1. Ultraviolet Monitor Keep this manual along with proof of purchase handy when contacting our offices Purchased From Date Model Serial No WARRANTY We warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been sub jected to misuse negligence or accident or misapplied or modified or repaired by unauthorized persons or improperly installed The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties expressed or implied including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the cus t
2. The operating power for a D C monitor may be supplied from a car boat or truck battery A relay within the monitor can supply output voltages to power a solenoid when the monitor reads a normal condition and an alarm when the meter reads insufficient UV intensity The voltage output for the solenoid or alarm is provided by the D C power input to the monitor If it is required to have an isolated pair of contacts the jumper may be removed between terminals 3 and 4 then the relay common contact is pin 4 Terminal 5 will be normally open and 7 will be normally closed when the meter is indicating a normal condition TROUBLESHOOTING LOW INTENSITY READINGS If during the normal operation of the purifier the intensity readings fall to an inadequate LOW level take the following steps 1 Clean the quartz sleeve see the Owner s Manual supplied with the water purifier for the proper cleaning method and note whether the intensity readings improve NOTE On water purifiers not equipped with a wiper mechanism removal of the quartz sleeve is required for cleaning 2 If after cleaning the quartz sleeve there is no significant improvement in the intensity readings it may be necessary to clean the quartz rod in the sensor probe see the Owner s Manual supplied with the water purifier for the proper cleaning method A WARNING Germicidal ultraviolet rays are harmful to eyes and skin DO NOT look directly at the germicidal lamp 3 Remo
3. 4 20mA White Blue Dry Contact Normally Open NO Yellow UV NORMAL Low Voltage Audio Alarm 12v UV NORMAL White Brown Low Voltage Audio Alarm 12v UV LOW UV NORMAL Ultraviolet lamp operating ultraviolet intensity above trip set point and NORMAL indicator light lit UV LOW Ultraviolet lamp may or may not be operating ultraviolet intensity below trip set point and LOW indicator light lit Figure 1 Digital GUARDIAN Modular Remote Options Connection MODULAR JACK ADAPTOR TOP VIEW I L mri l MODULAR NETWORK CABLE TRIP INPUT FROM ANOTHER GUARDIAN NOT SUPPLIED MULTIPLE GUARDIANS IN USE MODULAR JACK ADAPTOR 4 20mA METER NOT SUPPLIED DRY CONTACTS NORMALLY CLOSED NC WHEN NORMAL OMMON NORMALLY OPEN NO WHEN NORMAL DRY CONTACT NO AUDIO ALARM 12V ON FAULT AUDIO ALARM 12V WHEN NORMAL I i AUDIO ALARM 12V ON FAULT MODULAR JACK NETWORK CABLE ADAPTOR TWISTED PAIR WITHOUT OPTIONAL SWITCH Figure 2 Monitor Back Analog GUARDIAN Figure 3 Monitor Back Digital GUARDIAN UV INDICATOR ADJUSTMENT GAIN ADJUST RJ45 MODULAR JACK TRIP SET UV METER ADJUSTMENT l OPTIONAL OPTIONAL SOLENOID AUDIO ALARM VALVE OPTIONAL OPTIONAL SOLENOID AUDIO ALARM VALVE 4 20MA OUTPUT The 4 20mA output supplies an output corresponding to the intensity m
4. ECHNICAL SPECIFICATIONS Table 2 Technical Specifications Case Dimensions 6 wide x 4 high x 3 34 deep GUARDIAN Analog Version GUARDIAN Digital Version Current 0 015A 0 025A 120v 0 0125A 220v No load Wattage 1 8 Watts 3 Watts No load 4 20mA Output NA Sourced from GUARDIAN Dry contact rating NA 50v AC or DC 100mA NA Low Voltage Audio Alarm 12v DC 50mA ACCESSORIES Table 3 Accessories 25 0844A Modular Cable 50 foot 8 way cable with modular plugs on each end 30 0122 Modular Jack 8 Pin Surface Mount With screw terminal connection to access the output features See schematic diagram figure 1 Page 5 35 0239 Cable Assembly Coax BNC Male Connectors 50 30 0012B Time Delay 220v 50 60Hz 2 Minute For Analog Guardians only USER ASSISTANCE Please read and become familiar the GUARDIAN contact our with the contents of this manual offices weekdays between 8 30 am before installing or using the and 5 00 pm Eastern time at Tel 631 273 0500 GUARDIAN Ultraviolet Monitor Fax 631 273 0771 If after reading the manual you still Atlantic Ultraviolet Corporation have questions or concerns 375 Marcus Boulevard E mail info ultraviolet com regarding the installation or use of Hauppauge New York 11788 Website www ultraviolet com For your convenience record the following information below The model and serial number can be found on a label located on the GUARDIAN
