1. Seekirk Inc A1600 User Manual pg 15 Seekirk Inc Seekirk Inc A1600 User Manual pg 16
2. xc l lt x gt Sl z oc m xe j hz o njon gt SjSSSS IIIS 5 q o E 2 2 lt ped 2 oO Q c 6 O Terminal card configuration for either single or dual points per window with alarm card or alarm card with pushbutton panel Terminal Connection Definitions Provides source voltage to external field contact ic Input from an external field contact A change in the status of the external field contact will initate an alarm sequence arm 3 in the point sequencer card for that alarm point AUX RLY POINT A B C D Auxiliary relay associated with their respective field contact input F C A B C D The auxiliary relay will will change contact status upon a change in the status of their respective field contact input Terminal card configuration for triple or quad points per window Alarm card is not available in this configuration Figure 1 Rear Panel View Wiring Terminal Definition Seekirk Inc A1600 User Manual pg 5 Seekirk Inc Figure 2 provides a wiring hookup example It should be noted the field input F C A D all auxiliary relays contacts and main alarm relay contacts are configurable for either normally open N O or normally closed N C via jumper selectors on the point cards and the alarm relay card Field Contacts Typical N O or N
3. Field Contact Wiring to the Annunciator Wiring of the field contact input allows the triggering of an alarm event at the unit a The terminal on the terminal board located on the rear panel of the annunciator labeled FC COM Field Contact COMmon voltage is the source or excitation voltage which can be wired to one side of the field contact switch of the device to be monitored The other side of the field contact switch is wired to one of terminals labeled F C A F C B F C C or F C D Figure 1 provides the definition of the labels associated to the wire connection terminals WARNING DO NOT connect any of the FC COM terminals to the 0V terminal 6 Connect Auxiliary and Main Alarm Relay Wiring to the Annunciator Refer to figure 1 for the auxiliary and main alarm relay wiring terminal locations The wiring terminals for the auxiliary relays are located on the rear panel of the annunciator and are labeled as POINT A B C D AUX RLY The wiring terminal for the main alarm relay contacts are located at the lower left corner of the annunciator as viewed from the rear The terminal is labeled ALARM CONTACTS Seekirk Inc A1600 User Manual pg 4 Seekirk Inc 4 o N 4 oO u 0 0 m lt r xe njon rm KC O0 Z 0 SssSSSSS DERDI JSS Sbbbbii on Sa oO a SS SS 00L m
4. Selectors Seekirk Inc A1600 User Manual pg 9 Seekirk Inc A1600 Standard Alarm Sequencing The following table provides the sequence of events for standard alarm sequence types STANDARD POINT LOGIC CARD SEQUENCES Gere CO Oa wn l IR O ean E RE 1 GEORG r OF EVENTS li OCCURS WHEN FIELD CONT RETURN TO NORMAL BEFORE XUZA TE _ Im IM POINT CARD USHBUTTON FIELO SEQUENCE CONTACTS STATUS OPERATION CONTACTS STATUS j H lt ot Ha pep gg VISI AUD fi m v 225 FLASH ON FLASH ON FLASH ON ON FLASH ON ON z BRE dwene eee F E 2 a JE 1 SUB VISUAL AUDIBLE 15T VISUAL 5 SLOW FLASH SLOW FLASH SUB VISUAL OFF F3A 3 AUDIBLE OFF 1ST VISUAL A TON FLASH S agt hendi SUB VISUAL AUDIBLE Orr P gt NOTE 1 STEP 5 OR 6 IN EITHER SEQUENCE OF EVENTS OR II ARE NOT APPLICABLE NA WHERE SPECIFIED 2 2 g 39 g paapaa o I2 2 33 P gt NOTE 2 AT ANY TIME DURING THE SEQUENCE OF EVENTS OPERATION OF THE 1ST OUT RESET WILL CAUSE THE 1ST VISUAL TO REVERT TO THE SUBSEQUENT STATE D gt NOTE 3 INT FAST FL MEANS INTERMITTENT FAST FLASH Table 1 Alarm Sequence Chart Power Supply Card Description The power supply card provides 24 VDC and 12 VDC for use within the unit Seekirk Inc A1600 User Manual pg 10 Seekirk Inc Power Supply Types Figures 7 displays the various types of pow
5. is recommended to twist wire pair the control wiring 2 Connect Input Power Wiring to the Annunciator Connect power source cable to terminal strip TB3 labeled INPUT POWER which is located on the terminal board at the rear of the unit a If the input power source is a DC voltage then insure proper polarity is observed during hookup b Re inspect the power hookup wiring connections and also insure that the voltage rating selected for the unit matches the voltage rating of the applied source voltage before applying power to the unit The input voltage rating for the unit can be found on the model serial number label located on the side of the unit 3 Apply Power If any display windows are illuminated then press the ACK and RESET control pushbuttons to extinguish the displays 4 Annunciator Test Referring to table 1 alarm sequencing chart operate the control pushbuttons in the following sequences Seekirk Inc A1600 User Manual pg 3 Seekirk Inc a TEST All illuminated displays shall flash and the main alarm relay contacts change state b ACK Depending on the alarm sequence specified by the customer The illuminated displays shall either extinguish remain on or a change in flash rate The main alarm relay returns to the normally de energize contact state c RESET This control pushbutton is not present for sequences not requiring reset All illuminated displays shall extinguish 4 Remove Power 5 Connect
