote control and monitoring of the openGear platform This is a free application downloadable from the openGear website www opengear tv As such configuration of the DashBoard program will not be described here The DashBoard manual is also downloadable from the openGear website IRT 6170 AMS DashBoard Screenshots Basic Tree View Filter On the left the basic tree view shows the frame With the tree structure G Taau penal expanded a list of cards within the frame is shown In this example slot Slot 7 Tally Interface position 6 is highlighted All sections and tabs to the right of the basic tree view Slot 10 IRT 663x Drx now relate to the card in slot position 6 in this case the IRT 6170 AMS AV Slot 12 Multi Mode Switcher f i Slot 13 Multi Mode Switcher Switcher The name of the switcher in this case AV Switcher can be set under Slot 14 Multi Mode Switcher the Configuration TAB setting Slot 15 Multi Mode Switcher Slot 16 Multi Mode Switcher Slot 17 Multi Mode Switcher Slot 18 Multi Mode Switcher Slot 19 Multi Mode Switcher F Sela A V Relay Switcher Product TAB Self explanatory Note that the Product Alias field can be set under the Configuration TAB setting Slot 20 AV Relay Switcher Card state OK Connection ONLINE Outputs Rear A
7. G HD SD ASI or G 703 data signals The audio path may be used for balanced or unbalanced audio or control signals RS232 RS422 RS485 etc The magnetic latching characteristic of the high performance relays allows momentary control and also provides for no change of path during power loss The IRT 6170 AMS is ideally suited to applications where a simple choice between two inputs or outputs is required and may be easily driven by detector circuits for automatic path selection Local switching is possible using front edge push button switches Remote switching is possible using external normally open or normally closed alarms Front edge switches use a small delay to avoid accidental switching if bumped After a period of about a minute the IRT 6170 AMS automatically switches back into remote mode Remote indication of tally status is provided for integration into central alarm and monitoring systems The IRT 6170 AMS is designed to fit the openGear standard 2RU frames which allow a mixture of cards from various manufacturers to be mounted within the same frame The DashBoard control software is available as a free download Standard features One video and two audio changeover switches in one package Video path suitable for 3G HD SD SDI Analogue video ASI G 703 signals 2 8 34 45 144 155 Mb s and unbalanced AES Audio path suitable for 2 balanced or 4 unbalanced audio or data signals and balanced AES
8. IN B OUT B Left IN A OUT A Right and IN B OUT B Right Common Ground between IN and OUT is shared via the middle pin pin 3 L AUDIO R AUDIO INA INB OUTA OUT B When wiring be sure to keep phase of audio cables the same The above connector will take either a balanced input balanced output audio or data RS 232 RS 422 etc signal or two unbalanced audio signals where the ground connectors are commoned together and the two unbalanced audio signals connected to each of the phase connections Output Terminations No terminations are provided on the module so that the switcher can function in changeover mode For 2 x 1 switcher applications the following terminations are recommended be installed Video Output A Main only is used and should be terminated at connected equipment Output B Standby should be terminated in 75Q or 50Q if being used for 50Q RF signals using a BNC termination plug Audio Outputs A only are used and should be terminated at connected equipment Output B may be terminated if desired by connecting termination resistors to the connector on the rear assembly of the module The resistor values should be chosen to match the characteristic impedance of the rest of the connected audio system For example for balanced 6000 two 3000 resistors should be used In most modern audio systems a low output impedance of approximately 40Q and input impedances of greater than 10 kQ are used If this
9. LINE Connection Product OUTPUTS Video OUT A Name Video OUT B Name Audio OUT A Name Audio OUT B Name Page 17 of 18 Revision 00 IRT 6170 AMS MAINTENANCE amp STORAGE Maintenance No regular maintenance is required Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance Storage If the equipment is not to be used for an extended period it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion Where individual circuit cards are stored they should be placed in antistatic bags Proper antistatic procedures should be followed when inserting or removing cards from these bags WARRANTY amp SERVICE Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply For situations when No Fault Found for repairs a minimum charge of 1 hour s labour at IRT s current labour charge rate will apply whether the equipment is within the warranty period or not Equipment warranty is limited to faults attributable to defects in original design or manufacture Warranty on components shall be extended by IRT o
