Home
Jandy CL & CV
Contents
1. Cartridge Pool Filters CL and CV Series Filters Section 10 Head Loss Curves 10 1 Jandy CL and CV Cartridge Filter Design Head Loss Curves Design Head Loss ft head CL340 CV340 CL460 CV460 CL580 CV580 30 60 90 Flow Rate gpm 120 150 Page 15 12 10 Design 8 Pressure Drop psi 6 4 2 0 LIMITED WARRANTY Thank you for purchasing Jandy pool and spa products Jandy Pool Products Inc warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase with the following exceptions e AquaLink RS units installed with Jandy Surge Protection Kits will be covered for two years e NeverLube valves are warranted for the life of pool and or spa on which they were originally installed e AquaPure Electronic Chlorine Generator Electroly
2. Table 1 Cartridge Filter Specifications CL CV 340 460 580 Filter Area ft 340 460 580 Max Flow gpm 127 150 150 Six Hour Capacity gal 45 720 54 000 54 000 Max Working Pressure psi 50 50 50 Normal Start Up Pressure psi 6 15 6 15 6 15 Dimension A 41 in 41 in 47 in 28 in I a oq o H B Port on MIOUTLET CV INLET E et nly 18 Yin CL INLET Ri RENA Port on 2 in FN CL Model ONIN JAH Only Figure 1 Dimensions Jandy CL and CV Series Cartridge Filters Page 6 Section 3 Installation Instructions 3 1 AWARNING Use equipment only in a pool or spa installation Do not connect system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 psi 1 Filter Location Select a well drained area one that does not flood when it rains Damp non ventilated areas should be avoided Provide solid mounting for the filter and pump system Install system on a concrete slab or solid concrete blocks to avoid risk of settlement Do not use sand to level the filter as the sand will wash away Filter systems can weigh up to 800 lbs Install electr
3. Pump output exceeds design flow rate of Check pump performance filter Ineffective cleaning Clean or replace filter cartridge per instructions High pressure on start up Small eyeball fitting in Pool Spa Replace with larger diameter fitting Partially closed valve on return line Check and fully open all valves on return line Too large of pump Check pump and filter selection Filter cartridges dirty Clean filter cartridges per instructions Dirt returns to pool Hole in filter cartridge Replace filter cartridge per instructions Worn o ring seal inside filter Replace o ring Cartridge Pool Filters CL and CV Series Filters Section 9 Parts List and Exploded View 9 1 Jandy CL and CV Cartridge Filter Parts Key No OO A ON N 11 12 13 14 15 16 17 18 19 20 21 22 23 List Description Handle Assembly w hardware set of 2 Handle Hardware set of 4 Gauge Air Release Assembly Pressure Gauge Tank Adapter w O ring Union Tank Top Tank Top Top Spacer Breather Tube Assembly Manifold Assembly Filter Cartridge 145 sq ft 4 required Filter Cartridge 115 sq ft 4 required Filter Cartridge 85 sq ft 4 required Tank Clamp Ring w Rod Assembly Threaded Rod and Retainer Tank O ring Outlet Tube Elbow Assembly w O rings Outlet Tube Elbow Assembly w O rings Inlet Elbow w O ring Filter Cartridge Support O ring Replacement Kit not shown Ring Retaining Bulkhead Assembly w O ring C
4. PSI This filter operates under high pressure When any part of the circulating system i e filter pump valve s clamp etc is serviced air can enter the system and become pressurized when the system is restarted Pressurized air can cause the filter lid to be blown off which can result in death serious personal injury or property damage To avoid this potential hazard follow all of the instructions in this manual A WARNING To minimize risk of severe injury or death the filter and or pump should not be subjected to the piping system pressurization test Local codes may require the pool piping system to be subjected to a pressure test These requirements are generally not intended to apply to the pool equipment such as filters or pumps Jandy pool equipment is pressure tested at the factory If however this WARNING cannot be followed and pressure testing of the piping system must include the filter and or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS e Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 100 F 38 C e Limit test to 24 hours After test visually check system to be sure it is ready for operation Notice These parameters apply to Jandy equipment only For non Jandy equipment co
5. release assembly 3 4 Filter Plumbing 1 This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 Ifthe system can be subjected to higher pressure than the maximum rating of any component install an ASME approved automatic pressure relief valve or pressure regulator in the circulation system Set the relief valve or pressure regulator to lowest working pressure of any of the components in the system 3 Place the filter on the concrete pad lined up with the inlet outlet pipes see Figures 5 and 5A 4 To reduce pressure losses 2 minimum piping is recommended for plumbing the system 5 For best efficiency use the fewest possible number of fittings This will prevent a restriction in the water flow 6 Make all plumbing connections in accordance with local plumbing and building codes Filter connections are provided with an o ring seal To avoid damage to the o rings use only a silicone base lubricant on the o rings Do not use pipe joint compound glue or solvent on inlet outlet union coupling nuts 7 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks may show up as dampness or jets of water 8 Support the inlet outlet pipes independently to prevent any undue strains on the filter valve 9 Connect the pipes usi