6. 7 Internal Arrangement of Primary Circuit Ca lt ___ jj_j j jjvvj j j jljl lT yit jyki 7 Card Insertion Location 7 Point Logic Card ___ j 8 Description 8 Configuration Jumper or Dip Switch Selectors 8 A1600 Standard Alarm Sequencing 10 Power Supply Card LL L k_ yj jjoj v r uo uj rxaw v k k k Divkjjkjy j U L LjEj jHMY0 Description 10 Power Supply Types 11 Internal Arrangements of Power Supplies 11 Switch Interface Alarm Relay Card ______ ee ee ees V Description 12 Alarm Relay N O N C Selection 12 Electrical Specifications 13 Dimensional Information 14 Window Engraving Information 15 Seekirk Inc A1600 User Manual pg 2 Seekirk Inc Unpacking and Handling Immediately upon receipt of the unit the packing list should be examined to assure that the unit received corresponds with the system ordered as well as inspecting for any parts shortage Examine the unit for any physical damage paying particular attention to the following 1 Examine the enclosure for any concealed damages The painted surfaces should be free of marks and scratches 2 Insure that all terminal barrier strips screws should be properly secured 3 Insure that all plug in components such as relays and printed circuit boards are properly seated 4 Insure that the unit is free of all restraining i e tape and loose packing material before power is applied If any evidence of physical damage due to improper han
7. C AUX Relay Contacts AUX Relay Contacts Power Input Term inal Main Alarm Relay Dry Contacts Out External Pushbuttons Point Module Relay Module wi Point Card Field Contacts Typical N O or N C AUX Relay Contacts AUX Relay Contacts Field Contacts Typical N O or N C AUX Relay Contacts AUX Relay Contacts Figure 2 Rear Panel View of Terminal Connections Example Seekirk Inc A1600 User Manual pg 6 Seekirk Inc Description of Circuit Cards Internal Arrangement of Primary Circuit Cards Refer to figures 1 and 8 for detailed information on the location of the circuit cards within the A1600 unit Card Insertion Location 1 Point card is inserted at the center position connector within the module Although the connector is slightly off center it is still possible to insert the card incorrectly When inserting the point card insure to note the direction of the components as shown in figure 1 2 Power supply card is inserted at the left most matching female connector within the module Since the power supply card location varies to the unit configuration specified by the customer Refer to the accompanying drawing s supplied with the unit for the location of the power supplies 3 Alarm relay card is located at the lower right most position of the unit as viewed from the front The alarm relay card is inserted at the right most connector within the module Alarm Relay Card Po
8. Minimum of 2500 VAC Withstand Test Insulation Input protection Metal Oxide Varistor Max clamping voltage 360 Volts 2 0 Amps during a current pulse of 8 20 uSec Auxiliary Relay Ratings Max switching voltage 200 VDC Max switching current 1 0Amps Max power rating 10 VA Relay type SPST Jumper DIP switch selectable for either NO or NC Alarm Relay Ratings Max switching current 2 0 Amps 28 VDC 1 0Amp 120 VAC Relay type SPDT Jumper Selectable for either NO or NC Operating Temperature and Humidity Range 32 to 120 degrees F 0 to 49 degrees C 0 90 RH non condensing Seekirk Inc A1600 User Manual pg 13 Seekirk Inc Dimensional Information TYPICAL 3 X 3 EXISTING PANEL KAL d MODULE NOTE 3 OR RACK MOUNT PLATE REAR OF Al600 7 Bi PB Eelay amp Comm 2 3 Non Pushbutton 1 and 2 Points Only PANEL CLAMP TYPICAL 9 25 ae r Number of 3 x3 Modules Overall Dimensions Inches 4 75 __ i 9 75 High or Wide H or W Cutout HC or WC 4 250 arar Note 7 250 6 875 j 10 250 9 875 1 For location reference of a given 3 x 3 module the first number 13 250 12 875 is the horizontal row the second number is the vertical column 16 2507 Ley Location 1 1 is always the top left hand module as viewed from t