10. Married or independent operation Momentary Set Reset control No path change on power fail Local or remote control DashBoard software monitoring and control IRT Electronics Pty Ltd www irtelectronics com Page 5 of 18 Revision 00 TECHNICAL SPECIFICATIONS Video Signal path Signal types Impedance Switching characteristic Video crosstalk between channels Frequency response Audio Low speed Data Audio Crosstalk Control Mode Tally Gnd Video SET Video RESET Audio SET Audio RESET NOTE Video Tally Audio Tally Front edge switches Connectors Video Audio Control amp Tally Relay Contact rating Power Requirements Voltage Power consumption Other Temperature range Mechanical Dimensions openGear standard Supplied accessories Ordering IRT 6170 AMS NOTE Main Standby IRT 6170 AMS 3G SDI HD SDI SD SDI ASI G 703 Video unbalanced AES Non terminating designed for 75 Q use Magnetic latching 4 port changeover relay lt 75 dB to 10 MHz measured input terminated by 75 Q lt 45 dB to 270 MHz lt 40 dB to 1 5 GHz lt 25 dB to 3 0 GHz 0 1 5 dB O Hz to 3 0 GHz lt 90 dB 20 Hz 20 kHz input terminated by 600 Q Momentary ground or open circuit switch selectable Pins 1 amp 2 Pin 3 Video Standby Pin 4 Video Main Pin 5 Audio Standby Pin 6 Audio Main Separate Audio amp Video controls or Audio follows Vid
11. ay control OFF Separate Audio and Video relay controls Default ON Audio follows Video relay control OFF Front Panel Local Remote switch automatically reverts from Local to Remote mode after a period of approximately one minute Default ON Front Panel Local Remote switch permanently stays in its set position i e does not automatically revert to Remote mode Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used OFF DIP switch control Default ON DashBoard control Remote switching control is either by switch to ground operation or switch to open circuit This allows for connection to either alarm type condition of external equipment being used to drive the IRT 6170 AMS Magnetic latch relay control needs a SET and RESET operation to switch between the two relay states whilst toggle relay control only requires a SET and removal of SET to switch between the two states With Audio follows Video control only the video control is needed as the audio relays track what the video relay is doing If video relay has been set for magnetic latch operation audio relays are also set for magnetic latch operation In Toggle mode a permanent contact or break is needed for the SET control RESET pin is not used NOTE Open circuit control implies removing a ground contact IRT Electronics Pty Ltd www irtelectronics com Page 7 of 18 Revision
12. break contact B Standby lt gt B Note In toggle mode a permanent contact or break is needed for the SET control RESET pin is not used With Audio follows Video configuration the audio relays change as per the video relay controls above Note Audio SET and RESET controls pins 5 and 6 are not used when configured for Audio follows Video configuration IRT Electronics Pty Ltd www irtelectronics com Page 10 of 18 Revision 00 IRT 6170 AMS Tally Switch status Tally is made by relay contacts switching to ground on pins 7 video and 8 audio of the 8 pin HE 14 control connector A switch to ground contact represents that the Video and or Audio relays are in a STANDBY SET position STANDBY status is represented as Input A Main to Output B and Input B Standby to Output A MAIN status is represented as Input A Main to Output A and Input B Standby to Output B IRT Electronics Pty Ltd www irtelectronics com Page 11 of 18 Revision 00 IRT 6170 AMS Front Edge Switch Locations s L pa ez O a m imc ront Edge Switches and Indicators i ps In this situation both Video and E Video Switch Audio are in MAIN position Green all Video I P A gt O P A I P B gt O P B e Audio I P A gt O P A I P B gt O P B ime Audio Switch gt mT as indicated by the green switches Local Remote Switch is in the Remote Local Remote Switch position Orange UI SWV OZ1