5. GUARDIAN ULTRAVIOLET MONITOR a INTENSITY GUARDIAN DIGITAL ULTRAVIOLET MONITOR INTENSITY GUARDIAN DIGITAL ULTRAVIOLET MONITOR Installation amp Operation ATLANTIC ULTRAVIOLET CORPORATION 375 Marcus Boulevard Hauppauge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at www ultraviolet com Document No 98 1138D2 Revised January 2011 2003 2011 Atlantic Ultraviolet Corporation D Ri T a TABLE OF CONTENTS SAFETY TNS TRU CUTIONS sss deiscisescicisess cseossssscusesseccosecussdsseouoessestossucssecassestecasesacodecsaeessesseveetsdessevsee sosaeseecnseesesvousseeeveuee 3 PRODUCT APPLICATION isccscccsesccsstessedceisesssaseessesuessessstenseseadessctteousoveceseduccvencaschsetencessesoussuectiooncoveseas duscsensasereetessenssce 3 INSTALLATION viccsocsssssessocscsscsssctcnsscssvetscvensvesescotessevensonseeessesonssossecunuecesusecevi oe dion aeeoa oeieo s cossusceseossevedeosebaesevousenseeccones 3 CONVENTIONAL INSTALLATION I u aun a Sa a qami aa aaa assaka s auqa aus 3 4 GUARDIAN V CoNNEcTIoNS FOR SANITRON MobDELs S5 000 AND LARGER cccccccccesceessceesseesscessecessecsssecneecnses 4 ANALOG GUARDIAN ooo ccc cessccssecessecsseccssecssecsscesssesascesuecessecasecnsecssecaecesasesasstasecessecsasecsseceseeeaseesneeens 4 DIGITAL GUARDIAN ooo cece ccceceseecsscccseecessecsecessesasc
6. e operator to increase the trip set point pushing and holding the DOWN button allows the operator to decrease the trip set point OUTPUTS OUTPUT SOCKETS Every GUARDIAN monitor both the analog and digital versions comes equipped with two 3 pin convenience sockets These sockets provide output power for an optional solenoid valve or time delay solenoid valve combination and remote audio alarm The combined load on the AUDIO ALARM and SOLENOID VALVE output sockets 120v and 220v AC versions should not exceed 3 Amps DIGITAL GUARDIAN MODULAR REMOTE OPTIONS The digital GUARDIAN Ultraviolet Monitor is capable of supplying outputs for remote monitoring of the water purifier s operation An RJ45 modular jack located on the back of the monitor is provided to access these outputs An RJ45 modular cable and RJ45 modular jack adaptor are required to interconnect between the GUARDIAN and the remote monitoring devices The RJ45 modular cable and modular jack adaptor are not supplied and can be obtained from the factory see Accessories or contact the factory with specific requirements Table 1 Digital GUARDIAN Modular Remote Options Connection Modular Jack Modular Network Application Wire Color Cable Wire Color Trip Input Master Trip Input i Dry Contact Normally Closed NC Orange UV NORMAL Output Current Low voltage Audio Alarm Black White Green Common Negative Output Current
7. esuecasecuseeseeseseseaeceaevsasstasecessecsaseeseeseseeeaseneneeegs 4 TRIPSET POINT vccssescsssecsescsscossstcossusessssoesusstevevecustevesoeccsseusseascesesssecsosvesosesevecsseeedeveccsoeessueeni cesssecenbonsesecsooonsogessuecd oseosues 4 OUTPUTS LG u EE P OSIS T A E A EE 5 OUP56UT SOeOCGKETS LT u uapa EEEE AEE EEE ELEA AE E E E 5 D crraL GUARDIAN MODULAR REMOTE OPTIONS c ccsceecsesescessecesecesseeseecessecsecesssesssceauecesecsscecsseceseeeasceeseeess 5 A OMAs OUTPUM AEE ET E ET E E EEEE OE A E ET 6 DRY CONTACTS EETA n u ET A A E EA EE AT E EIA A T AN AET 6 REMOTE LOW VOLTAGE AUDIO ALARM ccccseesesesescscscscececsesecececcecescesesesesessesesseueuscscecuscssscecssceeceseseseeceseseseneseeesauaeauees 6 DO MOA ere at ee PB E Sua u ia 6 TROUBDESHOQOQTDINGY OS E S u l m Ru RS wu Q T a IR Su SG l q aaa uw SSS 7 LOW INTENSITY READINGS cccccccsseesscesccsecececscceseccececescecesssececuscsausususcscseseseseecesecesecesesecuencecenstsescucesesseceeseesecs T 1 0S AE AE A E PAE TE CP TOE E T T TECHNICAL SPECIFICATIONS wisaisicscascescosesecedsscsvssvowasecnesseesecesusvonscoscostenscdsseduedsobebeeeessosesoasestencovesss cases sdeanseesssbepsese 7 ACCESSORIES ssc u ASA Sanu cosevanecs casessseeusedecssvensceeessevaccssasovesecscasevesecussteesese 8 WARRANTY i D u u ee u u u uu sma usss 8 ASSISTANCKHE ssssccscssisssesssssscssetesssossssessessssesscadecessactdacenceesdsssasseaessassseisossseescessa sacsessecbedscedsstsacsa
