Home
eHealth SystemEDGE User Guide
Contents
1. 517 Interaction 3 Initializing Non defaulted Objects 520 Interaction 4 Making the Conceptual Row Available 521 Conceptual Row Suspension 0 cee cece cece eens 522 Conceptual Row DeletiOtics lt 0425 4caca2s0a4 50ad405e0 44 522 eHealth SystemEDGE User Guide 22 Table of Contents Appendix E Bibliography 025 Index 529 eHealth SystemEDGE User Guide Preface This guide supports SystemEDGE Release 4 2 Patchlevel 4 and later It describes how to install and use eHealth SystemEDGE on the following platforms e Sun Solaris SPARC Releases 2 6 through 2 10 e Sun Solaris x86 Releases 2 6 2 10 32 bit Sun Solaris 2 10 AMD64 e Microsoft Windows NT 4 0 Service Pack 6a or later Windows 2000 Windows XP x86 only and Windows 2003 x86 AMD64 EMT64 Itanium e HP UX PA RISC 11 0 111 and 11i v2 11 23 e HP UX Itanium 111i v2 11 23 e AIX Releases 4 3 3 and 5 1 through 5 3 32 and 64 bit Digital UNIX 4 0F and 4 0G and Tru64 5 1A and 5 1B e Red Hat Linux Releases 6 0 through 9 0 Red Hat Enterprise Linux AS 2 1 x86 Red Hat Enterprise Linux WS ES AS 3 0 Itanium x86 Red Hat Enterprise Linux WS ES AS 4 0 Itanium AMD64 EMT64 Itanium e SuSE Linux 9 x86 AMD64 EMT64 Itanium e SUSE Linux Enterprise Server 10 x86 AMD64 EMT64 Itanium When instructions for the operating systems differ this guide specifies to which op
2. 138 Configuring Support for Process Monitoring 139 Monitoring Applications Processes and Services 140 Monitoring Process Attributes 002 000 140 Monitoring Windows Services 02c eee eee eee 140 Configuring Support for Process Group Monitoring 141 Configuring Support for Log File Monitoring 141 Configuring Support for Windows Event Log Monitoring Windows Only 0 cece cece eee eee e rrenen 141 Configuring History Collection 0 0 c eee eee 142 Configuring User Group Permissions for Subprograms UND Only ce scaseces aedteeceubace tennessee apace n es 142 Configuring the SNMP Bind Address 02 006 143 Configuring Support for eHealth AIMs 143 Configuring Support for Linux Free Memory 145 Recommendations for Configuring Security 146 Using the SystemEDGE Control Panel for Windows 147 Starting the SystemEDGE Agent 149 Starting the Agent Manually 0 cece cece eee 149 Starting SystemEDGE on Windows Systems 149 Starting SystemEDGE on UNIX Systems 150 Starting the Agent Automatically at System Boot 151 Starting the Agent Automatically for Solaris Systems 152 Starting the Agent Automatically for Windows Systems 153 Starting the Agent Automatically for HP UX Systems 153 Starting the Agent Automatically f
3. eHealth SystemEDGE User Guide MN SEAGTUGD 007 November 2006 This documentation the Documentation and related computer software program the Software hereinafter collectively referred to as the Product is for the end user s informational purposes only and is subject to change or withdrawal by CA at any time This Product may not be copied transferred reproduced disclosed modified or duplicated in whole or in part without the prior written consent of CA This Product is confidential and proprietary information of CA and protected by the copyright laws of the United States and international treaties Notwithstanding the foregoing licensed users may print a reasonable number of copies of the Documentation for their own internal use and may make one copy of the Software as reasonably required for back up and disaster recovery purposes provided that all CA copyright notices and legends are affixed to each reproduced copy Only authorized employees consultants or agents of the user who are bound by the provisions of the license for the Software are permitted to have access to such copies The right to print copies of the Documentation and to make a copy of the Software is limited to the period during which the license for the Product remains in full force and effect Should the license terminate for any reason it shall be the user s responsibility to certify in writing to CA that all copies and partial copies of the Product
4. eHealth SystemEDGE User Guide 236 e Chapter 9 Host Resources MIB Host Resources Storage Group SNMP Table Displa i The Host Resources Storage group hrStorageTable lists the logical areas of storage allocated on the host system These storage areas include file systems and disk partitions that might be seen by an application rather than physical storage such as tapes and floppy drives This table is intended to be a useful diagnostic for out of memory and out of buffers types of failures In addition it can be a useful performance monitoring tool for tracking memory disk or buffer usage Figure 23 shows the output of the Host Resources Storage group from a Sun SPARC IPX Table hrStorageTable Path 1 3 6 1 2 1 25 2 3 1 Rows 5 Columns hrStorageType hrStoragelDescr hrStorageAl locationUnits hrStorageSize hrStorageUsed hrStorageAl locationFailures hrStorageRam Physical RAM al 24801280 4567040 0 hrStorageVirtual Memory Virtual Memory al 103849984 0 0 hrStorageF ixedDisk Disk partition dev sd0a 1024 15487 11080 0 hrStorageF ixedDisk Disk partition dev sd0g 1024 160423 130426 0 hrStorageF ixedDisk Disk partition dev sd0h 1024 123911 29154 0 Ok ert Figure 23 Sample Host Resources Storage Table Host Resources Device Group eHealth SystemEDGE User Guide The Host Resources Device hrDevice group contains several tables that provide information about the devices that are contained by the host syste
5. It instructs the SystemEDGE agent to monitor the Web server daemon httpd every 60 seconds eHealth SystemEDGE User Guide The Process Monitor Table 283 The attribute being monitored is the status of the process procAlive The current value of 3 indicates the process is running normally as far as the operating system is concerned If the process status goes to 4 or if the process stops running the agent will send a processStop trap to the management system The RowStatus column shows that this entry is active The Action column is null which indicates that the agent invokes no action when the process stops running The Flags value 0x00000100 instructs the agent to monitor the parent httpd daemon rather than child processes For more information on Process Monitor table flags refer to Process Monitor Table Flags on page 289 The Process Monitor Table The Process Monitor table provides information about each of the process attribute pairs or Windows service status pairs that the agent is currently monitoring Each row in the table represents the combination of a process or Windows service and a particular attribute of that process or service that the agent is monitoring For each entry the table provides the following types of information Attribute that is being monitored Interval at which the agent checks the attribute Process that the agent is watching Number of traps that have been sent
6. NOTE After you start the agent as described in this chapter you can use the diagsysedge exe program to verify that your agent is running For more information refer to Using diagsysedge exe on page 423 Starting the Agent Manually You can start the agent manually for both Windows and UNIX systems Starting SystemEDGE on Windows Systems For Windows systems you can manually start SystemEDGE from the command line the Services Control Panel or the SystemEDGE Control Panel 149 150 e Chapter 5 Starting the SystemEDGE Agent To start SystemEDGE from the command line 1 Enter the following net start sysedge To start SystemEDGE from the Services Control Panel 1 Select Start Settings Control Panel Administrative Tools Services 2 Right click SystemEDGE and select Start To start SystemEDGE from the SystemEDGE Control Panel 1 Select Start Settings Control Panel 2 Double click eHealth SystemEDGE and click Start Agent NOTE In the Windows XP Category View the SystemEDGE control panel is under Network and Internet Connections In theWindows XP Classic View the SystemEDGE control panel icon is at the main level of the display Starting SystemEDGE on UNIX Systems To start the SystemEDGE agent from the UNIX command line log in as root and then enter the following bin sysedge b Command Line Options for UNIX Systems This section describes the command line option
7. Table 5 Installation Instructions By Operating System Operating System Section of this Chapter Solaris Installing SystemEDGE on Solaris Systems on page 52 Windows Installing SystemEDGE on Windows Systems on page 59 HP UX Installing SystemEDGE on HP UX Systems on page 75 Linux Installing SystemEDGE on Linux Systems on page 80 Installing SystemEDGE on AIX Systems on page 82 Digital UNIX and Installing SystemEDGE on Digital Tru64 UNIX and Tru64 Systems on page 84 51 52 Chapter 2 Installing the SystemEDGE Agent Installing SystemEDGE on Solaris Systems This section describes how to install the SystemEDGE agent on Solaris systems See the Preface for a list of supported systems and versions These instructions explain how to install SystemEDGE in the opt EMPsysedge directory If you want to install SystemEDGE in a different directory refer to Installing SystemEDGE in a Non Default Directory for Solaris on page 58 System Requirements Before you begin installing the agent verify that your system meets the following requirements e CD ROM drive At least 8 MB RAM At least 4 MB free disk space Adding the SystemEDGE Agent Package The SystemEDGE agent for Solaris 2 x is distributed as a software package This distribution uses the standard pkgadd utility to install the agent To install the software 1 Login as root by entering su and then the root passwo
8. eHealth SystemEDGE User Guide 368 e Chapter 14 Configuring Windows Event Monitoring Viewing the NT Event Monitor Table with AdvantEDGE View If you are using AdvantEDGE View you can query a system for NT Event Monitor table information by selecting the system you want to monitor from the System list selecting NT Event Monitoring from the Configuration list and clicking the the Configuration icon For more information refer to the AdvantEDGE View Web Help Figure 54 shows a sample AdvantEDGE View Monitor table f Last Last Last p Log pyp pd Type Src Descr jAction Match Match Match indows cannot determine the user application a or 1 error 1 Usereny computer yf 0x20 name Return value 1722 Manitor blah o 00 00 o T Fal re 0x20 bian bian AN k noMatch no no 12345 eHealth test 0 00 00 O i 6 match sta fei 0x20 6 A TA sen EE E EEEN ry E Se EES Add NT Event Monitor Entry Description o n 17 days 5 18 36 174 30 test is 00 Li H Figure 54 Sample AdvantEDGE View NT Event Monitor Table Configuring the NT Event Monitor Table You can control which event logs the SystemEDGE agent monitors by adding deleting or modifying entries in the NT Event Monitor table eHealth SystemEDGE User Guide Configuring the NT Event Monitor Table 369 You can configure the NT Event Monitor table in one of these ways Dynamically Use SNMP com
9. ioj x Local Agent Configuration Information 3 Sistem Description Windows 2003 Database Server S System Contact memmy company com System Location Atlanta GA Rack 10 Read Community Read Wwirite Community Trap Destinations SSE00E mon sysedge lic Restart SystemEDGE After Config File Changes Service Control Logging Debug slisedge log diageysedge Status Started Stop Agent Star agent Version 4 2 Patchlevel 1 Release Notes User Guide Cloze eHealth SystemEDGE User Guide 148 e Chapter 4 Configuring the SystemEDGE Agent eHealth SystemEDGE User Guide You can use the SystemEDGE Control Panel to do any of the following Start and stop the agent View community strings and trap destinations Open the configuration and license files View the SystemEDGE log file Run the diagsysedge utility View the eHealth SystemEDGE User Guide and the eHealth SystemEDGE Release Notes Starting the SystemEDGE Agent This chapter explains how to start the SystemEDGE agent Before you do you must license the agent and configure it for your environment For more information refer to Chapter 3 Licensing the SystemEDGE Agent and Chapter 4 Configuring the SystemEDGE Agent To start the agent manually refer to the next section Starting the Agent Manually To start the agent at system boot refer to Starting the Agent Automatically at System Boot on page 151
10. 0x00000002 Do not send traps for this entry This flag bit overrides any other flag bit with respect to traps 0x00000004 Do not attempt to reinitialize this entry By default if the monitored log file is ever unavailable the agent will periodically try to reinitialize this table entry Setting this bit disables automatic reinitialization 0x00000008 Do not record events for this entry in the syslog facility Setting this bit will not affect trap sending nor action execution On Windows systems the agent does not log events to the agent s log file sysedge log if this bit is set When events occur frequently it is useful to disable event logging 0x00000010 Send continuous logMonEntryNotReady traps for this entry every time the agent attempts to reinitialize logfile monitoring and fails The agent s default behavior is to send a single logMonEntryNotReady trap when the log file that is being monitored ceases to exist or when an error accessing that log file occurs The agent periodically attempts to reinitialize the entry Enabling this feature causes the agent to send an additional logMonEntryNotReady trap each time reinitialization fails 0x00000020 Do not pass SystemEDGE arguments to action scripts or programs SystemEDGE normally passes default action parameters that indicate the trap type description field and so on This flag disables the passing of those arguments For more information refer to Log Monitor Table Actions on
11. Current attribute value eHealth SystemEDGE User Guide 284 e Chapter 11 Configuring Process and Service Monitoring Columns of the Process Monitor Table Table 37 describes the columns of the Process Monitor table For a complete description of the Process Monitor Table refer to the Systems Management MIB specification empire asn1 in the doc subdirectory of the SystemEDGE agent distribution Table 37 Columns of the Process Monitor Table Page 1 of 4 Column Name Permissions Description Only Integer 1 to MAXINT that indicates the row index for this entry pmonDescr Read Write Quoted string that is 0 to 128 characters in length and that normally contains a description of the process and attribute that the agent is monitoring as well as a severity level pmontInterval Read Write Integer value 30 to MAXINT that indicates how often in seconds the agent should perform this monitoring For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds pmonSampleType Read Write Either absoluteValue 1 or deltaValue 2 this value indicates whether the agent should sample the attribute s absolute value or take the difference between successive samples For example use deltaValue to monitor counter attributes because it provides the rate of change Use absoluteValue to monitor gauges because it provides the object s exact value pmonAttribute Re
12. NOTE Configuration file directives in sysedge cf take precedence over entries in sysedge mon If for example a Process Group Monitor table entry is contained in sysedge mon at index 10 and a configuration file directive is added to sysedge cf at index 10 for the Process Group Monitor table the entry defined in sysedge cf replaces the entry in sysedge mon Monitoring Monitoring a Process Group 329 Initial Configuration During Startup On startup the agent reads the sysedge cf file You can use this file to specify which MIB variables you would like SystemEDGE to monitor You can do so through the watch procgroup configuration file directive You can identify the process group to be monitored through a regular expression that matches the process name and optionally its arguments a Process Group You can use the watch procgroup directive to monitor a process group as follows watch procgroup regexp index flags interval description action Table 49 describes the parameters for watch procgroup Table 49 watch procgroup Parameters regexp Quoted string that specifies the regular expression to apply when attempting to match a process name and optional arguments Row index to use for this entry interval Specifies any additional non default behavior to apply to this entry Specify all flags as hexadecimal numbers for example 0x0000 Interval that indicates how often in seconds the agent monito
13. On Solaris 2 x systems the SystemEDGE agent failed to open the var sadm pkg directory for inspection of locally installed software packages Check that the var sadm pkg directory exists and that the SystemEDGE agent has permission to read it This problem can occur if you are running the SystemEDGE agent as a user other than the root user If you do not correct this error the SystemEDGE agent will continue to operate but will not be able to support the Host Resources Installed Software table eHealth SystemEDGE User Guide 450 e Appendix A Error Messages failed failed failed failed failed eHealth SystemEDGE User Guide to open config file X The SystemEDGE agent failed to open the specified configuration file x Verify that the x file exists and that it is readable by the SystemEDGE agent The SystemEDGE agent will not operate until you fix this problem to open ioconfig Upon startup the SystemEDGE agent attempts to discover the devices contained in the underlying system using any operating system support that is available This error message indicates that the SystemEDGE agent could not properly read the HP UX file etc ioconfig and will therefore attempt to discover devices without the operating system s help to open ip for mibe On Solaris 2 x systems the SystemEDGE agent needs access to the dev ip file in order to properly support MIB II Check that the dev ip file exists and that it is readable by
14. eHealth SystemEDGE User Guide Configuring the History Control Table 385 You can configure the History Control table in one of these ways Dynamically Use SNMP commands from a management system such as AdvantEDGE View to modify the table For more information refer to Dynamic Configuration During Operation on page 386 e Atstart up initialization Specify the entries for the History Control table in the SystemEDGE agent configuration file sysedge cf For more information refer to the next section Initial Configuration During Start Up Initial Configuration During Start Up On startup the SystemEDGE agent reads the sysedge cf configuration file and uses the emphistory directive to specify initial entries to the History Control table You can specify MIB object for the agent to monitor by adding appropriate entries to sysedge cf Using the emphistory Command You can use the emphistory keyword to add entries in the History Control table as follows emphistory index interval objid buckets description eHealth SystemEDGE User Guide 386 Chapter 15 Configuring History Collection Table 73 describes the parameters of the emphistory command Table 73 emphistory Command Parameters index Row number in which the agent will create the entry interval Interval in seconds at which the agent will sample the object s value The interval must be a multiple of 30 seconds objid Object identifier that
15. Before you add your own extensions carefully review the examples in this chapter and in the Systems Management MIB For clarity these examples include the appropriate configuration file extension commands You can add these extensions to your etc sysedge cf UNIX or SystemRoot System32 sysedge cf Windows file to make them available to the SystemEDGE agent DNS Domain UNIX Only The following extension object returns the DNS domain name of the underlying system as opposed to the Network Information System NIS domain name extension 1 OctetString ReadOnly opt EMPsysedge contrib getextension sh The instance identifier of this object is 1 3 6 1 4 1 546 14 1 0 NIS Domain Name UNIX Only The following extension object returns the NIS domain name of the underlying system as opposed to the DNS domain name extension 2 OctetString ReadOnly opt EMPsysedge contrib getextension sh The instance identifier of this object is 1 3 6 1 4 1 546 14 2 0 eHealth SystemEDGE User Guide Writing Extension Scripts 397 Remote Pinger UNIX and Windows The following extension objects allow you to instruct the SystemEDGE agent to ping a remote host from the host where the agent is running This can be a useful tool for diagnosing network connectivity problems It is also a good example of how to use SNMP Set operations with extension variables For UNIX systems enter the following in the etc sysedge cf file extension
16. Monitor Page fault Rate The values in this example are defined as follows e numPageFaults 0 is the OID for the numPageFaults counter object contained within the Systems Management MIB e 15 indicates that the entry is index 15 in the Monitor table eHealth SystemEDGE User Guide Threshold Monitoring Examples 269 The flags field of 0x00500500 does the following Configures the agent to send monitorClear Traps when the expression transitions from True to False Specifies that the agent should send at most x consecutive monitorEvent traps and then send no more until the entry resets itself Specifies that x 5 That is the agent sends 5 consecutive monitorEvent traps and then stops sending traps until the entry resets itself 60 indicates that the interrupt rate should be sampled every 60 seconds e delta tells the agent to measure the rate at which the number of interrupts has changed Because this object is a counter delta is an appropriate value for this entry s sample type e 1000 is the value against which the current number of interrupts is compared e indicates that no action is specified Figure 37 shows how the agent would send and clear traps based on this monitor directive Sample Trap Sent Sample No Trap Sent E Sample Clear Trap Sent vane Flags 0x00500500 Threshold Tir Figure 37 Monitoring the System s Page Fault Rate eHealth SystemEDGE
17. s syslog messages to the local1 facility Add this entry near the top of the sysedge cf file to redirect any syslog messages that are generated by errors in sysedge cf syslog _facility locall Configuring Alternative Syslog Facilities Windows Only eHealth SystemEDGE User Guide On Windows systems the SystemEDGE agent logs all syslog messages to the SystemRoot system32 sysedge log file by default That file size is unlimited However you can use the syslog_logfile directive to specify an alternative sysedge log location and file name and to place limits on the size of that log file and the number of old log files that the agent saves Use the syslog_logfile directive as follows syslog_logfile filename size number The variables are defined as follows e filename is the complete path to the desired log file e size is the maximum file size in KB number is the number of log files to preserve for historical purposes A minimum of two files is recommended Configuring Support for Agent Debugging 135 For example to instruct the SystemEDGE agent to log messages to the file C sysedge sysedge log creating up to two log files with a maximum size of 20 KB each add the following to the sysedge cf file syslog_logfile c sysedge sysedge log 20 2 Configuring Support for Agent Debugging By default the SystemEDGE agent logs all syslog messages of priority LOG_INFO or lower Lower priority levels signify greater i
18. 0 N1756 ru rucru rak staff BEE validis 1 1 Dirar ru rucru rak staff BEE validis 2 2 N1758 ru rucru rak staff BEE validis a Ok estas Figure 9 Systems Management MIB Shared Memory Table Deleting an Interprocess Communication When you are performing SNMP The IPC tables provide you with the power to delete message Set operations use a community queues shared memory segments and semaphores using an name that allows you read write SNMP Set operation Each of these tables contains a column access that acts as a Delete button setting the column to the value of delete 1 causes the agent to destroy that instance of IPC usage The Delete button objects are named queDel for the Message Queue table shmemDel for the Shared Memory table and semDel for the Semaphore table eHealth SystemEDGE User Guide 182 e Chapter 7 Systems Management MIB Message Buffer Allocation and Usage Statistics Use the Message Buffer Allocation table to discover how your system is using message buffers mbufs and how many buffers have been allocated for each use In addition you can obtain statistics for the number of times mbuf requests were denied or delayed which can help you track down message buffer shortages Table 19 describes the MIB objects of the Message Buffer Group Table 19 Message Buffer Group MIB Objects numMbufs 1 Total number of message buffers contained in the 608 message bu
19. Command line Utility Error Messages 479 emphistory WSAStartup failed On Windows systems emphistory was unable to initialize the WinSock library and could not communicate with the targeted SystemEDGE agent The requested action therefore was not performed emphistory internal error please report An internal SNMP library error has occurred within the program Report this error to Technical Support by sending an e mail to support concord ca com Set to empireHistoryCtriTable failed emphistory failed to perform an attempted SNMP Set operation to create delete or modify a row in the SystemEDGE agent History Control table The requested action therefore was not performed This error can occur because of an invalid community string or a community string without write access unknown command The requested command passed to emphistory on the command line was invalid so no action was performed nteventmon Error Messages This section describes error messages that may be generated by the nteventmon utility cant resolve address for The address or hostname provided to nteventmon could not be resolved to a valid IP address so the requested action was not performed Verify that the hostname has a valid address through tools like host or nslookup eHealth SystemEDGE User Guide 480 e Appendix A Error Messages eHealth SystemEDGE User Guide GET failed nteventmon first attempts to verify that the target machine i
20. Enabling this feature instructs the agent to wait until the xth consecutive occurrence of an event before sending processThreshold traps Once the xth event has occurred the agent will send processThreshold traps for each subsequent consecutive True expression evaluation If the threshold expression transitions from True back to False the row resets itself and the agent begins counting events from zero This flag also applies to action execution You can specify the value of X is specified through the flag value field Event logging is unaffected by this flag bit For an example refer to Figure 44 on page 296 eHealth SystemEDGE User Guide 294 e Chapter 11 Configuring Process and Service Monitoring Table 40 Process Monitor Table Flags Page 4 of 4 Fos towne 0x00004000 Monitor a process group for X processes 0x00008000 Monitor the Windows service that matches the corresponding regular expression Setting this flag instructs SystemEDGE to monitor the procAlive attribute of the matching Windows service within the Windows service table It is not necessary to set this flag bit if you use the watch ntservice configuration file directive Ox 00000 Flag value 0x00100000 Oxfff00000 Several flag bits utilize a value x for sending traps and executing actions The value X is specified as the high order 12 bits of the flag field Flag bits utilizing this field are mutually exclusive For more information refer to Figure 39 on pag
21. Processes and Services The SystemEDGE agent can also monitor applications processes and Windows services by creating entries in the Process Monitor table You can dynamically add entries through an SNMP Set request while the agent is running or you can define them in the sysedge cf configuration file that the agent reads when it starts Monitoring Process Attributes The watch process configuration file directive automatically configures the agent to monitor a process attribute that you specify You identify the process to be monitored using regular expressions to match the process name and the attribute of the process that you want to monitor The SystemEDGE agent automatically determines the process ID for the specified process and then creates the appropriate entry in the agent s Process Monitor table When you use the watch process directive you do not need to know the process ID or to use SNMP Set requests to add an entry to the Process Monitor table For more information about creating entries in the Process Monitor table refer to Chapter 11 Configuring Process and Service Monitoring Monitoring Windows Services eHealth SystemEDGE User Guide The watch ntservice configuration file directive automatically configures the agent to monitor a Windows service to ensure that it is running You identify the Windows service that you want to monitor and the SystemEDGE agent automatically determines the service index from the
22. System Requirements Before you begin installing the agent verify that your system meets the following requirements NOTE If you are using Windows NT 4 0 you must be using Service Pack 6a or later If you are using an earlier service pack you will receive an error message when you attempt to start the SystemEDGE agent e CD ROM drive At least 8 MB memory At least 4 MB free disk space NOTE Do not install SystemEDGE into a directory that includes spaces in the pathname such as C Program Files If you do the agent will have difficulty locating and loading the eHealth AIMs eHealth SystemEDGE User Guide 60 e Chapter 2 Installing the SystemEDGE Agent Installing the Software with InstallShield Throughout this guide the terms Windows and Windows NT encompass Windows NT 4 0 Windows 2000 Windows XP and Windows 2003 Information The SystemEDGE agent for Windows is distributed as an InstallShield program named sysedge exe NOTE You can also install SystemEDGE from the command line as described in Installing the Software from the Command Line on page 74 If you have previously installed the agent from the command line you can upgrade using the InstallShield program However you cannot run the command line installation to upgrade an existing InstallShield installation If you have installed SystemEDGE with InstallShield and you want to upgrade from the command line you must uninstall the Inst
23. Table 54 describes the arguments for the watch logfile directive Table 54 Parameters for the watch logfile Directive index Row number of the entry to be created flags Hexadecimal flags for example 0x00001 that direct the additional behavior of this entry logFilename Complete path starting from root and file name of the log file to be monitored Note The file you monitor must be an ASCII based text file SystemEDGE does not support monitoring of other character sets such as Unicode You can determine a file s encoding by opening it in a text editor and selecting Save As The encoding is listed in the Save as type field logMonRegExpr Regular expression to apply when scanning the log file for matches You must enclose this value in single quotation marks For information about the rules for specifying regular expressions refer to the UNIX man page on egrep 1 logMonDescr Description for this entry It is a quoted string 0 to 128 characters in length and normally contains a description of the file that is being monitored as well as a severity level for this event logMonAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the regular expression is matched and a trap is sent If the string is empty or not specified the agent invokes no action for this entry watch logfile Examples This section pr
24. Table 9 Directories and Files for All Platforms Page 2 of 4 config continued sysedge mon S99sysedge Specially formatted text file specifying MIB objects and conditions that the agent will automatically monitor through its self monitoring features Solaris Only Shell script for starting and stopping the agent If you disabled the native SNMP agent through the installation process the installation script places this script in the etc rc2 d directory to start the agent automatically at system boot time HP UX Only Shell script for starting and stopping the agent If you disabled the native SNMP agent through the installation process the installation script places this script in sbin init d and links sbin rc2 d S990sysedge so that the SystemEDGE agent starts automatically at boot time If you did not disable the native SNMP agent during the installation you can do so by editing SnmpMaster SnmpMib2 and SnmpHpunix in sbin init d and changing the following statements as shown Change SNMP_MASTER_START 1 to SNMP_MASTER_START 0 Change SNMP_HPUNIX_START I to SNMP_HPUNIX_START 0 Change SNMP_MIB2_START 1 to SNMP_MIB2_START 0 Digital UNIX and Tru64 Only Shell script for starting and stopping the agent If you disabled the native SNMP agent through the installation process the installation script places this script in sbin init d and links etc rc3 d S99sysedge to it to start the agent autom
25. The SystemEDGE agent interprets all flags in hexadecimal base 16 notation eHealth SystemEDGE User Guide 364 e Chapter 14 Configuring Windows Event Monitoring Figure 53 shows the composition of the NT Event Monitor table flags field ntEventmonFlags Ws bits network byte order W__ 12 bits for flag value 12 bits table specitic tags amp bits global fags OMOIO HHH gt Of fH OOD FHF gt OOD EE HAF ChGHRARAROO gt CoghRARet Figure 53 NT Event Monitor Table Flags The flags value consists of three fields Field 1 Common table flags that are defined for all of the self monitoring tables This portion is the low order 8 bits of the flags Field 2 Table specific flags that are defined separately for each self monitoring table This field defines the next 12 low order bits after the common table flags For Windows event monitoring there are currently no table specific flags defined Field 3 Flags value reserves the 12 high order bits for an integer value for use in conjunction with table specific flags For Windows event monitoring there are currently no table specific flags defined NOTE The following sections define each flag bit You can combine flag values through logical OR operations eHealth SystemEDGE User Guide NT Event Monitor Table Flags 365 Table 65 describes the common table flags for the self monitoring tables Table 65 Common Monitor Table Flags Page 1
26. Windows distribution directory enter the following in the sysedge cf file sysedge_plugin c sysedge plugins topprocs dll NOTE If you selected the option for configuring Top Processes during the SystemEDGE installation this line was automatically added to the sysedge cf file For information about enabling other AIMs refer to the user guide for that AIM eHealth SystemEDGE User Guide Configuring Support for Linux Free Memory 145 Configuring Support for Linux Free Memory Linux free memory is calculated as total physical memory less memory in use By default memory in use includes system buffers and disk cache Cache and system buffers can be reclaimed by the operating system if memory is needed for processes For this reason some choose to view free memory as including memory that is used by the operating system for caching or system buffers The linux_freemem_include directive is used to include these values in the Linux free memory calculation The directive supports the following two options e buffers include system buffers in the free memory calculation e cached include cached memory in the free memory calculation At least one of the above options must be specified The options may be specified in any order and must be separated by one or more spaces For example to include both buffers and cached memory in free memory add the following line to sysedge cf linux _freemem_include buffers cach
27. a Watch Web Server Bt httpd 11 Watch SSH Server Bt sshd 2 Figure 17 Systems Management MIB Sample Process Group Monitor Table For more information about using the Process Group Monitor table refer to Chapter 12 Configuring Process Group Monitoring Log Monitor Table eHealth SystemEDGE User Guide The Log Monitor table enables you to dynamically configure the agent to monitor system log files for regular expressions For example you can configure the agent to monitor the var adm sulog log file for the regular expression su fail Whenever the agent finds a match it sends an SNMP trap to the configured management systems For more information about formatting the logMonMatch Trap PDU refer to logMonMatch Trap on page 222 Each row of the Log Monitor table represents the monitoring of a log file for a particular regular expression Figure 18 shows example entries for the Log Monitoring table History Table 205 SNMP Table Display Table logMonitorTable Path 1 3 6 1 4 1 546 11 1 1 Rowst4 Columns 7 logMonitorLogFile logMonitorRegularExpression logMonitorNumberTraps logMonitorLastTrap logMonitorLastMatch logMonitorSta fusr adm sulog su 0 Od 07030 activet1 gt fvar log daemon log su fail 0 Od O 0 0 active 1 gt tmp testprag log start 2 Sd 1779 53 program starting active 1 tmp testpraog log stop 1 5d 1739353 program stopping active 1 gt a el e B5 OK esta History T
28. but the agent will not scan the log file for the regular expression unless the entry s status returns to active 1 edgewatch 127 0 0 1 private logfile setstatus 5 notInService Removing Log Monitoring Entries To stop the self monitoring of a log file you must remove the appropriate entry from the Log Monitor table Log Monitor table entries are stored in the sysedge mon file which ensures that they will not be lost when the SystemEDGE agent restarts The watch logfile directives in the sysedge cf file create a Log Monitor entry whenever the SystemEDGE agent starts This row creation results in a new Log Monitor table entry that will be stored in sysedge mon Thus permanent removal of a Log Monitor table entry requires two steps 1 Remove the entry from the sysedge cf file 2 Remove the entry from the Log Monitor table Removing Entries from the sysedge cf File If you configured a Log Monitor table entry by adding a watch logfile directive to the sysedge cf file you must manually delete it from that file as part of removing the entry from the table If you do not remove the sysedge cf directive the entry will be recreated the next time the SystemEDGE agent starts eHealth SystemEDGE User Guide 350 e Chapter 13 Configuring Log File Monitoring Removing Entries with the edgemon Utility To remove a log file monitoring entry from the Log Monitor table use the edgemon utility to delete the entry The following example delete
29. column of the same conceptual row to be modified Conceptual Row Deletion eHealth SystemEDGE User Guide For deletion of conceptual rows a management protocol set operation is issued which sets the instance of the status column to destroy This request may be made regardless of the current value of the status column e g it is possible to delete conceptual rows which are either notReady notInService or active If the operation succeeds then all instances associated with the conceptual row are immediately removed Conceptual Row Deletion 523 SYNTAX INTEGER The following two values are states these values may be read or written active 1 notInService 2 The following value is a state this value may be read but not written notReady 3 The following three values are actions these values may be written but are never read createAndGo 4 createAndWait 5 destroy 6 eHealth SystemEDGE User Guide Bibliography This appendix lists related works that may be helpful when you are using the SystemEDGE agent Bach M J 1986 The Design of the UNIX Operating System Prentice Hall Carpenter G and Wijnen B 1991 SNMP DPI Simple Network Management Protocol Distributed Program Interface Request for Comments Proposed Standard RFC 1228 Internet Engineering Task Force Obsoleted by RFC1592 Case J D Fedor M Schoffstall M L and Davin C 1990 Simple Network Management Prot
30. description 226 enabling in Process Monitor table 293 processStart eHealth SystemEDGE User Guide description 224 disabling in Process Monitor table 293 processStop description 223 setting in Process Monitor table 292 processThreshold 225 supported by SystemEDGE agent 215 troubleshooting agent not responding to SNMP requests 425 agent not running 430 diagsysedge exe 423 error messages 439 failed bind call 433 licensing 429 management system not receiving SNMP traps 428 obtaining diagnostic information about the agent 423 required system patches 437 restarting processes 436 SNMP traps 436 SystemEDGE agent 423 tool 423 trap messages 436 updating sysedge mon 433 verifying that the agent is running 423 426 Tru64 installing SystemEDGE 84 platform support 23 removing SystemEDGE 103 SNMP agent 163 system requirements 84 U uninstalling SystemEDGE AIX 102 Digital UNIX 103 HP UX 101 Linux 102 Solaris 98 Tru64 103 Windows 98 unmounting devices 168 unsupported Windows performance data types 407 updating sysedge mon file 433 User table Systems Management MIB 172 using edgemon utility 274 edgewatch utility 345 eHealth application insight modules 39 eHealth Service Availability 37 emphistory utility 387 extension variables with management software 399 Live Health 42 ntRegPerf variables with management software 410 performance registry variables 405 sysvariable utility 426 watch procgroup
31. extension scripts The agent can directly execute those batch files However batch file functionality is severely limited Use Perl and other scripting languages for Windows instead Testing Your Script An Example After you create an extension script test it at the command line The following example creates an OctetString extension on a UNIX system tests its output and then uses SNMP to return the value from the script 1 Add the following line to etc sysedge cf extension 1 OctetString ReadWrite opt EMPsysedge debugext sh On Windows systems you must call the interpreter in your action script command For example enter perl exe myscript pl NOTE This example tests an extension script that is an OctetString It is valid for UNIX operating systems 2 Test the setup by entering the following at the command line debugext sh 1 SET mycommandlinetest your_output_here debugext sh 1 GET your_output_here Enter the following at the command line to create a file called myset txt echo 1 3 6 1 4 1 546 14 1 0 04 debugSetString gt myset txt eHealth SystemEDGE User Guide Using Extension Variables with Your Management Software 399 You now have a file called myset txt You are setting the OctetString 04 debugSetString to the OID 1 3 6 1 4 1 546 14 1 0 4 Issue the SNMP Set by entering the following snmpset private 127 0 0 1 lt myset txt 5 Retrieve the value of your debugSetString
32. monitor action execution failed The SystemEDGE agent failed to execute a Monitor table action command The agent will continue to monitor entries and will attempt to perform action commands when monitor table expressions evaluate to True eHealth SystemEDGE User Guide SystemEDGE Agent Error Messages 459 monitor entry X not ready The SystemEDGE agent has sent a Monitor table trap message that indicates that entry x is notReady The agent will no longer evaluate Monitor table entry x but will continue to perform monitoring on all other entries A Monitor table entry can become notReady when an error occurs while accessing a MIB variable monitor trap Index X The SystemEDGE agent has sent a Monitor trap message that indicates that Monitor table row x has evaluated to True If the entry contained an action command the agent has executed it The agent will continue to monitor this entry and will send additional trap messages when the entry reevaluates to True monprocess requires regular expression A monprocess statement in the SystemEDGE agent configuration file did not contain a regular expression monprocess statements must contain a Monitor table index number that identifies which monitor table entry to use and a regular expression that identifies which process to monitor The SystemEDGE agent will ignore the error and will continue to parse the configuration file nlist of unix failed The SystemEDGE agent was unable t
33. pmonIndex 20 of the Process Monitor table eHealth SystemEDGE User Guide 310 e Chapter 11 Configuring Process and Service Monitoring e The flags field of 0x00a02400 instructs the agent to modify the default Process Monitor table behavior as follows x00000400 instructs the agent to send processClear traps x00002000 instructs the agent to send up to 10 consecutive traps and then send no more x00a00000 contains the flag value 10 for use with the directive in this example The sample type absolute instructs the agent to compare each sampled value to the threshold rather than to measure the difference delta between successive samples The greater than gt operator instructs the agent to compare the sampled procSize attribute against the value 35000 35 000 KB or 35 MB and to senda processThreshold trap when that threshold is exceeded Using the edgewatch Utility to Monitor Processes edgewatch is a command line utility that automatically configures the SystemEDGE agent to monitor processes log files and Windows event logs After you specify the particular process log file or Windows event log as well as the associated arguments the edgewatch utility issues an SNMP Set request to create the appropriate entry in the target agent s self monitoring table You can use the edgewatch utility for process monitoring as follows edgewatch hostname port timeout community process command Table
34. that are defined for your site eHealth SystemEDGE User Guide Using Windows Registry and Performance Variables with Your Management Software 411 Editing empire asn1 for ntRegPerf Variables Follow these steps to add your own ntRegPerf variables to the Systems Management MIB 1 Create and debug the relevant ntRegPerf entries in the agent s configuration file sysedge cf to include them 2 Edit empire asn1 to include new ntRegPerf MIB variables 3 Perform a test compile of empire asn1 to ensure there are no syntax errors This procedure is specific to your management system and its corresponding MIB compiler 4 Import the new empire asn1 file into your management system software This procedure is specific to your management system and MIB compiler NOTE If you do not reimport the MIB file your management system software will not be able to access he new MIB objects Editing a Separate MIB Specification for ntRegPerf Variables You can place ntRegPerf variables in a separate MIB specification file for ease of updating In this way you can save time and effort by making changes to a MIB specification file that is much smaller than empire asn1 instead of recompiling and reloading the entire empire asn1 file 1 Create and debug the relevant ntRegPerf entries in the agent s configuration file sysedge cf to include them 2 Edit your own MIB specification file for example ntregperf asn1 to include the new ntReg
35. you specified For sample actions refer to the contrib subdirectory of the SystemEDGE agent installation and to the SystemEDGE contributed information Web page on the eHealth Support Web site support concord com NOTE Do not use Windows batch files for actions they impose severe programmatic limitations and often do not work correctly with desktop applications Instead use a more powerful and flexible scripting language such as Perl or Visual Basic For more information about specifying actions refer to the following sections e Monitor Table Actions on page 255 e Process Monitor Table Actions on page 296 e Process Group Monitor Table Actions on page 326 e Log Monitor Table Actions on page 340 e NT Event Monitor Table Actions on page 366 eHealth SystemEDGE User Guide 36 e Chapter 1 Introduction SystemEDGE in Windows Clustered Environment eHealth SystemEDGE User Guide Clusters are groups of servers and other resources that function as a single system to enable high availability and shared workload Clusters can protect against failure of applications services and hardware including CPUs and disk drives The SystemEDGE agent can operate in a Windows cluster to monitor individual components on the physical servers in Windows clusters based on MIB objects in the Systems Management MIB empire asn1 SystemEDGE s NT Event Monitoring can be used to send a trap upon a cluster
36. 167 mqcnt file 96 multiple SNMP agents 157 N NEFS group 186 nhAddSysEdgeMonEntries command 40 nice value changing 175 eHealth SystemEDGE User Guide 538 e Index NT Cache Performance group 194 NT Event Monitor group 197 NT Event Monitor table actions 366 adding entries 508 AdvantEDGE View display 368 columns 360 configuring 368 default action parameters 366 description 360 event monitoring 357 examples monitoring log files 510 searching application log for specific events 372 searching application log for Web server messages 371 searching security log for failure events 371 flags 363 overview 141 removing entries 376 sample sysedge mon entries 510 watch ntevent directive 369 NT Memory Performance group 195 NT Page File Performance group 197 NT Registry and Performance Extension group 199 NT Registry group 191 NT Service group 192 NT System group 188 NT System Performance group 193 NT Thread group 190 ntdist pl 96 nteventmon utility error messages 479 nteventmon keyword 508 eHealth SystemEDGE User Guide ntRegPerf directive parameters 408 syntax 408 ntRegPerf group examples returning number of transmitted TCP segments 410 returning path to dump file 409 returning total number of current threads 410 overview 403 sample MIB group 404 unsupported Windows performance data types 407 valid variable types 404 ntRegPerf variables editing empire asn1 411 editing separate MIB specification 411 using with manag
37. 2 notReady 3 createAndGo 4 createAndWait 5 destroy 6 Normally a row is either active or notInService These values are identical in meaning to the SNMPv2 SMI RowsStatus textual convention For more information refer to Appendix E pgmonRSS Read Only Combined resident set size RSS of the group of processes The RSS for each process in the group is summed at each interval and stored in this variable Because RSS also includes shared memory the total RSS for a group could exceed total possible physical memory for the underlying system For more information refer to the processRSS variable of the Systems Management MIB in doc empire asn1 pgmonSize Read Only Combined size of the text data and stack segments of the group of processes The size of each process in the group is summed at each interval and stored in this variable Size includes shared memory so the total size for a group could exceed the total virtual memory for the underlying system For more information refer to the processSize variable of the Systems Management MIB in doc empire asn1 pgmonThreadCount Read Only Total number of threads for the group of processes The number of threads running in each process in the group is summed at each interval and stored in this MIB variable For more information refer to processNumThreads variable of the Systems Management MIB in doc empire asn1 eHealth SystemEDGE User Guide The Process Group Monitor Ta
38. 24 Documentation Conventions cece eee eee 25 Technical SUPP OF s20 c605 356 lt 4apadecenacenedan avauegen ss 26 Current SystemEDGE Product Information 26 Introduction 27 Introducing eHealth SystemEDGE 00 00 e eee 27 Microsoft Data Center Certification 065 27 Using eHealth SystemEDGE 0 0c cece eee eee 28 Supported MIBs 0 ccc cece eect eee karis 28 SystemEDGE Self Monitoring Features 31 Identifying Top Processes 00 c cece cence eee 33 Trach DRAS Serrone cade eens eau eanares cpeenees aa 34 Supporting Custom MIB Objects 00 eee eee 34 Supporting Windows Registry and Perfmon Extensions 34 Specifying Corrective Actions 0 0 cece eee ee eens 35 SystemEDGE in Windows Clustered Environment 36 Using eHealth AdvantEDGE View 002s eee eee 37 Using eHealth Service Availability 0000 37 Monitoring Voice and Call Quality 0 0 0 e eee 38 Using the eHealth Application Insight Modules 39 4 e Table of Contents Chapter 2 Using eHealth with eHealth SystemEDGE 40 Using eHealth Live Health Fault Manager with Cede System BOGE 22 54044 nusteeteenens ees Ea 42 Guidelines for Using the SystemEDGE Agent 43 Simple Network Management Protocol 47 SNMP Message Vy pests 300 shteee ie eioeewbewsea
39. 3 causes the agent to poll the swapCapacity variable percentage of swap that is in use every 15 minutes and to store the most recent 48 samples By storing 48 samples a management system needs to upload these samples only once every 12 hours that is 48 samples at 15 minute intervals provides 12 hours of coverage Table 25 shows the history samples that were stored in the History table as a result of the sampling configuration defined in the sample History Control Table 24 on page 206 Table 25 History Table Stored Samples Page 1 of 2 ee ee ee CC gt ea Od 0 0 0 Od 6 26 00 32204 Od 0 0 0 Od 6 26 30 32213 Od 0 0 0 Od 6 30 30 32224 eHealth SystemEDGE User Guide 208 e Chapter 7 Systems Management MIB Table 25 History Table Stored Samples Page 2 of 2 Od 2 0 0 Od 6 30 00 For more information about using the History Control table refer to Chapter 15 Configuring History Collection Disk Statistics Group eHealth SystemEDGE User Guide The Disk Statistics group provides disk I O statistics Each table entry provides the latest disk statistics for one disk The agent periodically every 60 seconds checks the status of the system data structures for each disk and records the values in the table Table 26 describes the Disk Statistics group MIB objects Table 26 Disk Statistics Group MIB Objects Page 1 of 2 diskStatsIndex Index in the Disk Statistics table diskStatsQueueLength Average number of
40. 44 describes the edgewatch parameters eHealth SystemEDGE User Guide Using the edgewatch Utility to Monitor Processes 311 Table 44 edgewatch Parameters hostname port timeout Specifies the hostname or IP address in dotted notation of the system on which the agent exists If the agent is running on an alternative UDP port for example 1691 specify that port number through a colon separator In addition you can specify an optional SNMP timeout value in seconds using a command separator community Specifies the community string that edgewatch uses in its SNMP requests to the agent Because edgewatch uses SNMP Set requests the community string should provide read write access to the target agent command Specifies the command and associated arguments Supported commands include the following add setstatus delete list Those commands are outlined in the next section eHealth SystemEDGE User Guide 312 Chapter 11 Configuring Process and Service Monitoring edgewatch Commands for Process Monitoring The edgewatch process monitoring commands and associated arguments are as follows add procAlive processname index flags interval description action add attribute processname index flags interval stype operator value GESCRIDLAON AOT On setstatus index status delete index Lise Table 45 defines the arguments to the edgewatch commands Table 45 edwatch Command Arguments Page 1 of 2 proc
41. 474 e Appendix A Error Messages Set to monitor table failed This message indicates that edgemon failed to perform an attempted SNMP Set operation to create delete or modify a row in the SystemEDGE agent Monitor table The requested action therefore was not performed This error can be caused by an invalid community string or a community string without write access SNMP Operation failed An error occurred while retrieving and parsing the Systems Management MIB Mounted Device table perhaps due to a dropped SNMP packet or a SystemEDGE agent error The operation may or may not have succeeded depending other error or information messages returned by edgemon unknown command An unknown command was passed to edgemon so no operation was performed edgewatch Error Messages eHealth SystemEDGE User Guide This section describes error messages that may be generated by the edgewatch utility AIX does not support procMonAttribute The Process Monitor attribute that was passed to edgewatch is not supported by the underlying AIX operating system on which the SystemEDGE agent is running The agent therefore does not create a Process Monitor table For a list of Process Monitor attributes that are not supported by AIX refer to the SystemEDGE Agent Release Notes Command line Utility Error Messages 475 Digital UNIX Tru64 does not support procMonAttribute The Process Monitoring attribute that was passed to edgewatch is not s
42. 489 logmon keyword 506 M mailaction sh file 96 Message Buffer Allocation table Systems Management MIB 182 message buffers monitoring 182 MIB Host Resources 29 MIB II 28 specification 97 supported by SystemEDGE agent 28 Systems Management 29 monitor directive monitor keyword 494 parameters 262 usage 261 Monitor table actions 256 adding entries through sysedge mon 494 AdvantEDGE View display 256 assigning entry rows 257 columns 247 configuring 258 default action parameters 255 description 247 disabling traps 254 edgemon utility 274 examples monitoring usr file system 272 monitoring 15 minute load average 266 monitoring 1 minute load average 264 497 eHealth SystemEDGE User Guide monitoring 5 minute load average 265 monitoring input packet rate 270 monitoring interrupt rate 267 monitoring number of processes 274 monitoring output packet rate 270 monitoring page fault rate 268 monitoring root file system 271 monitoring SNMP packets received 271 flags definitions 254 overview 252 monitor directive sysedge cf 259 overview 202 removing entries 279 sample sysedge mon entries 497 threshold monitoring 245 monitoring usr file system 272 15 minute load average 266 1 minute load average 264 1 minute load averagesysedge mon 497 5 minute load average 265 boot configuration 169 call quality 38 CPU statistics 211 devices 236 disk I O statistics 208 disk storage devices 239 DT processes 331 file
43. 50000 0x0 netscape active Adding Process Group Monitor Table Entries to the sysedge mon File 503 Adding Process Group Monitor Table Entries to the sysedge mon File Process Group Monitor table entries begin with the keyword procgroupmon They are delineated by open and closed brackets Table 88 describes the fields for Process Group Monitor table entries in the sysedge mon file Table 88 Fields for Process Group Monitor Table Entries Page 1 of 2 procgroupmon Beginning of the entry is marked by an open bracket pgmonIndex Integer 1 to MAXINT that indicates the row index for this entry The index is particularly important because SNMP does not directly support creation and deletion of MIB objects instead it creates and deletes them as side effects of SNMP Set operations This limitation means that the person creating or modifying Process Monitor table entries through the processmon command or by editing sysedge mon must know the exact MIB table index to use for row creation pgmonDescr Quoted string that is 0 through 128 characters in length and that normally contains a description of the process and attribute that the agent is monitoring as well as a severity level for this event pgmonInterval Integer value 30 to MAXINT that indicates how often in seconds the agent should perform this monitoring For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a mu
44. 6 bits global flags Ox 00 1HHHH gt Cf HHH OMQOO00 LHF gt OMDD0 TT TAF COGHRAAARIO gt Cpi Figure 39 Process Monitor Table Flags The flags value consists of three fields Field 1 Common table flags for the self monitoring tables of the Systems Management MIB This portion is the low order 8 bits of the flags field Field 2 Table specific flags that are defined separately for each of the self monitoring tables This field defines the next 12 low order bits after the common table flags Figure 40 on page 291 shows how these 12 bits are defined for the Process Monitor table Field 3 Reserved 12 high order bits for an integer value for use in conjunction with table specific flags This field defines the flags that are specific to the Process Monitor table The following sections explain each flag bit You can combine flag values through a logical OR operation Figure 40 shows the flags that are specific to the Process Monitor table eHealth SystemEDGE User Guide Process Monitor Table Flags 291 Doe 1 O0SHE Oc Ded Coc ALO Che AH Od CHE RH One Deke Cnc QA Qed H Al Ajal ATA AlA 4 Monitor parent process in process group Do not send Process Start traps for this table entry send Process Clear traps tor this table entry Match process name and arguments send traps for this table entry only alter x consecutive events have occurred cend up to X consecutive traps for this table entry Mon
45. Availability Web Help Monitoring Voice and Call Quality eHealth SystemEDGE User Guide eHealth for Cisco CallManager CCM and eHealth Voice Quality Monitor VQM are plug ins to the SystemEDGE agent that you can use with eHealth and AdvantEDGE View to monitor your Cisco CallManager systems and applications as well as voice quality and jitter on response paths For more information refer to the Web Help for CCM and VQM Using the eHealth Application Insight Modules 39 Using the eHealth Application Insight Modules The SystemEDGE agent provides a plug in architecture through which it can load optional eHealth AIMs when it initializes These eHealth AIMs previously called AdvantEDGE Point modules provide an extensible and flexible approach to supporting application specific semantic knowledge Table 3 lists the existing AIMs and the applications for which they provide management Table 3 eHealth AIMs eHealth AIM for Microsoft Microsoft Exchange application Exchange eHealth AIM for Microsoft IIS Microsoft IIS application eHealth AIM for Microsoft SQL Microsoft SQL Server application Server eHealth AIM for Apache Apache Web server eHealth AIM for Oracle Oracle database and application eHealth AIM for Check Point Check Point FireWall 1 FireWall 1 application eHealth AIM for Network Vital network services for UNIX Services for UNIX systems including Sendmail DNS Lightweight Directory Access
46. Description of how to use the sysvariable utility to query systems and exercise the agent walktree txt Description of how to use the walktree utility to retrieve specific MIB variables xtrapmon txt Description of how to use the xtrapmon utility to receive and log SNMP trap messages Directories and Files for All Platforms Table 9 describes the directories and files that the SystemEDGE agent installation creates for all platforms Table 9 Directories and Files for All Platforms ns 1 of 4 bin diagsysedge exe Diagnostic S for automating the collection of troubleshooting information for the SystemEDGE agent config Subdirectory that contains the configuration files that the SystemEDGE agent reads on startup To configure the agent for use in a local environment copy these files to etc for UNIX or to the system root directory for Windows and edit them to specify local values for items such as the following license key for this system communities system contact person system location and other configurable parameters and entries for the agent s self monitoring and history sampling tables sysedge lic Text file that contains the license key that enables the agent to run on this system sysedge cf Text file that contains local configuration parameters for MIB II system group values communities self monitoring and so on for the agent eHealth SystemEDGE User Guide SystemEDGE Agent Directories and Files 95
47. EMPsysedge eHealth SystemEDGE User Guide Uninstalling SystemEDGE for Linux Systems The SystemEDGE agent home directory contains a removal shell script Remove that removes all subdirectories and files under the SystemEDGE agent home directory but does not remove the home directory or the Remove script itself 1 Run the Remove script by entering the following Remove 2 Remove the agent s configuration files by entering the following commands one at a time rm etc sysedge lic rm etc sysedge cf rm etc sysedge mon Uninstalling SystemEDGE for AIX Systems Use the AIX smit utility to remove the SystemEDGE agent software package EMPsysedge 1 Run the smit utility by entering the following smit install remove 2 Select EMPsysedge rte from the list of software to remove 3 Remove the Remove script and the SystemEDGE agent s home directory typically named sysedge by entering the following commands one at a time rm Remove cd rmdir agent homedir Uninstalling the SystemEDGE Agent 103 Uninstalling SystemEDGE for Digital UNIX and Tru64 Systems Use the Digital UNIX or Tru64 setld utility to remove the SystemEDGE agent software package EMPsysedge Run the setld utility by entering the following setld d EMPSYSEDGE eHealth SystemEDGE User Guide Licensing the SystemEDGE Agent The SystemEDGE agent utilizes a host based license method which means that you can run copies of the agent o
48. Error Messages eHealth SystemEDGE User Guide error converting type skipping Variable bindings can be passed to sendtrap and then sent in an SNMP Trap PDU This message indicates that the variable type that was specified for one of the variable bindings was invalid An SNMP Trap PDU was sent but the corresponding variable binding was not included error converting value skipping Variable bindings can be passed to sendtrap and then sent in an SNMP Trap PDU This message indicates that the variable type that was specified for one of the variable bindings was invalid An SNMP Trap PDU was sent but the corresponding variable binding was not included error bad specific trap type The specific trap type that was specified to sendtrap was invalid soan SNMP Trap PDU was not sent Specific trap types must be greater than or equal to 0 error bad trap type The trap type that was specified to sendtrap was invalid so an SNMP Trap PDU was not sent Trap types must be greater than or equal to 0 error parsing arguments ignoring line The sendtrap utility encountered an error parsing a variable binding The utility ignored the offending line and sent the SNMP Trap PDU no more varbinds supported The maximum number of variable bindings was already read and placed in the SNMP Trap PDU to be sent All current and subsequent variable bindings will be ignored The last SNMP Trap PDU was however sent Command line Utility Error
49. For more information refer to the eHealth AdvantEDGE View User Guide Create a standard configuration for each group through AdvantEDGE View Template Management or manually in the sysedge cf file that is based on system roles for example one configuration for e mail servers and another for Web servers one for UNIX systems and another for Guidelines for Using the SystemEDGE Agent 45 Windows systems and so on Apply that configuration through AdvantEDGE View or by copying sysedge cf to each system that you are monitoring For more information about applying SystemEDGE Configuration templates refer to the eHealth AdvantEDGE View User Guide For more information about the sysedge cf file refer to Chapter 4 Configuring the SystemEDGE Agent Include meaningful information in the system location and contact field of your sysedge cf file For example include information such as Rack 0 Slot 1 Atlanta and e mail it yourdomain com Use a standard table of row indexes across your self monitoring tables For example use rows 10 000 to 10 999 across all self monitoring tables for threshold monitoring rows 11 000 to 11 999 for process monitoring and so on When defining these indexes and reserving rows keep in mind the following Use large ranges of index numbers for each type of monitoring to allow for growth Use standard index entries for specific types of monitoring entries For example always use row 10 0
50. Guide Log Monitor Table Actions 341 specify The default parameters are the same as the parameters provided in the SNMP traps sent for the Log Monitor table Table 53 describes the default parameters for Log Monitor table actions Table 53 Parameters for Log Monitor Table Actions trapType Type of trap being sent such as logMonMatchEvent or logMonNotReadyEvent logMonitorLogFile Note Name of the file that the agent is monitoring The file you monitor must be an ASCII based text file SystemEDGE does not support monitoring of other character sets such as Unicode You can determine a file s encoding by opening it in a text editor and selecting Save As The encoding is listed in the Save as type field logMonitorRegularExpression Regular expression that the agent is attempting to match for this entry logMonitorFlags Flags field in hexadecimal notation for example 0x0000 for this entry eHealth SystemEDGE User Guide 342 e Chapter 13 Configuring Log File Monitoring NOTE The agent logs action command invocations at the syslog level LOG_DEBUG It logs action command invocation errors at syslog level LOG_WARNING For more information about configuring syslog refer to Appendix B For information about starting the agent with its debugging options turned on refer to Chapter 5 Starting the SystemEDGE Agent Viewing the Log Monitor Table with AdvantEDGE View If you are using AdvantEDGE View you can quer
51. History Control table For more information about the History Control table refer to the Systems Management MIB specification empire asn1 in the doc subdirectory of the SystemEDGE agent distribution Table 70 Columns of the History Control Table Page 1 of 2 eee empireHistoryCtrlIndex Integer 1 to MAXINT that uniquely identifies the entry in the table empireHistoryCtrlDescr Text string that describes the data collection function defined by this entry empireHistoryCtrlInterval Integer value indicating how often in seconds the agent should sample the MIB variable Note The interval must be a multiple of 30 seconds empireHistoryCtrlObjID Complete object instance identifier of the MIB variable to be sampled Note that you must include the instance portion of the object identifier for example 0 for scalars The object instance must exist and must be contained within the Systems Management MIB For example any supported INTEGER based object in MIB II the Host Resources MIB or the Systems Management MIB is valid Objects should be of integer type including counter gauge integer or enumerated integer eHealth SystemEDGE User Guide 382 e Chapter 15 Configuring History Collection Table 70 Columns of the History Control Table Page 2 of 2 a empireHistoryCtrlObjType ASN1 SNMP type of the MIB variable that the agent is sampling empireHistoryCtrlBucketsReq Requested number of discrete samples to be saved in th
52. Is this acceptable eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 73 26 Click Yes When licensing completes the following dialog box appears Information InstallShield Wizard e InstallShield Wizard Complete Setup has finished installing Concord SpstemE DGE on your computer Eancel Back 28 Click Finish NOTE The only cases in which the system reboots after you install the agent are the following if you are running a Windows NT 4 0 operating system with a version of Windows Installer that is earlier than 1 10 or if you are running a eHealth SystemEDGE User Guide 74 Chapter 2 Installing the SystemEDGE Agent Windows 2000 system that does not include the Windows Installer service Use the Windows msiexec command to determine which version of the Windows Installer is running on your system Installing the Software from the Command Line eHealth SystemEDGE User Guide The SystemEDGE agent command line installation package for Windows is distributed as an executable named sysedge exe in the wincmd folder on the AdvantEDGE CD ROM NOTE You can also install SystemEDGE with InstallShield as described in Installing the Software with InstallShield on page 60 If you have previously installed the agent from the command line you can upgrade using the InstallShield program However you cannot run the command line installation to upgrade an existing InstallShi
53. Kernel Performance Statistics Use the Kernel Performance group to track the health and performance of the host s operating system Statistics that you can monitor include the following e Number of jobs that are waiting on disk I O and page I O e Number of jobs in the scheduler s run queue e Number of active jobs that are swapped out and the number that are sleeping e Number of current processes and open files e Statistics on paging context switching interrupts and page faults This group also includes a running percentage over 1 5 and 15 minute intervals of the time that the processor was not in an idle state For example you can detect that the host system is overloaded if the 15 minute average is continuously high and you can detect peak periods of CPU utilization by monitoring the 1 minute and 5 minute averages The following are the Kernel Performance Statistics MIB objects e cpulMin 1 e cpu5Min 2 eHealth SystemEDGE User Guide Kernel Performance Statistics 179 cpul5Min 3 runQLen 4 diskWaitNum 5 pageWaitNum 6 swapActive 7 sleepActive 8 memInUse 9 activeMem 10 numProcs 11 numOpenFiles 12 swapInUse 13 numSwitches 14 numTraps 15 numSyscalls 16 numInterrupts 17 numPageSwapIn 18 numPageSwapOut 19 numSwapIn 20 numSwapOut 21 numPageln 22 numPageOut 23 numPageReclaims 24 numPageFaults 25 loadAverage1 Min 26 loadAverage5Min 27 loadAverage15Min 28 totalSwapSpace 29 s
54. MIB object histCtrlMatchIndex Read Only You can use this MIB object with histCtr MatchDescr to match a particular entry description with its index number eHealth SystemEDGE User Guide 384 e Chapter 15 Configuring History Collection Viewing the History Control Table with AdvantEDGE View If you are using AdvantEDGE View you can query a system for History information by selecting the system you want to monitor from the System list selecting History Collection from the Configuration list and clicking the Configuration icon For more information refer to the AdvantEDGE View Web Help Figure 55 shows a sample AdvantEDGE View History Control table ee Interval Last 49 days Integer 20 18 11 06 0 00 03 swapCapacity Swap Cap 1 3 6 1 4 1 546 1 1 7 8 30 0 totalSwapSpace 49 days u pest ola 1 3 6 1 4 1 546 1 1 7 8 29 0 Integer 60 18 11 06 2 00 08 swapCapacity 49 days Baal 1 3 6 1 4 1 546 1 1 7 8 30 0 Mteger 60 18 11 06 2 00 08 Run Queue runQLen Gauge 100 49 days n ag o3 Length ay 1 3 6 1 4 1 546 1 1 7 6 4 0 18 11 36 wapCapacity swapCapacity 49 days ab tend tory 13 6 14 1546 1 1 7 8 30 0 Mteger 60 18 11 06 2 00 03 eS a SS EES Add History Entry Figure 55 Sample AdvantEDGE View History Control Table Configuring the History Control Table You can control which MIB objects the SystemEDGE agent stores in the History table by adding deleting or modifying entries in the History Control table
55. Manual for more information Included here are some sample MIB variables that match the sample entries in the Empire Enterprise MIB To use these examples you should specify the path to the getextension program and uncomment the following lines extension 1 OctetString ReadOnly sysedge contrib getextension bat extension 2 OctetString ReadOnly sysedge contrib getextension bat extension 3 OctetString ReadOnly sysedge contrib getextension bat extension 4 OctetString ReadOnly C sysedge bin getver exe f S6SystemRoot system32 sysedge dll1 extension 5 OctetString ReadWrite C sysedge bin bounce exe eHealth SystemEDGE User Guide SEO HE i EHHH EH EHAA o E E E E E H H E E HHHH H H H Sample sysedge cf Fie 121 extension 10 Integer ReadOnly C sysedge bin checkfile exe C root exe In Windows systems you can further extend the Empire Enterprise MIB by adding new variables from the NT Registry and Perfmon services These values are obtained directly from the system without the need for an external program See the SystemEDGE Agent User Manual for more information Included here are some sample MIB variables that user this facility ntregperf 1 OctetString Registry SYSTEM Current ControlSet Control CrashControLl D umpFile ntregperf 2 Gauge Performance Objects Threads 1 ntregperf 3 Counter Performance TCP Segments Sent sec 1 ntregperf 4 Integer Registry SYSTEM CurrentCo
56. Monitor Table Entries to the sysedge mon File 509 Table 90 Fields for NT Event Monitor Entries Page 2 of 2 ntEventMonTypeFilter Number that identifies the event type to match for this entry Types 1 through 5 are defined by Windows as follows e error 1 warning 2 information 3 success 4 failure 5 Type all 6 indicates that all event types should match ntEventMonSrcFilter Regular expression to apply to the Event Source when scanning the events for matches For more information about specifying regular expressions refer to the UNIX man page on egrep 1 ntEventMonDescFilter Regular expression to apply to the Event Description when scanning the events for matches For more information about specifying regular expressions refer to the UNIX man page on egrep 1 ntEventMonStatus SNMPv2 RowStatus one of the following e active 1 e notInService 2 e notReady 3 ntEventMonAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when a match is found and a trap is sent If the string is empty no action will be performed for this entry ntEventMonFlags Unsigned integer flags value indicating additional behavioral semantics this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field refer to Chapter 15 Configuring History Co
57. NT Event Monitor Table The following example lists the contents of the agent s NT Event Monitor table edgewatch 127 0 0 1 public ntevent list eHealth SystemEDGE User Guide 376 e Chapter 14 Configuring Windows Event Monitoring Adding an NT Event Monitor Entry The following example adds a new entry to an agent s NT Event Monitor table at table index 5 to search for login failures on a Windows system edgewatch 127 0 0 1 private ntevent add 5 0x0 Security Failure gt m Failed login attempt WARNING local bin mail2admin exe This example also instructs the agent to run the local bin mail2admin exe script when the agent finds a match Deleting an NT Event Monitor Entry The following example deletes an entry from an agent s NT Event Monitor table at table index 5 edgewatch 127 0 0 1 private ntevent delete 5 Disabling an NT Event Monitor Entry The following example disables the NT Event Monitor table entry at table index 5 by setting that entry s status to notInService 2 The entry will remain in the table but the agent will not scan the event log for matches unless the entry s status is returned to active 1 edgewatch 127 0 0 1 private ntevent setstatus 5 2 The value 2 corresponds to the Row Status textual convention value notInService 2 Removing NT Event Monitoring Entries eHealth SystemEDGE User Guide To stop the self monitoring of a particular Windows event log you must remove that entry from
58. Od 07030 activet1 gt fvar log daemon log su fail 0 Od 0 0 0 activet1 gt tmp testprag log start 2 nd 1729253 program starting activet1 gt tmp testprog log stop al 5d 1729 53 program stopping active 1 a il e z OK ert Fae Figure 49 Systems Management MIB Log Monitor Table Sample Entries eHealth SystemEDGE User Guide Log Monitor Table 335 Columns of the Log Monitor Table Table 50 describes the columns of the Log Monitor Table For more information about the Log Monitor Table and its fields refer to the Systems Management MIB empire asn1 in the doc subdirectory of the SystemEDGE agent distribution Table 50 Columns of the Log Monitor Table Page 1 of 2 sn nane Pe Sn LogMonitorIndex Read Only Row of the table LogMonitorLogFile Read Write Complete path and file name of the log file to be monitored Note The file you monitor must be an ASCII based text file SystemEDGE does not support monitoring of other character sets such as Unicode You can determine a file s encoding by opening it in a text editor and selecting Save As The encoding is listed in the Save as type field LogMonitorRegularExpression Read Write Regular expression to search for when scanning the log file for matches For information about the rules for specifying regular expressions refer to the UNIX man page on egrep 1 LogMonitorNumberTraps Read Only Number of times that a trap was sent because a string matching the re
59. On Windows systems walktree was unable to initialize the WinSock library and could not communicate with the targeted agent The requested action therefore was not performed xtrapmon Error Messages eHealth SystemEDGE User Guide This section describes error messages that may be generated by the xtrapmon utility Parse error for trap from xtrapmon encountered an error parsing a trap from an SNMP agent Received PDU of type X instead of Trap xtrapmon received an SNMP PDU that was not a trap Normally xtrapmon receives only Trap PDUs xtrapmon failed to get trap socket xtrapmon failed to bind to port UDP 162 the SNMP trap port This problem usually occurs if another process is already bound to that port You can solve this problem by terminating the other trap receiving process xtrapmon snmprecv failed xtrapmon encountered an error in the library routine that receives and parses SNMP PDUs Therefore it did not return a Trap PDU Command line Utility Error Messages 487 xtrapmon WSAStartup failed On Windows systems xtrapmon was unable to initialize the WinSock library and could therefore not bind to the SNMP trap port It will therefore not receive any traps eHealth SystemEDGE User Guide Using the syslog Facility The SystemEDGE agent uses the UNIX syslog facility to log informational messages and error conditions that it may encounter during its operation For more information about the syslog f
60. On startup the agent configures these values and verifies whether the program or command associated with the variable is executable Within the configuration file the keyword extension defines an extension variable The next section describes how to use this keyword Using the extension Keyword You can use the extension keyword to add entries in the extension group as follows extension LeafNumber Type Access Command eHealth SystemEDGE User Guide 394 e Chapter 16 Adding Custom MIB Objects Table 75 describes the parameters of the extension command Table 75 Parameters for the extension Command LeafNumber Extension variable number in the range of 1 through 2 that is being defined by this entry Type SNMP type for this entry The supported types are as follows Integer Counter Gauge Octetstring TimeTicks Objectid IPAddress One of the following Read Only Read Write Command Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when this variable is accessed through either a Get GetNext or Set request If the command file is not currently accessible the configuration of this variable will fail Additional Parameters In addition to the parameters that you specify in the configuration file as part of the extension command the SystemEDGE agent passes some additional parameters to help you decide how to trea
61. Process Group Monitor Table 327 Configuring the Process Group Monitor Table 328 Dynamic Configuration During Operation 328 Initial Configuration During Startup 329 Monitoring a Process Group 1 2 2 e eee eee eee ees 329 Process Group Monitoring Examples 4 330 Removing Process Group Monitoring Entries 331 Removing Entries from the sysedge cf File 331 Removing Entries with the edgemon Utility 332 Removing Entries Manually 20002 e ee 332 Configuring Log File Monitoring 333 Monitoring Log FileS 02s2cceceseouesaeestesny aa deeeases 333 Loe Montor RADIC avtaegaeancnosnmeeases eeensesettatens 334 Columns of the Log Monitor Table 335 Optimizing Row Creation 2 0 eee eee ee eee 337 Log Monitor Table Flags snnnnununennnunnren reen 337 Log Monitor Table Actions 0 0 cece e eee e eee nee 340 Viewing the Log Monitor Table with AdvantEDGE View 342 Configuring the Log Monitor Table 0 343 Initial Configuration During Start Up 343 watch logfile Examples 0 0 cece cece eens 344 Dynamic Configuration During Operation 345 Using the edgewatch Utility to Monitor Log Files 345 edgewatch Commands for Log File Monitoring 346 Sample Uses of the edgewatch Utility 348 Removi
62. Process Monitor Table The pmonIndex column of the Process Monitor table acts as a row index to distinguish rows in the table Rows 1 through 10 are reserved for internal use by the SystemEDGE agent Users can configure rows in the range of 11 to MAXINT For more information about reserving blocks of rows refer to Reserving Blocks of Rows on page 258 Configuring the Process Monitor Table You can control the processes and process attributes that the SystemEDGE agent monitors by adding deleting or modifying the entries in the Process Monitor table eHealth SystemEDGE User Guide Configuring the Process Monitor Table 299 You can configure the Process Monitor table in the following ways Dynamically Use SNMP commands from a management system such as AdvantEDGE View to modify the table For more information refer to the next section Dynamic Configuration During Operation At start up initialization Specify the process attributes to monitor through the agent s configuration file sysedge cf For more information refer to Initial Configuration During Startup on page 300 You can also dynamically add delete or modify Process Monitor Table entries through the edgewatch utility For more information refer to Using the edgewatch Utility to Monitor Processes on page 310 Dynamic Configuration During Operation The SystemEDGE agent uses the SNMPv2 SMI Row Status textual convention for creating
63. SNMP types refer to Chapter 16 Adding Custom MIB Objects lock of mnttab lock failed The SystemEDGE agent failed to lock the UNIX mounted device file Consequently information about mounted file systems may not be supported eHealth SystemEDGE User Guide SystemEDGE Agent Error Messages 457 license file etc sysedge lic not found The SystemEDGE agent could not find the default UNIX license file etc sysedge lic Without a proper license the SystemEDGE agent will not continue to operate license file not found The SystemEDGE agent could not find a license file that was provided on the command line Without a proper license the SystemEDGE agent will not continue to operate log file is not regular The SystemEDGE agent was instructed either through configuration file statements or remotely through SNMP to monitor a log file that is not a regular ASCII file Consequently the SystemEDGE agent will not monitor the log file for the corresponding regular expression log filename too long A log file name that was specified in the SystemEDGE agent configuration file exceeds the maximum file name length of 256 characters Consequently the SystemEDGE agent will not monitor the log file for the corresponding regular expression logmon entry X re initialized The Log Monitor entry x was automatically reinitialized by the SystemEDGE agent logmon regcomp failed X A invalid regular expression was configured for
