Home

Manual - OMEGA Engineering

image

Contents

1. EEE OOE A YEAR C r3 xx OMEGA WARRANTY Shop online at omega com e mail info omega com For latest product manuals omegamanual info V LIGHT METER HHUV254SD UVA and UVC Light Meter With Data Logging SD Card OE OMEGA OMEG Anet Online Service Internet e mail omega com info omega com U S A ISO 9001 Certified Canada Servicing North America Omega Engineering Inc One Omega Drive P O Box 4047 Stamford CT 06907 0047 Toll Free 1 800 826 6342 Tel 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 Canada Toll Free 1 800 826 6342 TEL 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance U S A and Canada Mexico Latin America Benelux Czech Republic France Germany Austria United Kingdom ISO 9001 Certified Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN En Espa ol 001 203 359 7803 FAX 001 203 359 7807 info omega com mx e mail espanol omega com Servicing Europe Managed by the United Kingdom Office Toll Free 0800 099 3344 TEL 31 20 347 21 21 FAX 31 20 643 46 43 e mail sales omegaeng nl Frystatska 184 733 01 Karvin Czech Republic Toll Free 0800 1 66342 TEL 420 59 6311899 FAX 420 59 6311114 e mail info
2. e The intensity in mW cm of UVC light e Temperature in F or C as sensed by a Type K or Type J thermocouple Pressing and holding the FUNC HOLD NEXT button will bring up in order three blank five digit displays above the terms A for UVA light C for UVC light and tP for temperature Each display also automatically shows the correct unit for the parameter 1 To select the measurement mode release the FUNC HOLD NEXT button when the desired parameter appears This becomes the meter s default measurement mode until you change it Whenever the HHUV254SD is in measurement mode you can turn off the backlight which is on by default by briefly pressing but not holding the POWER ESC button To reactivate the backlight briefly press the button again Whenever the meter is in measurement mode you also can check the current date and time by briefly pressing the SET W button Doing so causes both values to appear briefly at the lower left of the display 2 To measure the intensity of UVA light seat the UVA probe with its cap on in the socket at the top of the UV254SD callout 1 7 and use the FUNC HOLD NEXT button to select UVA measurement mode If the display shows a value other than zero press the LOGGER A button which has the word Zero stenciled above it and hold it for at least three seconds until you hear a beep Then remove the cap from the probe Holding the probe by its handle point the s
3. technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2011 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do Find Everything Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE A Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies IA Wire Thermocouple RTD amp Thermistor lA Calibrators amp Ice Point References Recorders Controllers amp Process Monitors LY Infrared Pyrometers PRESSURE STRAIN AND FORCE A Transducers amp Strain Gages A Load Cells amp Pressure Gages lA Displacement Transducers A Instrumentation amp Accessories FLOW LEVEL A Rotameters Gas Mass Flowmeters amp Flow Computers WY Air Velocity Indicators A Turbine Paddlewheel Systems lA Totalizers amp Batch Controllers pH CONDUCTIVITY A pH Electrodes Testers amp Accessories A Benchtop Laboratory Meters Controllers Calibrators Simulators amp Pumps A Industrial pH amp Conductivity Equipment DATA ACQUISITION MH Data Acquisition amp Engineering Software IA Communications Based Acquisition Systems WY Plug in Cards for Apple IBM amp Compatibles A Data Logging Syste
4. 7 of the setup procedure HOLDING AND STORING MEASUREMENTS 1 To hold a measured value of light intensity or temperature press the FUNC HOLD NEXT button during the measurement Doing so will cause the word HOLD to appear at the top of the display Pressing the FUNC HOLD NEXT button again releases the hold 2 To record and recall readings press the REC ENTER button while making measurements This will make the term REC appear at the top of the display Pressing the REC ENTER button again briefly will make the term MAX appear to the right of REC and switch the display to the maximum value stored in memory during the last recording session Pressing the REC ENTER button again briefly will make the term MIN appear to the right of REC and switch the display to the minimum value stored during the last session 3 To exit recording mode press and hold the REC ENTER button for at least three seconds until the term REC disappears from the top line of the display The display will then revert to showing the current reading AUTOMATIC VS MANUAL DATALOGGING The HHUV254SD can automatically log data using any of 11 sampling times from 1 second to 1 hour To view the sampling time for which the instrument was set up press the LOGGER A button once To change the sampling time press the SET W button to enter setup mode and perform Step 9 of the setup procedure 1 To start automatic datalogging press th
5. NTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have FOR NON WARRANTY REPAIRS consult the following information available BEFORE OMEGA for current repair charges Have the contacting OMEGA following information available BEFORE 1 Purchase Order number under which contacting OMEGA the product was PURCHASED 1 Purchase Order number to cover the 2 Model and serial number of the product COST of the repair under warranty and 2 Model and serial number of theproduct and 3 Repair instructions and or specific 3 Repair instructions and or specific problems problems relative to the product relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in
6. W cm2 either directly if it has 16 15 2009 12 11 09 56 24 3 55 UVA mW cm2 17 16 2009 12 11 09 56 26 3 97 UVA mW cm2 an SD card port or 18 17 2009 12 11 09 56 28 3 94 UVA mW cm2 through an SD card 19 18 2009 12 11 09 56 30 3 94 UVA mW cm2 reader 20 19 2009 12 11 09 56 32 3 94 UVA mW cm2 21 20 2009 12 11 09 56 34 3 95 UVA mW cm2 Because the files containing the time stamped data logs have the extension xls they open in Microsoft s Excel application Figures 2 and 3 show two kinds of Excel presentations a data only screen and a graphics only screen Fig 2 Typical Excel data only screen mW cm2 Fig 3 Typical Excel graphics only screen SPECIFICATIONS Embedded microcontroller Custom one chip LSI device Display type Liquid crystal with green backlight Display size 2 05 x 1 5 in 52 x 38mm UV light types measured UVA UVC Measurement range 240nm to 390nm Measurement accuracy Full scale autoranges 4 of full scale reading 2 digits 2 mW cm and 20 mW cm Stored readings Datalogging sampling times SD card capacity Maximum minimum 1 second to 1 hour automatic mode 1 GB to 16 GB Settable parameters Date time auto power off beep sound temperature unit F or C sampling time thermocouple type K or J decimal point or comma Operating temperature Operating relative humidity 32 to 122 F 0 to 50 C 0 to 85 Power source 6 Alkaline AA ba
7. ased the HHUV254SD can make full use of the portability reliability and large storage capacities that SD memory cards offer Measurements of light intensity or temperature can be made automatically at any of 11 sampling rates between one second and one hour After time stamping and storing the measurements on an SD card plugged into the instrument a process called datalogging the user can remove the card and transfer the measurements to a laptop or desktop computer either directly or via a USB card reader The HHUV254SD has a backlit 2 1 2 in diagonal display and is powered by six AA Alkaline batteries or an optional 9 VDC AC adapter KEY FEATURES e Includes UVA and UVC probes Measures light intensity within two automatically switched full scale ranges 2 mW cm and 20 mW cm Displays maximum and minimum readings e Performs real time automatic datalogging at sampling time settable from 1 second to 1 hour Also supports manual logging and changing of card storage location Comes with 2 GB SD memory card but works with cards up to 16 GB Big 2 5 in diagonal front panel green backlit LCD is easy to read Auto power off function Powered by six AA batteries or 9V AC DC adapter OPERATING INSTRUCTIONS WHAT S IN THE CASE The HHUV254SD comes fully assembled in a carrying case along with a UVA probe a UVC probe a 2 GB SD memory card and this user s manual Figure 1 shows all of the controls and indicators
8. e REC ENTER button once The top line of the display will then show the term REC Pressing the LOGGER A button at this point will make REC flash and add the flashing term LOGGER at the top right of the display This indicates that the instrument is currently storing measured values and their time stamps in memory 2 To pause automatic datalogging press the LOGGER A button once this action makes the flashing term LOGGER disappear from the top right of the display and changes the term REC from flashing to constant Pressing the LOGGER A button again resumes automatic datalogging 3 To end automatic datalogging press the REC ENTER button and hold it for at least two seconds This action causes the REC message to disappear 4 To log data manually set the sampling time to zero using Step 9 of the setup procedure Then press the REC ENTER button once The display will show the term REC on the top line a value in the middle and below it the letter P on the left and a number from 1 to 99 on the same line to the right The number indicates the position on the SD card that will be used to store manually logged data Now press the LOGGER A button This will cause the beeper to sound and the term LOGGER to briefly appear at the upper right of the display As in automatic datalogging mode in this mode the instrument is storing measurements and their time stamps on the SD card In manual datalogging mode how