6. CL and CV Series Cartridge Filters Procedures in this manual must be followed exactly To obtain additional copies of this manual contact us at 707 776 8200 ext 237 For address information see back cover 2 2 Description Cartridge filters do not require sand or diatomaceous earth as the filter medium Instead the filter contains filter elements which are easily removed for cleaning or replacement Dirty water flows into the filter tank through the water line connected to the lower bulkhead inlet on the bottom half of the tank body It is directed through the filter cartridge inside of the filter The debris is collected in the filter and the clean water flows out of the filter through the upper bulkhead outlet on the bottom half of the tank body Clean water is returned through the piping system to the pool As debris collects in the filter the pressure will rise and water flow to the pool will diminish The filter will eventually become so plugged with debris that it will be necessary to remove the filter cartridges and clean them with soap and water NOTE A filter removes dirt and other suspended particles but does not sanitize the pool Pool water must be sanitized and chemically balanced for clear water The filtration system should be designed to meet local health codes At a minimum the system should turnover the total volume of water in your pool two to four times in a 24 hour period 2 3 General Requirements 1 F
7. H0291800B Installation and Operation Data Installation and Operation Manual Jandy Cartridge Pool Filters CL and CV Versa Plumb id Series Filters A WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool Spa service technician The procedures in this manual must be followed exactly Improper installation and or operation can create dangerous high pressure which can cause the filter lid to be blown off possibly causing death serious injury or property damage Improper installation and or operation will void the warranty Before installing this product read and follow all warning notices and instructions that accompany this filter Failure to follow warning notices and instructions may result in property damage serious injury or death Jandy Cartridge Pool Filters CL and CV Series Filters Page 3 TABLE OF CONTENTS Section 1 Safety Information veccccsatcsceccasissscntenss 4 Section 6 Maintenance eeeeeeeereereerereesree 10 1 1 Important Safety Warning 4 6 1 General Maintenance 0 10 1 2 General Safety Instructions 4 6 2 Pressure Gauge snk cescescesesreiadentiens 11 Section 2 General Information 0 se 5 oo Cleans the Piar E anei ii 2 1 Introduction cccccccccccccccccccceceeee 5 Section 7 WMS ZING sssini 11 Ae Pemmpnon we oe 1 Section 8 Troubleshooting eeeeeeceeeeeeeeeeee 12 2 3 General Requirem
8. V Filter Anchor Bracket Qty 4 Tank Bottom Assembly CV Filter Tank Bottom Assembly CL Filter Universal Half Unions Set of 3 and Drain Plug Cap Model No All All All All All 580 340 460 All All All 580 460 340 All All All 580 340 460 All All All All All All All All All Part No R0357100 R0359900 R0357200 R0569600 R0552000 R0357300 R0554700 R0357700 R0358700 R0357600 R0357900 R0554600 R0554500 R0357400 R0357500 R0357800 R0358100 R0555100 R0358400 R0358500 R0358000 R0405200 R0465600 R0465500 R0465400 R0466500 R0461800 Page 13 Page 14 Jandy 9 2 Jandy CL and CV Filters Exploded View CL Filter CV Filter
9. echnician to do any work on the filter pump system For technical service call 707 776 8200 ext 260 Table 2 Troubleshooting Guide _FaultSymptom Possible Problems Solutions Water is not clear Insufficient disinfectant level Check and adjust disinfectant level Incorrect pool chemistry Test and adjust water chemistry Heavy bathing and or dirt loads Adjust filter time and or water chemistry Insufficient running times Increase pump run time Filter is dirty Clean filter cartridges per instructions Hole in filter element Replace cartridge Low water flow Filter system strainer baskets dirty Check and clean strainer baskets Air leaks on suction side of pump Check all connections between pool intake and pump Restrictions or blockage in either suction or Check all lines for debris or partially closed return lines valves Filter cartridges need to be cleaned or Clean or replace filter cartridges per replaced instructions Pool water level too low Fill pool so level is above pump inlet line Pump not primed Fill pump with water at basket and replace lid Pump impeller vanes blocked Technician required Strainer baskets not being used and or Replace baskets broken Allow debris into pump Pump operating under speed low voltage Technician or electrician required Short filter cycles Presence of algae clogging filter Check disinfectant content Incorrect water chemistry Check pH total alkalinity and TDS