64. SystemEDGE agent overwrites this file every time the stored tables Monitor Process Monitor Process Group Monitor Log Monitor NT Event Monitor or History Control are modified Before you edit this file copy it from the SystemEDGE agent distribution to the etc directory or the system root directory as follows To copy sysedge mon to the etc directory on a UNIX system enter the following command cp config sysedge mon etc To copy sysedge mon to the system root directory on a Windows system enter the following command at the command prompt copy config sysedge mon SystemRoot system32 This file consists of comments and table entries Lines that are empty or begin with a pound sign are treated as comments and are ignored Comments conclude at the end of the each line Adding Monitor Table Entries to the sysedge mon File Monitor table entries begin with the keyword monitor They are delineated by open and closed brackets and include ten fields Table 86 describes the fields of the Monitor table entries for the sysedge mon file eHealth SystemEDGE User Guide Adding Monitor Table Entries to the sysedge mon File 495 Table 86 Fields for Monitor Table Entries in sysedge mon Page 1 of 3 Beginning of the entry is marked by an open bracket monIndex Integer 1 to MAXINT that indicates the row index for this entry Rows 1 through 10 are reserved for the agent s internal use the index for additional rows
65. Systems Management MIB enables you to configure the SystemEDGE agent dynamically to monitor groups of processes that are running on the underlying system You select the process group regular expression and interval and the agent uses that information to monitor those process groups You can configure the SystemEDGE agent to monitor process groups to determine what processes exist in each group and whether the group membership changes If components of an application start or fail or if members leave a group or are added to a group the SystemEDGE agent can automatically notify the NMS 319 320 Chapter 12 Configuring Process Group Monitoring The Process Group Monitor Table The Process Group Monitor table provides information about a group of processes that the agent is currently monitoring You can add entries to this table modify existing entries or remove entries from the table The SystemEDGE agent sends a processGroupChange trap to indicate when a process group changes and you can configure the agent to perform actions whenever a group changes Columns of the Process Group Monitor Table Table 46 describes the columns that make up the Process Group Monitor table For a complete description of the Process Group Monitor table and its fields refer to the Systems Management MIB specification empire asn1 in the doc subdirectory of the SystemEDGE agent distribution Note SystemEDGE maintains a history of
66. Technical Support by sending e mail to support concord ca com unknown system type eHealth SystemEDGE User Guide This message indicates that the SystemEDGE agent could not determine if the underlying Windows system is configured as a Windows Server or a Windows Workstation Report this message to Technical Support by sending an e mail to support concord ca com SystemEDGE Agent Error Messages 4 71 username X not found all subprograms will be disabled This message indicates that the username that is specified in the sysedge cf configuration file for subprogram execution does not exist Consequently all subprogram execution by SystemEDGE agent will be disabled Using config file This message indicates that the SystemEDGE agent for Windows is using the specified configuration file This message is informational only and does not indicate that an error has occurred Using monitor file This message indicates that the SystemEDGE agent for Windows is using the specified monitor configuration file This message is informational only and does not indicate that an error has occurred using old config file This message indicates that the SystemEDGE agent is using a configuration file from a release earlier than Release 3 0 This message is informational in nature using old monitor file X updates will be placed This message indicates that the SystemEDGE agent is reading a monitor configuration file x for a release that
67. User Guide 270 e Chapter 10 Configuring Threshold Monitoring Monitoring Number of Incoming Packets on the Interface The following example configures the SystemEDGE agent to monitor the rate at which packets are received by the first ethernet interface which is le0 for Sun systems monitor oid ifInUcastPkts 2 16 0x0 60 delta gt 1000 Monitor le0 Incoming Packets mi The values in this example are defined as follows ifInUcastPkts 2 is the OID that indicates the particular MIB object instance to sample e 16 indicates that the entry is index 16 in the Monitor Table e 60 indicates that the agent should calculate the rate every 60 seconds e delta tells the agent to measure the rate at which the number of incoming packets ifInUcastPkts is changing e 1000 specifies the value to use in the comparison If the change in rate is greater than gt 1000 the agent sends a trap e indicates that no action is specified Monitoring Number of Outgoing Packets on the Interface The following example configures the SystemEDGE agent to monitor the rate at which packets are transmitted by the first ethernet interface which is le0 for Sun systems monitor oid ifOutUcastPkts 2 17 0x0 60 delta gt 1000 Monitor leO Outgoing Packets tI The values in this example are defined as follows e ifOutUcastPkts 2 is the OID that indicates the particular MIB object instance to sample 17 indicates that the entr
68. account username and password Username Password InstallShield Back Cancel 22 Enter your user name and password in the Username and Password fields and then click Next The Host to License dialog box appears eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 71 InstallShield Wizard Host to License Please indicate the hostname or IF address for the system which you are licensing Hast 172 16 100 37 InstallShield Back Cancel 23 Enter the hostname or IP address of the system you want to license in the Host Field The Licensing Information dialog box appears NOTE The IP address supplied for licensing must permit SNMP SET operations If you have an ACL the IP address must match one of the hosts in the ACL or licensing will fail If a failure occurs the agent can be licensed separately from the installation process eHealth SystemEDGE User Guide 72 e Chapter 2 Installing the SystemEDGE Agent InstallShield Wizard Licensing Information Please enter the following information Hame InstallShield Back Cancel 24 Enter your name in the Name field and then click Next 25 After entering the name and clicking next the following dialog box will appear Q The following licensing data will be sent to license concord com in addition to the information just collected SystemEDGE MySystemName NT x86 5 0 110601bd08930452 4 2 Patchlevel 1
69. adm messages su fail su attempt WARNING watch logfile 2 0x8 var adm messages sysedge fail sysedge fail NOTICE watch logfile 3 0x8 usr adm sulog su su attempt WARNING watch logfile 4 0x8 var log daemon log su fail su attempt WARNING watch logfile 10 0x8 C eHealth log pollerStatus messages stats log error eH poller error You can add process monitoring entries to have the agent automatically monitor a running process This creates an entry in the Empire Process Monitor Table Usage watch process procAlive regexp index flags interval descr action watch process attribute regexp index flags interval stype oper value aescr Taction eHealth SystemEDGE User Guide 124 e Examples watch process procAlive watch process procRSSs Netscape Size watch process procAlive watch process procAlive watch process procAlive watch process procAlive watch process procAlive watch process procAlive watch process procAlive watch process procAlive watch process procAlive Service watch process procAlive watch process procAlive Connection watch process procAlive watch process procAlive watch process procAlive Service watch process procAlive watch process procAlive watch process procAlive watch process procAlive Communication Server watch process procAlive watch process procAlive watch process procAlive w
70. and read write communities You can modify those communities or define additional communities manually in the sysedge cf file The configuration file defines access communities using the following format community community name permissions access list The variables are defined as follows e community name Is any octet string e permissions is either read only or read write e access list is a space separated list of IP addresses in dotted decimal notation that defines the systems that have access using the given community string Access lists are not totally secure because systems can still spoof IP addresses Access lists do however provide the ability to restrict legitimate use Configuring Access Communities 129 In the following example SystemEDGE allows read write access using the community string private only to systems with one of the following IP addresses 127 0 0 1 45 0 4 10 45 0 8 12 or 198 130 5 7 SystemEDGE treats any other system that attempts to use private as an authentication failure community private read write 127 0 0 1 45 0 4 10 45 0 8 12 198 130 5 7 NOTE The community string of private is used here only as an example Do not use this value for a read write community string Instead use something like eLtHakSoR97 Use the examples in this chapter as guidelines for editing the sysedge cf file to define your own access communities Specifying the Access List If the access list is empty System
71. and services The SystemEDGE agent can monitor many attributes of a process including whether it is running its size CPU and memory and usage and the number of disk and network I O operations Monitoring Processes and Windows Services For information about monitoring process groups refer to Chapter 12 Configuring Process Group Monitoring The flexible Process Monitor table of the Systems Management MIB enables you to configure the agent dynamically to monitor specific attributes of important processes services and applications that are running on the underlying system You specify the process attribute threshold value and interval that you want to monitor If a process attribute crosses the threshold you specified the agent sends an SNMP trap to the management systems you have configured The agent can also invoke an action command on the managed system to immediately correct the problem Monitoring Windows Services On UNIX systems services or daemons are processes which can be monitored just like any other process On Windows systems however services are special kinds of processes that are started and stopped using a graphical interface for example through the Services Control Panel Windows services run 281 262 e Chapter 11 Configuring Process and Service Monitoring within processes but the mapping between them is not always one to one For example multiple Windows services may run within a single pro
72. are passed on the command line after those that you specify The default parameters are the same as the parameters provided in the SNMP traps sent for the NT Event Monitor table Table 66 describes the default parameters for NT Event Monitor table actions Table 66 Default Parameters for NT Event Monitor Table Actions Page 1 of 2 trapType Type of trap that is being sent such as ntEventMonMatchEvent or ntEventMonNotReadyEvent ntEventMonLog Event log that the agent is monitoring eHealth SystemEDGE User Guide NT Event Monitor Table Actions 367 Table 66 Default Parameters for NT Event Monitor Table Actions Page 2 of 2 ntEventMonTypeLastMatch Type of event that generated this trap ntEventMonTime Time that this event was generated ntEventMonSrcLastMatch Source of the event that generated this trap ntEventMonDescLastMatch Description of the event that generated this trap ntEventMonDescr Description of this entry ntEventMonIndex Index for this entry ntEventMonFlags Flags field in hexadecimal notation for example 0x0000 for this table entry For more information about traps sent by the SystemEDGE agent refer to Chapter 8 Private Enterprise Traps NOTE The SystemEDGE agent logs action command invocation errors to the sysedge log file For information about starting the agent with its debugging options turned on refer to Configuring Support for Agent Debugging on page 135
73. asec 466 stat of extension command file X failed 466 stat of logmon action X failed 0 0 eee eee ee eee 466 stat of monfilesys action X failed 00 000 466 stat of monprocess action X failed 0000 eee 467 stat of nteventmon action X failed 008 467 sysedge using port X config file Y 0 008 467 system Call ret error X s insdewareraiwes ciacdtaoeneed sd 467 This agent binary is compiled for X not Y 467 timeGetDevCaps failed exiting 0 eee eee 468 timeKillEvent failed 25 o2 54 02a seebadeescutadtasageeeas 468 trap ipaddress hostname X invalid 0006 468 turning off process table support 0 cee ee 468 turning off sets to Empire process table 468 two processes with PID X cece eee eee eens 469 two software packages with same index 469 eHealth SystemEDGE User Guide 20 e Table of Contents unable to open monitor file 0 0 ee cee 469 unable to process acl for community X 469 nknown HP CPU yp scstecteseereras cneseaueyeases 470 unknown NT event log name eee eee eee 470 unknown NT event type 0 cece cece eee ences 470 unknown service start type 0 cece cece eee eee eee 470 unknown system type eee cece cece eee eee e ees 470 username X not found all subprograms will be disabled 471 Using config file 0
74. availability unusual workload and latency Fault Manager is an enhancement to Live Exceptions that enables eHealth to receive SNMP trap messages from devices and systems Fault Manager interprets and processes trap information reduces the noise of duplicate and repeated messages and alerts you to the problems and conditions that interest you When the eHealth system receives a trap it processes the trap based on Live Exceptions rules and profiles that you configure Thus you can configure Fault Manager to raise an alarm for the associated element or to ignore various trap messages NOTE You can edit the sysedge cf file to configure the SystemEDGE agent to feed specific traps to Fault Manager For more information refer to Configuring Trap Communities on page 130 Guidelines for Using the SystemEDGE Agent 43 Figure 3 shows how Fault Manager collects data from SNMP trap sources such as the SystemEDGE agent and sends it to a variety of displays Live Status Fault Manager Fa p ee LIVE i Exceptions see Mm Live Health K u Live Trend Motif eHealth y Applications Systems f Networks Reports Figure 3 eHealth and Live Health Fault Manager Guidelines for Using the SystemEDGE Agent You can gain the most value from the SystemEDGE agent by setting up effective management policies for your systems networks and applications In particular follow these guidelines e Use the Syste
75. bits to alter these defaults The SystemEDGE agent interprets all flags in hexadecimal base 16 notation Figure 50 shows the flags field logMonitorFlags eHealth SystemEDGE User Guide 338 e Chapter 13 Configuring Log File Monitoring Ws bits network byte order W__ 12 bits for flag value 12 bits table specitic tags amp bits global dags OeCI HHH gt Of fH OOD FRE gt KIQ EE HAF ChGHRARAROO gt CoghhAet Figure 50 Log Monitor Table Flags The flags consist of three fields Field 1 Common table flags defined for the self monitoring tables of the Systems Management MIB This portion is the low order 8 bits of the flags Field 2 Table specific flags that are defined separately for each of the self monitoring tables This field defines the next 12 low order bits after the common table flags Figure 51 on page 340 describes how these 12 bits are defined for the Log Monitor table Field 3 Reserved 12 high order bits for an integer value for use in conjunction with table specific flags This field includes flags that are specific to the Log Monitor table NOTE The following sections define each flag bit You can combine flag values through a logical OR operation eHealth SystemEDGE User Guide Log Monitor Table Flags 339 Table 52 describes the flags of the Log Monitor table Table 52 Log Monitor Table Flags Page 1 of 2 Li NO a 0x00000001 Do not execute actions for this entry
76. by enabling them to control all workstations on their networks from a single central location The agent extends management beyond the network boundary and into attached systems to automate systems management tasks and inventory tracking functionality that is necessary for increasing productivity and system stability while helping to reduce rising system support costs You can use the SystemEDGE agent to distribute management tasks to the host systems Introducing eHealth SystemEDGE The SystemEDGE agent provides powerful system management through the industry standard SNMP It enables remote management systems to access important information about the system s configuration status performance users processes file systems and much more In addition the agent includes intelligent self monitoring capabilities that enable reporting and managing of exceptions and that eliminate the need for excessive polling Microsoft Data Center Certification The SystemEDGE agent does not touch the system kernel whether it runs on a Unix Linux or Windows system So SystemEDGE does not require Data Center Certification 27 28 e Chapter 1 Introduction Using eHealth SystemEDGE To use the SystemEDGE agent you must first install it on every workstation or server that you want to monitor You can then configure it to monitor that system for variables that you specify The SystemEDGE agent interoperates with SNMP network managem
77. by entering the following snmpget public 127 0 0 1 1 3 6 1 4 1 546 14 1 0 debugSetString For more information refer to the debugext sh example that exists on the SystemEDGE Contributed Information page at www concord com sysedge contrib Using Extension Variables with Your Management Software All methods for incorporating extension variables into your management system software for example Cabletron Spectrum HP OpenView Sun Enterprise Manager and so on require you to edit and import MIB specification files This guide does not discuss details of importing MIB specification files into management system software but it does describe the two overall strategies exist for incorporating extension variables e Edit empire asn1 to include the extension variables that are defined for your site e Edit a separate MIB file to include the extension variables that are defined for your site eHealth SystemEDGE User Guide 400 e Chapter 16 Adding Custom MIB Objects Editing empire asn1 for Extension Variables Follow these steps to add your own extension variables to the Systems Management MIB empire asn1 1 Create and debug the relevant extension scripts and then configure them in the agent s configuration file sysedge cf to include them 2 Edit empire asn1 to include new extension MIB variables that exist under the extensionGroup 3 Perform a test compile of empire asn1 to ensure there are no syntax errors This
78. can use the diagsysedge exe program to verify that the agent is running and to obtain information about the agent that you can use for troubleshooting NOTE The examples in this section assume that the agent has a read community of public and is on port 161 or 1691 Determining Whether the Agent Is Running You can run diagsysedge exe with the b option to determine whether the agent is running To determine whether the agent is running 1 Change to the sysedge bin directory 423 424 e Chapter 19 Troubleshooting and Usage Suggestions 2 Enter the following diagsysedge exe b The command provides output similar to the following diagsysedge exe b Copyright C 2003 Concord Communications Inc All rights reserved http www concord com http www concord com sysedge diagsysedge V1 01 0 LINUX egyptian 2 2 14 5 0 Red Hat Linux release 6 2 Zoot 1 Tue Mar 7 21 07 39 EST 2000 Concord Communications Inc SystemEDGE Agent Version 4 1 Patchlevel 4 If the agent is not running you receive an error message that the SNMP operation failed Attempt to start the agent again using the instructions in Chapter 5 Starting the SystemEDGE Agent for your operating system Obtaining a Report for Troubleshooting If you are encountering problems with your SystemEDGE agent Technical Support may ask you to run diagsysedge exe to generate a report that they can use for troubleshooting To generate a report
79. cheryl ttypE fs Od 18 26 25 10 0 T F rdk ttup fs d 18118 5356 ottomanzo 0 4 E cheryl ttyp Od r245 0 0 2 Figure 8 Systems Management MIB Sample Who Table Remote Command Execution Use the Remote Shell Group to execute shell scripts and programs on the remote host system MIB variables in the Remote Shell group let you specify the command its arguments and the name of a file where the output will be written You can specify the command and arguments by setting the remoteShell MIB variable specify the output file by setting shellOutput When you perform an SNMP Set on the shellCmd MIB variable the agent fork execs the specified command with standard output stdout and standard error stderr redirected to the file that is named by the shellOutput MIB variable When the command finishes executing the agent puts the command s exit status in shellExitStat eHealth SystemEDGE User Guide 178 e Chapter 7 Systems Management MIB Executing a Remote Command When you are performing SNMP Enter the following at a command prompt to execute a remote Set operations use a community command name that allows you read write access SET shellOutput 0 output filename SET shellCmd 0 command NOTE Depending on your local security policies you may want to disable support for this table For more information about disabling this support refer to Configuring Support for Remote Shell Capability on page 133
80. commands 177 extending Systems Management MIB adding custom MIB objects 391 Extension group 212 ntRegPerf group 403 extension directive parameters 394 specifying additional parameters 394 syntax 393 Extension group examples pinging remote system 397 returning DNS domain name 396 returning NIS domain name 396 features 392 sample MIB branch 392 Systems Management MIB 212 391 writing extension scripts 397 extension scripts writing 397 extension variables Index 533 configuring 393 editing empire asn1 400 editing separate MIB specification 400 examples 392 pinging remote system 397 returning DNS domain name 396 returning NIS domain name 396 using with management software 399 F Fault Manager 42 file system space monitoring 168 flags Log Monitor table 337 Monitor table 252 NT Event Monitor table 363 Process Group Monitor table 325 Process Monitor table 289 floppy devices configuring status checking 135 G getextension sh 96 getver exe 93 Group table 173 H history collection collecting disk transfer history 512 History Control table 206 History table 205 introduction 33 overview 379 History Control table adding entries 511 AdvantEDGE View display 384 eHealth SystemEDGE User Guide e ndex columns 381 configuring 384 configuring support 142 configuring with emphistory directive platform support 23 removing SystemEDGE 101 SNMP agent 162 system requirements 75 385 description 381
81. config subdirectories to enable you to compare the new files with the existing files Reviewing the Configuration Files 87 Table 6 lists the chapters in which you can find more information about these configuration files Table 6 Configuration Files Page 1 of 2 Configuration File Chapter Containing More Information sysedge mon e Chapter 10 Configuring Threshold Monitoring Chapter 11 Configuring Process and Service Monitoring Chapter 12 Configuring Process Group Monitoring Chapter 13 Configuring Log File Monitoring Chapter 14 Configuring Windows Event Monitoring Chapter 15 Configuring History c3 Collection e Appendix C sysedge lic Chapter 3 Licensing the SystemEDGE Agent eHealth SystemEDGE User Guide 88 e Chapter 2 Installing the SystemEDGE Agent Table 6 Configuration Files Page 2 of 2 Configuration File Chapter Containing More Information sysedge cf e Chapter 4 Configuring the SystemEDGE Agent Chapter 5 Starting the SystemEDGE Agent Chapter 10 Configuring Threshold Monitoring Chapter 11 Configuring Process and Service Monitoring Chapter 12 Configuring Process Group Monitoring Chapter 13 Configuring Log File Monitoring Chapter 14 Configuring Windows Event Monitoring Chapter 15 Configuring History Collection Chapter 16 Adding Custom MIB Objects Chapter
82. configure the SystemEDGE agent for Windows to report additional registry parameters and performance data without using external programs or scripts This feature allows you to monitor the health of applications that make performance data available through the performance registry For more information refer to Chapter 17 Adding Windows Registry and Performance MIB Objects Using eHealth SystemEDGE 35 Specifying Corrective Actions The SystemEDGE agent can automatically respond to critical situations on a system by invoking actions which are specific commands or scripts that the agent can run automatically when configured to do so For example you can specify actions that enable the agent to restart a failed process send e mail to an administrator in the event of an unauthorized access to the system and so on You can also configure the SystemEDGE agent to perform corrective actions in response to traps For example you can configure the agent to run a script or program when a variable s value crosses a specified threshold or when the agent discovers specific matches on regular expressions in log files or Windows event logs When using actions you must specify the full path of the command along with any parameters The agent executes this command each time the conditions are met for the monitoring table entry If you do not specify an action the agent does not call a command or script in response to meeting the conditions
83. deleting and modifying rows in the table For more information about the Row Status textual convention refer to Appendix E You can modify the entries in the Process Monitor table by issuing SNMP Set request messages from your NMS to the SystemEDGE agent Each time the Process Monitor table is successfully modified the agent updates the etc sysedge mon file to record the changes This enables the agent to start up with the same Process Monitor table configuration that it had when it was stopped The sysedge mon file preserves changes that are made during the operation of the agent across agent and system restarts The agent overwrites the etc sysedge mon or SystemRoot system32 sysedge mon configuration files every time the Process Monitor table is modified NOTE Configuration file directives in sysedge cf take precedence over entries in sysedge mon For example if a Process Monitor table entry is contained in sysedge mon at index 10 and a configuration file directive for index 10 of the Process Monitor table is added to sysedge cf the entry that is defined in sysedge cf replaces the entry from sysedge mon eHealth SystemEDGE User Guide 300 e Chapter 11 Configuring Process and Service Monitoring The SystemEDGE agent software distribution includes a command line utility named edgewatch that takes a process name or PID as a command line argument and dynamically configures an entry in the Process Monitor table to monitor the
84. devices may cause the agent to block while the driver waits on status information You can use the no_probe_disks option to avoid potentially lengthy agent blocking To inhibit disk probing add the following line to sysedge cf no_probe_disks NOTE If this option is enabled the agent may be unable to provide disk statistics capacity information device descriptions and status information Configuring Support for Actions By default the SystemEDGE agent allows the execution of action commands in conjunction with the self monitoring tables The capability to execute action commands and scripts could be a potential security issue because the command and scripts could execute commands as the root or administrator users Depending on the local security policies in effect at your site you may wish to disable the agent s support for executing action commands For more information about actions refer to the following sections e Monitor Table Actions on page 255 e Process Monitor Table Actions on page 296 e Process Group Monitor Table Actions on page 326 e Log Monitor Table Actions on page 340 e NT Event Monitor Table Actions on page 366 To disable support for action execution add the following line to sysedge cf no actions eHealth SystemEDGE User Guide 138 e Chapter 4 Configuring the SystemEDGE Agent Disabling Support for Remote File System Checking UNIX Only By default the Sys
85. directive 329 utilities edgemon directory 90 using 274 edgemon exe 93 edgewatch directory 90 monitoring log files 345 monitoring processes 300 process monitoring 310 Index 545 edgewatch exe 93 emphistory 90 emphistory exe 93 licenseme 109 nteventmon error messages 479 restartsvc exe 93 sendtrap 90 sendtrap exe 92 snmpget error messages 483 sysvariable 91 sysvariable exe 93 walktree error messages 485 xtrapmon 91 xtrapmon exe 93 V verifying agent response to queries 426 starting at system initialization 426 status 426 that the agent is running 423 426 W walktree utility error messages 485 walktree exe 93 walktree txt UNIX 91 Windows 94 watch logfile directive examples 344 parameters 344 syntax 343 watch ntevent directive examples 371 parameters 370 syntax 370 eHealth SystemEDGE User Guide 046 e ndex watch procgroup directive X examples 330 xtrapmon utility parameters 329 description 91 syntax 329 error messages 486 Who Table xtrapmon l man page 91 configuring support 132 xtrapmon exe 93 information 176 xtrapmon txt 94 Windows adding registry variables 403 configuring registry and performance variables 408 event monitoring examples 371 introduction 33 log searching criteria 359 overview 357 Extensible agent 161 installing SystemEDGE 59 monitoring event logs 358 registry and performance 405 platform support 23 registry extensions 34 removing SystemEDGE 99 start
86. emphistory utility 387 examples I O Buffer Cache group Systems adding entries 389 Management MIB 184 collecting disk transfer history 512 deleting entries 389 listing entries 389 retrieving stored data samples 390 setting status of entries 389 overview 380 sample sysedge mon entries 512 Systems Management MIB 205 history sampling 379 History table columns 382 description 382 Systems Management MIB 205 identifying processes that consume the most CPU 33 implementing trap severity levels 436 indicating change in IP address 228 change in process group 229 Log Monitor entry is notReady 219 match in log file 218 match in Windows event log file 220 Monitor event 216 monRowsStatus is notReady 217 previous condition no longer exists 222 process attribute is no longer at threshold Host Resources MIB 226 Device group 236 process attributed has reached threshold Disk Storage table 239 225 File System table 240 process has restarted 224 introduction 29 overview 233 process has stopped running 223 status of NT Event Monitor entry is Partition table 239 l notReady 221 Processor table 238 installation Running Software group 241 directories 90 Storage group 236 files 90 System group 234 subdirectories Host System group 166 bin 90 92 hostmib asn1 97 config 94 HP UX doc 91 93 97 installing SystemEDGE 75 installing SystemEDGE eHealth SystemEDGE User Guide AIX 82 Digital UNIX 84 HP UX 75 Linux 80 Solaris 52 Tru64 84 W
87. entry LogFilename Complete path starting from root and file name of the log file to be monitored On Windows systems the log file name must start with a drive letter and absolute path Note The file you monitor must be an ASCII based text file SystemEDGE does not support monitoring of other character sets such as Unicode You can determine a file s encoding by opening it in a text editor and selecting Save As The encoding is listed in the Save as type field logMonRegExpr Specifies the regular expression to apply when scanning the log file for matches You must enclose values for logMonRegExpr in quotation marks For information about the rules for specifying regular expressions refer to the UNIX man page on egrep 1 logMonDescr Specifies the description for this entry It is a quoted string that is 0 to 28 characters in length and that normally contains a description of the file that is being monitored as well as a severity level for this event eHealth SystemEDGE User Guide 348 e Chapter 13 Configuring Log File Monitoring Table 56 edgewatch Command Arguments Page 2 of 2 logMonAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the agents finds a match for the regular expression and sends a trap If the string is empty or not specified the agent invokes no action for this entry Status Used
88. facility to log informational messages and error conditions that it may encounter during operation The syslog daemon typically logs these messages to the var adm messages text file depending on how the syslog daemon is configured on your system By eHealth SystemEDGE User Guide default the agent daemon uses syslog to log messages of priority levels informational through emergency If you are running the agent in debug mode through the d runtime command line option the agent also logs messages of priority level debug For information about configuring the syslog daemon on your system to log messages from daemon processes like sysedge to the var adm daemon log text file refer to Appendix B For more information about syslog refer to the following Man pages syslog 3 syslog conf 5 and syslogd 8 Logging Messages for Windows The SystemEDGE agent logs informational messages and error conditions that it may encounter during operation in the SystemRoot system32 sysedge log For information about possible problems that may arise during SystemEDGE agent operation refer to the sysedge log file UDP port 1691 is reserved for use by the SystemEDGE agent You can configure the agent to use that port instead of UDP 161 For more information about starting the SystemEDGE agent on an alternate port refer to Chapter 5 Starting the SystemEDGE Agent Using the SystemEDGE Agent with Other SNMP Agents This chapter d
89. failover event The Systems Management MIB provides basic information about the cluster with the following MIB objects e ntIsClustered e ntClusterName ntClusterMembers e ntClusterIsActive e ntClusterActiveNode For more information about these objects refer to the Systems Management MIB empire asn1 in the doc subdirectory of your SystemEDGE agent distribution You can view cluster data by running an AdvantEDGE View System Information query You can also use AdvantEDGE View to apply a custom SystemEDGE template for monitoring clusters to your systems For more information see the AdvantEDGE View Web Help NOTE While SystemEDGE can monitor the health of individual servers monitoring clustered environments requires additional intelligence to distinguish between a failure and a failover SystemEDGE cannot be used in these environments To monitor clustered environments use CA Unicenter NSM with its Advanced Systems Management option Using eHealth AdvantEDGE View 37 Using eHealth AdvantEDGE View If you are using the SystemEDGE agent with the eHealth AdvantEDGE View element manager you can run queries on the data collected by SystemEDGE agents through the AdvantEDGE View Web based graphical user interface AdvantEDGE View can also automate deployment licensing and configuration of your SystemEDGE agents You can access AdvantEDGE View from the Systems amp Apps tab of the eHealth Web interface Figure
90. following active notInService notReady createAndGo createAndWait Normally a row is either active or notInService These values are defined in the SNMPv2 SMI RowStatus textual convention For more information refer to Appendix E Process Attributes Table 38 describes the attributes that the SystemEDGE agent can monitor for a particular process or service The table also specifies the SNMP type for each attribute You can use the SNMP type to select the sample type and operator For example absoluteValue sampling is usually most appropriate for attributes of type integer or gauge while deltaValue sampling is usually most appropriate for attributes of type counter eHealth SystemEDGE User Guide 288 e Chapter 11 Configuring Process and Service Monitoring NOTE The agent s ability to monitor a particular process attribute is dependent on the underlying operating system s ability to track the associated parameter or metric Table 38 Process Attributes Attribute Percentage 0 to 100 of real memory used by this process Real memory resident set size of the process KB Priority nice value of this process eHealth SystemEDGE User Guide Process Monitor Table Flags 289 Optimizing Row Creation You can use the following MIB objects with the Process Monitor table to optimize row creation Table 39 Scalar Objects for Optimizing Row Creation pmonUnusedIndex Read Only You can use this variable to optimize
91. following are possible values e Application 1 e Security 2 e System 3 e Directory Service 4 e DNS Service 5 e File Replication Service 6 eHealth SystemEDGE User Guide NT Event Monitor Table 361 Table 63 Columns of the NT Event Monitor Table Page 2 of 3 GS pemes omen ntEventMonTime Read Only Time based on sysUpTime at which the event occurred ntEventMonMatches Read Only Number of times that a match occurred for this entry and the agent sent a trap ntEventMonTypeLastMatch Read Only Number that identifies the event type of the last event that matched the search criteria Types 1 through 5 are defined by Windows as the following e error 1 warning 2 information 3 success 4 failure 5 Type noMatch 6 indicates that there has not yet been a matching event for this monitoring entry ntEventMonTypeFilter Read Write Number that identifies the event type to match for this entry Types 1 through 5 are defined by Windows as the following e error 1 e warning 2 e information 3 e success 4 e failure 5 Type all 6 indicates that the agent should match all event types ntEventMonSrcLastMatch Read Only String that identifies the Event Source of the last event log entry that matched this monitor entry The Event Source is usually the name of the program that generated the event Each time a match occurs this variable is updated ntEventMonSrcFilter Read Write Regular expression to apply to the Ev
92. for some threshold When a Process Monitor table expression evaluates to True this Trap is sent The expression is pmonCurrVal pmonOperator pmonValue This Trap is sent if the value of pmonFlags does not preclude the sending of Traps eHealth SystemEDGE User Guide 226 e Chapter 8 Private Enterprise Traps processClear Trap The following code shows the format of a processClear trap which the SystemEDGE agent sends to indicate that a process attribute for which it previously sent a processThreshold event is no longer at the threshold level processClearEvent OBJECT IDENTIFIER traps 13 processClearTrap TRAP TYPE ENTERPRISE sysmgmt VARIABLES pmonIndex pmonDescr pmonAttribute pmonCurrVal pmonOperator pmonValue pmonFlags pmonRegExpr pmonCurrentPID DESCRIPTION This Trap is sent when using a Process Monitor Table entry to monitor some attribute e g memory usage process size of a process for some threshold When the threshold is crossed a processThreshold Trap is sent When the attribute threshold expression first transitions from True to False this Trap is sent igo eHealth SystemEDGE User Guide Format of Trap PDUs 227 license Trap The following code shows the format of a license trap which the SystemEDGE agent sends to indicate that it did not find a valid license for itself or one of the eHealth AIMs licenseEvent OBJECT IDENTIFIER traps 16 licenseTrap TRAP TYPE ENTERPRI
93. gt A noError Refer to Note 1 status column is active status column is notInService inconsistentValue inconsistentValue inconsistentValue inconsistentValue noError noError gt D gt D noError noError gt C or wrongValue noError noError gt gt noError noError gt C gt D 1 goto B or C depending on information available to the agent 2 if other variable bindings included in the same PDU provide values for all columns which are missing but required then return noError and goto D eHealth SystemEDGE User Guide 916 e Appendix D Textual Conventions for Row Status 3 if other variable bindings included in the same PDU provide values for all columns which are missing but required then return noError and goto C 4 at the discretion of the agent either noError or inconsistentValue may be returned NOTE Other processing of the set request may result in a response other than noError being returned e g wrongValue noCreation etc Conceptual Row Creation There are four potential interactions when creating a conceptual row selecting an instance identifier which is not in use creating the conceptual row initializing any objects for which the agent does not supply a default and making the conceptual row available for use by the managed device Interaction 1 Selecting an Instance ldentifier eHealth SystemEDGE User Guide The algorithm used to select an instance identif
94. hrliskStorageAccess hrliskStorageMedia hrliskStorageRemoveble hrliskStorageCapacity i readhritet1 Floppyliskt4 truei1 0 12 readhritec1 hardDiskts Falset 1027211 AB readhritec1 hardDiskts Falset 421641 l Ok est Pae Figure 25 Sample Host Resources Disk Storage Table Partition Table The hrPartitionTable shows the partitions that have been configured for the disk storage devices For each partition the table lists the following e Textual description of the partition e Partition ID e Size of the partition in KB Index of the file system mounted on that partition eHealth SystemEDGE User Guide 240 e Chapter 9 Host Resources MIB Figure 26 shows a sample hrPartitionTable for a Sun SPARC IPX system e SNMP Table Display Table hrPartitionTable Instance 12 1 12 2 Tz ify ilegal 13 2 teh set 13 8 Path 1 3 6 1 2 1 25 3 7 1 Rows 9 Columns35 hrPartitionIndex hrPartitionLabel hrPartitionID hrPartitionSize hrPartitionFSIndex il Partition sdla fdev sdila 28905 0 2 Partition sdib fdev sdib 58515 0 3 Partition sdic fdev sdic 1023660 4 7 Partition sd1g fdev sdlg 936240 0 1 Partition sd0a fdev sd0a 16560 1 2 Partition sd0b fdev sd0b 65520 0 3 Partition sd0c fdev sd0c 414360 0 fi Partition sd0g fdev sd0g 178200 2 8 Partition sd0h fdev sd0h 154080 3 ox esta Figure 26 Sample Host Resources Partition Table File System Table The hrFSTable provides information about the host
95. in meaning to the SNMPv2 SMI RowStatus textual convention For more information refer to Appendix E Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the expression evaluates to true and a trap is sent If the string is empty no action will be performed for this entry eHealth SystemEDGE User Guide Sample Monitor Table Entries in sysedge mon 497 Table 86 Fields for Monitor Table Entries in sysedge mon Page 3 of 3 monFlags Unsigned integer flags value that indicates additional behavioral semantics that this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field refer to Chapter 10 Configuring Threshold Monitoring End of the entry is marked by a closed bracket Sample Monitor Table Entries in sysedge mon This section includes examples for adding entries to the Monitor table through the sysedge mon file Monitoring 1 Minute Load Average The following entry in the sysedge mon file instructs the SystemEDGE agent to monitor the 1 minute load average every 60 seconds If the sampled value is greater than 300 3 00 in this example because SNMP does not support real numbers the agent sends an SNMP trap message monentry 11 Monitor 1 minute load average 60 absoluteValue Oh 62 170 PE Te Cie cs ekg a o a
96. in seconds The interval must be a multiple of 30 seconds Choose the interval carefully For example do not set the agent to sample so frequently that an operator does not have time to act on the monitored condition if an exception occurs eHealth SystemEDGE User Guide 302 e Chapter 11 Configuring Process and Service Monitoring Alternatively you could use a 7 Write a configuration directive to define the process you management station supporting have selected and add it to the sysedge cf file the RowStatus operation to add the row via SNMP Refer to 8 Start the SystemEDGE agent Dynamic Configuration During NOTE Operation on page 299 T E pas If you are monitoring the procAlive process attribute the SystemEDGE agent will automatically construct the appropriate Boolean expression Monitoring a Process to Make Sure It Is Running You can use the procAlive process attribute to ensure that a process is up and running When it is not running the SystemEDGE agent sends a processStop trap and invokes an action When the process is restarted the agent sends a processStart trap Using the watch process procAlive Directive You can use the watch process procAlive directive to add entries to the Process Monitor table as follows watch process procAlive procname index flags interv description action eHealth SystemEDGE User Guide Configuring the Process Monitor Table 303 Table 42 describes the paramet
97. information about specifying regular expressions refer to the UNIX man page on egrep 1 eHealth SystemEDGE User Guide Configuring the NT Event Monitor Table 371 Table 67 Parameters for the watch ntevent Directive Page 2 of 2 intEventMonDescFilt Regular expression to apply when scanning the Event Description attribute for each event in the log You must enclose this value in single quotation marks For more information about specifying regular expressions refer to the UNIX man page on egrep 1 ntEventMonDescr Description for this entry This value is a quoted string that is 0 to 128 characters in length and that normally contains a description of the file that is being monitored as well as a severity level for this event intEventMonAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the entry is matched and the agent sends a trap If the string is empty or not specified the agent invokes no action for this entry watch ntevent Directive Examples This section includes examples for using the watch ntevent directive Searching the Application Log for Web Server Messages The following example adds a new entry to the agent s NT Event Monitor table at table index 1 to search the Application log for messages from the http Web server application watch ntevent 1 0x00 Application All http Web S
98. information about users who are currently logged into a system For more information about this table refer to Chapter 7 Systems Management MIB Because the disclosure of this type of information could pose a potential security risk you might want to disable the agent s support for this information To disable support for the Who Table uncomment the following line in sysedge cf by removing the pound sign character from the beginning of the following line no who _table Configuring Support for User and Group Information 133 Configuring Support for User and Group Information By default the SystemEDGE agent supports the User table and the Group table which provide information about the user accounts and user groups that have been configured for the system The type of information in these tables is similar to the information that exists in the etc passwd and etc group directories For more information refer to Chapter 7 Systems Management MIB You might want to disable support for User and Group information in the following cases e Your organization considers the disclosure of user and group information to be a potential security issue e You have a distributed system with large numbers of users and or groups Because the agent periodically caches this information internally storing user and group information could consume a significant amount of resources To disable support for the User and Grou
99. log file monitoring either remotely through SNMP or through logmon configuration file statements The agent will not add this Log Monitor table entry but it will continue to monitor other log files for their corresponding regular expressions eHealth SystemEDGE User Guide 458 Appendix A Error Messages logmon trap entry not ready Index X The SystemEDGE agent has sent a Log Monitor trap message that indicates that entry x is notReady The agent will no longer perform log monitoring on behalf of Log Monitor table entry x but will continue to perform log monitoring on all other entries A Log Monitor table entry can become notReady when an error occurs while reading its log file logmon trap Index X The SystemEDGE agent has sent a Log Monitor trap message that indicates that it has detected a log file match for entry x The agent will continue to monitor this log file and will send additional trap messages when it finds new matches logmonitor action execution failed The SystemEDGE agent failed to execute a Log Monitor action command The agent will continue to monitor log files and will attempt to perform action commands when it finds matches malloc of trap contents failed The SystemEDGE agent failed to send a trap message because it was unable to acquire the necessary memory This error is most likely caused by a lack of memory on the underlying system The SystemEDGE agent will continue to attempt to send trap messages
100. monitoring 1 Select the SNMP object instance to be monitored This object instance must be supported by the SystemEDGE agent and must be implemented on the platform on which the agent is running For more information about object support refer to the MIB specifications and the eHealth SystemEDGE Release Notes for your platform You can choose objects from the supported MIB modules MIB II the Host Resources MIB or the Systems Management MIB On Windows systems you can select objects only from the Host Resources MIB and Systems Management MIB NOTE The object that you select must be of an integer based type such as integer gauge or counter You can use textual conventions or enumerated types if they result in an integer ASN 1 value 2 Assign the entry to a free row in the table by selecting the index number The index number must be greater than 10 and must not yet be in use in the sysedge mon file or by the agent eHealth SystemEDGE User Guide 260 e Chapter 10 Configuring Threshold Monitoring eHealth SystemEDGE User Guide Obtain the instance identifier for the object to be monitored Decide on the sample type If the object you have selected is a counter use deltaValue For most other integer values gauge enumerated integer integer and so on use absoluteValue Decide on the threshold and operator type against which the agent should compare the monitored variable s current value The compari
101. must fall in the range of 11 to MAXINT The index is particularly important because SNMP does not directly support creation and deletion of MIB objects instead it creates and deletes them as side effects of SNMP Set operations This limitation means that the person creating or modifying Monitor table entries through the monitor command or by editing sysedge mon must know the exact MIB table index to use for row creation monDescr Quoted string that is 0 to 128 characters in length and that normally contains a description of the object that is being monitored as well as a severity level for this event monInterval Integer value 30 to MAXINT that indicates how often in seconds the monitoring should be performed For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds monSampleType Either absoluteValue 1 or deltaValue 2 this value indicates whether this entry should sample the object s absolute value or whether the agent should take the difference between successive samples For example when monitoring counter variables use deltaValue because it describes the rate of change When monitoring gauges use absoluteValue because it describes the object s exact value monOID Complete object instance identifier that represents the value to be monitored Note that the instance portion of the object identifier for example 0 for scalars is also required The obj
102. need to configuration file directives exist to create all supported types of sysedge mon entries If Entries Are Not Being Added to sysedge mon If you are adding entries to sysedge mon through SNMP and find that the file is not being updated it is possible that the file was at some point changed to have read only permissions When sysedge mon is read only and you attempt to add new entries the following occurs sysedge mon regains read write permissions Two new files are created sysedge new contains the current content of sysedge mon plus any new entries you added from the time it was set to read only sysedge old contains the read only version of sysedge mon To resolve the problem and commit your changes to sysedge mon 1 Verify that the sysedge mon sysedge new and sysedge old files exist in the systemRoot system32 directory 2 Enter the following commands at the command line Attrib r sysedge Del systemRoot system32 sysedge old Del systemRoot system32 sysedge mon Move systemRoot system32 sysedge new sysedge mon eHealth SystemEDGE User Guide 436 e Chapter 19 Troubleshooting and Usage Suggestions Automatically Restarting Processes The SystemEDGE agent can perform actions when an entry in any of the agent s self monitoring tables evaluate to True You can use this capability to restart processes clean up file systems and so on To set the SystemEDGE agent to restart processes when they
103. organization 3 Copy the license into the sysedge lic file This file is located in the etc or SystemRoot system32 directory The license key is case sensitive Copy it exactly as it appears If possible use your system s copy and paste facility instead of typing it by hand If you are entering the license key manually be careful not to confuse characters such as the letters 1 and I and the number 1 or the letter O and the number 0 eHealth SystemEDGE User Guide 112 e Chapter 3 Licensing the SystemEDGE Agent 4 Save the sysedge lic file and then restart the SystemEDGE agent For UNIX systems restart the SystemEDGE agent by entering the following from the opt EMPsysedge directory when you are logged in as root bin sysedge b For Windows systems do one of the following Enter the following commands from the command line net stop sysedge net start sysedge Use the SystemEDGE Control Panel by selecting Start gt Settings Control Panel eHealth SystemEDGE On the SystemEDGE Control Panel click Stop Agent and then Start Agent The SystemEDGE agent is now licensed and ready to use Using the licenseutil pl Utility eHealth SystemEDGE User Guide The licenseutil Perl script parses a list of hostnames that you want to license collects license information from each system and then forwards the list of license keys to CA CA returns the list of licenses to the script and then the script populate
104. over 100 set 100 as the monValue against which the current value of the gauge is compared monLastCall Read Only Time based on sysUpTime at which the agent last sampled called the MIB variable it is monitoring 0 indicates that the MIB variable has not yet been sampled monNumTraps Read Only Number of traps that have been sent for this Monitor table entry This value provides a useful metric for determining how often the exception condition has occurred It also provides a means to detect a missed trap message eHealth SystemEDGE User Guide 250 e Chapter 10 Configuring Threshold Monitoring Table 30 Columns of the Monitor Table Page 4 of 4 Read Only monRowStatus o _ eHealth SystemEDGE User Guide Time based on sysUpTime at which the agent last sent a trap for this Monitor table entry 0 indicates that no traps have been sent One of the following e active e notInService notReady e createAndGo e createAndWait Normally a row is either active or notInService These values are identical in meaning to those defined by the SNMPv2 SMI RowStatus textual convention For more information refer to Appendix E Lowest minimum value that the agent has observed since it began polling the MIB variable Highest maximum value that the agent has observed since it began polling the MIB variable Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along
105. packets received by the particular application or process specify procMsgsSent pmonOperator Operator type A boolean operator used for evaluating the following expression currval operator value The operator can be one of the following nop no operation monitor the object s value but do not evaluate the Boolean expression et greater than It less than ge greater than or equal to le less than or equal to eq equal ne not equal pmonValue Integer value to which the current value of the monitored process attribute is compared during each monitoring cycle If the comparison evaluates to True where the operator type tells how to compare them the agent sends a trap For example if you want to be notified if the value of a gauge goes above 100 set 100 as the pmonValue against which the current value of the gauge is compared pmonFlags Integer flags value that indicates additional behavioral semantics this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field refer to Chapter 11 Configuring Process and Service Monitoring eHealth SystemEDGE User Guide Sample Process Monitor Entries in sysedge mon 501 Table 87 Fields for Process Monitor Table Entries Page 3 of 3 pmondAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameter
106. page 340 0x00000040 Do not send notReady traps for this entry eHealth SystemEDGE User Guide 340 e Chapter 13 Configuring Log File Monitoring Table 52 Log Monitor Table Flags Page 2 of 2 eg Description 0x00000100 Apply the logical NOT operator to the regular expression evaluation If the regular expression evaluation equals False this flag bit will be set to True and cause an event to occur If the regular expression evaluation equals True this flag bit will be set to False Use caution when utilizing this capability because False evaluations are converted to True and vice versa 0x00000200 Track the log file s size but do not parse through the file Ox 00000 Flag value 0x00100000 Oxfff00000 The Log Monitor table does not utilize this flag value field setting it has no effect on the Log Monitor table operation or on any of the supported flag bits Figure 51 shows flag bits that are specific to the Log Monitor Table Coed Oc Qed DAH Ord OHH Cec OQ SHE OL Cec DOA Oe H Apply logical NOT operator to regular expressions Do not parse through log files Figure 51 Log Monitor Table Specific Flag Bits Log Monitor Table Actions The SystemEDGE agent provides several default parameters to the action commands when they are invoked These parameters are in addition to any parameters you specify in the action string and are passed on the command line after those that you eHealth SystemEDGE User
107. place the index value of the last entry whose description matches in the pgmonMatchIndex MIB object pgmonMatchIndex Read Only You can use this MIB object with pgmonMatchDescr to match a particular entry description with its index number eHealth SystemEDGE User Guide Process Group Monitor Table Flags 9325 Process Group Monitor Table Flags The pgmonFlags column in the Process Group Monitor table is a 32 bit unsigned integer field that can specify additional behavioral semantics for the corresponding row By default the Process Group Monitor table row does the following e Attempts to reinitialize itself Sends SNMP traps e Logs syslog events Invokes actions if they are configured You can set different flag bits to alter these defaults The agent interprets all flags in hexadecimal base 16 notation Figure 47 shows the composition of the Process Group Monitor Table flags pgmonFlags field c 2 bits network byte order 12 bits for flag value 12 bits table specific flags 8 bits global flags Ox001 HHH gt OxffFHHHHH Ox000001 gt OxOOOfffH Ox HHHHEHOO gt Od fHHHHH TE Figure 47 Process Group Monitor Table Flags The flags value consists of three fields Field 1 Common table flags that are defined for the self monitoring tables of the Systems Management MIB This portion is the low order 8 bits of the flags field Field 2 Table specific flags that are d
108. process For instructions on how to use the edgewatch utility refer to Using the edgewatch Utility to Monitor Processes on page 310 Initial Configuration During Startup eHealth SystemEDGE User Guide On startup the agent reads the sysedge cf file You can use this file to specify which MIB variables you want SystemEDGE to monitor You can do so by adding watch process configuration file directives to the file This directive automatically configures the agent to monitor an attribute of a process that you specify You identify the process to be monitored through a regular expression that matches the process name and optionally for UNIX systems its arguments The agent automatically determines the PID for the specified process and then creates the appropriate entry in the agent s Process Monitor table You do not need to know the PID ahead of time or to use SNMP Set requests to add an entry to the Process Monitor table to use the watch process directive In addition if the process is not yet running the agent continues to try to match the regular expression to a process until it succeeds Then it initiates process monitoring Selecting Processes and Attributes for Monitoring This section describes how to specify MIB objects for process monitoring by adding them to the sysedge cf file As an alternative you can specify MIB objects through SNMP Set operations For more information about specifying objects through SNMP Set ope
109. processor vendor and the processor load The load is the average over the last minute of the percentage of time that the processor was not idle Tracking Processor Load By monitoring graphing the Processor Load average you can visually track the load that is being placed on the processor For example if the graph shows constant high levels indicating that the processor was heavily loaded you may decide that the host system is being overworked with too many users and processes so you could then take steps to limit the number of users or have some of the processes execute on another system A temporary spike in a Processor Load graph could be an indication that a processor intensive process is running To avoid problems that might result from such a heavy processor load you can reschedule that process to run at a time when processor load is less heavy Host Resources Device Group 239 Disk Storage Table The hrDiskStorageTable provides information about the host s disk storage devices For each disk storage device the columns of the table list the following e Storage media type for example hard disk or floppy disk e Whether the disk is removable e Storage capacity in KB e Whether the disk storage device allows read write or read only access Figure 25 shows an hrDiskStorageTable for a Sun SPARC IPX oe SNMP Table Display Table brliskStoragelable Fath 1 5 6 1 2 1 25 45 6 1 Rowet4 Columnetd Instance
110. provides sample values for each MIB object Table 15 Host System Information MIB Objects eHealth SystemEDGE User Guide Mounted Devices 167 Mounted Devices For information about the devices and file systems that are mounted on the host retrieve the Mounted Devices table Each row in the table represents a device that is currently mounted and contains columns that represent the following types of information e Device s mount point e Block size Total number of blocks Total number of free blocks Total number of files Total number of free files e Percent capacity percent used Figure 4 shows a sample Mounted Devices table eo SNMP Table Display Table devTable Path 1 3 6 1 4 1 546 1 1 1 7 1 Rows 10 Columns313 devDevice devMntPt devBsize devTblks devFblks fdev sd0a ie 1024 15487 3943 fdev sd0g fusr 1024 160423 25131 fdev sd0h fat22 1024 123911 91040 gomez pid14 gt fnet 512 0 0 morticiat ht1 ftmp_mnt net htl 1024 1010226 35797 morticiat usr local ftmp_mnt net usr local sun4d 4 1 3 1024 585500 124193 morticiat atl ftmp_mnt net at1 1024 821086 110823 morticiat usr spool mail ftmp_mnt net mail 1024 47098 37488 trantor datal other ftmp_mnt net other 1024 960042 198325 forget acl ftmp_mnt net act 1024 2056113 93624 L OK esta Figure 4 Systems Management MIB Mounted Devices Table eHealth SystemEDGE User Guide 168 e Chapter 7 Systems Management MIB Moni
111. status column has value notInService or it is not available for use by the managed device because the agent lacks sufficient information the status column has value notReady NOTE This textual convention may be used for a MIB table irrespective of whether the values of that table s conceptual rows are able to be modified while it is active or whether its conceptual rows must be taken out of service in order to be modified That is it is the responsibility of the DESCRIPTION clause of the status column to specify whether the status column must be notInService in order for the value of some other column of the same conceptual row to be modified ACTION set status column to createAndGo set status column to createAndWait set status column to active set status column to notInService set status column to destroy set any other column to some value RFC 1443 Textual Conventions for SNMPv2 e 515 To summarize the effect of having a conceptual row with a status column having a SYNTAX clause value of RowStatus consider the following state diagram status column does not exist noError gt D or inconsistentValue noError refer to Note 1 or wrongValue inconsistentValue inconsistentValue noError gt A Refer to Note 4 oA status column is notReady inconsistentValue inconsistentValue inconsistentValue Refer to Note 2 gt D inconsistentValue Refer to Note 3 gt C noError
112. sysedge mon file Monitoring the httpd Process Group The following entry in the sysedge mon file instructs the SystemEDGE agent to monitor the httpd process group every 60 seconds procgroupmon ik Monitor Web process group 60 httpd 0x0 W active eHealth SystemEDGE User Guide 906 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Adding Log Monitor Table Entries to the sysedge mon File Log Monitor table entries begin with the keyword logmon They are delineated by open and closed brackets and they include seven fields Table 89 describes the field for Log Monitor table entries in the sysedge mon file Table 89 Fields for Log Monitor Table Entries Page 1 of 2 logmon Beginning of the entry is marked by an open bracket logMonitorIndex Identifies the row of the table The index is particularly important because SNMP does not directly support creation and deletion of MIB objects instead it creates and deletes them as side effects of SNMP Set operations This limitation means that the person creating or modifying Log Monitor table entries through the watch logfile command or by editing sysedge mon must know the exact MIB table index to use for row creation logMonitorLogFile Complete path and file name of the log file to be monitored logMonitorRegularExpression Regular expression to apply when scanning the log file for matches For information about the rules for specifying regula
113. systems 168 240 groups of processes 203 319 host system 234 httpd process monitoring example in sysedge mon 505 I O buffers 184 input packet rate 270 interrupt rate 267 kernel configuration 168 kernel performance 178 log files edgewatch utility 345 overview 333 sample Log Monitor table 204 sysedge mon example 507 message buffers 182 mounted devices 167 netscape process edgewatch 314 sysedge mon 502 NFS facilities 186 number of processes 274 output packet rate 270 page fault rate 268 partitions for disk storage devices 239 process groups with watch procgroup 329 size 309 status 302 process attributes 287 processes 203 281 processors 238 queues 180 root file system 271 RPC facilities 185 running processes 174 software 241 semaphores 180 sendmail 307 services 281 shared memory 180 Simple TCP IP Services service 308 Index 537 size of netscape process 502 SNMP packets received 271 storage areas 236 streams 183 Streams subsystem 170 system information 166 TCPSVCS process 307 thresholds 202 user account information 172 groups 173 logged on to system 176 voice quality 38 Windows cache performance 194 event logs 358 510 events 197 memory performance 195 page file performance 197 performance extensions 199 registry 191 405 services 192 system 188 system performance 193 threads 190 Xterm processes 330 ypbind process edgewatch 313 watch procAlive 308 monolithic agents 159 Mounted Devices table
114. table description field For example you can use the description in conjunction with file system monitoring to indicate that a Critical event occurs when the file system is over 95 full with a message similar to the following Critical filesystem over 95 full When management software receives a trap message it can easily identify the severity level using the description string that is already included within applicable trap messages The description string provides an easy to read method for indicating severity rather than one that requires specialized management station coding or modification Required and Recommended System Patches The SystemEDGE agent requires few if any system patches for proper functioning Unless your platform and operating system release are mentioned in this section you do not need any known patches For the latest information about patches refer to the eHealth Support Web site http support concord com The following patch is recommended for Solaris 2 6 systems Solaris 2 6 105742 updates the le drivers to better support MIB 2 Requires patch 105181 05 or newer Patch 105795 fixes the hme driver so that it indicates ifSpeed The following patches are recommended for HP UX systems e HP UX 11 0 64 bit XSWGR1100 revision B 11 00 49 3 or later is required or patch PHNE 19984 This bundle provides a missing system library e HP UX 11 11 PHNE 27063 s700 800 11 11 cumulative ARP
115. table row creation for the Process Monitor table Perform an SNMP Get of this variable to return an unused index number for the Process Monitor table pmonMatchDescr Read Write You can use this MIB object with the pnmonMatchIndex MIB object to determine the index number that corresponds to a particular entry description Perform an SNMP Set of this MIB object to cause the agent to search through entries in the Process Monitor table and place the index value of the last entry whose description matches in the pnonMatchIndex MIB object pmonMatchIndex Read Only You can use this MIB object with pmonMatchDescr to match a particular entry description with its index number Process Monitor Table Flags The pmonFlags column in the Process Monitor table is a 32 bit unsigned integer field that can specify additional behavioral semantics for the corresponding row By default the Process Monitor table row does the following e Attempts to reinitialize itself Sends SNMP traps e Logs syslog events Invokes actions if they are configured You can set different flag bits to alter these defaults The agent interprets all flags in hexadecimal base 16 notation Figure 39 shows the composition of the Process Monitor table flags pmonFlags field eHealth SystemEDGE User Guide 290 e Chapter 11 Configuring Process and Service Monitoring Ws bits network byte order ____ 12 bits for flag value 12 bits table specitic flags
116. that it is monitoring for a regular expression Consequently it sets the status of the corresponding Log Monitor table row to notReady stat of extension command file X failed The SystemEDGE agent could not determine file information for the extension command that corresponds to extension variable x Consequently the agent will not support extension variable x The agent will support all other valid extension variables For more information about extending the SystemEDGE agent refer to Chapter 16 Adding Custom MIB Objects stat of logmon action X failed The SystemEDGE agent could not determine file information about an action command file that is used with a Log Monitor configuration file statement Consequently it sets the status of the corresponding Log Monitor table row to notReady stat of monfilesys action X failed eHealth SystemEDGE User Guide The SystemEDGE agent could not determine file information about an action command file that is used with a monfilesys configuration file statement Consequently it sets the status of the corresponding Monitor table row to notReady SystemEDGE Agent Error Messages 467 stat of monprocess action X failed The SystemEDGE agent could not determine file information about an action command file that is used with a monprocess configuration file statement Consequently it sets the status of the corresponding Process Monitor table row to notReady stat of nteventmon action X
117. the NT Event Monitor table NT Event Monitor table entries are stored in the sysedge mon file which ensures that they will not be lost when the SystemEDGE agent restarts In addition the watch ntevent directives in the sysedge cf file will create an NT Event Monitor Removing NT Event Monitoring Entries 377 entry whenever the SystemEDGE agent starts This row creation results in a new NT Event Monitor table entry that will be stored in sysedge mon Thus permanent removal of an NT Event Monitor Table entry requires two steps 1 Remove the entry from the sysedge cf file 2 Remove the entry from the NT Event Monitor table Removing Entries from the sysedge cf File If you configured an entry by adding a watch ntevent directive to the sysedge cf file you must remove it from that file as part of removing the entry from the table If you do not remove the sysedge cf directive the entry will be recreated the next time the SystemEDGE agent is restarted Removing Entries with the edgemon Utility To remove an entry from the NT Event Monitor Table use the edgemon utility to delete the entry The following example deletes row 14 from the NT Event Monitor table on host 143 45 0 12 Once deleted the row will be removed both from memory and from the sysedge mon file edgemon 143 45 0 12 private ntevent delete 14 Removing Entries Manually In some cases you cannot use the edgemon utility to delete NT Event Monitor Table entries For e
118. the SystemEDGE agent This problem can occur if you are running the SystemEDGE agent as a user other than the root user to open kmem On UNIX systems the SystemEDGE agent reads the kmem file to retrieve certain kernel parameters and statistics This error message indicates that the agent could not open the dev kmem file perhaps because of permissions problems Verify that the agent has read access to dev kmem to open mnttab file On UNIX systems the SystemEDGE agent was unable to open the system file that indicates which file systems were mounted and are accessible to users Although the SystemEDGE agent will continue to operate it may be unable to answer SNMP queries regarding file systems disks and partitions Verify that the system specific mounted file system file exists and that it is readable by the SystemEDGE agent SystemEDGE Agent Error Messages 451 failed to open create mon file The SystemEDGE agent was unable to open or create a monitor configuration file When the SystemEDGE agent s in memory monitor table changes it is written out in ASCII format to the monitor table configuration file This message indicates that the operation failed The SystemEDGE agent will continue to operate and will continue to monitor MIB objects based on its in memory monitor table However that contents of the in memory monitor table may be lost if the agent is restarted before it can properly save the data failed to open ope
119. the log entry that matched the expression For more information refer to Chapter 13 Configuring Log File Monitoring Using eHealth SystemEDGE 33 Windows Event Monitoring SystemEDGE can also monitor Windows event logs for important event types event identifiers or events that match specific regular expressions Whenever an event that matches the search criteria occurs SystemEDGE notifies the NMS through an SNMP trap For more information refer to Chapter 14 Configuring Windows Event Monitoring History Collection You can configure the SystemEDGE History Control Table to sample MIB variables and to use the collected data for baselining and trend analysis of your system without having to constantly poll from the NMS SystemEDGE collects the data and the NMS can periodically retrieve the history For more information about configuring SystemEDGE history collection refer to Chapter 15 Configuring History Collection NOTE SystemEDGE history collection capability is short term only Use eHealth for long term history collection For more information about using eHealth to monitor your systems refer to the eHealth System and Application Administration Guide Identifying Top Processes SystemEDGE provides a flexible architecture that supports the addition of plug in modules for monitoring processes and applications One of these plug ins is the Top Processes application insight module AIM through whic
120. the trap communities through the Control Panel Network application For more information refer to Configuring Trap Communities on page 130 Common Problems and Questions 429 Is the SystemEDGE Agent Sending Traps To verify whether the SystemEDGE agent is sending traps do the following e On UNIX systems examine the syslog log files e On Windows systems examine SystemROOt system32 sysedge log Is the Management System Configured Correctly To verify that the management system has been properly configured make sure that the empire asn1 file has been imported into the management station so that it knows the format of SNMP Trap PDUs that are generated by the SystemEDGE agent For more information about troubleshooting the management system software contact your management system vendor SystemEDGE Agent Not Accepting Valid License If the SystemEDGE agent is not operating even if a valid license exists in the agent s license file you must verify that the agent is reading the correct license file that the license was correctly entered and that you supplied the correct license information supplied to CA Is the SystemEDGE Agent Reading the Correct License File To verify that the agent is reading the correct license file do the following e On UNIX systems the correct file is etc sysedge lic by default e On Windows systems the correct file is SystemROOt system32 sysedge lic eHealth SystemE
121. these counters to detect peak periods of RPC activity Statistics and counters are divided according to their applicability towards client and server side protocol operations For more information on RPC refer to RFC 1057 The following are the RPC group MIB objects e clientRPCCalls 1 e clientRPCBadcalls 2 e clientRPCRetrans 3 e clientRPCBadxid 4 e clientRPCTimeout 5 e clientRPCWait 6 e clientRPCNewcred 7 e clientRPCTimers 8 e serverRPCCalls 9 e serverRPCBadcalls 10 e serverRPCNullrecv 11 e serverRPCBadlen 12 e serverRPCXdrcall 13 eHealth SystemEDGE User Guide 186 e Chapter 7 Systems Management MIB NFS Group eHealth SystemEDGE User Guide For descriptions of these MIB objects refer to the empire asn1 file in the doc subdirectory of the SystemEDGE agent distribution Use the NFS group to track statistics and counters that are related to the use of the kernel s NFS facilities You can graph the values of these counters to detect peak periods of NFS activity Statistics and counters are divided according to their applicability towards client and server side protocol operations For more information on NFS refer to RFC 1094 The following are the NFS group MIB objects clientNFSCalls 1 clientNFSBadcalls 2 clientNFSNclgets 3 clientNFSNclsleeps 4 clientNFSNulls 5 clientNFSGetattrs 6 clientNFSSetattrs 7 clientNFSRoots 8 clientNFSLookups 9 clientNFSReadlinks 10 clientNFSReads 11 clientNFSWrca
122. through SNMP In addition you can access performance statistics for many applications through the SystemEDGE Systems Management MIB ntRegPerf Group The SystemEDGE agent provides the support for these additional configuration and performance parameters in the ntRegPerf group of the Systems Management MIB This group contains 128 unspecified scalar MIB variables that you can configure In response to a SNMP Get request for one of these variables the SystemEDGE agent will read the Windows registry and return the value obtained 404 e Chapter 17 Adding Windows Registry and Performance MIB Objects Figure 57 shows two sample ntRegPerf variables that are distributed with the SystemEDGE agent Ms ntEvents bh ntEventMonTable 4 ntRegePerfUumpFileti ntRegPerf 7 Ja ntReghumberOUFThreadst2 monitorlablet1 monitorEntrytl Figure 57 Sample ntRegPerf Group Windows Registry and Performance Functionality eHealth SystemEDGE User Guide The ntRegPerf group of the Systems Management MIB is located at OID 1 3 6 1 4 1 546 5 7 This group provides a space for up to 128 user defined scalar MIB variables These new variables are numbered 1 through 128 and are referenced just like any other scalar MIB object For example ntRegPerf object 1 is referred to in Get request messages as 1 3 6 1 4 1 546 5 7 1 0 In all cases ntRegPerf variables use the object instance identifier of 0 An ntRegPerf variable can be any valid bas
123. to Chapter 4 Configuring the SystemEDGE Agent eHealth SystemEDGE User Guide 428 e Chapter 19 Troubleshooting and Usage Suggestions Is the Management System Software Configured Correctly To verify that the management system software is correctly configured check to see that it is querying the correct system and port number if the SystemEDGE agent is running on an alternate UDP port for example on UDP 1691 Management System Not Receiving SNMP Trap Messages eHealth SystemEDGE User Guide If the management system is not receiving SNMP traps from the SystemEDGE agent you must verify that the agent is sending Trap PDUs and that it is sending them to the correct addresses If you have already verified those conditions the problem is most likely due to misconfiguration of the management system Is the SystemEDGE Agent Running To verify that the agent is running refer to Agent Not Responding to SNMP Requests on page 425 Is the SystemEDGE Agent Correctly Configured to Send Trap Messages To verify that the agent is configured to send trap messages to the appropriate addresses do one of the following e On UNIX systems verify the trap communities in the sysedge cf file For example make sure that only one IP address is specified for each trap community statement For more information on trap community configuration refer to Chapter 4 Configuring the SystemEDGE Agent e On Windows systems verify
124. to delete the entry The following example deletes row 14 from the Process Monitor table on host 143 45 0 12 Once deleted the row will be removed both from memory and from the sysedge mon file edgemon 143 45 0 12 private process delete 14 Removing Entries Manually eHealth SystemEDGE User Guide In some cases it may not be possible to use the edgemon utility to delete Process Monitor table entries For example if you have configured the SystemEDGE agent to disallow SNMP Set operations the edgemon utility does not work In this case you must remove the entry from the Process Monitor table by editing the sysedge mon file to remove the entry Because this is an active file you must stop the SystemEDGE agent before editing the file For more information on the format of this file refer to Appendix C For example to delete row 14 1 Stop the SystemEDGE agent 2 Open sysedge mon for editing delete the entry for processmon row 14 and save the file 3 Open sysedge cf for editing delete the entry for processmon row 14 if it exists and save the file 4 Restart the SystemEDGE agent Recommendations for Process and Service Monitoring 317 Recommendations for Process and Service Monitoring When you are configuring process and service monitoring consider the following e Monitor the following Status of the processes e Use the processState operating system dependent or processStateStr operating system in
125. to indicate that a monitor event has occurred The agent sends this trap when the expression monCurrVal monOperator monValue evaluates to True monitorEvent OBJECT IDENTIFIER traps 1 monitorTrap TRAP TYPE ENTERPRISE empire VARIABLES monDescr monOID monCurrVal monValue monRowStatus monOperator monIndex monFlags DESCRIPTION A Monitor event has occurred Recall a monitor event occurs when a Monitor Table row expression evaluates to true The expression is monCurrVal monOperator monValue Format of Trap PDUs 217 monitorEntryNotReady Trap The following code shows the format of a monitorEntryNotReady trap which the SystemEDGE agent sends to indicate that the monRowStatus field of a Monitor table entry is set to notReady 3 monitorEntryNotReadyEvent OBJECT IDENTIFIER traps 3 monitorEntryNotReadyTrap TRAP TYPE ENTERPRISE empire VARIABLES monDescr monOlID monCurrVal monValue monRowStatus monOperator monIndex monFlags DESCRIPTION This trap is sent when a Monitor Table entry s monRowStatus is set to notReady 3 One reason this may occur is that the object instance identifier being monitored by its corresponding Monitor Table entry is no longer in existence For example when a process is being monitored via the Empire processTable and that process should exit its corresponding entry in the Empire processTable would no longer exist Consequently the object instance identifie
126. valid license for machine X 442 couldn t fork sub shell 0 0 0 cece eee eee eee 442 counterType X not supported Entry will not be added 443 CreateEvent for traps failed 0 cc cece eee ee 443 createMutex failed for query mutex 0406 443 createMutex failed for result mutex 443 dev lan is missing SystemEDGE cannot continue 444 dkiotime read failed no disk stats 00006 444 discovering HPUX devices by hand 444 empire agent iit falledso cnphedoncndds ceeana yee eased 444 error parsing X in monitor file line Y 444 event regcomp failed X desc_filt 00 00 0005 444 executing subprograms as group X 2 eee eee eee 445 executing subprograms as user Y 00 0 e eee ee eee 445 execv failed for action ccc eee cece eee eens 445 execv failed for extension command 4 445 extension command file X is not a regular file 445 extension filename too long 0 0 cee ee eee eee 446 extension variable X already in use 000 eee 446 failed to add monitor entry index X 00 00 0008 446 eHealth SystemEDGE User Guide Table of Contents e 17 failed to alloc anIDE struct 0 0 cece eee eee 446 failed to alloc space for monitor 0 0 cece ee eee 446 failed to create a trap SCSSIONs 2 120s0 5005 sosseeeeeae 447 failed to create