9. ensor at its end directly at the light source The display will read out the intensity of the source s UVA light component in units of mW cm 3 To measure the intensity of UVC light seat the UVC probe with its cap on in the socket at the top of the UV254SD and use the FUNC HOLD NEXT button to select UVC measurement mode If the display shows a value other than zero press the LOGGER A button which has the word Zero stenciled above it and hold it for at least three seconds until you hear a beep Then remove the cap from the probe Holding the probe by its handle point the sensor at its end directly at the light source The display will read out the intensity of the source s UVC light component in units of mW cm 4 To measure temperature first make sure neither the UVA nor the UVC probe is plugged into the instrument Then use the FUNC HOLD NEXT button to select temperature measurement mode Obtain a Type K or Type J thermocouple and seat it in the socket callout 1 8 on the top of the HHUV254SD The display will read out the sensed temperature in degrees F or C depending on the setting chosen during setup along with the type of thermocouple it is configured for To change the unit of measurement press the SET W button to enter setup mode and perform Step 8 of the setup procedure To configure the meter for use with a Type J thermocouple Type K is the default press the SET W button to enter setup mode and perform Step
10. ess the FUNC HOLD NEXT button callout 1 3 Set the current year by pressing the SET W or LOGGER A button repeatedly until the correct value appears above yy Quickly within three seconds press the REC ENTER button to store the setting The next screen that appears will have the value above mm flashing Use the SET W or LOGGER A button to navigate to the current month and press the REC ENTER button to store the setting When the next screen flashes the value above dd again use the SET W or LOGGER A button to navigate to the current day and press the REC ENTER button to store the setting Once you have set the date the display will prompt you to set the hour minute and second of the current time Again use the SET W or LOGGER A buttons to navigate to the correct values and the REC ENTER button to store the settings 4 Choose a period or a comma to represent the decimal division between integers and fractions for example American style 20 88 vs European style 20 88 Press the SET W button to make bASIC American style or Euro appear in the upper display as desired Press the REC ENTER button to store the selection 5 Enable or disable auto power off Once the format of decimal divisions has been set and stored the display will show the word yES over the term PoFF Press the SET W button until the desired automatic power off management scheme yES for enable no for disable is displayed Press t
11. ever measurements are being stored continuously with a sampling time of zero and their locations on the card can be changed 8 5 To change the storage location of manually logged data press the SET W button once this causes the P to disappear from the left side of the display and the value on its line to begin flashing Once the flashing begins you can use the SET W and LOGGER A buttons to change the flashing value to any number between 1 and 99 Once you have chosen the storage location press the REC ENTER button to save the setting This causes the value to stop flashing and the P to return 6 To end manual datalogging press the REC ENTER button and hold it for at least three seconds This action causes the REC message to disappear from the top line of the display E A B c D E E 1 Place Date Time e Ios TRANSFERRING 2 1 2009 12 11 09 55 56 237 UVA mW cm2 DATA FROM THE 3 os 4 56 m SD CARD TO A 5 4 2009 12 11 09 56 02 3 29 UVA mW cm2 COMPUTER E 5 2009 12 11 09 56 04 3 74 UVA mW cm2 NAN Nn 7 6 2009 12 11 09 56 06 3 89 UVA mW em2 s 7 2009 12 11 09 56 08 3 14 UVA mW cm2 manual datalogging of So 10 56 m measurements remove 1 10 2009 12 11 09 56 14 1 011 UVA mW cm2 the SD card from the 12 11 2009 12 11 09 56 16 0 981 UVA mW cm2 HHUV254SD and plug it 13 12 2009 12 11 09 56 18 0 673 UVA mW cm2 14 13 2009 12 11 09 56 20 0 892 UVA mW cm2 into your computer 15 14 2009 12 11 09 56 22 2 16 UVA m