9. Seekirk Inc A1600 Window Annunciator Installation Instruction Manual Copyright 2008 Seekirk Inc User Manual Version 1 0 Latest Revision 27 May 09 Seekirk Inc Product Warranty Seekirk Inc warrants that the apparatus delivered will be of kind and quality described in the order of contract In connection with the apparatus sold Seekirk agrees to correct any defect s in workmanship or material which may develop under proper or normal use during the period of one year from the date of shipment by repair or by replacements of the defective part s freight paid by customer both ways and such correction shall constitute a fulfillment of all Seekirk liabilities in respect to said apparatus In no event shall Seekirk be liable for consequential damages Proprietary Notice The information contained in this instruction manual is the property of Seekirk Inc Its use is conditioned upon the user s agreement not to copy or reproduce the information or drawing s to reproduce the material described therein or for any other purpose without written permission from Seekirk Inc Technical Support Seekirk Inc 2420 Scioto Harper Dr Columbus OH 43204 3480 Tel 614 278 9200 Fax 614 278 9257 seekirk seekirk com Seekirk Inc A1600 User Manual pg 1 Seekirk Inc Table of Contents Unpacking and Handling 3 Wiring Hookup and Startup Procedure 3 Description of Circuit Cards
10. dling by the carrier is noted then if possible save both the shipping box and packing material for use in returning the unit back to the factory and then notify the carrier on how to file a claim Seekirk Inc should be notified as to the specific equipment and the nature and extent of damage Include as much information as possible such as your purchase order number Seekirk s internal SOR number model number and serial number Such information should appear on the packing list Any claim for shortage defects or errors in shipment must be made in writing within 10 days of receipt WARNING When handling any of the A1600 printed circuit boards precautions must be taken to ensure the working area is suitable for handling electrostatic sensitive devices Wiring Hookup and Startup Procedure CAUTION The following procedures are for functional operation only Under no circumstances are voltage breakdown tests or insulation resistance tests to be performed without first consulting the factory Such tests may result in serious component damage due to the effects of stray capacitive coupling unless proper procedures are followed DANGER VOLTAGES DANGEROUS TO LIFE ARE PRESENT WHEN POWER IS APPLIED TO THE UNIT 1 Connect External Pushbutton Controls The TEST ACK and RESET controls may be wired for remote access Refer to figure 2 wiring diagram NOTE To reduce the effects of any induced external electrical noise into the controls it
11. er supplies used as required by the customer specified input supply voltage The 24 and 48 VDC power supplies are protected from accidental input supply over voltage If an over voltage condition is encounter disconnect the power supplied to the unit and allow the unit to remain disconnected for a time period greater then one minute to allow the power supplies resettable fuses to recover before connecting the correct input supply voltage to the unit Internal Arrangements of Power Supplies For one two and four alarm points per point card the power supplies are arranged in groups of three point cards per power supply For three alarm point per point card the power supplies are arranged in groups of two point cards per power supply Refer to the drawing s supplied with the unit to locate the positions of the power supplies distributed through out the unit 24VDC IN Power Supply 4BVDC_24V0C 24V0C 12VDC Di lt as a 9 9 Pover Supply f Setkirk Inc Columbus Ohio Rer Copyright 1993 1905 2006 260020195 i L or Tle salen 24V0G l 12V0C pe terro Power Supply ap Soekirk inc Cokimbus Ohio 6s Rev 1 1 Copyright 1993 1995 2006 260020195 Figure 6 Power Supplies Types Seekirk Inc A1600 User Manual pg 11 Seekirk Inc Switch Interface Alarm Relay Cards Description Interfaces the front panel switch controls TEST ACK and RESET to the point cards as well as provide the main a
12. he front 19 250 18 875 22 250 21 875 Se ae os 25 250 24 875 2 Max width for a rack mounted unit is 5 modules for a 19 rack or 28 250 27 875 7 modules for a 24 rack 31 250 30 875 Sea cela 3 Any 3 x 3 module may contain 1 2 3 or 4 windows in a bezel 40 250 39 875 43 250 42 875 Module Components Front CONTROL BEZEL amp LAMP UNIT TYPES SWITCHES SINGLE DUAL TRIPLE O O O LETTERS WITHIN WINDOWS INDICATE WINDOW AND REAR TERMINAL RELATIONSHIPS 1 2 3 4 5 6 7 8 CARD LOCATIONS FRONT VIEW BEZEL REMOVED POINT MODULE PUSHBUTTON RELAY MODULES DASHED LINES NUMBERS INDICATE CARD SLOT TEN POSITIONS 1 THRU 5 POWER SUPPLY ERTE 7 CARDS 4 POINT CAR D POINT CARD f SINGLE DUAL TRIPLE OR QUAD SINGLE OR DUAL RELAY CARD Figure 8 Seekirk Inc A1600 User Manual pg 14 Seekirk Inc Window Engraving Information STANDARD ENGRAVING INFORMATION ESER ii Use of one letter sizo for all win dows is recommended Other letter 1 4 16 5 PIPELINE PUMP sizes are available Use of letters B smaller than 3 16 is not recom A 270 FAILURE mended Ade Wi A 1 4 16 2 3 16 20 2 3 16 20 6 PIPELINE PUMP A 270 FAILURE vais GND FAULT DET 3 16 20 3 GROUND FAULT DET 3 16 9 3 1 4 16 5 Letter height A Characters and spaces per line Lines per window Other window and bezel colors ara available Consult factory for details Figure 9