127. values email exe Self contained sample e mail action script for sending e mail to phones pagers and e mail systems getver exe Extension tool for finding version information from exe or dll files Some exe or dll files do not provide this information but most do restartsvc exe Action program for restarting Windows services in conjunction with process monitoring continued sysvariable exe Command line utility for retrieving select MIB variables in conjunction with scripts Command line utility for retrieving select MIB variables xtrapmon exe Command line utility for receiving and printing SNMP trap messages Subdirectory that contains documentation for the SystemEDGE agent the MIB modules it supports and the command line utilities that are provided with it cffile txt Description of how to specify configuration settings for the agent by placing them in the sysedge cf configuration text file edgemon txt Description of how to use the edgemon command line utility edgewatch txt Description of how to use the edgewatch command line utility eHealth SystemEDGE User Guide 94 e Chapter 2 Installing the SystemEDGE Agent Table 8 SystemEDGE Directories and Files for Windows Systems Page 3 of 3 Directory Pie Bescripton o o doc emphistory txt Description of how to use the emphistory command line continued utility sendtrap txt Description of how to use the sendtrap command line utility sysvariable txt
128. was earlier than Release 3 0 and that it will write updated Release 4 0 monitor configuration files to the file y eHealth SystemEDGE User Guide 472 Appendix A Error Messages Command line Utility Error Messages This section lists the error messages that can occur when you are using the various command line utilities that are included with SystemEDGE These error messages are generally printed to standard error or standard output Messages are sorted alphabetically by tool The utilities included in this section are as follows edgemon e edgewatch e emphistory e nteventmon e sendtrap e snmpget e sysvariable e walktree e xtrapmon edgemon Error Messages eHealth SystemEDGE User Guide This section describes error messages that may be generated by the edgemon utility bogus port number This message indicates that the optional agent port number that was provided to the monitor command was invalid and either contained non numeric symbols or was negative The requested action therefore was not performed cant resolve address The SystemEDGE agent could not resolve the address or hostname that was provided to the monitor command with a valid IP address and therefore did not perform the requested action Verify that the hostname that was provided has a valid address through tools like host or nslookup Command line Utility Error Messages 473 Couldn t find filesystem at target host The file system nam
129. with any parameters to be executed when the expression evaluates to True and the agent sends a trap If the string is empty the agent performs no action for this entry Unsigned integer flags value that indicates additional behavioral semantics that this row should follow during the course of its operation For more information refer to Monitor Table Flags on page 252 createAndWait 5 The Monitor Table 251 Figure 30 shows a sample Monitor table e SNMP Table Display Table monitorTable Path 1 5 6 1 4 1 546 6 1 1 Rowst10 Columns316 monDescr monInterval monSampleType monOID monCurr al monOperator monvalue 1 minute load average 60 absolute alue 1 loadAveragelMin 0 0 gt 2 300 5 minute load average 300 absolute alue 1 loadAverageSMin 0 5 gt lt 2 200 15 minute load average 900 absoluteV alue 1 loadAveragelSMin 0 alil gtt2 200 Interrupt Rate 60 deltaValue 2 gt numInterrupts 0 25741 gt 2 10000 Page fault Rate 60 deltaValue 2 numPageFaults 0 0 gt 2 1000 leQ Incoming Packets 60 deltaValue 2 gt if InUcastPkts 2 0 gt 2 1000 leQ Outgoing Packets 60 deltaValue 2 gt ifOutUcastPkts 2 0 gt 2 1000 SNMP Packets 30 deltaValue 2 snmpInPkts 0 49 gt lt 2 4000 Num Processes 60 absoluteValue 1 hrSystemProcesses 0 46 gt 2 120 fusr filesystem 60 absolute alue 1 devCapacity 4 78 geid 90 a e _ cae OK estas Figure 30 Systems Management MIB Sample Monitor Table Optimizing Row Creation Yo
130. your other systems Sending an E mail Request for a License Key eHealth SystemEDGE User Guide You can send an e mail request to productlicensing ca com to obtain a license key Include your customer ID and name in all e mail requests CA returns the license key within approximately one business day of the request When you receive the license key through e mail place it in your sysedge lic file NOTE You do not need direct Internet access or SNMP Set permissions to use this method of obtaining a license key Obtaining a License Key 111 Using the Web Based Licensing Form If automated licensing is not available fill out the online Web based license form that is available at the following URL http license concord com 1 Using a Web browser go to the Product licensing Web site at http license concord com and select the Create License option that matches your use of the agent NOTE You must supply a user name and password to access the license form 2 Complete the license form entering the public key that was provided by the SystemEDGE agent You must supply the following information e Name e E mail address SystemEDGE agent release number and patch level e System name e Operating system name and version e System identifier After you submit the license request form the Web server generates a license and displays it in your Web browser It also e mails the license to the contact person in your
131. 0 00 ee 462 not supporting who table cissasscerseenssnasenaews 462 Table of Contents e 19 nteventmon entry X not ready 2 cece eee eee 462 odm_initialize failed 0 ccc eee 462 openProcess failed on pid ccc cece eee ees 462 openProcessToken failed on pid 0 e eee eee 463 openprom device not supported 0 000 eee ee eee 463 perfDiskObjects X Num_Disks 2005 463 realloc of mnt cache failed 0 0 eee eee eee ee 463 FECVINOM LANG geen ca bwentend peateats30Gee araoudes 463 reload_process_table open proc failed 463 reload_process_table proc ioctl failed 464 root device ptr failed no openprom 0 008 464 sent SIGKILE to process Xosccricrissasdiie pissas anats 464 sent signal X to process X cece cece eee eee eens 464 setLogmonEntry invalid set logfile row of status 465 setMonEntry bad size for OID val 00 000 465 setMonEntry invalid oper 0 0 cece eee eee eee 465 setMonEntry invalid oper type 00 e eee ee eee eee 465 setMonEntry invalid stype 2 ce cece eee eee eee 465 setMonEntry invalid type for OID 005 465 setMonEntry invalid type for val 0 e eee eee 465 setMonEntry oid type invalid 0 cee ee eee ee 466 setMonEntry stype type invalid 200 e eae 466 Stat loghlename failed i 0n 2c ecccreudeaeaes codued
132. 00 for monitoring the total amount of CPU available Use AdvantEDGE View Template Management to apply your self monitoring entries to groups of systems For more information about using standard index rows refer to Assigning Entry Rows for the Monitor Table on page 257 For more information about AdvantEDGE View refer to the eHealth AdvantEDGE View User Guide Base any de duplication on source index number or matched string within the trap not on trap type alone eHealth SystemEDGE User Guide 46 e Chapter 1 Introduction eHealth SystemEDGE User Guide e Keep the following points in mind as you create entries that you can use across multiple systems Monitor total CPU utilization states which allow the configuration to be portable across single and multi processor systems Monitor thresholds and configure SystemEDGE to send a limited number of traps for example two or three to prevent flooding of the NMS Enable Clear events to specify resetting of the event in the agent and the status in an NMS For more information about effectively monitoring thresholds and clearing traps refer to Monitor Table Flags on page 252 When you are managing a large network hundreds or thousands of systems and polling each system for granular data at intervals of less than 15 minutes do the following Use history collection to gain highly granular data at the agent level and let the management
133. 1 shows the AdvantEDGE View interface Workstation AdvantEDGE View a AaieSexeceen Zier LES ETT See ed CPU Stateetics Information for aview preset ieme oe natat Server tee ZETI ii i is i iy ar ae systemEDGE D ee St at oe Figure 1 AdvantEDGE View Using eHealth Service Availability eHealth Service Availability is a plug in to the SystemEDGE agent that provides management and monitoring of the response time and availability of the following Internet services e Active Directory Dynamic Host Configuration Protocol DHCP Domain Name System DNS File Input Output I O File Transfer Protocol FTP eHealth SystemEDGE User Guide 38 e Chapter 1 Introduction e Hypertext Transfer Protocol HTTP and secure HTTP HTTPS Internet Message Access Protocol IMAP e Lightweight Directory Access Protocol LDAP e Messaging Application Program Interface MAPI Windows only e Network Information System NIS NIS e Network News Transfer Protocol NNTP e Packet internetwork groper PING e Post Office Protocol POP3 e Round Trip E mail e Simple Mail Transfer Protocol SMTP e Simple Network Management Protocol SNMP e SQL Query e TCP Connect e Trivial File Transfer Protocol TFTP You can also test custom scripts with the Custom test and WinTask record playback scripts with the Virtual User test For more information refer to the Service
134. 10 11 12 13 14 15 16 pmonDescr Monitor netscape Monitor netscape size Monitor sendmail Monitor xcale x 3 Monitor NIS Monitor ypserver Monitor ypbind Monitor Samba Daemon pmonInterval 30 60 60 60 60 60 60 60 Monitor Samba Name Daemon 60 pmonSampleType absoluteValue 1 absoluteValue 1 absoluteValue 1 absoluteValue 1 absoluteValue 1 absoluteValue 1 absoluteValue 1 absoluteValue 1 absoluteValue 1 pmonAttribute processAlive 1 processSize 3 processAlive 1 processAlive 1 processAlive 1 processAlive 1 processAlive 1 processAlive 1 processAlive 1 pmonCurrVal 0 0 3 0 0 0 0 0 0 pmonOperator eqi6 gt 2 eq 6 eq 6 eq 6 eq 6 eq 6 eq 6 eq 6 esta Figure 16 Systems Management MIB Sample Process Monitor Table For more information about using the Process Monitor table refer to Chapter 11 Configuring Process and Service Monitoring Process Group Monitor Table The Process Group Monitor table provides a powerful and flexible mechanism for monitoring groups of processes Figure 17 shows a sample Process Group Monitor table eHealth SystemEDGE User Guide 204 e Table processbrouphonTable Chapter 7 Systems Management MIB Fath 1 3 6 1 4 1 546 15 10 1 Fows 4 Columne 2 Instance pgmonIndex 1 1 2 2 5 5 text Pase pqmonlescr pgmoninterval pgmonProackegExpr pgmonF lags pqmonNumProcs Watch NFS Server Bt nfed
135. 17 Adding Windows Registry and Performance MIB Objects NOTE CA recommends that you use the sysedge cf file rather than the sysedge mon file for manually adding entries to the monitoring tables and configuring the agent The sysedge mon file is a backing store for the agent s self monitoring tables The two files interact and entries in sysedge cf file take precedence over entries in sysedge mon The sysedge cf file is static and cannot be edited remotely The sysedge mon file is not static so AdvantEDGE View and other management software can update this file through SNMP Sets eHealth SystemEDGE User Guide Reviewing the Configuration Files 89 Configuration Files for UNIX Systems By default the SystemEDGE agent looks for the configuration files in the etc directory The SystemEDGE agent installation script installs these files into that directory automatically during the installation unless the directory already includes files with those names that is if you are performing an upgrade instead of a new installation You need to copy these files manually only if you installed the SystemEDGE agent as an upgrade Edit these files to match your local requirements NOTE If you installed the SystemEDGE agent as an upgrade review the new files in EMPsysedge config to identify the latest features and then integrate them with your current configuration files You can also instruct the SystemEDGE agent to look for th
136. 3 Figure 5 shows the user account information in a sample User table SNMP Table Display Tablet userTable Path 1 3 6 1 4 1 546 1 1 2 1 Rows 10 Columns38 userLoginID syne sysdiag sundiag empire cheryl userPassud JFND7386DLYkM oauPmwSD0x47 I Gn tNdTFkLd6 7SHTBH ygl Yul TEMeyOpdipilld rol2FSeZ6310 userUID userGID userName userHomeDir userShel Al al ri fbin syne 0 1 Old System Diagnostic fusr diag sysdiag fusr diag sysdiag sysc 0 al System Diagnostic fusr diag sundiag fusr diag sundiag sunc 6170 10 Empire kingdom empire fbin csh 6168 10 Cheryl Krupezak kingdom chery bin csh 6169 10 Gnats Bug Administration kingdom empire gnats fbin csh 6180 10 Empire Technologies Demo home demo fbin csh 24515 10 Russell J Clark kingdom rjc fusr local bin tesh 6169 10 Bobby Krupezak kingdom rdk fusr local bin tesh 24516 10 Pat Krupezak kingdom mom fbin csh Li eHealth SystemEDGE User Guide este Figure 5 Systems Management MIB User Table Group Information 173 Group Information Use the Group table to retrieve information about the user groups that have been created on the host system Each row in the table represents a group defined in the etc group file including the following information for each group e Group name e Group password e Group ID NOTE Depending on your local security policies you may want to disable support for this table For more i
137. 31 OctetString ReadWrite opt EMPsysedge contrib ping sh For Windows systems enter the following in the SystemRoot System32 sysedge cf file extension 31 OctetString ReadWrite c sysedge contrib ping bat The instance identifier of this object in both examples is 1 3 6 1 4 1 546 14 31 0 To use this feature first Set the variable with the name or IP address of the destination you would like to ping Then when you Get the variable the agent returns the output from the ping attempt Writing Extension Scripts The SystemEDGE agent places very few constraints on the operation of extension scripts It does however require two things All operations Set Get or GetNext must have output The output of Set invocations should echo the value that was actually Set while the output of Get and GetNext should be the object s value If there is no output the SNMP query will fail e Output from extension scripts is only parsed up through the first newline character If a newline is the first character the output is considered NULL causing the SNMP query to fail and returning an error eHealth SystemEDGE User Guide 398 e Chapter 16 Adding Custom MIB Objects NOTE Because the SystemEDGE agent runs as root or administrator you must ensure that all commands and scripts use absolute pathnames are fully debugged and contain no ambiguous code or unnecessary options On Windows systems you can use batch files for writing
138. 4 Configuring the SystemEDGE Agent Access Communities Upon installation the SystemEDGE agent is configured with only one community named public This community provides read only access to the agent s MIB object values For security reasons the default configuration does not define a read write community The agent s configuration file contains a sample read write community but it is commented out Before you can modify set the agent s MIB values you must define a community that provides read write access For information about configuring your own SNMP communities for the agent refer to Configuring Access Communities on page 128 eHealth SystemEDGE User Guide 90 e Chapter 1 ntroduction eHealth SystemEDGE User Guide Trap Communities The Trap community indicates which management systems should receive the trap messages that the agent generates The agent s self monitoring features report exception conditions by sending trap messages to the management systems in the trap community For information about configuring the SystemEDGE agent to send traps refer to Configuring Trap Communities on page 130 For information about the types of traps that the SystemEDGE agent can send refer to Chapter 8 Private Enterprise Traps Installing the SystemEDGE Agent This chapter explains how to install the SystemEDGE agent Use Table 5 to find the installation procedure for your operating system
139. 5 minute load average monitor oid loadAveragel5Min 0 13 0x0 900 absolute gt 200 Monitor 15 minute load average The values in this example are defined as follows e loadAveragel5Min 0 corresponds to the OID for the loadAverage15Min variable contained within the Systems Management MIB e 13 indicates that this entry will occupy row 13 monIndex 13 in the Monitor table e 900 specifies that the load average should be sampled once every 900 seconds e absolute indicates that the agent should use the object s value not the difference between successive samples eHealth SystemEDGE User Guide Threshold Monitoring Examples 267 e 200 is the value against which the current load average is compared If the currently sampled value is greater than gt 200 the agent sends a trap to all configured managers e indicates that no action is specified Monitoring the System s Interrupt Rate The following example configures the SystemEDGE agent to monitor the rate at which hardware interrupts are occurring on the local system monitor oid numiInterrupts 0 14 0x00500400 60 delta gt 1000 Monitor Interrupt Rate The values in this example are defined as follows e numlInterrupts 0 is the OID for the numInterrupts counter object contained within the Systems Management MIB e 14 indicates that the entry is index 14 in the Monitor table The flags field of 0x00500400 does the following Configures the
140. 52 failed to reload utmp cache 0c c eee eee ee ees 452 failed to rename mon file 0 cece cee eee eee 453 failed to allocate history entry 0 cece eee eee 453 failed to send COLDSTART trap 0 0 0 0 cece eee 453 fork failed for extension command 006 453 fork failed for monitor action 02 cece eee eee 453 fork failed for logmonitor action 006 454 PPE SIGN al CaUCMt 1 iva sud oie setae akaeen Sor Geeee es 454 WIG 2 eacce caeeesouteseaatmaneeesaeheedhaameed ex 454 identical threads IDS 5 0 204 08ibordentearnaredentee ms 454 eHealth SystemEDGE User Guide 18 o Table of Contents eHealth SystemEDGE User Guide invalid extension variable access mode 2005 454 invalid extension variable type X 0 cee ee ee eee 455 invalid history description 02 0 eee eee eee ee 455 invalid history object type eee cece ee eee eee 455 Invalid monitor table index 0 0 0 ce eee eee 455 invalid monprocess regular expression 000 456 invalid NT event log name 0 eee ee ee eens 456 invalid NT event type lt 2ds 4ccu 00540e464e05endaa dunes 456 invalid number history buckets 0 00 c eee eee 456 invalid SNMP variable type X cece eee eee 456 lock of mnttab lock failed 0 0 eee eee 456 license file etc sysedge lic not found 4 457 license file not found c
141. 62 sews scacescesaneceancedeceeeaws 471 Using MONIO MIC cleachuensaeeaentesaconesesse ateen 471 using old config file 6 eee ce eee eens 471 using old monitor file X updates will be placed in Y 471 Command line Utility Error Messages 00005 472 edgemon Error Messages 0 cece cece eee eee eees 472 edgewatch Error Messages 0c cece eee cece eeees 474 emphistory Error Messages 00 0 cece cee ee cues 478 nteventmon Error MeSssaSess c 20s viadendriaetetareusdes 479 sendtrap Error Messages 0 cece cece eee eee eees 431 snmpget Error Messages 0 cee eee eee eee 483 sysvariable Error Messages eee e cece cee eeeees 484 walktree Error Messages iu cade cdcedanenadee tasapai 485 xtrapmon Error Messages 0 eee eee eee eee 486 Appendix B Using the syslog Facility 489 Logging syslog Messages 0 cece eee cence eee nnee 489 Creating a Log File for Daemon Messages 00 49 Creating a Daemon Log File for Sun SPARC Systems 492 Creating a Daemon Log File for HP UX Systems 492 eHealth SystemEDGE User Guide Appendix C Appendix D Table of Contents 21 Adding Self Monitoring Entries to the sysedge mon File 493 SystemEDGE Table Backing Store 00005 493 Adding Monitor Table Entries to the sysedge mon File 494 Sample Monitor Table Entries in sysedge mon 497 Monitoring 1 Minute Loa
142. 77 Set to Empire procmon table failed edgewatch failed to Set or create an entry in the SystemEDGE agent s Process Monitor table Verify that the community string and target hostname or IP address are correct and that the community string has read write permission Set to logMonitorTable failed edgewatch failed to Set or create an entry in the SystemEDGE agent s Log Monitor table Verify that the community string and target hostname or IP address are correct and that the community string has read write permission Set to ntEventMionTable failed edgewatch failed to Set or create an entry in the SystemEDGE agent s NT Event Monitor table Verify that the community string and target hostname or IP address are correct and that the community string has read write permission Set to procMon table failed edgewatch failed to Set or create an entry in the SystemEDGE agent s Process Monitor table Verify that the community string and target hostname or IP address are correct and that the community string has read write permission SNMP Operation failed edgewatch failed to get one of the request variables because of an error in the SNMP operation Verify that the community string and target hostname or IP address are correct target host not a Windows NT system edgewatch attempted to perform an operation that the SystemEDGE agent supports only on Windows systems on a system that was not running Windows Therefore it did n
143. 8 MB RAM e At least 4 MB free disk space eHealth SystemEDGE User Guide Installing SystemEDGE on AIX Systems 83 Installing the Software The SystemEDGE agent software distribution for AIX is formatted as an AIX product This distribution uses the smit utility to install the SystemEDGE agent product By default the smit utility places the software in the usr Ipp EMPsysedge directory When you run the installation script you must enter valid values for all prompts If you enter invalid values or press Enter at a prompt that requires a value and does not offer a default value the script will not complete properly If the script generates an error message or is unable to complete you must run the script again and specify valid values for all prompts To install the software 1 Log in as root by entering su and then the root password at the password prompt Insert the CD containing the software distributions into the CD ROM drive and mount it using the AIX command smit mountfs Mount the CD ROM as cdrom NOTE You can select another mount point but if you do be sure to substitute your mount point in place of cdrom in the following instructions Run the smit utility by entering the following smit install_latest a Specify cdrom sysedge aix as the software input device b Select EMPsysedge rte as the software to install c Click OK Start the installation script by entering the following comma
144. A Error Messages timeGetDevCaps failed exiting On Windows systems the SystemEDGE agent was unable to get the system s timer resolution capabilities that are necessary for internal operation and self monitoring of MIB objects Consequently the agent will not operate This problem is most likely due to an error on the underlying Windows system To resolve this problem reboot the Windows system timeKillEvent failed On Windows systems the SystemEDGE agent delays its initialization in order to avoid potential race conditions that can be created by the order in which the registry and services are initialized This error message indicates that the SystemEDGE agent could not stop its internal timer event from firing The problem most likely is due to an error on the underlying Windows system To resolve this problem reboot the Windows system trap ipaddress hostname X invalid On UNIX systems the sysedge cf configuration file indicates to which hosts the SystemEDGE agent should send SNMP trap messages This error indicates that one of the trap statements in the sysedge cf configuration file specifies an incorrect hostname or IP address The agent will ignore the offending trap statement but will parse the rest of the configuration file turning off process table support The SystemEDGE agent is disabling support of the process table according to the configuration file directive turning off sets to Empire process table The Syst
145. A Transport patch or later is recommended This patch fixes memory issues with HP UX libraries eHealth SystemEDGE User Guide Error Messages This chapter describes error messages you may encounter while using the SystemEDGE agent The error messages are organized by type into the following groups e SystemEDGE agent error messages e Command line utility error messages SystemEDGE Agent Error Messages This section describes the error messages that you may encounter when using the SystemEDGE agent Depending on the error the message will either be printed to standard error or logged through the syslog utility The messages in this appendix are sorted alphabetically action execution failed The SystemEDGE agent failed to execute an action command due to an error Check your action script name and arguments authenFailure src A B C D community X The SystemEDGE agent has sent an SNMP authentication failure trap message because it does not permit SNMP queries using community x from IP address A B C D 439 440 e Appendix A Error Messages bad ioconfig magic Upon startup the SystemEDGE agent uses whatever operating system support is available to attempt to discover the devices that are contained in the underlying system This error message indicates the SystemEDGE agent could not properly read the HP UX file etc ioconfig and will therefore attempt to discover devices without the operating system s aid bad pid X
146. Configuring Process and Service Monitoring Table 43 Watch Process Parameters Page 2 of 2 threshold Integer value threshold to which the agent compares the current value either absolute or delta description Quoted string that is 0 to 128 characters in length and that normally contains a description of the process and attribute that are being monitored as well as severity level aCELoOn Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the process starts or stops If the string is empty the agent performs no action for this entry The watch process configuration file directive automatically creates the following boolean expression for the Process Monitor table entry attribute operator threshold When this expression evaluates to True the SystemEDGE agent sends a processThreshold SNMP trap If you have configured an action the agent invokes it If the process has died the Process Monitor table entry becomes notReady and the agent sends a notReady SNMP trap However if the process restarts the agent automatically reinitializes the corresponding Process Monitor table entry reacquires the PID and continues monitoring that process attribute for the specified threshold Process Monitoring Examples This section contains sample configuration file directives for process monitoring Each example shows how to define an ins
147. D for the loadAverage5 Minute variable contained within the Systems Management MIB 12 indicates that this entry will occupy row 12 monIndex 12 in the Monitor table The flags field of 0x00500300 does the following Configures the agent to send monitorClear traps when the threshold expression transitions from True to False Configures the agent to begin sending traps and execute actions if they are configured only at the xth consecutive occurrence of the event Specifies that x 5 That is the agent begins to send traps at the fifth occurrence of the event 300 specifies that the load average should be sampled once every 300 seconds absolute indicates that the agent should use the object s value not the difference between successive samples 200 is the value against which the current load average is compared If the currently sampled value is greater than gt 200 the agent sends a trap to all configured managers indicates that no action is specified eHealth SystemEDGE User Guide 266 e Chapter 10 Configuring Threshold Monitoring Figure 35 shows how the agent would send and clear traps based on this monitor directive Sample Trap Sent ample No Trap Sent E ample Clear Trap Sent a Flags 000500300 200 Tir Figure 35 Monitoring the 5 Minute Load Average Monitoring the 15 Minute Load Average The following example configures the SystemEDGE agent to monitor the system s 1
148. DGE User Guide 430 e Chapter 19 Troubleshooting and Usage Suggestions Was the License Entered Correctly into the License File To verify that the license is correct compare the license key in the license file to the one that was provided by CA For example verify that O s and 0 s and I s and 1 s were not transposed Was the Correct License Information Supplied to CA Verify that the license information you supplied to CA matches your system This information which was generated by the SystemEDGE agent takes the following form SystemEDGE jupiter NTx86 4 0 346561363366b19c 4 1 Patchlevel 1 For more information about licensing refer to Chapter 3 Licensing the SystemEDGE Agent Agent Does Not Run on A Particular Operating System Version eHealth SystemEDGE User Guide If the System agent was installed on an operating system on which it does not run the agent displays a message similar to the following when it starts for the first time after installation This agent binary is compiled for xX not Y Because the SystemEDGE agent works closely with the underlying operating system each release may require different binaries For example kernel data structures and application programmer interfaces may change from release to release sometimes in subtle ways Therefore for versions of Solaris 2 x and some versions of HP UX 10 x the SystemEDGE agent uses different binaries for each release The error message displaye
149. DGE agent daemon as well as several command line utilities for use with SystemEDGE threshold process process group log and Windows event monitoring and history sampling checkfile exe Program for checking whether a file exists You can use this program as an extension or part of an action script with SystemEDGE email exe Self contained program for sending e mail to phones pagers and e mail systems You can use this program as an action with SystemEDGE SystemEDGE agent executable Command line utility for sending user defined traps edgewatch Command line utility for dynamically configuring the agent to monitor log files and processes edgemon Command line utility for dynamically configuring threshold monitoring emphistory Command line utility for use with history sampling use this utility to specify MIB variables to store over time and to retrieve stored values Sample action script that restarts a process eHealth SystemEDGE User Guide SystemEDGE Agent Directories and Files 91 Table 7 SystemEDGE Directories and Files for UNIX Systems Page 2 of 2 bin sysvariable Command line utility for retrieving select MIB variables in continued conjunction with scripts xtrapmon Command line utility for receiving and printing SNMP trap messages Command line utility for retrieving select MIB variables Subdirectory that contains documentation for the SystemEDGE agent the MIB modules it supports and the command
150. DGE agent for your changes to take effect 118 e Chapter 4 Configuring the SystemEDGE Agent Interactions Between sysedge cf and sysedge mon The SystemEDGE agent uses the sysedge mon file as a backing store for the agent s self monitoring tables The sysedge cf and sysedge mon files interact and entries in sysedge cf file take precedence over entries in sysedge mon The sysedge cf file is static and cannot be edited remotely The sysedge mon file is not static so AdvantEDGE View and other management software can update this file through SNMP Sets If you remove a monitoring entry from sysedge cf and that entry also exists in sysedge mon you must also remove it from sysedge mon to prevent the agent from using it When you add configuration entries to the agent through AdvantEDGE View the entries are stored in sysedge mon and are not added to sysedge cf For more information about using sysedge mon refer to Appendix C Configuring the Agent During the Installation Procedure Before You Begin eHealth SystemEDGE User Guide The SystemEDGE installation enables you to perform some configuration tasks when you install the agent For example you can configure system description and location read only and read write communities and trap destinations during the installation process You can later modify any of those settings by editing the sysedge cf file as described in this chapter Make sure that your installation has copied the s
151. EDGE User Guide NT Event Monitor Table Flags 363 Optimizing Row Creation You can use the following MIB objects with the NT Event Monitor table to optimize row creation Table 64 Scalar Objects for Optimizing Row Creation ntEventUnusedIndex Read Only You can use this variable to optimize table row creation for the NT Event Monitor table Perform an SNMP Get of this variable to return an unused index number for the NT Event Monitor table ntEventMatchDescr Read Write You can use this MIB object with the ntEventMonMatchIndex MIB object to determine the index number that corresponds to a particular entry description Perform an SNMP Set of this MIB object to cause the agent to search through entries in the NT Event Monitor table and place the index value of the last entry whose description matches in the ntEventMonMatchIndex MIB object ntEventMatchIndex Read Only You can use this MIB object with ntEventMonMatchDescr to match a particular entry description with its index number NT Event Monitor Table Flags You can use the ntEventMonFlags column in the NT Event Monitor Table to specify additional behavioral semantics for the corresponding NT Event Monitor table row By default the NT Event Monitor table row does the following Attempts to reinitialize itself Sends SNMP traps e Logs events with the syslog utility Invokes actions if they are configured You can set different flag bits to alter these defaults
152. EDGE agent failed to allocate the resources necessary to send SNMP trap messages most likely because of an error in the underlying system The SystemEDGE agent will continue to operate but will not be able to send SNMP trap messages failed to create timer event X The SystemEDGE agent on a Windows system failed to create a Windows timer event necessary for sub agent initialization and operation The problem is most likely due to an error on the underlying Windows system Unfortunately problems such as this often require you to reboot the Windows system failed to create a trap session The SystemEDGE agent failed to create an internal session to use for sending SNMP traps Consequently the agent may not be able to send SNMP traps failed to create timer event On Windows systems the SystemEDGE agent uses a timer construct to perform periodic processing This message indicates that the agent failed to allocate such a resource Consequently the agent s self monitoring capabilities may not function properly failed to create trap pdu The SystemEDGE agent failed to create an SNMP trap message for transmission to SNMP management systems This error usually occurs when the underlying system is low on memory The SystemEDGE agent will not send the particular SNMP trap message but it will continue to attempt to send subsequent SNMP trap messages eHealth SystemEDGE User Guide 448 e Appendix A Error Messages failed to get dksci
153. EDGE for Windows Systems The uninstall program removes SystemEDGE It also removes the sysedge dll sysedge cf sysedge lic and sysedge mon files from the SystemRoot system32 directory NOTE If you want to save these files copy them to another directory before you run the uninstall utility If you installed the agent with the InstallShield installer refer to the next section If you installed the agent from the command line refer to Uninstalling an Agent from the Command Line on page 101 Uninstalling the SystemEDGE Agent 99 Uninstalling an Agent with InstallShield If you used InstallShield to install the agent you can also use it to remove the agent 1 Log on to the Windows system as administrator 2 Insert the CD that contains the software distributions into the CD ROM drive Windows automatically mounts the drive 3 Double click sysedge exe from the CD ROM to run the self extracting executable The SystemEDGE Maintenance dialog box appears InstallShield Wizard SystemEDGE Maintenance Concord Communications Modify Modify update SustemEDGE Repair ee Repair reinstall SystemEDGE A Remove SystemEDGE InstallShield Back Cancel 4 Select Remove and click Next The following prompt appears eHealth SystemEDGE User Guide 100 Chapter 2 Installing the SystemEDGE Agent Confirm Uninstall E xj re vou sure you want to completely remov
154. EDGE grants access to any system that uses this community string The following restrictions apply to the access list IP addresses must be separated by a space character you cannot use any other characters including the newline The maximum length of a community string statement including any access list is 1024 characters which provides enough space for about 60 IP addresses To configure longer access lists define separate communities e The SystemEDGE agent software distribution includes the edgewatch edgemon and emphistory command line utilities which act as manager systems sending requests to the agent If you are using any of these utilities on the same system on which the agent is installed include that system s IP address in the access list eHealth SystemEDGE User Guide 130 e Chapter 4 Configuring the SystemEDGE Agent Default Settings When the SystemEDGE agent is installed sysedge cf defines a single access community named public which provides read only access to MIB objects The definition appears as follows community public read only NOTE Common practice allows read only access using the community name public To modify the values of MIB objects through SNMP Set operations you must define a community that has read write access permissions For example you could add a definition like the following to the sysedge cf file community private read write Configuring Trap Communities e
155. Editing empire asn1 for ntRegPerf Variables 411 Editing a Separate MIB Specification for ntRegPerf e EET EEE TESE EEE TTET EEES 411 eHealth SystemEDGE User Guide Chapter 18 Chapter 19 Table of Contents e 15 Deploying the SystemEDGE Agent 413 IGM OGUUCION css ceminerenseeene eeiwnaroeenereen et xe 413 Deploying SystemEDGE with AdvantEDGE View 414 How the Automated Deployment Works 414 Deploying SystemEDGE from the Web 415 Deploying SystemEDGE through E mail 416 Third Party Deployment Tools 0 00 cece eee eee 416 Automating Deployment 0 0 cece eee eee eee 417 Making Software Available to Remote Systems 417 Installing Software on Remote Systems 419 Configuring Software for Distributed Systems 419 Licensing Software Remotely 00 c eee eens 420 De CUM ISSUES son dads Learn beta rae acrerens cuenenese 420 Troubleshooting and Usage Suggestions 423 Using diagsysedge exe cece cece eee e eee e neces 423 Determining Whether the Agent Is Running 423 Obtaining a Report for Troubleshooting 424 Common Problems and Questions 00c cee eees 425 Agent Not Responding to SNMP Requests 425 Management System Not Receiving SNMP Trap Messages 428 SystemEDGE Agent Not Accepting Valid License 429 Agent Does Not Run on A Particular Op
156. EventMonFlags Flags that indicate additional behavior eHealth SystemEDGE User Guide Windows Specific Groups 199 NT Registry and Performance Extension Group The SystemEDGE agent provides a powerful mechanism for extending the Systems Management MIB to include information from the Windows registry and performance counters This includes both configuration data normally viewed using regedit and performance data normally viewed using perfmon Using this feature you can customize SystemEDGE to return additional configuration and performance information for systems and applications For instance many applications provide registry entries that specify the configuration of the application The SystemEDGE agent can make these entries available through SNMP using the SystemEDGE agent In addition the SystemEDGE agent can also access statistics that many applications provide This support is provided in the ntRegPerfGroup of the Systems Management MIB This group contains 128 unspecified scalar MIB variables that you can configure In response to a SNMP Get request for one of these variables the SystemEDGE agent reads the Windows Registry and returns the value For more information about using and configuring MIB objects in the NT Registry Performance group refer to Chapter 17 Adding Windows Registry and Performance MIB Objects Unsupported MIB Objects on Windows The SystemEDGE agent for Windows supports the Systems Mana
157. ExceptionDispatches 6 ntFileCtrlkBytes 7 ntFileCtrlOps 8 ntFileDataONps lt 9 ntReadkBytes 10 ntReadOps 11 nthWriteKkKBytes 12 ntWriteOps 13 ntFloatEmuls lt 14 gt ntRun Llen 15 ntSystemCalls 16 ntInterrupts 17 eHealth SystemEDGE User Guide 194 e Chapter 7 Systems Management MIB Detecting a Heavily Loaded System A heavily loaded system typically has a high level of system activity with many process threads competing for CPU time and jobs queueing up as they wait to run You can track the level of system activity by monitoring the ntContextSwitches and ntRunQLen MIB objects ntContextSwitches counts the number of context switches that have occurred A context switch occurs each time a thread gives up the CPU and another takes its place A high rate of context switching indicates a high system load ntRunQLen indicates whether there is a backup of threads waiting to run NT Cache Performance Group eHealth SystemEDGE User Guide The NT Cache Performance group contains system wide buffer and filesystem cache statistics that let you determine the effectiveness of a system s caching mechanisms When an application requests data the data is first mapped into the cache and then copied into memory from the cache Later data that is changed by the application is written from the cache back to disk by the Lazy Writer system thread or by a write through call from the application Monitor the cache performanc
158. GE View Web Help Security Issues eHealth SystemEDGE User Guide System security is a complex problem that involves tradeoffs between usability and system integrity Making a system more secure often infringes on the usability and the ease of use of the underlying system Using an SNMP agent such as the SystemEDGE agent requires some policy decisions about what functionality to permit or restrict This section identifies some of the security issues that you should consider when deploying the SystemEDGE agent Those security issues center on four main points Integrity of the underlying system e SNMPv1 communities Scripts and commands invoked by the SystemEDGE agent e MIB groups Security of the underlying system is important for restricting access to the SystemEDGE agent configuration files configuration monitor and license to only those users who are authorized to read and write them Both read and write access to these files should be restricted e Read access can provide information about valid community names and their respective permissions read only or read write e Write access to these files allows the modification of community names and associated privileges as well as the modification of self monitoring table entries which could be used to execute arbitrary commands Automating Deployment 421 The SystemEDGE agent currently supports SNMPv1 which uses community based security Communities like a passwor
159. Health SystemEDGE User Guide The sysedge cf file contains definitions for trap communities which tell the SystemEDGE agent where to send trap messages You can configure the agent to send traps to any number of management systems The SystemEDGE installation enables you to define trap communities You can define additional communities as described in this section For each management system to which you want to send traps add a line with one of the following formats e trap_community community name ip address e trap_community community name hostname Configuring Trap Communities 131 For example add the following lines to send traps with a communit y name of mycommunity to two systems one with the IP address 10 16 5 26 and the other with the hostname atlanta noc trap_community mycommunity 10 16 5 26 trap_community mycommunity atlanta noc Specifying a Trap Source Optionally you can specify a trap source This parameter enables you to specify the IP address that is sent in SystemEDGE Trap protocol description units PDUs By default SystemEDGE uses whatever value is returned for the system by the gethostbyname function call Specify trap_source if you want to override the default behavior The agent has only one trap source parameter so you set this value only once in sysedge cf and then all traps in all communities will take the address you have specified The address you specify must be a valid IP address but the Sy
160. If a match is found the agent sends an SNMP trap message logmon 2 SU WARNING var adm messages Se ei 0x0 active eHealth SystemEDGE User Guide 908 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Adding NT Event Monitor Table Entries to the sysedge mon File NT Event Monitor table entries begin with the keyword nteventmon They are delineated by open and closed brackets and they include seven fields Table 90 describes the field for NT Event Monitor table entries in the sysedge mon file Table 90 Fields for NT Event Monitor Entries Page 1 of 2 nteventmon Beginning of the entry is marked by an open bracket ntEventMonIndex Identifies the row of the table The index is particularly important because SNMP does not directly support creation and deletion of MIB objects instead it creates and deletes them as side effects of SNMP Set operations This limitation means that the person creating or modifying NT Event Monitor table entries through the watch ntevent command or by editing sysedge mon must know the exact MIB table index to use for row creation ntEventMonDescription Quoted text string that contains a description of the purpose function and optionally creator of the entry ntEventMonLog Integer that designates which Windows Event Log to monitor The following are possible values e Application 1 Security 2 System 3 eHealth SystemEDGE User Guide Adding NT Event
161. InstallShield 12 Specify the port on which you want the SystemEDGE agent to run in the Port field and then click Next Port 161 is the default SNMP port If you run SystemEDGE on this port and you are running the Microsoft SNMP agent you must specify a different port for the Microsoft agent Port 1691 is reserved for use with the SystemEDGE agent You can specify any port that is not in use on the system The following dialog box appears eHealth SystemEDGE User Guide 66 e Chapter 2 Installing the SystemEDGE Agent 13 Click Yes to enable the Top Processes AIM The following dialog box appears SystemEDGE Control Panel Local gent Configuration Information System Description Windows 2003 Database Server System Contact mem Company com System Location Alanta GA Rack 10 Read Community Read winite Communitu Trap Destination SysE0g mon syeedge lic Restart SystemE DGE After Config File Changes Legging Debug Service Control __ spsedgelog diagsysedge Stat Agent Status Started Stop Agent s Version 4 2 Patchlevel 1 Release Notes User Guide eHealth SystemEDGE User Guide 15 16 Installing SystemEDGE on Windows Systems 67 Edit the sysedge cf file a Click sysedge cf The file opens in a text editor b Add community strings or trap destinations You must add a read write community string if you want to license the agent automatically For more informatio
162. MTP Sendmail service Sample multi purpose extension script logfileaction sh Sample log file action script for sending alternative trap formats mailaction sh Sample mail action script for sending a mail message with variable bindings mqcnt Sample extension script for measuring Sendmail queue length ntdist pl Sample script for deploying SystemEDGE agents and eHealth AIMs nteventfilter pl Sample script for filtering NT events and sending traps that look like they are originating from the SystemEDGE agent eHealth SystemEDGE User Guide SystemEDGE Agent Directories and Files 97 Table 9 Directories and Files for All Platforms Page 4 of 4 Directory Fle Desorption SS contrib ping sh Sample extension script for performing remote ping continued operations j restartsvcexe exe Sample action script for restarting a Windows service action script for Sample action script for restarting a Windows service a Windows service E Sample script for paging a PageMart alphanumeric pager smtp listenq sh Sample script that measures the listen backlog of the SMTP port and reports its current length doc Subdirectory that contains documentation for the SystemEDGE agent the MIB modules it supports and the command line utilities that are provided with it empire asn Systems Management MIB specification This document describes the meaning and use of all of the management objects in the Systems Management MIB hos
163. Messages 483 sendtrap WSAStartup failed On Windows systems sendtrap was unable to initialize the WinSock library and could not send the SNMP trap message snmpsend failed The underlying library routine for sending the SNMP Trap PDU failed and no trap PDU was sent warning bogus SNMPv1 Trap type still sending SNMPvI1 trap must be of types 1 through 6 This message indicates that the specified trap type was outside the valid range The trap type was included in the SNMP Trap PDU and it was still sent snmpget Error Messages This section describes error messages that may be generated by the snmpget utility cant resolve address for The address or hostname that was provided to snmpget could not be resolved to a valid IP address so the requested action was not performed Verify that the hostname has a valid address through tools like host or nslookup GET_NEXT failed An error occurred while snmpget was communicating with the SystemEDGE agent Verify that the community string and target IP address or system name are correct The request may or may not have succeeded invalid timeout value The timeout value passed to snmpget was invalid The timeout value if set should be an integer number greater than 0 The requested action therefore was not performed eHealth SystemEDGE User Guide 484 e Appendix A Error Messages snmpget returned object of type instead of snmpget was expecting one object type but
164. Motdt 43 extensionPing sl Figure 19 Systems Management MIB Sample Extension Group Entries For more information about using the Extension group variables refer to Chapter 16 Adding Custom MIB Objects eHealth SystemEDGE User Guide Private Enterprise Traps Variable bindings are optional fields in a Trap PDU that associate a particular object instance with its current value In addition to supporting the standard MIB II traps the SystemEDGE agent supports a number of private enterprise trap types that have been defined for use with the agent s self monitoring capabilities This chapter describes the format of the Trap PDUs that the SystemEDGE agent can send Format of Trap PDUs The Systems Management MIB file empire asn1 defines enterprise specific traps for use with the SystemEDGE agent This section describes the PDU format including the information that is contained in the variable bindings fields for each type of trap NOTE The text in this chapter is taken from the Systems Management MIB definition which exists in the doc subdirectory of the SystemEDGE agent distribution All traps that are sent by the SystemEDGE agent contain the following enterprise system object identifier sysObjectID empire 546 1 1 215 216 e Chapter 8 Private Enterprise Traps monitor Trap eHealth SystemEDGE User Guide The following code shows the format of a monitor trap which the SystemEDGE agent sends
165. NIX systems pgmonMatchGroup Read Write When this object is set to a valid group name SystemEDGE matches running processes by group name as well as process name regular expression and user name This variable is valid only on UNIX systems eHealth SystemEDGE User Guide 324 e Chapter 12 Configuring Process Group Monitoring Figure 46 shows a sample Process Group Monitor table Table processbroupMonTable Fath 1 3 6 1 4 1 546 15 10 1 Rowets Columnez2 Instance pqmon Index pgmanDescr Pgmoninterval pgmonProcRegExpr pqmonF lags pamonNumProcs 1 1 Watch NFS Server Bt nfed a a z Watch Web Server Bt httpd 11 z z Watch SSH Server Bt sshd 2 a Ok est Pae Figure 46 Sample Process Group Monitor Table Optimizing Row Creation You can use the following MIB objects with the Process Group Monitor table to optimize row creation Table 47 Scalar Objects for Optimizing Row Creation pgmonUnusedIndex Read Only You can use this variable to optimize table row creation for the Process Group Monitor table Perform an SNMP Get of this variable to return an unused index number for the Process Group Monitor table pgmonMatchDescr Read Write You can use this MIB object with the pgmonMatchIndex MIB object to determine the index number that corresponds to a particular entry description Perform an SNMP Set of this MIB object to cause the agent to search through entries in the Process Group Monitor table and
166. NT Service MIB table and creates the appropriate entry in the agent s Process Monitor table For more information about the NT Service MIB table refer to Chapter 7 Systems Management MIB Configuring Support for Process Group Monitoring 141 Configuring Support for Process Group Monitoring The flexible Process Group Monitor table of the Systems Management MIB enables you to dynamically configure the SystemEDGE agent to monitor groups of processes that are running on the underlying system You select the process group regular expression and interval and the agent uses that information to monitor those process groups For example the agent can determine what processes exist in each group and whether the group membership changes If components of an application start or fail or if members leave a group or are added to a group the SystemEDGE agent can automatically notify the NMS For more information about creating entries in the Process Monitor table refer to Chapter 12 Configuring Process Group Monitoring Configuring Support for Log File Monitoring The SystemEDGE agent includes a log file monitoring capability that lets you instruct the agent to monitor log files continuously for the appearance of user specified regular expressions and to notify the management system with a trap message if the agent finds a match You can specify entries for log file monitoring dynamically through SNMP Set requests while the ag
167. Perf MIB variables that exist under the Systems Management MIB ntregperfGroup eHealth SystemEDGE User Guide 412 e Chapter 17 Adding Windows Registry and Performance MIB Objects 3 Perform a test compile of the ntregperf asn1 file to ensure that there are no syntax errors This procedure is specific to your management system and its corresponding MIB compiler 4 Import the ntregperf asn1 file into your management system software This procedure is specific to your network management station and its corresponding MIB compiler NOTE If you do not reimport the MIB file your management system software will not be able to access the new MIB objects eHealth SystemEDGE User Guide Deploying the SystemEDGE Agent Introduction This chapter describes deployment options for the SystemEDGE agent Deploying the SystemEDGE agents can be challenging in large distributed environments This chapter provides guidelines and suggestions for automating the deployment of the SystemEDGE agent For small numbers of systems deployment by hand may be advantageous because it requires little configuration or preparation However as the number of systems and locations grows the effort that is required to manually deploy new software grows exponentially SystemEDGE includes a sample set of scripts that you can use to help automate its deployment The scripts are contained in the contrib subdirectory of the SystemEDGE agent distribution
168. Protocol LDAP NFS Network Information Services NIS and Dynamic Host Configuration Protocol DHCP eHealth AIM for Network Vital network services for Services for Windows Windows systems including Active Directory DHCP DNS and Windows Internet Naming Service WINS eHealth SystemEDGE User Guide 40 e Chapter 1 Introduction For more information about these AIMs refer to the user guide for the module in which you are interested Using eHealth with eHealth SystemEDGE eHealth SystemEDGE User Guide You can use the SystemEDGE agent to monitor your eHealth systems and you can use the agent and eHealth together to manage and monitor other systems within your enterprise When you are using the SystemEDGE agent to monitor eHealth you can run the nhAddSysEdgeMonEntries command to configure the agent to monitor critical eHealth processes and system logs The command adds entries to the sysedge cf file and it stops and restarts the SystemEDGE agent to implement the changes For more information about the nhAddSysEdgeMonEntries command refer to the eHealth Administration Reference When you use SystemEDGE with eHealth the eHealth poller can collect data from SystemEDGE agents and store that data in the eHealth database The information is then available to the eHealth reporting and real time monitoring tools You can run At a Glance AAG Trend Top N What If Capacity Trend System Health and MyHealth reports for system
169. RT I1 to SNMP_HPUNIX_START 0 e SNMP_MIB2_START 1 to SNMP_MIB2_START 0 eHealth SystemEDGE User Guide 154 e Chapter 5 Starting the SystemEDGE Agent Starting the Agent Automatically for Linux Systems For Linux systems you must run the SystemEDGE agent s sysedge script to start the agent automatically at system boot time Copy this script from the config subdirectory to etc init d and then create a symbolic link to the file by entering the following command ln s etc re d init d sysedge etc rc d rc2 d S99sysedge If you installed the agent in a directory other than the default opt EMPsysedge you must edit the sysedge script to include the correct installation directory If you installed the agent s three configuration files sysedge lic sysedge cf and sysedge mon in a directory other than the default etc you must also edit sysedge to include the correct directory for these files NOTE If you are not using the directory structure that the Red Hat Linux distribution uses you must edit the commands for starting the agent to match the directory structure for the distribution you are using To run the SystemEDGE agent instead of the native Linux agent edit etc rc d init d snmpd by entering an exit 0 command before any of the snmpd script s code Starting the Agent Automatically for AIX Systems eHealth SystemEDGE User Guide To start the agent automatically for AIX systems you must add the comman
170. S gt 300 active 0x0 eHealth SystemEDGE User Guide 498 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Monitoring File Systems eHealth SystemEDGE User Guide The following entry in the sysedge mon file instructs the SystemEDGE agent to monitor how full the file system is every 2 minutes 120 seconds If the file system becomes 95 full the agent sends an SNMP trap message monentry 19 Monitor filesystem 120 a absolutevalu ied Oe dhe ced eS Owl eLa hg Teleka ge 23 active 0x0 NOTE The object instance identifier for the SystemEDGE agent may not be the same across all instantiations of the agent Adding Process Monitor Table Entries to the sysedge mon File 499 Adding Process Monitor Table Entries to the sysedge mon File Process Monitor table entries begin with the keyword processmon They are delineated by open and closed brackets and include eleven fields Table 87 describes the fields for Process Monitor table entries in the sysedge mon file Table 87 Fields for Process Monitor Table Entries Page 1 of 3 Beginning of the entry is marked by an open bracket pmonIndex Integer 1 to MAXINT that indicates the row index for this entry The index is particularly important because SNMP does not directly support creation and deletion of MIB objects instead it creates and deletes them as side effects of SNMP Set operations This limitation means that the person creating or
171. SE sysmgmt VARIABLES sysedgeLicenseString DESCRIPTION This Trap is sent when SystemEDGE or associated modules failed to find a valid license It can be used in conjunction with auto licensing or remote licensing starting with SystemEDGE 4 0 This Trap contains a single MIB object denoting which product or module failed to find a valid license and a string containing the license information for that product or module 16 eHealth SystemEDGE User Guide 228 e Chapter 8 Private Enterprise Traps addrChangeTrap eHealth SystemEDGE User Guide The following code shows the format of an addrChange trap which the SystemEDGE agent sends to indicate that the underlying IP address has changed addrChangeEvent OBJECT IDENTIFIER traps 18 addrChangeTrap TRAP TYPE ENTERPRISE sysmgmt VARIABLES nodename sysedgeAddressList DESCRIPTION This Trap is sent when SystemEDGE detects that its underlying IP address has changed perhaps due to DHCP or other administrative means It includes up to the last 5 IP addresses that this system was configured with The addresses are ordered with most recently used addresses occurring first in the address list This Trap may be used on multi homed systems 18 Format of Trap PDUs 229 procGroupChangeTrap The following code shows the format of a procGroupChange trap which the SystemEDGE agent sends to indicate that the process group has changed procGroupChang
172. Solaris 2 x the SystemEDGE agent needs access to the dev ip file and the udp Streams module in order to properly support MIB II Verify that the dev ip file exists and that it is readable by the SystemEDGE agent This problem can occur if you are running the SystemEDGE agent as a user other than the root user to read ioconfig magic Upon startup the SystemEDGE agent attempts to discover the devices that are contained in the underlying system using whatever operating system support is available This error message indicates the SystemEDGE agent could not properly read the HP UX etc ioconfig file and will therefore attempt to discover devices without the operating system s help to read monitor file The SystemEDGE agent failed to open either the default monitor file or the file that you specified on the UNIX command line The default monitor file f or UNIX is etc sysedge mon for Windows it is SystemROOt system32 sysedge mon to reload utmp cache The SystemEDGE agent failed to reload its internal table of users who are currently logged in to the system The SystemEDGE agent will continue function normally but may be unable to answer SNMP queries of Who Table objects SystemEDGE Agent Error Messages 453 failed to rename mon file The SystemEDGE agent periodically writes its in memory monitor table to the sysedge mon file Before doing so the SystemEDGE agent renames the current sysedge mon to sysedge old in the sa
173. Status textual convention For more information refer to Appendix E Setting the status to destroy 6 causes the agent to discontinue history sampling for this entry and to delete both this row and the corresponding data sample rows in the empireHistoryTable End of the entry is marked by a closed bracket Sample History Control Table Entries in sysedge mon This section includes an example for adding an entry to the History Control table through the sysedge mon file Disk Transfer History The following entry instructs the SystemEDGE agent to collect the disk transfer statistics for the first physical disk This is entry index 10 It will keep 100 samples and take a new sample every 60 seconds history 10 Disk 1 Transfers 100 ie Oak ore SO ol Ay dels Gis 60 active eHealth SystemEDGE User Guide Textual Conventions for Row Status This appendix provides information on the SNMPv2 textual conventions for row status This entire appendix is directly excerpted from RFC 1443 Textual Conventions for SNMPv2 Case et al 1993 RFC 1443 Textual Conventions for SNMPv2 RowStatus TEXTUAL CONVENTION STATUS current DESCRIPTION The RowStatus textual convention is used to manage the creation and deletion of conceptual rows and is used as the value of the SYNTAX clause for the status column of a conceptual row as described in Section 7 7 1 of 2 The status column has six defined values e active
174. SystemEDGE agent has permission to read it This SystemEDGE Agent Error Messages 449 problem can occur if you are running the SystemEDGE agent as a user other than the root user If you do not correct this error the SystemEDGE agent will continue to operate but will not be able to support the Host Resources Installed Software table failed to open var adm sw products On HP UX systems the SystemEDGE agent failed to open the var adm sw products directory for inspection of locally installed software packages Verify that the var adm sw products directory exists and that the SystemEDGE agent has permission to read it This problem can occur if you are running the SystemEDGE agent as a user other than the root user If you do not correct this error the SystemEDGE agent will continue to operate but will not be able to support the Host Resources Installed Software table failed to open var sadm patch On Solaris 2 x systems the SystemEDGE agent failed to open the var sadm patch directory for inspection of locally installed patches Check that the var sadm patch directory exists and that the SystemEDGE agent has permission to read it This problem can occur if you are running the SystemEDGE agent as a user other than the root user If you do not correct this error the SystemEDGE agent will continue to operate but will not be able to determine which patches have been installed on the underlying system failed to open var sadm pkg
175. UNIX a product kit as a group of related and Tru64 is formatted as a product kit This distribution uses file subsets the setld utility to install the SystemEDGE agent package eHealth SystemEDGE User Guide By default the distribution places the software in the usr opt EMPsysedge directory When you run the installation script you must enter valid values for all prompts If you enter invalid values or press Enter at a prompt that requires a value and does not offer a default value the script will not complete properly If the script generates an error message or is unable to complete you must run the script again and specify valid values for all prompts Installing SystemEDGE on Digital UNIX and Tru64 Systems 85 To install the software 1 3 Log in as root by entering su and then the root password at the password prompt Insert the CD containing the software distributions into the CD ROM drive and mount it using the following command assuming that your CD ROM drive is at SCSI address 0 mount r t cdfs dev rz0c cdrom Run the setld utility by entering the following commands one at a time cd cdrom sysedge tru64 cp sysedge tar tmp cd tmp tar xvof sysedge tar usr sbin setld 1 tmp EMPSYSEDGE Run the installation script by entering the following commands cd usr opt EMPsysedge Install The installation script displays the following message Concord SystemEDGE Agent post installa
176. Unmounting a Mounted Device 00 0 e eee 168 Kernel Configuration 0 cece cee eee eee enes 168 Boot CONMSUPANON os 402264 o40Gaent eee eeddsees cas tea es 169 Seams GlrOUD 6 36 seene a E E tek eeueas 170 User TM ormatON acaceagsccacn Sennteueeesdes oateonaacey 172 Group Information 0 cece eee eee eee ee ren 173 Process Information cine eo eeteqe ooee pew ed eg ed neepinedes 174 Changing the nice Value of a Process UNIX only 175 Sending a Signal to a Process 0 cece eee eee eens 176 Who Table Information si 2ec ceareiacec anced nsd ee eae 176 Remote Command Execution 002 e eee eee eee 177 Executing a Remote Command 0 e eee 178 eHealth SystemEDGE User Guide 8 Table of Contents Kernel Performance StaustcS c2 52i6 0keeea eect ddeidasss 178 Interprocess Communication Queues Shared Memory and Seid PROPS t 5 c0t ccd neces see eeuates oak sone gad oe 180 Deleting an Interprocess Communication 181 Message Buffer Allocation and Usage Statistics 182 neam BOU IS oy sae uusescaee dee secur abee E eossaenes 183 VO Daner Cache 4 cana evaecincekedsadhaus aiaee as 184 REG ClOUO ccs cacesee ee boegest se eceuwes beeeeravecenenes 185 IND SNGlOUD e saiec e425 So5 8 Seas oats eae ba eae ee aes ons ons 186 Windows Specific Groups 0 cece eee cece e eee eees 188 INT System GiOU pwc cneetee arn ateees tate aeaciawneeeas 188 NT Thre
177. X http www hp com Microsoft System Management http www microsoft com Server SMS Symantec Ghost http www symantec com PowerQuest Drive Image http www powerquest com Red Hat Kick Start http www redhat com eHealth SystemEDGE User Guide Automating Deployment 417 Table 82 lists some recommended software deployment tools Table 82 Recommended Software Deployment Tools Deployment Tool URL Computer Associates CA http www ca com Microsoft System Management http www microsoft com Server SMS HPOV Software Distributor http www hp com openview products softdist html Even if you choose not to implement a software distribution system you can take some steps to help automate deployment of the SystemEDGE agent in a distributed environment Automating Deployment Automating software deployment involves four steps Making software available to remote systems Installing software on remote systems Configuring software for distributed systems r 2 eS Licensing the software remotely Making Software Available to Remote Systems You can make software available to remote systems in a variety of ways including through protocols remote file systems and e mail Using Protocols to Distribute Software This section discusses the protocols that you can use to distribute software eHealth SystemEDGE User Guide 418 e Chapter 18 Deploying the SystemEDGE Agent eHealth Syst
178. a third party deployment system is recommended for a large preinstalled base You can also use the operating system specific installation packages that are included with the distribution CD and copy the required files Configuring Software for Distributed Systems The AdvantEDGE View interface enables configuration of individual agents or groups of agents For more information refer to the AdvantEDGE View Web Help You can configure software for a larger distributed system in several ways but in all cases it is desirable to accomplish this remotely You can generate a cookie cutter configuration file that can be used by all systems or classes of systems for example all Windows NT 4 0 machines or all UltraSPARC systems and then use scripts to copy specific configuration data to remote systems or include these configuration files with the SystemEDGE files when using third party deployment tools You can also update the SystemEDGE configuration file remotely through SNMP Set commands This allows programs like AdvantEDGE View eHealth HP OpenView and other SNMP compliant software to configure the SystemEDGE agent remotely eHealth SystemEDGE User Guide 420 e Chapter 18 Deploying the SystemEDGE Agent Licensing Software Remotely Automated remote licensing of the SystemEDGE agent is available through the AdvantEDGE View interface For more information refer to Chapter 3 Licensing the SystemEDGE Agent and to the AdvantED
179. a value and does not offer a default value the script will not complete properly If the script generates an error message or is unable to complete you must run i NOTE the script again and specify valid values for all prompts For each prompt the default value is shown in brackets You can press Return to accept the default or you can enter another value and then press Return installation script also enables automatic licensing of the agent For information about additional ways to license the agent refer to Chapter 3 Licensing the SystemEDGE c 99D Agent 4 Disable the native SNMP agent if desired by pressing Return at the following prompt Disable the native SNMP Agent if applicable yes eHealth SystemEDGE User Guide 54 e Chapter 2 Installing the SystemEDGE Agent For more information about running multiple SNMP agents simultaneously refer to Chapter 6 Using the SystemEDGE Agent with Other SNMP Agents 5 Configure the SystemEDGE agent to use UDP port 1691 if you are running another SNMP agent on port 161 by entering y at the following prompt Change SystemEDGE port to 1691 default is 161 yes NOTE You must perform this step if you did not disable the native SNMP agent in the previous step 6 Press Return at the following prompt if you want to enter a description for your system Configure system description yes a Enter the system description for example Te
180. able Figure 18 Systems Management MIB Sample Log Monitor Table For more information about configuring SystemEDGE log file monitoring refer to Chapter 13 Configuring Log File Monitoring The SystemEDGE agent can track the values of various integer based MIB objects counters gauges and so on over time and store them for later retrieval This functionality commonly referred to as history sampling can greatly reduce the amount of management station polling across the network The agent provides this functionality through two SNMP MIB tables e History Control table e History table The History Control table contains parameters that describe the data that will be sampled and stored in the History table Each row in the control table defines a specific data collection function by assigning values to the parameters column objects of the table One or more rows stored samples in the History table are associated with that single control row eHealth SystemEDGE User Guide 206 e Chapter 7 Systems Management MIB Each control table row is assigned a unique index value empireHistoryCtrlIndex A row defines the data collection function by specifying the object instance to be sampled how often to sample in multiples of 30 seconds and the number of samples to keep buckets Associated with each data collection function row of the control table is a set of rows of the History table Each row of the History table also cal
181. acility refer to the following man pages for more information on the syslog facility e syslog 3 e syslog conf 5 e syslogd 8 You can also edit the sysedge cf file to instruct the SystemEDGE agent to log these messages in a different facility For instructions refer to Configuring Alternative Syslog Facilities UNIX Only on page 134 Logging syslog Messages syslog messages are typically logged to the var adm messages or usr adm syslog text file depending on your system and how the syslog daemon is configured on that system By default the SystemEDGE agent daemon uses syslog to log messages with priority levels of informational through emergency If you are running the agent in debug mode with the runtime command line option d syslog will also log messages of the debug priority level 489 490 e Appendix B Using the syslog Facility eHealth SystemEDGE User Guide This guide does not provide a complete tutorial on the syslog utility Instead it describes how to configure the syslog daemon on your system to log messages from daemon processes like the SystemEDGE agent to a text file var log daemon log for Sun SPARC systems and usr adm daemon log for HP UX systems Every message that is sent using syslog includes a facility code that tells where the message is coming from and a priority code that tells the severity of the message Table 84 describes the available syslog facility codes Table 84 syslog Faci
182. ad OU0G ems cene eee saseeeeuets suena sence 190 NT Resistty GOUD 055440000 fare ewew chi eet cay ws 191 INT Service OOU Pescar ereire e vee ce heageeas 192 NT System Performance Group e secu eeee 193 NT Cache Performance Group cece ences 194 NT Memory Performance Group 2 0000 195 NT Page File Performance Group 2 0000 197 NT Event Monitor Group 2 ce eee eee teens 197 NT Registry and Performance Extension Group 199 Unsupported MIB Objects on Windows 4 199 Monitor Table o2aucrsecencapeceaaseecsdotereencowseses 202 Process Monitor labl cc s20a 00cctcasnaokeennseahsadens 203 Process Group Monitor Table 0 0 cece eee eee ee 203 LOS MONO Tables cccetceensene shen6 N a 204 History TAD ICs seiancare eae gta eee E sew ones aaa eer eres 205 History Sampling Examples 0 cece eeee 206 Disk Statistics GrOUD is bere sserexseeedesarwesevoucocs 208 Enabling Collection of Disk Performance Statistics 209 CPU Statistics GlOUDP ere tee reed ierte ain aT 211 Extension GroUpP 4445046 lt as ond4cau kiai tina idiiaias ias 212 eHealth SystemEDGE User Guide Chapter 8 Chapter 9 Table of Contents e 9 Private Enterprise Traps 215 Formator Trip POU S eiss ceeccesreotieads cee ee donis adti 215 MIONMOL LID s6245044550646404 pentinar E ea 216 monitorEntryNotReady Trap 0 cece eee eee 217 logMonMatch Trap c
183. ad Write Process attribute that is being monitored For a complete list of supported attributes refer to Table 38 on page 288 For example to monitor a process to ensure that it is alive specify the procAlive attribute To track the number of packets received by the particular application or process specify procMsgsSent eHealth SystemEDGE User Guide The Process Monitor Table 285 Table 37 Columns of the Process Monitor Table Page 2 of 4 Column Name Permissions Description a pemes Only Attribute value that was last recorded for the process that is being monitored Every pmonInterval seconds the agent updates this field to reflect the latest reading for the attribute When monitoring procAlive this value is mapped from the hrSWRunStatus variable of the Host Resources MIB Possible values follow e 0 The row is not ready If this is the case the PID value will be 1 1 The process is running 2 The process is waiting for a resource CPU memory or I O 3 The process is not runnable It is waiting for an event 4 Invalid The process is not loaded pmonOperator Read Write Operator type A boolean operator used for evaluating the following expression current value operator value The operator can be one of the following nop no operation monitor the object s value but do not evaluate the Boolean expression gt greater than lt less than gt greater than or equal to lt less than
184. age writes e Many other memory and paging related statistics For more information about the specific MIB objects refer to the empire asn1 file in the doc subdirectory of the SystemEDGE agent distribution Figure 14 shows the organization of the NT Memory Performance Group ntSystemPerf lt 1 ntAvailkBytes 1 g ntCachePerf lt 2 ntCachekBytes 2 f ntCachekBytesPeak 3 ntCacheFaults 4 gt ntCommitLimit i5 ntCommittedKBytes 6 ntDemandZeroFaults 7 ntFreeSysPagelT ableEntries 8 ntPageFaults 9 ntPageReads 10 ntPageWrites 11 ntPagesInput 12 ntPagesOuput 13 ntMemoryPerf 3 ntPageFilePerf 4 monitorEntry 1 ntPages 14 gt ntPoolNonPagedAllocs 15 ntPoolNonPagedkKBytes 16 ntPoolPagedAllocs 17 ntPoolPagedkKBytes 18 a a ANN empireHistoryEntry 1 logMonitorEntry 1 Figure 14 NT Memory Performance Group ntPagedResidentkKBytes 19 gt e ntSysCodeResidentkKBytes 21 ntSysCodeTotalKBytes 22 ntSysDriverResidentkKBytes 23 Windows Specific Groups 197 NT Page File Performance Group Windows uses the Pagefile sys paging file to handle any extra demands for memory The paging file is a block of disk space reserved by the operating system so that the memory manager can free space in memory when necessary It does so by writing pages that are not often referenced to the paging file that is on disk You can monitor the size of the paging file to determine wheth
185. agent to send a maximum of x consecutive traps when this monitor expression evaluates to True Specifies that x 5 That is the agents sends 5 consecutive monitorEvent traps and then stops sending traps until the entry resets itself The entry resets itself when the expression transitions from True to False Does not specify that the agent should send monitorClear traps consequently a monitorClear trap is not sent when the expression transitions from True to False e 60 indicates that the interrupt rate should be sampled every 60 seconds e delta tells the agent to measure the rate at which the number of interrupts has changed Because this object is a counter delta is an appropriate sample type eHealth SystemEDGE User Guide 268 e Chapter 10 Configuring Threshold Monitoring e 1000 is the value against which the current number of interrupts is compared e indicates that no action is specified Figure 36 shows how the agent would send and clear traps based on this monitor directive 2ample Trap Sent Sample No Trap Sent E sample Clear Trap Sent Flags Ox00500400 Value _ Threshold Tire Figure 36 Monitoring the System s Interrupt Rate Monitoring the System s Page Fault Rate The following example configures the SystemEDGE agent to monitor the rate at which hardware page interrupts are occurring on the local system monitor oid numPageFaults 0 15 0x00500500 60 delta gt 1000
186. agents it instructs the SystemEDGE agent to use port UDP 1691 4 Restart the SEA multiplexor by entering the following commands etc rc2 d K76snmpdx stop etc rce2 d K76snmpdx start NOTE Although the SEA multiplexes SNMP Get GetNext and Set operations it does not correctly support SNMP row creation operations across subagents because they occur as side effects of Set operations on non existent rows Consequently when you are using utilities such as edgewatch edgemon and emphistory to create rows in their respective SNMP tables query the SystemEDGE agent directly not the SEA master agent You can instruct those utilities to query UDP port 1691 by appending 1691 to the hostname or IP address when you invoke the utilities Using the SystemEDGE Agent with the Microsoft Windows SNMP Agent The Microsoft Windows SNMP Agent is a master agent that multiplexes among subagents that are linked into its address space at run time Subagents are implemented as Windows DLLs Upon initialization the Microsoft master agent utilizes registry settings to determine which subagents and corresponding DLLs to load Upon initialization the subagents inform the Master agent which MIB branches they implement eHealth SystemEDGE User Guide 162 e Chapter 6 Using the SystemEDGE Agent with Other SNMP Agents In Release 4 2 the SystemEDGE agent is no longer a subagent of the Microsoft SNMP agent It can coexist with the Microsoft Windows exte
187. ains how to send a signal to a process To send a signal to a process 1 Find the row that represents the selected process 2 Set the processKill column in that row to the number corresponding to the desired signal For more information refer to the UNIX signal 3V man page Who Table Information eHealth SystemEDGE User Guide Use the Who table to find out which users are currently logged on to the host system Each row in this table represents a current user and contains columns that represents the following e User s name e Login device e Login PID e Login time Location from where the user is logged in The Who table can help you monitor who is using this system at a particular time NOTE Depending on your local security policies you may want to disable support for this table For more information about disabling this support refer to Configuring Support for Who Table Information on page 132 Figure 8 shows a sample Who table which lists the users who are currently logged on Remote Command Execution 177 e SNMP Table Display Table whoTable Path 1 3 6 1 4 1 546 1 1 5 1 Rows 9 Columne 6 Instance wholndex whohame wholevice whoFID whol ime whoWhere 0 cheryl console Od 21 50 45 1 1 cheryl ttypl 8 Od 21 50 45 10 0 z 2 cheryl ttupe fs Od 21 50 45 10 0 a a cheryl ttyp fs Od 21 50 26 10 0 4 4 rdk ttyp4 fs d 18 50 55 ottomanso 0 5 5 cheryl ttuyph fs Od 18 26 46 10 0 E E
188. allShield version as described in Uninstalling an Agent with InstallShield on page 99 and then reinstall from the command line To install the software Log on to the Windows system as administrator Insert the CD that contains the software distributions into the CD ROM drive Windows automatically mounts the drive using the CD ROM drive s corresponding drive letter Change to the sysedge win directory and double click sysedge exe to run the InstallShield program The following dialog box appears to recommend turning off any anti virus programs currently running d 1 Some antivirus services will interfere with installation of SystemEDGSE Concord recommends that resident antivirus services be disabled until after the installation is complete eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 61 4 After disabling your antivirus program click OK The following dialog box appears InstallShield Wizard Pe xj Concord SystemEDGE Installation SystemE DGE ts an extensible SNMP agent for managing critical UNI or NT systems and applications Special support is available for Exchange Sendmail Oracle SOL Server S Apache amp more See Athos aa concord com spsedge Cancel NOTE If you are upgrading the SystemEDGE agent the SystemEDGE Maintenance dialog box appears Select Modify and then click OK After the program updates the agent click Finish 5 Click N