10. ents icc 1 0424c2 5 2 4 Specifications and Dimensions 5 Section 9 Parts List and Exploded View 13 Section 3 Installation Instructions 0006 6 9 1 Jandy CL and CV Cartridge Filter 3L Filter Locati issssrisisssississessssss 6 ra m A ela 1 3 2 Anchor Bracket Installation 6 9 2 Jandy CL and CV Filters 3 3 Filter Preparation 6 Exploded View sesrsssssvesssoeesesnessse i 3 4 Filter Plumbing 7 Section 10 Head Loss Curves 15 3 5 Clamp Installations cscccerestocesscsesiess 9 10 1 Jandy CL and CV Cartridge Filter Section 4 Start Up and Operation 9 Design Head Loss Curves 15 Section 5 Filter Disassembly and Assembly 10 Wattanty srecna 16 EQUIPMENT INFORMATION RECORD DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER Page 4 Ja dy Section 1 Safety Information 11 Important Safety Warning A WARNING Do not connect system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 PSI e Pressurized air in system can cause the filter lid to be blown off which can result in death serious personal injury or property damage Be sure all air is out of system before operating or testing the equipment A WARNING MAXIMUM OPERATING PRESSURE OF THE FILTER IS 50 PSI NEVER SUBJECT THE FILTER TO ANY OPERATING PRESSURE EXCEEDING 50
11. ge A WARNING NEVER operate the filter system at more than 50 psi of pressure Operating the filter system in excess of 50 psi can cause the filter lid to be blown off which can cause death serious personal injury or property damage A CAUTION DO NOT operate filter at water temperatures above 105 F 40 6 C Water temperatures above the manufacturer s recommendations will shorten the life span of the filter and void the warranty Open the pump hair lint pot lid and fill the pump basket with water to prime the system Replace the lid You may have to do this several times on new and seasonal start ups Completely open the air release valve on the gauge air release assembly by turning the knob on the back of the assembly fully counterclockwise do not remove the knob Be sure to open any filter isolation valves that were installed in the system Stand clear of the filter and start the pump to circulate water through the system When a steady stream of water starts to come out of the air release valve close the valve Watch the pressure gauge to be sure that the pressure does not exceed 50 psi with clean cartridges If the pressure approaches 50 psi immediately turn the pump off and clean the filter cartridges see Section 6 3 If the pressure remains high after cleaning the filter refer to the troubleshooting guide in Section 8 for possible causes and solutions Page 10 Figure 8 9 Threaded Tighteni
12. he drain plug Loosen the tank clamp ring retainer and remove the clamp ring Remove the top of the filter tank by lifting it straight up until it clears the cartridges on the inside of the tank Remove the manifold assembly by lifting it off of the outlet tube and out of the tank Pull the cartridges out of the filter tank and clean the cartridge using the instructions in Section 6 3 Using new cartridges or the clean original ones place the cartridges back into the filter tank Be sure that they are correctly seated on the cartridge support on the bottom of the tank Inspect the o ring at the top of the outlet tube for cracks and wear marks Replace if necessary Reinstall the manifold making sure that it fits squarely over the cartridges and outlet tube Inspect the tank o ring for cracks or wear marks Replace if necessary Place the o ring back onto the filter bottom Place the filter lid onto the filter tank bottom Replace the tank clamp ring See Section 3 4 for clamp installation Start the pump by following the procedures outlined in steps 2 through 7 of Section 4 1 Section 6 Maintenance 6 1 General Maintenance 1 Wash outside of filter with a mild detergent and water Rinse off with a hose Do not use solvents to clean the filter solvents will damage the plastic components of the filter Check pressure during operation at least once a week Remove any debris from the skimmer basket and hair l
13. ical controls at least five 5 feet from the filter This will allow enough room to stand away from the filter during start up Allow sufficient clearance around the filter to permit a visual inspection of the clamp ring see Fig 2 Allow sufficient space above the filter to remove the filter lid and filter element for cleaning and servicing Position the filter to safely direct water drainage Align the air release valve to safely direct purged air or water A WARNING Water discharged from an improperly positioned filter or valve can create an electrical hazard which can cause death serious injury or property damage CAUTION Maintain your pressure gauge in good working order The pressure gauge is the primary indicator of how the filter is operating 6 MINIMUM CLEARANCE 6 MINIMUM F CLEARANCE Figure 2 Filter Location Jandy 7 Ifthe filter needs to be located above the water level of the pool it can be raised 2 5 ft without affecting the pump efficiency A check valve is recommended on the suction line to the pump 8 Ifthe filter is to be installed below the water level of the pool isolation valves should be installed on both the suction and return lines to prevent back flow of pool water during any routine servicing that may be required 3 2 Anchor Bracket Installation In Florida building codes require that all appliances be securely fastened to the equipment pad in order to with