8. eter converted to a current between 4 and 20mA The output is unaffected by reasonable line resistances but the output must be displayed by a PLC computer or 4 20mA meter which can interpret the signal A 4mA output will be displayed as 0 ultraviolet intensity and 20mA will be displayed as 100 Dry CONTACTS The Dry Contact output provides a Single Pole Double Throw SPDT output corresponding to the NORMAL or LOW intensity of the germicidal lamp The contacts are rated at 50v 100mA maximum Common will connect to Normally Closed NC when the display value is above the trip set point and the green NORMAL indicator light is lit Common will connect to Normally Open NO when the display value is below the trip set point and the red LOW indicator light is lit Remote Low VoOLTAGE AUDIO ALARM Although the AUDIO ALARM output socket provides power for a remote audio alarm these alarms must be either 120v AC or 220v AC depending on the AC voltage supplying the monitor A 12v DC 50mA maximum output is provided to power a remote low voltage audio alarm An optional Single Pole Double Throw SPDT switch can be installed with the low voltage audio alarm in a way that allows the audio alarm to be silenced during an alarm condition The audio alarm will sound again when the normal condition is restored this prevents the alarm from being accidentally disabled by the switch DC MobDELs
9. ide a programmed 2 minute time delay for solenoid valve operation This feature is disabled when shipped For the instructions to enable the time delay feature contact the factory The digital GUARDIAN provides outputs for remote monitoring of the water purifier s operation The outputs 4 20mA Output Provides current for remote display of ultraviolet intensity Dry Contacts Provides contacts for remote indication of ultraviolet trip levels 12v DC Output Provides power for a low voltage audio alarm INSTALLATION CONVENTIONAL INSTALLATION Each monitor is calibrated with its accompanying sensor probe The serial number engraved on the sensor probe must match the serial number of the monitor If installing more than one monitor DO NOT interchange sensor probes Newer GUARDIAN monitors have been calibrated for use with updated sensor probes and cannot be used with earlier model probes without factory recalibration e Verify that the operating voltage and purifier model number indicated on the monitor are the same as indicated on the water purifier Older model water purifiers may require a reducing bushing to properly mount the newer sensor probes If you are unsure whether the reducing bushing is required contact the factory 1 Unplug the water purifier from electrical outlet 2 Ifthe purifier has been in service shut off water supply to the purifier via the inlet and outlet shut off valves 3 Remove the t
10. ign Do not use this monitor for other than its intended purpose as described in this manual 7 Do not operate the monitor if the power cord and or plug are damaged or if any other damage to the monitor is visible or suspected ed 8 AX CAUTION Do not operate without proper electrical ground 9 Utility power supplied to the monitor MUST match power requirements listed on the monitor label 10 AX WARNING Always disconnect power to the monitor and unplug before performing any service or maintenance 11 SAVE THESE INSTRUCTIONS PRODUCT APPLICATION The GUARDIAN Ultraviolet Monitor visually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and water within the purifier The monitor will