189. and even the number of systems that are managed The unique self monitoring capability of the SystemEDGE agent is specifically designed to provide the kind of management by exception that is necessary in distributed network environments The SystemEDGE agent provides the following types of monitoring Threshold monitoring e Process and service monitoring e Process group monitoring Log file monitoring e Windows event monitoring e History collection Threshold Monitoring The SystemEDGE agent can monitor exception conditions automatically reducing or eliminating the need for constant polling by an network management system NMS You can configure the agent s flexible Monitor table to monitor any integer based MIB object that the agent supports You set the polling interval comparison operator greater than equal to and so on and threshold value and SystemEDGE automatically monitors the MIB objects that you specify You can tailor entries for time over threshold to reduce noise SystemEDGE can also send traps to an NMS if exceptions occur eHealth SystemEDGE User Guide 32 e Chapter 1 Introduction eHealth SystemEDGE User Guide For example you can configure SystemEDGE to monitor the available space on a particular file system and to notify the NMS when the file system becomes too full For more information refer to Chapter 10 Configuring Threshold Monitoring Process and Service Monitoring With Sys
190. and performance variables 408 Index e 531 copying sysedge cf 119 countmail sh 96 CPU Statistics group 211 creating log file for daemon messages 491 D daemon messages logging 491 debugext sh 399 debugging SystemEDGE agent 135 deleting entries History Control table 389 Log Monitor table 349 Monitor table 275 Process Group Monitor table 332 Process Monitor table 311 interprocess communication 181 deploying SystemEDGE agent 413 diagsysedge exe 94 423 426 Digital UNIX installing SystemEDGE 84 platform support 23 removing SystemEDGE 103 SNMP agent 163 system requirements 84 disabling automatic reinitialization of agent 291 entries History Control table 389 Log Monitor table 349 NT Event Monitor table 376 event logging 291 support for remote file system checking 138 disk performance statistics enabling on Windows 208 probing configuring support 136 eHealth SystemEDGE User Guide 532 ndex Disk Statistics group 208 Disk Storage Table 239 distributing software through protocols 417 documentation conventions 25 dynamic configuration History Control table 386 Log Monitor table 345 Monitor table 261 NT Event Monitor table 369 Process Group Monitor table 328 Process Monitor table 299 E edgemon utility directory 90 error messages 472 overview 274 removing entries Log Monitor table 350 Monitor table 279 NT Event Monitor table 377 Process Group Monitor table 332 Process Monitor table 316 edgem
191. ap TRAP TYPE ENTERPRISE sysmgmt VARIABLES monDescr monOlD monCurrVal monValue monRowStatus monOperator monIndex monFlags DESCRIPTION This trap is sent when a Monitor Table entry transitions from True to False and is using a clear trap flag This trap indicates that the condition that previously had existed no longer does This Trap provides management software the ability to determine that an alarm can be canceled or marked as corrected This event only occurs when a monitor table entry evaluates to True and then evaluates to False This Trap is sent each time the entry transitions from True to false Format of Trap PDUs 223 processstop Trap The following code shows the format of a processStop trap which the SystemEDGE agent sends to indicate that a process it was monitoring has either stopped running or is in a state where it cannot run processStopEvent OBJECT IDENTIFIER traps 10 processocopl rap TRAP TYPE ENTERPRISE sysmgmt VARIABLES pmonIndex pmonDescr pmonAttribute pmonCurrVal pmonOperator pmonValue pmonFlags pmonRegExpr pmonCurrentPID DESCRIPTION This Trap is sent when using a Process Monitor Table entry to monitor the state of a process When the processing being monitored dies or transitions into a Zombie or not runnable state this Trap is sent This Trap is sent if the value of pmonFlags does not preclude sending Traps s 10 eHealth SystemEDGE User Guide 224 e Chapt
192. aps 5 logMonNotReadyTrap TRAP TYPE ENTERPRISE empire VARIABLES lLogMonitorLogFile logMonitorRegularExpression logMonitorLastTrap logMonitorLastMatch logMonitorDescr logMonitorIndex logMonitorFlags DESCRIPTION This trap is sent when the status of a log monitoring entry becomes notReady 3 An entry becomes notReady 3 if an error occurs during log file scanning if the regular expression is syntactically incorrect or if the log file does not exist An entry that is notReady 3 will undergo no further evaluation until its status becomes active 1 eHealth SystemEDGE User Guide 220 e Chapter 8 Private Enterprise Traps ntEventMonMatch Trap eHealth SystemEDGE User Guide The following code shows the format of an ntEventMonMatch trap which the SystemEDGE agent sends to indicate that the event log monitoring subsystem has detected a match in a Windows event log file that the agent is currently monitoring ntEventMonMatchEvent OBJECT IDENTIFIER traps 7 ntEventMonMatchTrap TRAP TYPE ENTERPRISE empire VARIABLES ntEventMonLog ntEventMonTypeLastMatch ntEventMonTime ntEventMonSrcLastMatch ntKventMonDescLastMatch ntEventMonDescr ntEventMonIndex ntEventMonFlags DESCRIPTION This trap is sent when the event log monitoring subsystem detects a match in a log it is currently monitoring Periodically the agent checks each event log for changes if any changes have occurred the agent scans on
193. atch process procAlive E E E E E E E HEE EE EH H EH H HHE H H Service i netscape NETSCAPE C sysedge contrib restartproc bat netscape NETSCAPE nha Server 50 0x8 30 eH Nhi Server nhiMsgServer 51 0x8 30 eH Message Server nhiLiveExSvr 52 0x8 30 eH LiveEx Server nhiDbsServer 53 0x8 30 6h Db Server m nhiCfgServer 54 0x8 30 ten Cfg Server nn hepa 55 Oxo 30 eh HELPA Server ti fmhiPoller 56 0x8 30 eh Poller inetinfo INETINFO 400 0x8 30 MS IIS T dsamain DSAMAIN 401 0x8 60 emsmta EMSMTA imc IMC 403 store STORE mad MAD 405 events EVENTS sqlservr SQLSERVR sqlexec SQLEXEC services SERVICES Alerter Browser Messenger EventLog Service dbabrd DBABRD 412 0x8 60 dbasvr DBASVR msdtc MSDTC lsass LSASS ROC De RE Coo eHealth SystemEDGE User Guide Chapter 4 Configuring the SystemEDGE Agent 0x8 60 404 0x8 60 Ox8 30 414 0x8 60 415 0x8 60 416 0x8 60 L 0x8 60 402 0x8 60 407 0x8 30 408 0x8 60 413 0x8 60 MS Exchange MTA Netscape Alive MS Exchange Internet Mail 2 0x200508 60 absolute gt 50000 MS Exchange Directory MS Exchange Info Store 409 0x8 60 Backup Agent MSDTC Service Net Logon MS Exchange Attendent 406 0x8 30 MS Exchange Event MS SOL Server Remote Procedure Call SOL Executive Service Backu
194. atically at boot time If you did not disable the native SNMP agent during the installation you can do so by editing snmpd in sbin init d and putting an exit 0 statement before any of the snmpd script s code eHealth SystemEDGE User Guide 96 e Chapter 2 Installing the SystemEDGE Agent Table 9 Directories and Files for All Platforms Page 3 of 4 Directory File Description config sysedge Linux Only Shell script for starting and stopping the agent If you disabled the native SNMP agent through the installation process the installation script places this script in etc rc d init d and link etc rc d rc2 d S99sysedge to it to start the agent automatically at boot time If you did not disable the native SNMP agent during the installation you can do so by editing snmpd in etc init d and putting an exit 0 statement before any of the snmpd script s code continued contrib Subdirectory that contains the SystemEDGE agent dynamic link library command line utilities for use with SystemEDGE self monitoring and sample extension and action scripts auto install Sample scripts which automate the installation deployment and licensing of the SystemEDGE agent distribution call sendtrap c Sample C code to call the sendtrap utility from within a program checkprinter exe Sample extension script for checking the printer status on Windows systems countmail sh Sample script that measures the mail message throughput of the S
195. bject instance to monitor in this case the object instance is devlableEntry devCapacity from the Systems Management MIB devTable The object instance is not specified because it is determined automatically based on the name of the file system 20 indicates that this entry is row 20 of the Monitor table 120 indicates that the agent should sample every 120 seconds Threshold Monitoring Examples 273 e absolute is the appropriate sample type because the agent is sampling an integer value that represents how full the file system is e 95 specifies the value to use in the comparison If the file system becomes greater than gt 95 full the agent sends a trap message to all configured managers e indicates that no action is specified The flags field of 0x00100500 specifies several things Itconfigures the agent to send monitorClear traps when the expression transitions from True to False It specifies that the agent should send at most x consecutive monitorEvent traps and then send no more until the entry resets itself It specifies x 1 which indicates that the agent should send only one monitorEvent trap before waiting for the entry to reset itself Figure 38 shows how the agent would send and clear traps based on this monitor directive Sample Trap Sent ample No Trap Sent E Sample Clear Trap Sent Flags 0x00100500 Value Threshold Figure 38 Monitoring Space on the usr Fil
196. ble 323 Table 46 Columns of the Process Group Monitor Table Page 4 of 4 Column Name Permissions _ Description Coane Only Total percentage of real memory that is being used by the processes in this group The percentage of memory being used is summed at each interval and stored in this MIB variable Memory usage includes shared memory shared libraries and DLLs so the total percentage may exceed 100 Number of Number of system calls invoked by processes in this group calls invoked Number of system calls invoked by processes in this group processes in this group pgmonMinorPgFlts Read Only Number of minor page faults incurred by processes in this group pgmonMajorPgFlts Read Only Number of major page faults incurred by processes in this group pgmonNumSwaps Read Only Number of times processes in this Number of times processes in this group have been swapped have been Number of times processes in this group have been swapped pgmonVolCtx Read Only Number of voluntary context switches incurred by processes in this group pgmonInvolCtx Read Only Number of involuntary context switches incurred by processes in this group pgmonCPUSecs Read Only Number of seconds of CPU time used by processes in this group pgmonMatchUser Read Write When this object is set to a valid user name SystemEDGE matches running processes by user name as well as any process name regular expression This variable is valid only on U
197. cess Consequently you can monitor Windows services in two ways e Monitor Windows services by monitoring their underlying processes It is not always easy to figure out the underlying process within which a service is running In this case you can have the SystemEDGE agent monitor the service itself rather than the underlying process Instruct the SystemEDGE agent to monitor the Windows service rather than the underlying process by setting a flag or by using the configuration keyword watch ntservice For more information about Process Monitor table flags refer to Table 40 on page 291 NOTE Because Windows does not track process attributes for Windows services the SystemEDGE agent can monitor only the procAlive attribute for Windows services To monitor other attributes for example procRSS for a particular Windows service you must monitor the underlying process that implements that Windows service Sample Process Monitor Table Entry This section provides a sample Process Monitor table entry that instructs the SystemEDGE agent to monitor the httpd process to make sure it is up and running Index Description Interval SampType Attribute CurrVal Oper Value LastCall Traps LastTrap Flags RowStatus Action RegExpr 12 Monitor httpd 60 absoluteValue procAlive 3 gt 4 Od 22 40 00 0O 0 0x00000100 active me httpd This sample entry provides the following information e This entry is the 12th row in the Process Monitor table
198. ches 12 clientNFSWrites 13 clientNFSCreates 14 clientNFSRemoves 15 clientNFSRenames 16 clientNFSLinks 17 clientNFSSymlinks 18 clientNFSMkdirs 19 NFS Group 187 e clientNFSRmdirs 20 e clientNFSReaddirs 21 e clientNFSFsstats 22 e serverNFSCalls 23 e serverNFSBadcalls 24 e serverNFSNulls 25 e serverNFSGetattrs 26 e serverNFSSetattrs 27 e serverNFSRoots 28 e serverNFSLookups 29 e serverNFSReadlinks 30 e serverNFSReads 31 e serverNFSWrcaches 32 e serverNFSWrites 33 e serverNFSCreates 34 e serverNFSRemoves 35 e serverNFSRenames 36 e serverNFSLinks 37 e serverNFSSymlinks 38 e serverNFSMkdirs 39 e serverNFSRmdirs 40 e serverNFSReaddirs 41 e serverNFSFsstats 42 For descriptions of these MIB objects refer to the empire asn1 file in the doc subdirectory of the SystemEDGE agent distribution eHealth SystemEDGE User Guide 188 e Chapter 7 Systems Management MIB Windows Specific Groups In most cases the SystemEDGE agent supports the same MIB objects for Windows and UNIX However the underlying Windows operating system does not support some of the MIB objects and therefore cannot be implemented by the SystemEDGE agent for Windows For a list of the MIB objects that are not supported by these Windows operating systems refer to Unsupported MIB Objects on Windows on page 199 The following sections define groups that have been specifically designed for Windows systems including Windo
199. d in some respects are transmitted in clear text in SNMP PDUs Consequently community names can be vulnerable to packet snooping Communities have read only or read write permissions associated with them which allow the inspection of or inspection alteration of MIB variables respectively The SystemEDGE agent can attach IP address based access control lists to communities but IP spoofing can circumvent them For more information refer to Configuring Access Communities on page 128 Security Issues with Extension Variables and Action Commands Because the SystemEDGE agent runs as root or administrator you must be careful when using extension variables and action commands More specifically you should take steps to ensure that all commands and scripts use absolute pathnames are fully debugged and contain no ambiguous code or unnecessary options You can also specify that the agent run all subprograms for example actions extension objects and so on as with users and groups other than root For more information about configuring user and group permissions for sub programs refer to Configuring User Group Permissions for Subprograms UNIX Only on page 142 For more information about using extension variables refer to Chapter 16 Adding Custom MIB Objects For more information about actions that you can use with the SystemEDGE agent refer to Chapter 10 Configuring Threshold Monitoring and Chapter 13 Configur
200. d Average 497 Monitoring File Systems 0 eee cece ee eee ee 498 Adding Process Monitor Table Entries to the sysedge mon File 499 Sample Process Monitor Entries in sysedge mon 501 Monitoring the Netscape Process Run Status 502 Monitoring the Netscape Process Size 2 4 502 Adding Process Group Monitor Table Entries to the SyseCee MOn Piles satagetunce cs KASEDA ER ECER E E nee 503 Sample Process Group Monitor Entry in sysedge mon 505 Monitoring the httpd Process Group 005 505 Adding Log Monitor Table Entries to the edee lon File sessioner te una aeacoean EEREN 506 Sample Log Monitor Entry in sysedge mon 507 Monitoring for Failed su Attempts 04 507 Adding NT Event Monitor Table Entries to the sysedge mon File 25202405 acedorsionsorigecdeeciwet satinu 508 Sample NT Event Monitor Entries in sysedge mon 510 Monitoring for Application Errors 00005 510 Adding History Control Table Entries to the sysedge mon File 511 Sample History Control Table Entries in sysedge mon 512 Disk Transler History sosed ssionataap ideni REENE 512 Textual Conventions for Row Status 913 RFC 1443 Textual Conventions for SNMPv2 513 Conceptual Row Creation 0 cece eee eee eee ees 516 Interaction 1 Selecting an Instance Identifier 516 Interaction 2 Creating the Conceptual Row
201. d above indicates that you are attempting to execute a SystemEDGE agent binary on an operating system release for which it is not compiled Common Problems and Questions e 431 To ensure that your system is executing the correct SystemEDGE agent binary examine the UNIX startup script to ensure that it is selecting the appropriate binary Table 83 lists the appropriate binaries for the software versions that this Release of the SystemEDGE agent supports Table 83 SystemEDGE Agent Binaries Page 1 of 2 Operating System Version SystemEDGE Agent Binary AIX 4 3 3 sysedge aix433 AIX 5 1 and 5 2 32 bit sysedge aix5 1 AIX 5 1 and 5 2 64 bit sysedge aix5 1 64 Digital UNIX 4 0F or 4 0G or sysedge du4 Tru64 5 1A sysedge du5 HP UX 11 0 and 11i 32 bit sysedge hpux 1 HP UX 11 0 11i and 11i v2 sysedge hpux1 1 64 64 bit Linux sysedge Solaris 2 6 sysedge sol26 Solaris 2 7 32 bit sysedge sol27 Solaris 2 7 64 bit sysedge sol27 sparcv9 Solaris 8 32 bit sysedge sol28 Solaris 8 64 bit sysedge sol8 sparcv8 Solaris 9 32 bit sysedge sol9 Solaris 9 64 bit sysedge sol9 sparcv9 eHealth SystemEDGE User Guide 432 e Chapter 19 Troubleshooting and Usage Suggestions eHealth SystemEDGE User Guide Table 83 SystemEDGE Agent Binaries Page 2 of 2 Operating System Version Solaris x86 2 7 32 bit Solaris x86 2 8 32 bit Solaris x86 2 9 32 bit Solaris x86 2 10 32 bit Windows NT 4 0 Windows 2000 Window
202. d devices 167 NES group 186 NT Cache Performance group 194 Event Monitor group 197 Memory Performance group 195 Page File Performance group 197 Registry and Performance Extension group 199 Registry group 191 Index 543 Service group 192 System group 188 System Performance group 193 Thread group 190 ntRegPerf group 403 overview 29 165 Process Monitor table 203 process table 174 remote command execution 177 RPC group 185 self monitoring tables 30 streams buffers 183 group 170 system information 166 unsupported MIB objects on Windows 199 user accounts 172 groups 173 logged on to system 176 Who Table 176 Windows specific groups 188 sysvariable utility directory 91 error messages 484 using 426 sysvariable exe 93 sysvariable txt 94 eHealth SystemEDGE User Guide 544 e I ndex T threshold monitoring examples 264 introduction 31 sample entry 246 Top Processes AIM configuring support 144 overview 33 tracking assets 34 trap communities configuring 130 overview 50 Trap PDU format 215 traps address changing 228 authentication failure 132 changing process group 229 enabling monitorClear traps 254 format 230 implementing severity levels 436 license 227 LogMonMatch 218 LogMonNotReady 219 monitorClear description 222 enabling 260 setting in Monitor table 254 monitorEntryNotReady 217 254 monitorEvent 216 ntEventMonMatch 220 ntEventMonNotReady 221 private enterprise 215 processClear
203. de Installing SystemEDGE on Linux Systems 81 Installing the Software The SystemEDGE agent for Linux is distributed as a tar file named sysedge tar This command requires the CD ROM to be located at dev cdrom and the mount directory to be cdrom For information about the locations of your CD ROM device and mount point refer to your Linux documentation To install the software 1 Log in as root by entering su and then the root password at the password prompt Create the home directory for the SystemEDGE agent by entering the following mkdir opt EMPsysedge NOTE The recommended default installation directory is opt EMPsysedge You can use another directory but the examples throughout this guide assume that you are installing the SystemEDGE agent in the opt EMPsysedge directory Insert the CD ROM containing the software distributions into the CD ROM drive and mount it with the following command mount rt iso9660 dev cdrom cdrom Change the directory to the agent s home directory and load the files from the CD ROM by entering the following commands one at a time cd opt EMPsysedge tar xvof cdrom sysedge linux sysedge tar eHealth SystemEDGE User Guide 82 e Chapter 2 Installing the SystemEDGE Agent When you run the installation 5 Start the installation script by running the installation script you must enter valid script from the directory where you installed SystemEDGE values for all pr
204. dependent OIDs to return the process state For more information refer to empire asn1 e For processes that run through an interpreter such as Perl set the 0x00000800 flag to match the process name and arguments UNIX only when creating process monitoring entries For more information refer to Table 40 on page 291 CPU time over interval if this value is not incrementing the process might be in the zombie state Total CPU time a value that is too high can indicate problems Leaking memory RSS over time use alarm thresholds to notify you of problems e Configure SystemEDGE to automatically restart failed processes e Set your UNIX application shutdown files to disable process and service monitoring to prevent race conditions e Use the Process Group Monitor table to monitor multiple processes with the same name For more information refer to Chapter 12 Configuring Process and Service Monitoring eHealth SystemEDGE User Guide For information about monitoring individual processes and Windows services refer to Chapter 11 Configuring Process and Service Monitoring Configuring Process Group Monitoring This chapter explains how to use the SystemEDGE agent to monitor groups of processes The agent uses process groups to ageregate the per process information into a single easy to poll easy to monitor value Monitoring Process Groups The flexible Process Group Monitor table of the
205. directive execv failed for action The SystemEDGE agent failed to exec the action command Exec failures can occur if the command is invalid if the binary or shell script no longer exists in the specified location or if the execute permissions are not properly set Check the action command for example by hand and if appropriate update the SystemEDGE agent configuration file sysedge cf execv failed for extension command The SystemEDGE agent failed to exec the extension command Exec failures can occur if the command is invalid if the binary or shell script no longer exists in the specified location or if the execute permissions are not properly set Check the extension command for example by hand and if appropriate update the SystemEDGE agent configuration file extension command file X is not a regular file The extension command file is not a valid executable or shell script Check the specified file and ensure that it is not a directory device and so on For more information about extending the SystemEDGE agent refer to Chapter 16 Adding Custom MIB Objects eHealth SystemEDGE User Guide 446 e Appendix A Error Messages extension filename too long The extension command file name is too long The SystemEDGE agent limits command file names to 256 characters Check the extension statement in the configuration file and restart the SystemEDGE agent For more information about extending the SystemEDGE agent re
206. dows systems it prevents logging events to the agent s log file sysedge log When events occur frequently it may be useful to disable event logging 0x00000020 Do not pass SystemEDGE arguments to action scripts or programs SystemEDGE normally passes default action parameters that indicate the trap type description field and so on This flag disables the passing of those arguments For more information refer to Process Group Monitor Table Actions on page 326 0x00000040 Do not send notReady traps for this entry 0x00000100 Match the process name and arguments for this entry Process Group Monitor Table Actions The SystemEDGE agent provides several default parameters to the action commands when they are invoked These parameters are in addition to any parameters that you specify in the action string and are passed on the command line after those that you eHealth SystemEDGE User Guide Viewing the Process Group Monitor Table with AdvantEDGE View 327 specify The default parameters are the same as the parameters provided in the SNMP traps that are sent for the Monitor table For more information about traps sent by the SystemEDGE agent refer to Chapter 8 Private Enterprise Traps Viewing the Process Group Monitor Table with AdvantEDGE View If you are using AdvantEDGE View you can query a system for Process Group Monitor table information by selecting the system you want to monitor from the System list selectin
207. ds for starting the agent to the local boot file etc rc tcpip To do so and to include the sysedge agent process enter the following usr lpp EMPsysedge bin sysedge b Logging Agent Operation Messages 155 When you enter this command you must include the full directory path and file name for sysedge on your system Starting the Agent Automatically for Digital UNIX or Tru64 Systems For Digital UNIX and Tru64 systems you must run the SystemEDGE agent s sysedge script to start the agent automatically at system boot time Copy this script from the config subdirectory to etc init d and then create a symbolic link to the file by entering the following command ln s sbin init d sysedge sbin rc3 d S99sysedge If you installed the agent in a directory other than the default usr opt EMPsysedge you must edit the sysedge script to include the correct installation directory If you installed the agent s three configuration files sysedge lic sysedge cf and sysedge mon in a directory other than the default etc you must also edit sysedge to include the correct directory for these files To run the SystemEDGE agent instead of the native Digital UNIX or Tru64 agent edit sbin init d snmpd by entering an exit 0 command before any of the snmpd script s code Logging Agent Operation Messages This section explains how to log agent operation messages Logging Messages for UNIX The SystemEDGE agent uses the UNIX syslog
208. e History Control Table and the Data Table eHealth SystemEDGE User Guide The History Control table contains parameters that describe the data that the agent will sample and store in the History table Each row of the History Control table assigns values to the parameters columnar objects of the table and thereby defines a specific data collection function One or more rows stored samples in the History table are associated with that single control row Each control table row is assigned a unique value of empireHistoryCtrlIndex A row defines the data collection function by specifying the object instance to be sampled how often to sample in multiples of 30 seconds and the number of samples to keep buckets Associated with each data collection History Control Table and the Data Table 381 function row of the control table is a set of rows of the History table Each row of the History table which is also called a bucket holds the value of the specified MIB object that was gathered during one sampling interval As each sampling interval occurs the agent adds a new row to the History table with the same empireHistoryIndex as the other rows for this data collection function Each new row corresponds to the single row in the History Control table and has an empireHistorySampleIndex that is one greater than the SampleIndex of the previous sample Columns of the History Control Table Table 70 describes the columns of the
209. e eHealth SystemEDGE User Guide Assigning Entry Rows for the Monitor Table 257 ret Last ii abel network absolute 9 49 days g 1 interfaces 1 isara nnauantaGsT sora agent CPU Load fra un 49 days 2 monitoring 60 0 00 00 0 lo 0x0 n 19 57 18 Son CPU Load 3 monitoring AN pi at 0 00 00 0 HRD ii 300 agent CPU Load 4 monitoring 900 pout p sat lO 0 00 00 0 See axe 900 agent Application MARE absolute 49 days p fa module 1 15 57 19 l 0 00 00 0 eat callbacks agent New software 6 installation 900 ies 0 0 0 nop 0 a2 daya lo o oo o0o Jo e monitoring agent History control NT 49 days ig 7 eallback isara o 0 90 00 0 cena agent Figure 34 Sample AdvantEDGE View Monitor Table Assigning Entry Rows for the Monitor Table The monIndex column of the Monitor table acts as a key field or row index to distinguish rows in the table Rows 1 through 10 are reserved for internal use by the SystemEDGE agent Users can configure rows in the range 11 to MAXINT This section describes the benefits of reserving a block of rows for use by the system or application administrator Setting Local Policy You may choose as a matter of local policy to reserve a block of rows for system administration This policy allows you to define entries wi
210. e edgewatch 143 45 0 12 private process add procSize netscape 20 0x00a02400 60 absolute gt 35000 Monitor netscape size n The values in this example are defined as follows e procsSize is the process attribute that is being monitored It instructs the agent to monitor the overall size of the program s text data and stack segments e netscape is the application that the agent is monitoring e The flags field of 0x00a02400 instructs the agent to modify the default Process Monitor table behavior as follows 0x00000400 instructs the agent to send processClear traps x00002000 instructs the agent to send up to 10 consecutive traps and then send no more x00a00000 contains the flag value 10 for use with this directive e The greater than gt operator indicates that an event should occur when the process size of netscape exceeds the threshold 35 MB e The threshold is 35 000 KB or 35 MB Monitoring the Windows TCPSVCS Process The following example creates a Process Monitor table entry at index 15 to monitor the Windows TCPSVCS process or service that is running on the target system edgewatch 143 45 0 12 private process add procAlive TCPSVCS 15 0x00 30 Monitor NT TCP services wow eHealth SystemEDGE User Guide Removing Process Monitoring Entries 315 The values in this example are defined as follows e procAlive is the process attribute that is being monitored It instructs the ag
211. e Concord SystemEDGE and all of its components 6 Click Yes to save a copy of the log file or No if you do not want to save the log file The following dialog box appears InstallShield Wizard InstallShield Wizard Complete Setup has finished installing Concord SystemEDGE on your computer Back Eancel eHealth SystemEDGE User Guide Uninstalling the SystemEDGE Agent 101 7 Click Finish Uninstalling an Agent from the Command Line If you installed the agent from the command line you can remove it by running the setup utility with the r argument The r arguments instructs the setup utility to remove SystemEDGE It also removes the sysedge dll sysedge cf sysedge lic and sysedge mon files from the SystemRoot system32 directory NOTE If you want to save these files copy them to another directory before you run the SystemEDGE agent setup utility To remove the command line installation of the SystemEDGE agent for Windows 1 Log on to the Windows system as administrator 2 Change to the SystemEDGE installation directory by entering the following where C sysedge is the directory where you installed the agent C sysedge 3 Enter the following to remove the software setup r Uninstalling SystemEDGE for HP UX Systems Use the HP UX swremove utility to remove the SystemEDGE agent software package EMPsysedge Run the swremove utility by entering the following swremove v
212. e When you execute licenseutil p with the auto option it collects information from all systems in the host list interacts with the CA licensing server to collect the license key information and then populates the sysedge lic file on each of the systems through an SNMP Set command Obtaining a License Key 115 Using licenseutil pl from a System that is Not Connected to the Internet 1 Ensure that the system on which you are running licenseutil pl has connectivity to the systems that require licenses 2 Change to the drive sysedge contrib directory and unzip the licensetools file The distribution includes licenseutil pl sample host files and license files and Perl modules for Perl SNMP queries 3 Edit the licenseutil p and hostlist files as described in Using licenseutil pl from a System that is Connected to the Internet on page 113 4 Run licenseutil pl by entering the following at a command line substituting the product string for product as described in Using licenseutil pl from a System that is Connected to the Internet on page 113 licenseutil pl get hostfile product community port timeout 5 Send an e mail to productlicensing ca com that includes the license file returned by the script and your user name and customer ID CA sends a license file in return 6 Run licenseutil pl again using the set option as follows licenseutil pl set licensefile community port timeout The script perform
213. e collecting history History Control table 206 history sampling 379 History table 205 overview 33 config subdirectory 94 configuration files overview 86 sysedge mon 259 configuring access communities 128 actions 137 agent debugging support 135 AIM support 143 alternative syslog facilities UNIX 134 Windows 134 authentication failure traps UNIX 132 disk probing 136 during installation 118 extension variables 393 history collection support 142 History Control table AdvantEDGE View 384 dynamically 386 emphistory directive 385 methods 384 Linux free memory support 145 log file monitoring 141 Log Monitor table AdvantEDGE View 342 dynamically 345 edgewatch utility 345 methods 343 Monitor table AdvantEDGE View 256 dynamically 261 methods 258 sysedge mon file 259 NT Event Monitor table AdvantEDGE View 368 dynamically 369 methods 368 watch ntevent directive 369 overview 117 permissions for subprograms 142 Process Group Monitor table dynamically 328 methods 328 overview 141 watch procgroup directive 329 Process Monitor table AdvantEDGE View 298 327 dynamically 299 methods 298 support 139 watch process directive 300 Remote Shell group support 133 security 146 status checking floppy devices 135 serial ports 136 sysedge cf file 118 system information UNIX 128 threshold monitoring 245 Top Processes AIM 144 trap communities 130 User and Group support 133 Who Table support 132 Windows event monitoring 357 registry
214. e SystemEDGE agent Monitoring Windows Events The SystemEDGE agent enables you to instruct the agent to continuously monitor Windows event logs This Windows event log monitoring is similar to the standard log file monitoring that is described in Chapter 13 Configuring Log File Monitoring Whenever a matching event is generated on a system that the agent is monitoring the SystemEDGE agent notifies the management system with a trap message It can also execute action commands to handle the event immediately Because Windows events include several identifying characteristics in addition to the text message this monitoring capability is somewhat more sophisticated than the standard log file monitoring in the types of matches that you can specify 357 358 e Chapter 14 Configuring Windows Event Monitoring Monitoring Windows Event Logs The flexible NT Event Monitor Table of the Systems Management MIB is located under the nt system branch in the MIB It enables you to configure the SystemEDGE agent dynamically to monitor event logs for the regular expression that you specify Each entry in the NT Event Monitor table represents the monitoring of one event log for a particular regular expression The NT Event Monitor table monitors the messages that applications log to the Windows event mechanism Windows event monitoring is also useful in security management for example you can configure the agent to monitor the Security Even
215. e 290 Figure 41 shows the agent sending one trap to indicate that the monitored object crossed the threshold and then sending a processClear trap when value drops below the threshold again sample Trap Sent Sample No Trap Sent E anple Clear Trap Sent valle Flags Ox00102400 Threshold Time Figure 41 Sending a processClear Trap eHealth SystemEDGE User Guide Process Monitor Table Flags 295 Figure 42 shows the SystemEDGE agent sending four traps to indicate that the value of the monitored object is above the threshold It does not send a processClear trap when the value falls below the threshold again Sample Trap Sent amp Sample No Trap Sent E Sample Clear Trap Sent vane Flags 0000502000 Threshold Time Figure 42 Sending a Limited Number of Traps with No processClear Trap Figure 43 shows the agent waiting until an event has occurred several times before it begins sending traps It then sends traps until the value of the monitored object falls below the threshold at which time it sends a processClear trap Sample Trap Sent Sample No Trap Sent E sample Clear Trap Sent vag Flags 0x00501400 Threshold Time Figure 43 Sending Traps Only After Multiple Occurrences of an Event eHealth SystemEDGE User Guide 296 e Chapter 11 Configuring Process and Service Monitoring Figure 44 shows the agent sending traps only a specified number of times When the value
216. e History table Depending on available resources the agent sets the empireHistoryBucketsGrant column as close to this value as possible empireHistoryCtrlBucketsGrant Actual number of discrete samples that the agent will save in the History table for the data collection function defined by this entry The agent will keep the most recent Bucket sGrant number of samples empireHistoryCtrlLastCall The last time based on sysUptime that a sample was taken on behalf of this entry empireHistoryCtrlCreateTime Time based on sysUptime at which this history sampling function was created empireHistoryCtrlStatus One of the following active notInService notReady createAndGo createAndWait These values are defined in the SNMPv2 SMI RowsStatus textual convention For more information refer to Appendix E Setting the status to destroy 6 causes the agent to discontinue history sampling for this entry and to delete both this row and the corresponding data sample rows in the History table Columns of the History Table Table 71 describes the columns of the History table For more information about the data storage table refer to the Systems Management MIB specification empire asn1 in the doc subdirectory of the SystemEDGE agent distribution eHealth SystemEDGE User Guide History Control Table and the Data Table 383 Table 71 Columns of the History Table Column Name Deseription empireHistoryIndex Value that identifie
217. e SNMP type including the following Integer e Counter e Gauge e OctetString e TimeTicks e Objectld e IpAddress Windows Registry and Performance Functionality 405 Registry Data The SystemEDGE agent provides data from the standard configuration registry This data is indexed by both a key name and a value For example the key SYSTEM CurrentControlSet Control CrashControl and the value DumpFile identify a text string that describes the location of the system dump file Only LOCAL_MACHINE registry data is supported Table 77 matches the registry data types that the SystemEDGE agent supports with the preferred SNMP type Table 77 Supported Registry Data Types Registry Data Type Suggested SNMIP Types REG_MULT_SZ OctetString only the first string is returned Performance Data The SystemEDGE agent provides access to performance counters in the performance registry by specifying the object and counter names For instance the object NWLink NetBIOS and counter Bytes Total sec identifies the NetBIOS byte counter statistic When using performance counters you must carefully interpret the data At this time there are at least 27 different counter types in Windows Most counters do not actually report the data in the format you would assume based on the name of the counter Instead most values are raw counters that require you to do some post processing such as dividing the difference of two samples by the elaps
218. e System eHealth SystemEDGE User Guide 274 e Chapter 10 Configuring Threshold Monitoring Monitoring the Number of Processes The following example configures the SystemEDGE agent to monitor the number of processes that are currently executing on the system and to send a trap when that number is greater than 120 monitor oid hrSystemProcesses 0 21 0x0 60 absolute gt 120 Monitor Number of Processes The values in this example are defined as follows The hrSystemProcesses variable of the Host Resources MIB is the variable to be monitored e 21 indicates that this entry will be index 21 in the Monitor table e 60 indicates that the agent should sample the number of processes every 60 seconds e absolute is the sample type because the object is a gauge The operator type of greater than or equal to gt instructs the agent to send a trap whenever the number of processes is greater than or equal to 120 e indicates that no action is specified Using the edgemon Utility to Monitor Thresholds eHealth SystemEDGE User Guide edgemon is a command line utility that automatically configures the SystemEDGE agent to monitor a MIB variable that you specify With this utility you specify the following e MIB variable either by name or by object identifier Threshold value and comparison operator Flags e Description e Optional action The edgemon utility then issues an SNMP Set request to crea
219. e SystemEDGE Control Panel to access the configuration and log files to run diagsysedge exe and to start and stop the agent but you do not have to use it for those tasks You can also continue to perform those tasks from the command line sysedge dll SystemEDGE agent dynamic link library SystemEDGE agent executable Subdirectory that contains the SystemEDGE agent dynamic link library as well as several command line utilities for use with SystemEDGE threshold process process group log and Windows event monitoring and history sampling Command line utility for sending user defined traps bounce exe Program for shutting down or rebooting Windows systems You can use this program as an extension or part of an action script with SystemEDGE checkfile exe Program for checking whether a file exists You can use this program as an extension or part of an action script with SystemEDGE eHealth SystemEDGE User Guide SystemEDGE Agent Directories and Files 93 Table 8 SystemEDGE Directories and Files for Windows Systems Page 2 of 3 bin edgewatch exe Command line utility for dynamically configuring the agent to monitor Windows event logs log files and processes edgemon exe Command line utility for dynamically configuring the agent s threshold monitoring emphistory exe Command line utility for use with SystemEDGE history sampling you can use this utility to specify MIB variables to store over time and to retrieve stored
220. e by using the bind_address token as follows bind_address ip address For example to bind to the 10 1 0 202 address only enter the following in sysedge cf bind address 10 1 0 202 Configuring Support for eHealth AIMs The SystemEDGE agent provides a plug in architecture through which you can load optional eHealth AIMs at initialization These eHealth AIMs provide an extensible and flexible approach to supporting application specific MIB variables For the most current list of AIMs refer to the Product Quick List page of the eHealth product Web site http www concord com products quicklist shtml By default the SystemEDGE agent does not load any AIMs at initialization time You can edit the sysedge cf file to specify which AIMs the agent should load You must specify absolute paths to enable the SystemEDGE agent to find the AIM to load eHealth SystemEDGE User Guide 144 e Chapter 4 Configuring the SystemEDGE Agent NoTE The Top Processes AIM is included with the SystemEDGE distribution on every platform This AIM does not require an additional license to operate You can set the agent to load the Top Processes AIM during the SystemEDGE agent installation To load the AIM for Top Processes from the standard Solaris distribution directory for example enter the following in the sysedge cf file sysedge_plugin opt EMPsysedge plugins topprocs so To load the AIM for Top Processes module from the standard
221. e edgemon command and associated arguments are as follows oid object instance index flags interval stype oper val descr action filesystem filesystem name variable name index flags interval stype oper val descr aceion list setstatus index status delete index Table 36 defines the parameters for the edgemon command Table 36 edgemon Command Parameters Page 1 of 2 object instance Specifies the object identifier or object name to monitor You can specify the OID using the complete dotted decimal value for example 1 3 6 1 2 1 25 1 5 0 or the symbolic MIB name for example hrSystemNum Users 0 Either way you must specify the instance which is normally 0 for non tabular MIB variables The object instance or object name must point to a MIB object that exists within the Systems Management MIB the Host Resources MIB or MIB II On Windows systems this object instance or object name can only point to an object within the Systems Management MIB or Host Resources MIB index Specifies the row index of the Monitor table to use for this monitoring entry Each row in the agent s Monitor table is uniquely identified by an index number Rows 1 through 10 are reserved for internal use by the agent so the monIndex value must be greater than 10 flags Specifies the hexadecimal flags for example 0x00000001 that direct the additional behavioral semantics of this Monitor table entry For a list of flags refer to Table 34 on
222. e objects in this group to see if the cache is performing poorly for example if the system has a low cache hit ratio If so your system may need additional memory Figure 13 shows the organization of the NT Cache Performance group ntSystemPerf 1 ntCachePert 2 E nthemoryPert 3 WA ntPageF ilePert 4 E moniterEntry 1 A empireHistoryCtrlentry 1 empireHistoryEntry 1 logMonitarEntry 1 a Windows Specific Groups 195 ntAsyncCopykeads 1 ntAsynclatataps 2 ntAsynck astReads a ntAsynchDLReads 4 ntAsyncPinkeads 5 ntCopyReadHits 6 ntCopyReadst 7 ntDataFlushPages ntOataFlushes 9 ntDatahMapHits 10 ntDatahtapPins 113 ntDatahMaps 12 ntPastReadNotPossible 14 ntPastReadResourceMisses 14 ntPastReads 15 ntLlazyWriterlushes 16 ntLazyWlritePages 17 nthMOLReadHite 19 nthOLReads 14 ntPinReadHite 20 ntPinkeadst 21 ntSyncCopykeads te ntSynclatahMaps 24 Figure 13 NT Cache Performance Group NT Memory Performance Group The NT Memory Performance group contains memory and paging performance counters and statistics that enable you to track the memory usage of your system eHealth SystemEDGE User Guide 196 eHealth SystemEDGE User Guide Chapter 7 Systems Management MIB You can determine for example the following e Amount of available virtual memory e Number of KB being used by the system cache e Number of page faults page reads and p
223. e outcomes e A value is returned indicating that some other management station has already created this conceptual row We return to interaction 1 e The exception noSuchInstance is returned indicating that the agent implements the object type associated with this column and that this column in at least one conceptual row would be accessible in the MIB view used by the retrieval were it to exist For those columns to which the agent provides read create access the noSuchInstance exception tells the management station that it should supply a value for this column when the conceptual row is to be created e The exception noSuchObject is returned indicating that the agent does not implement the object type associated with this column or that there is no conceptual row for which this column would be accessible in the MIB view used by the retrieval As such the management station can not issue any management protocol set operations to create an instance of this column Once the column requirements have been determined a management protocol set operation is accordingly issued This operation also sets the new instance of the status column to createAndGo When the agent processes the set operation it verifies that it has sufficient information to make the conceptual row available for use by the managed device The information available to the agent is provided by two sources the management protocol set operation which creates the conc
224. e request may have succeeded invalid unknown system type The system type of the target SytemEDGE agent is unknown to edgewatch so the utility did not perform the requested operation This error can occur when an older version of the relevant command line utility is used with a newer version of the agent ported to a system not originally supported at the time this utility was written For an updated copy of the utility contact eHealth Technical Support for an updated copy of this utility NT does not support procMonAttribute The Process Monitor attribute that was passed to edgewatch is not supported by the underlying Windows operating system on which the SystemEDGE agent is running The agent therefore does not create a Process Monitor table For a list of Process Monitor attributes that are not supported by Windows refer to the eHealth SytemEDGE Release Notes procAlive is the only attribute which can be applied to a process group The SystemEDGE agent can support process monitoring of groups of processes only if the particular attribute is procAlive If another attribute was passed to edgewatch no operation will be performed Returned system type is not integer edgewatch queries the SystemEDGE agent for its system type this error message indicates that the resulting value was not of type integer Report this error to Technical Support by sending an e mail to support concord ca com Command line Utility Error Messages 4
225. e that was provided to edgemon was not present or mounted on the remote system Consequently the Monitor table entry was not created edgemon internal error please report An internal SNMP library error has occurred within the program Report this error to Technical Support by sending an e mail to support concord ca com GET failed An error occurred while the edgemon utility was communicating with the SystemEDGE agent The request may or may not have succeeded Verify that the community string and target IP address or system name are correct GET_NEXT failed An error occurred while retrieving and parsing the Systems Management MIB Mounted Device table perhaps due to a dropped SNMP packet or a SystemEDGE agent error The operation may or may not have succeeded For more information refer to the other error or information messages returned by edgemon monitor WSAStartup failed On Windows systems the monitor command was unable to initialize the WinSock library and could not communicate with the targeted SystemEDGE agent The requested action therefore was not performed Object is not Integer based The MIB object that was specified for monitored through the SystemEDGE agent s Monitor table was not an integer based object so no monitor table entry was created The agent can perform self monitoring only on integer based MIB objects including counters gauges timeticks and integers eHealth SystemEDGE User Guide
226. e the SystemEDGE agent to monitor the system s 1 minute load average monitor oid 1 3 6 1 4 1 546 1 1 7 8 26 0 11 0x00 60 absolute gt 300 Monitor 1 minute load average monitor oid loadAveragelMin 0 11 0x00 60 absolute gt 300 Monitor 1 minute load average The values in these examples are defined as follows e 1 3 6 1 4 1 546 1 1 7 8 26 0 corresponds to the OID for the loadAveragelMinute variable contained within the Systems Management MIB e 11 indicates that this entry will occupy row 11 monIndex 11 in the Monitor table e 60 specifies that the load average should be sampled once every 60 seconds e absolute indicates that the agent should use the object s value not the difference between successive samples e 300 is the value against which the current load average is compared If the currently sampled value is greater than gt 300 an event occurs NOTE The agent returns load averages as the underlying system s load average multiplied by 100 For example a load average of 3 is returned as 300 eHealth SystemEDGE User Guide Threshold Monitoring Examples 265 Monitoring the 5 Minute Load Average The following example configures the SystemEDGE agent to monitor the system s 5 minute load average monitor oid loadAverage5Min 0 12 0x00500300 300 absolute gt 200 Monitor 5 minute load average The values in this example are defined as follows loadAverage5Min 0 corresponds to the OI
227. eX C gt 98 machineX You can add history collection entries to the agent via the configuration file keyword emphistory Usage emphistory Index Interval ObjectID buckets Description Examples emphistory 12 120 swapCapacity 0 30 Swap capacity history emphistory 13 60 memInUSeCapacity 0 60 MemInUse capacity history emphistory 14 60 memInUse 0 60 MemInUse history emphistory 11 30 loadAveragelMin 0 60 l min load average history emphistory 15 60 numPageFaults 0O 200 Page Faults Optional plugins Example for Service Response sysedge_plugin c sysedge plugins svcrsp sversp dll Optional plugins Example for Top Processes sysedge_plugin C sysedge plugins topprocs topprocs dll eHealth SystemEDGE User Guide 128 e Chapter 4 Configuring the SystemEDGE Agent Configuring System Information The SystemEDGE installation enabled you to define system location and contact If you want to modify those values you can do so manually in the sysedge cf file You can update the syscontact and syslocation fields as follows Replace System contact unknown With the name of the person who is the contact for this system Replace System location unknown with a short description of the system s physical location For example specify QA Lab Configuring Access Communities You can use any ASCII characters for the community name eHealth SystemEDGE User Guide The SystemEDGE installation enabled you to define read only
228. ealth SystemEDGE User Guide Windows Registry and Performance Examples 409 Table 80 Parameters for the ntRegPerf Command Page 2 of 2 Selects a configuration registry entry Selects a configuration registry entry Key Quoted string that is 0 through 512 characters in length and that specifies the registry key to be accessed Value Quoted string that is 0 through 128 characters in length and that specifies the registry key s value to be accessed Object Quoted string that is 0 through 512 characters in length and that specifies the performance object to be accessed Counter Quoted string that is 0 through 128 characters in length and that specifies the object s performance counter value to be accessed PerfInstance Quoted string that specifies the performance counter instance to be accessed it should be equivalent to that listed in the Windows perfmon utility Windows Registry and Performance Examples The SystemEDGE agent includes several sample ntRegPerf variables These examples are defined in the sample sysedge cf file Before you add your own ntRegPerf extension study these examples and their definitions in the Systems Management MIB empire asn1 in the doc subdirectory of the SystemEDGE agent distribution For clarity these examples include the appropriate configuration file ntRegPerf commands CrashControl DumpFile The following ntRegPerf object returns the path to the dump file ntregperf 1 Octe
229. ece ce eee eee enee 218 logMonNotReady Trap 0 cece cece eens 219 ntEventMonMatch Trap 0 ce cece eee ees 220 ntEventMonNotReady Trap 0 cece cece eee 221 mMm nitorClear 11404 46 44420 ns eee oreanGenoususeues 222 processStOp Irap cscscstchoewhsatene bese sdtaesdade 223 processStart THAD e642 5cc eras cette todos oe see ar ees se 224 processThreshold Trap 0 cece cece eee e eee ees 225 ProcessClear Wap srei oreen stace sonan SEERE 226 Hcense TiiPecresrie terrenin isror arr erh enaaueenes 227 addi Change T iaD aaeeeiai kA E RE DE 228 procGroupChangeTrap cece eee eee ee eee 229 SNMP Trap Formia 22ic0 edcasbtasteasonin eeete teens 230 Host Resources MIB 233 Host Resources System Group 2 eee eee ee eee 234 Host Resources Storage Group 00 e eee eee eee 236 Host Resources Device Group 0 cece eee eee 236 Device TAD sessi uenee i ee A 2a Processor VADIC jcecece ere duh atedenecncies E 238 Disk St0rdce Lave wo annsngasantacatoeges cae ea 239 Partition Table 25455 6eopnenser toeeend bene Meee GERi 239 File System Table 2 0202 csseese0hs00 dads ctendew owed 240 Host Resources Running Software Group 005 241 Host Resources Installed Software Group 0006 242 Unsupported MIB Objects on Windows Systems 243 eHealth SystemEDGE User Guide 10 e Table of Contents Chapter 10 Configuring Threshold Monitoring 245 Threshold M
230. ece cece eee ee eee 457 log NCIS MOU TCCUIAE 224s Gis bn s6besteen eee shaeG hands 457 log filename too long 2 6ii250 404euheadbaeetaveniess 457 logmon entry X re initialized 0 00 eee eee eee 457 logmon regcomp failed X 2 0 eee eee eee 457 logmon trap entry not ready Index X 4 458 l gmon trap Index X rerus stegies dpanedwe oeewaeen ged 458 logmonitor action execution failed 458 malloc of trap contents failed 0 0 cc cece eee 458 monitor action execution failed 0 00 e eee 458 monitor entry X not ready cece cece eee eee 459 monitor trap Index X 2608 sike wend ence w de daun desea 459 monprocess requires regular expression 459 nlist of unix failed 200s ceye sees ences enes eee smeter ewes 459 no extension variable found for X 00s eee 460 non existent object to track history of 460 no process matching expression 0 eee ee eee 460 not querying serial port statuS 0 cece eee eee 460 not sending authen failure traps 0 00 00 461 not stat ing disks devices 0 ce eee cece eee ences 461 not stat ng floppy devices 0 cece cece eee eee 461 not stating NFS filesystems 00 e eee ee ee eee 461 not supporting actions eee eee eee eee 461 not supporting remoteShell group 0005 461 not supporting user group tables 0
231. ect identifier value The Set operation referenced by this message failed setMonEntry invalid oper An SNMP Set operation to the Log Monitor table contained an improper operator type The Set operation referenced by this message failed setMonEntry invalid oper type An SNMP Set operation to the Log Monitor table contained an improper operator type The Set operation referenced by this message failed setMonEntry invalid stype An SNMP Set operation to the Log Monitor table contained an improper sample type The Set operation referenced by this message failed setMonEntry invalid type for OID An SNMP Set operation to the Log Monitor table contained an improper object identifier type The Set operation referenced by this message failed setMoneEntry invalid type for val An SNMP Set operation to the Log Monitor table contained an improper value type The Set operation referenced by this message failed eHealth SystemEDGE User Guide 466 e Appendix A Error Messages setMoneEntry oid type invalid An SNMP Set operation to the Log Monitor table contained an improper object identifier type The Set operation referenced by this message failed setMonEntry stype type invalid An SNMP Set operation to the Log Monitor table contained an improper sample type The Set operation referenced by this message failed stat logfilename failed The SystemEDGE agent could not determine file information for a particular log file
232. ect instance must exist and must be contained within the SystemEDGE agent s supported MIBs That is any supported integer based object that exists in MIB II the Host Resources MIB or the Systems Management MIB is valid Objects should be of integer type including counter gauge integer or enumerated integer eHealth SystemEDGE User Guide 496 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Table 86 Fields for Monitor Table Entries in sysedge mon Page 2 of 3 monValue monRowStatus monAction The operator type is a boolean operator used for evaluating the expression currval operator value The operator can be one of the following nop no operation monitor the object s value but do not evaluate the Boolean expression et greater than It less than ge greater than or equal to le less than or equal to eq equal ne not equal Integer value to which the current value of the monitored MIB variable is compared during each monitoring cycle If the comparison evaluates to true where the operator type tells how to compare them the agent sends a trap For example if you wanted to be notified if the value of some gauge goes over 100 you would set 100 as the monValue against which the current value of the gauge is compared One of the following e active e notInService notReady e createAndGo e createAndWait Normally a row is either active or notInService These values are identical
233. ect the value of a MIB variable over time the manager can instruct the agent to sample and store the values The management system can contact the agent periodically to upload the complete history of samples An additional benefit of history collection is that the agent will continue to sample and store the specified MIB values even during periods of network outage when the management system cannot communicate with the agent 379 380 e Chapter 15 Configuring History Collection History Sampling The agent uses two SNMP MIB tables to provide the history capability e History Control table a control table for defining the data collection functions e History table a data table for storing the actual data samples The control table enables you to dynamically configure the agent to sample and store the values of any integer based MIB variable under its control The data table stores the values for future retrieval To perform baselining and trend analysis you can configure the SystemEDGE agent to monitor and store the values for swapCapacity for example by configuring the agent to sample the value every 5 minutes and to store the most recent 144 samples Then once every 12 hours the NMS can upload the entire 144 samples to obtain the values for swapCapacity that were collected during the preceding 12 hour period The swapCapacity variable of the Systems Management MIB specifies the percentage of swap space that is currently in us
234. ed eHealth SystemEDGE User Guide 146 e Chapter 4 Configuring the SystemEDGE Agent Recommendations for Configuring Security eHealth SystemEDGE User Guide Table 11 lists recommended configuration options for ensuring security Table 11 Recommended Settings for Ensuring Secure Systems no_who_table Configuring Support for Who Table Information on page 132 no_usergroup_table Configuring Support for User and Group Information on page 133 no_remoteshell_group Configuring Support for Remote Shell Capability on page 133 no_process_sets Configuring Support for Process Monitoring on page 139 Table 12 lists additional configuration options that can help ensure security Table 12 Additional Settings for Ensuring Secure Systems no_actions Configuring Support for Actions on page 137 no_process_table Configuring Support for Process Monitoring on page 139 subprogram_user_name Configuring User Group Permissions for Subprograms UNIX Only on page 142 subprogram_group_name Configuring User Group Permissions for Subprograms UNIX Only on page 142 Using the SystemEDGE Control Panel for Windows 147 Using the SystemEDGE Control Panel for Windows As a standalone Windows service SystemEDGE 4 2 and later has its own SystemEDGE Control Panel To view the SystemEDGE Control Panel open the Control Panel dialog box and double click eHealth SystemEDGE SystemEDGE Control Panel
235. ed as follows e 11 indicates that this entry will occupy row 11 pgmonIndex 11 in the Process Group Monitor table The flags field value of 0x00 indicates the default behavior e 60 indicates that the agent should check the emacs process group every 60 seconds e No action is specified so the agent invokes no command when it sends a trap eHealth SystemEDGE User Guide Removing Process Group Monitoring Entries 331 Monitoring the DT Process Group The following example configures the SystemEDGE agent to monitor the DT process group Watch procoroup diybin 12 0x00 60 Watch DT stuff The values in this example are defined as follows e 12 indicates that this entry will occupy row 12 pgmonIndex 12 in the Process Group Monitor Table The flags field value of 0x00 indicates the default behavior e 60 indicates that the agent should check the DT process group every 60 seconds e No action is specified so the agent invokes no command when it sends a trap Removing Process Group Monitoring Entries To stop the self monitoring of a particular process group you must remove the appropriate entry from the Process Group Monitor table The watch procgroup directives in the sysedge cf file will create a Process Group Monitor table entry whenever the SystemEDGE agent is started This row creation results in a new Process Group Monitor table entry that will be stored in sysedge mon Thus permanent removal
236. ed time If you see a counter name like Bytes Total sec the data you are really getting is a raw counter that can be used to calculate this rate value eHealth SystemEDGE User Guide 406 e Chapter 17 Adding Windows Registry and Performance MIB Objects NOTE Familiarize yourself with Windows Performance counters before using this feature of the SystemEDGE agent For more information refer to the section on optimizing Windows in the Windows Resource Kit Table 78 matches the 4 byte performance data types that the SystemEDGE agent supports with the preferred SNMP types Table 78 Supported 4 Byte Performance Counter Types PERF_SAMPLE_ COUNTER Counter integer or gauge Table 79 matches the 8 byte performance data types that the SystemEDGE agent supports with the preferred SNMP types Because SNMPv1 supports only 4 byte values SystemEDGE will return only the least significant 4 bytes of data Table 79 Supported 8 Byte Performance Data Types Page 1 of 2 8 Byte Performance Data Type Suggested SNMIP Types PERF_COUNTER_TIMER Counter integer or gauge PERF_COUNTER_BULK_COUNT Counter integer or gauge eHealth SystemEDGE User Guide Windows Registry and Performance Functionality 407 Table 79 Supported 8 Byte Performance Data Types Page 2 of 2 Unsupported Performance Data Types Several counters require significant post processing with multiple samples and internal data that is difficult to present in a single
237. edgewatch utility That is you can configure event monitoring on a Windows system by using edgewatch from a Solaris system You can use edgewatch to add delete set the status of or list entries in the NT Event Monitor table You can use the edgewatch utility as follows edgewatch hostname port timeout community ntevent command eHealth SystemEDGE User Guide Using the edgewatch Utility to Monitor Windows Events 373 Table 68 describes the parameters of the edgewatch utility Table 68 Parameters of the edgewatch Utility Parameter Description hostname port timeout Hostname or IP address in dotted quad notation of the system on which the SystemEDGE agent exists If the agent is running on an alternative UDP port for example 1691 specify that port number through a colon separator In addition you can specify an optional SNMP timeout value in seconds using a command separator community SNMP community string to use when performing the specified command The community string should have read write access on the target agent for add delete and setstatus operations For the list operation the community string need only have read access command Command and associated arguments Supported commands include add setstatus delete and list For more information refer to the next section edgewatch Commands for NT Event Monitoring edgewatch Commands for NT Event Monitoring This section describes t
238. efined separately for each of the self monitoring tables This field defines the next 12 low order bits after the common table flags Field 3 Reserved 12 high order bits for an integer value for use in conjunction with table specific flags Flags in the Process Group Monitor table specific flags field define the contents of this field eHealth SystemEDGE User Guide 326 Chapter 12 Configuring Process Group Monitoring The following sections explain each flag bit You can combine flag values through a logical OR operation One flag is specific to the Process Group Monitor table 0x00100 This flag instructs the SystemEDGE agent to match the process name and arguments for this entry Table 48 describes the Process Monitor table flags Table 48 Process Group Monitor Table Flags Fin a A 0x00000001 Do not execute actions for this entry 0x00000002 Do not send traps for this entry This flag bit overrides any other flag bit with respect to traps 0x00000004 Do not attempt to reinitialize this entry By default the agent periodically tries to reinitialize this table entry by scanning the process table to determine the new process ID if the target process has been restarted Setting this bit disables automatic reinitialization 0x00000008 Do not record events for this entry in the syslog facility Setting this bit does not affect trap sending or threshold monitoring It prevents the event from being logged through syslog only On Win
239. eld installation If you have installed SystemEDGE with InstallShield and you want to upgrade from the command line you must uninstall the InstallShield version as described in Uninstalling an Agent with InstallShield on page 99 and then reinstall using the procedure in this section Log on to the Windows system as administrator and insert the AdvantEDGE CD ROM into the CDROM drive Windows automatically mounts the drive Run the self extracting executable by entering the following at the command line where D is the CD ROM drive D sysedge wincmd sysedge exe C The agent is installed in C sysedge Installing SystemEDGE on HP UX Systems 75 Installing SystemEDGE on HP UX Systems This section describes how to install the SystemEDGE agent on HP UX systems See the Preface for a list of supported systems and versions System Requirements Before you begin installing the agent verify that your system meets the following requirements e CD ROM drive At least 8 MB RAM At least 4 MB free disk space Installing the Software Hewlett Packard defines a The SystemEDGE agent software distribution for HP UX is software depot as a group of formatted as an HP software depot This distribution uses the related file sets swinstall utility to install the agent To install the software 1 Login as root by entering su and then the root password at the password prompt 2 Insert the CD that contains the so
240. emEDGE User Guide Hypertext Transfer Protocol HTTP HTTP is the set of rules for exchanging files text graphic images sound video and other multimedia files on the World Wide Web WWW Relative to the TCP IP suite of protocols which are the basis for information exchange on the Internet HTTP is an application protocol You can easily distribute SystemEDGE agents through the Web by placing them on a Web page for downloading and installation File Transfer Protocol FTP FTP a standard Internet protocol is the simplest way to exchange files between computers on the Internet Like HTTP which transfers Web pages and related files and SMTP which transfers e mail FTP is an application protocol that uses TCP IP FTP is commonly used to transfer Web page files from the computer where they were created to the computer that acts as their server FTP is also commonly used for downloading programs and other files to your computer from other servers Remote Copy Protocol RCP RCP enables you to integrate remote copy operations into your applications An application can copy files between the local and remote machine or from one remote machine to another RCP commands support recursive file copying and can preserve the original time and date attributes of the file Remote Distribution RDIST RDIST maintains identical copies of files over multiple hosts It preserves the owner group mode and modification time of files and can upda
241. emEDGE agent is disabling support of SNMP Sets to the process table according to the configuration file directive eHealth SystemEDGE User Guide SystemEDGE Agent Error Messages 469 two processes with PID X The SystemEDGE agent has discovered two separate distinct processes with the same process identifier Although this condition is technically impossible the SystemEDGE agent still guards against it This message indicates that the agent has discovered this situation and has properly accommodated it two software packages with same index The SystemEDGE agent has discovered two software packages with the same index value This condition can occur when local users have changed files in the system s software installation area or if those files have been damaged This message indicates that the SystemEDGE agent has discovered the situation and has properly accommodated it Report the conditions that generated this message by sending an e mail to support concord ca com unable to open monitor file The SystemEDGE agent was unable to open the monitor file that was specified as a command line argument or was unable to open the default monitor file Verify that the monitor file that is specified as part of the UNIX command line is specifying a valid monitor file or that the default monitor file is in the proper location The default monitor file sysedge mon is contained in the UNIX dir directory or in the Windows SystemRoot syste
242. ement system The management system sends messages to the agent processes on the managed devices to request information or to modify parameters The agent process carries out the management system s request and returns a reply Additionally the agent can send its own messages traps to the management system to notify it of important events SNMP is the protocol that the agent and management system use to exchange this management information eHealth SystemEDGE User Guide 48 e Chapter 1 Introduction SNMP Message Types The SystemEDGE agent uses standard SNMP messages to exchange management information with management systems Table 4 describes the SNMP message types Table 4 SNMP Message Types GetRequest An NMS sends a GetRequest to an agent to obtain the value of a specific object instance from the MIB GetNextRequest An NMS sends a GetNextRequest to an agent to obtain the next object instance GetResponse An agent returns the requested information to an NMS through a GetResponse SetRequest An NMS sends a SetRequest to instruct an agent to change the value of a MIB object s parameters Trap An agent sends a trap to notify an NMS of exceptions SNMP Communities eHealth SystemEDGE User Guide In SNMP a community is a relationship between an agent and any number of management systems it defines authentication and access control permissions for communication between the management systems and the agent An SNMP co
243. ement software 410 O obtaining diagnostic information about the agent 423 troubleshooting data 423 obtaining a license key 108 operating system patches 437 operating systems supported 23 optimizing row creation History table 383 Log Monitor table 337 Monitor table 251 NT Event Monitor table 363 Process Group Monitor table 324 Process Monitor table 289 patches required 437 perfmon extensions 34 ping sh file 97 platforms supported 23 private enterprise traps 215 procAlive attribute 302 process attributes 287 Process Group Monitor table actions 326 assigning entry rows 327 columns 320 configuring support 141 default action parameters 326 description 320 examples monitoring DT process group 331 monitoring emacs process group 330 monitoring httpd process 505 monitoring xterm process group 330 flags 325 overview 203 319 removing entries 331 sample sysedge mon entries 505 watch procgroup directive 329 process group monitoring configuring support 141 introduction 32 Process Monitor table actions default parameters 296 disabling 291 overview 297 adding entries through sysedge mon 499 503 AdvantEDGE View display 298 327 Index e 539 assigning entry rows 298 columns 284 configuration examples 306 configuring support 139 description 284 disabling traps 291 examples monitoring netscape process 502 monitoring process size 309 monitoring sendmail 307 monitoring Simple TCP IP Services service 308 monitori
244. empts 344 su attempts 345 security log for failure events 371 security issues deploying the agent 420 action commands 421 extension variables 421 MIBs 421 self monitoring 31 sending signal to a process 176 sendpage pl 97 sendtrap utility directory 90 error messages 481 sendtrap 1 Man page 91 sendtrap exe 92 sendtrap txt 94 serial ports configuring status checking 136 service monitoring 32 setting policy for monitoring tables 257 status of History Control table entries 389 signal sending to a process 176 smtp listenq sh 97 SNMP access communities 49 communities 48 deleting rows 522 message types 48 overview 47 requests troubleshooting 425 row creation 516 row suspension 522 supporting multiple agents 157 trap communities 50 severity levels 436 troubleshooting 428 snmpget utility error messages 483 Solaris installing SystemEDGE 52 platform support 23 removing SystemEDGE 98 starting SystemEDGE 152 system requirements 52 Solstice Enterprise Agent 160 specifying access list 129 MIB objects to monitor 259 starting SystemEDGE automatically 151 AIX 154 Digital UNIX 155 HP UX 153 Linux 154 Solaris 152 Tru64 155 command line 150 overview 149 starting Windows Master agent 153 stopping Windows Master agent 150 Streams Buffer Allocation table Systems Management MIB 183 group systems Management MIB 170 subprogram support configuring 142 Index 541 supported platforms 23 supporting custom MIB objects 34 mul
245. ent Source when scanning the events for matches eHealth SystemEDGE User Guide 362 e Chapter 14 Configuring Windows Event Monitoring Table 63 Columns of the NT Event Monitor Table Page 3 of 3 Column Name Permissions Description ntEventMonDescLastMatch Read Only Description string of the last event log entry that matched this monitor entry Each time a match occurs this variable is updated ntEventMonDescFilter Read Write Regular expression to apply to the Event Description when scanning the events for matches ntEventMonStatus Read Write SNMPv2 RowStatus one of the following e active 1 e notInService 2 e notReady 3 ntEventMonDescr Read Write Quoted string that is 0 to 128 characters in length and that normally contains a description of the events that are being monitored as well as a severity level for this event ntEventMonAction Read Write Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when a match is found and a trap is sent If the string is empty the agent invokes no action for this entry ntEventMonFlags Read Write Unsigned integer flags value indicating additional behavior that this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field refer to NT Event Monitor Table Flags on page 363 eHealth System
246. ent is running or you can define them in the sysedge cf configuration file For more information about creating entries in the Process Monitor table refer to Chapter 13 Configuring Log File Monitoring Configuring Support for Windows Event Log Monitoring Windows Only The SystemEDGE agent includes a Windows Event Monitoring capability that lets you instruct the agent to continuously monitor Windows event logs in much the same way that it monitors textual log files Whenever a matching event is generated on the system the agent notifies the management system with a trap message and can execute an action command to immediately handle the event Because Windows events eHealth SystemEDGE User Guide 142 e Chapter 4 Configuring the SystemEDGE Agent include several identifying characteristics in addition to the textual message this monitoring capability enables you to specify more sophisticated types of matches For more information about creating entries in the Process Monitor table refer to Chapter 14 Configuring Windows Event Monitoring Configuring History Collection The SystemEDGE agent can track the value of various integer based MIB objects counters gauges and so on over time and can store them for later retrieval You can define entries for history collection in the sysedge cf configuration file that the SystemEDGE agent reads when it starts For more information about creating entries in the Process Monit
247. ent system NMS platforms such as eHealth Aprisma SPECTRUM Sun Domain Manager HP OpenView IBM NetView 6000 Micromuse Netcool and others In addition the SystemEDGE agent supports the ability to monitor objects from several management information bases MIBs Supported MIBs A management system monitors a managed resource by reading the values of its MIB objects It can also control the resource by modifying setting the values of objects in the resource s MIB through SNMP commands eHealth SystemEDGE User Guide A MIB is a virtual information store in which an agent stores information about the elements under its control Each item of management information is represented by an object and the MIB is a structured collection of these objects MIBs are defined in a MIB specification that describes the management objects relating to a particular resource The MIB specification also defines how the collection of objects is structured The MIB module resembles a data definition document that is used by both the management system and the agent The SystemEDGE agent supports the following MIBs e MIB II RFC 1213 e Host Resources MIB RFC 1514 e Systems Management MIB MIB Il MIB II is the standard that provides information about network interfaces and protocol statistics This MIB includes information about the following protocols Internet Protocol IP e Transfer Control Protocol TCP Usi
248. ent to scan the Process Monitor table periodically every 30 seconds to ensure that this process is running e TCPSVCS is the Windows service that is responsible for TCP related services on Windows systems e The flags field of 0x00 instructs the agent to provide the default behavior for this table entry Removing Process Monitoring Entries To stop the self monitoring of a particular process attribute you must remove the appropriate entry from the Process Monitor table The watch process directives in the sysedge cf file creates a Process Monitor table entry whenever the SystemEDGE agent starts This row creation results in a new Process Monitor table entry that is stored in sysedge mon Thus permanent removal of a Process Monitor table entry requires two steps 1 Remove the entry from the sysedge cf file 2 Remove the entry from the Process Monitor table Removing Entries from the sysedge cf File If you configured a Process Monitor table entry by adding a watch process directive to the sysedge cf file you must remove it from that file as part of removing the entry from the table If you do not remove the sysedge cf directive the entry will be recreated the next time the SystemEDGE agent starts eHealth SystemEDGE User Guide 316 e Chapter 11 Configuring Process and Service Monitoring Removing Entries with the edgemon Utility To remove a process monitoring entry from the Process Monitor table use the edgemon utility
249. entries Configuring the Monitor Table eHealth SystemEDGE User Guide You can control which MIB variables and conditions the SystemEDGE agent monitors using its threshold monitoring capability by adding deleting or modifying the entries in the Monitor table You can configure the Monitor table in the following ways Dynamically Use SNMP commands from a management system such as AdvantEDGE View to modify the table For more information refer to Dynamic Configuration During Operation on page 261 At start up initialization Specify the entries for the Monitor table in the sysedge cf file that the agent reads on start up For more information refer to the next section Initial Configuration During Startup Configuring the Monitor Table 259 Initial Configuration During Startup On startup the agent reads the sysedge cf file You can use this file to specify which MIB variables you would like SystemEDGE to monitor by adding entries with the monitor configuration file keyword For more information refer to Adding Entries with the monitor Directive on page 261 Selecting Objects for Monitoring This section describes the process of specifying MIB objects for monitoring by adding them to the sysedge cf file As an alternative you can specify MIB objects through SNMP Set operations For more information refer to Dynamic Configuration During Operation on page 261 To specify MIB objects for
250. eptual row and implementation specific defaults supplied by the agent note that an agent must provide implementation specific defaults for at least those objects which it implements as read only If there is sufficient information available then the conceptual row is created a noError response is returned the status Conceptual Row Creation 519 column is set to active and no further interactions are necessary i e interactions 3 and 4 are skipped If there is insufficient information then the conceptual row is not created and the set operation fails with an error of inconsistentValue On this error the management station can issue a management protocol retrieval operation to determine if this was because it failed to specify a value for a required column or because the selected instance of the status column already existed In the latter case we return to interaction 1 In the former case the management station can re issue the set operation with the additional information or begin interaction 2 again using createAndWait in order to negotiate creation of the conceptual row NOTE Regardless of the method used to determine the column requirements it is possible that the management station might deem a column necessary when in fact the agent will not allow that particular columnar instance to be created or written In this case the management protocol set operation will fail with an error such as noCreation or notWriteab
251. er 8 Private Enterprise Traps processstart Trap The following code shows the format of a processStart trap which the SystemEDGE agent sends to indicate that a process has restarted and has been reacquired by the SystemEDGE agent processStartEvent OBJECT IDENTIFIER traps 11 processStartTrap TRAP TYPE ENTERPRISE sysmgmt VARIABLES pmonIndex pmonDescr pmonAttribute pmonCurrVal pmonOperator pmonValue pmonFlags pmonRegExpr pmonCurrentPID DESCRIPTION This Trap is sent when using a Process Monitor Table entry to monitor the state of a process When a process is re started and subsequently re acquired by the SystemEDGE agent this Trap is sent This Trap is sent if the value of pmonFlags specifies that processStart Traps should be pay 11 eHealth SystemEDGE User Guide Format of Trap PDUs 225 processThreshold Trap The following code shows the format of a processThreshold trap which the SystemEDGE agent sends to indicate that an attribute of a process that it is monitoring has reached the specified threshold processThresholdEvent OBJECT IDENTIFIER traps 12 processThresholdTrap TRAP TYPE ENTERPRISE sysmgmt VARIABLES pmonIndex pmonDescr pmonAttribute pmonCurrVal pmonOperator pmonValue pmonP lags pmonRegExpr pmonCurrentPID DESCRIPTION This Trap is sent when using a Process Monitor Table entry to monitor some attribute e g memory usage process size of a process