14. int pot on pump Check pump and filter for any leaks If any leaks develop turn off the pump and call a qualified pool service technician Cartridge Pool Filters CL and CV Series Filters 5 Product safety signs or labels should be periodically inspected and cleaned by the product user as necessary to maintain good legibility for safe viewing distance 6 Product safety signs or labels should be replaced by the product user when a person with normal vision including corrected vision is no longer able to read the safety signs or label message panel text at a safe viewing distance from the hazard In cases where the product has an extensive expected life or is exposed to extreme conditions the product user should contact either the product manufacturer or some other source to determine means for obtaining replacement signs or labels 7 Installation of new replacement safety signs or labels should be in accordance with the sign or label manufacturer s recommended procedure 6 2 Pressure Gauge 1 During operation of the filtration system check the pressure gauge air release assembly for air or water leaks at least once a week 2 Keep the pressure gauge in good working order If you suspect a problem with the gauge Jandy recommends you call a qualified service technician to do any work on the filter pump system A CAUTION Maintain your pressure gauge in good working order The pressure gauge is the primary indicator of h
15. ng Rod Nut w Shoulder ANA Tightening Nut w Shoulder Use a 9 16 Socket Clamp Ring Closed Position ME GAP NOT TO EXCEED 1 16 Filter Clamp Ring Assembly After the pressure gauge has stabilized turn the bezel ring so that the arrow next to the word CLEAN aligns with the needle of the gauge As the filter cleans the water and the cartridges begin to clog the pressure begins to increase When the needle of the pressure gauge aligns with the arrow next to the word DIRTY on the bezel it is time to clean the filter see Section 6 3 This indicates an increased pressure of between 10 and 12 psi above original starting pressure Section 5 Filter Disassembly and 1 Assembly A WARNING NEVER attempt to assemble disassemble or adjust the filter when there is pressurized air in the system Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off which can cause death serious personal injury or property damage Turn off the pump Switch off the circuit breaker to the pump motor 10 11 12 13 14 15 16 _Jandy IMPORTANT Completely open air release valve on top of the filter tank to release all pressure from inside the tank and system Close the filter isolation valves on the system to prevent flooding Remove the drain plug located at the bottom of the filter tank and allow the tank to drain Replace t
16. ng the unions supplied with the filter Do not use teflon tape or pipe dope on any unions Assemble the unions dry and hand tighten See Figure 6 10 If desired the CV filter drain can be plumbed using a Jandy universal union The plumbing must contain a ball valve as shown in Figure 6 A CAUTION Be sure that all provisions for wastewater disposal meet local state or national codes During any draining process one hundred gallons 100 gals or more of pool water will be discharged CL and CV Cartridge Filters are not subject to backwashing Do not discharge water where it will cause flooding or damage Page 8 _Jandy From Outlet Port Jandy Filter From Pool Pool Return Figure 5 CL Cartridge Filter Plumbing for Pool Spa Combination Jandy Pump Jandy Filter From Pool CLICV Filter Tank Bottom Cap Nut i 2 Ball ERM H y Valve 2 Pipe j R Bulkhead Alt Universal Union for Plumbing Figure 6 Jandy CL and CV Series Cartridge Filter Drain Configurations Cartridge Pool Filters CL and CV Series Filters T Nut and Threaded Rod Tightening Nut w Shoulder Figure 7 Filter Clamp Ring 3 5 Clamp Installation 1 Be certain the o ring is in position in the lower tank half Press the filter lid over the lower half sandwiching the o ring between the two halves 2 Holding the ends of the filter clamp apart position the hinged segment of the fil
17. nsult equipment manufacturer 1 2 General Safety Instructions ATTENTION INSTALLER This manual contains important information about the installation operation and safe use of this product This information should be given to the owner operator of this equipment 1 Use equipment only in a pool or spa installation 2 Before repositioning valve s and before beginning the assembly disassembly or adjustment of the clamp or any other service of the circulating system A turn the pump off and shut off any automatic controls to ensure the system is not inadvertently started during servicing B open the air release valve C wait until all pressure is relieved air will have stopped flowing from the air release valve Whenever installing the filter clamp follow Section 3 4 of this manual Clamp Installation Once service on the circulation system is complete follow Section 4 of this manual Start up and Operation Maintain circulation system properly Replace worn or damaged parts immediately Be sure that the filter is properly mounted and positioned according to these installation instructions Soy OP oP ya Do not pressure test above 35 PSI Pressure testing must be done by a trained pool professional SAVE THESE INSTRUCTIONS Cartridge Pool Filters CL and CV Series Filters Section 2 General Information 2 1 Introduction This manual contains information for the proper instal lation and operation of the Jandy