detect reduction of ultraviolet levels due to Fouling or deposits on the quartz sleeve Poor ultraviolet transmission through the water Color turbidity and organic or other impurities in the water can reduce or interfere with the transmission of ultraviolet rays Lamp outage component or power failure Depreciation of the lamp output due to usage or other cause lamp output gradually depreciates with use GUARDIAN monitors are available with either an analog or digital intensity meter All GUARDIAN monitors provide output sockets for the operation of an optional solenoid valve or time delay sole noid valve combination and optional audio alarm The digital GUARDIAN can prov
11. installed should open and the NORMAL indicator light should come on The analog meter should read between 3 and 1 00 or the digital meter should read between 30 and 100 11 Open outlet valve If for any reason the ultraviolet intensity falls to an inadequate level the display will indicate in the trip area generally less than 3 on the analog meter or 30 on the digital the LOW indicator light will light the optional audio alarm if installed will sound and the optional solenoid valve if installed will close GUARDIAN CONNECTIONS FOR SANITRON MopeLs S5 000 AND LARGER ANALOG GUARDIAN On SANITRON models 5 000 and larger with solenoid valves installed two ultraviolet monitors can be operated in series with each pair of purifiers connected in series If solenoid valves are not installed see Conventional Installation for installation and connection instructions 1 Install sensor probe and monitor See Conventional Installation for installation instructions connect as follows 2 Plug the first monitor into an electrical outlet 3 Plug the second monitor into the SOLENOID VALVE socket of the first monitor 4 Plug the solenoid valve into the remaining SOLENOID VALVE socket Note In operation the solenoid valve will close if the ultraviolet intensity in either purifier falls below normal operating limits An audio alarm should be plugged into each monitor DIGITAL GUARDIAN O
12. n SanitrontM models 5 000 and larger with solenoid valves installed multiple monitors may be connected to operate together to power a solenoid valve when both monitors are reading NORMAL and to operate external warn ings when any monitor s readings are LOW If solenoid valves are not installed and the audio alarm outputs are not shared see Conventional Installation for installation and connection instructions To link the output signals of two or more digital guardiantM monitors consult our technical support staff TRIP SET POINT The GUARDIAN is calibrated at the factory to the ultraviolet output of the lamp and the water purifier for which the monitor will be used The sensitivity should not be changed except where necessary for wastewater applications contact the factory with specific requirements On the digital GUARDIAN two push buttons on the back of the monitor allow the user to display or adjust the trip set point The point at which the indicator lights change from red to green or vice versa and the relay contacts change over e The digital display on the front of the monitor will show the relative ultraviolet intensity 0 to 100 After pushing either button for less than a second the display will show the trip set point before returning to the normal display For wastewater applications the operator may wish to adjust the trip set point Pressing and holding the UP button allows th
13. omer or to any person for injury to person damage to or loss of property or value caused by any product which has been subjected to misuse negligence accident or modified or repaired by unauthorized persons or improperly installed Under no circumstances shall the Company be liable for any incidental consequential or special damages losses or expenses arising from the contract for this product or in connection with the use of or inability to use our product for any purpose whatsoever 8