252. er you should add more memory to your system The NT Page File Performance group includes the following MIB objects e ntPageFileUsage which provides the percentage of the page file space that is currently being used e ntPageFilePeakUsage which provides the maximum percentage of the page file s that were used when memory demand was at its peak NT Event Monitor Group Windows uses event logs to capture important system and application status messages You can use the SystemEDGE agent Windows event monitoring capability to instruct the agent to continuously monitor Windows event logs for specific events that you specify Whenever a matching event is generated on the system the agent notifies the management systems with a trap message The agent can also execute an action command to immediately handle the event The NT Event table provides detailed status information for each monitor entry For more information about using Windows event monitoring refer to Chapter 14 Configuring Windows Event Monitoring eHealth SystemEDGE User Guide 198 e Chapter 7 Systems Management MIB Table 23 describes the NT Event Monitor group MIB objects Table 23 NT Event Monitor Group MIB Objects ntEventMonSrcFilter Event source regular expression to match ntEventLastMatch Event description of the last match ntEventMonDescFilter Event description regular expression to match ntEventMonAction Action to perform if a match is found nt
253. erActiveNode 46 For descriptions of these MIB objects refer to the empire asn1 file in the doc subdirectory of the SystemEDGE agent distribution NT Thread Group In the Windows operating system the kernel schedules threads to run on the processor s A thread is a part of a process that executes program code A process may contain one or many threads Use the NT Thread table to obtain detailed status information for each thread that is executing on the system including the following e Process to which the thread belongs e Number of seconds the thread has been running Percentage of time that the thread has run in user and privileged modes e Current state of the thread ready running wait terminated and so on e Reason a thread is waiting if it is in a wait state Table 21 describes the NT Thread group MIB objects Table 21 NT Thread Group MIB Objects Page 1 of 2 ntThreadPID Process to which the thread belongs ntThreadNumber ID Number for the thread within the process ntThreadPrivTime Percent of time that the thread was executing in privileged mode eHealth SystemEDGE User Guide Windows Specific Groups 191 Table 21 NT Thread Group MIB Objects Page 2 of 2 ntThreadProcTime Percent of time that the thread was using processor to execute commands ntThreadUserTime Percent of time that the thread was executing in user mode ntThreadContextSwitches Number of context switches ntThreadElapsedT
254. erating Systemi VECO eseese esa Soranee se ehen eee eueee eee 430 Bind Failed Address Already In Use 0005 433 Updating the Monitor Configuration File 433 Automatically Restarting Processes 00 eee 436 Implementing Trap Severity Levels 00 436 Required and Recommended System Patches 437 eHealth SystemEDGE User Guide 16 e Table of Contents Appendix A Error Messages 439 SystemEDGE Agent Error Messages 2 200 439 action execution failed cee cece cece eee eee 439 authenFailure src A B C D community X 439 bad ioconfig magic s2 ven cen dene as ana ees oo dewe oe ieee c 440 bad pid X for write_runStatus 2 04020020 5e0s40es40004 440 bad shellOutput directory X 1 0 eee cee eee 440 bad shellOutput file Xo vi05ite0deavedes sons tianseaca 440 Bind i s occeonseccen er saeenaseserseseeeuseuaess 440 block size for X is 0 using 1K eee eee eee ee 441 cant Open KINEM 642206400544 54 80 eonGecedbGiaiennees 441 cannot find title index for 0 0 cece cece eee eee 441 cannot locate disk pstat data diskStatsTable not supported 441 CAME open kme 245 45 52 xnab8esaSeeesunehinaangeewesss 441 cant open socket for mib 2 0 0 cece cece eee 442 caugh SIGIIUL caceeeusacesesnseans son pamemeee cea 442 config file error in subprogram_user_name directive 442 config syntax error line Xo eee eee ees 442 Could not find a
255. erating system release number for a UNIX system where the SystemEDGE agent is on port 1691 and the community string is public enter the following sysvariable 127 0 0 1 1691 public r Common Problems and Questions 427 For a Windows system where the SystemEDGE agent is on port 1691 and the community string is public enter the following C sysedge bin gt sysvariable exe 127 0 0 1 1691 public r Is the SystemEDGE Agent Licensed Correctly To verify that the agent is licensed correctly refer to SystemEDGE Agent Not Accepting Valid License on page 429 Are the SystemEDGE Agent Binaries and Configuration Files Installed To verify that the correct agent binaries and configuration files are installed refer to Agent Does Not Run on A Particular Operating System Version on page 430 Is the SystemEDGE Agent Co Existing with Other Agents If you are using other agents with the SystemEDGE agent verify their coexistence setup exe c v Is the SystemEDGE Agent Configured Correctly To verify that the agent is configured correctly check the communities and access control lists On UNIX systems examine etc sysedge cf for community strings and access control lists If an alternative configuration file is in use verify that the agent is using that alternative configuration file e On Windows systems verify access controls and communities through the Network Control Panel For more information refer
256. erating system the instructions apply 23 24 e Preface Audience About This Guide NOTE Throughout this guide the terms Windows and Windows NT encompass Windows NT 4 0 Windows 2000 Windows XP and Windows 2003 If you are using Windows NT 4 0 you must be using SP 6a or later This guide is intended for an administrator who is installing configuring and using the SystemEDGE agent to manage UNIX and Windows workstations It assumes that you have a basic familiarity with your system s operating system environment and with the Simple Network Management Protocol SNMP This section describes the changes and enhancements that have been made since the last release of this guide It also includes the documentation conventions used in this guide Revision Information eHealth SystemEDGE User Guide This section describes the changes in this guide since SystemEDGE 4 2 Patchlevel 3 Added information about new operating system support to the Preface and Chapter 2 Sun Solaris 2 10 AMD64 e HP UX PA RISC 11 0 111 and 11i v2 11 23 e SUSE Linux Enterprise Server 10 x86 AMD64 EMT64 Itanium About This Guide 25 Documentation Conventions Table 1 lists the conventions used in this document Table 1 Documentation Conventions File or Directory Name Text that refers to file or directory names code Text that refers to system code or operating system command line examples emphasis Text that refer
257. ers to the watch process procAlive directive Table 42 Watch Process ProcAlive Parameters procname Quoted string that specifies the regular expression to apply when attempting to match a process name and optional arguments Note Because the Windows kernel does not track the arguments used in a process the SystemEDGE agent does not match process arguments for Windows systems index Row index to use for this entry flags Specifies any additional non default behavior to apply to this entry Specify all flags as hexadecimal numbers for example 0x0000 interv Interval that indicates how often in seconds the agent monitors the process daescripli on Quoted string that is 0 to 128 characters in length and that normally contains a description of the process and attribute that the agent is monitoring as well as severity level for this event acraon Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to execute when the process starts or stops If the string is empty the agent performs no action for this entry The watch process procAlive configuration file directive automatically creates the following boolean expression for the entry hrSWRunStatus 4 If the status of the process as determined by the Host Resources Running Software table equals invalid 4 or if the process stops running the agent sends a processStop SNMP trap If a
258. ervent OBJECT IDENTIFIER traps 19 procGroupChangeTrap TRAP TYPE ENTERPRISE sysmgmt VARIABLES pgmonIndex pgmonDescr pgmonFlags pgmonNumProcs pgmonProcRegkExpr pgmonRowStatus pgmonPIDList pgmonStatusList DESCRIPTION Membership in a process group has changed For example members have joined or left the group or have changed 19 eHealth SystemEDGE User Guide 230 e Chapter 8 Private Enterprise Traps SNMP Trap Format The SystemEDGE agent sends Trap PDUs to the SNMPv1 Trap port UDP 162 Figure 20 shows the structure of an SNMPv1 Trap PDU SNMP Trap POU Enterprise Agent eener Trap Specitic Trap Time Stamp Variable Address Object IL T alua Figure 20 Structure of SNMP Trap PDU Table 28 describes the components of the SNMP Trap PDU Table 28 Components of the SNMP Trap PDU Page 1 of 2 Enterprise System Object ID of the sender empire 546 1 1 IP address of sending host Generic trap type One of the following coldStart 0 e warmStart 1 linkDown 2 e linkUp 3 e authenFailure 4 egpNeighborloss 5 e enterpriseSpecific 6 eHealth SystemEDGE User Guide SNMP Trap Format 231 Table 28 Components of the SNMP Trap PDU Page 2 of 2 Specific trap type Enterprise specific trap type Time stamp Value of sysUptime when the trap was sent always 0 for sendtrap Variable bindings Array of MIB variables and their values eHealth SystemEDGE User Gu
259. erver messages Searching the Security Log for Failure Events The following example adds a new entry to the agent s NT Event Monitor table at table index 2 to search the Security log for Failure events that indicate login failures watch ntevent 2 0x00 Security Failure Access Failure WARNING eHealth SystemEDGE User Guide 372 e Chapter 14 Configuring Windows Event Monitoring Searching the Application Log for Specific Events The following example adds a new entry to the agent s NT Event Monitor Table at table index 3 to search the Application log for events with Event ID 277 watch ntevent 2 0x0100 Application All T 277 Event ID 277 T The flag 0x0100 adds the Event ID to the description 277 is the description field that the agent will attempt to match NOTE The backslash character is required because brackets are special characters for regular expression matching Using the edgewatch Utility to Monitor Windows Events To facilitate Windows event monitoring SystemEDGE includes the edgewatch command line utility This utility acts in a manager role to configure entries in the NT Event Monitor table and list entries that are currently in the table The edgewatch utility is located in the bin subdirectory of the SystemEDGE agent distribution NOTE Although the NT Event monitoring capability is provided on Windows only you can configure it from any supported platform using the
260. ervices eHealth SystemEDGE User Guide Systems Management MIB This chapter gives examples of management information that is available through the enterprise specific Systems Management MIB The Systems Management MIB module defines a collection of objects for managing host systems The MIB is organized into sections for the following types of information Host configuration Kernel configuration Mounted devices Users and groups Remote command execution Processes Streams Performance monitoring Interprocess communications IPC NES and RPC statistics Buffer statistics for network buffers Streams buffers I O buffer cache The MIB sections are described in more detail in the following sections The figures show sample output from a Sun SPARCstation that is running Solaris 2 5 and the SystemEDGE agent daemon sysedge For a complete description of the MIB 165 166 e Chapter 7 Systems Management MIB objects refer to the empire asn1 file in the doc subdirectory of the SystemEDGE agent distribution Some objects cannot be implemented on all platforms For information about platform specific support refer to the eHealth SystemEDGE Release Notes Host System Information You can retrieve values of the objects in the Host System group to determine the following types of information e Hostname e Operating system version and release number e CPU type e Amount of memory e Version of the SystemEDGE agent Table 15
261. es a Enter the name of the community that you want to configure as read write for example private at the following prompt Enter read write community no spaces case sensitive eHealth SystemEDGE User Guide 13 The script displays the following Setting read write community to private Press Return at the following prompt to configure a trap destination Configure a Trap Destination yes Installing SystemEDGE on HP UX Systems 79 a Enter the hostname or IP address of the trap destination for example aview empire com at the following prompt Enter trap destination IP address b Enter the trap community or press Return to configure public as a trap community at the following prompt Enter trap community public The script displays the following Adding trap community to config file Restarting SystemEDGE 14 Press Return at the following prompt to use the licenseme utility to automatically license the SystemEDGE agent License SystemEDGE via licenseme utility yes The script displays the following You will need to have access to http license concord com either directly or through a web proxy if the proxy requires authentication you will need username password for it You also need SNMP read write access to SystemEDGE You also need your licensing account username passwd a Enter sysedge at the following prompt Product choose one sysedge svcrsp xchgmod iismod apachemod oramod sgql
262. escribes how to use the SystemEDGE agent in conjunction with other SNMP agents Supporting Multiple SNMP Agents By default all SNMP agents attempt to use UDP port 161 but only a single process can bind to a given port at any one time That is only one SNMP agent can use UDP port 161 at a time If you are running multiple SNMP agents simultaneously you must develop strategies for their coexistence The following are potential solutions for enabling several SNMP agents to share UDP port 161 e Multiplex UDP port 161 among several SNMP agents usually in a master slave relationship e Execute agents simultaneously if each binds to a separate UDP port and management software is configured to communicate with them individually e Code agents to conform to every existing proprietary master subagent API This solution has an exceedingly high cost in terms of coding testing and licensing the numerous proprietary APIs 157 158 e Chapter G6 Using the SystemEDGE Agent with Other SNMP Agents The most common notion of agent multiplexing involves a master agent that is bound to UDP port 161 communicating with separate subagents or slave agents that are implementing different MIBs The master and subagents communicate using a defined protocol for registering the subagent and exchanging messages between them Several protocols exist for governing such a communication protocol between Master and subagent Agent Multiplexing For more inf
263. ese files in another directory by specifying an alternate directory through command line arguments For more information refer to Chapter 5 Starting the SystemEDGE Agent Configuration Files for Windows Systems By default the SystemEDGE agent looks for the configuration files in the SystemRoot system32 directory The SystemEDGE agent setup program installs these files into that directory automatically during the installation You do not need to copy these files manually unless you installed the SystemEDGE agent as an upgrade instead of a new installation Edit these files to match your local requirements NOTE If you installed the SystemEDGE agent as an upgrade review the new files in sysedge config to identify the latest features and then integrate them with your current configuration files eHealth SystemEDGE User Guide 90 e Chapter 2 Installing the SystemEDGE Agent SystemEDGE Agent Directories and Files This section describes the directories and files that the SystemEDGE agent installation creates Table 7 and Table 8 describe the platform specific files Table 9 describes files that are common across platforms Directories and Files for UNIX Systems Table 7 describes the directories and files that the SystemEDGE agent installation creates for UNIX systems only Table 7 SystemEDGE Directories and Files for UNIX Systems Page 1 of 2 Directory Fle Description bin Subdirectory that contains the SystemE
264. essname Specifies the regular expression used to find the PID of the process to monitor Enclose this value in quotation marks if it contains spaces or other special characters Specifies the row index to use for this monitoring entry flags Specifies the hexadecimal flags for example 0x00000001 that indicate the additional behavioral semantics of this entry interval Specifies an integer value 30 to MAXINT that indicates how often in seconds the agent should monitor the process For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds description Specifies a quoted string that is 0 to 128 characters in length and that normally contains a description of the process and attribute that are being monitored as well as a severity level for this event action Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the expression evaluates to True and a trap is sent If the string is empty the agent invokes no action for this entry eHealth SystemEDGE User Guide Using the edgewatch Utility to Monitor Processes 313 Table 45 edwatch Command Arguments Page 2 of 2 Argument Description status One of the following e active activate a row e notInService deactivate but preserve a row e destroy delete a row attribute Process attribute tha
265. ets to the Systems Management Process Monitor table and the Host Resources Running Software table assuming that queries use a valid community with read only or read write permissions respectively Performing SNMP Sets in those tables could be a potential security issue SNMP Sets can send UNIX processes signals for example KILL and can terminate processes on Windows systems Depending on the local security policies that are in effect at your site you may want to disable the agent s support for SNMP Sets in these tables For more information about these tables refer to Chapter 7 Systems Management MIB and Chapter 9 Host Resources MIB To disable support for SNMP Sets to the Process Monitor table add the following line to sysedge cf no_process_sets Performing SNMP Gets in those tables could also be a potential security issue SNMP Gets can discover the processes that are running on the underlying system Depending on the local security policies that are in effect at your site you may want to disable the agent s support for SNMP Gets in these tables For more information about these tables refer to Chapter 7 Systems Management MIB and Chapter 9 Host Resources MIB To disable support for SNMP Gets and Sets to the Process Monitor table add the following line to sysedge cf no_process_table eHealth SystemEDGE User Guide 140 e Chapter 4 Configuring the SystemEDGE Agent Monitoring Applications
266. ext The Choose Destination Location dialog box appears eHealth SystemEDGE User Guide 62 e Chapter 2 Installing the SystemEDGE Agent InstallShield Wizard Choose Destination Location Select folder where Setup will install files Concord SystemEDGE installation will create a subdirector called sysedge in the directory of your choice Default is C thus leading to creation of C sysedge If you select Browse you may choose or automatically create an alternate installation directory Destination Folder C sysedge Browse InstallShield 6 Click Next to accept the default installation directory or click Browse select the directory in which to install SystemEDGE and then click Next The recommended directory is C sysedge You must use the root directory and you must keep the sysedge directory name but you can select a different directory You can for example install eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 63 the agent in C Concord sysedge If you select a different directory make sure you install any SystemEDGE plug ins under the same directory for example in C Concord sysedge plugins The setup program copies the sysedge dll file and the sysedge cf sysedge mon and sysedge lic configuration files into the system root directory SystemRoot system32 If you are upgrading from a previous version of the SystemEDGE agent the installation does not ove
267. f the configuration file Invalid monitor table index An invalid Monitor table index was specified either in a configuration file command or through SNMP row creation to the monitor table Valid monitor table indexes must be greater than 10 Rows 1 through 10 are reserved by the SystemEDGE agent for internal use eHealth SystemEDGE User Guide 456 e Appendix A Error Messages invalid monprocess regular expression A monprocess configuration file statement contained an invalid regular expression The agent will not create the Monitor table entry and will ignore the statement The SystemEDGE agent however will continue to parse the remainder of the configuration file invalid NT event log name The Windows event log name that was supplied through the configuration file or through the command line utility was incorrect invalid NT event type The Windows event type that was supplied through the configuration file or through the command line utility was incorrect invalid number history buckets An emphistory configuration file statement contained an invalid number of history buckets The SystemEDGE agent will not create a history table entry and will ignore the statement The agent will however continue to parse the remainder of the configuration file invalid SNMP variable type X The SNMP variable type x as specified in the agent s configuration file for registry extension objects was incorrect For a list of supported
268. f the mounted file system to monitor variable name Specifies the file system variable from the Systems Management MIB devTable to monitor For example you can monitor a file system s capacity by specifying devCapacity as the variable name status One of the following e active activate a row e notInService deactivate but preserve a row e destroy delete a Monitor table row eHealth SystemEDGE User Guide 278 e Chapter 10 Configuring Threshold Monitoring edgemon Examples This section provides examples of how to use the edgemon command Monitoring 1 Minute Load Average with edgemon The following example creates an entry at index 11 in the agent s Monitor table that monitors the system s 1 minute load average for a threshold of 3 edgemon 143 45 0 12 private oid loadAveragelMin 0 11 0x00 60 absolute gt 300 Monitor L minute load average m Monitoring Hardware Interrupts with edgemon The following example creates a Monitor table entry to monitor the number of hardware interrupts on the underlying system against the threshold 1000 edgemon 143 45 0 12 private oid numInterrupts 0 14 0x00500400 60 delta gt 1000 Monitor Interrupt Rate eHealth SystemEDGE User Guide The agent creates this entry at index 14 and samples the numInterrupts variable every 60 seconds The flags field of 0x00500400 instructs the agent to modify the default Monitor table behavior as follows e 0x00000400 Instructs the agent to
269. fail 1 Create an entry in the Monitor table to monitor a particular application or process You can create an entry through monprocess through an SNMP management station or by editing the sysedge mon file in a text editor 2 Make sure that entry contains an action script That action script is responsible for restarting the application and resetting the monitor table entry for the application or process The SystemEDGE agent distributions come with an example script restartproc sh that performs this function When the process fails the monitor table entry evaluates to True sends an SNMP trap to the management system and executes the action script The action script restarts the application waits a few seconds and then calls monprocess to reinitialize the monitor table entry so that the agent will resume monitoring the new process Implementing Trap Severity Levels eHealth SystemEDGE User Guide Currently trap messages generated by the SystemEDGE agent contain many variables but not an explicit severity level However trap messages that are generated by the self monitoring tables contain an ASCII description field You can implement severity levels if they are encoded within the corresponding description string for the particular table row in question Common Problems and Questions 437 Using this approach you can assign severity levels like Critical or Warning and you can include those severity levels within the
270. failed The SystemEDGE agent could not determine file information about an action command file that is used with a NT Event Monitor table configuration file statement Consequently it sets the status of the corresponding NT Event Monitor table row to notReady sysedge using port X config file Y Upon startup UNIX versions of the SystemEDGE agent report which UDP port and configuration file they are using This message is informational only and does not represent an error condition system call ret error X The SystemEDGE agent was unable to execute a command that was specified as part of the remoteShell group functionality This error can occur when the remoteShell function is invalid or if the underlying system cannot create a sub process This agent binary is compiled for X not Y Because the SystemEDGE agent is specific to the revision of the operating system on which it runs it must often be compiled specifically for each operating system This error message indicates that a version of the SystemEDGE agent for one version of the operating system was executed on a version that is not compatible with the one for which it was compiled For example on Solaris 2 x you must use separate SystemEDGE agent binaries for versions 2 5 x and 2 6 2 7 32 bit and 2 7 64 bit For a list of binaries for each operating system refer to Chapter 19 Troubleshooting and Usage Suggestions eHealth SystemEDGE User Guide 468 e Appendix
271. fer to Chapter 16 Adding Custom MIB Objects extension variable X already in use The extension command variable specified in the configuration file is already in use Extension commands must specify a number that has already been used Check the configuration file duplicate extension command numbers and restart the SystemEDGE agent For more information about extending the SystemEDGE agent refer to Chapter 16 Adding Custom MIB Objects failed to add monitor entry index X The SystemEDGE agent failed to add a Monitor table entry This error usually results from bad parameters which are most often due to invalid intervals boolean operators object identifiers and so on Fix the monitor entry and restart the SystemEDGE agent For the correct syntax for Monitor table entry commands refer to Chapter 10 Configuring Threshold Monitoring failed to alloc anIDE struct The SystemEDGE agent failed to allocate memory for an IDE device most likely because the underlying system is low on memory The SystemEDGE agent will continue to operate failed to alloc space for monitor eHealth SystemEDGE User Guide The SystemEDGE agent failed to allocate memory for its Monitor table most likely because the underlying system is low on memory The SystemEDGE agent will continue to operate but it will not be able to perform self monitoring SystemEDGE Agent Error Messages 447 failed to create a trap session The System
272. fer to the next section Log Monitor Table Flags eHealth SystemEDGE User Guide Log Monitor Table Flags 337 Optimizing Row Creation You can use the following MIB objects with the Log Monitor table to optimize row creation Table 51 Scalar Objects for Optimizing Row Creation logmonUnusedIndex Read Only You can use this variable to optimize table row creation for the Log Monitor table Perform an SNMP Get of this variable to return an unused index number for the Log Monitor table logmonMatchDescr Read Write You can use this MIB object with the LogMonitorMatchIndex MIB object to determine the index number that corresponds to a particular entry description Perform an SNMP Set of this MIB object to cause the agent to search through entries in the Log Monitor table and place the index value of the last entry whose description matches in the LogMonitorMatchIndex MIB object logmonMatchIndex Read Only You can use this MIB object with LogMonitorMatchDescr to match a particular entry description with its index number Log Monitor Table Flags The logMonitorFlags column in the Log Monitor table is a 32 bit unsigned integer that can specify additional behavior for the corresponding Log Monitor table row By default the Log Monitor table row does the following e Attempts to reinitialize itself Sends SNMP traps e Logs matches to syslog Invokes actions if they are configured You can specify different flag
273. ffect when the system is rebooted or when the syslog deamon reads its configuration file again You can set it to do so by sending it an HUP signal Adding Self Monitoring Entries to the _sysedge mon File This appendix describes the format for the sysedge mon file which provides stable storage for the self monitoring and history tables supported by SystemEDGE agent In most cases you do not need to edit the sysedge mon file Instead you can configure these features of the SystemEDGE agent through the sysedge cf configuration file or through one of the command line utilities If you do need to edit sysedge mon use this appendix to ensure that you are using the correct file format SystemEDGE Table Backing Store On startup the SystemEDGE agent s sysedge mon file reports to the agent the state of the self monitoring tables while the agent was previously running The agent looks for sysedge mon in the etc or SystemRoot system32 directories by default when it is started unless you have specified an alternate directory and file name This monitor configuration file consists of a series of entries each describing a row in one of the self monitoring tables For descriptions of valid values and more examples refer to Chapter 10 Configuring Threshold Monitoring 493 494 e Appendix C Adding Self Monitoring Entries to the sysedge mon File NOTE Edit the sysedge mon file only when SystemEDGE agent is not running The
274. ffer pool numClusters 2 Total number of logical pages or clusters obtained from 28 the page pool freeClusters 3 Number of free clusters numDrops 4 Number of times requests for message buffers were denied numWait 5 Number of times requests for message buffers were delayed numDrain 6 Number of calls to protocol drain routines 00 eHealth SystemEDGE User Guide e SNMP Table Display Stream Buffers 183 Figure 10 shows a sample Message Buffer Allocation table Table mbufAllocTable Path 1 53 6 1 4 1 546 1 1 10 1 Rowet10 Columnea Instance mbuf Type mbuf esc mbuFAL loc i i Free list al 1 1 Dynamic data allocation 1 2 2 Packet header E Socket structure 165 4 4 Protocol control block 204 5 z Routing tables 5 E E IHF host tables 9 f H Address resolution tables 0 E E Socket name 18 a J zombie proc status Hext Fage a Stream Buffers Figure 10 Systems Management MIB Sample Message Buffer Allocation Table Use the Streams Buffer Allocation table to monitor buffer allocation and usage statistics for buffers that are used by the Steams subsystem Figure 11 shows a sample Streams Buffer Allocation table eHealth SystemEDGE User Guide 184 e Chapter 7 Systems Management MIB e SNMP Table Display Table strbufAllocTable Patht 1 3 6 1 4 1 546 1 1 10 2 1 1 Rows 8 Columns 6 peter strbufAllocindex strbufAllocSize strbufAllocCurrent strbufAl lochas strbufAllocT
275. files sysedge lic sysedge cf and sysedge mon if you installed them in a directory other than the default etc Starting the Agent Automatically at System Boot 153 Starting the Agent Automatically for Windows Systems The SystemEDGE service starts by default at system boot time To verify that the agent is set to start automatically open the Services Control Panel right click SystemEDGE and select Properties On the General tab select Automatic from the Startup type list and then click OK Starting the Agent Automatically for HP UX Systems For HP UX version systems you must run the SystemEDGE agent s sysedge script to start the agent automatically at boot time Copy this script from the config subdirectory to sbin init d and then create a symbolic link to the file by entering the following command ln s sbin init d sysedge sbin rc2 d S990sysedge If you installed the agent in a directory other than the default opt EMPsysedge you must edit sysedge to include the correct installation directory In addition you must edit sysedge to include the correct directory for the agent s three configuration files sysedge lic sysedge cf and sysedge mon if you installed them in a directory other than the default etc To run the SystemEDGE agent instead of the native HP UX agent edit the following statements in etc rc config d as described e SNMP_MASTER_START 1 to SNMP_MASTER_START 0 e SNMP_HPUNIX_STA
276. for non tabular MIB variables filesystem filesystem name variable name The word filesystem followed by the name of a mounted file system that you would like to monitor and the variable from the Systems Management MIB devTable that you would like to monitor For instance you can specify filesystem usr devCapacity monIndex Row index of the Monitor table to use for this entry Each row in the agent s Monitor table is uniquely identified by an index number Rows 1 through 10 are reserved for internal use by the agent so the monIndex value must be greater than 10 monFlags Hexadecimal flags for example 0x00000001 that specify any additional behavioral semantics for this entry monInterval Integer value 30 to MAXINT that indicates how often in seconds the monitoring should occur For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds monSampleType Either absolute or delta this value indicates whether the agent should sample the object s absolute value or take the difference between successive samples eHealth SystemEDGE User Guide Adding Entries with the monitor Directive 263 Table 34 Monitor Directive Parameters Page 2 of 2 monOperator Operator type A boolean operator that is used for evaluating the expression current value operator value The operator can be any of the following nop no operation gt greater than l
277. for write_runStatus An attempt to change the Host Resources hrRunStatus variable for a process has failed due to an invalid process ID PID Double check the PID value for that process and try management operation again bad shellOutput directory X The directory that is specified for remoteShell invocation output is invalid All output from remoteShell invocations should be placed in tmp or tmp bad shellOutput file X The designated remoteShell output file is invalid because it is either not a file for example it is a directory or it is contained in an invalid directory for example not in tmp bind failed eHealth SystemEDGE User Guide The SystemEDGE agent attempted to bind to a UDP port and failed If that UDP port is already in use another SNMP agent is already running on that system and is using that port This problem commonly occurs when multiple agents attempt to use the same UDP port for example UDP 161 The Internet Assigned Numbers Authority IANA has reserved UDP 1691 for the SystemEDGE agent You can configure the SystemEDGE agent to use that port by specifying it on the command line through the p option SystemEDGE Agent Error Messages 441 block size for X is O using 1K The SystemEDGE agent failed to determine a file system s underlying block size and is using 1000 bytes as a default block size for calculations in the Systems Management MIB Mounted Devices table cant open kmem The Sys
278. fore no NT Event Monitor table entry was created Command line Utility Error Messages 481 Set to ntEventMionTable failed This message indicates that nteventmon failed to perform an attempted SNMP Set operation to create delete or modify a row in the SystemEDGE agent NT Event Monitor table The requested action therefore was not performed This error can result from an invalid community string or a community string without write access SNMP Operation failed An nteventmon SNMP operation failed This error may or may not indicate that nteventmon failed to perform its intended action that depends on any other messages that are displayed by nteventmon target host is not an NT system nteventmon first attempts to verify that the target machine is running Windows This message indicates that the target system is not running Windows and therefore does not support the NT Event Monitor table unknown command The command that was passed to nteventmon on the command line was invalid No action therefore was performed sendtrap Error Messages This section describes error messages that may be generated by the sendtrap utility cant resolve address for The address or hostname that was provided to sendtrap could not be resolved to a valid IP address so the requested action was not performed Verify that the hostname has a valid address through tools like host or nslookup eHealth SystemEDGE User Guide 482 e Appendix A
279. ftware distributions into the CD ROM drive and mount it using SAM 1M as cdrom 3 Run the swinstall utility by entering the following usr sbin swinstall s cdrom sysedge hpux sysedge dpt EMPsysedge By default the swinstall utility 4 Run the installation script from the opt EMPsysedge places the software in the opt directory by entering the following commands directory cd opt EMPsysedge Install eHealth SystemEDGE User Guide 76 e Chapter 2 Installing the SystemEDGE Agent When you run the installation script you must enter valid values for all prompts If you enter invalid values or press Enter at a prompt that requires a value and does not offer a default value the script will not complete properly If the script generates an error message or is unable to complete you must run the script again and specify valid values for all prompts The installation script displays the following message Concord SystemEDGE Agent Post Installation Starting Determining platform specific information Copying config monitor license files to etc Copying startup file to sbin init d and making link into fSsbin7 ro2 d You can change the configuration information after the installation if desired for more information refer to Chapter 4 Configuring the SystemEDGE Agent The post installation script also enables automatic licensing of the agent For information about additional ways to license the agent refer t
280. g Process Group Monitoring from the Configuration list and clicking the the Configuration icon For more information refer to the AdvantEDGE View Web Help Figure 48 shows a sample AdvantEDGE View Process Group Monitor table Index Description ntrvafReatxr User Group Figs action gesug Num Prove 9 Monitor NFS Server 60 infs admin any ox 10b no action E 2 ko Monitor Web Server 60 http lami any Oxa ino action lo 11 Monitor 55H Server 30 sshd fany tany Oxo no action o 12 Monitor FTP Server 30 fod admin any Oxo no action Q lo 413 Monitor all 60 le any any lxb no action 5 35 14 Monitor RFC daemons 60 rpc any tany Oxa no action Q 1 Figure 48 Sample AdvantEDGE View Process Group Monitor Table Assigning Entry Rows for the Process Group Monitor Table The pgmonIindex column of the Process Group Monitor table acts as a key field or row index to distinguish rows in the table Rows 1 through 10 are reserved for internal use by the SystemEDGE agent Users can configure rows in the range of 11 to MAXINT For more information about reserving blocks of rows refer to Reserving Blocks of Rows on page 258 eHealth SystemEDGE User Guide 328 e Chapter 12 Configuring Process Group Monitoring Configuring the Process Group Monitor Table You can control which processes and process attributes the SystemEDGE agent monitors by adding deleting or modifying the entr
281. gement MIB but some of the MIB objects within this MIB module are not supported by the underlying Windows operating system In addition some of the UNIX specific MIB objects are not applicable to Windows Those objects therefore cannot be implemented by the Windows version of the agent eHealth SystemEDGE User Guide 200 e eHealth SystemEDGE User Guide Chapter 7 Systems Management MIB The following Systems Management MIB objects are not supported by Windows system hostid devTable devTfiles devTable devFfiles devTable devMaxNameLen devTable devFstr kernelConfig serialNumber kernelConfig maxInode kernelConfig maxFiles kernelConfig maxClist kernelConfig maxMemPerProc kernelConfig openMaxPerProc kernelConfig posixJobCtrl kernelConfig posixVersion bootconf streams userTable userUID user Table userGID userTable userShell processTable processFlags processTable processUID processTable processGID processTable processRSS processTable processParentPID processTable processInBlks processTable processOutBlks processTable processMsgsSent processTable processMsgsRecv processTable processSysCalls Windows Specific Groups 201 processTable processMinorPgFaults processTable processNumSwaps processTable processVolCtx processTable process InvolCtx performance except kernelperf kernelperf diskWaitNum kernelperf pageWaitNum kernelperf swapActive kernelperf sleepActive kernelperf numTraps kernelperf numPageReclaims kernel
282. gent To do so comment out the AIX agent s invocation in etc rc tcpip by adding a pound sign at the beginning of the following lines Start up the Simple Network Management Protocol SNMP daemon start usr sbin snmod Ssro ronning Using the SystemEDGE Agent with the Digital UNIX or Tru64 SNMP Agent Digital UNIX and Tru64 systems ship with an extensible agent and subagents that provide support for MIB II and for the Digital and Tru64 implementation of the Host Resources MIB The Master subagent interface is based on a proprietary API that the SystemEDGE agent does not support Take either of the following coexistence approaches e Run the agents together on the system running the SystemEDGE agent on port UDP 1691 Turn off or disable the Digital or Tru64 Master subagent and run the SystemEDGE agent on port UDP 161 eHealth SystemEDGE User Guide 164 e Chapter 6 Using the SystemEDGE Agent with Other SNMP Agents Using the SystemEDGE Agent with the Compaq Insight Manager You can run the SystemEDGE agent and the Compaq Insight Manager CIM on the same system When you are deploying SystemEDGE agents from AdvantEDGE View to a system that includes CIM AdvantEDGE View stops the following CIM services e Compaq Foundation Agent Compaq Web Agent e Compaq Storage Agent e Compaq Server Agent e Compaq NIC Agent After the SystemEDGE agent and eHealth AIMs are deployed AdvantEDGE View restarts all of these s
283. gent will be unable to support MIB II related statistics but should otherwise operate normally caught SIGHUP The SystemEDGE agent caught a UNIX hang up signal and is continuing to operate normally config file error in subprogram_user_name directive The SystemEDGE agent configuration file contains an error in the subprogram directive The directive will be ignored Fixing the statement and restarting the agent will correct the problem config syntax error line X The SystemEDGE agent has encountered a syntax error in its configuration file at line x The offending line will be ignored and the rest of the configuration file will be parsed Could not find a valid license for machine X The SystemEDGE agent could not find a valid license for the system on which it is operating Check that the SystemEDGE agent license file is in the correct location and contains a valid license On Windows systems the configuration file is located in the system root directory SystemRoot system32 On UNIX systems the SystemEDGE agent looks for the file in the etc directory couldn t fork sub shell The SystemEDGE agent could not create or invoke a sub shell to process a remoteShell operation If the system process table is full additional processes cannot be created eHealth SystemEDGE User Guide SystemEDGE Agent Error Messages 443 counterType X not supported Entry will not be added The SystemEDGE agent could not support regist
284. ges to notify you of possible security violations When the agent starts or after rows have been added to the Log Monitor table it checks the status of stats each log file for its current length and last access time Thereafter the agent periodically stats each log file for additions or modifications 333 334 e Chapter 13 Configuring Log File Monitoring since the last status check If the log file has changed the agent scans only the changes not the entire log file to see if there is a match for the specified regular expression If the agent finds a match it sends the enterprise specific logMonMatch SNMP trap to the configured NMS and executes the specified action for the row if the action field is not null For more information about the logMonMatch trap refer to logMonMatch Trap on page 222 Log Monitor Table For each entry the Log Monitor table provides the following information e Name of the log file that the agent is monitoring for a particular regular expression e Number of times a trap has been sent because a match was found e Time at which the last trap was sent Log entry that caused the last match Figure 49 shows sample entries for the Log Monitor table SNMP Table Display Table logMonitorTable Path 1 5 6 1 4 1 546 11 1 1 Rowst4 Columns 7 logMonitorLogFile logMonitorRegularExpression logMonitorNumberTraps logMonitorLastTrap logMonitorLastMatch logMonitorSta fusr adm sulog su 0
285. group membership and tracks process statistics even after an individual process has left the group Table 46 Columns of the Process Group Monitor Table Page 1 of 4 xe Pens oon O pgmonIndex Read Only Integer 1 to MAXINT that indicates the row index for this entry Index values must be unique but they do not need to be contiguous pgmonDescr Read Write Quoted string that is 0 to 128 characters in length and that normally contains a description of the entry and who created it pgmonInterval Read Write Integer value 1 to MAXINT that indicates how often in seconds the agent should sample the variable For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds eHealth SystemEDGE User Guide The Process Group Monitor Table 321 Table 46 Columns of the Process Group Monitor Table Page 2 of 4 Column Name Permissions _ Description Write caa ea expression to apply when the agent is attempting to match processes by name pgmonFlags Read Write Integer flags value that dictates the behavior of each entry The default is 0x00 For more information about this field refer to Process Group Monitor Table Flags on page 325 pgmonNumProcs Read Only Current number of processes in the process group that this entry is tracking A process belongs to the process group if its name and possibly its arguments match the regular expression tha
286. gt hrDeviceSerialPort zsl Zilog 8530 SCC Serial Communications Driver null running 2 gt hrDeviceOther sbus0 Main Memory and Bus I 0 Space null running 2 gt hrDeviceParal lelPort bpp0 Bidirectional parallel port null running 2 gt hrDeviceNetwork FORE sba 2000 Fore ATM SBus Adapter null unknown lt 1 hrDeviceNetwork SUNW DBRIeO Dual Basic Rate ISDN Interface and Speaker null unknown lt 1 gt hrDeviceVideo egsix0 Accelerated 8 bit Color Frame Buffer null running lt 2 el SSS Ef OK esta Figure 24 Sample Host Resources Device Table eHealth SystemEDGE User Guide 238 e Chapter 9 Host Resources MIB Inventory Tracking and Asset Management The hrDeviceTable is especially useful for inventory tracking and asset management Instead of manually opening and inspecting each workstation on your network to determine the number and types of ethernet cards serial devices audio devices disk storage devices and so on you can use your central management system to retrieve the hrDeviceTable from each of the systems on your network Processor Table eHealth SystemEDGE User Guide The hrProcessorTable lists device specific information about the system s processors If the system contains only a single processor the hrProcessorTable includes only one row The columns of the hrProcessorTable provide the product ID of the firmware that is associated with the processor if such an ID has been assigned and made available by the
287. guese da 48 SNMP Om eS ss cane adeeeecne eee ceems obs ieaiai 48 Installing the SystemEDGE Agent 31 Installing SystemEDGE on Solaris Systems 52 System Requ ireMentS ss isiwdsceeetrdest dinee derki das 52 Adding the SystemEDGE Agent Package 52 Installing SystemEDGE in a Non Default Directory e a E E PE TENET N 58 Installing SystemEDGE on Windows Systems 59 System Reguite menis sriressirreina sitean keadaan 59 Installing the Software with InstallShield 60 Installing the Software from the Command Line 74 Installing SystemEDGE on HP UX Systems 75 System REQUITCMICING 415 45 40s0e4 o4des eee Genoese Xan 75 Installing the Software 0 cece cece eee eens 75 Installing SystemEDGE on Linux Systems 80 System REQGUITCMICING 2460204 t4eb end taveeue Ens Saken Es 80 Installing the Software 0 ccc eee e eee eeees 81 Installing SystemEDGE on AIX Systems 02 5 82 Systemi REQUITCHICHS 24 cx04 tous eedecaneaesetewe aes 82 Installing the Software lt 4 2040d cnuewaiusaeeedigdatends 83 Installing SystemEDGE on Digital UNIX and Tru64 Systems 84 System Requirements 42s cccatawdseven aootedscietdeeys 84 Installing the Software 0 cece cece eee eee eee 84 Reviewing the Configuration Files 0 c eee eee eee 86 Configuration Files for UNIX Systems 89 Configuration Files for Wi
288. gular expression was logged to the file LogMonitorLastTrap Read Only Time based on sysUpTime at which the agent last sent a trap for this entry LogMonitorLastMatch Read Only Last log file entry that matched the regular expression this variable is updated each time a match occurs eHealth SystemEDGE User Guide 336 e Chapter 13 Configuring Log File Monitoring Table 50 Columns of the Log Monitor Table Page 2 of 2 LogMonitorStatus Read Write SNMPv2 RowStatus one of the following e active 1 e notInService 2 notReady 3 LogMonitorLogFileSize Read Only Current size in bytes of the file that is being monitored LogMonitorLogFileLastUpdate Read Only Time that the file was last updated LogMonitorDescr Read Write Quoted string that is 0 to 128 characters in length and normally contains a description of the file being monitored as well as a severity level for this event LogMonitorAction Read Write Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the regular expression is matched and a trap is sent If the string is empty the agent invokes no action for this entry LogMonitorFlags Read Write Unsigned integer flags value indicating additional behavior that this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field re
289. h the agent can report on processes that are consuming the most CPU resources at any given time You can use Top Processes to detect and isolate the CPU dominating processes Then you can reallocate resources to ensure optimal system and eHealth SystemEDGE User Guide 34 e Chapter 1 Introduction application availability and performance The Top Processes AIM ships with the SystemEDGE agent and does not require a separate license You can enable this AIM during the SystemEDGE agent installation Tracking Assets You can use SystemEDGE to automate asset tracking and provide an up to date picture of your installed hardware and software SystemEDGE can determine whether your systems are properly configured and whether they include the current patches and service packs This information can help simplify system management improve performance and reduce security risks For more information about tracking assets refer to Inventory Tracking and Asset Management on page 242 Supporting Custom MIB Objects The SystemEDGE agent enables you to create your own scalar MIB objects for customized management You can configure SystemEDGE with each MIB object s number and type and the name of a script or program to execute when the new MIB variable is queried or set For more information refer to Chapter 16 Adding Custom MIB Objects Supporting Windows Registry and Perfmon Extensions eHealth SystemEDGE User Guide You can also
290. have been returned to CA or destroyed EXCEPT AS OTHERWISE STATED IN THE APPLICABLE LICENSE AGREEMENT TO THE EXTENT PERMITTED BY APPLICABLE LAW CA PROVIDES THIS PRODUCT AS IS WITHOUT WARRANTY OF ANY KIND INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT IN NO EVENT WILL CA BE LIABLE TO THE END USER OR ANY THIRD PARTY FOR ANY LOSS OR DAMAGE DIRECT OR INDIRECT FROM THE USE OF THIS PRODUCT INCLUDING WITHOUT LIMITATION LOST PROFITS BUSINESS INTERRUPTION GOODWILL OR LOST DATA EVEN IF CA IS EXPRESSLY ADVISED OF SUCH LOSS OR DAMAGE The use of this Product and any product referenced in the Documentation is governed by the end user s applicable license agreement The manufacturer of this Product is CA This Product is provided with Restricted Rights Use duplication or disclosure by the United States Government is subject to the restrictions set forth in FAR Sections 12 212 52 227 14 and 52 227 19 c 1 2 and DFARS Section 252 227 7013 c 1 ii as applicable or their successors All trademarks trade names service marks and logos referenced herein belong to their respective companies Copyright 2006 CA All rights reserved Table of Contents Chapter 1 Preface 23 PA e ga ee oy cee cee 6 he occu eee 46s ET ee nees 24 About This Guide 3 ca tess cc bent on Ge rose ee geent ciao eos 24 Revision Information 2 25 0 0 4e0sedtaweees tetetete
291. he Root File System 271 Monitoring Space on the usr File System 272 Monitoring the Number of Processes 45 274 Using the edgemon Utility to Monitor Thresholds 274 edgemon Commands for Threshold Monitoring 276 edgemon Examples coc cre dedkevennesaaeeaeeeaeenned 278 Removing Threshold Monitoring Entries 279 Removing Entries from the sysedge cf File 279 Removing Entries with the edgemon Utility 279 Removing Entries Manually 00 ee eee 280 eHealth SystemEDGE User Guide Chapter 11 Chapter 12 Table of Contents e 11 Configuring Process and Service Monitoring 281 Monitoring Processes and Windows Services 281 Monitoring Windows Services 2 eee eee eeee 281 Sample Process Monitor Table Entry 282 The Process Monitor Table s c2e 8 taececheeneiacaee eres 283 Columns of the Process Monitor Table 284 Process AMIDES sats ceed owe snen anes deeuepace ewes 287 Optimizing Row Creation 0 e ee eee eee eee 289 Process Monitor Table Flags 0 0c cece eee eee ee 289 Process Monitor Table Actions 00 c eee eee 296 Viewing the Process Monitor Table with AdvantEDGE VIEW a 0 saqemnaa sen dades wy tas eee ees bards 298 Assigning Entry Rows for the Process Monitor Table 298 Configuring the Process Monito
292. he edgewatch commands for the NT Event Monitor table add ntEventMonIndex ntEventMonFlags EventMonLog ntEventMonTypeFilter ntEventMonSrcFilter ntEventMonDescFilter ntEventMonDescr ntEventMonAction setstatus ntEventMoniIndex status delete ntEventMonIndex List eHealth SystemEDGE User Guide 374 Chapter 14 Configuring Windows Event Monitoring Table 69 describes the parameters of the ntevent commands Table 69 Parameters of the ntevent Commands Page 1 of 2 ntEventMonIndex Row in the NT Event Monitor table Rows are indexed starting at 1 An index of 0 is not permitted Because SNMP does not include a Create PDU type new table entries are created as side effects of setting the columnar values for non existent rows Therefore this value is required for add operations in order to specify the index of an unused row to use for row creation ntEventMonFlags Hexadecimal flags for example 0x00001 that direct the additional behavior for this entry ntEventMonLog Event log to monitor One of the following Application System Security DirService for Directory Service DnsServer for DNS Service FileRepService for File Replication Service ntEventMonTypeFilter Event type to match for this entry The following are valid types Error Warning Information Success Failure All Type All indicates that all event types should match ntEventMonSrcFilt Regular expression to apply when scanning the Event Source at
293. hen set up threshold monitoring for the logFileSize x variable where x is the artificial expression For example do the following 1 Create a log file monitoring entry as follows logmon 10 Monitor Log File Size This example is for a Linux var log messages system For Solaris specify Menus aono var adm messages and for oe HP UX specify var adm syslog syslog log Oxa active eHealth SystemEDGE User Guide This example is for a Linux system For Solaris specify var adm messages and for HP UX specify var adm syslog syslog log Recommendations for Log File Monitoring 355 2 Create a threshold monitoring entry that monitors the tenth entry in the Log Monitor table logMonitorLogFileSize 10 or 1 3 6 1 4 1 546 11 1 8 10 and sends a trap when the log file is larger than 1048576 monentry FAD 60 absoluteValue Lao ele ale ick OA Og gO gt 1048576 active 0x8 Rotating Log Files When you are using log files with rotating non static names use symbolic links to point a static file name to the current file name Use scheduled scripts to update the links or the SystemEDGE log file monitoring entries to match the current log file name eHealth SystemEDGE User Guide Configuring Windows Event Monitoring This chapter explains how to use the SystemEDGE agent to monitor Windows event logs for regular expressions NOTE This chapter is relevant only for Windows versions of th
294. hows the composition of the Monitor Table flags field monFlags c se bits network Byte order ____________ 12 bits for flag value 12 bits table specitic flags amp bits global flags CeO HHH gt Oe ff AHH OOD FHF gt KIQ EE THE ChGHRARAROO gt OHARRA f eHealth SystemEDGE User Guide Figure 31 Monitor Table Flags The flags value consists of three fields Field 1 Common table flags defined for the self monitoring tables of the Systems Management MIB This portion is the low order 8 bits of the flag Figure 32 identifies and defines the individual bits in this field Field 2 Table specific flags that are defined separately for each of the self monitoring tables This field defines the next 12 low order bits after the common table flags Figure 33 on page 253 defines these 12 bits for the Monitor table Field 3 Reserved 12 high order bits for an integer value for use with table specific flags This field includes flags that are specific to the Monitor table Monitor Table Flags 253 The following sections explain each flag bit You can combine these flag values through a logical OR operation Figure 32 shows common flags for the monitoring tables Cree G0 OO Gla QS cal One Ober Do not execute actions Do not send SNMP traps Do not attempt to remitialize this entry Do not record events m syslog Keep sending entry not ready SNMP traps Do not pass System EDGE arguments to act
295. icating that the agent does not implement the object type associated with this column or that there is no conceptual row for which this column would be accessible in the MIB view used by the retrieval As such the management station can not issue any management protocol set operations to create an instance of this column If the value associated with the status column is notReady then the management station must first deal with all noSuchInstance columns if any Having done so the value of the status column becomes notInService and we proceed to interaction 4 Interaction 4 Making the Conceptual Row Available Once the management station is satisfied with the values associated with the columns of the conceptual row it issues a management protocol set operation to set the status column to active If the agent has sufficient information to make the conceptual row available for use by the managed device the management protocol set operation succeeds a noError response is returned Otherwise the management protocol set operation fails with an error of inconsistentValue NOTE A conceptual row having a status column with value notInService or notReady is unavailable to the managed device As such it is possible for the managed device to create its own instances during the time between the management protocol set operation which sets the status column to createAndWait and the management protocol set operation which sets the status col
296. ide Host Resources MIB This chapter describes the management information that is available through the IETF Host Resources MIB RFC 1514 NOTE The examples in this chapter do not describe the entire Host Resources MIB For a description of the entire MIB refer to the hostmib asn1 file which is included in the SystemEDGE agent distribution The Host Resources MIB defines a set of objects that can manage host computers which are independent of the operating system network services or any software application The objects defined in the Host Resources MIB are common across many computer system architectures Figure 21 shows the overall organization of the Host Resources MIB 233 234 e Chapter 9 Host Resources MIB MIB SNMP Graph Configuration Help Poe a interfaces 2 hrSystem 1 hrStorageTypes 1 N hrStorage t2 lt hrStorageTable 3 hrDeviceTypes 1 mib 2 1 hrDeviceTable 2 _ _ hrDeviceEntry 1 hrProcessorTable 3 hrProcessorEntry 1 aN hrNetworkTable 4 hrNetworkEntry 1 Sr hrDevice 3 hrPrinterTable 5 hrPrinterEntry 1 hrDiskStorageTable 6 hrDiskStorageEntry 1 hrPartitionTable 7 hrPartitionEntry 1 hrFSTable 8 _ _ _ hrFSEntry 1 hrFSTypes 9 hrSWRun 4 gt _ _ hrSWRunTable 2 hrSWRunEntry 1 hrSWRunPerf 5 hrSWRunPerfTable 1 hrSWRunPerfentry 1 hrSWInstalled 6 hrSWInstalledTable 3 hrSWI
297. ier varies for each conceptual row In some cases the instance identifier is semantically significant e g the destination address of a route and a management station selects the instance identifier according to the semantics In other cases the instance identifier is used solely to distinguish conceptual rows and a management station without specific knowledge of the conceptual row might examine the instances present in order to determine an unused instance identifier This approach may be used but it is often highly sub optimal however it is also a questionable practice for a naive management station to attempt conceptual row creation Conceptual Row Creation 517 Alternately the MIB module which defines the conceptual row might provide one or more objects which provide assistance in determining an unused instance identifier For example if the conceptual row is indexed by an integer value then an object having an integer valued SYNTAX clause might be defined for such a purpose allowing a management station to issue a management protocol retrieval operation In order to avoid unnecessary collisions between competing management stations adjacent retrievals of this object should be different Finally the management station could select a pseudo random number to use as the index In the event that this index was already in use and an inconsistentValue was returned in response to the management protocol set operation the
298. ies in the Process Group Monitor table You can configure the Process Group Monitor table in one of these ways Dynamically Use SNMP commands from a management system such as AdvantEDGE View to modify the table For more information refer to the next section Dynamic Configuration During Operation At start up initialization Specify the process attributes to monitor through the agent s configuration file sysedge cf For more information refer to Initial Configuration During Startup on page 329 Dynamic Configuration During Operation The SystemEDGE agent uses the SNMPv2 SMI Row Status textual convention for creating deleting and modifying rows in the table For more information about the Row Status textual convention refer to Appendix E eHealth SystemEDGE User Guide You can use your NMS platform to issue SNMP Set request messages to the SystemEDGE agent to modify the entries in the Process Group Monitor table Each time a Set request successfully modifies the table the agent updates the sysedge mon file to record the changes so that the agent starts up with the same Process Group Monitor table configuration it had when it was stopped That is the agent overwrites the etc sysedge mon or SystemRoot system32 sysedge mon configuration files every time the Process Group Monitor table is modified Any changes made during the operation of the agent are preserved in this file across agent and system restarts
299. ime Number of seconds the thread has been running ntThreadPriorityBase Base priority level ntThreadPriority Current priority level ntThreadWaitReason Reason that the thread is waiting executive free page page in user request virtual memory and so on ntThreadStartAddr Starting virtual address ntThreadState Current state ready running wait terminated and so on ntThreadID System wide unique ID number for the thread NT Registry Group The Windows registry is a The NT Registry group enables you to query the Windows database repository for registry You can determine if your registry is in danger of information about the system s growing larger than the size limit set for it by querying the configuration for hardware user oe following two objects accounts and applications e ntRegistryCurrentSize which provides the current size of the registry in MB e ntRegistrySizeLimit which provides the size limit in MB that is defined for the registry eHealth SystemEDGE User Guide 192 e Chapter 7 Systems Management MIB NT Service Group Windows provides several programs that run as Windows services The NT Service group provides detailed status information for each configured service on the system including the following e Service name e Path to service executable e Start type e Parameters e State e Object name Table 22 describes the NT Service group MIB objects Table 22 NT Service Group MIB Object
300. ime reinitialization fails 0x00000020 Do not pass SystemEDGE arguments to action scripts or programs SystemEDGE normally passes default action parameters that indicate the trap type description field and so on This flag disables the passing of those arguments For more 0x00000010 Send continuous monitorEntryNotReady traps for this entry each time the agent attempts to reinitialize monitoring and fails to query the desired MIB object The agent s default behavior is to send a single monitorEntryNotReady trap when a MIB object it is monitoring ceases to exist and then to attempt periodically to reinitialize the entry Enabling this feature causes the agent to send an additional information about action parameters refer to Monitor Table Actions on page 255 0x00000040 Do not send notReady traps for this entry 0x00000100 Send a monitorClear trap for this entry when the threshold monitor expression transitions from True to False eHealth SystemEDGE User Guide Monitor Table Actions 255 Table 32 Monitor Table Flags Page 2 of 2 Fag Descrtion 0x00000200 Send monitorEvent traps only on the xth consecutive event Once the xth event occurs the agent sends monitor traps for each subsequent True expression evaluation If the threshold expression transitions from True back to False the row resets itself and the agent begins counting subsequent events at zero This flag also applies to action execution You can specify the
301. imod b Enter the type of license you are requesting at the following prompt License Type choose one eval permanent usage based partner c Enter the IP address of the Web proxy server if applicable at the following prompt Web HTTP proxy server none eHealth SystemEDGE User Guide 80 e Chapter 2 Installing the SystemEDGE Agent d Enter the proxy user name if applicable at the following prompt Web HTTP proxy username none e Enter the password for that proxy user if applicable at the following prompt Web HTTP proxy password none f Enter the user name for the Web licensing account at the following prompt Web Licensing Account Username g Enter the password for the Web licensing account at the following prompt Web Licensing Account Password h Enter your name at the following prompt Your Name The installation script displays the following licenseme licensing for host 127 0 0 1 was successful Concord SystemEDGE Agent Installation complete Installing SystemEDGE on Linux Systems This section describes how to install the SystemEDGE agent on Linux systems See the Preface for a list of supported systems and versions System Requirements Before you begin installing the agent verify that your system meets the following requirements Intel or Intel compatible chipset e CD ROM drive At least 8 MB RAM At least 4 MB free disk space eHealth SystemEDGE User Gui
302. indows 59 interprocess communication deleting 181 tracking 180 K Kernel Configuration group Systems Management MIB 168 Performance group Systems Management MIB 178 L license key email request 110 example 106 licenseme utility 109 licenseutil pl utility 112 licensing e mail request 110 license key 106 licenseme utility 110 licenseutil pl utility 112 obtaining a license key 108 overview 105 public key 105 troubleshooting 429 Web based form 111 Linux installing SystemEDGE 80 platform support 23 Index e 535 removing SystemEDGE 102 system requirements 80 Linux free memory configuring support 145 enabling in sysedge 145 listing entries History Control table 389 Log Monitor table 348 Live Health 42 log files monitoring 141 333 Log Monitor table actions 341 adding entries sysedge mon 506 AdvantEDGE View display 342 columns 335 configuring 343 default action parameters 340 description 335 examples adding an entry 348 deleting entries 349 disabling entries 349 listing entries 348 monitoring log files 507 searching for pop connection attempts 344 searching for su attempts 345 flags 337 monitoring log files 141 overview 204 333 removing entries 349 sample sysedge mon entries 507 Systems Management MIB 204 watch logfile directive 343 logfileaction sh file 96 logging action commands 263 agent operating messages 155 eHealth SystemEDGE User Guide 536 e ndex daemon messages 491 syslog messages
303. ines the columns of the Monitor table For a complete description of the Monitor table and its fields refer to the empire asn1 file located in the doc subdirectory of the SystemEDGE agent distribution Table 30 Columns of the Monitor Table Page 1 of 4 monIndex Read Only Integer 1 to MAXINT that indicates the row index for this entry Rows 1 through 10 are reserved for the agent s internal use the index for additional rows must fall in the range of 11 to MAXINT monDescr Read Write Quoted string that is 0 to 128 charactersin Default Entry length and that normally contains a description of the object that is being monitored as well as a severity level for this event eHealth SystemEDGE User Guide 248 e Chapter 10 Configuring Threshold Monitoring Table 30 Columns of the Monitor Table Page 2 of 4 n E eHealth SystemEDGE User Guide Integer value 30 to MAXINT that indicates T often in seconds the agent should monitor the variable For example the value 30 instructs the agent to monitor this entry every 30 seconds This value must be a multiple of 30 seconds Either absoluteValue 1 or deltaValue 2 this value indicates whether this entry should sample the object s absolute value or take the difference between successive samples For example when monitoring counter variables use deltaValue because it describes the rate of change When monitoring gauges use absoluteValue because it describes the
304. ing Log File Monitoring Security Issues with MIBs MIB groups within the Host Resources and Systems Management MIBs may permit access to information that is deemed inappropriate by local system policies Before you deploy the SystemEDGE agent examine these MIBs to ensure eHealth SystemEDGE User Guide 422 e Chapter 18 Deploying the SystemEDGE Agent eHealth SystemEDGE User Guide that they are not violating local security policies For more information about the Systems Management and Host Resources MIBs refer to Chapter 7 Systems Management MIB and Chapter 9 Host Resources MIB In particular verify the settings for access to users groups and Who Table information as well remote shell support You can turn off support for these capabilities through the SystemEDGE agent configuration file sysedge cf For more information refer to Configuring Support for User and Group Information on page 133 and Configuring Support for Who Table Information on page 132 Betas roubleshooina and Usage Suggestions This chapter presents helpful tips for using the SystemEDGE agent For explanations of the error and warning messages that the SystemEDGE agent and its associated utilities provide refer to Appendix A For the most current information refer to the eHealth Support Web site at http support concord com You can also send license requests to productlicensing ca com Using diagsysedge exe You
305. ing Master agent 153 stopping Master agent 150 supported registry data types 405 system requirements 59 unsupported MIB objects 199 writing extension scripts 397 eHealth SystemEDGE User Guide
306. ions Do not send any notEeady traps Figure 32 Common Table Flags Low Order 8 Bits Figure 33 shows the flags that are specific to the Monitor table Qo OR OHH GnG DOAJ DlH CDRH DA D LNL H send Monitor Clear traps for this entry send traps tor this entry only atter consecutive events have occurred Send up to A corsecutive traps for this entry Figure 33 Monitor Table Specific Flag Bits eHealth SystemEDGE User Guide 254 e Chapter 10 Configuring Threshold Monitoring Table 32 describes the Monitor Table flags Table 32 Monitor Table Flags Page 1 of 2 a 0x00000001 Do not execute actions for this entry 0x00000002 Do not send SNMP traps for this entry This flag bit overrides any other flag bit with respect to traps 0x00000004 Do not attempt to reinitialize this entry By default the SystemEDGE agent periodically tries to reinitialize this entry by attempting to query the MIB object it is monitoring Note Setting this bit disables automatic reinitialization 0x00000008 Do not log events for this entry through the syslog facility Setting this bit does not affect trap sending or threshold monitoring but it does prevent the event from being logged through syslog On Windows systems the agent does not log the event to the agent s log file sysedge log Disabling event logging is useful when events occur frequently or when a particular entry is used as an agent heartbeat monitorEntryNotReady trap each t
307. ipt displays the following Setting read only community to public Press Return at the following prompt to configure a read write community Configure a read write community string yes a Enter the name of the community that you want to configure as read write for example private at the following prompt Enter read write community no spaces case sensitive eHealth SystemEDGE User Guide 96 e Chapter 2 Installing the SystemEDGE Agent 12 13 The script displays the following Setting read write community to private Press Return at the following prompt to configure a trap destination Configure a Trap Destination yes a Enter the trap destination IP address for example aview empire com at the following prompt Enter trap destination IP address b Enter the trap community or press Return to configure public as a trap community at the following prompt Enter Trap community public c Enter the trap community for example public at the following prompt Enter trap community public The script displays the following Adding trap community to config file Restarting SystemEDGE Press Return at the following prompt to use the licenseme utility to automatically license the SystemEDGE agent License SystemEDGE via licenseme utility yes The script displays the following You will need to have access to http license concord com either directly or through a web proxy if the proxy req
308. istributed with the agent extensionUomainNamet1 extensionnNisServerte extensionGroup 14 extensionMotd 4 extensionPing sl Figure 56 Sample Extension Group Features of the Extension Group eHealth SystemEDGE User Guide The Extension Group of the Systems Management MIB is located at OID 1 3 6 1 4 1 546 14 This group provides space for 2 user defined scalar MIB variables These new variables are numbered 1 through 2 and are referenced as any other scalar MIB object For example extension object 1 is referred to in Get and Set request messages as 1 3 6 1 4 1 546 14 1 0 In all cases extension variables use the object instance identifier of 0 An extension variable can be any valid base SNMP type including the following Integer e Counter e Gauge e Octetstring e TimeTicks e Objectld IpAddress You can specify variables as Read Only or Read Write Configuring Extension Variables 393 NOTE The SystemEDGE agent logs extension command invocations at syslog level LOG_DEBUG It logs extension command invocation errors at syslog level LOG_WARNING For more information about configuring the syslog utility refer to Appendix B For more information about starting the agent with its debugging options turned on refer to Chapter 5 Starting the SystemEDGE Agent Configuring Extension Variables You can configure extension variables in the SystemEDGE agent configuration file sysedge cf
309. iter process group for A processes Monitor Windows NT service instead of process Do not perform any processStart processing Figure 40 Process Monitor Table Specific Flags Table 40 describes the Process Monitor table flags Table 40 Process Monitor Table Flags Page 1 of 4 Flag Desorption 0x00000001 Do not execute actions Do not execute actions for this entry this Do not execute actions for this entry Do not send SNMP traps for this entry This flag bit overrides any other flag bit with respect to traps 0x00000004 Do not attempt to reinitialize this entry By default the agent periodically tries to reinitialize this entry by scanning the process table to determine the new process ID if the target process has been restarted Setting this bit disables automatic reinitialization 0x00000008 Do not record events for this entry in the syslog facility Setting this bit does not affect trap sending or threshold monitoring It prevents the event from being logged through syslog only On Windows systems it prevents logging events to the agent s log file sysedge log When events occur frequently it may be useful to disable event logging eHealth SystemEDGE User Guide 292 e Chapter 11 Configuring Process and Service Monitoring Table 40 Process Monitor Table Flags Page 2 of 4 Pag Desorption 0x00000010 Send continuous processStop traps for this entry each time the agent attempts to reinitialize proces
310. l Port Status Checking By default the SystemEDGE agent automatically determines the status of all serial devices on the host system as part of its support for the hrDeviceTable from the Host Resources MIB Some serial applications however encounter problems because they are unable to handle the opening and closing of serial devices which are necessary for determining status by any process other than themselves For example some tty and serial applications become confused when another application briefly opens and closes a serial port device To circumvent these problematic serial applications use the no_serial_status configuration option to configure the agent to check only the keyboard and mouse In this case the agent returns unknown 1 for the status of serial ports when it is queried by management systems To inhibit serial port status checking uncomment the following line in sysedge cf by removing the pound sign character from the following line no serial status Configuring Support for Disk Probing By default the SystemEDGE agent automatically determines size capacity description and other properties of disks and CD ROMs that may be installed on the underlying system The agent usually uses I O control functions for example UNIX eHealth SystemEDGE User Guide Configuring Support for Actions 137 ioctls to obtain this information However on some older UNIX systems for example HP UX probing of disk
311. le In this case the management station decides whether it needs to be able to set a value for that particular columnar instance If not the management station re issues the management protocol set operation but without setting a value for that particular columnar instance otherwise the management station aborts the row creation algorithm Interaction 2b Negotiating the Creation of the Conceptual Row The management station issues a management protocol set operation which sets the desired instance of the status column to createAndWait If the agent is unwilling to process a request of this sort the set operation fails with an error of wrongValue As a consequence such an agent must be prepared to accept a single management protocol set operation 1 e interaction 2a eHealth SystemEDGE User Guide 920 e Appendix D Textual Conventions for Row Status above containing all of the columns indicated by its column requirements Otherwise the conceptual row is created a noError response is returned and the status column is immediately set to either notInService or notReady depending on whether it has sufficient information to make the conceptual row available for use by the managed device If there is sufficient information available then the status column is set to notInService otherwise if there is insufficient information then the status column is set to notReady Regardless we proceed to interaction 3 Interaction 3 Ini
312. le in the etc directory for UNIX systems or the SystemRoot system32 directory for Windows systems A license key consists of four space separated 8 character sequences such as the following YFAbDHSgN cSzdjW92 nxXjOO0O5w tHYBXs9ON The following is a sample SystemEDGE agent license file A pound sign character in column 1 indicates that the entire line is a comment license file for SystemEDGE Agent Concord Communications Inc http license concord com file etc sysedge lic or S6SystemRoot system32 sysedge lic A valid license key has four parts of 8 characters per part parts are separated by space s with one license key per line ee sysedge jupiter sol2 5 9 807cbhlda007cbhlda 4 2 PL 1 e13311dqd3 0F2a7cb1 abCSlzZde fF8C923a Licensing Methods 107 NOTE You must license both permanent and evaluation copies of the agent If you are evaluating the SystemEDGE agent CA can provide you with a temporary license that allows the agent to operate during the evaluation period Licensing Methods Table 10 lists the methods for licensing the SystemEDGE agent and identifies which are useful for local and remote licensing which provide automatic licensing which provide proxy support and which you can use even if the system that you are licensing does not have internet access Table 10 Licensing Methods Licensing Method Local Remote Automatic Proxy Support Possible without Internet Access for the Targe
313. led a bucket holds the value of the specified MIB object gathered during one sampling interval As each sampling interval occurs the agent adds a new row to the History table with the same empireHistoryIndex value as other rows for this data collection function This new row corresponds to the single row in the History Control table and has an empireHistorySampleIndex value that is one greater than the SampleIndex of the previous sample History Sampling Examples Table 24 shows sample entries in the History Control table Table 24 Sample History Control Table Entries Int Type Bckts Bckts Last Create Status Req Grant Call Time 1 Minute loadAverage1 Min 0 active 1 ran Load 30 Memory memInUse 0 Od Od 0 0 0 active 1 In Use 6 30 30 Swap swapCapacity 0 Od Od 2 00 00 active 1 Capacity 6 30 00 The History Control table uses the SNMPv2 Structure of Management Information SMI Row Status Textual Convention for adding and deleting rows For more information about the conventions for row status refer to Appendix E eHealth SystemEDGE User Guide History Table 207 In this example Table 24 the rows are defined as follows e Control row 1 causes the agent to poll the 1 minute load average every minute and to store the most recent 5 samples 5 minutes e Control row 2 causes the agent to poll the memoryInUse MIB variable every 30 seconds and to store the most recent 10 samples 5 minutes e Control row
314. lesystem devCapacity 19 0x0 120 absolute gt 95 Monitor Filesystem eHealth SystemEDGE User Guide 272 e Chapter 10 Configuring Threshold Monitoring The values in this example are defined as follows The variable identifier devCapacity indicates the particular MIB object instance to monitor in this case the object instance is devlableEntry devCapacity from the Systems Management MIB devTable The object instance is not specified because it is determined automatically based on the name of the file system 19 indicates that this entry is row 19 in the Monitor table 120 indicates that the agent should sample every 120 seconds absolute is the appropriate sample type because the agent is sampling an integer not counter value that represents how full the file system is 95 specifies the value to use in the comparison If the file system becomes greater than gt 95 full the agent sends a trap message to all configured managers indicates that no action is specified Monitoring Space on the usr File System The following example configures the SystemEDGE agent to monitor the usr file system and to send a trap message when it becomes more than 95 full monitor filesystem usr devCapacity 20 0x00100500 120 absolute gt 95 Monitor usr Filesystem eHealth SystemEDGE User Guide The values in this example are defined as follows The variable identifier devCapacity indicates the particular MIB o
