1. C Infineon Errata Sheet V 1 1 2003 12 Device C868 1RR RG Marking Step Step ES CA CA Package P TSSOP 38 P DSO 28 This Errata Sheet describes the deviations from the current user documentation The module oriented classification and numbering system uses an ascending sequence over several derivatives including already solved deviations So gaps inside this enumeration can occur Current Documentation e C868 User s Manual V1 0 January 2003 e C868 Data Sheet V1 0 May 2003 e Instruction Set Manual 07 2000 Note Devices marked with EES or ES are engineering samples which may not be completely tested in all functional and electrical characteristics therefore they should be used for evaluation only The specific test conditions for EES and ES are documented in a separate Status Sheet Contents SEGUON heir wea eae ke ae E oe eee ee ie eee ere deere Page History List Change Summary 0 000 eee eee 2 Functional Deviations 00 000 eee 3 Deviations from Electrical and Timing Specification 5 Application Hints oc coc scsi ce edewe ees eceeees Sadeeeews eae eee ee ee ee ees 6 Errata Sheet C868 1RR RG Step ES CA CA 1 6 K Yang V 1 1 2003 12 Infineon Errata Sheet History List Change Summary 1 History List Change Summary since last CPU Step ES BA previous Errata Sheet V1 0 Table 1 Functional Deviations Functional Short D
2. ation hint is renamed as PD H1 Workaround Use a ceramic resonator instead of a crystal with a fast oscillator startup phase Application Support Group Singapore Errata Sheet C868 1RR RG Step ES CA CA 6 6 K Yang V 1 1 2003 12
3. escription Fixed Change Deviation in Step CCU 2 T12 Shadow Transfer for Phase Delay Function ADC 1 Selection of ADC conversion by hardware by just writing a 1 to CCU_ADEX bit does not work SYS 2 Brownout BO threshold level is too low New Table 2 AC DC Deviations AC DC Short Description Fixed Change Deviation in Step None Table 3 Application Hints Application Short Description Fixed Change Hint in Step PD H1 After wakeup from power down PLL might unlock if Updated oscillator startup is long Errata Sheet C868 1RR RG Step ES CA CA 2 6 K Yang V 1 1 2003 12 Infineon Errata Sheet Functional Deviations 2 Functional Deviations CCU 2 T12 Shadow Transfer for Phase Delay Function In Hall mode T12MSELx 1001 T12 never reaches its period value in normal operation because a detected hall event on CCPOSx captures the actual T12 count value to CC60R speed reference and resets T12 But this period event is needed to trigger the shadow transfer of T12 register i e an update of the timer registers e g CC61R as variable phase delay is not possible The shadow transfer should be triggered together with the reset event of T12 Workaround The shadow registers of T12 are transparent if the timer is stopped and if the shadow transfer is enabled STE12 1 Therefore it is possible to write the new value to the shadow registers by enabling the shadow trans
4. evel is too low for a safe operation It cannot be guaranteed that the device is working correctly down to such a low voltage Thus the use of this feature is not encouraged It must be kept disabled at all time by ensuring that bit SFR PMCONO 4 EBO bit is written with 0 only The brownout detection section will be removed from future documentations Workaround None Errata Sheet C868 1RR RG Step ES CA CA 4 6 K Yang V 1 1 2003 12 Infineon Errata Sheet Deviations from Electrical and Timing Specification 3 Deviations from Electrical and Timing Specification No deviations from the Electrical and Timing Specification are known for this step Errata Sheet C868 1RR RG Step ES CA CA 5 6 K Yang V 1 1 2003 12 Infineon Cofion Errata Sheet Application Hints 4 Application Hints PD H1 After wakeup from power down PLL might unlock if oscillator startup is long In the User s Manual it is stated that there will a period of start up phase before PLL starts locking Conversely PLL starts to lock even during the start up phase And once the lock detection circuit has output an OK signal the program will start running However due to instability of start up phase and inadequate lock detection period of 4096 clocks 153 us 10 67 MHz PLL might unlock and generate a PLL reset This will cause a rebooting if BSL mode is enabled and therefore the wakeup process is corrupted Note This applic
5. fer stopping T12 and starting T12 again This is equivalent to a hardware triggered shadow transfer event Inevitably some clocks for the capture compare events are lost in between the stop start operation It has to be noted that bit STE12 is cleared by hardware after a shadow transfer event ADC 1 Selection of A D conversion by hardware by just writing a 1 to CCU_ADEX bit does not work Selection of A D conversion by hardware by just writing a 1 to CCU_ADEX does not work The analog input channel selection can only be latched when ADST bit is set So during hardware trigger mode ADST needs to be 1 to select the input channel and CCU_ADEX needs to be 1 to select the conversion to be started by T13 period match event Please note that when ADST and CCU_ADEX are both set at the same time in one instruction conversion is started by hardware In case ADST is set before CCU_ADEX conversion is started immediately by software Workaround In software set ADST CCU_ADEX at the same time together with the desired input channel selection to enable conversion triggered by T13PM For example MOV ADCONO 8CH enable hardware triggered conversion for channel 4 Errata Sheet C868 1RR RG Step ES CA CA 3 6 K Yang V 1 1 2003 12 Infineon Errata Sheet Functional Deviations SYS 2 Brownout BO threshold level is too low The brownout BO threshold l
Download Pdf Manuals
Related Search
Related Contents
Avaya 3100 IP Phone User Manual Exterior 600 Copyright © All rights reserved.
Failed to retrieve file