13. embly controls the operation of the audio magnetic latch mode of operation If switch SW1 4 has been set to ON so that the audio relays operation follows that of the video relay operation then the audio SET and audio RESET pins are non functional Switch to ground operation If the IRT 6170 AMS has been set to switch to ground operation with the DIP switch SW1 1 OFF provided the RESET pins aren t already being held to ground momentarily grounding the SET pins will select Input A Main to Output B and Input B Standby to Output A Provided the SET pins aren t already being held to ground momentarily grounding the RESET pins will select Input A Main to Output A and Input B Standby to Output B Switch to open circuit operation If the IRT 6170 AMS has been set to switch to open circuit operation with the DIP switch SW1 1 ON provided the RESET pins aren t already being held open circuit momentarily open circuiting the SET pins will select Input A Main to Output B and Input B Standby to Output A Provided the SET pins aren t already being held to open circuit momentarily open circuiting the RESET pins will select Input A Main to Output A and Input B Standby to Output B Toggle Mode With SW1 2 ON the video SET pin 3 control operates in the video toggle mode of operation The video RESET pin 4 pin has no effect on the video relay control whilst in the toggle mode of operation With SW1 3 ON the audio SET pin
14. eo switch selectable Non momentary contacts required in Toggle modes Switch to Ground Standby Switch to Open Circuit Main Pin 7 Pin 8 Momentary illuminated push button Automatic remote default setting after about a minute BNC 5 pin Phoenix pluggable screw block 8 pin HE 14 IDC 30 Vdc 0 5 A 12 Vdc lt 4VA 0 50 C ambient Suitable for mounting in an openGear 2RU rack chassis 33 6 mm x 2U x 325 mm Rear connector assembly with matching connectors for control input and tally outputs IRT 6170 AMS programmed with DashBoard control IN A to OUT A IN B to OUT B green switch indication IN A to OUT B IN B to OUT A orange switch indication Due to our policy of continuing development these specifications are subject to change without notice IRT Electronics Pty Ltd www irtelectronics com Page 6 of 18 Revision 00 CONFIGURATION DIP Switch settings SW1 Remote Control SW1 1 Video Relay Control SW1 2 Audio Relay Control SW1 3 Audio follows Video SW1 4 Local to Remote SW1 5 SW1 6 SW1 7 SW1 8 SW2 1 SW2 2 SW2 3 SW2 4 SW2 5 SW2 6 SW2 7 DashBoard Control SW2 8 DIP DIP sean Wannan IRT 6170 AMS 12345 6 7 8 SW2 OFF Switch to Ground control Default ON Switch to Open Circuit control OFF Magnetic Latch Video relay control Default ON Toggle Video relay control OFF Magnetic Latch Audio relay control Default ON Toggle Audio rel
15. is the case no termination of the unused audio output is required IRT Electronics Pty Ltd www irtelectronics com Page 9 of 18 Revision 00 IRT 6170 AMS Remote Control amp Tally Connections Remote switch control is made by either a switch to ground or switch to open circuit contact depending upon the DIP switch settings as described in the Configuration section of this manual on the 8 pin HE 14 type of connector located on the rear assembly CONTROL 1 2 GND GND Video SET S p S Video RESET Audio SET gt Audio RESET Video Tally 7 Audio Tally Control With the IRT 6170 AMS set to operate in magnetic latch mode the video and audio relays will operate and cause the input output states to cross over as follows Control Input Output SET Gnd Open Circuit A Main lt B B Standby lt A RESET Gnd Open Circuit A Main oS A B Standby lt gt B Separate video and audio controls independently switch the video and audio relays unless the IRT 6170 AMS has been configured for Audio follows Video configuration Note In magnetic latch mode only a momentary contact or break is needed for the SET and RESET controls With the IRT 6170 AMS set to operate in the toggle mode the video an audio relays will operate and cause the input output states to cross over as follows Control Input Output SET Gnd Open Circuit A Main lt B make contact B Standby lt gt A SET Open Circuit Gnd A Main o A
16. nly to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment If possible confirm this by substitution Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair The equipment should be properly packed for return observing antistatic procedures The following information should accompany the unit to be returned A fault report should be included indicating the nature of the fault The operating conditions under which the fault initially occurred Any additional information which may be of assistance in fault location and remedy A contact name and telephone and fax numbers Details of payment method for items not covered by warranty Full return address For situations when No Fault Found for repairs a minimum charge of 1 hour s labour will apply whether the equipment is within the warranty period or not Contact IRT for current hourly rate e ee ee a Please note that all freight charges are the responsibility of the customer The equipment should be returned to the agent who originally supplied the equipment or where this is not possible to IRT directly Details of IRT s direct address can be found at IRT Electronics website Web address www irtelectronics com Email sale