14. ranslucent sight port plug from the center sight port fitting of the chamber INSTALLATION CONVENTIONAL INSTALLATION CONT A CAUTION The quartz rod protrudes out past the probe cap be careful not to strike rod against fitting when installing the probe 4 Insert probe into the center sight port fitting of the purifier chamber and tighten securely The use of thread sealing tape or sealing compounds and hand tools for tightening are no longer required 5 Slowly restore water supply to the water purifier pressurize keeping the outlet valve closed and check for leaks Once it is determined that there are no leaks the inlet valve can be fully opened 6 Seat the monitor on top of the sensor probe position the monitor as desired and secure by tightening the set screws in the aluminum collar 7 Any optional accessories such as audio alarms solenoid valves or cabling should be connected to the appropriate sockets or to the appropriate terminals DC version before connecting the monitor to power 8 With the monitor switch in the OFF position plug the monitor into a convenient electrical outlet or if the monitor is a DC version connect power terminals to an appropriate DC power source 9 Plug the water purifier into electrical outlet and restore power Allow purifier to warm up for approximately 10 minutes Warm up period allows germicidal lamp to reach full output 10 Switch the monitor ON The solenoid valve if
15. ustdacensessccesossdss aseecnsssesieaees 8 These instructions generally describe the installation and operation of the GUARDIAN Ultraviolet Monitor Questions that are not specifically answered by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage Carefully inspect and report all damage upon receipt of product Do not install damaged equipment Follow all instructions on all labels and tags Carefully inspect all packing materials before discarding to prevent the loss of accessories mounting hardware spare parts or instructions The information and recommendations contained in this publication are based upon data col lected by the Atlantic Ultraviolet Corporation and are believed to be correct However no ATLANTIC ULTRAVIOLET guarantee or warranty of any kind expressed or implied is made with respect to the infor mation contained herein Specifications and information are subject to change without notice CORPORATION SAFETY INSTRUCTIONS 1 Read and follow ALL safety instructions Intended for indoor use only 3 The GUARDIAN Ultraviolet Monitor should be protected from harsh environments high humidity and temperature extremes 4 The GUARDIAN Ultraviolet Monitor housing is not waterproof Serious damage can occur if internal electronics come into contact with water Do not alter the construction or des
16. ve monitor and sensor probe Place a small piece of common window glass over the sight port fitting and reapply power to the water purifier Germicidal ultraviolet rays are absorbed by window glass and will not penetrate the glass 4 Observe the condition of the lamp quartz sleeve and water The quartz sleeve should be clear and clean The germicidal lamp should operate steadily without flicker The water in the purifier should be clear 5 If the conditions of the lamp quartz sleeve and water are as stated re install sensor probe and monitor Drain the water from the purifier reapply power to the purifier and monitor and check the readings with no water in the purifier 6 If readings are NORMAL 1 0 on the analog version or 100 on the digital with no water in the purifier then there has been a change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use with the purifier See the Owner s Manual supplied with the water purifier for the recommended concentration levels 7 If you are still unable to correct the problem consult our technical support staff FusE A 5A 5mm x 20mm fuse protects the monitor from damage in the event that the audio alarm or solenoid valve outputs are short circuited The fuse can only be replaced by opening the case NOTE Opening the case may void the warranty and should only be attempted after contacting our technical support staff T