18. of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer Overheating incorrect wire runs improper electrical supply collateral damage caused by failure of O Rings DE grids or cartridge elements or damage caused by running the pump with insufficient quantities of water LIMITATION OF LIABILITY This is the only warranty given by Jandy Pool Products Inc No one is authorized to make any other warranties on behalf of Jandy Pool Products Inc THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY JANDY POOL PRODUCTS INC EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL INCIDENTAL INDIRECT OR PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY This warranty gives you specific legal rights You may also have other rights which vary by state or province WARRANTY CLAIMS For prompt warranty consideration contact your dealer and provide the following information proof of purchase model number serial number and date of installation The installer will contact the factory for instructions regarding the claim and to determine the location of the nearest designated service center If the dealer is not available you can locate a service center in your area by visiting www jandy com or by calling our technical support depar
19. or best overall performance place the system as close to the pool as possible 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and the pressure gauge are convenient and accessible for the installation and operation of the unit Protect the filter from the weather 4 If fitting a chlorinator and or any other device into the filtration plumbing circuit great care must be exercised to ensure that the appliance is installed in accordance with the Manufacturer s Instructions and any standards that may exist 5 We recommend the use of barrel unions to connect each component of the water conditioning system Page 5 to ease in future servicing Barrel unions are provided with all Jandy filters A WARNING The maximum operating pressure for this filter is 50 psi Never subject the filter to operating pressure exceeding 50 psi Operating pressures above 50 psi can cause the lid to be blown off which can result in death serious personal injury or property damage 6 When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system ensure that the maximum pressure the filtration system is subjected to does not exceed the maximum working pressure of any of the components within the system 2 4 Specifications and Dimensions See Table 1 and Figure 1
20. ow the filter is operating 6 3 Cleaning the Filter Cartridge 1 Follow the procedures outlined in steps 1 through 8 of Section 5 1 to expose the cartridge elements inside the filter 2 Remove cartridge elements and place them upright in an area suitable for washing 3 Use a garden hose and nozzle to wash each pleat of each element NOTE Algae suntan oil calcium and body oils can form coatings on filter element which may not be removed by normal hosing To remove such materials soak the element in de greaser and then a de scaler Your local pool dealer will be able to recommend suitable products Page 11 Inspect each cartridge for holes tears or excessively worn pleats Replace if necessary To reassemble the filter with the new or clean cartridges follow the procedure outlined in steps 10 through 16 of Section 5 Section 7 Winterizing 1 2 3 Turn off the pump and circuit breakers Open air release valve on top of the filter Remove the drain plug at the base of the filter to ensure that the tank is empty Store the drain plug and seal in a safe place Do not reinstall until next season at start up Drain system piping of all water Cover the system with a tarpaulin or plastic sheet to protect it from the weather Page12 Candy Section 8 Troubleshooting 1 Fora list of common problems and solutions see the Troubleshooting Guide below 2 Jandy recommends that you call a qualified service t