315. line utilities that are provided with it Man page for the SystemEDGE agent sysedge cf 5 Man page that describes how to specify configuration settings for the agent by placing them in the sysedge cf configuration file sysedge mon 5 Man page that describes how to specify entries for the agent s self monitoring tables by placing them in the sysedge mon configuration file sysvariable Man page that describes how to use the sysvariable utility to query systems and exercise the agent walktree 1 Man page that describes how to use the walktree utility to retrieve specific MIB variables xtrapmon Man page that describes how to use the xtrapmon utility to receive and log SNMP trap messages eHealth SystemEDGE User Guide 92 e Chapter 2 Installing the SystemEDGE Agent NOTE You can use the nroff command to view Man pages from the command line if your Man path is not set correctly To do so enter the following nroff man sysedge 1 more Directories and Files for Windows Systems Table 8 describes the directories and files that the SystemEDGE agent installation creates for Windows systems only Table 8 SystemEDGE Directories and Files for Windows Systems Page 1 of 3 Directory Fie Description setup exe Command line version of the installation program for SystemEDGE Note You do not need to use this file if you installed SystemEDGE through InstallShield sysedge cpl SystemEDGE Control Panel You can use th
316. lity Codes Creating a Log File for Daemon Messages 491 Table 85 describes the syslog priority codes Table 85 syslog Priority Codes The typical syslog configuration logs messages to the text file var adm messages on Sun SPARC systems and to usr adm syslog on HP UX Release 10 x and 11 x systems If the message has a priority of LOG_ERR or higher syslog also displays the message to the console Creating a Log File for Daemon Messages Because the typical log file contains messages from many facilities in addition to daemon processes like the SystemEDGE agent you may want to configure all messages from daemon processes to be logged to a separate daemon log file If your etc syslog conf file does not already contain an entry for logging daemon processes separately you can add an entry to cause syslog to log those messages to a separate daemon log file eHealth SystemEDGE User Guide 492 e Appendix B_ Using the syslog Facility Creating a Daemon Log File for Sun SPARC Systems To create a separate file for logging daemon messages for a Sun SPARC system edit the etc syslog conf file by entering following daemon var log daemon log Creating a Daemon Log File for HP UX Systems eHealth SystemEDGE User Guide To create a separate file for logging daemon messages for HP UX versions 10 x and 11 x systems edit the etc syslog conf file by entering following daemon info usr adm daemon log These changes take e
317. llation Procedure 118 Belore Yow BEN ns ta5828ono0 sem tnetesesin pare sneaeoesos 118 Sample sysedpe ci Miles ati atecansnus sda agate teueeeeeeens 119 Configuring System Information 0 2 eee 128 Configuring Access Communities eee eee eeee 128 Specifying the Access List i450 300seasseeosae es ia sees 129 Dera Setting Saee eeeeecatret eet hedeiaeestseeenceues 130 Configuring Trap Communities 202 eee eee 130 Specifying a Trap Source cc cece cece eee eee 131 Configuring Authentication Failure Traps 132 Configuring Support for Who Table Information 132 Configuring Support for User and Group Information 133 Configuring Support for Remote Shell Capability 133 Configuring Alternative Syslog Facilities UNIX Only 134 Configuring Alternative Syslog Facilities Windows Only 134 eHealth SystemEDGE User Guide 6 e Table of Contents Chapter 5 Configuring Support for Agent Debugging 135 Configuring Support for Floppy Status Checking 135 Configuring Support for Serial Port Status Checking 136 Configuring Support for Disk Probing 136 Configuring Support for Actions 0 e eee eee 137 Disabling Support for Remote File System Checking UNDP OND x ad ose giew oe ote a cua Gao eee Gta dee ones 138 Configuring Support for Threshold Monitoring
318. llection End of the entry is marked by a closed bracket eHealth SystemEDGE User Guide 910 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Sample NT Event Monitor Entries in sysedge mon This section includes an example for adding an entry to the NT Event Monitor table through the sysedge mon file Monitoring for Application Errors eHealth SystemEDGE User Guide The following entry instructs the SystemEDGE agent to monitor the Application NT Event Log for events of type Error If a match is found the agent sends an SNMP trap message nteventmon 5 Application ERROR Application Error xu xu active woe 0x0 Adding History Control Table Entries to the sysedge mon File 511 Adding History Control Table Entries to the sysedge mon File History Control Table entries begin with the keyword history They are delineated by open and closed brackets and they include six fields Table 91 describes the field for NT Event Monitor table entries in the sysedge mon file Table 91 Columns of the History Control Table Page 1 of 2 Fein Cinai aa Beginning of the entry is marked by an open bracket empireHistoryControlIndex Integer 1 to MAXINT that uniquely identifies the entry in the table The index is particularly important because SNMP does not directly support creation and deletion of MIB objects instead it creates and deletes them as side effects of SNMP Set opera
319. lore IEXPLORE 458 0x200508 60 absolute gt 50000 TIE Roo Olze T NT service monitoring examples watch ntservice Simple TCP IP Services 10 0x8 60 Monitor TCP services watch ntservice World Wide Web Publishing Service 500 0x8 30 IIS WWW Service 74 watch ntservice Exchange Store 501 0x8 30 Exchange Info Store watch ntservice sglagent 502 0x8 30 SQL Server Agent Service eHealth SystemEDGE User Guide 126 ee H H You can add Chapter 4 Configuring the SystemEDGE Agent process group monitoring entries to have the agent automatically monitor a group of running processes Usage watch procgroup Examples watch procgr Watch Exchange You can add monitor MIB Usage monitor oid Examples monitor oid monitor oid monitor oid monitor oid average monitor oid average monitor oid average monitor oid utilization monitor oid utilization monitor oid Length gt 3 regexp index flags interval descr action oup dsamain emsmta store mad DSAMAIN EMSMTA STORE MAD 01 0x0 60 self monitoring entries to have the agent automatically variables This creates an entry in the Empire Monitor Table objid name index flags interval stype oper value descr action numInterrupts 0 14 0x200508 60 delta gt 10000 Interrupt Rate numPageFaults 0 15 0x200508 60 delta gt 1000 Page fault Rate hrSystemProcesses 0 19 0x200508 60 abso
320. ltiple of 30 seconds pgmonProcRegExpr Regular expression to apply when the agent is attempting to match processes by name pgmonFlags Integer flags value that indicates additional behavioral semantics this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field refer to Chapter 12 Configuring Process Group Monitoring eHealth SystemEDGE User Guide 904 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Table 88 Fields for Process Group Monitor Table Entries Page 2 of 2 pgmonAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the expression evaluates to True and a trap is sent If the string is empty no action will be performed for this entry pgmonRowStatus One of the following active notInService notReady createAndGo createAndWait Normally a row is either active or notInService These values are identical in meaning to the SNMPv2 SMI RowStatus textual convention For more information refer to Appendix E End of the entry is marked by a closed bracket eHealth SystemEDGE User Guide Sample Process Group Monitor Entry in sysedge mon 505 Sample Process Group Monitor Entry in sysedge mon This section includes an example for adding entries to the Process Group Monitor table through the
321. lute gt 120 Num Processes loadAveragelMin 0 11 0x200508 60 absolute gt 300 1 minute load loadAverage5Min 0 12 0x200508 300 absolute gt 200 5 minute load 15 minute load loadAveragel5Min 0 13 0x200508 900 absolute gt 200 swapCapacity 0 25 0x200508 60 absolute gt 90 goz Warning Swap memCapacity 0 26 0x200508 60 absolute gt 85 e i Warning Memory ntRunQLen O 27 0x200508 60 absolute gt 3 Warning Run Queue eHealth SystemEDGE User Guide EEH H H HEHHEHE E HEHE E EAE EHA HHA HHHH HH H H H Sample sysedge cf Fie 127 You can add file system monitoring entries to have the agent automatically monitor a file system based on the mount point This creates an entry in the Empire Monitor Table Usage monitor filesystem name attribute index flags interval stype oper value rdescr Taction Examples monitor filesystem C devCapacity 60 0x200508 60 absolute gt 90 C Drive is gt JO TI monitor filesystem D devCapacity 61 0x200508 300 absolute gt 95 D Drive io She TI monitor filesystem E devCapacity 62 0x200508 300 absolute gt 95 E Drive is gt goo TI monitor filesystem F devCapacity 63 0x200508 300 absolute gt 95 F Drive ie gt ooo TI monitor filesystem C devCapacity 64 0x200508 300 absolute gt 98 C gt 98 C sysedge bin email exe r mymailservername sysedge mydomain com mis mydomain com C gt 98 machin
322. ly those changes for a pattern match Pattern matches result in ntEventMonMatch events Format of Trap PDUs 221 ntEventMionNotReady Trap The following code shows the format of an ntEventMonNotReady trap which the SystemEDGE agent sends to indicate that the status of a Windows event log monitoring entry has become notReady 3 ntEventMonNotReadyEvent OBJECT IDENTIFIER traps 8 ntEventMonNotReadyTrap TRAP TYPE ENTERPRISE empire VARIABLES ntEventMonLog ntEventMonTypeFilter ntEventMonSrcFilter ntKventMonDescFilter ntEventMonDescr ntEventMoniIndex ntEventMonFlags DESCRIPTION This trap is sent when the status of an event log monitoring entry becomes notReady 3 An entry becomes notReady 3 if an error occurs during log file scanning if the regular expression is syntactically incorrect or if the log file does not exist An entry that is notReady 3 will undergo no further evaluation until its status becomes active 1 eHealth SystemEDGE User Guide 222 e Chapter 8 Private Enterprise Traps monitorClear Trap eHealth SystemEDGE User Guide The following code shows the format of a monitorClear trap which the SystemEDGE agent sends to indicate that a condition that previously existed no longer exists The SystemEDGE agent sends this trap when a Monitor table entry that has a set Clear Trap flag transitions from True to False monitorClearEvent OBJECT IDENTIFIER traps 9 monitorClearTr
323. m The main table in this group is the hrDeviceTable It lists all of the devices that the host contains The hrDevice group also includes a number of device specific tables that provide more detailed information for particular device types Host Resources Device Group 237 For example the group includes device specific tables for the following e Processors e Networks e Printers e Disk storage e Partitions e File systems If the hrDeviceTable shows that the host contains a Printer device for example you can retrieve more detailed information about the printer from the hrPrinterTable The following sections describe the hrDeviceTable and the device specific tables Device Table The hrDeviceTable lists the devices in the host system For each device in the hrDeviceTable the table lists the following e Device type e Description of the device Status for example running or down e Number of errors detected for the device Figure 24 shows an hrDeviceTable for a Sun SPARC IPX fe SNMP Table Display Table hrDeviceTable Path 1 3 6 1 2 1 25 3 2 1 Rows310 Columns36 hrDeviceType hrDeviceDescr hrDevicelD hrDeviceSt hrDeviceOther SUNW SPARCstation LX Sun Spare Workstation null running lt 2 hrDeviceProcessor TI THS390S10 null running lt 2 hrDeviceOther openprom PROM monitor configuration interface null running lt 2 gt hrDeviceSerialPort zs0 Zilog 8530 SCC Serial Communications Driver null running 2
324. m capacity Windows security and applications and systems NOTE The log files that are described in this section are not the same for all operating systems These examples are provided for reference you may need to alter them for your operating system Table 57 provides recommendations for files you can monitor for security Table 57 Monitoring Security fn nh Piers Taoa pay Monitor telnets in telnet Monitor rsh in rsh WARNING Illegal Instruction Daemon llegal nstruction Spam Relay Attempt Relaying denied Monitor DENY packets from a Linux firewall DENY eHealth SystemEDGE User Guide 352 e Chapter 13 Configuring Log File Monitoring Table 58 provides recommendations for regular expressions for which you can search in var adm messages to monitor for device failures Table 58 Monitoring Device Failures Critical Badtrap Error Error SCSI error SCSI E e rror Error SCSI error Error SCSI error Critical badsimms error Critical badsimms error Critical memory error M m emory E e rror Error disk error disk not responding Error disk error D d isk E e rror Warning disk fragmentation optimization changed error Error disk error corrupt label Error I O error 1 O E e rror Error disk read write errors Error for Command read write Error media error Media Error Info serialport error 75 0 1 2 silo overflow Warning ca
325. m configuration and hardware information Consequently the SystemEDGE agent will attempt to determine the system s configuration without the operating system s help perfDiskObjects X Num_Disks The SystemEDGE agent found a number of disk objects that is not equivalent to the number of disks it found through other mechanisms You can ignore this message realloc of mnt cache failed The SystemEDGE agent failed to reallocate space for its internal cache of mounted file systems This error usually occurs when the system is extremely low on memory The agent will continue to operate but may be unable to report file system statistics until more memory is available recvfrom failed The SystemEDGE agent encountered an error when reading an SNMP request from the underlying UDP transport reload_process table open proc failed The SystemEDGE agent failed to open the proc directory on a UNIX system consequently it cannot support the Process Monitor table eHealth SystemEDGE User Guide 464 e Appendix A Error Messages reload_process_table proc ioctl failed The SystemEDGE agent failed to perform an I O control operation ioctl on a particular process located in the proc directory The agent therefore cannot support process information for this particular process but will perform nominally for other processes root device ptr failed no openprom Upon startup on many UNIX systems the SystemEDGE agent attempts to di
326. m from which you will deploy the software If the deployment setup is invalid AdvantEDGE View stops the deployment AdvantEDGE View next checks each target system to ensure that it meets the deployment criteria For more information about the criteria refer to the eHealth AdvantEDGE View User Guide If the target system meets the installation criteria AdvantEDGE View copies the installation files based on the options you specified on the Agent Deployment form to the Deploying SystemEDGE from the Web 415 target systems If the system does not meet the installation criteria AdvantEDGE View displays an error on the Deployment Results Summary and moves on to the next target system Deploying SystemEDGE from the Web You can also deploy the SystemEDGE agent eHealth AIMs and other modules to your systems from a Web page within AdvantEDGE View or from the eHealth Software Downloads Web page 2 To access the AdvantEDGE View download page 1 Click the Agent Deployment icon AdvantEDGE View displays the SystemEDGE Deployment form Click the link in the Agent Downloads section of the form The Agent Downloads page appears displaying the products that are available for deployment Click the README link next to the package you want to install for installation instructions and the Package link to begin downloading the installation package Click Latest downloads from Concord to display the Software Downloads
327. m32 directory unable to process acl for community X This message indicates that the SystemEDGE agent was unable to parse an access control list specification as part of a community declaration in the sysedge cf configuration file The agent will ignore the offending access control list but will continue to support the corresponding community string declaration eHealth SystemEDGE User Guide 470 e Appendix A Error Messages unknown HP CPU type This message indicates that the underlying HP UX system contains a processor type that is not known to the SystemEDGE agent Report this message and the underlying processor type to Technical Support by sending e mail to support concord ca com unknown NT event log name This message indicates that an invalid Windows event log name was specified either through SNMP or through the nteventmon command line tool Valid Windows event log names are application security or system The agent will not create the NT Event Monitor table entry unknown NT event type This message indicates that an invalid Windows event type was specified either through SNMP or through the command line tool nteventmon Valid Windows event types are error warning information success fail or all The NT event monitor entry will not be created unknown service start type This message indicates that the SystemEDGE agent discovered a Windows service start type that it did not understand Report this message to
328. mEDGE agent with AdvantEDGE View and eHealth For more information refer to the eHealth AdvantEDGE View User Guide and the eHealth Administration Guide Automate management tasks through scheduling If you are using SystemEDGE with eHealth refer to the eHealth Administration Guide for more information eHealth SystemEDGE User Guide 44 e Chapter 1 Introduction eHealth SystemEDGE User Guide Limit SNMP access to the agent through access control lists and binding to private interfaces Use read write communities for SNMP Sets and read only communities for querying and polling For more information about specifying community strings refer to Configuring Access Communities on page 128 Use either port 161 the SNMP industry standard port or 1691 which is reserved with the Internet Assigned Numbers Authority IANA for use with the SystemEDGE agent For more information about configuring ports refer to Configuring the SNMP Bind Address on page 143 Create groups in your management software based on the following Operating systems Database systems Clients File servers E mail servers Web servers Physical location For more information about creating groups refer to the eHealth Administration Guide Define policies across groups of systems instead of on an individual system basis Use management software such as AdvantEDGE View to push rules to groups of systems
329. management station should simply select a new pseudo random number and retry the operation A MIB designer should choose between the two latter algorithms based on the size of the table and therefore the efficiency of each algorithm For tables in which a large number of entries are expected it is recommended that a MIB object be defined that returns an acceptable index for creation For tables with small numbers of entries it is recommended that the latter pseudo random index mechanism be used Interaction 2 Creating the Conceptual Row Once an unused instance identifier has been selected the management station determines if it wishes to create and activate the conceptual row in one transaction or in a negotiated set of interactions Interaction 2a Creating and Activating the Conceptual Row The management station must first determine the column requirements i e it must determine those columns for which it must or must not provide values Depending on the complexity of the table and the management station s knowledge of the agent s capabilities this determination can be made locally by eHealth SystemEDGE User Guide 918 e Appendix D Textual Conventions for Row Status eHealth SystemEDGE User Guide the management station Alternately the management station issues a Management protocol get operation to examine all columns in the conceptual row that it wishes to create In response for each column there are three possibl
330. mands from a management system such as AdvantEDGE View to modify the table For more information refer to the next section Dynamic Configuration During Operation At start up initialization Specify the entries for the NT Event Monitor table in the SystemEDGE agent configuration file sysedge cf For more information refer to Initial Configuration During Start Up on page 369 Dynamic Configuration During Operation The agent uses the SNMPv2 SMI Row Status textual convention for creating deleting and modifying rows in the table For more information about this convention refer to Appendix E You can use your NMS platform to issue SNMP Set request messages to the SystemEDGE agent in order to modify the entries in the NT Event Monitor Table NT Event Monitor table entries are saved to the sysedge mon configuration file so that any changes made during the operation of the agent are preserved across agent and system restarts NOTE Configuration file directives in the sysedge cf file take precedence over entries in sysedge mon For example if a NT Event Monitor table entry is contained in sysedge mon at index 10 and a configuration file directive is added to sysedge cf for index 10 of the NT Event Monitor table the entry that is defined in sysedge cf overwrites the entry from sysedge mon Initial Configuration During Start Up On start up the SystemEDGE agent reads the sysedge cf configuration file and uses the
331. me directory as the current file This error message indicates that the rename operation failed The SystemEDGE agent will continue to function normally but the contents of the old monitor table will not be recoverable failed to allocate history entry The SystemEDGE agent failed to allocate memory for a history table entry It will therefore not create a history table entry and the configuration file statement will be ignored The SystemEDGE agent will however continue to parse the remainder of the configuration file failed to send COLDSTART trap The SystemEDGE agent failed to send a MIB II defined Cold Start trap message to its SNMP management systems This error usually results from underlying operating system problems The SystemEDGE agent will continue to operate normally and will attempt to continue to send SNMP trap messages as necessary fork failed for extension command The SystemEDGE agent failed to fork itself in order to execute the extension command Fork failures occur if the system has insufficient resources to create new processes This error indicates that no extension command was executed fork failed for monitor action The SystemEDGE agent failed to fork itself in order to execute the monitor action Fork failures occur if the system has insufficient resources to create new processes This error indicates that no monitor action was executed but the monitor table row is still active and will continue to attem
332. mitted by the agent to standard output file descriptor 1 Starting the Agent Automatically at System Boot You can configure your system to automatically start the SystemEDGE agent whenever the system is booted eHealth SystemEDGE User Guide 152 e Chapter 5 Starting the SystemEDGE Agent NOTE If you answered yes to the installation script prompt Disable native SNMP Agent if applicable the installation script configured your system to start the SystemEDGE agent automatically whenever the system is booted If you did not configure your system to start the SystemEDGE agent at system boot during the installation process you can do so by following the instructions in this section This section includes instructions for the following operating systems e Solaris e Windows page 153 e HP UX page 153 Linux page 154 AIX page 154 Digital UNIX or Tru64 page 155 Starting the Agent Automatically for Solaris Systems eHealth SystemEDGE User Guide For Solaris 2 x systems the SystemEDGE agent s config subdirectory contains a script named S99sysedge The installation process places this script in etc rc2 d to start the agent automatically at boot time If you installed the agent in a directory other than the default opt EMPsysedge you must edit the S99sysedge script to reflect those changes In addition you must edit the script to include the correct directory for the agent s configuration
333. mmunity is identified by a string of octets called the community name which appears in the header portion of every SNMP message The agent checks the community name in the SNMP message header to determine if the message is authentic If the community name matches one that is accepted by the agent the message is considered to be authentic and the agent processes the message If it does not match the agent records an IP spoofing occurs when a system impersonates a trusted system to gain access to another system Simple Network Management Protocol 49 authentication failure and drops the message The community name also serves to determine what level of access read only or read write is available when the agent is using that community name NOTE Although the community name is similar to a password providing access to read and even change the values of an agent s MIB objects the community name is not encrypted when it appears in an SNMP message header it appears in clear text Although it is possible to attach IP based access control lists to individual communities IP spoofing can circumvent the access control lists Consequently you should consider SNMP Version 1 SNMPv1 communities insecure and take configuration steps to limit potential security violations In addition you should improve the overall security of the distributed system through router and system configuration For more information refer to Chapter
334. modifying Process Monitor table entries through the processmon command or by editing sysedge mon must know the exact MIB table index to use for row creation pmonDescr Quoted string that is 0 through 128 characters in length and that normally contains a description of the process and attribute that the agent is monitoring as well as a severity level for this event pmontInterval Integer value 30 to MAXINT that indicates how often in seconds the agent should perform this monitoring For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds pmonSampleType Either absoluteValue 1 or deltaValue 2 this value indicates whether the agent should sample the attribute s absolute value or take the difference between successive samples For example use deltaValue to monitor counter attributes because it provides the rate of change Use absoluteValue to monitor gauges because it provides the object s exact value eHealth SystemEDGE User Guide 900 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Table 87 Fields for Process Monitor Table Entries Page 2 of 3 pmonAttribute Process attribute that is being monitored For a complete list of supported attributes refer to Chapter 11 Configuring Process and Service Monitoring For example to monitor a process to ensure that it is alive specify the attribute procAlive To track the number of
335. mport the MIB file your management system software will not be able to access the new extension MIB objects Recommendations for Using Extensions When you create SystemEDGE extensions follow these guidelines Do not edit empire asn1 Use a separate MIB specification Use SystemEDGE debugging log file monitoring to find output plug in and extension problems Use 128 characters or less for extension entries to meet the Windows limitation on command line length Remember that the length includes paths commands and arguments Do not use batch files Instead use Windows scripting VBScript Perl C Shell and so on Watch the fork exec time for new extensions Extensions are synchronous and can block other actions eHealth SystemEDGE User Guide TESEN Adding Windows Registry and Performance MIB Objects agent The SystemEDGE agent provides a powerful mechanism for extending the Systems Management MIB to include information from the Windows registry and performance counters This information includes configuration data which is normally viewed with regedit and performance data which is normally viewed with perfmon Using this feature you can customize the SystemEDGE agent to return additional configuration and performance data for your systems and applications For example you can use the SystemEDGE agent to make many application registry entries that specify the configuration of the application available
336. mportance While UNIX based agents can change this log level through the command line d option the SystemEDGE agent on Windows cannot because no command line options are available to it Consequently to use the configuration file option to instruct the SystemEDGE agent on both UNIX and Windows systems to log messages of priority LOG_DEBUG or lower uncomment the following line by removing the pound sign character sysedge_debug For more information on the syslog facility refer to Appendix B NOTE On Windows systems all syslog output is logged to the file SystemRoot system32 sysedge log For more information refer to Configuring Alternative Syslog Facilities Windows Only on page 134 Configuring Support for Floppy Status Checking By default the SystemEDGE agent automatically determines the status of all floppy devices on the system as part of its support for the hrDeviceTable from the Host Resources MIB On some UNIX systems however when you check the status with the stat command of a floppy device that contains no media the console and some system log files display warning eHealth SystemEDGE User Guide 136 e Chapter 4 Configuring the SystemEDGE Agent messages To circumvent these warning messages configure the agent to not check status of floppy drives To do so uncomment the following line in sysedge cf by removing the pound sign character no_stat_floppy Configuring Support for Seria
337. n refer to Chapter 4 Configuring the SystemEDGE SP Agent c Save and close the file You can also use the Control Panel to do the following e Start and stop the agent e View community strings and trap destinations in the Read Community Read Write Community and Trap Destinations fields e View and edit the configuration and license files by clicking sysedge cf sysedge mon or sysedge lic e View the SystemEDGE log file by clicking sysedge log e Run the diagsysedge utility by clicking diagsysedge e View this guide or the eHealth SystemEDGE Release Notes by clicking Manual or Release Notes After the installation you can access the SystemEDGE Control Panel by selecting Start Settings Control Panel and double clicking eHealth SystemEDGE When you are finished modifying the SystemEDGE configuration click Close NOTE If you did not specify a read write community string an informational dialog box informs you that you cannot automatically license the agent without specifying a read write community string Click OK and then return to the SystemEDGE Control Panel to specify a community string unless you do not want to license the agent automatically eHealth SystemEDGE User Guide 68 eoe Chapter 2 Installing the SystemEDGE Agent 17 The following dialog box appears You must click Yes to continue and complete the installation If you click No the installation will be aborted The Concord Sy
338. n 5 man page 91 syslog facility configuring alternative UNIX 134 eHealth SystemEDGE User Guide Windows 134 facility codes 490 logging agent operation messages 155 daemon messages 491 messages 489 overview 489 priority codes 491 SystemEDGE agent configuration files 86 overview 117 configuring support for debugging 135 current information 26 default settings 130 error messages 439 guidelines 43 installation directories 90 licensing overview 105 logging messages 155 overview 27 removing 98 self monitoring features 31 specifying actions 35 starting 149 supporting custom MIB objects 34 traps 215 troubleshooting 423 uninstalling 98 using with eHealth 40 Fault Manager 42 Windows event monitoring 33 extensions 34 Systems Management MIB adding support for Windows registry and performance counters 403 boot configuration parameters 169 configuring support Group information 133 history collection 142 Log Monitor table 141 NT Event Monitor table 141 Process Group Monitor table 141 Process Monitor table 139 Remote Shell group 133 User information 133 Who Table 132 CPU Statistics group 211 Disk Statistics group 208 extending monitoring capability 391 Extension group overview 391 using 212 History table 205 Host System group 166 I O buffer cache 184 interprocess communications 180 kernel configuration parameters 168 performance 178 Log Monitor table 204 message buffers 182 Monitor table 202 mounte
339. n action is configured the agent also invokes the action If the process restarts the agent automatically detects the new PID reinitializes the corresponding entry and sends a processStart SNMP trap eHealth SystemEDGE User Guide 304 e Chapter 11 Configuring Process and Service Monitoring When SystemEDGE is monitoring Windows services directly as enabled through the Process Monitor table flag 0x08000 the watch process procAlive configuration file directive automatically creates the following boolean expression for the Process Monitor table entry ntServiceStateZl When the service s status as determined by the NT Service table becomes notRunning its status does not equal 1 this expression evaluates to True and the SystemEDGE agent sends a processStop SNMP trap If an action is configured the agent also invokes it If the service restarts the agent automatically detects that the service has restarted and then reinitializes the corresponding Process Monitor Table entry and sends an processStart SNMP trap Using the watch process Directive to Monitor Process Attributes You can use the watch process directive to configure the SystemEDGE agent to monitor any attribute of a process other than its liveness procAlive Use the watch process directive as follows watch process attribute procname index flags interval stype operator threshold description eHealth SystemEDGE User Guide action Configuring the Pr
340. n active file you will need to stop the SystemEDGE agent before editing the file For more information on the format of this file refer to Appendix C For example to delete row 14 1 Stop the SystemEDGE agent 2 Open sysedge mon for editing delete the entry for procgroupmon row 14 and save the file 3 Open sysedge cf for editing delete the entry for procgroupmon row 14 if it exists and save the file 4 Restart the SystemEDGE agent Configuring Log File Monitoring This chapter explains how to use the SystemEDGE agent to monitor log files for regular expressions Monitoring Log Files The SystemEDGE agent can monitor ASCI based text files continuously for the appearance of user specified regular expressions Whenever a match for the regular expression is written to the log file the agent is monitoring the agent notifies the management system with a trap message The flexible Log Monitor table of the Systems Management MIB enables you to configure the agent dynamically to monitor a log file for the regular expressions that you specify Each entry in the table represents the monitoring of a single log file for a particular regular expression This log file monitoring provides a very flexible solution for monitoring applications by monitoring the messages that the applications log This feature is also useful for security management for example you can configure the agent to monitor system log files for su messa
341. ndicates that the agent should check the TCPSVCS process every 30 seconds e No action is specified so the agent will not invoke a command when it sends a trap eHealth SystemEDGE User Guide 308 e Chapter 11 Configuring Process and Service Monitoring NOTE This example illustrates how to monitor the underlying process that provides the Windows Simple TCP IP Services service The following example illustrates how to monitor the Windows service itself rather than its underlying process Monitoring the Simple TCP IP Services Service Both of the following examples configure the SystemEDGE agent to monitor the TCPSVCS service itself rather than the underlying process watch process procAlive Simple TCP IP Services 15 0x08000 30 Monitor NT TCP IP Services OYr watch ntservice Simple TCP IP Services 15 0x0 30 Monitor NT TCP IP Services The values in this example are defined as follows e 15 indicates that this entry will occupy row 15 pmonIndex 15 in the Process Monitor table The flags field value of 0x08000 indicates that the agent should monitor the Windows service rather than the underlying process e 30 indicates that the agent should check the Simple TCP IP Services service every 30 seconds e No action is specified so the agent will not invoke a command when it sends a trap Monitoring ypbind To Make Sure It Is Running The following example configures the SystemEDGE agent to monito
342. ndows Systems 89 SystemEDGE Agent Directories and Files 90 Directories and Files for UNIX Systems 45 90 Directories and Files for Windows Systems 92 Directories and Files for All Platforms 94 eHealth SystemEDGE User Guide Chapter 3 Chapter 4 Table of Contents e 5 Uninstalling the SystemEDGE Agent 0 4 98 Uninstalling SystemEDGE for Solaris Systems 98 Uninstalling SystemEDGE for Windows Systems 98 Uninstalling SystemEDGE for HP UX Systems 101 Uninstalling SystemEDGE for Linux Systems 102 Uninstalling SystemEDGE for AIX Systems 102 Uninstalling SystemEDGE for Digital UNIX and Tru64 Systems 05 3c405 seddwaswadeicowraowinw sss 103 Licensing the SystemEDGE Agent 105 Licensing the Agent se oan nd ooh oe See wend oe boise eeeaes 105 GICENSe REVS TTET T E ree anesei os Bosna 106 Licensing Methods 0 cee eee cece cece teens 107 Obtaining a License Key aso tcccincadwansdscieseraawiwa ded 108 Running the licenseme Utility 006 109 Sending an E mail Request for a License Key 110 Using the Web Based Licensing Form 111 Using the licenseutil p Utility 006 112 Configuring the SystemEDGE Agent 117 Interactions Between sysedge cf and sysedge mon 118 Configuring the Agent During the Insta
343. nds cd usr lpp EMPsysedge Install The installation script displays the following message Concord SystemEDGE Agent post installation starting eHealth SystemEDGE User Guide 84 e Chapter 2 Installing the SystemEDGE Agent This script enables you to configure the SystemEDGE agent You can change the configuration information after the installation if desired for more information refer to Chapter 4 Configuring the SystemEDGE Agent The installation script also enables automatic licensing of the agent For information about additional ways to license the agent refer to Chapter 3 Licensing the SystemEDGE c gt Agent NOTE For a detailed example of the installation script refer to Installing SystemEDGE on HP UX Systems on page 75 For each prompt the default value is shown in brackets You can press Return to accept the default or you can enter another value and then press Return Installing SystemEDGE on Digital UNIX and Tru64 Systems This section describes how to install the SystemEDGE agent on Digital UNIX and Tru64 systems See the Preface for a list of supported systems and versions System Requirements Before you begin installing the agent verify that your system meets the following requirements e CD ROM drive At least 8 MB RAM At least 4 MB free disk space Installing the Software Digital UNIX and Tru64 defines The SystemEDGE agent software distribution for Digital
344. nfo The SystemEDGE agent was unable to get a disk statistics structure out of the UNIX kernel Consequently disk statistics may not be supported for some or all disks failed to get domain name The SystemEDGE agent was unable to determine the system s DNS domain name This error usually occurs when the underlying system s DNS domain name is not configured This error has little effect on the SystemEDGE agent s overall operation failed to get service handle The SystemEDGE agent was unable to obtain a Windows service handle On Windows service information is obtained through an operating system specific resource termed a handle This message indicates that there was a problem obtaining a particular service s handle The SystemEDGE agent will continue operation but may not be able to provide all information about a particular Windows service failed to open dev netman On HP UX systems the SystemEDGE agent was unable to open the device dev netman which allows the agent to support MIB II Verify that the dev netman file exists and that the SystemEDGE agent has permission to read it Running the SystemEDGE agent as a user other than the root user can cause this problem failed to open system eHealth SystemEDGE User Guide On HP UX 9 x systems the SystemEDGE agent failed to open the system directory for inspection of locally installed software packages and patches Check that the system directory exists and that the
345. nformation refer to Configuring Support for User and Group Information on page 133 Figure 6 shows a sample Group table e SNMP Table Display Tablet groupTable Path 1 5 6 1 4 1 546 1 1 4 1 Rows 10 Columns 4 Instance group Index grouphame groupPasswd groupbIl 1 1 wheel i 2 2 nagrau if boos A a daemon 1 4 4 kmem 2 5 5 bin 5 E E tty 4 T T operator if S 0 E NEWS E J J LULUCF E 10 10 audit J Ea est Fae Figure 6 Systems Management MIB Group Table eHealth SystemEDGE User Guide 174 e Chapter 7 Systems Management MIB Process Information eHealth SystemEDGE User Guide Use the Process table to determine what processes are currently running on the system Each row in the table represents a process and contains columns that represent the following Process ID Name State Flags Owner user ID UID Owner group ID GID Scheduling priority Amount of memory and CPU time that the process is using You can also control processes through the Process table For example you can increase or decrease a process s scheduling priority by setting the desired priority value in the process s nice column You can also send a signal to a process by setting the kill column to the desired signal value For example from a remote network management station console you can terminate an unauthorized process by setting the value of its processkKill column to 9 the number that re
346. ng Log Monitoring Entries 0006 349 Removing Entries from the sysedge cf File 349 Removing Entries with the edgemon Utility 350 Removing Entries Manually 0 2 0 0 2 ee eee 350 Recommendations for Log File Monitoring 351 Monitoring Log File Size 0 ee eee eee eee 354 Rotating Log Files soc oc0208 sek easeuacecedees rtirata 355 eHealth SystemEDGE User Guide Chapter 14 Chapter 15 Table of Contents 13 Configuring Windows Event Monitoring 39 7 Monitoring Windows Events 0 e cee ee cece eeees 357 Monitoring Windows Event Logs e eee eee 358 Checking Log Pile Status s 2 saceneccadecavetooseseces 358 Search Cites i ctnsan peeeneenaeeenea pe eeeaeseueod 359 NT Event Monitor Table 5 220 224 0928 sdb3denteenndonsseees 360 Columns of the NT Event Monitor Table 360 Optimizing Row Creation 0 ee ee eee eee 363 NT Event Monitor Table Flags 0 0 cece eee eee 363 NT Event Monitor Table Actions 0 20 20 2 eee 366 Viewing the NT Event Monitor Table with MOVAnI EDGE VIEW cox canara onsias aeldaeawninn as akadt oes barks 368 Configuring the NT Event Monitor Table 368 Dynamic Configuration During Operation 369 Initial Configuration During Start Up 369 watch ntevent Directive Examples 00000 371 Using the edgewatch Utility t
347. ng eHealth SystemEDGE 29 Internet Control Message Protocol ICMP User Datagram Protocol UDP Simple Network Management Protocol SNMP For more information about MIB II refer to RFC 1213 Host Resources MIB The Host Resources MIB is defined by the Internet Engineering Task Force IETF to provide management information for generic host systems The MIB includes information that is especially useful for asset management such as the following e Storage areas such as file systems and disk partitions e Running and installed software e System devices such as keyboards disks and network cards For more information about how the SystemEDGE agent uses the Host Resources MIB refer to Chapter 9 Host Resources MIB Systems Management MIB The Systems Management MIB is a private enterprise MIB that includes objects for monitoring the health and performance of the underlying system and its applications This MIB defines management information for the following e Kernel and system parameters e Boot configuration e Network streams and I O buffer statistics e Network file system NFS and Remote Procedure Call RPC statistics e Kernel performance statistics such as the number of context switches and page faults e File systems e Mounted devices e Users eHealth SystemEDGE User Guide 30 e Chapter 1 Introduction e Processes e Interprocess communications e System resources Table 2 describe
348. ng size of netscape process 502 monitoring TCPSVCS process 307 monitoring ypbind 308 flags description 291 overview 289 overview 283 process attributes 287 processClear trap 294 removing entries 315 sample sysedge mon entries 501 sample table entry 282 Systems Management MIB 203 using edgewatch utility 310 process monitoring introduction 32 sample entry 282 sending signal to a process 176 Process table 174 processClear trap example 294 processes automatically restarting 436 processmon keyword 499 procGroupChangeTrap 229 procgroupmon keyword 503 eHealth SystemEDGE User Guide 540 e ndex R remote file system status checking 138 Remote Shell group configuring support 133 Systems Management MIB 177 removing entries History Control table 389 Log Monitor table 349 Monitor table 279 NT Event Monitor table 376 Process Group Monitor table 331 Process Monitor table 315 SystemEDGE AIX 102 Digital UNIX 103 HP UX 101 Linux 102 Solaris 98 Tru64 103 Windows 99 reserving rows in self monitoring tables 258 restarting processes 436 restartproc sh 90 restartsvc exe 93 97 retrieving stored data samples 390 row status active 513 createAndGo 514 createAndWait 514 destroy 514 notInService 513 notReady 513 RPC group 185 eHealth SystemEDGE User Guide S S990sysedge script 95 S99sysedge script 95 searching application log specific events 372 Web server messages 371 event logs criteria 359 logs pop connection att
349. nly on systems that possess a valid license key This chapter provides an overview of the licensing options and explains how to obtain a license key NOTE You can license the agent during the installation procedure as well as during agent deployment if you are deploying the agent from a Windows system through AdvantEDGE View For more information about deploying and licensing the agent refer to Chapter 18 Deploying the SystemEDGE Agent This chapter describes alternative methods of licensing Licensing the Agent The SystemEDGE agent displays a message that it did not find a valid license when it starts unless you licensed the agent during the installation process Upon startup the unlicensed agent provides you with a public key that you must send to CA CA uses that public key to generate a valid license key for your system 105 106 e Chapter 3 Licensing the SystemEDGE Agent License Keys eHealth SystemEDGE User Guide An unlicensed SystemEDGE agent starts in restricted mode In this mode the agent can respond to a limited group of SNMP variables to support remote licensing For example you can query the agent for its version and licensing information If you configured a read write community string for the agent you can license it remotely using an SNMP Set command The SystemEDGE agent can run on a system that includes a license key that is valid for that system The license key must exist in the sysedge lic fi
350. non standard agent multiplexing solutions exist although they are not technically true agent multiplexing These solutions are based on the notion of monolithic agents whereby subagents are actually linked into the Master agent s executable binary or its address space while they are running This task can be accomplished without Master agent source code as long as the subagents adhere to the proprietary API There are several drawbacks to this approach e The agent developer may have to support multiple code bases because the proprietary APIs are often incompatible with those used within other agent source bases e Because the API is proprietary these subagents cannot communicate with other more open specifications such as DPI and SMUX The development and deployment of subagents usually involve licensing and royalty fees which are usually charged on a per CPU basis That means that the more subagents you deploy the more the user must pay in licensing and royalty fees In addition because this solution is proprietary every developer of the Master agent and subagents must purchase those APIs to make the pieces interoperate eHealth SystemEDGE User Guide 160 e Chapter 6 Using the SystemEDGE Agent with Other SNMP Agents Using the SystemEDGE Agent with the Solstice Enterprise Agent When you run the SystemEDGE agent on UDP port 1691 you can use it as a subagent under the Solstice Enterprise Agent SEA The SystemEDGE age
351. nprom device On Sun systems the SystemEDGE agent obtains some configuration information from the openprom facility This error message indicates that the agent was unable to open that file consequently some configuration information may not be supported failed to parse config file The SystemEDGE agent was unable to parse the configuration file Verify that the configuration file exists is in either the default location or the location that you specified on the command line and is readable The SystemEDGE agent will not operate if it cannot find a valid configuration file failed to push ARP for mib2 On Solaris 2 x the SystemEDGE agent needs access to the dev ip file and the arp Streams module in order to properly support MIB II Verify that the dev ip file exists and that it is readable by the SystemEDGE agent This problem can occur if you are running the SystemEDGE agent as a user other than the root user eHealth SystemEDGE User Guide 452 e Appendix A Error Messages failed failed failed failed failed eHealth SystemEDGE User Guide to push TCP for mib2 On Solaris 2 x systems the SystemEDGE agent needs access to the dev ip file and the tcp Streams module in order to properly support MIB II Verify that the dev ip file exists and that it is readable by the SystemEDGE agent This problem can occur if you are running the SystemEDGE agent as a user other than the root user to push UDP for mib2 On
352. nsible agent Take either of the following coexistence approaches e Run the Microsoft and SystemEDGE agents together on the system running the SystemEDGE agent on port 1691 and the Microsoft agent on port 161 e Turn off or disable the Microsoft Master agent and run the SystemEDGE agent on port 161 Using the SystemEDGE Agent with the HP SNMP Agent eHealth SystemEDGE User Guide HP UX systems ship with an extensible agent and subagents that provide support for MIB II and the HP rather limited private enterprise MIB The Master subagent interface is based on a proprietary API that the SystemEDGE agent does not support Take either of the following coexistence approaches e Run the HP and SystemEDGE agents together on the system running the SystemEDGE agent on port UDP 1691 Turn off or disable the HP master or subagent and run the SystemEDGE agent on port UDP 161 Using the SystemEDGE Agent with the AIX SNMP Agent 163 Using the SystemEDGE Agent with the AIX SNMP Agent AIX Release 4 1 and later systems ship with a MIB II SNMP agent that also supports SMUX You can run the SystemEDGE agent in addition to or in place of the AIX agent Take either of the following coexistence approaches Run the SystemEDGE and AIX agents together To do so make sure that the SystemEDGE agent is invoked with the p 1691 option in the AIX TCP IP startup script etc rc tcpip e Run the SystemEDGE agent instead of the AIX a
353. nstalledentry 1 gt me hrStorageEntry 1 HoreInfo Pie aac transmission 10 Up interfaces 2 host 25 gt Figure 21 Host Resources MIB Host Resources System Group The Host Resources System hrSystem group provides you with information that pertains to the host system as a whole Figure 22 shows the organization of the hrSystem group eHealth SystemEDGE User Guide Host Resources System Group 235 hrSystemNumUsers 5 hrSystemProcesses 6 hrSystemMaxProcesses 7 Figure 22 Host Resources System Group o hrSystemDate 2 hbrSystemInitialLoadDevice 3 brSystem 1 hrSystemInitialLoadParameters 4 Table 29 describes the information that is available through the Host Resources System group Table 29 MIB Objects Host Resources System Group HrSystem Uptime Amount of time since the host was last initialized HrSystemDate Host s settings for the local date and time of day HrSystemInitialLoadDevice Device from which the host loads its initial operating system configuration HrSystemInitialLoadParameters Pathname and parameters applied when loading the initial operating system HrSystemNumUsers Number of user sessions for which the host is storing state information HrSystemProcesses Number of processes that are currently loaded or running on the system HrSystemMaxProcesses Maximum number of processes that can be run on this system
354. nt installation package installs the appropriate configuration file Table 14 describes the SEA configuration files Table 14 SystemEDGE Configuration Files for SEA FileName Description OOOO sysedge reg Registration file that specifies the MIB branches to query the SystemEDGE agent and the UDP port number to which to send SNMP queries sysedge rsrc Resource configuration file that specifies the SystemEDGE agent type and the location of its corresponding registration file by default etc snmp conf sysedge reg To configure the SystemEDGE agent to run as a subagent under the SEA 1 Install the SEA packages that correspond to your version of Solaris and the underlying hardware architecture 2 Copy the SystemEDGE agent SEA configuration file into the SEA configuration directory etc snmp by entering the following commands from the directory where you installed the SystemEDGE agent cp config sysedge reg etc snmp conf cp config sysedge rsrc etc snmp conf eHealth SystemEDGE User Guide Using the SystemEDGE Agent with the Microsoft Windows SNMP Agent 161 3 Restart the SystemEDGE agent so that it will use port UDP 1691 instead of the default UDP 161 The S99sysedge script attempts to determine whether to use the SystemEDGE agent in conjunction with the SEA It does so by checking for the existence of the etc snmp conf directory and the etc rc2 d K76snmpdx file If the script determines that it should use both
355. nt is restarted Removing Entries with the edgemon Utility To remove a threshold monitoring entry from the Monitor table use the edgemon utility to delete the entry The following example deletes row 14 from the Monitor table on host 143 45 0 12 Once deleted the row is removed from memory and from the sysedge mon file edgemon 143 45 0 12 private delete 14 eHealth SystemEDGE User Guide 280 e Chapter 10 Configuring Threshold Monitoring Removing Entries Manually eHealth SystemEDGE User Guide In some cases you may be unable to use the edgemon utility to delete Monitor table entries For example if you have configured the SystemEDGE agent to disallow SNMP Set operations the edgemon utility does not work In this case you need to remove the threshold monitoring entry from the Monitor table by editing the sysedge mon file Because this is an active file you need to stop the SystemEDGE agent before you edit the file For more information on the format of the sysedge mon file refer to Appendix C For example to delete row 14 do the following 1 Stop the SystemEDGE agent 2 Open sysedge mon for editing delete the entry for monentry row 14 and save the file 3 Open sysedge cf for editing delete the entry for monentry row 14 if it exists and save the file 4 Restart the SystemEDGE agent Configuring Process and Service Monitoring This chapter explains how to use the SystemEDGE agent to monitor processes
356. nt should match all event types Source of the event This is a text field that contain the name of the program or module that generated the event The agent uses regular expressions to match this field Description of the event This is a text field that describes the event The agent uses regular expressions to match this field eHealth SystemEDGE User Guide 360 e Chapter 14 Configuring Windows Event Monitoring The SystemEDGE agent generates an SNMP trap message when it finds a match based on all four criteria This matching is similar to a Boolean AND operation NT Event Monitor Table For each entry in the NT Event Monitor table the table provides information such as the following Event log that the agent is monitoring e Regular expression for which the log is being monitored e Number of times that a trap has been sent because a match was found e Time at which the last trap was sent Log entry that caused the last match Columns of the NT Event Monitor Table Table 63 describes the columns of the NT Event Monitor table For more information about the NT Event Monitor table refer to the Systems Management MIB empire asn1 in the doc subdirectory of the SystemEDGE agent distribution Table 63 Columns of the NT Event Monitor Table Page 1 of 3 GS ntEventMonIndex Read Only Row of the table in which this entry exists ntEventMonLog Read Write Integer that designates which event log to monitor The
357. ntrolSet Services SNMP Start ntregperf 5 Integer Registry HARDWARE DESCRIPTION System Component Information ntregperf 6 OctetString Registry HARDWARE DESCRIPTION System SystemBiosVersion ntregperf 7 Integer Performance Memory Available Bytes 1 ntregperf 8 Counter Performance TCP Segments Received sec 1 ntregperf 9 Counter Performance UDP Datagrams Received sec 1 ntregperf 10 Counter Performance UDP Datagrams Sent sec 1 ntregperf 11 Integer Performance System System Up Time 1 ntregperf 12 Gauge Performance Objects Processes 1 NT Event monitoring entries are defined below each line instructs the agent to monitor a given NT Event log for a given rule match including regular expressions see man ed 1 for more details on regular expression syntax Usage watch ntevent index flags Eventlog Type Source Match Description Match De scription Action Examples watch ntevent 1 0x8 System Error System Error INFO Watch ntevent 2 Uxo Security Fail P FE 1 watch ntevent 3 0x8 Security All EMP Security WARNING eHealth SystemEDGE User Guide 122 e Chapter 4 Configuring the SystemEDGE Agent watch ntevent 100 0x8 System All W3SVC Logon failure Web Logon Failure watch ntevent 101 0x8 System All MSFTPSVC Logon failure TETP Logon Failure watch ntevent 102 0x8 System All MSFTPSVC User timed
358. o Chapter 3 Licensing the SystemEDGE c gt Agent NOTE For each prompt the default value is shown in brackets You can press Return to accept the default or you can enter another value and then press Return 5 Disable the native SNMP agent if you want to disable it by entering yes at the following prompt Disable native SNMP agent if applicable no For more information about running multiple SNMP agents simultaneously refer to Chapter 6 Using the SystemEDGE Agent with Other SNMP Agents The script displays the following Disabling native SNMP agent snmpdm stopped 6 Configure SystemEDGE to use UDP port 1691 if you are running another SNMP agent on port 161 by pressing Return at the following prompt Change SystemEDGE port to 1691 default is 161 yes eHealth SystemEDGE User Guide 10 Installing SystemEDGE on HP UX Systems 77 NOTE You must perform this step if you did not disable the native SNMP agent in the previous step Press Return at the following prompt if you want to enter a description for your system Configure system description yes a Enter the system description for example Test System and then press Return at the following prompt Enter system description followed by newline Press Return at the following prompt if you want to enter a location for your system Configure system location yes a Enter the system location for example Test sys
359. o Monitor Windows Events 372 edgewatch Commands for NT Event Monitoring 373 Sample Uses of edgewatch for Monitoring Windows Events 375 Removing NT Event Monitoring Entries 376 Removing Entries from the sysedge cf File 377 Removing Entries with the edgemon Utility 377 Removing Entries Manually 200 00 377 Configuring History Collection 379 History Collectio sy 2 444 awa ne Dees E neare T sees 379 History Sampling essssennnnnennnnnrrnnnnernnn n 380 History Control Table and the Data Table 380 Columns of the History Control Table 381 Columns of the History Table 20008 382 Optimizing Row Creation 0 e eee eee eee 383 Viewing the History Control Table with AdvantEDGE View 384 Configuring the History Control Table 384 Initial Configuration During Start Up 385 Dynamic Configuration During Operation 386 Using the emphistory Utility 0 00 0 ee eee 387 emphistory Utility Examples 00 0 0 cece ee eee 389 eHealth SystemEDGE User Guide 14 e Table of Contents Chapter 16 Chapter 17 Adding Custom MIB Objects 391 Systems Management MIB Extension Group 391 Features of the Extension Group 0c cece eee ee aes 392 Configuring Extension Variables 02 eee 393 Using the extension Keywo
360. o match a configuration file monprocess regular expression to a corresponding process name Consequently it will ignore the monprocess statement in the configuration file not querying serial port status eHealth SystemEDGE User Guide The SystemEDGE agent will not query the status of serial ports in response to queries of the variable hrDeviceStatus On some older UNIX systems serial port status queries can interfere with serial port based applications The SystemEDGE agent configuration file parameter no_serial_status enables this option SystemEDGE Agent Error Messages 461 not sending authen failure traps The SystemEDGE agent will not send MIB II authenFailure trap messages in response to SNMP queries that are using invalid community strings The SystemEDGE agent configuration file parameter no_authen_traps enables this option not stat ing disks devices The SystemEDGE agent will not check the status of disk devices according to the configuration file directive not stat ng floppy devices The SystemEDGE agent will not check the status of floppy disk devices according to the configuration file directive not stating NFS filesystems The SystemEDGE agent will not monitor or report statistics for NFS mounted filesystems On some UNIX systems attempts to ascertain the status of NFS mounted filesystems whose file servers are unavailable or down can indefinitely block the SystemEDGE agent Unfortunately programmatic o
361. o obtain the kernel name list or symbol table for the UNIX operating system that is running on the underlying system The agent will continue to operate but will be unable to report many kernel performance statistics and configuration parameters This error occurs when an alternative kernel is booted for example unix boot for testing purposes To fix this problem reboot with the unix kernel file eHealth SystemEDGE User Guide 460 e Appendix A Error Messages no extension variable found for X The SystemEDGE agent was unable to find an extension variable that corresponds to index x Extension variables are numbered from 1 through 32 This error message may occur if you attempt to add through the configuration file an extension variable whose number falls outside this range The SystemEDGE agent will ignore the configuration file statement and will continue to parse the configuration file For more information about extending the SystemEDGE agent refer to Chapter 16 Adding Custom MIB Objects non existent object to track history of An emphistory configuration file statement contains an invalid object identifier that is the object identifier does not exist within the SystemEDGE agent s MIB The agent will not create a History table entry and will ignore the statement The agent will however continue to parse the remainder of the configuration file no process matching expression The SystemEDGE agent was unable t
362. object s exact value Complete object instance identifier that represents the value to be monitored The instance portion of the object identifier for example 0 for scalars is required The object instance must exist and must be contained within the SystemEDGE agent s supported MIBs That is any supported integer based object that exists in MIB II the Host Resources MIB or the Systems Management MIB is valid Objects should be of integer type including counter gauge integer or enumerated integer Value that was last recorded for the MIB variable that is being monitored Every monInterval seconds the agent updates this field to reflect the latest value of the variable absoluteValue 1 The Monitor Table 249 Table 30 Columns of the Monitor Table Page 3 of 4 monOperator Read Write The operator type is a boolean operator that is used to evaluate the expression currval operator value The operator can be one of the following nop no operation monitor the object s value but do not evaluate the Boolean expression gt greater than lt less than gt greater than or equal to lt less than or equal to equal not equal monValue Read Write Integer value to which the current value of the monitored MIB variable is compared during each monitoring cycle If the comparison evaluates to True the agent sends a trap For example if you want to be notified if the value of a gauge goes
363. ocess Monitor Table 305 Table 43 describes the parameters of the watch process directive Table 43 Watch Process Parameters Page 1 of 2 attribute Process attribute that the SystemEDGE agent monitors for the specified threshold You may select any process attribute except procAlive from Table 38 on page 288 orocname Quoted string that specifies the regular expression to apply when attempting to match a process name and optional arguments Note Because the Windows kernel does not track the arguments used in a process the SystemEDGE agent does not match process arguments for Windows systems Row index to use for this entry flags Specifies any additional non default behavior to apply to this entry Specify all flags as hexadecimal numbers for example 0x0000 interval Interval that indicates how often in seconds the agent monitors the process Note This value must be a multiple of 30 stype Either absolute or delta this value indicates whether the agent should sample the process attribute s absolute value or take the difference between successive samples operator Operator type A Boolean operator that is used for evaluating the expression current value operator value The operator can be any of the following nop no operation gt greater than lt less than gt greater than or equal to lt less than or equal to equal not equal eHealth SystemEDGE User Guide 306 Chapter 11
364. ocol Anonymous FTP RFC 1157 Obsoletes RFC 1098 Case J McCloghrie K Rose M and Waldbusser S 1993 Textual Conventions for version 2 of the Simple Network Management Protocol SNMPv2 Anonymous FTP RFC 1443 Cockcroft A 1995 Sun Performance and Tuning Sparc e Solaris SunSoft Press Friedl J E F 1997 Mastering Regular Expressions Powerful Techniques for Perl and Other Tools O Reilly 1st edition Gookin D 1993 Batch Files and Beyond Your Path to PC Power McGraw Hill 4th edition Grillo P and Waldbusser S 1993 Host Resources MIB Anonymous FTP RFC 1514 529 926 e AppendixE Bibliography eHealth SystemEDGE User Guide Krupczak B 1993 UNIX Systems Management via SNMP In Proceedings of the IFIP TC6 WG6 6 Third International Symposium on Integrated Network Management Krupczak B 1995 Systems Management and the Internet Management Framework ConneXions The Interoperability Report 9 8 2 9 Leffler S J McKusick M K Karels M J and Quaterman J S 1989 The Design and Implementation of the 4 3 BSD UNIX Operating System Addison Wesley 2 4 edition Mauro D and Schmidt K 2001 Essential SNMP O Reilly McCloghrie K and Rose M T 1991 Management Information Base for network management of TCP IP based internets MIB II Anonymous FTP RFC 1213 Obsoletes RFC 1158 Microsoft 1995a Microsoft Windows NT Networking Guide Microsoft Pres
365. of 2 meee 0x00000001 Do not execute actions for this entry 0x00000002 Do not send traps for this entry This flag bit overrides any other flag bit with respect to traps 0x00000004 Do not attempt to reinitialize this entry By default if the monitored event log is unavailable the SystemEDGE agent periodically tries to reinitialize this table entry Setting this bit disables automatic reinitialization 0x00000008 Do not record events for this entry in the syslog utility Setting this bit does not affect the sending of traps or execution of actions On Windows systems the agent will not log the event to the agent s log file sysedge log When events occur frequently it is useful to disable event logging periodically attempts to reinitialize the entry Enabling this feature causes the agent to send an additional ntEventMonEntryNotReady trap each time reinitialization fails 0x00000010 Send continuous ntEventMonEntryNotReady traps for this entry every time the agent attempts to reinitialize event log monitoring and fails The agent s default behavior is to send a single ntEventMonEntryNotReady trap when the event log that it is monitoring ceases to exist or when an error accessing that event log occurs The agent 0x00000020 Do not pass SystemEDGE arguments to action scripts or programs SystemEDGE normally passes default action parameters that indicate the trap type description field and so on This flag disables the passing of those a
366. of a Process Group Monitor table entry requires two steps 1 Remove the entry from the sysedge cf file 2 Remove the entry from the Process Group Monitor table Removing Entries from the sysedge cf File If you configured a Process Group Monitor table entry by adding a watch procgroup directive to the sysedge cf file you must remove it from that file as part of removing the entry from the table If you do not remove the sysedge cf directive the entry will be recreated the next time the SystemEDGE agent is restarted eHealth SystemEDGE User Guide 332 e Chapter 12 Configuring Process Group Monitoring Removing Entries with the edgemon Utility To remove a process group monitoring entry from the Process Group Monitor table use the edgemon utility to delete the entry The following example deletes row 14 from the Process Group Monitor table on host 143 45 0 12 Once deleted the row will be removed both from memory and from the sysedge mon file edgemon 143 45 0 12 private procgroup delete 14 Removing Entries Manually eHealth SystemEDGE User Guide In some cases it may not be possible to use the edgemon utility to delete Process Group Monitor table entries For example if you have configured the SystemEDGE agent to disallow SNMP Set operations the edgemon utility will not work In this case you must remove the entry from the Process Group Monitor table by editing the sysedge mon file to remove the entry Because this is a
367. of streams e Number of stream allocation failures e Number of stream queues in use e Number of stream queue allocation failures e Statistics for stream message blocks and data blocks Streams Group 171 Table 18 describes the MIB objects in the Streams group and provides sample values for each Table 18 Streams Group MIB Objects maxmsgSize 1 Maximum streams message size in bytes 4096 bytes maxNumPush 2 Maximum number of stream modules that can be pushed at one time mblockMaxs 11 Greatest number of message blocks in use at one 187 time mblockFails 12 Number of streams message block allocation failures dblockUse 13 Number of streams data blocks currently in use dblockMaxs 14 Greatest number of data blocks in use at one time 187 dblockFails 15 Number of streams data block allocation failures 00 eHealth SystemEDGE User Guide 172 e Chapter 7 Systems Management MIB User Information Use the User table to retrieve information about the user accounts that have been created on the system Each row in this table represents a user account and contains columns that represent the following User s login name Password User ID Group ID User name User home directory Login shell NOTE Depending on your local security policies you may want to disable support for this table For more information about disabling this support refer to Configuring Support for User and Group Information on page 13
368. of the monitored object falls below the threshold the agent sends a processClear trap Sample Trap Sent ample No Trap Sent E Sample Clear Trap Sent uae Flags 0x00502400 Threshold Time Figure 44 Limiting the Number of Traps Sent Process Monitor Table Actions The SystemEDGE agent provides several default parameters to the action commands when they are invoked These parameters are in addition to any parameters that you specify in the action string and are passed on the command line after those that you specify The default parameters are the same as the parameters provided in the SNMP traps that are sent for the Monitor table Table 41 describes the default parameters for Process Monitor table actions eHealth SystemEDGE User Guide Process Monitor Table Actions 297 Table 41 Default Parameters for Process Monitor Table Actions trapType Type of trap that is being sent e processStop e processStart e processThreshold e processClear Index that is assigned to this table entry Table entry s description pmonAttribute Process attribute that is being monitored by this entry pmoncCurrVal Current value obtained for this table entry Operator that is being used by this table entry pmonValue Comparison value or threshold that is applied by this table entry pmonFlags Flags that are associated with this table entry pmonRegExpr Regular expression that the SystemEDGE agent uses to find the proce
369. ompts If you For example enter the following if you copied the enter invalid values or press Enter installation files to the opt EMPsysedge directory at a prompt that requires a value and does not offer a default cd opt EMPsysedge value the script will not complete properly If the script Be Cle IEE a Tian ee Orr You can change the configuration information after the unable to complete you must run ar 4 e ae fy valid installation if desired for more information refer to e script again and specify vali lt i Prag pecily Chapter 4 Configuring the SystemEDGE Agent The values for all prompts post installation script also enables automatic licensing of the agent For information about additional ways to license the agent refer to Chapter 3 Licensing the SystemEDGE c gt Agent Install NOTE For a detailed example of the installation script refer to Installing SystemEDGE on HP UX Systems on page 75 For each prompt the default value is shown in brackets You can press Return to accept the default or you can enter another value and then press Return Installing SystemEDGE on AIX Systems This section describes how to install the SystemEDGE agent on AIX systems See the Preface for a list of supported systems and versions System Requirements Before you begin installing the agent verify that your system meets the following requirements e CD ROM drive At least
370. on 1 man page 91 edgemon exe 93 edgemon txt 93 edgewatch utility arguments 312 command arguments 346 directory 90 error messages 474 examples 313 348 introduction 300 parameters 310 346 syntax 310 345 using 345 eHealth SystemEDGE User Guide edgewatch 1 man page 91 edgewatch exe 93 edgewatch txt 93 eHealth 40 eHealth application insight modules 39 eHealth for Cisco CallManager 38 eHealth Service Availability 37 eHealth Voice Quality Monitor 38 email exe 90 93 emphistory directive example 386 parameters 386 syntax 385 emphistory utility description 90 error messages 478 Man page 91 overview 387 parameters 387 emphistory exe 93 emphistory txt 94 empire asn 1 97 enable disk performance statistics on Windows 208 enterprise system object identifier 215 error messages actions 439 authentication failure 439 command line utilities 472 descriptions 439 edgemon utility 472 edgewatch utility 474 emphistory utility 478 invalid PID 440 nteventmon utility 479 sendtrap utility 481 snmpget utility 483 sysvariable utility 484 xtrapmon utility 486 event logs criteria for searching 359 monitoring 360 examples edgewatch utility 313 348 extending Systems Management MIB 396 Extension group 396 history monitoring 389 log file monitoring 348 ntRegPerf group 409 process group monitoring 330 process monitoring 306 threshold monitoring 264 watch logfile 344 watch ntevent 371 Windows event monitoring 371 375 executing remote
371. on while processing the ISAPI Application watch ntevent 136 0x148 System All 29 The server failed to shutdown application watch ntevent 137 0x148 System All 37 Out of process application terminated unexpectedly watch ntevent 167 0x8 System Error EDB Monitor MSSQL Server Database t Events watch ntevent 168 0x8 Security Error EDB Monitor MSSQL Server Database Events eHealth SystemEDGE User Guide i E E EHA HHHH HEHEHEH HHHH o H H H HHH E HHHH H H Sample sysedge cf File 123 watch ntevent 169 0x8 Application Error EDB Monitor MSSQOQL Server Database Events 1 watch ntevent 170 0x8 Application All 1 Event ID 1 watch ntevent 171 0x8 Application All 2 Event ID 21 TI Watch ntevent 172 0x8 Application All 4 Event ID 4 11 watch ntevent 173 0x8 Application All 5 Event ID 5 Log file monitoring entries are defined below each line instructs the agent to watch a given log file for a given regular expression see man ed 1 for more details on regular expression syntax Usage watch logfile index flags logfilename regexpr description action Examples Note these are examples from Unix systems NT does not use text logfiles to record operating system messages You could use this however for application logfiles watch logfile 1 0x8 var
372. onfiguring the History Control Table 387 Using the emphistory Utility Use the emphistory utility from the command line to add delete set the status of or list entries in the History Control table You can also use it with the dump operation to retrieve stored data samples from the History table You can use the emphistory utility as follows emphistory add ipaddr port commstr ctrlIndex objid interval buckets i GSSCcripe1on emphistory delete ipaddr port commstr ctrlIndex emphistory list ipaddr port commstr emphistory setstatus ipaddr port commstr ctrlIndex status emphistory dump ipaddr port commstr ctriIndex Table 74 describes the parameters for the emphistory utility Table 74 emphistory Utility Parameters Page 1 of 2 ipaddr port IP address or hostname of the system on which you want to set the table optionally followed by the port on which the agent is running If the SystemEDGE agent is running on a port other than 161 you must specify a value for port commstr SNMP community string to use when performing the specified command To perform add delete and setstatus operations the community string on the target agent must have have read write access For the list and dump operations the community string needs only read access err iindex Row number for this entry in the agent s History Control table Rows are indexed starting at 1 When you specify the dump operation the agent retrieves all data
373. onitoring 0 cece eee cece eee ence eee 245 Th Monitor Naples seatuoegenenesensnseeeneedeeee eens 246 Sample Entry in the Monitor Table 246 Columns of the Monitor Table 2 4 247 Optimizing Row Creation 0 0 ce eee eee eee 251 Monitor Table Flags 0 0 eee cee eee eee eens 252 Monitor Table Actions 244240sc2de0G0e yess euenideeadeecd 255 Viewing the Monitor Table with AdvantEDGE View 256 Assigning Entry Rows for the Monitor Table 257 Seting Local PONCy c si aevtsetasdsree scat eeseeiaees 257 Reserving Blocks of ROWS 00 e cece eee eee eee eee 258 Configuring the Monitor Table 0 2 2 0 2 00 ee 258 Initial Configuration During Startup 259 Dynamic Configuration During Operation 261 Adding Entries with the monitor Directive 261 Threshold Monitoring Examples 0e eee eee 264 Monitoring the 1 Minute Load Average 264 Monitoring the 5 Minute Load Average 265 Monitoring the 15 Minute Load Average 266 Monitoring the System s Interrupt Rate 267 Monitoring the System s Page Fault Rate 268 Monitoring Number of Incoming Packets on the Interface 270 Monitoring Number of Outgoing Packets on the Interface 270 Monitoring Number of SNMP Packets Received 271 Monitoring Space on t
374. operations waiting milliseconds Disk Statistics Group 209 Table 26 Disk Statistics Group MIB Objects Page 2 of 2 diskStatsReads Total number of read operations diskStatsWrites Total number of write operations diskStatsHostmibDevTableIndex Index of this disk in the Host Resources MIB Device table diskStatsLastUpdate Time of last stats update When you are using the Disk Statistics table refer to the diskStatsLastUpdate column for information about the time in TimeTicks that this row was last updated This column lets you know whether the statistics have been updated since you last queried the table The values for diskStatsQueueLength diskStatsServiceTime and diskStatsUtilization are all calculated over the interval between updates Enabling Collection of Disk Performance Statistics For Windows and AIX systems you must manually configure the systems to collect disk performance statistics The SystemEDGE agent can monitor these statistics only if you instruct the operating system to track them NOTE Enabling the collection of these statistics decreases the disk throughput Windows Systems This section describes how to enable and disable the collection of disk statistics for Windows systems eHealth SystemEDGE User Guide 210 e Chapter 7 Systems Management MIB To enable collection of disk statistics for Windows systems 1 3 Log in to the system you want to monitor as an administrat
375. or Enter the following at the command prompt diskperf y Restart the system To disable collection of disk statistics for Windows systems 1 3 Log in to the system you want to monitor as an administrator Enter the following at the command prompt diskperf n Restart the system AIX Systems This section describes how to enable and disable the collection of disk statistics for AIX systems To enable collection of disk statistics for AIX systems 1 eHealth SystemEDGE User Guide Log in to the system you want to monitor with root privileges Enter the following at the command prompt chdev 1 sys0 a iostat true CPU Statistics Group 211 To disable collection of disk statistics for AIX systems 1 Login to the system you want to monitor with root privileges 2 Enter the following at the command prompt chdev 1 sys0 a iostat false CPU Statistics Group The CPU Statistics group provides performance statistics for each CPU Each table entry provides the latest statistics for one CPU The agent periodically every 60 seconds checks the status of the system data structures for each CPU and records the values in the table Table 27 describes the CPU Statistics MIB objects Table 27 CPU Statistics Group MIB Objects Page 1 of 2 cpuStatsSys Total number of ticks spent in System mode Total number of ticks spent in Wait mode cpuStatsLastUpdate Time of last update cpuStatsIdlePercent Pe
376. or table refer to Chapter 15 Configuring History Collection Configuring User Group Permissions for Subprograms UNIX Only eHealth SystemEDGE User Guide By default the SystemEDGE agent runs subprograms for example remote shell action and extension object invocations with its effective user and group permissions normally root Depending on the local security policies in effect at your site you may want to set the agent to use actions and extension objects that run with different user and group permissions To run subprograms with the effective user and group permissions of a user other than root add the following statements to your SystemEDGE agent configuration file subprogram_user_name concord subprogram_group_name sysmgmt In these examples all subprograms execute with the effective permissions of the user concord and group sysmgmt The user and group names that you specify must be valid on the underlying system Configuring the SNMP Bind Address 143 NOTE If either the user name or group name is incorrect SystemEDGE disables all subprogram functionality That is the agent does not support actions extension MIB objects and remote shell capabilities Configuring the SNMP Bind Address By default SystemEDGE binds to all interfaces UDP 161 You can change the port to which SystemEDGE binds by using the p option when you invoke SystemEDGE or you can bind SystemEDGE to a specific interfac
377. or Linux Systems 154 Starting the Agent Automatically for AIX Systems 154 Starting the Agent Automatically for Digital UNIX r Lrao4 Systems erener rinra eter heey erwunbae 155 eHealth SystemEDGE User Guide Chapter 6 Chapter 7 Table of Contents 7 Logging Agent Operation Messages 020 eee ee 155 Logging Messages for UNIX 00 ee eee eee 155 Logging Messages for Windows 2 ee eee 156 Using the SystemEDGE Agent with Other SNMP Agents 157 Supporting Multiple SNMP Agents 0 0 ce eee eee 157 Agent Multiplexing 0 cece eee eee eee ence 158 Monolithic Agents 0 0 cece cece eee eee ence 159 Using the SystemEDGE Agent with the Solstice Enterprise Agent 65 6 o5 355 06s Gibu sas tbudeeeteoei es ae edn 160 Using the SystemEDGE Agent with the Microsoft Windows DN MP AGGIE 664500 5454 46400 0 ede one ees Gane eae eens 161 Using the SystemEDGE Agent with the HP SNMP Agent 162 Using the SystemEDGE Agent with the AIX SNMP Agent 163 Using the SystemEDGE Agent with the Digital UNIX or THUGS SNMP ACCW occ ee ok oan eee es EE seer 163 Using the SystemEDGE Agent with the Compaq Insight Manager 2 62 0 246ecer wie eater konaa eke ean ee 164 Systems Management MIB 165 Host System Information 0 ccc cece eee eee eee 166 Mounted Devices sees ane Seen ses eee eerenes eee gee ees 167 Monitoring File System Space 2 cece eee ee eee 168