12. ging 8 9 Transferring Data from the SD Card to a Computer Lssueesse 9 Specifications 9 00992 9 I0 DIA es 10 Maintenance amp Troubleshooting Tips 10 11 Replacement Parts amp Optional Accessories 11 Warranty Information 11 Return for Repair Policy 11 INTRODUCTION Thank you for purchasing General Tools amp Instruments HHUV254SD UVA and UVC Light Meter with Datalogging SD Card Please read this user s manual carefully and thoroughly before using the instrument Many industrial and commercial applications require or can benefit from measurement of the intensity of UVA and or UVC light Among them are welding to minimize exposure to blue light radiation UV sterilization of food photochemical matching erasure of electrically programmable read only memory EPROM chips production of graphic arts products exposure of photoresists and curing of inks adhesives and coatings The HHUV254SD has the performance and features needed to satisfy the most demanding aspects of these applications For example it combines the capabilities of UVA black light in the long wave 365 nm band and UVC short waves in the 254 nm band measurement in one instrument The meter also can measure surface temperature if mated with a Type K or Type J thermocouple A UVA probe and a UVC probe are supplied with the instrument Because it is microprocessor b
13. he REC ENTER button to store the selection If enabled the power off function shuts off the HHUV254SD after a period of inactivity of ten minutes 6 Enable or disable the beeper Once the desired power management function has been set and stored the display will show the word yES over the word bEEP Press the SET button until the desired setting yES or no is displayed and then press the REC ENTER button to store the selection 7 Select the thermocouple type Once the beeper has been enabled or disabled the display will show the word Set over the word type Press the SET W button until your optional thermocouple s type K or J appears on the right side of the display Then press the REC ENTER button to store the selection 8 Select the temperature unit Once the thermocouple type has been set and stored the lower part of the display will show the term t CF Press the SET W or LOGGER A button until the unit you prefer F for Fahrenheit C for Celsius is displayed Then press the REC ENTER button to store the selection as the default 9 Set the datalogging sampling time Once the thermocouple type has been selected and stored the display will show a value above the letters SP t Press the SET W or LOGGER A button to decrease or increase the value until the desired sampling time appears above SP t The options are 0 1 2 5 10 30 60 120 300 600 1800 and 3600 second
14. ms Recorders Printers amp Plotters HEATERS A Heating Cable WY Cartridge amp Strip Heaters IA Immersion amp Band Heaters LY Flexible Heaters l4 Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering amp Control Instrumentation A Refractometers IA Pumps amp Tubing A Air Soil amp Water Monitors 4 Industrial Water amp Wastewater Treatment A pH Conductivity amp Dissolved Oxygen Instruments M5080 1211
15. oduct for an extended period of time Do not drop or disassemble the instrument or immerse it in water WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s WARRANTY adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer s
16. omegashop cz Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de OMEGA Engineering Ltd One Omega Drive River Bend Technology Centre Northbank Irlam Manchester M44 5BD United Kingdom Toll Free 0800 488 488 TEL 44 0 161 777 6611 FAX 44 0 161 777 6622 e mail sales omega co uk It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications TABLE OF CONTENTS INTFOCUENON icio oe ee ee oe ee ees 3 Key Fealtuies 5 o xr Rr mre ee 3 Operating Instructions Lese 4 9 What s in the case eese 4 SEM saa Aka aa suada 222422202220 2595 5 6 Normal Operation 7 Holding and Storing Measurements 8 Automatic vs Manual Datalog
17. on the front back top bottom and right side of the HHUV254SD It also shows the main components of the supplied UVA and UVC probes Familiarize yourself with their positions and functions before moving on to the setup procedure TOP 46 i e 1 7 FRONT 12 15 BOTTOM 3 1 23 SZ LA N HH 122 fi Fig 1 The controls and indicators and other physical features of the HHUV254SD and its two supplied probes 1 1 Liquid crystal display 1 2 POWER ESC button 1 3 FUNC HOLD NEXT button 1 4 REC ENTER button 1 5 SET W button 1 6 LOGGER A button 1 7 Socket for UVA and UVC probes 1 8 Socket for Type K or Type J thermocouple 1 9 SD card socket 1 10 RS232 output jack 1 11 RESET button 4 1 12 Socket for 9VDC AC adapter 1 13 Battery compartment cover 1 14 Battery compartment cover screws 1 15 Kickstand 1 16 Tripod attachment nut 1 17 UVC probe plug 1 18 UVC sensor housing 1 19 UVC sensor 1 20 UVA probe handle 1 21 UVA sensor 1 22 UVA probe plug 1 23 UVA sensor cap SETUP 1 Choose the power source Before using the HHUV254SD be sure it is powered by fresh batteries or an optional 9VDC AC adapter plugged into the bottom jack on its right side callout 1 12 To remove the battery compartment cover remove the two screws holding it in place callout 1 14 Then install six AA batteries in the correct orientation using the polarity marks on the inside of the com