21. stand high wind pressures created by hurricanes Jandy provides an anchor bracket kit for this purpose Please see the Parts List in Section 9 of this manual for the correct part number Follow the Anchor Bracket Installation Kit Instructions to attach the brackets to the filter NOTE Anchor screws and washers for securing the anchor bracket to the equipment pad are not included with the filter or the anchor bracket kit Jandy recommends that a 1 4 x 2 long stainless steel Tapcon concrete screw and stainless steel flat washer are used to mount each anchor bracket to the equipment pad The Tapcon concrete screw meets Florida building code requirements After placing the filter on the equipment pad as outlined in Section 3 1 drill a 5 32 hole in the concrete at each of the four brackets on the filter The correct size concrete drill bit should be obtained when the concrete screws are purchased Install the Tapcon screws and washers through each of the four 4 anchor brackets to secure the filter to the equipment pad See Figure 3 Do not over torque the screws 3 3 Filter Preparation 1 Check carton for damage due to rough handling in shipment If carton or any filter components are damaged notify carrier immediately 2 Carefully remove the accessory package 3 A visual inspection of all parts should be made now See parts list in Section 9 4 With the carton in an upright position remove the filter tank from
22. ter clamp over both upper and lower tank flanges Bring the ends of the filter clamp together 3 Place the T nut and threaded rod assembly into the clamp Be sure the T nut is seated in the clamp in the proper orientation See Fig 7 4 Use a 9 16 socket on the tightening nut until the clamp ring halves touch each other or are within 1 16 See Fig 7 but do not overtighten as the clamp can break If unable to tighten as indicated do not operate the filter and call a service technician immediately 5 After the first week of operation check the clamp and retighten if necessary 6 Check the filter clamp at least once a month A WARNING Follow these instructions carefully Improper clamp installation can cause the filter lid to be blown off which can result in death serious personal injury or property damage Section 4 Start Up and Operation NOTE This section applies to both new pool and seasonal start up 1 Turn off the pump Switch off the circuit breaker to the pump motor Page 9 Check that the drain plug for CL filters or drain cap for CV filters is in place and tight Check that the tank clamp is correctly seated and tight See Figs 7 and 8 AWARNING NEVER start pump while standing within five 5 feet of the filter Starting the pump while there is pressurized air in the system can cause the filter lid to be blown off which can cause death serious personal injury or property dama
23. the carton 5 To mount the pressure gauge air release assembly to the top of the filter tank located in the accessory bag a Place the smaller thicker o ring onto the threads of the tank adapter see Figure 4 Slide the tank adapter through the coupling Cartridge Pool Filters CL and CV Series Filters Page 7 12x1 Stainless Steel Pan Head Screws Qty 2 Filter Base a k A i Drill Two 3 32 Holes tainless Stee Through Filter Base Screw Qty 8 Mounting Bracket Mounting tap D 1 4 x 2 1 4 S S Tapcon Ath a g HA Screw and S S Washer oal NSS Drill 5 32 Hole Anchor Tank Bottom Bracket _ 3 1 2 Thick Qty 4 Min Concrete Pad as Filter Tank Anchor Bracket Installation Anchor Bracket to Platform Installation Figure 3 Anchor Bracket Installation S Housing o O Ring Ta i Tank Adapter Tank Adapter to Housing Coupler Figure 4 Pressure Gauge Air Release Assembly nut and into the filter tank Use the flats on the tank adapter to tighten Do not overtighten b Place the larger thinner o ring onto the gauge housing Thread the housing into the coupler on the tank adapter c Orient the gauge air release assembly in the desired position Raise and thread the locknut onto the bottom of the gauge air release assembly Hand tighten the nut only Using a wrench to tighten the nut may damage the nut gauge or air
24. tic Cells carry a 5 year limited warranty on a prorated basis This warranty is limited to the first retail purchaser is not transferable and does not apply to products that have been moved from their original installation sites The liability of Jandy Pool Products Inc shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part transportation to or from the factory and any other materials required to make the repair This warranty does not cover failures or malfunctions resulting from the following Failure to properly install operate or maintain the product s in accordance with our published Installation Operation and Maintenance Manuals provided with the product s The workmanship of any installer of the product s Not maintaining a proper chemical balance in your pool and or spa pH level between 7 2 and 7 8 Total Alkalinity TA between 80 to 120 ppm Total Dissolved Solids TDS less than 2000 not including salt ppm Abuse alteration accident fire flood lightning rodents insects negligence or acts of God Scaling freezing or other conditions causing inadequate water circulation Operating the product s at water flow rates outside the published minimum and maximum specifications Use of non factory authorized parts or accessories in conjunction with the product s Chemical contamination of combustion air or improper use
25. tment at 707 776 8200 extension 260 All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty H0291800B 6000 Condor Drive Moorpark CA USA 93021 707 776 8200 FAX 707 763 7785 andy Litho in U S A 2007 Jandy Pool Products Inc 0711 For technical support call 707 776 8200 ext 260