378. or equal to equal not equal pmonValue Read Write Integer value to which the current value of the monitored process attribute is compared during each monitoring cycle If the comparison evaluates to True the agent sends a trap For example if you want to be notified if the value of a gauge goes above 100 set 100 as the pmonValue to which the agent compares the current value of the gauge eHealth SystemEDGE User Guide 286 e Chapter 11 Configuring Process and Service Monitoring Table 37 Columns of the Process Monitor Table Page 3 of 4 a Only Time based on sysUpTime at which the agent last sampled called the process attribute it is monitoring 0 indicates that the MIB variable has not yet been sampled pmonNumtTraps Read Only Number of traps that have been sent for this entry This column provides a useful metric for determining the frequency at which the exception condition is occurring and a means for detecting missed trap messages pmonLastTrap Read Only Time based on sysUpTime at which the agent last sent a trap for this entry 0 indicates that no traps have been sent pmonFlags Read Write Integer flags value that indicates additional behavioral semantics this row should follow during the course of its operation The default is 0x00 For more information about this field refer to Process Monitor Table Flags on page 289 pmondAction Read Write Quoted string that is 0 to 256 characters in length and tha
379. ormation about SNMP DPI refer to RFC 1592 For more information about SMUxX refer to RFC 1227 eHealth SystemEDGE User Guide The two most common multiplexing protocols are SNMP Distributed Protocol Interface DPI and SNMP multiplexing SMUX SNMP DPI is an extension to SNMP agents that permits users to dynamically add delete or replace management variables in the local MIB through a subagent without having to recompile the SNMP agent SMUX is a session management protocol that provides a lightweight communication channel from the underlying transport layer to the application layer by multiplexing data streams on top of a reliable stream oriented transport Neither protocol is standard or dominant in the marketplace The IETF is currently working on a standardized approach based on SNMP DPI called AgentX These RFCs define only the protocol that is used between Master and subagent They do not define a set of APIs Because the specifications for DPI and SMUX are publicly available an agent developer can implement a master or subagent that conforms to either specification without encountering licensing and royalty fees when using them with another vendor s master or subagent However because neither protocol is standard an agent developer has to support both protocols to ensure the greatest amount of master slave agent multiplexing interoperability Supporting Multiple SNMP Agents 159 Monolithic Agents Several proprietary
380. ot perform the operation For example UNIX systems do not support the NT Event Monitor table so operations to the NT eHealth SystemEDGE User Guide 478 e Appendix A Error Messages Event Monitor table that are targeted to SystemEDGE agents that are running on UNIX systems will generate this error message Verify your target hostname or IP address to ensure you are targeting a Windows system unknown NT event log name An invalid Windows event log name was passed to edgewatch for NT Event Monitor table manipulation so no operation was performed Verify that the event log name is valid on the target system unknown NT event type An invalid Windows event type was passed to edgewatch for NT Event Monitor table manipulation so no operation was performed Verify that the event type name is valid on the target system emphistory Error Messages eHealth SystemEDGE User Guide This section describes error messages that may be generated by the emphistory utility bogus port number The optional SystemEDGE agent port number that was provided to emphistory was invalid and either contained non numeric symbols or was negative The requested action therefore was not performed cant resolve address The address or hostname that was provided to emphistory could not be resolved to a valid IP address so the requested action was not performed Verify that the provided hostname has a valid address through tools like host or nslookup
381. ot query the SystemEDGE agent To resolve this problem you must verify that the agent is running that it is properly configured and that the management system software is properly configured eHealth SystemEDGE User Guide 426 e Chapter 19 Troubleshooting and Usage Suggestions eHealth SystemEDGE User Guide Is the SystemEDGE Agent Running You can verify that the agent is running in one of the following ways using the diagsysedge exe program or using netstat For information about using diagsysedge exe refer to Determining Whether the Agent Is Running on page 423 To verify that the agent is running with netstat 1 Enter netstat a and look for UDP 161 UDP 1691 or SNMP 2 Enter ps aux orps aef and look for sysedge 3 Examine system log files for agent error messages e On Windows examine SystemROOt system32 sysedge log e On UNIX examine the syslog files Is the SystemEDGE Agent Starting at System Initialization To verify that the agent is started at system initialization e Check the UNIX startup script e Make sure that the SystemEDGE service is configured for automatic startup Is the SystemEDGE Agent Responding to Queries Use the sysvariable utility to query a system and prove that the agent is responding to queries You must specify the port number unless you are using the default port of 161 for the SystemEDGE agent and the community string for your system For example to display the op
382. otal strbufAllocFail 0 0 16 0 0 fs 0 1 1 Ge 0 16 254714 0 2 2 128 5 a0 117340 0 3 E a 0 4 18375 0 4 4 1024 22 163 120475 0 5 5 2048 0 4 1665 0 E 6 8192 0 1 483 0 T T 16777215 0 4 a 0 Figure 11 Systems Management MIB Sample Streams Buffer Allocation Table I O Buffer Cache Use the I O Buffer Cache group to track I O buffer allocation and usage for basic disk I O You can also graph the values of these counters to detect peak periods of I O buffer activity Table 20 describes the I O Buffer Cache group MIB objects Table 20 I O Buffer Cache Group MIB Objects Page 1 of 2 numBreadRequests 1 Total number of buffer read calls that were made 1121570 numBreadHits 2 Number of kernel buffer cache hits 1047985 numBufSleeps 3 Total number of times kernel had to sleep for a buffer numAgeAlloc 4 Total number of times an aged buffer was 15423 allocated eHealth SystemEDGE User Guide RPC Group 185 Table 20 I O Buffer Cache Group MIB Objects Page 2 of 2 numLRUAIloc 5 Total number of times an LRU buffer was 88217 allocated minNumBufHdrs 6 Minimum number of buffer headers allocated o numAllocBuf 7 Current Current number of allocated buffers of allocated buffers Canaan Percentage ee read requests that are found in the buffer cache RPC Group Use the Remote Procedure Call RPC Group to track statistics and counters that relate to the use of the kernel s RPC facilities You can graph the values of
383. out FTP User Tiame out 1 watch mtevent 120 0x8 Application Error 5 Error File Unexpected error tI watch ntevent 122 0x8 Application All 4101 An object call caused an exception watch ntevent 123 0x8 Application All 4131 A server process failed during initialization watch ntevent 124 0x148 Application All 4153 An exception occurred within a Resource Dispenser watch ntevent 125 0x148 Application All 4180 MTS recorder is out Of memory Unable to allocate new resources watch ntevent 126 0x148 Application All Failover 1 The following IP address was added to target monitoring list watch ntevent 127 0x148 Application All Failover 2 The following IP address was added to target monitoring list watch ntevent 128 0x148 Application All Failover 4 Event ID 4 watch ntevent 129 0x148 Application All Failover 5 Event ID 5 watch ntevent 130 0x148 System All 301 Out of Virtual Memory Please close some applications Watch ntevent 131 0x148 System All 10010 The server did not register with DCOM within the required time out watch ntevent 133 0x148 System All 14 The HTTP Filter DLL failed to load The data is the error watch ntevent 135 0x148 System All 19 The HTTP server encountered an unhandled excepti
384. ovides a powerful mechanism for extending the Systems Management MIB to include a wide range of information on your systems and applications Using this feature you can extend the agent to manage your unique system environment more effectively You can also design application specific MIB variables that allow you to manage your applications using SNMP without implementing SNMP support within the application source Systems Management MIB Extension Group The SystemEDGE agent provides this extension support through the Extension group extensionGroup of the Systems Management MIB This group contains unspecified scalar MIB variables that you can configure In response to a SNMP GetRequest for one of these variables the SystemEDGE agent invokes the command that you specify for the variable and returns the value that is returned from the command Using the SNMP Set operation you can also pass parameters to a command The Extension group is supported on both UNIX and Windows systems on Windows however you may also need to configure the agent to report on performance and configuration data that is contained in the Windows registry To support this reporting the SystemEDGE agent also provides a Windows registry 391 392 e Chapter 16 Adding Custom MIB Objects extension group For more information about this group refer to Chapter 14 Configuring Windows Event Monitoring Figure 56 shows four sample extension variables that are d
385. ovides examples for using the watch logfile directive Searching for pop Connection Attempts The following example instructs the SystemEDGE agent to add a new entry to the Log Monitor table at table index 15 to search for pop connection attempts on a system watch logfile 15 0x00 var log syslog popper NOTICE pop connection TI eHealth SystemEDGE User Guide Using the edgewatch Utility to Monitor Log Files 345 Searching for su Attempts The following example instructs the SystemEDGE agent to add a new entry to the Log Monitor table at table index 16 to search for su attempts on a system watch logfile 16 0x02 var adm messages su fail WARNING su attempt local bin mail2admin The 0x02 flag specifies that the agent should not send traps Instead the agent invokes the specified action command Dynamic Configuration During Operation The agent uses the SNMPv2 SMI You can use your management system to issue SNMP Set Row Status textual conventionfor request messages to the SystemEDGE agent in order to modify creating deleting and modifying the entries in the Log Monitor table Log Monitor table entries rows in the table For more are saved to the SystemEDGE agent s sysedge mon OS configuration file This ensures that any changes made during convention refer to Appendix E the operation of the agent are preserved across agent and system restarts NOTE Configuration file directives in sysedge cf take precedence o
386. p Agent RPC Server RPC E E E E amp E E E E EE E E E E H H H HH Sample sysedge cf File 125 watch process procAlive pcmsvc32 PCMSVC32 417 0x8 60 SMS Package Command Manager NT watch process procAlive wuser32 WUSER32 418 0x8 60 SMS Remote Control Agent watch process procAlive timeserv TIMESERV 419 0x8 60 Time Service watch process procAlive wins WINS 420 0x8 60 WINS service watch process procAlive dns DNS 421 0x8 60 WINS DHCP watch process procAlive mqsvc MOQSVC 438 0x8 60 MS Message Queue Service watch process procAlive clicfg CLICFG 443 0x8 60 SMS Client Config Manager watch process procAlive smsexec SMSEXEC 444 0x8 60 SMS Executive watch process procAlive preinst PREINST 445 0x8 60 SMS Hierarchy Manager watch process procAlive invwin32 INVWIN32 446 0x8 60 SMS Inventory Agent NT TI watch process procAlive siteins SITEINS 447 0x8 60 SMS Site Config Manager watch process procAlive sqlservr SQLSERVR 448 0x8 60 SQL Server watch process procAlive sqlexec SQLEXEC 449 0x8 60 SQL Executive watch process procAlive db2serv DB2SERV 452 0x8 60 Monitor db2serv Service watch process procAlive tn3servr TN3SERVR 456 0x8 60 Monitor TN3270 Service watch process procAlive iexplore IEXPLORE 457 0x8 60 IE Alive C sysedge contrib restartproc bat watch process procRSS iexp
387. p tables uncomment the following line in sysedge cf by removing the pound sign character from the following line no_usergroup_table Configuring Support for Remote Shell Capability By default the SystemEDGE agent supports the Remote Shell group which allows management systems to remotely instruct the agent to execute shell scripts and programs on the system on which the agent is running For more information refer to Chapter 7 Systems Management MIB Because the disclosure of this type of information could pose a potential security risk you might want to disable the agent s support for this information To disable support for the Remote Shell Group uncomment the following line in sysedge cf by removing the pound sign character from the following line no_remoteshell group eHealth SystemEDGE User Guide 134 e Chapter 4 Configuring the SystemEDGE Agent Configuring Alternative Syslog Facilities UNIX Only The SystemEDGE agent by default logs all syslog messages to the LOG_DAEMON syslog facility You can specify a different facility in the configuration file NOTE _ Windows does not support the syslog facility On Windows systems all syslog output is logged by default to the SystemRoot system32 sysedge log file If you are using Windows refer to the next section Configuring Alternative Syslog Facilities Windows Only The following example sends the SystemEDGE agent
388. page 262 interval Specifies an integer value 30 to MAXINT that indicates how often in seconds the monitoring should be performed For example the value 30 instructs the agent to monitor this entry every 30 seconds Note This value must be a multiple of 30 seconds eHealth SystemEDGE User Guide Using the edgemon Utility to Monitor Thresholds 277 Table 36 edgemon Command Parameters Page 2 of 2 stype Specifies sample type of either absolute or delta This value indicates whether the agent should sample the object s absolute value or take the difference between successive samples oper Specifies the boolean operator to use when comparing the sampled value to the threshold value The operator can be one of the following nop gt greater than lt less than gt greater than or equal to lt less than or equal to equal not equal aon the integer value threshold to which the current value of the o MIB variable is compared descr Specifies a quoted string that is 0 to 128 characters in length and that normally contains a description of the object that is being monitored as well as a severity level taction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the expression evaluates to True and a trap is sent If the string is empty no action is performed for this entry Specifies the name o
389. page of the eHealth Support Web site For more information refer to the next procedure To access the Software Downloads page of the eHealth Support Web site hon In your Web browser go to http support concord com Enter your user name and password then click Login Select downloads The Software Downloads page appears Click the product that you want to download A Web page appears listing the available versions of that product Click the Instructions link for installation instructions and then the Software Package link to begin downloading the SystemEDGE agent or eHealth AIMs to your system eHealth SystemEDGE User Guide 416 e Chapter 18 Deploying the SystemEDGE Agent Deploying SystemEDGE through E mail You can deploy the SystemEDGE agent eHealth AIMs and other modules to your users through e mail To do so copy the installation package file the readme txt file and the user guide from your AdvantEDGE CD ROM and e mail them to the user You can modify the readme txt file as necessary for your deployment Third Party Deployment Tools For new systems most vendors provide automated installation tools that can install third party software at operating system installation time Table 81 lists some recommended programs for automating operating system installation Table 81 Recommended Automated Operating System Installation Programs Sun JumpStart Migration Kit http www sun com HP Ignite U
390. per process e Kernel version description string Boot Configuration 169 Table 16 provides sample values for each MIB object in the Kernel Configuration group Table 16 Kernel Configuration Group MIB Objects maxProcs 1 138 serialNumber 2 romVersion 3 clockHZ 5 100 kernelVers 6 virtualMem 7 68596 KB maxInode 8 322 maxFiles 9 582 maxClist 10 228 maxMemPerProc 11 13852 KB totalSwap 12 65516 KB openMaxPerProc 13 256 posixJobCtrl 14 true 1 posixVersion 15 198808 pageSize 16 4096 Boot Configuration You can use the MIB objects in the Boot Configuration group to determine which device and partition the system is using for the root file system the dump file system and swap space as well as the number of blocks contained by each eHealth SystemEDGE User Guide 170 e Chapter 7 Systems Management MIB Streams Group eHealth SystemEDGE User Guide Table 17 provides sample values for the MIB objects of the Boot Configuration group Table 17 Boot Configuration Group MIB Objects rootName 1 rootFSType 2 rootBlocks 3 0 dumpBlocks 6 The Streams I O subsystem provides a data transit processing path between applications in user space and drivers in kernel space in the host You can monitor the health of the Streams subsystem by retrieving objects that provide the following types of information e Maximum stream message size e Number of streams in use e Maximum number
391. perf pageScans errorTable ipc buffers mbuf buffers strbuf ioBufferCache numBufSleeps ioBufferCache numAgeAllocs ioBufferCache numLRUAllocs ioBufferCache numBufHdrs ioBufferCache numAllocBuff dnlc ntRegistry ntRegistryCurrentSize rpc nfs eHealth SystemEDGE User Guide 202 e Chapter 7 Systems Management MIB Monitor Table The Monitor table enables you to dynamically configure the agent s self monitoring capability to monitor any integer based MIB variable under its control you select the polling interval comparison operator greater than less than equal to and so on and threshold value The agent automatically monitors the MIB variable for you and notifies the management system with a trap message if an exception occurs The Monitor table allows you to specify an entry for any MIB variable within MIB II the Host Resources MIB and the Systems Management MIB As the agent is running the entries in the Monitor table also show information such as the following Time at which the variable specified by the entry was last sampled e Value of the variable e Lowest and highest values observed e Number of times that a trap has been sent for the entry Figure 15 shows examples of some conditions that you can configure the agent to monitor eo SNMP Table Display Table monitorTable Path 1 5 6 1 4 1 546 6 1 1 Rows 10 Columns 16 monDescr monInterval monSamp leType monOID monCurr al monOperato
392. presents the UNIX SIGKILL signal which can kill a process Figure 7 shows a sample Process table Process Information 175 e SNMP Table Display Table processTable Path 1 5 6 1 4 1 546 1 1 4 1 Rows 10 Columnss11 Instance processID processName processState processNice processFlags processUID processGID processkill processSize processRSS processTime 128 128 Imgrd il 20 537427968 0 0 0 72 0 0 129 129 screenblank 1 20 524288 0 0 0 16 0 1 139 139 islandLIC 1 20 536903680 0 0 0 132 0 1 142 142 rpc yppassudd 1 20 557056 0 0 0 44 0 0 147 147 update il 20 524801 0 0 0 12 8 244 150 150 cron 1 20 4751360 0 0 0 56 0 0 156 156 inetd al 20 557056 0 0 0 52 0 Z 160 160 lpd 1 20 557056 0 1 0 52 0 0 331 331 csh 1 20 541622784 6168 10 0 68 0 0 398 398 snmpd 3 20 541622273 0 1 0 260 232 28 a af Figure 7 Systems Management MIB Process Table Changing the nice Value of a Process UNIX only This section explains how to change the nice value for a specific process To change the nice value of a process Find the row that represents the selected process 2 Set the processNice column in that row to the desired nice value priority For a list of values refer to the UNIX nice 1 man page eHealth SystemEDGE User Guide 176 e Chapter 7 Systems Management MIB Sending a Signal to a Process When you are performing SNMP Set operations use a community name that allows you read write access This section expl
393. procedure is specific to your management system and MIB compiler 4 Import the new empire asn1 file into your management system software This procedure is specific to your management system and MIB compiler NOTE If you do not reimport the MIB file your management system software will not be able to access the new extension MIB objects Editing a Separate MIB Specification for Extension Variables You can place extension variables in a separate MIB specification file for ease of updating In this way you can save time and effort by making changes to a MIB specification file that is much smaller than empire asn1 instead of recompiling and reloading the entire empire asn1 file To add your extension variables to a separate MIB specification file 1 Create and debug the relevant extension scripts and configure them in the agent s configuration file sysedge cf to include them eHealth SystemEDGE User Guide 2 Recommendations for Using Extensions 401 Edit your own MIB specification file for example extensions asn1 to include new extension MIB variables that exist under the Systems Management Extension group Perform a test compile of extensions asn1 to ensure that there are no syntax errors This procedure is specific to your management system and MIB compiler Import the extensions asn1 file into your NMS software This procedure is specific to your management system and MIB compiler NOTE If you do not rei
394. pt action commands when the table row evaluates to True eHealth SystemEDGE User Guide 454 e Appendix A Error Messages fork failed for logmonitor action The SystemEDGE agent failed to fork itself in order to execute the Log Monitor action Fork failures occur if the system has insufficient resources to create new processes This error indicates that no Log Monitor action was executed but the Log Monitor table row is still active and will continue to attempt action commands when the table row evaluates to True FPE signal caught The SystemEDGE agent caught a floating point exception error probably because of a divide by zero error Report this message to eHealth Technical Support ID is X Y On Windows systems the SystemEDGE agent reports its process X and thread Y identifiers in its log file This message is for debugging purposes only and can be ignored identical threads IDs On Windows systems the SystemEDGE agent has discovered two separate distinct threads with the same thread identifier Although this condition is technically impossible it can still occur This message indicates that the SystemEDGE agent has discovered this situation and has properly accommodated it invalid extension variable access mode eHealth SystemEDGE User Guide The extension statement in the SystemEDGE agent configuration file contains an invalid access mode Valid access modes are read only or read write indicating whether an exten
395. ptions to prevent this are not possible The SystemEDGE agent configuration file parameter no_stat_nfs_filesystems enables this option not supporting actions The SystemEDGE agent is not supporting actions according to the configuration file directive not supporting remoteShell group The SystemEDGE agent will not support SNMP queries Gets and Sets to the remoteShell group because local system security policies prohibit this functionality The SystemEDGE agent configuration file parameter no_remoteshell_group enables this option eHealth SystemEDGE User Guide 462 e Appendix A Error Messages not supporting user group tables The SystemEDGE agent will not support SNMP queries to the User and Group tables because local system security policies prohibit the dissemination of valid user and group information The SystemEDGE agent configuration file parameter no_usergroup_table enables this option not supporting who table The SystemEDGE agent will not support SNMP queries to the Who table because local system security policies prohibit the dissemination of currently logged in users The SystemEDGE agent configuration file parameter no_who_table enables this option nteventmon entry X not ready The SystemEDGE agent has sent an NT Event Monitor trap message that indicates that entry x is notReady The SystemEDGE agent will no longer perform Windows event monitoring on behalf of the NT Event Monitor table entry x but
396. questing a usage based license set duration to the number of months for which the license is valid h Set the values for proxy proxyport proxyuser and proxypasswd if you are using an authenticated proxy to access the Internet eHealth SystemEDGE User Guide 114 e Chapter 3 Licensing the SystemEDGE Agent i In the section Comment out plugins which are not desired place a pound sign in front of the modules for which you do not want to obtain licenses Modules are named as follows sysedge is the SystemEDGE agent svcrsp is eHealth Service Availability xchgmod is eHealth AIM for Microsoft Exchange lismod is eHealth AIM for Microsoft IIS apachemod is eHealth AIM for Apache oramod is eHealth AIM for Oracle sqlmod is eHealth AIM for Microsoft SQL Server netsvcmod is eHealth AIM for Network Services firewall is eHealth AIM for Check Point FireWall 1 ccmmod is the eHealth for Cisco CallManager module mosmod is the eHealth Voice Quality Monitor module j Set OS to either UNIX or Windows depending on the type of operating system that you are using 4 Save and close licenseutil pl 5 Open the hostlist file in a text editor edit it to include the hostnames or IP addresses of the systems to license and then save and close the file 6 Run licenseutil p by entering the following at the command line licenseutil pl auto hostfile community port timeout product eHealth SystemEDGE User Guid
397. r for that process being monitored would no longer exist and the agent would send a monitorEntryNotReady trap to all properly configured managers 3 eHealth SystemEDGE User Guide 218 e Chapter 8 Private Enterprise Traps logMonMatch Trap eHealth SystemEDGE User Guide The following code shows the format of a logMonMatch trap which the SystemEDGE agent sends to indicate that the log file monitoring subsystem has detected a match in a log file that the agent is currently monitoring logMonMatchEvent OBJECT IDENTIFIER traps 4 logMonMatchTrap TRAP TYPE ENTERPRISE empire VARIABLES lLogMonitorLogFile logMonitorRegularExpression logMonitorLastTrap logMonitorLastMatch logMonitorDescr logMonitorIndex logMonitorFlags DESCRIPTION This trap is sent when the log monitoring subsystem detects a match in a log file it is currently monitoring Periodically the agent Stats each log file for changes if any changes have occurred the agent scans only those changes for a pattern match Pattern matches result in logMonMatch events Changes to log files occur when new entries are added by syslogd 1M or other logging daemons 4 Format of Trap PDUs 219 logMionNotReady Trap The following code shows the format of a lgMonNotReady trap which the SystemEDGE agent sends to indicate that the status of an entry in the Log Monitor table has changed to notReady logMonNotReadyEvent OBJECT IDENTIFIER tr
398. r IG Hast ysiog P i 20 31 54 action Add Log Monitor Entry Figure 52 Sample AdvantEDGE View Log Monitor Table eHealth SystemEDGE User Guide Configuring the Log Monitor Table 343 Configuring the Log Monitor Table You can control which log files the SystemEDGE agent monitors by adding deleting or modifying entries in the Log Monitor table You can configure the Log Monitor table in the following ways Dynamically Use SNMP commands from a management system such as AdvantEDGE View to modify the table For more information refer to Dynamic Configuration During Operation on page 345 At start up initialization Specify the entries for the Log Monitor table in the SystemEDGE agent configuration file sysedge cf For more information refer to the next section Initial Configuration During Start Up Initial Configuration During Start Up On start up the SystemEDGE agent reads the sysedge cf configuration file and uses the watch logfile directive to specify initial entries to the Log Monitor table You can add entries to the sysedge cf file to specify the text files that you want the agent to monitor Using the watch logfile Directive You can use the watch logfile directive to add entries in the Log Monitor table as follows watch logfile index flags logFilename logMonRegExpr logMonDescr logMonAction eHealth SystemEDGE User Guide 344 e Chapter 13 Configuring Log File Monitoring
399. r Table 298 Dynamic Configuration During Operation 299 Initial Configuration During Startup 300 Monitoring a Process to Make Sure It Is Running 302 Using the watch process Directive to Monitor Process IDO ese k canoe gerd gueens aeagoe are eee 304 Process Monitoring Examples 000 cece eee 306 Using the edgewatch Utility to Monitor Processes 310 edgewatch Commands for Process Monitoring 312 edgewatch Examples 0 cee cece eee e ence eens 313 Removing Process Monitoring Entries 315 Removing Entries from the sysedge cf File 315 Removing Entries with the edgemon Utility 316 Removing Entries Manually 02 022 ee 316 Recommendations for Process and Service Monitoring 317 Configuring Process Group Monitoring 319 Monitoring Process GroupS 0 eee eee eee eee 319 The Process Group Monitor Table 006 320 Columns of the Process Group Monitor Table 320 Optimizing Row Creation 0 0 cece eee eee 324 Process Group Monitor Table Flags 05 325 Process Group Monitor Table Actions 2 45 326 eHealth SystemEDGE User Guide 12 e Table of Contents Chapter 13 Viewing the Process Group Monitor Table with AdvantEDGE VIEW ssscrcrccerercreredo etare cetaree inesi 327 Assigning Entry Rows for the
400. r ee agent updates the sysedge mon file to record the changes This information about the textual file preserves changes that are made during the operation of the conventions for row status refer S EDGE J hich Appendix E ystemEDGE agent across agent and system restarts whic means that if the agent is stopped it can restart with the same Monitor table configuration NOTE Configuration file directives in sysedge cf take precedence over entries in sysedge mon For example if a Monitor table entry is contained in sysedge mon at index 10 and a configuration file directive for index 10 of the Monitor table is added to sysedge cf the entry in sysedge cf replaces the entry from sysedge mon Adding Entries with the monitor Directive Use the monitor keyword to add entries to the Monitor table as follows monitor attribute monIndex monFlags monInterval monSampleType monOperator monValue monDescr monAction eHealth SystemEDGE User Guide 262 e Chapter 10 Configuring Threshold Monitoring Table 34 describes the parameters for the monitor directive Table 34 Monitor Directive Parameters Page 1 of 2 attribute One of the following e oid variable name The word oid followed by an OID to be monitored You can specify the OID using the complete dotted decimal value for example 1 3 6 1 2 1 25 1 5 0 or the symbolic MIB name for example hrSystemNumUsers 0 Either way you must specify the object instance which is normally zero
401. r expressions refer to the UNIX man page on egrep 1 logMonitorAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the regular expression is matched and a trap is sent If the string is empty no action will be performed for this entry logMonitorFlags Unsigned integer flags value indicating additional behavioral semantics this row should follow during the course of its operation By default this field is assigned the hexadecimal value 0x00 For more information about this field refer to Chapter 14 Configuring Windows Event Monitoring eHealth SystemEDGE User Guide Sample Log Monitor Entry in sysedge mon 507 Table 89 Fields for Log Monitor Table Entries Page 2 of 2 logMonitorRowsStatus One of the following e active e notInService notReady e createAndGo e createAndWait Normally a row is either active or notInService These values are identical in meaning to the SNMPv2 SMI RowsStatus textual convention For more information refer to Appendix E End of the entry is marked by a closed bracket Sample Log Monitor Entry in sysedge mon This section includes an example for adding an entry to the Log Monitor table through the sysedge mon file Monitoring for Failed su Attempts The following entry instructs the SystemEDGE agent to monitor the var adm messages log file for the expression su fail
402. r monValue 1 minute load average 60 absolute alue 1 loadAveragelMin 0 0 gt 2 300 5 minute load average 300 absoluteValue 1 loadAverageStin 0 5 gt lt 2 200 15 minute load average 900 absoluteValue 1 loadAveragelSMin 0 ill gt 2 200 Interrupt Rate 60 deltaValue 2 gt numInterrupts 0 25741 gt 2 10000 Page fault Rate 60 deltaValue 2 numPageFaults 0 0 gt 2 1000 le Incoming Packets 60 deltaValue 2 if InUcastPkts 2 0 gt 2 1000 le Outgoing Packets 60 deltaValue 2 ifOutUcastPkts 2 0 gt 2 1000 SNMP Packets 30 deltaValue 2 snmpInPkts 0 49 gt lt 2 4000 Num Processes 60 absoluteValue 1 hrSystemProcesses 0 46 gt 2 120 fusr filesystem 60 absoluteValue 1 devCapacity 4 78 ge 4 90 a e anf OK ert Fae eHealth SystemEDGE User Guide Figure 15 Systems Management MIB Sample Monitor Table Process Monitor Table fe SNMP Table Display Table processMonTable Process Monitor Table 203 For more information about using the Monitor table and SystemEDGE threshold monitoring refer to Chapter 10 Configuring Threshold Monitoring The Process Monitor table provides a powerful and flexible mechanism for monitoring applications and processes This capability allows you to monitor various attributes of key processes and applications and to send SNMP traps when certain thresholds have been exceeded Figure 16 shows a sample Process Monitor table Path 1 3 6 1 4 1 546 15 1 1 Rows 9 Columns318 pmonIndex
403. r the UNIX ypbind daemon on the underlying system watch process procAlive ypbind 16 0x00000000 60 Monitor ypbind example pager sh eHealth SystemEDGE User Guide Configuring the Process Monitor Table 309 The values in this example are defined as follows e 16 indicates that this entry will occupy row 16 pmonIndex 16 in the Process Monitor table e 60 indicates that the agent should check the ypbind process every 60 seconds e The agent invokes the specified action script example pager sh each time it sends a trap In this case it invokes the script each time a processStop or a processStart trap is sent The script should examine its arguments to determine which trap is being sent and then send the appropriate message to the target pager Monitoring the Size of a Process The following example configures the SystemEDGE agent to monitor the overall size of a particular process watch process procSize netscape 20 0x00a02400 60 absolute gt 35000 Monitor netscape size The values in this example are defined as follows e procsSize is the attribute that the agent is monitoring It returns the size of text data and stack segments of the corresponding process Monitoring this attribute for a given threshold will allow you to determine if it is leaking memory or growing unbounded netscape indicates the name of the process that the agent will monitor e 20 indicates that this entry will occupy row 20
404. rations refer to Dynamic Configuration During Operation on page 299 Configuring the Process Monitor Table 301 To specify process attributes to monitor 1 Select the process and attribute to monitor The process and attribute you select must be supported by the SystemEDGE agent and implemented on the platform on which the agent is running For a list of supported variables refer to the MIB specifications in the doc subdirectory of the SystemEDGE agent distribution Assign the entry to a free row in the table by selecting the index number Decide on the sample type if the attribute you want to monitor is a counter use deltaValue For other integer values gauge enumerated integer integer and so on use absoluteValue Decide on the threshold and operator type against which the agent should compare the monitored variable s current value The agent uses the following comparison expression the agent current value operator value Valid values for operator are described in Table 37 on page 284 Select an appropriate value for comparison To help determine an appropriate value monitor the object for a period of time to find a normal value The choice of this value is critical and depends on the semantics of the object you are monitoring If you want to receive processClear traps enable that feature through the pmonFlags field For more information refer to Table 37 on page 284 Select a monitor interval
405. rcentage of sample time spent in Idle mode eHealth SystemEDGE User Guide Extension Group Table 27 CPU Statistics Group MIB Objects Page 2 of 2 cpuStatsUserPercent Percentage of sample time spent in User mode cpuStatsSysPercent Percentage of sample time spent in Sys mode cpuStatsWaitPercent Percentage of sample time spent in Wait mode When you are using the CPU statistics table refer to the cpuStatsLastUpdate column for information about the time in TimeTicks that this row was last updated This column also lets you know whether the statistics have been updated since you last queried the table The values for cpuStatsIdlePercent cpuStatsUserPercent cpuStatsSysPercent and cpuStatsWaitPercent are all calculated over the interval between updates The Extension group provides a powerful mechanism for extending the Systems Management MIB to include a wide range of information on your systems and applications This group contains 2 unspecified scalar MIB variables that you can configure In response to an SNMP Get request for one of these variables the SystemEDGE agent invokes the command that you specify for the variable and returns the value that is returned from the command Using an SNMP Set operation you can also pass parameters to a command Figure 19 shows the organization of a sample Extension group Extension Group 213 extensionUomainNamet1 extensionnNisServerte extensionGroup 14 extension
406. rd 00 e eee ences 393 Additional Parameters 20640856 neaenes nad oawestentus 394 Extension Examples 0 0c ccc cence cece ene nen e nee 396 DNS Domain UNIX Only 0 00 cece eee ee eee 396 NIS Domain Name UNIX Only 00 00 0008 396 Remote Pinger UNIX and Windows 000 397 Writing Extension SChptS 40 426s405 chee ine eseoetaee iowa 397 Using Extension Variables with Your Management Software 399 Editing empire asn1 for Extension Variables 400 Editing a Separate MIB Specification for Extension VariaDleSes an caeneadgonennss eeit IRE Rarna 400 Recommendations for Using Extensions 00 401 Adding Windows Registry and Performance MIB Objects 403 Systems Management MIB ntRegPerf Group 403 Windows Registry and Performance Functionality 404 ReSistty Dala ence ya Ge gies eae bade oe ee eevee ean nes 405 Performance Wald cascvesaqanetees Cumeneend eweseeeewe 405 Configuring Windows Registry and Performance Variables 408 Using the ntRegPerf Keyword 0 cee eee eee 408 Windows Registry and Performance Examples 409 CrashControl DumpFile 00 0 cece cee eae 409 Objects Trci eeri 56452 ceeden ss bonpcude yew ex ane 410 PCP Segments SeO SCC perierit reak oes veseds basen gees 410 Using Windows Registry and Performance Variables with Your Management Software 2 cece cece eee cee eens 410
407. rd at the password prompt 2 Insert the CD that contains the software distributions into the CD ROM drive If you are running volume management the CD is mounted automatically If you are not running volume management you must mount the CD by entering the following command mount r t hsfs dev rdsk c0Ot6d0s2 cdrom For more information about volume management refer to the man page for vold 1M eHealth SystemEDGE User Guide Installing SystemEDGE on Solaris Systems 53 NOTE The CD ROM device depends on whether the device is Integrated Drive Electronics IDE or Small Computer System Interface SCSI and on the particular SCSI ID setting if applicable For more information about the CD ROM device refer to your system documentation 3 Run the pkgadd utility to install the software For Solaris SPARC systems enter the following pkgadd d cdrom sysedge sol For Solaris x86 systems enter the following pkgadd d cdrom sysedge so1x86 The installation script displays the following message Concord SystemEDGE Agent post installation starting When you run the installation This script enables you to configure the SystemEDGE script you must enter valid agent You can change the configuration information after values for all prompts If you the installation if desired for more information refer to enter invalid values or press Enter Chapter 4 Configuring the SystemEDGE Agent The at a prompt that requires
408. rguments For more information about action parameters refer to the next section NT Event Monitor Table Actions 0x00000040 Do not send notReady traps for this entry eHealth SystemEDGE User Guide 366 Chapter 14 Configuring Windows Event Monitoring Table 65 Common Monitor Table Flags Page 2 of 2 Fag Descnption 0x00000100 Pre append the Event ID number to the event description field The identifier is added using the form where is the identifier The purpose of this flag is to facilitate searches for specific Event IDs For example to specify that only Event ID 528 should match specify this flag with the ntEventMonDescFilter set to 528 0x00000200 Send every event except the specified event When you enable this flag the agent applies matches to expressions and does the following if the match is true it sets it to false and if the match is false it sets it to true If the results are true the agent performs the specified action or sends a trap Note Use caution in setting this flag Ox 0000 Flag value 0x00010000 Oxffff0000 The NT Event Monitor Table does not utilize this flag value field setting it has no effect on the NT Event Monitor Table operation or on any of the supported flag bits NT Event Monitor Table Actions The SystemEDGE agent provides several default parameters to the action commands These parameters are in addition to any parameters you specify in the action string and
409. roduct ID Directory path where the software resides Run time parameters with which the software was started Type of software for example operating system or application Status of the software for example running runnable not runnable or invalid Figure 28 shows part of an hrSWRunTable for a Sun SPARC IPX system eHealth SystemEDGE User Guide 242 e Chapter 9 Host Resources MIB e SNMP Table Displa Table hrSWRunTable hrSWRunIndex Path 1 3 6 1 2 1 25 4 2 1 Rows310 Columns37 hrShRunName hrSWRunID hrShRunPath hrSWRunParameters hrSWRunType hrSWRunStatus UNIX Swapper null operatingSystem 2 runnable 2 init null fsbin init fsbin init application 4 runnable 2 UNIX Pager null operatingSystem 2 runnable 2 portmap null portmap portmap application 4 runnable 2 ypserv null ypserv ypserv application 4 runnable 2 gt ypxfird null ypxfird ypxfird application 4 runnable 2 ypbind null ypbind ypbind application 4 runnable 2 rpc ypupdated null rpc ypupdated rpc ypupdated application 4 runnable 2 keyserv null keyserv keyserv application 4 gt runnable 2 in routed null in routed q in routed q application 4 runnable 2 gt LY ert Fae Figure 28 Sample Host Resources Running Software Table Host Resources Installed Software Group eHealth SystemEDGE User Guide The hrSWInstalledTable lists the software that is currently installed on the host system For each software package
410. rrier error no carrier Warning link is down Link Down cable problem Error SDS error T_NOTICE WARNING PANIC md eHealth SystemEDGE User Guide Recommendations for Log File Monitoring 353 Table 59 provides recommendations for regular expressions for which you can search in var adm messages to monitor system capacity Table 59 Monitoring System Capacity Critical memory error O o ut of M m emory Error diskspace error No space left on device Table 60 provides recommendations for which logs and expressions you can monitor in the Windows event logs to monitor Windows security Table 60 Monitoring Windows Security Misuse of Privileges Security user rights group management security change restart shutdown Virus Calta Warning Security write exe dll com program files updated Security Policies Change Application S s ecurity policy eHealth SystemEDGE User Guide 354 e Chapter 13 Configuring Log File Monitoring Table 61 provides recommendations for which logs and expressions you can monitor in the Windows event logs to monitor applications and systems Table 61 Monitoring Applications and Systems Server Process failed eer Application All 4131 Initialization Network Adapter Errors a e i N n etwork A a dapter Monitoring Log File Size To monitor the size of a log file add a log file monitoring entry to sysedge cf for an artificial expression and t
411. rs the process group descripcion Quoted string that is 0 to 128 characters in length and that normally contains a description of the process group that is being monitored action Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to execute when a match is found for the process group If the string is empty the agent invokes no action for this entry eHealth SystemEDGE User Guide 330 e Chapter 12 Configuring Process Group Monitoring Process Group Monitoring Examples This section contains sample configuration file directives for process group monitoring Monitoring the xterm Process Group The following example configures the SystemEDGE agent to monitor the xterm process group watch procgroup xterm 10 0x00 60 Watch xterms The values in this example are defined as follows e 10 indicates that this entry will occupy row 10 pgmonIndex 10 in the Process Group Monitor table The flags field value of 0x00 indicates the default behavior e 60 indicates that the agent should check the xterm process group every 60 seconds e No action is specified so the agent invokes no command when it sends a trap Monitoring the emacs Process Group The following example configures the SystemEDGE agent to monitor the emacs process group watch procgroup emacs xmibmgr 11 0x00 60 Watch emacs The values in this example are defin
412. running the utility It also requires SNMP Set permission to the target agent It uses SNMP to query the license information from the target agent automatically fills out the online Web based licensing form retrieves the resulting license key and uses an SNMP Set to configure that key to the target agent The target agent then saves the license key to its license file You can run licenseme interactively or invoke it with scripts eHealth SystemEDGE User Guide 110 e Chapter 3 Licensing the SystemEDGE Agent To run the licenseme utility 1 Change to the directory where you installed the SystemEDGE agent for example opt EMPsysedge or C sysedge 2 Enter the following at the command prompt bin licenseme The licenseme utility prompts you for your account information on the licensing Web site http license concord com Once you have provided this information the program contacts the Web site and retrieves the license for you If you have a valid read write community string configured licenseme saves the license for you and automatically enables full SystemEDGE agent operation For information about configuring a read write community string refer to Chapter 4 Configuring the SystemEDGE Agent NOTE You can use the licenseme program to license SystemEDGE agents that are installed on remote systems If you have only one system that has access to the Web you can run licenseme on that system and direct it to license
413. rwrite the configuration files Instead it copies the new files to the config subdirectory The following dialog box appears a 1 Concord SystemEDGE installation is almost complete SystemEDGe Files are in place Click OK to continue with setup and licensing options 7 Click OK The following dialog box appears 8 Click Yes to disable the Microsoft SNMP agent or No to run both agents The following dialog box appears eHealth SystemEDGE User Guide 64 e Chapter 2 nstalling the SystemEDGE Agent Information G SystemEDGE will need to establish several parameters For Functionality 9 Click OK The following dialog box appears System Description Please enter the following details describing your system Description My Test System Contact Me Location My office InstallShield lt Back Henst gt Cancel 10 Specify a description contact name and system location in the Description Contact and Location fields and then click Next eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 65 11 Click Yes to extract SNMP configuration information from the Microsoft SNMP agent or No if you want to configure the SystemEDGE agent to use different community strings and trap destinations The following dialog box appears InstallShield Wizard SystemEDGE SNMP Port Please select a port number for SystemEDGE to employ for SNMP Fort 161
414. ry extension objects of type x because the agent cannot understand it There is no way to map it to an SNMPv1 object type The agent will not support this registry extension object CreateEvent for traps failed On Windows systems the SystemEDGE agent must create an internal operating system event resource for use with sending SNMP traps This error message indicates that the event creation failed Consequently the SystemEDGE agent may not be able to send private enterprise trap messages createMutex failed for query mutex On Windows systems the SystemEDGE agent uses an operating system mutex resource for controlling access to structures shared with the master agent Consequently the SystemEDGE agent may not be able to operate properly createMutex failed for result mutex On Windows systems the SystemEDGE agent uses an operating system mutex resource for controlling access to structures shared with the master agent Consequently the SystemEDGE agent may not be able to operate properly eHealth SystemEDGE User Guide 444 e Appendix A Error Messages dev lan is missing SystemEDGE cannot continue The SystemEDGE agent requires a dev lan device to run on HP UX systems It will not start if it cannot find that device Instead it will log a message to syslog and exit For information about the device refer to your HP UX documentation dkiotime read failed no disk stats The SystemEDGE agent was unable to read a disk sta
415. s Microsoft 1995b Microsoft Windows NT Resource Kit Microsoft Press Rose M 1991a SNMP MUX Protocol and MIB Request for Comments Proposed Standard RFC 1227 Internet Engineering Task Force Rose M and McCloghrie K 1990 Structure and Identification of Management Information for TCP IP based Internets Anonymous FTP RFC 1155 Obsoletes RFC 1065 Rose M T 1991b The Simple Book An Introduction to Management of TCP IP Based Internets Prentice Hall 1 edition Sun Microsystems Inc 1988 RPC Remote Procedure Call Protocol Specification Version 2 Anonymous FTP RFC 1057 Sun Microsystems Inc 1989 NFS Network File System Protocol Specification Anonymous FTP RFC 1094 Sun Microsystems Inc 1990 SunOS Reference Manual Sun Microsystems Vol II edition e 527 Wijnen B Carpenter G Curran K Sehgal A and Waters G 1994 Simple Network Management Protocol Distributed Protocol Interface Version 2 0 Request for Comments Proposed Standard RFC 1592 Internet Engineering Task Force Obsoletes RFC1228 eHealth SystemEDGE User Guide A access communities configuring 128 default 130 setting 49 lists specifying 129 actions configuring support 137 default parameters Log Monitor table 340 Monitor table 255 NT Event Monitor table 366 Process Group Monitor table 326 Process Monitor table 296 error messages 439 Log Monitor table 341 Monitor table 256 NT Event Monitor
416. s ntServicePathName ntServiceStartType Service start type for example Automatic ntServiceParameters Start parameters ntServiceState Current state ntServiceObjectName_ Current user name that the service is using eHealth SystemEDGE User Guide Windows Specific Groups 193 NT System Performance Group The NT System Performance group provides statistics that enable you to track the health and performance of the system s Windows operating system Specifically performance counters in the System Performance group let you see the following e How much time the processor s spent in user and privileged modes e Number of context switches that have taken place e Number of system calls and interrupts e Number of jobs in the scheduler s run queue e Performance counters for file system operations such as the number of read write and control operations and the total number of KB for each Figure 12 shows the organization of the NT System Performance group ntSystemPerf 1 ntCachePerf 2 ntPerformance 5 ntMemoryPerf 3 ntPageFilePerf 4 monitorTable 1 _ _ _ monitorEntry 1 rec 1 nfs 2 empireHistoryCtr1Table 1 empireHistoryCtrlEntry 1 empireHistoryTable 2 empireHistoryEntry 1 Figure 12 NT System Performance Group ntTotalPrivTime lt 1 ntTotalProcessorTime 2 ntTotalUserTime 3 ntAlignFixups 4 ntContextSwitches 5 nt
417. s often service several requests and then exit In these cases it is preferable to monitor the main parent daemon rather than the child processes Enabling this feature causes the agent to search for and monitor the parent daemon rather than the first process it finds that matches the process regular expression The agent performs this search as follows It scans the Process Monitor table for processes that match the name of the process regular expression pmonRegExpr If the matching parent process of the process also matches the agent returns the parent process This searching algorithm only accommodates parent child relationships and cannot handle daemons forking daemons This feature is not available on Windows systems because the notion of parent child processes does not exist on Windows Note You cannot set this flag if you are using the 0x00000800 flag eHealth SystemEDGE User Guide Process Monitor Table Flags 293 Table 40 Process Monitor Table Flags Page 3 of 4 Pag Deserition 0x00000200 Do not send processStart traps for this entry If this feature is enabled the agent sends processStop traps and logs events unless those features were disabled through their corresponding flags bits 0x00000400 Send processClear traps for this entry when a process monitor expression transitions from True to False This feature is only applicable when the attribute being monitored is not procAlive Figure 41 on page 294 shows how to
418. s running Windows This message indicates that the SNMP query that was used in that verification process failed and that no NT Event Monitor table entry was created The SNMP query may fail if the corresponding packets are dropped or if the target agent is not a SystemEDGE agent nteventmon internal error please report An internal SNMP library error has occurred within the program Report this error to Technical Support by sending an e mail to support concord ca com nteventmon unknown NT event log name The Windows event log name that was passed to nteventmon was invalid Valid event log names include the following application security and system Try the command again with a valid Windows event log name nteventmon unknown NT event type The Windows event type password to nteventmon was invalid Valid Windows event types include the following error warning info information succ success fail failure or all Try the command again with a valid Windows event type nteventmon WSAStartup failed On Windows systems nteventmon was unable to initialize the WinSock library and could not communicate with the targeted SystemEDGE agent The requested action therefore was not performed Returned system type is not integer nteventmon first attempts to verify that the target machine is running Windows This message indicates that the SNMP query that was used in that verification process returned a non integer value There
419. s to be executed when the expression evaluates to True and a trap is sent If the string is empty no action will be performed for this entry pmonRowStatus One of the following active notInService notReady createAndGo createAndWait Normally a row is either active or notInService These values are identical in meaning to the SNMPv2 SMI RowStatus textual convention For more information refer to Appendix E End of the entry is marked by a closed bracket Sample Process Monitor Entries in sysedge mon This section includes examples for adding entries to the Process Monitor table through the sysedge mon file eHealth SystemEDGE User Guide 902 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Monitoring the Netscape Process Run Status The following entry in the sysedge mon file instructs the SystemEDGE agent to monitor the netscape process every 60 seconds If the process is down the agent sends an SNMP trap message processmon 1 Monitor netscape alive 60 absoluteValue procAlive eq 4 0x0 uw netscape active Monitoring the Netscape Process Size eHealth SystemEDGE User Guide The following entry in the sysedge mon file instructs the SystemEDGE agent to monitor the memory utilization of the netscape process every 2 minutes 120 seconds If the process RSS value exceeds 50000 a SNMP Trap message is sent processmon 2 Monitor netscape RSS 60 absoluteValue procRss gt
420. s XP and Windows 2003 SystemEDGE Agent Binary sysedge sol27 sysedge sol28 sysedge sol29 sysedge sol210 sysedge dll Common Problems and Questions 433 Bind Failed Address Already In Use If a bind fails because the address is in use the SystemEDGE agent displays a message similar to the following when it first starts sysedge bind call failed Address already in use sysedge another agent is probably running on port X This message most often occurs when another SNMP agent is already up and running and is bound to port UDP 161 which is the default well known SNMP agent port For more information about using the SystemEDGE agent with other SNMP agents refer to Chapter 6 Using the SystemEDGE Agent with Other SNMP Agents For more information about using SystemEDGE on an alternative UDP port refer to Chapter 5 Starting the SystemEDGE Agent Updating the Monitor Configuration File The sysedge mon monitor configuration file serves as non volatile backing store to the agent s in memory self monitoring tables When SNMP updates are made to any of the agent s in memory self monitoring tables those tables are written to sysedge mon Consequently the agent does not interpret updates to sysedge mon that occur it is running until it is restarted Also updates made to sysedge mon while the agent is running may be lost if the agent writes its in memory monitor table over the tables in sysedge mon In addi
421. s an SNMP Set to each agent that is defined in your hostlist file populating its sysedge lic file and each agent becomes fully licensed NOTE You can run the licenseutil pl script interactively or with the cron command If you use cron you must update the hostlist file but you do not need to perform any other tasks Agents that are running in restricted mode will be licensed and will enter full mode Agents that are already licensed are not affected by the script They will continue to run as before eHealth SystemEDGE User Guide Configuring the SystemEDGE Agent This chapter describes how to set configuration parameters that the SystemEDGE agent reads on startup These configuration parameters are defined in the sysedge cf text file and they specify local system values such as the following e System description community strings and trap communities e Agent behavior for reporting or not reporting security related information and running or not running action scripts Entries for the agent s self monitoring tables The sysedge cf file is located in the etc UNIX or SystemRoot system32 Windows directory For Windows systems you can also access sysedge cf through the SystemEDGE Control Panel by selecting Start Settings gt Control Panel eHealth SystemEDGE and then clicking sysedge cf on the SystemEDGE Control Panel NOTE Whenever you modify the sysedge cf file you must stop and restart the SystemE
422. s each system s sysedge lic file with those licenses using an SNMP Set The script requires a freely available Perl LWP module for WWW manipulation Obtaining a License Key 113 Before You Run licenseutil pl 1 Install the SystemEDGE agent and any plug in modules 2 Start the SystemEDGE agent It starts in restricted mode 3 Determine whether you want to run licenseutil pl from a system that is connected to the Internet or from a system that is not connected to the Internet Using licenseutil pl from a System that is Connected to the Internet 1 Ensure that the system on which you want to run licenseutil p has connectivity to all of the systems that require licenses as well as to the Internet 2 Change to the sysedge contrib directory and unzip the licensetools file The distribution includes licenseutil pl sample host files and license files and Perl modules for Perl SNMP queries 3 Open the licenseutil pl file in a text editor and provide values for the following variables a Set username to your licensing user name b Set passwd to your licensing password c Set enduser to the name of the end user company if you are requesting a usage based license d Set name to your name e Set email to your e mail address f Ifthe type of license that you are selecting is anything other than permanent set licensetype to one of the other values partner evaluation or usage based g If you are re
423. s file systems both local and remote For each file system the table lists the following Local mount point Remote mount point if the file system is being mounted from a remote machine Type of file system for example BerkeleyFFS Whether the file system allows read write or read only access Figure 27 shows sample output of the hrFSTable for a Sun SPARC IPX eHealth SystemEDGE User Guide Host Resources Running Software Group 241 e SNMP Table Display Table hrFSTable Path 1 35 6 1 2 1 25 3 8 1 Rows310 Columns 6 hrFSMountPoint hrFSRemoteMountPoint hrFSType hrFSAccess hrFSStorageIndex f hrFSBerkeleyFFS readhlrite 1 gt 3 fusr hrFSBerkeleyFFS readhrite 1 4 fat22 hrFSBerkeleyFFS readhrite 1 5 fnet hrFSOther readOnly 2 0 tmp_mnt net htL morticiat htl hrFSNFS readWrite 1 gt 0 ftmp_mnt net usr local sun4 4 1 3 morticiat usr local hrFSNFS readWrite 1 gt 0 ftmp_mnt net atl morticiat at1 hrFSNFS readhrite 1 0 tmp_mnt net mai 1 morticiat usr spool mail hrFSNFS readlrite 1 gt 0 ftmp_mnt net other trantor datal other hrFSNFS readhrite 1 0 tmp_mnt net local5 lennont u2 local5 hrFSNFS readhrite 1 0 lt i p OK esta Figure 27 Sample Host Resources File System Table Host Resources Running Software Group The hrSWRunTable lists the software that is currently running on the host system For each running software process the table lists the following Unique identification number Name P
424. s for starting the SystemEDGE agent The usage options are as follows sysedge b d f configfile l licensefile p port h t eHealth SystemEDGE User Guide Starting the Agent Automatically at System Boot 151 Table 13 describes the UNIX command line options for starting the SystemEDGE agent Table 13 UNIX Command Line Options for Starting the SystemEDGE Agent Run the agent in the background The SystemEDGE agent runs as a daemon process and disconnects from the controlling terminal Use this flag when starting the SystemEDGE agent from a startup script so Run the agent in debug mode This option causes the agent to log debug level messages with the syslog facility For more information about syslog refer to Appendix B f configfile Read configuration parameters from the configfile file instead of the default etc sysedge cf file Display help for the command This option lists the available command line options Use the license key licensefile file instead of the default etc sysedge lic file m monitorfile Use the Monitor table configuration file monitorfile instead of the default etc sysedge mon file p port Listen for incoming SNMP messages on port instead of on the standard SNMP port 161 CA has reserved UDP 1691 for use as an alternate port for running the SystemEDGE agent t Run the agent in packet trace mode This option causes the agent to write a packet dump of each SNMP PDU received or trans
425. s monitoring and fails to match a process The agent s default behavior is to send a single processStop trap when a process dies and then attempt to periodically reinitialize the entry Enabling this feature causes the agent to send an additional processStop trap each time reinitialization fails In all cases the agent does not send processStart and processStop traps unless the corresponding entry is monitoring the procAlive process attribute Note This flag is valid only when the agent is monitoring the procAlive attribute When you are monitoring Windows services an entry does not enter the notReady state when the service is not running Setting this flag causes SystemEDGE to generate processStop traps and execute any associated actions for the entry when the service is not running even though it remains in the ready state 0x00000020 Do not pass SystemEDGE arguments to action scripts or programs SystemEDGE normally passes default action parameters that indicate the trap type description field and so on This flag disables the passing of those arguments For more information refer to Process Monitor Table Actions on page 296 0x00000040 Do not send notReady traps for this entry 0x00000100 Monitor the parent process in the process group Many applications and services for example Web server httpd daemons are designed such that an initial daemon spawns child processes to handle actual service requests These child processe
426. s row 14 from the Log Monitor table on system 143 45 0 12 Once deleted the row will be removed both from memory and from the sysedge mon file edgemon 143 45 0 12 private logfile delete 14 Removing Entries Manually eHealth SystemEDGE User Guide In some cases it may not be possible to use the edgemon utility to delete Log Monitor table entries For example if you have configured the SystemEDGE agent to disallow SNMP Set operations the edgemon utility will not work In this case you will need to remove the entry from the Log Monitor table by editing the sysedge mon file and removing the entry from the file Because this is an active file you must stop the SystemEDGE agent before you edit it For more information on the format of this file refer to Appendix C For example to delete row 14 1 Stop the SystemEDGE agent 2 Open sysedge mon for editing delete the entry for logmon row 14 and save the file 3 Open sysedge cf for editing delete the entry for logmon row 14 if it exists and save the file 4 Restart the SystemEDGE agent Recommendations for Log File Monitoring 351 Recommendations for Log File Monitoring You can monitor system and application logs to obtain in depth information about user system and application behavior The following tables provide recommendations for which log files you can monitor and the regular expressions for which you can search for monitoring security device failures syste
427. s supported for the version of the operating system you are using refer to the eHealth SystemEDGE Release Notes Unsupported MIB Objects on Windows Systems The SystemEDGE agent for Windows supports the Host Resources MIB RFC 1514 but some of the MIB objects within this MIB module are not supported by the underlying Windows operating system Those objects therefore cannot be implemented by the Windows version of the agent eHealth SystemEDGE User Guide 244 e Chapter 9 Host Resources MIB eHealth SystemEDGE User Guide The following Host Resources MIB objects are not supported on Windows systems hrSystemInitialLoadParameters hrStorageAllocationFailures hrDeviceID hardware manufacturers have not assigned IDs hrDeviceErrors hrProcessorFrwID manufacturers have not assigned IDs hrPrinterTable not implemented in current release hrFSRemoteMountPoint hrFSLastFullBackupDate hrFSLastPartialBackupDate hrFSAccess hrFSBootable not implemented in current release hrSWRunEntry SWRunPath hrSWRunEntry SWRunParameters hrSWInstalledID Configuring Threshold Monitoring The SystemEDGE agent can also monitor processes process groups log files and Windows events This chapter explains how to use the SystemEDGE agent to monitor MIB variables against user specified thresholds Threshold Monitoring The SystemEDGE agent includes a flexible Monitor table through which you can dynamically configure the agent to moni
428. s the row in the History Control table of which this sample is a part that is it has the same value as the empireHistoryCtrlIndex for the corresponding entry in the control table empireHistorySampleIndex Index that uniquely identifies the particular sample this represents among all samples that are associated with the same history control entry This index starts at 1 and increases by one as each new sample is stored empireHistoryStartTime Time based on sysUptime at which the first sample was taken empireHistorySampleTime Time based on sysUptime at which this particular sample was taken empireHistoryValue Current value of the MIB variable taken at this sample Optimizing Row Creation You can use the following scalar MIB objects with the History table to optimize row creation Table 72 Scalar Objects for Optimizing Row Creation iki histCtrlUnusedIndex Read Only You can use this variable to optimize table row creation for the History table Perform an SNMP Get of this variable to return an unused index number for the History table histCtrIMatchDescr Read Write You can use this MIB object with the histCtrIMatchIndex MIB object to determine the index number that corresponds to a particular entry description Perform an SNMP Set of this MIB object to cause the agent to search through entries in the History table and place the index value of the last entry whose description matches in the histCtrl MatchIndex
429. s the self monitoring tables that are provided in the Systems Management MIB These tables configure the SystemEDGE agent s autonomous self monitoring and data storage capabilities Table 2 Systems Management MIB Monitor Tables Monitor table Specifies MIB objects that the SystemEDGE agent monitors and compares to user specified thresholds Process Monitor table Specifies processes that the SystemEDGE agent monitors for status whether they are running and resource utilization Process Group Monitor table Specifies groups of processes that the SystemEDGE agent monitors for status and resource utilization Log Monitor table Specifies regular expression strings for which the SystemEDGE agent searches through user specified log files NT Event Monitor table Specifies event logs that the SystemEDGE agent searches for specific events History Control table Specifies the sample interval and number of samples for MIB objects that the SystemEDGE agent monitors and stores in the History table for future retrieval by the management system eHealth SystemEDGE User Guide Using eHealth SystemEDGE 31 For more information about how the SystemEDGE agent uses the Systems Management MIB refer to Chapter 7 Systems Management MIB SystemEDGE Self Monitoring Features When you manage a large enterprise network with hundreds of systems you may need to place limits on the information that is monitored the poll rate
430. s to guide titles or text that is emphasized enter Text that you must type exactly as shown Text that refers to menus fields in dialog boxes or keyboard keys New Term Text that refers to a new term that is one that is being introduced Variable Text that refers to variable values that you substitute gt A sequence of menus or menu options For example File gt Exit means Choose Exit from the File menu NOTE Important information tips or other noteworthy details CAUTION Information that helps you avoid data corruption or system failures WARNING Information that helps you avoid personal physical danger eHealth SystemEDGE User Guide 26 e Preface Technical Support If you have a Support Contract ID and password you can access our Support Express knowledgebase at the following URL http search support concord com If you have a software maintenance contract you can obtain assistance with eHealth For online technical assistance and a complete list of primary service hours and telephone numbers contact Technical Support at http support concord com Current SystemEDGE Product Information For the most current information about the SystemEDGE agent and related products refer to the SystemEDGE page on the eHealth product Web site at http www concord com sysedge eHealth SystemEDGE User Guide Introduction eHealth SystemEDGE increases the productivity of system administration staff
431. s to perform capacity planning accurately document service problems and troubleshoot potential problems For more information refer to the eHealth System and Application Administration Guide Figure 2 shows a sample AAG report for systems Using eHealth with eHealth SystemEDGE 41 At a Glance Report SystemEDGE NT System Element BOTANY SH CPU Utilization by Process Set E BOTANYBAY SH eHealth E BOTANYBAY SH ingres i BOTANYBAY SH S emEDG Esgent E BOTANYBAY SH FirstSenseAgent E BOTANYBAY SH McShield Total CPU Utilization CPU Run Queue Length processes 25 SM laf li Mid rr rs rs rs es Availability by Process Set BOTAN ErstSenscpert F irstSen e geni McShield EEE eHealth m SEEMED EAE t mSS E 0 E 1 89 90 94 p 95 00 100 System Availability 100 E O O O _ t lt t FF t Physical Memory by Process Set bytes 100M 0 20M es 2000 N o a a a a ay a BM BOTANYBAY SH eHealth E BOTANYBAY SH Ingres E BOTANYBAY SH Ss mEDG Eage it E BOTANYBAY SH FirstSenseAgent E BOTANYBAY SH McShield Physical Memory Used Total Physical Memory Virtual Memory bytes 600M 5 aaaaammmmmmmmmmmmmmmmmmmmmmms 200M E a __1 _a Total ij Used Page Faults page faults sec 250 2 eee re a a S a Pages In pages sec 60 20 ee Pars A J vr 1 Pd S s s s s Ra R ib 5 x Na r X Auto Range Yes
432. samples from the History table that correspond to the entry in the History Control table identified by ctrlIndex If you specify a ctrlIndex value of 1 for dump operations the agent retrieves all contents of the History table You must specify a ctrlIndex value for add operations in order to specify the particular MIB table index of an unused row to use for row creation eHealth SystemEDGE User Guide 388 e Chapter 15 Configuring History Collection Table 74 emphistory Utility Parameters Page 2 of 2 elo vir Complete object instance identifier of the MIB variable that the agent will sample and store in the History Control table You can specify the OID using the complete dotted decimal value for example 1 3 6 1 2 1 25 1 5 0 or the symbolic MIB name for example hrSystemNumUsers 0 You must provide the instance portion of the OID that is 0 for scalars The object instance must exist and must be of integer type which includes counter gauge integer or enumerated integer Interval in seconds between successive samples this value must be a multiple of 30 seconds buckets Number of discrete data samples to be saved in the History table on behalf of this control entry Each sample called a bucket contains the snapshot value of the MIB variable the time at which the sample was created the sample index and an index that corresponds to the entry in the History Control table that defines the data collection function The History
433. scover the devices contained in the underlying system using whatever operating system support is available This error messages indicates that the underlying system does not support the openprom device which is used to determine system configuration and hardware information Consequently the agent will attempt to determine the system s configuration without the operating system s help sent SIGKILL to process X On UNIX systems the SystemEDGE agent sent a KILL signal to a process whose PID is x This function is accomplished through SNMP Sets to the processKill variable in the Process Monitor table or to the hrRunStatus variable in the Host Resources hrSWRunTable sent signal X to process X eHealth SystemEDGE User Guide On UNIX systems the SystemEDGE agent sent a signal to a process whose PID is x This function is accomplished through SNMP Sets to the processKill variable in the Process Monitor table or to the hrRunStatus variable within the Host Resources hrSWRunTable Any valid UNIX signal can be sent to a process SystemEDGE Agent Error Messages 465 setLogmonEntry invalid set logfile row of status To set Log Monitor table rows that have a status of notInService you must perform SNMP Set operations made to those rows This error indicates that the Set operation it references failed setMonEntry bad size for OID val An SNMP Set operation to the Log Monitor table contained an incorrect length for a particular obj
434. send up to x consecutive monitorEvent traps and then send no more e 0x00500000 Contains the flag value x 5 for use with the directive above Removing Threshold Monitoring Entries 279 Monitoring the usr File System with edgemon The following example creates a Monitor table entry at index 20 to monitor the system s usr file system for a capacity that is greater than or equal to 95 checking the file system every 2 minutes 120 seconds edgemon 143 45 0 12 private filesystem usr devCapacity 20 0x00100500 120 absolute gt 95 Monitor usr Filesystem Removing Threshold Monitoring Entries To stop the threshold monitoring of a MIB variable you must remove the appropriate entry from the Monitor table This requires that you remove the entry from the both Monitor table and from the sysedge cf file As described in Dynamic Configuration During Operation on page 261 Monitor table entries are stored in the file sysedge mon to ensure that they are not lost when the SystemEDGE agent is restarted The monitor directives in the sysedge cf file create a monitor entry in sysedge mon whenever the SystemEDGE agent is started Removing Entries from the sysedge cf File If you configured a Monitor table entry by adding a monitor directive to the sysedge cf file you must delete it manually from sysedge cf If you do not remove the sysedge cf directive the entry will be recreated in sysedge mon the next time the SystemEDGE age
435. sion variable can be only read or read or written The agent will ignore the offending extension statement and will parse the remainder of the configuration file For more information about extending the SystemEDGE agent refer to Chapter 16 Adding Custom MIB Objects SystemEDGE Agent Error Messages 455 invalid extension variable type X The extension statement in the SystemEDGE agent configuration file contained an invalid SNMP type Valid extension variable SNMP types include the following integer counter gauge octetstring timeticks objectid and ipaddress The agent will ignore the offending extension statement and will parse the remainder of the configuration file For more information about extending the SystemEDGE agent refer to Chapter 16 Adding Custom MIB Objects invalid history description An emphistory configuration file statement contained an invalid description field Verify that the description is delineated by single quotation marks The agent will not create a history table entry and will ignore the statement The agent will however continue to parse the remainder of the configuration file invalid history object type An emphistory configuration file statement contained an object identifier whose base SNMP type is not an integer counter or gauge The SystemEDGE agent will not create a history table entry and will ignore the statement The agent will however continue to parse the remainder o
436. son expression that the agent uses is the following current value operator value Valid values for operator are described in Table 30 on page 247 Choose an appropriate value for comparison To help select an appropriate value you can monitor the particular object for a period of time to see what a normal value is The choice of this value 1s critical and depends on the semantics of the object you are monitoring If you want to receive monitorClear traps make sure you set the appropriate bit in the monFlags column Choose a monitor interval in seconds The interval must be a multiple of 30 seconds Choose the interval carefully For example you do not want the agent to sample so frequently that an operator cannot act on the condition that is being monitored if an exception occurs Choose the monitor options and specify the appropriate flags For more information refer to Monitor Table Flags on page 252 Add the entry to the sysedge cf file and then start the agent Adding Entries with the monitor Directive 261 Dynamic Configuration During Operation The SystemEDGE agent uses the You can dynamically modify entries in the Monitor table by SNMPv2 SMI textual convention sending SNMP Set request messages from your NMS including for creating deleting and AdvantEDGE View to the SystemEDGE agent Each time an modify ing rows in the SNMP request successfully modifies the Monitor table the Sey OU Oe AO S E O
437. specifies the object instance within the agent s MIB whose value should be sampled The OID can be specified using the complete dotted decimal value for example 1 3 6 1 2 1 25 1 5 0 or the symbolic MIB name for example hrSystemNumUsers 0 In both cases you must specify the object instance which is normally zero for non tabular MIB variables buckets Integer number that specifies the number of buckets or samples that the agent will store internally The agent stores the last buckets number of samples As the agent takes each new sample it deletes the oldest sample description Quoted string 0 to 128 characters in length that indicates the description field for this entry emphistory Command Example The following entry instructs the agent to sample the value of the object MemInUse through table index 15 every 120 seconds and to store the last 60 samples emphistory 15 120 memInUse 0 60 MemInUse history Dynamic Configuration During Operation You can use the emphistory command line utility to configure entries in the History Control table and to retrieve data samples from the History table dynamically The emphistory utility is located in the bin subdirectory of the SystemEDGE agent distribution You can also add history table entries to the agent configuration file manually For more information refer to the previous section Initial Configuration During Start Up on page 385 eHealth SystemEDGE User Guide C
438. ss ID of the process to monitor pmonCurrentPID Process ID PID of the current process being monitored If you are monitoring a Windows service through the watch ntservice directive or by setting flag 0x8000 this column represents the index in the NT Service MIB table that this process or service monitoring entry has acquired For more information about traps sent by the SystemEDGE agent refer to Chapter 8 Private Enterprise Traps eHealth SystemEDGE User Guide 298 e Chapter 11 Configuring Process and Service Monitoring Viewing the Process Monitor Table with AdvantEDGE View If you are using AdvantEDGE View you can query a system for Process Monitor table information by selecting the system you want to monitor from the System list selecting Process Monitoring from the Configuration list and clicking the Configuration icon For more information refer to the AdvantEDGE View Web Help Figure 45 shows a sample AdvantEDGE View Process Monitor table C Last Last MIOTA Monitor ypbind a absolute M invalid a 2 eaS 0 00 00 0x1 a pr i group WANI A Monitor ae notRunnable 49 days 1000 absolute gt linvalid 4 P rae c o 00 00 woo no action inete 150 OUR Poc EST 49 days no 5000 monitor absolute Pi invalid 4 Weegee 0 0 00 00 0x100 phe inetd inetd Add Process Monitor Entry Figure 45 Sample AdvantEDGE View Process Monitor Table Assigning Entry Rows for the
439. st System 1 at the following prompt Enter system description followed by newline 7 Press Return at the following prompt if you want to enter a location for your system Configure system location yes a Enter the system location for example QA Lab at the following prompt Enter system location followed by newline 8 Press Return at the following prompt if you want to enter the name of a contact for this system Configure system contact yes eHealth SystemEDGE User Guide Installing SystemEDGE on Solaris Systems 55 a Enter the contact name for example Test system contact and then press Return at the following prompt Enter system contact followed by newline Press Return at the following prompt to configure SystemEDGE to load the Top Processes AIM Enable Top Processes AIM yes The installation script displays the following Configuring community strings You should configure a read only and a read write community You need a read only community to discover SystemEDGE You need a read write community to use auto magic license utilities like licenseme AdvantEDGE View etc 10 Enter read only 11 Press Return at the following prompt to configure a read only community Configure a read only community string yes a Enter the name of the community that you want to configure as read only at the following prompt community no spaces case sensitive public The scr
440. stemEDGE agent does not perform error checking to determine whether you have specified an address that is valid for the specific system you are using as the trap source To specify a trap source add a line in one of the following formats to the sysedge cf file to specify the source of the trap e trap_source ip address e trap_source hostname For example to set the trap source to a system with an IP address of 10 0 7 73 and a hostname of system1 empire com you can do either of the following To use the IP address add the following line to sysedge cf trap_source 10 0 7 73 eHealth SystemEDGE User Guide 132 e Chapter 4 Configuring the SystemEDGE Agent To use the hostname add the following line to sysedge cf trap_source systeml empire com Configuring Authentication Failure Traps You can configure the SystemEDGE agent to send an Authentication Failure trap whenever it receives an SNMP message whose community name does not match one of the communities recognized by the agent By default the agent does not send Authentication Failure traps no_authen_traps To configure the agent to send Authentication Failure traps comment out the no_authen_traps directive in sysedge cf by placing a pound sign character at the beginning of the line as follows no_authen_traps Configuring Support for Who Table Information eHealth SystemEDGE User Guide By default the SystemEDGE agent supports the Who Table which provides