17. pproximately a second Switch colour then changes to green indicating that the VIDEO and AUDIO MAIN STANDBY switches are now operational Unless DIP switch SW1 5 is set to ON after a period of about a minute the LOCAL REMOTE switch automatically reverts back to the remote setting The VIDEO and AUDIO MAIN STANDBY switches independently switch the video and audio relays between MAIN Input A goes to Output A Input B goes to Output B and STANDBY Input B goes to Output A Input A goes to Output B positions To activate press and hold for approximately a second Switch colour changes between green MAIN and orange STANDBY to indicate which position the changeover relays are in If however Audio relays have been set to follow the Video relay either by the SW1 4 DIP switch position or via the DashBoard setting Audio relays will follow that of the Video relay state and the AUDIO MAIN STANDBY switch will not function except to indicate the same state as the VIDEO MAIN STANDBY switch position IRT Electronics Pty Ltd www irtelectronics com Page 14 of 18 SWV OZ19 LUl Revision 00 IRT 6170 AMS Remote Control Magnetic Latch Mode With SW1 2 OFF the video SET pin 3 and video RESET pin 4 of the HE 14 type of connector on the rear assembly controls the operation of the video magnetic latch mode of operation With SW1 3 OFF the audio SET pin 5 and audio RESET pin 6 of the HE 14 type of connector on the rear ass
18. ronics openGear cards are designed to meet the openGear standard for mounting within the openGear OG3 FR frame and its earlier version DFR 8300 frame and is fully compliant with DashBoard control The openGear frame manual DashBoard control software and information regarding the frame s power supplies controller card and frame accessories are available for download at the openGear website The term openGear is a registered trade mark of Ross Video Limited DashBoard software Control is a trade mark of Ross Video Limited IRT Electronics Pty Ltd www irtelectronics com Page 4 of 18 Revision 00 IRT 6170 AMS GENERAL DESCRIPTION BLOCK DIAGRAM IRT 6170 AMS SIGNAL PATH O P AUDIO A R E AUDIO A R O P AUDIO B R I P AUDIO B R O P VIDEO A I P VIDEOA AUDIO A L I P AUDIO A L O P O P VIDEO B AUDIO B L O P VIDEO B1 P 0 AUDIO B L I P L O Video Tally Audio Tally FPGA Video Set CONTROL Video Reset Audio Set Audio Reset The IRT 6170 AMS consists of one video and two balanced audio switches arranged as a changeover set with two inputs and two outputs No terminations are provided on the board allowing the switcher to be used in a wide variety of applications and with signals of various types and impedances The video path uses enhanced performance relays to provide switching capabilities for high speed data signals up to 2 97 Gb s and may be used with analogue video 3
19. s irtelectronics com IRT Electronics Pty Ltd www irtelectronics com Page 18 of 18 Revision 00
20. ssembly Product Alias Product Supplier is Board Rev Software Rev 1 0 Control Mode IRT Electronics Pty Ltd www irtelectronics com Page 16 of 18 Revision 00 IRT 6170 AMS Config TAB Under the Configuration TAB parameters such as Product Alias name and Input Aliases names and Channel Settings can be user set Click computer mouse into the field to change and type new name Note that if DIP switch SW2 8 has been set to the OFF position these Channel Settings will only monitor the switcher settings as set by the DIP switch control settings and the switcher state via the front edge or remote switch controls melee niccms A V Relay Switcher Device RESET INPUT ALIASES Video Input A Name Video Input B Name Audio Input A Name Audio Input B Name CHANNEL SETTINGS Revert Local Pushbutton O Set Reset Audio Relay Oo 1 Minute Delay Toggle Audio Relay D Never Ka Follow Video Output Remote Control Switching Video Relay Control Audio Relay Control Output Controls oO Ground Select k Open Circuit Select O Set Reset Video Relay Toggle Video Relay Video Outputs Audio Outputs Video OUT A O INA inc Audio OUT A Qn ine Video OUT B M INA ins Audio OUT B ina ins Outputs TAB Under this TAB monitoring of the switcher state takes place The output name correspond to the relevant switched input name slot 20 A V Relay Switcher Card state OK ON