13. larm relay contact for an external device Alarm Relay N O N C Selection Referring to figure 7 to select the polarity of the main alarm relay contact locate the jumper labeled JP1 on the Alarm Panel Interface Card Jumper JP1 consist of the labels NC and NO which refer to normally closed and normally open respectively in the non alarm condition This jumper is the wire jumper soldered on the printed circuit board and will require soldering tools to change the polarity of the main alarm relay contact For example to change the relay contact from NO to NC requires de soldering the wire jumper and re soldering the wire jumper at the solder pad labeled NC to the center solder pad of JP1 zi A nan k ey Rst D3 Aea JP8B JP2 12 t hess cT Tam Test es isee 2 C JP4 lt JP12 C6 eo opP7 o B e EJ sf Te a IP9 jjl ME 710 Bu ote waa oo Tre je Seekirk Inc Alarm Panel Interface Card Columbus Ohio C 26C020196 Rev 2 0 Copyright 2008 Hrn Silence Alarm Relay N O N C Contact Selector Jumper Figure 7 Alarm Relay Card Seekirk Inc A1600 User Manual pg 12 Seekirk Inc Electrical Specifications AC Power Voltage input range 110 or 220 VAC DC Power Voltage input range 24 48 or 125 VDC Field Contact Input Input voltage range 24 to 125 VDC or VAC Jumper DIP switch selectable for either NO or NC field contact input Optocoupler rating
14. lector S1 Device programmed mode dependent selector 1 Unit Equipped With Major Minor Alarm Relays Select Major Alarm Relay ON Select Minor Alarm Relay OFF N C IN NC Select Jumper ON NO Select Jumper OFF Position Flash Rate Aux Relay Contact N C N O Per Point Selector Aux Relay Contact N C OFF Aux Relay Contact N O ON 1 FCA 2 FCB 3 FC C 4 FC D Unit Lamp Flash Rate Selector Only one point card per unit is designated as providing the lamp flash rate for the unit Place this jumper in the ON position This designated pont card 5 located in the upper left corner of the unit as viewed from the front Figure 4 Point Card Jumper Selectors FC input Polarity N O N C Per Point Selector FC Input N C ON FC Input N O OFF Per Point Mode Selector Device programmed mode dependent selections 1 Standard Aux Relay Follows FC Input OFF Aux Relay Latches Until ACK ON 2 Unit Equipped Vith Major Minor Alarm Relays Select Major Alam Relay ON Select Minor Alarm Relay OFF Aux Relay Contact N O N C Per Point Selector Aux Relay Contact N C ON Aux Relay Contact N O OFF Unit Lamp Flash Rate Selector Only one point card per unit is designated as providng the lamp flash rate for the unit Place ths jumper in the ON position This designated pont card is located in the upper left comer of the unit as view ed from the front Figure 5 Point Card Jumper
15. wer Supply Card Point Card Bezel with Pushbutton Panel Figure 3 Internal Circuit Card Arrangements Seekirk Inc A1600 User Manual pg 7 Seekirk Inc Point Logic Card Description The point logic card provides the alarm sequencing lamp illumination and auxiliary and main alarm relay contact controls Configuration Jumper or Dip Switch Selectors Figures 4 board version 1 2 and earlier and 5 board version 2 0 or later shows the configuration jumper dip switch selectors for N O or N C selections for both the F C input and auxiliary relay contacts on a per point basis All point cards are capable of providing the system lamp flash rate However only the point card in the upper left corner of the unit as view from the front is designated to provide the lamp flash rate Only the designated point card shall have the jumper labeled Flash Rate in the ON position for all other point cards this jumper shall be in the OFF position The Point Mode jumper dip switch selection is used to modify the operating parameters on a per point basis For board version 2 0 or later only the Point Mode selector will allow the selection of either the auxiliary relay contact to follow the F C input or to latch the auxiliary relay contact until acknowledge This selection is standard for most alarm sequences Seekirk Inc A1600 User Manual pg 8 FC Input Polarit Seekirk Inc Per Point Mode Se