441. stemEDGE installer will need to stop the Microsoft SNMP service including subagents if it is running This is in addition to starting the SystemEDGE service as part of the installation Is this permissable 18 After clicking Yes in the previous step the following dialog box appears C Concord SystemEDGE must be licensed For Full Functionality Would vou like bo obtain a license key now 19 Click Yes if you want to obtain a license The Select License Type dialog box appears eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 69 InstallShield Wizard Select License Type Please indicate the license type Valid types are evaluation permanent usage or partner Most users Who have purchased SystemEDGE should select permanent An evaluation license is walid only for a limited time InstallShield 20 Specify the type of license evaluation permanent or usage based in the Type field and then click Next The following dialog box appears 21 Click Yes ifyou are using a Web server Ifyou do the Proxy Information dialog box appears a Enter the correct information in the Server Username and Password fields eHealth SystemEDGE User Guide 70 e Chapter 2 Installing the SystemEDGE Agent b Click Next If you click No the Web Licensing Account Information dialog box appears InstallShield Wizard Web Licensing Account Information Please enter your web
442. system poll the History table You can use SystemEDGE for short term history collection and eHealth or another management system for the long term historical view For more information refer to Chapter 15 Configuring History Collection Push the monitoring out to the agent and configure the agent to send traps based on these self monitoring entries Limit the number of potential traps from a single monitoring entry by using the following SystemEDGE flags as you set up your self monitoring entries x00000200 Send traps only after x occurrences of this event x00000400 Send up to x traps for this entry For more information about traps refer to Monitor Table Flags on page 252 Simple Network Management Protocol 47 For more usage tips refer to the following sections in this guide e Recommendations for Configuring Security on page 146 e Recommendations for Process and Service Monitoring on page 317 e Recommendations for Log File Monitoring on page 351 e Recommendations for Using Extensions on page 401 In addition refer to the SystemEDGE Contributions page at http www concord com sysedge contrib Simple Network Management Protocol SNMP is a standard for managing TCP IP based networks and devices A typical network management environment contains many managed devices each with an agent process and at least one NMS also referred to as the Manager or manag
443. t Yes Licenseme utility Yes Yes AdvantEDGE View Host Administration AdvantEDGE View Event Processing AdvantEDGE View Agent Deployment eHealth Yes TrapEXPLODER Yes Yes 1 The system from which the licensing tool is running does require Internet access but the target system does not 2 Use a scheduler daemon like cron to run the licenseutil pl script and license systems on your network automatically eHealth SystemEDGE User Guide 108 e Chapter 3 Licensing the SystemEDGE Agent Obtaining a License Key The SystemEDGE agent installation provides the option for you to license the agent automatically through the licenseme utility If you did not license the agent during the installation process you can obtain a license key manually as described in the following section To obtain a license key 1 Start the agent by entering one of the following commands from the sysedge directory at the command prompt For UNIX systems enter the following bin sysedge For Windows systems enter the following setup l NOTE You must be logged in as root or an administrator to start the agent The agent initially starts in unlicensed restricted mode The setup program displays a message similar to the following SystemEDGE Version 4 2 Patch level 1 Copyright 2004 by Concord Communications inc Could not find a valid license for machine pluto htto license concord com Provide the following sysedge pl
444. t less than gt greater than or equal to lt less than or equal to not equal monValue Integer value threshold to which the current value of the monitored MIB variable is compared monDescr Quoted string that is 0 to 128 characters in length and that normally contains a description of the object that is being monitored as well as a severity level monAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the expression evaluates to True and a trap is sent If the string is empty the agent performs no action for this entry Note The SystemEDGE agent logs action command invocations at syslog level LOG_DEBUG and action command invocation errors at syslog level LOG_WARNING For more information about configuring syslog refer to Appendix B For more information about starting the agent with its debugging options turned on refer to Configuring Support for Agent Debugging on page 135 eHealth SystemEDGE User Guide 264 e Chapter 10 Configuring Threshold Monitoring Threshold Monitoring Examples This section provides sample entries for the Monitor table to monitor thresholds on the target system Each example shows how to define the entry and describes the condition that is being monitored You can add these entries to sysedge cf Monitoring the 1 Minute Load Average The following examples configur
445. t specifies the full path of the command along with any parameters to be executed when the expression evaluates to True and the agent sends a trap If the string is empty no action will be performed for this entry By default no action is performed pmonRegExpr Read Write Specifies the regular expression to apply when the agent is attempting to acquire the process ID of an application or a process to monitor For Windows service monitoring this regular expression is used to match the name of the Windows service to monitor Rather than requiring users to specify process IDs PIDs or service indexes which may change users specify a regular expression for process name or service name The agent uses this user specified name to find the process to monitor By default the Process Monitor table keeps attempting to apply the regular expression until a new PID or service is found if the process or service stops running pmonMinValue Read Only Lowest minimum value that the agent has observed since it began polling the process attribute The default is 0 eHealth SystemEDGE User Guide The Process Monitor Table 287 Table 37 Columns of the Process Monitor Table Page 4 of 4 a pemes Only Highest maximum value that the agent has observed since it began polling the process attribute The default is 0 pmonCurrentPID Read Write PID of the process attribute pair that is currently being monitored pmonRowStatus Read Write One of the
446. t Log for invalid logins Checking Log File Status eHealth SystemEDGE User Guide When the SystemEDGE agent starts or after the addition of rows to the NT Event Monitor table it checks the status of stats each Windows event log for its current length and the time that it was last updated Thereafter the SystemEDGE agent periodically stats each event log for additions or modifications since the last update If the event log file has changed the agent scans only the changes not the entire event log to see if a match exists for the specified filters If the agent finds a match it sends an enterprise specific SNMP ntEventMonMatch trap message to the configured management systems For more information about the ntEventMonMatch trap refer to ntEventMonMatch Trap on page 224 Search Criteria Monitoring Windows Event Logs 359 Each Windows Event Monitor table entry instructs the agent to search for matches based on the criteria that are described in Table 62 Table 62 Criteria for Windows Event Log Searches Event Type Event Description Name of the event log This value can be any of the following e Application System Security DirService for Directory Service DnsServer for DNS Service FileRepService for File Replication Service Type of event Types 1 through 5 are defined by Windows as the following error 1 e warning 2 information 3 success 4 failure 5 Type all 6 indicates that the age
447. t table index 5 to the agent s History Control table This control entry instructs the agent to sample the ifInOctets 1 MIB object instance every 60 seconds and to store the most recent 10 samples emphistory add 127 0 0 1 private 5 ifInOctets 1 60 10 Deleting a History Control Entry The following entry deletes the History Control table entry at table index 3 emphistory delete 127 0 0 1 private 3 NOTE This entry also instructs the agent to delete the stored data samples in the History table that correspond to this control entry Setting the Row Status of a Control Entry The following example disables the control entry in the History Control table at table index 5 but it saves the corresponding stored samples in History table emphistory setstatus 127 0 0 1 private 5 2 The value 2 corresponds to the RowStatus textual convention value notInService 2 eHealth SystemEDGE User Guide 390 e Chapter 15 Configuring History Collection eHealth SystemEDGE User Guide Retrieving Stored Data Samples The following example retrieves all the stored data samples that correspond to the data collection function defined in row 5 of the History Control table emphistory dump 127 0 0 1 public 5 The following example retrieves all the stored samples for all control entries that is it retrieves the entire contents of the History table emphistory cumo 1247 001 public 1 Adding Custom MIB Objects The SystemEDGE agent pr
448. t the agent monitors for the given threshold You may choose any process attribute from Table 38 on page 288 The arguments for procAlive differ from those for the other attributes For more information refer to Using the watch process procAlive Directive on page 302 edgewatch Examples This section includes examples for using edgewatch Monitoring the ypbind Process The following example creates a Process Monitor table entry at index 16 to monitor the ypbind process that is running on the target system edgewatch 143 45 0 12 private process add procAlive ypbind 16 0x00 60 Monitor ypbind example pager sh The values in this example are defined as follows e procAlive is the process attribute being monitored It instructs the agent to monitor the process to make sure it is running ypbind is the process that the agent is monitoring It is responsible for client directory lookups and is necessary for machines running Network Information Services NIS e The flags field 0x00 instructs the agent to provide the default behavior for this table entry Ifthe process dies the agent sends a processStop trap and runs the action script example pager sh eHealth SystemEDGE User Guide 314 e Chapter 11 Configuring Process and Service Monitoring Monitoring the netscape Process The following example creates a Process Monitor table entry at index 20 to monitor the netscape process that is running on the target machin
449. t the request These parameters are passed after any parameters that you specified in quotation marks as part of the extension statement eHealth SystemEDGE User Guide Configuring Extension Variables 9395 Table 76 describes the additional parameters that can be passed to the extension command Table 76 Additional Parameters for the extension Command Request Type An integer value that represents the leaf number of this variable 1 through 2 If you have a single script that supports multiple extension values you can use this parameter to determine which variable is being requested A string that indicates the type of SNMP request e Get e GetNext e Set The request type is passed with all letters capitalized A string that contains the value that is passed in a Set request Use this string in your extension program to modify the current value of the variable in such a way that a future Get or GetNext can return this value eHealth SystemEDGE User Guide 396 Chapter 16 Adding Custom MIB Objects Extension Examples The SystemEDGE agent includes several sample extension variables These examples are defined in the sample sysedge cf file The scripts that implement these examples are included in the contrib subdirectory of the SystemEDGE agent distribution These variables are also defined in the Systems Management MIB empire asn1 in the doc subdirectory of the SystemEDGE agent distribution CAUTION
450. t was configured for this entry pgmonPIDList Read Only List of the numeric PIDs in this process group Each PID is separated from the next by a space character pgmonStatusList Read Only List of the process states in this process group Each process state is separated from the next with a space character Entries in the status list have a one to one correspondence with entries in the PID list For more information about states of a process refer to the processStateStr MIB variable pgmonAction Read Write Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the expression evaluates to True If the string is empty the agent invokes no action for this entry By default it invokes no action pgmonNumEvents Read Only Number of events for this entry Events do not necessarily imply traps traps can be turned off for the row through a flags setting pgmonNumTraps Read Only Number of traps that the agent has sent for this entry pgmonLastTrap Read Only Time based on sysUpTime at which the agent last sent a trap for this entry A value of 0 indicates that no traps have been sent eHealth SystemEDGE User Guide 322 Chapter 12 Configuring Process Group Monitoring Table 46 Columns of the Process Group Monitor Table Page 3 of 4 Column Name Permissions Description pgmonRowStatus Read Write One of the following active 1 notInService
451. tString Registry SYSTEM CUrrentControLlLSet Control CrashControl Dumprile The object instance identifier of this object is 1 3 6 1 4 1 546 5 7 1 0 eHealth SystemEDGE User Guide 410 e Chapter 17 Adding Windows Registry and Performance MIB Objects Objects Threads The following ntRegPerf object returns the total number of threads that are currently in the system ntregperf 2 Gauge Performance Objects Threads 1 The object instance identifier of this object is 1 3 6 1 4 1 546 5 7 2 0 TCP Segments Sent Sec The following ntRegPerf object returns the total number of TCP segments that were transmitted by the system ntregperf 3 Counter Performance TCP Segments Sent sec 1 The object instance identifier of this object is 1 3 6 1 4 1 546 5 7 3 0 Using Windows Registry and Performance Variables with Your Management Software There are several methods for incorporating ntRegPerf variables into your management system software for example Aprisma Spectrum HP OpenView Sun Enterprise Manager and so on all of which require editing and importing MIB specification files While the details of importing MIB specification files into management system software are beyond the scope of this guide two overall strategies exist for incorporating ntRegPerf variables e Edit empire asn1 to include the ntRegPerf variables that are defined for your site Edit a separate MIB file to include the ntRegPerf variables
452. table 366 overview 35 Process Group Monitor table 326 Process Monitor table 296 adding custom MIB objects 34 391 entries History Control table 389 511 Log Monitor table 348 506 Monitor table 494 NT Event Monitor table 508 Process Group Monitor table 329 Process Monitor table 499 503 performance registry variables 405 addrChangeTrap 228 AdvantEDGE View configuring History Control table 384 Log Monitor table 342 Monitor table 256 NT Event Monitor table 368 Process Monitor table 298 327 using with SystemEDGE 37 agent multiplexing 158 AIMs configuring support 143 enabling in sysedge cf 143 overview 39 See also eHealth application insight modules AIX installing SystemEDGE 82 platform support 23 removing SystemEDGE 102 029 530 e ndex SNMP agent 163 system requirements 82 asset tracking 34 assigning entry rows Monitor table 257 Process Group Monitor table 327 Process Monitor table 298 audience 24 authentication failure traps UNIX 132 auto install file 96 automating deployment of SystemEDGE agent configuring software for distributed systems 419 methods 417 security issues 420 installation 96 B bibliography 525 bin subdirectory all platforms 96 UNIX 90 Windows 92 Boot Configuration group Systems Management MIB 169 bounce exe 92 C call sendtrap c file 96 cffile txt 93 changing process nice value 175 checkfile exe 90 92 checkprinter exe 96 CIM SNMP agent 164 eHealth SystemEDGE User Guid
453. table stores the most recent buckets number of samples status Used with the setstatus operation this value specifies the RowStatus textual convention value to use in setting the status of a row in the History Control table The rowStatus parameter can be one of the following values e active 1 e notInService 2 e destroy 6 Setting the row status to destroy 6 causes the agent to discontinue history sampling for that entry and to delete the row in the History Control table and the corresponding data sample rows in the History table For more information about RowStatus textual convention refer to Appendix E descriprion Optional description You can specify a description when adding a row If you specify a value emphistory uses the supplied string instead of the default History Control entry description string If you include a description you must enclose it within single quotation marks The description must be less than 128 characters not including the quotation marks Longer strings are truncated eHealth SystemEDGE User Guide Configuring the History Control Table 389 emphistory Utility Examples This section provides examples for using the emphistory utility Listing Entries in the History Control Table The following example lists the contents of the agent s History Control table emphistory list 127 0 0 1 public Adding a History Control Entry The following example adds a new control entry a
454. tance of process monitoring and explains the attribute or threshold that is being monitored eHealth SystemEDGE User Guide Configuring the Process Monitor Table 307 Monitoring Sendmail to Make Sure It Is Running The following example configures the SystemEDGE agent to monitor the sendmail daemon on the underlying system watch process procAlive sendmail 11 0x00000100 60 Monitor sendmail The values in this example are defined as follows e 11 indicates that this entry will occupy row 11 pmonIndex 11 in the Process Monitor table The flags field value of 0x00000100 indicates that the agent should monitor the parent sendmail process if more than one sendmail daemon is present and running e 60 indicates that the agent should check the sendmail process every 60 seconds e No action is specified so the agent will not invoke a command when it sends a trap Monitoring the Simple TCP IP Services Process To Make Sure It Is Running The following example configures the SystemEDGE agent to monitor the TCPSVCS process that makes up the Simple TCP IP Services service watch process procAlive TCPSVCS 15 0x00000000 30 Monitor NT TCP services The values in this example are defined as follows e 15 indicates that this entry will occupy row 15 pmonIndex 15 in the Process Monitor table The flags field value of 0x00000000 indicates that the agent should provide the default process monitoring behavior e 30 i
455. te programs that are executing Almost all versions of UNIX include RDIST but most include a very old version sometimes referred to as 4 2BSD rdist rdist classic or rdist version 3 Network File System NFS NFS is a client server file sharing protocol that lets you view and optionally store and update files on a remote computer as though they were on your own computer To use NFS your system must have an NFS client and the other computer must have the NFS server Both systems must also have TCP UDP IP installed Microsoft Windows for Workgroups Windows 95 and Windows NT include client and server SMB protocol support Automating Deployment 419 Server Message Block Protocol SMB SMB provides a method for client applications on one computer to read and write to files on and to request services from server programs in a computer network You can use SMB over the Internet on top of its TCP IP protocol or on top of other network protocols such as IPX and NetBEUI Using the SMB protocol an application or the user of an application can access files at a remote server as well as other resources including printers mailslots and named pipe Thus a client application can read create and update files on the remote server It can also communicate with any server program that is set up to receive an SMB client request Installing Software on Remote Systems You can install software on remote systems in several ways Using
456. te the appropriate entry in the target agent s Monitor table Using the edgemon Utility to Monitor Thresholds 275 Use the edgemon utility as follows edgemon ipaddr port timeout commstr command Table 35 describes the parameters to the edgemon utility Table 35 edgemon Parameters ipaddr port timeout Specifies the hostname or IP address of the system on which the agent exists If the agent is running on an alternative UDP port for example 1691 you must specify that port number and the hostname or IP address through a colon separator In addition you can specify an optional SNMP timeout value in seconds using a command separator commstr Specifies the community string that edgemon uses in its SNMP requests to the agent Because edgemon uses SNMP Set requests use a community string that provides read write access to the target agent command Specifies the command and associated arguments Supported commands include the following oid for monitoring an object filesystem for monitoring a file system list for listing the current Monitor table entries setstatus for setting the status of an Monitor table entry delete for deleting a Monitor table entry For more information about these commands refer to the next section edgemon Commands for Threshold Monitoring eHealth SystemEDGE User Guide 276 e Chapter 10 Configuring Threshold Monitoring edgemon Commands for Threshold Monitoring Th
457. tem location and then press Return at the following prompt Enter system location followed by newline Press Return at the following prompt if you want to enter the name of a contact for this system Configure system contact yes a Enter the contact name for example Test system contact and then press Return at the following prompt Enter system contact followed by newline Press Return at the following prompt to configure SystemEDGE to load the Top Processes AIM Enable Top Processes AIM yes eHealth SystemEDGE User Guide 78 e Chapter 2 Installing the SystemEDGE Agent The installation script displays the following Enabling topprocs hpux32bit so AIM Configuring community strings o You should configure a read only and a read write community o You need a read only community to discover SystemEDGE o You need a read write community to use auto magic license utilities like licenseme Enter read only 11 12 AdvantEDGE View etc Press Return at the following prompt to configure a read only community Configure a read only community string yes a Enter the name of the community that you want to configure as read only at the following prompt community no spaces case sensitive public The script displays the following Setting read only community to public Press Return at the following prompt to configure a read write community Configure a read write community string y
458. temEDGE you can monitor process attributes for mission critical processes Windows services and applications For example you can monitor whether a process is running the network I O system calls and other attributes If any processes stop running SystemEDGE can automatically notify the NMS and restart them if necessary You can configure SystemEDGE to monitor processes in the Process Monitor table On Windows systems SystemEDGE can also monitor Windows services For more information refer to Chapter 11 Configuring Process and Service Monitoring Process Group Monitoring You can use the Process Group Monitor table to define a set of processes that the SystemEDGE agent can track SystemEDGE can track the number of processes by name and arguments that match the regular expression you specified It can also indicate when a process group changes through the processGroupChange trap In addition it can match processes by user name and group name For more information refer to Chapter 12 Configuring Process Group Monitoring Log File Monitoring SystemEDGE can monitor any ASCII based system or application log file for regular expressions For example you can configure the SystemEDGE agent to monitor the log file var adm sulog for a regular expression that you specify Whenever a message that matches the regular expression you specified is logged to the file SystemEDGE notifies the NMS through an SNMP trap and includes
459. temEDGE agent could not open the UNIX device dev kmem which allows the agent to read kernel memory Verify that dev kmem exists and that the agent has permission to read it Running the SystemEDGE agent as a user other than the root user could cause this problem cannot find title index for On Windows the SystemEDGE agent could not properly initialize the relevant information to read a particular performance variable from the Windows registry Only this variable is affected All other Windows variables should be supported cannot locate disk pstat data diskStatsTable not supported On HP UX systems the SystemEDGE agent was unable to locate the appropriate disk statistics through an HP UX application programmer interface API Disk statistics for the particular drive are therefore not supported Disk statistics for other drives however should be unaffected cant open kmem On UNIX systems the SystemEDGE agent reads the device kmem to retrieve certain kernel parameters and statistics This error message indicates that the agent could not open the dev kmem device perhaps due to permissions problems Verify that the agent has read access to dev kmem eHealth SystemEDGE User Guide 442 Appendix A Error Messages cant open socket for mib 2 On some UNIX systems the SystemEDGE agent uses a socket to obtain MIB II statistics This error message indicates that the agent was unable to obtain such a socket Most likely the a
460. temEDGE agent makes data about all file systems local and remote available through the Systems Management MIB However on some UNIX systems SystemEDGE can be blocked if a file system is mounted from a remote file server that is no longer available either if it is down or if the network connection between the server and client is down Unfortunately there is no way for the SystemEDGE agent to unblock in this situation To circumvent this blocking configure SystemEDGE agent to avoid checking status on remote file systems To do so add the following line to the sysedge cf file no_stat_nfs_ filesystems NOTE If you add this line to the sysedge cf file it disables the checking of all remote file systems not just NFS file systems Configuring Support for Threshold Monitoring eHealth SystemEDGE User Guide The SystemEDGE agent includes support for threshold monitoring of MIB objects including file systems interfaces processors and so on You can use SNMP Set requests to add entries for threshold monitoring dynamically while the agent is running or you can define them in the sysedge cf configuration file that the SystemEDGE agent reads when it starts For more information about creating entries in the Monitor table refer to Chapter 10 Configuring Threshold Monitoring Configuring Support for Process Monitoring 139 Configuring Support for Process Monitoring By default the SystemEDGE agent allows SNMP Gets and S
461. terday From 04 23 2002 12 00 AM To 04 23 2002 11 59 PM NT System Disk I O reads amp writes sec 18 0 Simm ae a a a ar ame 15 5 pE se oc aa a gv J HB Reeds E Writes Disk I O Busy Utilization 16 Disk I O Queue Length reads amp writes 1 0 6 E ooo aN A a a Disk Errors errors sec 1 0 6 0 2 _ 0 A User Partition Space Used bytes Capacty I Used Total Network I O frames sec Total Network Errors errors sec TE rr 8 J n E rr E E E System Latency msec 1 0 6 iis 1 s s as N ka Created 04 24 2002 01 00 41 AM Figure 2 Sample AAG Report for Systems eHealth SystemEDGE User Guide 42 e Chapter 1 Introduction Using eHealth Live Health Fault Manager with eHealth SystemEDGE eHealth SystemEDGE User Guide You can also use the SystemEDGE agent with Live Health Fault Manager for real time detection of potential problems Live Health extends the features of eHealth to provide real time performance and availability management for applications systems and networks The SystemEDGE agent collects performance data and Live Health analyzes the data with unique algorithms to identify outages and delays When you are using the SystemEDGE agent with Live Health you can use the default Live Exceptions profiles for the SystemEDGE agent and the eHealth AIMs or you can define your own profiles The profiles organize alarm variables by delay
462. ternal error please report An internal SNMP library error has occurred within the program Report this message to Technical Support by sending an e mail to support concord ca com sysvariable WSAStartup failed On Windows systems sysvariable was unable to initialize the WinSock library and could not communicate with the targeted SystemEDGE agent The requested action therefore was not performed walktree Error Messages This section describes error messages that may be generated by the walktree utility cant resolve address for The address or hostname that was provided to walktree could not be resolved to a valid IP address so the requested action was not performed Verify that the hostname has a valid address through tools like host or nslookup ERROR could not create output file walktree could not open the specified output file due to an error opening or creating it No walk operation was performed walktree internal error please report An internal SNMP library error has occurred within the program Report this error to Technical Support by sending an e mail to support concord ca com eHealth SystemEDGE User Guide 486 e Appendix A Error Messages walktree retries should be at least 1 walktree attempts to retry failed SNMP requests because SNMP packets may be dropped or lost This error message indicates that the retry value that was specified on the command line was invalid walktree WSAStartup failed
463. that you can send to Technical Support 1 Change to the sysedge bin directory 2 Enter the following diagsysedge exe The command creates a diagsysedge txt file that provides information similar to the following e Version of the diagsysedge exe program e Current date and time eHealth SystemEDGE User Guide Common Problems and Questions 425 IP address of the system on which you are running the agent e Operating system platform e Community string e Port on which the agent is running Timeout value Location of the sysedgediag txt output file e Contents of the sysedge cf sysedge lic and sysedge mon files from the etc UNIX or SystemRoot System32 directory Windows Information about registry settings that the setup program modified A detailed System Information report If the agent is not running you receive an error message that the SNMP operation failed Attempt to start the agent again using the instructions in this chapter for your operating system Common Problems and Questions This section describes problems that might occur when you are installing and using the SystemEDGE agent It also provides instructions for resolving these problems This section is organized by observable symptoms of a problem and questions for each symptom to help you isolate the cause Agent Not Responding to SNMP Requests When the agent is not responding to SNMP requests the NMS software cann
464. the table lists the following e Unique identifier Software package s name e Description e Installation date This table allows you to see operating system patches and versions of software that have been installed It is ideal for checking software version consistency between systems Figure 29 shows part of an hrSWInstalledTable for a Solaris 2 x system Unsupported MIB Objects on Windows Systems 243 e SNMP Table Display Tablet hrSWInstalledTable Path 1 3 6 1 2 1 25 6 3 1 Rowst10 Columns 5 hrShInstal ledName hrShInstal led ID hrShInstal ledType fkernel unixt SunOS 5 3 Generic_Patch null operatingSystem 2 gt SUNWkymCore Architecture Kvm 311 5 0 REV 2 0 18 null operatingSystem 2 SUNWcsuzCore Sparc Usr 211 5 0 REV 2 0 18 null operatingSystem 2 SUNWesr Core Sparc Root 11 5 0 REV 2 0 19 null operatingSystem 2 gt SUNWesd Core Sparc Devicest11 5 0 REV 2 0 18 null operatingSystem 2 SUNWearsCore Architecture Root 11 5 0 REV 2 0 18 null operatingSystem 2 SUNWesutExtended System Utilitiest11 5 0 REV 2 0 18 null operatingSystem 2 gt SUNWtltksToolTalk runtime 3 3 18 REV 0 93 09 07 null operatingSystem 2 gt SUNWaudiotAudio applicationst3 0 REV 1 1 1 null operatingSystem 2 SUNMxilow XIL Deskset Loadable Pipeline Libraries 1 1 REV 2 0 0 null application 4 OK ert Fae Figure 29 Sample Host Resources Installed Software Table NOTE Not all systems can support this table To determine whether it i
465. the Monitor table Table 33 describes the default parameters for Monitor table actions eHealth SystemEDGE User Guide 256 e Chapter 10 Configuring Threshold Monitoring Table 33 Default Parameters for Monitor Table Actions trapType Type of trap that is being sent For example monitorEvent or monitorEntryNotReadyEvent Description from this table entry Object Identifier from this table entry Current value from this table entry Value that is being monitored from this table entry monRowStatus Current row status for this table entry monOperator Operator that is being used from this table entry The value passed to the action script is the numeric representation of the actual operator For example if the operator is gt the value passed to the action script is 2 Index from this table entry monFlags Flags that are associated with this table entry The value passed to the action script is in base 16 hexadecimal notation with a leading Ox to indicate that it is a hexadecimal number for example 0x00000020 Viewing the Monitor Table with AdvantEDGE View If you are using AdvantEDGE View you can query a system for Monitor table information by selecting the system you want to monitor from the System list selecting Self Monitoring from the Configuration list and then clicking the Configuration icon For more information refer to the AdvantEDGE View Web Help Figure 34 shows a sample AdvantEDGE View Monitor tabl
466. the SystemEDGE agent returned another type Verify that the object identifier that was passed to snmpget is correct SNMP Get failed snmpget failed to get one of the request variables due to an error in the SNMP Get operation Verify that the community string and target IP address or system name are correct The request may or may not have succeeded snmpget WSAStartup failed On Windows systems snmpget was unable to initialize the WinSock library and could not communicate with the targeted SystemEDGE agent The requested action therefore was not performed sysvariable Error Messages eHealth SystemEDGE User Guide This section describes error messages that may be generated by the sysvariable utility cant resolve address for The address or hostname that was provided to sysvariable could not be resolved to a valid IP address so the requested action was not performed Verify that the hostname has a valid address through tools like host or nslookup GET failed sysvariable failed to get one of the request variables due to an error in the SNMP Get operation Verify that the community string is valid and that the target system hostname or IP address are correct Command line Utility Error Messages 485 SNMP Operation failed sysvariable failed to get one of the request variables due to an error in the SNMP operation Verify that the community string and target hostname or IP address are correct sysvariable in
467. the SystemEDGE agent to monitor the 1 minute load average on the target system Index Description Interval SampType ObjID CurrVal Oper Value LastCall Traps LastTrap RowStatus Action Flags 12 Imin load avg 60 absoluteValue loadAvg1Min 0 1 gt 300 Od 22 40 00 0 0 active a 0x0 This entry provides the following information e This is the twelfth row in the table Its purpose is to monitor the system s 1 minute load average Every 60 seconds the agent checks the absolute value of the loadAvglMin MIB variable whose current value is 1 to see if it is greater than 300 the specified threshold value If it is the agent sends a trap to any configured NMS and updates the NumTraps and LastTrap columns appropriately eHealth SystemEDGE User Guide The Monitor Table 247 e With each poll the agent updates the CurrVal column with the value it has just retrieved records the time in the LastCall column and updates the MinValue and MaxValue columns if appropriate that is if the value just polled is the lowest or highest value observed thus far The RowStatus column shows that this entry is active In this example the action is null so no command will be executed when the trap is sent The Flags column is set to zero which indicates the default Monitor table behavior For more information about flags for the Monitor table refer to Monitor Table Flags on page 252 Columns of the Monitor Table Table 30 def
468. thin a reserved block of rows without being concerned that the row might already be taken by another user s entry In compliance with the local policy all other users should use row indices that are outside the reserved range when they define user configured entries eHealth SystemEDGE User Guide 258 e Chapter 10 Configuring Threshold Monitoring Reserving Blocks of Rows You can also use this row number assignment policy with AdvantEDGE View for group configuration operations By reserving a block of rows you can define a consistent set of conditions row entries to be monitored across all machines such that the same condition is defined in the same row number on each machine For example you can use row 11 monIndex 11 to define an entry for monitoring the swapCapacity variable and you can then distribute this configuration to every system so that row 11 is used to monitor the swapCapacity variable on every system To reserve a block of rows for threshold monitoring 1 Decide which block of rows you want to reserve for use 2 Use that block of rows to define a set of row entries conditions to be monitored in the sysedge cf initialization configuration file For more information refer to Configuring the Monitor Table on page 258 3 Distribute the sysedge cf file to all systems on which the SystemEDGE agent is installed 4 Require users to avoid your block of rows when they define their own Monitor table
469. tializing Non defaulted Objects eHealth SystemEDGE User Guide The management station must now determine the column requirements It issues a management protocol get operation to examine all columns in the created conceptual row In the response for each column there are three possible outcomes e A value is returned indicating that the agent implements the object type associated with this column and had sufficient information to provide a value For those columns to which the agent provides read create access a value return tells the management station that it may issue additional management protocol set operations if it desires in order to change the value associated with this column e The exception noSuchInstance is returned indicating that the agent implements the object type associated with this column and that this column in at least one conceptual row would be accessible in the MIB view used by the retrieval were it to exist However the agent does not have sufficient information to provide a value and until a value is provided the conceptual row may not be made available for use by the managed device For those columns to which the agent provides read create access the noSuchInstance exception tells the management station that it must issue additional management protocol set operations in order to provide a value associated with this column Conceptual Row Creation 521 e The exception noSuchObject is returned ind
470. timer event X cece eee eee eee 447 failed to create a trap SESSION 6 eee eee eee 447 failed to create timer event cece eee eee eee 447 failed to create trap pdU cece eee eee eens 447 failed to get dkscinfo 4 s0cacaddacadwatwiesaracvina ded 448 failed to get domain name cee eee ee eee 448 failed to get service handle 0 ce eee ee ee eee 448 failed to open dev netman 0 cece eee ee eens 448 failed to open systeM a5 nose cdecAcenneue cae seers 448 failed to open var adm sw products 0 0008 449 failed to open var sadm patch 0 cee ee eee eee 449 failed to open var sadm pkg 0 cece eee eee 449 failed to open config file X 1 eee cee ee eee 450 failed to Open 1OCONMIG 2 656 eseebieesaavecsderavesss 450 failed to open ip for mib2 cece eee eee 450 failed to Open kKMe M s 02444044 esse cowed sens seam eeees 450 failed to open mnttab file 0 eee eee 450 failed to open create mon file 0 0 cece cece eee 451 failed to open openprom device 0 cece cee ee ees 451 failed to parse config ING w 5chexncernciecaronedenh wade 451 failed to push ARP for mib2 0 0 cee eee eee ee 451 failed to push TCP for miD 4 2 s4ec0en1esaredenteews 452 failed to push UDP for mib2 0 0 00 eee eee 452 failed to read ioconfig Magic kee eee ee eee 452 failed to read monitor file 0 eee eee eee 4
471. tion configuration file directives in sysedge cf take precedence over those in sysedge mon eHealth SystemEDGE User Guide 434 e Chapter 19 Troubleshooting and Usage Suggestions To update the SystemEDGE agent s monitor configuration file 1 Open a command prompt 2 Stop the agent On Windows enter the following net stop sysedge e On Solaris enter the following when you are logged in as root etc rc2 d S99sysedge stop NOTE For other UNIX operating systems enter the path and name for your SystemEDGE startup script For a list of startup script names refer to SystemEDGE Directories and Files for UNIX Systems on page 90 3 Use a text editor to update sysedge mon 4 Restart the agent On Windows enter the following net start sysedge e On Solaris enter the following when you are logged in as root etc rc2 d S99sysedge start NOTE For other UNIX operating systems enter the path and name for your SystemEDGE startup script For a list of startup script names refer to SystemEDGE Directories and Files for UNIX Systems on page 90 eHealth SystemEDGE User Guide Common Problems and Questions 435 5 Verify that the updated sysedge mon file does not contain any errors To do so examine the sysedge log file on Windows or the syslog file output on UNIX for error messages pertaining to the monitor configuration file NOTE You can update the sysedge mon file directly but you should not
472. tion starting This script enables you to configure the SystemEDGE agent You can change the configuration information after the installation if desired for more information refer to Chapter 4 Configuring the SystemEDGE Agent The installation script also enables automatic licensing of the agent For information about additional ways to license the agent refer to Chapter 3 Licensing the SystemEDGE c gt Agent eHealth SystemEDGE User Guide 86 e Chapter 2 Installing the SystemEDGE Agent NOTE For a detailed example of the installation script refer to Installing SystemEDGE on HP UX Systems on page 75 For each prompt the default value is shown in brackets You can press Return to accept the default or you can enter another value and then press Return Reviewing the Configuration Files eHealth SystemEDGE User Guide When the SystemEDGE agent first starts it reads the following configuration text files to determine configuration settings and to check that the system has a valid license key for running the agent e sysedge lic e sysedge cf e sysedge mon The SystemEDGE agent installation automatically installs these files in the etc UNIX or SystemRoot system32 Windows directories during the installation process unless you are upgrading from a previous version of the SystemEDGE agent If you are upgrading SystemEDGE does not overwrite your existing files but copies the new files to the
473. tions This limitation means that the person creating or modifying History Control table entries through the emphistory command or by editing sysedge mon must know the exact MIB table index to use for row creation empireHistoryControlDescr Text string that describes the data collection function defined by this entry and that may include who created it empireHistoryControlBuckets Total number of samples to be stored for this variable emphistoryControlObjID Complete object instance identifier of the MIB variable to be sampled Note that you must include the instance portion of the object identifier for example 0 for scalars The object instance must exist and must be contained within the Systems Management MIB For example any supported integer based object in MIB II the Host Resources MIB or the Systems Management MIB is valid Objects should be of integer type including counter gauge integer or enumerated integer empHistoryControllInterval Integer value indicating how often in seconds to sample the MIB variable The interval must be a multiple of 30 seconds eHealth SystemEDGE User Guide 912 e Appendix C Adding Self Monitoring Entries to the sysedge mon File Table 91 Columns of the History Control Table Page 2 of 2 Column Name Description empHistoryControlStatus One of the following e active e notInService notReady e createAndGo createAndWait These values are identical in meaning to the SNMPv2 SMI Row
474. tiple SNMP agents agent multiplexing 158 AIX SNMP agent 163 CIM SNMP agent 164 Digital UNIX SNMP agent 163 HP UX SNMP agent 162 Microsoft Windows Extensible agent 161 monolithic agents 159 overview 157 Solstice Enterprise Agent 160 Tru64 SNMP agent 163 sysedge file 90 script 95 sysedge 1 man page 91 sysedge cf directory 94 sample file 119 sysedge cf 5 man page 91 sysedge cpl 92 sysedge dll 92 sysedge exe 92 sysedge lic 86 directory 94 sample file 106 sysedge mon file adding entries History Control table 511 Log Monitor table 506 Monitor table 494 NT Event Monitor table 508 Process Monitor table 499 503 backing store 493 examples eHealth SystemEDGE User Guide 042 e Jndex collecting disk transfer history 512 monitoring l minute load average 497 monitoring httpd process 505 monitoring log files 507 monitoring netscape process 502 monitoring size of netscape process 502 monitoring Windows event log files 510 fields History Control table 511 Log Monitor table 506 Monitor table 495 NT Event Monitor table 508 Process Monitor table 499 503 format 493 history keyword 511 installation directory 86 location 86 logmon keyword 506 monitor keyword 494 nteventmon keyword 508 processmon keyword 499 procgroupmon keyword 503 sample entries History Control table 512 Log Monitor table 507 Monitor table 497 NT Event Monitor table 510 Process Group Monitor table 505 Process Monitor table 501 updating 433 sysedge mo
475. tistic structure of the kernel Consequently disk statistics may not be supported discovering HPUX devices by hand On HP UX systems the SystemEDGE agent is discovering devices manually rather than through automated techniques This discovery method is used on older versions of HP UX which do not support those automated methods empire_agent_init failed On Windows systems the SystemEDGE agent failed to initialize due to licensing errors invalid or non existent configuration files or some other problem The SystemEDGE agent will normally print additional more specific error messages that indicate the cause of the problem error parsing X in monitor file line Y The SystemEDGE agent encountered an error while parsing the sysedge mon monitor configuration file It prints the offending line number event regcomp failed X desc_filt The SystemEDGE agent failed to compile a Windows event monitoring regular expression because it was invalid Verify the regular expression and try the management operation again eHealth SystemEDGE User Guide SystemEDGE Agent Error Messages 445 executing subprograms as group X On UNIX systems the SystemEDGE agent is executing all subprograms with permissions of group x as specified in a configuration file directive executing subprograms as user Y On UNIX systems the SystemEDGE agent is executing all subprograms with permissions of user Y as specified in a configuration file
476. tmib asn1 Host Resources MIB specification RFC 1514 This document describes the meaning and use of all of the management objects in the Host Resources MIB PDF copy of the eHealth SystemEDGE User Guide PDF copy of the eHealth SystemEDGE Release Notes NOTE The SystemEDGE agent installation script enables you to install SystemEDGE as your default SNMP agent to configure SystemEDGE to start up by default when the system is booting to turn off your native SNMP agent and to make changes to the startup rcX d files If you did not configure the agent to start automatically during the installation you can change those settings manually eHealth SystemEDGE User Guide Uninstalling the SystemEDGE Agent This section explains how to remove the files and subdirectories that are associated with the SystemEDGE agent NOTE The following steps also remove the agent s license file sysedge lic configuration file sysedge cf and Monitor table configuration file sysedge mon from the etc UNIX or SystemRoot system32 Windows directory If you want to save these files copy them to another directory before you run the Remove utility Uninstalling SystemEDGE for Solaris Systems Use the Solaris package remove utility pkgrm to remove the SystemEDGE agent package EMPsysedg from your system 1 Run the pkgrm utility by entering the following command pkgrm EMPsysedg 2 Answer y yes to the prompts Uninstalling System
477. tor any integer based MIB variable under its control You can specify the variable to monitor the polling interval a comparison operator greater than equal to and so on anda threshold value The SystemEDGE agent automatically monitors that variable and sends a trap to the management system if the condition you specified is met For more information about traps sent by the SystemEDGE agent refer to Chapter 8 Private Enterprise Traps The agent can also invoke a command on the managed system to perform management functions to correct whatever caused the exception immediately For example you can configure the SystemEDGE agent to monitor the percent capacity for the root file system and to notify the manager if it becomes too full 245 246 e Chapter 10 Configuring Threshold Monitoring The Monitor Table The Monitor table which is located in the Systems Management MIB empire asn1 provides information about each condition that the agent is currently monitoring Each row represents a single condition that the agent is monitoring For each entry the table provides the following types of information e Variable that the agent is monitoring e Interval at which the agent checks the variable e Current value e Conditions that will cause the agent to send a trap e Number of traps that have been sent already Sample Entry in the Monitor Table This section provides an example of an entry in the Monitor table that instructs
478. toring File System Space The devCapacity column which shows the percentage of file system space being used is ideal for checking for file systems that are in danger of becoming too full You can use the Monitor table to instruct the agent to monitor the devCapacity values for you and to send a trap to the management system if the value goes above the threshold value that you select For example you can have the agent monitor the usr directory and send a trap if it becomes greater than 90 full For more information about setting thresholds refer to Chapter 10 Configuring Threshold Monitoring Unmounting a Mounted Device When you are unmounting devices use a community name that allows you read write access You can unmount a mounted device by setting the devUnmount column for that device to the value delete 1 When you do so the agent unmounts the device and removes its entry from the Mounted Devices table Kernel Configuration eHealth SystemEDGE User Guide You can identify the version of the kernel that is running on the system and determine how the kernel is configured by retrieving objects in the Kernel Configuration group Kernel configuration parameters include the following e Maximum number of processes that can run concurrently e Number of CPUs e Clock rate e Amount of virtual memory e Maximum number of inodes open files and clists e Amount of system swap space e Maximum memory and open files allowed
479. tribute for each event in the log You must enclose this value in quotation marks eHealth SystemEDGE User Guide Using the edgewatch Utility to Monitor Windows Events 375 Table 69 Parameters of the ntevent Commands Page 2 of 2 ate vente Monvescr iI Regular expression to apply when scanning the Event Description attribute for each event in the log You must enclose this value in quotation marks ntEventMonDescr Quoted string that is 0 to 128 characters in length and that normally contains a description of the file that is being monitored as well as a severity level for this event ntEventMonAction Quoted string that is 0 to 256 characters in length and that specifies the full path of the command along with any parameters to be executed when the entry is matched and a trap is sent If the string is empty or not specified no action will be taken RowStatus Used with the setstatus operation this value specifies the RowStatus textual convention value to use in setting the status of a row in the NT Event Monitor table The RowStatus parameter is an integer that can take on one of the following values active 1 notInService 2 notReady 3 destroy 6 For more information about the RowStatus convention refer to Appendix E Sample Uses of edgewatch for Monitoring Windows Events This section provides examples for using the edgewatch utility to monitor Windows events Listing Entries in the
480. turn unknown 1 when queried for a serialport status if the command below is uncommented the default is to support serial port status queries no_ serial _ status Tell the agent not to query the status of floppy drives no_stat_floppy eHealth SystemEDGE User Guide 120 e Chapter 4 Configuring the SystemEDGE Agent E HH HAHHA HHH EHEHEHEH o E HHEH HEHHEHE HHHH HEH H H Tell the agent not to allow SNMP Sets in the Empire process or HostMIB runningSoftware tables The default is to allow SNMP Sets to those tables given a valid community string supporting read write access Allowing Sets to these two tables allows remote managers to send processes signals and kill them if desired NnoO_process sets Tell the agent not to support Actions The default is to invoke Actions when a monitor log monitor or event monitor table entry evaluates to True Actions are executed as the root so care must be taken as to which Action scripts are invoked no_actions Tell the agent not to support the Installed Software table of the Host Resources MIB This token is currently valid only on Linux systems no_hrswinstalled You can extend the Empire Enterprise MIB by adding new scalar variables Each entry here represents a new leaf in the Extension group of the Empire Enterprise MIB The values for these variables are determined by executing a command on the host where the agent is running See the SystemEDGE Agent User
481. u can use the following MIB objects with the Monitor table to optimize row creation Table 31 Scalar Objects for Optimizing Row Creation ani mon UnusedIndex Read Only You can use this variable to optimize table row creation for the Monitor table Perform an SNMP Get of this variable to return an unused index number for the Monitor table monMatchDescr Read Write You can use this MIB object with the monMatchIndex MIB object to determine the index number that corresponds to a particular entry description Perform an SNMP Set of this MIB object to cause the agent to search through entries in the Monitor table and place the index value of the last entry whose description matches in the monMatchIndex MIB object monMatchIndex Read Only You can use this MIB object with monMatchDescr to match a particular entry description with its index number eHealth SystemEDGE User Guide 252 e Chapter 10 Configuring Threshold Monitoring Monitor Table Flags The monFlags column in the Monitor table is a 32 bit unsigned integer that can specify additional behavioral semantics for the corresponding Monitor table row By default the Monitor table row does the following Attempts to reinitialize itself Sends SNMP traps e Logs events through the syslog facility Invokes actions if they are configured You can set flag bits to alter these defaults The SystemEDGE agent interprets all flags in hexadecimal base 16 notation Figure 31 s
482. uires authentication you will need username password for it You also need SNMP read write access to SystemEDGE You also need your licensing account username passwd eHealth SystemEDGE User Guide Installing SystemEDGE on Solaris Systems 57 a Enter sysedge at the following prompt Product choose one sysedge svcrsp xchgmod iismod apachemod oramod sgqlmod b Enter the type of license you are requesting at the following prompt License Type choose one eval permanent usage based partner c Enter the IP address of the Web proxy server if applicable at the following prompt Web HTTP proxy server none d Enter the proxy user name if applicable at the following prompt Web HTTP proxy username none e Enter the password for that proxy user if applicable at the following prompt Web HTTP proxy password none f Enter the user name for the Web licensing account at the following prompt Web Licensing Account Username g Enter the password for the Web licensing account at the following prompt Web Licensing Account Password h Enter your name at the following prompt Your Name The installation script displays a message similar to the following licenseme licensing for host 127 0 0 1 was successful Concord SystemEDGE Agent Installation complete eHealth SystemEDGE User Guide 58 e Chapter 2 Installing the SystemEDGE Agent Installing SystemEDGE in a Non Default Directory for Solaris B
483. umn to active In this case when the management protocol set operation is issued to set the status column to active the values held in the agent supersede those used by the managed device eHealth SystemEDGE User Guide 522 Appendix D Textual Conventions for Row Status If the management station is prevented from setting the status column to active e g due to management station or network failure the conceptual row will be left in the notInService or notReady state consuming resources indefinitely The agent must detect conceptual rows that have been in either state for an abnormally long period of time and remove them This period of time should be long enough to allow for human response time including think time between the creation of the conceptual row and the setting of the status to active It is suggested that this period be approximately 5 minutes in length Conceptual Row Suspension When a conceptual row is active the management station may issue a Management protocol set operation which sets the instance of the status column to notInService If the agent is unwilling to do so the set operation fails with an error of wrongValue Otherwise the conceptual row is taken out of service and a noError response is returned It is the responsibility of the DESCRIPTION clause of the status column to indicate under what circumstances the status column should be taken out of service e g in order for the value of some other
484. under auto install The contrib subdirectory also includes an ntdist pl script which you can download from the SystemEDGE Contributed Information page You can run this script from the command line on Windows systems using Perl with the Win32 extension For complete instructions refer to http www concord com sysedge contrib 413 414 e Chapter 18 Deploying the SystemEDGE Agent SystemEDGE also provides the following deployment options e Using AdvantEDGE View Agent Deployment e Downloading the agent from a Web page e Distributing the agent through e mail Deploying SystemEDGE with AdvantEDGE View g _ If you are using SystemEDGE with AdvantEDGE View on Windows systems you can automatically deploy SystemEDGE agents and eHealth AIMs through AdvantEDGE View Agent Deployment To deploy SystemEDGE and eHealth AIMs from AdvantEDGE View 1 Click the Administration icon AdvantEDGE View displays the Administration page 2 Click the Agent Deployment icon AdvantEDGE View displays the AdvantEDGE View Agent Deployment form For details about completing this form refer to the eHealth AdvantEDGE View User Guide or the AdvantEDGE View Web Help How the Automated Deployment Works eHealth SystemEDGE User Guide AdvantEDGE View obtains a list of target systems to deploy including information on deployment options for each system checks for local files and verifies that the correct files for deployment exist on the syste
485. upported by the underlying Digital UNIX or Tru64 operating system on which the SystemEDGE agent is running The agent therefore does not create a Process Monitor table For a list of Process Monitor attributes that are not supported by Digital UNIX or Tru64 refer to the eHealth SystemEDGE Release Notes edgewatch internal error please report An internal SNMP library error has occurred within the program Report this error to Technical Support by sending an e mail to support concord ca com edgewatch invalid timeout value The timeout value that was passed to edgewatch was invalid so the utility did not perform the requested action If a timeout value is set it must be an integer that is greater than 0 edgewatch WSAStartup failed On Windows systems edgewatch was unable to initialize the WinSock library and could not communicate with the targeted agent The agent therefore did not perform the requested action GET failed edgewatch failed to get one of the request variables because of an error in the SNMP Get operation Verify that the community string and the target system hostname or IP address are correct eHealth SystemEDGE User Guide 476 e Appendix A Error Messages eHealth SystemEDGE User Guide GET_NEXT failed An error occurred while edgewatch was communicating with the SystemEDGE agent during an SNMP Get Next operation Verify that the community string target IP address and system name are correct Th
486. use this option to send a processClear trap Figure 42 on page 295 shows the default behavior whereby processClear traps are not sent 0x00000800 Match process name and arguments when targeting a process for monitoring By default the agent matches only against a process name Enabling this option causes the agent to apply the pmonRegExpr to both the process name and process arguments which is sometimes necessary to distinguish between similar processes or multiple invocations of the same application or binary Note This flag is valid for UNIX systems only You cannot set this flag if you are using the 0x00000100 flag Figure 43 on page 295 0x 10000 Do not perform any processStart processing If this flag is enabled SystemEDGE does not invoke actions log events or send traps when processStart events occur 0x00002000 Send up to X consecutive processThreshold traps and then send no more Enabling this feature places an upper boundary on the number of consecutive processThreshold traps and action executions that can occur when a process has exceeded a threshold Once the threshold expression transitions from True to False the row resets itself and the agent begins counting events from zero This flag also applies to action execution You can specify the value of x through the flag value field Event logging is unaffected by this flag bit For an example refer to 0x00001000 Send processThreshold traps only after the xth consecutive event
487. uto sol2 5 9 8035b1f8 643ab43 4 2 PL 1 You must provide the public key sysedge pluto sol2 5 9 8035b1f8f643ab43 4 2 PL 1 in this example to CA to receive your license key eHealth SystemEDGE User Guide Obtaining a License Key 109 2 Obtain your license key through one of the methods described in the following sections e Run the licenseme utility For more information refer to the next section Running the licenseme Utility e Complete the Web based licensing form through the Internet For more information refer to Using the Web Based Licensing Form on page 111 Send an e mail request to productlicensing ca com and place the returned license key in the appropriate license file For more information refer to Sending an E mail Request for a License Key on page 110 Run the CA supplied licenseutil pl script For more information refer to Using the licenseutil pl Utility on page 112 e Use AdvantEDGE View Agent Deployment to deploy and license your agents automatically For more information refer to Chapter 18 Deploying the SystemEDGE Agent Running the licenseme Utility You can obtain a license for the SystemEDGE agent by running the licenseme utility from the bin subdirectory of the SystemEDGE agent distribution This utility automates the interaction with the license Web server and therefore requires Web access either directly or through a Web proxy from the system that is
488. value For that reason SystemEDGE does not support the following counter types PERF_COUNTER_QUEUELEN_TYPE PERF_COUNTER_TEXT PERF_COUNTER_NODATA PERF_SAMPLE_BASE PERF_AVERAGE_TIMER PERF_AVERAGE_BASE PERF_COUNTER_MULTI_BASE PERF_RAW_BASE PERF_COUNTER_HISTOGRAM_TYPE eHealth SystemEDGE User Guide 408 e Chapter 17 Adding Windows Registry and Performance MIB Objects Configuring Windows Registry and Performance Variables Windows Registry and Performance variables are configured in the SystemEDGE agent configuration file sysedge cf When the SystemEDGE agent starts it configures these values and verifies that the value associated with each variable is accessible If not it prints an error message to sysedge log and does not create the MIB object Using the ntRegPerf Keyword Within the configuration file the keyword ntregperf defines the ntRegPerf variable You can use the ntRegPerf keyword to add entries in the ntregperf group as follows ntregperf LeafNumber Type Registry Key Value or ntregperf LeafNumber Type Performance Object Counter PerfInstance Table 80 describes the parameters for the ntRegPerf command Table 80 Parameters for the ntRegPerf Command Page 1 of 2 ntRegPerf variable number in the range of 1 through 128 that is being defined by this entry SNMP type for this entry The supported types are as follows Integer Counter Gauge Octetstring e TimeTicks Objectid e IPAddress eH
489. value of x through the flag value field Event logging is unaffected by this flag bit For an example of this behavior refer to Figure 35 on page 266 0x00000400 Send up to X consecutive monitor traps and then send no more Enabling this feature places an upper boundary on the number of consecutive monitor traps and action executions that can occur when a threshold has been exceeded Once the threshold expression transitions from True to False the row resets itself and the agent begins counting subsequent events at zero This flag also applies to action execution You can specify the value of x through the flag value field Event logging is unaffected by this flag bit For an example of this behavior refer to Figure 36 on page 268 Ox 00000 Flag value 0x00100000 Oxfff00000 Several flag bits utilize a value x for sending traps and executing actions The value x is specified as the high order 12 bits of the flag field Flag bits utilizing this field are mutually exclusive For an example of this behavior refer to Figure 31 on page 252 Monitor Table Actions The SystemEDGE agent provides several default parameters to the action commands when they are invoked These parameters are in addition to any parameters you specify in the action string and they are passed on the command line after those that you specify The default action parameters are the same as the parameters that are provided in the SNMP traps that the agent sends for
490. ver entries in sysedge mon For example if a Log Monitor table entry is contained in sysedge mon at index 10 anda configuration file directive is added to sysedge cf for index 10 of the Log Monitor table the entry defined in sysedge cf replaces the entry taken from sysedge mon Using the edgewatch Utility to Monitor Log Files To facilitate log file monitoring the SystemEDGE agent distribution includes the edgewatch command line utility edgewatch acts in a manager role to configure entries in the Log Monitor table and list entries that currently exist in the table The edgewatch utility is located in the bin subdirectory of the SystemEDGE agent distribution eHealth SystemEDGE User Guide 346 Chapter 13 Configuring Log File Monitoring You can use edgewatch to add delete set the status of or list entries in the Log Monitor table as follows edgewatch hostname port timeout community logfile command Table 55 describes the parameters of the edgewatch utility Table 55 edgewatch Utility Parameters Parameter Description hostname port timeout Specifies the hostname or IP address in dotted notation of the system on which the agent exists If the agent is running on an alternative UDP port for example 1691 you must specify that port number through a colon separator In addition you can specify an optional SNMP timeout value in seconds using a command separator community Indicates the particular SNMP communit
491. wapCapacity 30 memCapacity 31 memInUseCapacity 32 pageScans 33 eHealth SystemEDGE User Guide 180 e Chapter 7 Systems Management MIB For descriptions of these MIB objects refer to the empire asn1 file in the doc subdirectory of the SystemEDGE agent distribution Interprocess Communication Queues Shared Memory and Semaphores A semaphore is a value in operating system or kernel storage that a process can check and change to coordinate activities in which multiple process compete for the same operating system resources eHealth SystemEDGE User Guide You can track the IPC mechanisms that are in use on the system by retrieving the appropriate MIB table e Message Queue table e Shared Memory table Semaphore table A row in each of these tables represents one instance of IPC usage The columns differ for each table The columns of the Message Queue table provide the message queue ID key mode owner group and size The columns of the Shared Memory table provide the shared memory segment ID key mode owner group and size The columns of the Semaphore table provide the semaphore ID key mode and owner Figure 9 shows a sample Shared Memory table Interprocess Communication Queues Shared Memory and Semaphores 181 SNMP Table Display Tablet shmemTable Path 1 5 6 1 4 1 546 1 1 9 2 1 Rowst3 Columne 8 Instance shmem II shmemkKey shmemMode shmenQwner shmembroup shmemSegsz shmemNlcks shmemDel
492. watch ntevent keyword to specify initial entries to the NT Event Monitor Table You can specify event logs that you want the agent to monitor by adding appropriate entries for the files types and expressions you want to monitor to the sysedge cf file eHealth SystemEDGE User Guide 370 e Chapter 14 Configuring Windows Event Monitoring Using the watch ntevent Directive You can use the watch ntevent directive to add entries to the ntEventMonTable as follows watch ntevent ntEventMonIndex ntEventMonFiags ntEventMonLog ntEventMonTypeFilter ntEventMonSrcFilter ntEventMonDescFilter ntEventMonDescr ntEventMonAction Table 67 describes the parameters of the watch ntevent directive Table 67 Parameters for the watch ntevent Directive Page 1 of 2 Parameter Description Row number of the entry to be created in the NT Event Monitor Table ntEventMonFlags Hexadecimal flags for example 0x00001 that direct the additional behavioral semantics of this entry ntEventMonLog Event log to monitor One of the following e Application e System e Security ntEventMonTypeFilter Event type to match for this entry The following are valid types e Error Warning Information Success Failure All Type All indicates that all event types should match ntkventMonsrcriit Regular expression to apply when scanning the Event Source attribute for each event in the log You must enclose this value in single quotation marks For more
493. which indicates that the conceptual row is available for use by the managed device e notInService which indicates that the conceptual row exists in the agent but is unavailable for use by the managed device e notReady which indicates that the conceptual row exists in the agent but is missing information necessary in order to be available for use by the managed device 913 914 e Appendix D Textual Conventions for Row Status eHealth SystemEDGE User Guide e createAndGo which is supplied by a management station wishing to create a new instance of a conceptual row and to have it available for use by the managed device e createAndWait which is supplied by a management station wishing to create a new instance of a conceptual row but not to have it available for use by the managed device e destroy which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row Whereas five of the six values all except notReady may be specified in a management protocol set operation only three values will be returned in response to a management protocol retrieval operation notReady notInService or active That is when queried an existing conceptual row has only three states it is either available for use by the managed device the status column has value active it is not available for use by the managed device though the agent has sufficient information to make it so the
494. will continue to perform Windows event monitoring on all other entries An NT Event Monitor table entry can become notReady when the SystemEDGE agent is unable to read the corresponding Windows event log file This error occurs only when there are errors on the underlying Windows system odm_ initialize failed On AIX systems the SystemEDGE agent uses an odm library for obtaining hardware and device information This message indicates that initialization of that library failed Consequently it may not support device information openProcess failed on pid eHealth SystemEDGE User Guide On Windows the SystemEDGE agent failed to open a process for statistics retrieval because the process may not be in existence anymore The agent will continue to operate normally and will continue to support the process table SystemEDGE Agent Error Messages 463 openProcessToken failed on pid On Windows the SystemEDGE agent failed to open a process for statistics retrieval because the process may not be in existence anymore The agent will continue to operate normally and will continue to support the process table openprom device not supported Upon startup on many UNIX systems the SystemEDGE agent attempts to discover the devices contained in the underlying system using whatever operating system support is available This error messages indicates that the underlying system does not support the openprom device which is used to determine syste
495. with the setstatus operation this value specifies the RowStatus textual convention value to use in setting the status of a row in the Log Monitor table The Row Status parameter is an integer that can take on one of the following values active 1 notInService 2 destroy 6 For more information about the Row Status textual convention refer to Appendix E Sample Uses of the edgewatch Utility This section provides examples for using the edgewatch utility Listing Entries in Log Monitor Table The following example lists the contents of the SystemEDGE agent s Log Monitor table edgewatch 127 0 0 1 public logfile list Adding a Log Monitor Entry The following example instructs the SystemEDGE agent to add a new entry to the Log Monitor table at table index 5 to search for su failures on an HP UX system The agent runs the script local bin mail2admin when it finds a match edgewatch 127 0 0 1 private logfile add 5 0x00 usr adm sulog SU su attempt WARNING local bin mail2admin eHealth SystemEDGE User Guide Removing Log Monitoring Entries 349 Deleting a Log Monitor Entry The following example deletes an entry from an agent s Log Monitor table at table index 5 edgewatch 127 0 0 1 private logfile delete 5 Disabling a Log Monitor Entry The following example disables the Log Monitor table entry at table index 5 by setting that entry s status to notInService 2 The entry will remain in the table
496. ws NT 4 0 Windows 2000 and Windows XP NT System Group Use the NT System group to determine the following eHealth SystemEDGE User Guide Operating system version build and service pack numbers Kernel configuration parameters Cluster information Other pertinent system information about the Windows system Following are the NT System group MIB objects ntSystemVersion 1 ntBuildNumber 2 ntServicePackNumber 3 ntWorkstationOrServer 4 ntfsDisable8dot3 NameCreation 5 ntWin31FileSystem 6 ntCriticalSectTimeout 7 ntGlobalFlag 8 ntloPageLockLimit 9 ntLargeSystemCache 10 ntPagedPoolSize 11 ntNonPagedPoolSize 12 Windows Specific Groups 189 ntPagingFiles 13 ntSystemPages 14 ntOptionalSubsystem 15 ntCmdlineOptions 16 ntLPTTimeout 17 ntDosMemSize 18 ntWowCmdline 19 ntWowSize 20 ntUserFullScreen 21 ntHistoryBufferSize 22 ntNumberHistoryBuffers 23 ntQuickEdit 24 ntScreenBufferSize 25 ntWindowSize 26 ntWindowsAppInitDLLs 27 ntWindowsDeviceNotSelectedTimeout 28 ntWindowsSpooler 29 ntWindowsSwapDisk 30 ntWindowsXmitRetryTimeout 31 ntSystemRoot 32 ntBuildType 33 ntSysStartOptions 34 ntSysBiosDate 35 ntSysBiosVersion 36 ntVideoResolution 37 ntCrashDumpEnabled 38 ntLogEvent 39 ntOverwrite 40 ntSendAlert 41 ntIsClustered 42 eHealth SystemEDGE User Guide 190 e Chapter 7 Systems Management MIB e ntClusterName 43 e ntClusterMembers 44 e ntClusterIsActive 45 e ntClust
497. xample if you have configured the SystemEDGE agent to disallow SNMP Set operations the edgemon utility will not work In this case you need to remove the entry from the NT Event Monitor Table by editing the sysedge mon file and removing the entry from it Because this is an active file you will need to stop the SystemEDGE agent before you edit it For more information on the format of this file refer to Appendix C eHealth SystemEDGE User Guide 378 Chapter 14 Configuring Windows Event Monitoring For example to delete row 14 1 Stop the SystemEDGE agent 2 Open sysedge mon for editing delete the entry for nteventmon row 14 and save the file 3 Open sysedge cf for editing delete the entry for nteventmon row 14 if it exists and save the file 4 Restart the SystemEDGE agent eHealth SystemEDGE User Guide Configuring History Collection This chapter describes the SystemEDGE agent s history sampling capability It also explains how you can instruct the agent to monitor and store the values of MIB variables over time for future retrieval by a manager History Collection The SystemEDGE agent can track the values of various integer based MIB objects counters gauges and so on over time and store them for later retrieval This functionality commonly referred to as history sampling can greatly reduce the amount of management station polling across the network Instead of having to continuously poll to coll
498. y a system for Log Monitor table information by selecting the system you want to monitor from the System list selecting Logfile Monitoring from the Configuration list and clicking the Configuration icon For more information refer to the AdvantEDGE View Web Help Figure 52 shows a sample AdvantEDGE View Log Monitor table Logfile aie Last Last Logfile Description Logfile Regexpr Traps Last Action ee ee a E Update oo Oct 4 11 09 22 aviewdemo 48 days no slide attempt var log daemon log slide Fe Se S ea successful by 191 832 53 eal action 0x0 pse slide Rlogin 46 days no attempt Ivarnogsysios in Insiogn o ao000 00 00 no match 219 20 31 54 Sa 0x0 N Oct 30 13 34 58 aviewdemo Telnet 46 days no ar log syslog in telnet in telnetd 5639 connect 219 beni 0x0 Q attempt 20 28 i from egyptian empire com 20 31 54 action Oct 30 13 39 28 aviewdemo 46d 46 days no a eta ao in ftpd S666 connect fram 219 20 31 54 action unixserver ftp attempt var log syslog in ftp 0x0 Thu Nov 1 16 47 30 2001 Monitor 8 days error client 141 151 44 10 48 days no AIGUSER HT Ce ee cay Fear ean 23 40 39 user tech not 2 988 494 23 39 56 action Ae iaviewbin mainframe a 22 cclerror error VontaviewWvartog access_log log egi bin grin 400 9 9 o e000 00 00 no match match 51 51 890 984 984 51 890 984 2 days NO oxo 16 56 09 action 1000 Hii Narilog syslo core dumped 0 0 00 00 no match 219 pees AS bea
499. y default the SystemEDGE agent for Solaris is installed in the opt EMPsysedge directory You can install SystemEDGE in a different directory under the opt directory but you cannot change the EMPsysedge directory name For example you can install SystemEDGE in opt Concord EMPsysedge To install SystemEDGE in a different directory for Solaris 1 Create an administration text file that specifies the new installation directory as follows basedir opt Concord mail instance unique partial ask runlevel ask idepend ask rdepend ask space ask setuid ask conflict ask action ask 2 Enter the following from a command prompt to instruct the pkgadd utility to use the text file you created myadmin file in this example to install the agent to the directory you specified pkgadd a myadmin file d sysedge pkg This example installs the agent in opt Concord EMPsysedge 3 Follow the installation prompts as described in Adding the SystemEDGE Agent Package on page 52 eHealth SystemEDGE User Guide Installing SystemEDGE on Windows Systems 59 4 If you are installing any eHealth AIMs or other SystemEDGE modules install them in the plugins subdirectory of the directory you specified for example opt Concord EMPsysedge plugins Installing SystemEDGE on Windows Systems This section describes how to install the SystemEDGE agent on Windows systems See the Preface for a list of supported systems and versions
500. y is index 17 in the Monitor table eHealth SystemEDGE User Guide Threshold Monitoring Examples 271 60 indicates that the agent should calculate the rate every 60 seconds delta is the sample type because the object being monitored is a MIB II ifEntry counter 1000 specifies the value to use in the comparison If the change in rate is greater than gt 1000 the agent sends a trap message to all configured managers indicates that no action is specified Monitoring Number of SNMP Packets Received The following example configures the SystemEDGE agent to monitor the rate at which the agent receives SNMP requests monitor oid snmpInPkts 0O 18 0x0 30 delta gt 4000 Monitor SNMP Packets The values in this example are defined as follows snmpInPkts 0 is the OID that indicates the MIB II object instance to sample 18 specifies that the entry is index 18 in the Monitor table 30 indicates that the agent should calculate the rate every 30 seconds delta is the sample type because the object is a counter 4000 specifies the value to use in the comparison If the change in rate is greater than gt 4000 the agent sends a trap message to all configured managers indicates that no action is specified Monitoring Space on the Root File System The following example configures the SystemEDGE agent to monitor the root file system and to send a trap message when it becomes more than 95 full monitor fi
501. y string to use when performing the specified command The community string should have read write access on the target agent for add delete and setstatus operations For the list operation the community string needs only read access command Specifies the command and associated arguments Supported commands include add setstatus delete and list For more information about the commands refer to the next section edgewatch Commands for Log File Monitoring edgewatch Commands for Log File Monitoring You can use the edgewatch command for log file monitoring as follows add logMonIndex logMonFlags logFilename logMonRegExpr lLogMonDescr lLogMonAction setstatus logMonIndex status delete lLogMonIndex ese eHealth SystemEDGE User Guide Using the edgewatch Utility to Monitor Log Files 347 Table 56 describes the arguments for the edgewatch monitoring commands Table 56 edgewatch Command Arguments Page 1 of 2 logMonIndex Specifies the row in the table Rows are indexed starting at 1 An index of 0 is not permitted Because SNMP does not include a Create PDU type new table entries are created as a side effect of setting the columnar values for a non existent row Therefore you must include this value for add operations in order to specify the table index of an unused row to use for row creation LogMonFlags Specifies the hexadecimal flags for example 0x00001 that directs the additional behavior of this
502. ysedge cf file to the etc UNIX or SystemRoot system32 Windows directory Keep in mind that if you performed an upgrade instead of a clean installation the installation does not overwrite your existing sysedge cf sysedge lic or sysedge mon files You can compare the existing versions with the new versions which are installed in the config subdirectories modify the new versions save any information that you want to keep from the existing files and then copy the new files into the etc for UNIX and SystemRoot system32 for Windows directories ee H Sample sysedge cf File 119 To copy the file manually For UNIX systems enter the following cp config sysedge cf etc For Windows systems enter the following copy config sysedge cf t SystemRoot system32 Sample sysedge cf File The following is a sample sysedge cf file Concord SystemEDGE configuration file Copyright 2004 Concord Communications Ine http www concord com support http www concord com sysedge http www concord com sysedge contrib Tell the agent that we do not want to support Empire s User and Group tables due to security policies Default is to support those groups no_usergroup_table Tell the agent not to support its remoteShell MIB object group due to security policies default is to support this group no_remoteshell group Tell the agent not to query the status of serial devices other than the keyboard and mouse the Agent will re
Download Pdf Manuals