18. partment as a guide Replace the cover by replacing the two screws 2 Install an SD card To prepare for setup also install the supplied 2 GB SD memory card or another card with a capacity from 1 GB to 16 GB in the socket on the bottom of the HHUV254SD callout 1 9 When installing the card make sure its gold contacts are facing front and push the card into the socket until you hear a click To remove the card push it in until you hear a click and the card pops out Now power on the instrument by pressing the POWER ESC button callout 1 2 to generate a short beep To power off the HHUV254SD press the POWER ESC button and hold it until the instrument responds with a long beep When the meter powers on a series of transient startup screens will briefly appear Once the display has stabilized perform the following eight setup steps in the order presented 3 Set the date and time Press the SET W button callout 1 5 and hold it for at least five seconds until SEt dAtE appears on the display Quickly within three seconds press the REC ENTER button The word dAtE will appear in the center of the display along with the flashing value 00 00 00 at the lower left above yy mm dd If you press buttons too slowly in setup mode the screen will revert to the normal display To return to the setup sequence press and hold the SET W button again To move ahead to the next field in the sequence or to the next parameter pr
19. s 0 seconds to 1 hour 10 Format the SD card Once the sampling time has been set and stored the term Sd F will appear in the lower half of the display Press the REC ENTER button Pressing the REC ENTER button causes the word no or yES to appear over the term Sd F Press the W button to make a selection Choose yES whenever a new SD card is being used or when a used card is being repurposed from use with another SD card instrument or a camera for example and all data on it is to be erased Choose no to preserve any data on a card previously used with this instrument If you choose yES after you press the REC ENTER button the instrument will prompt you to confirm that decision by displaying the term Ent below yES and sounding three beeps To confirm that you want to begin the erasure formatting procedure press the REC ENTER button Ent will then flash several times and the instrument will sound another three beeps to confirm that the SD card has been erased and formatted Once the SD card has been formatted or not the display will either return to the first of the eight steps in the setup sequence setting the current date and time or show the term ESC If ESC appears press the POWER ESC button to exit the setup procedure and enter normal operating mode NORMAL OPERATION The UV254SD can measure and store three different kinds of values e The intensity in mW cm of UVA light
20. tteries or optional 9 VDC AC adapter Power consumption Dimensions of meter Weight of meter 6 5 mADC normal operation with backlight off and SD card not saving data 30 mADC with backlight on 6 97 x 2 68 x 1 77 in 177 x 68 x 45mm 12 38 oz 3519 Dimensions of UVA probe head Dimensions of UVA probe handle 1 77 in diagonal x 1 26 in L 45 x 32mm 0 94 in diagonal x 4 92 in L 24 x 125mm Weight of UVA probe 3 53 oz 1009 Dimensions of UVC probe 1 50 diagonal x 0 98 in L 38 x 25mm Weight of UVC probe 3 63 oz 103g MAINTENANCE amp TROUBLESHOOTING TIPS Keep the UV light probes clean and their sensors under their protective covers when not in use When the icon LX appears in the left corner of the display it s time to replace the six AA batteries that power the instrument although measurements will remain valid for several hours after the low battery indicator first appears Replacing the batteries requires removing the two screws that hold the battery compartment cover in place as explained in Step 1of the setup procedure on page 5 After inserting fresh batteries in the correct orientation tighten the screws to secure the cover 10 If the meter freezes like a computer and buttons become unresponsive try resetting the instrument by pushing the RESET button on its right side callout 1 11 of Fig 1 with the end of a paper clip Remove the batteries when storing this pr
21. uggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRA