Home
DIGITAL 7 YEAR LIFE CARBON MONOXIDE
Contents
1. Advisory service for domestic and solid fuel appliances HETAS Trade association for solid fuel engineers OFTEC Trade association for Oil Fired Appliance engineers NACS National Association of Chimney Sweeps Institute of Plumbing and Heating Engineers 0800 111 999 24 Hours 0800 408 5500 0845 601 4406 0845 223 3033 0845 658 5080 01785 811 732 01708 472 791 TECHNICAL INFORMATION Detector Specifications Model CO 9D Sensor Type Electrochemical Sensor Life 7 Years Alarm Sound Level 85dB at 1 metre 3 feet Power Pack Life 7 years Life of product Temperature Range 10 C 14 F to 40 C 104 F Operating Humidity Range 30 90 RH Weight 120 grams 4 2302 Certified to BS EN 50291 2001 This FireAngel carbon monoxide detector is designed to continuously monitor for CO lts response times meet the requirements of BSI standard BS EN 50291 2001 The alarm will sound e Between 60 and 90 minutes when exposed to 5Oppm of CO e Between 10 40 minutes when exposed to 100ppm of CO Within 3 minutes when exposed to CO levels of 300ppm more WARNING APPARATUS CONFORMING TO THIS STANDARD MAY NOT PROTECT PEOPLE WHO ARE AT SPECIAL RISK FROM CARBON MONOXIDE EXPOSURE BY REASON OF AGE PREGNANCY OR MEDICAL CONDITION IF IN DOUBT CONSULT YOUR DOCTOR A CARBON MONOXIDE DETECTOR IS NOT A SUBSTITUTE FOR A SMOKE ALARM OR A COMBUSTIBLE GAS DETECTOR REPLACE UNIT AFTE
2. drop below 10 C or exceed 40 C Where dirt and dust may block the sensor damp or humid location for example a bathroom In the immediate vicinity of the cooking appliance In direct sunlight as this could affect the accuracy of the temperature display considerably e Within 1m 3 feet of mobile phones HOW TO INSTALL YOUR DETECTOR NOTE This apparatus should be installed by a competent person who feels able to install it according to the instructions Firstly write the installation date your detector in the area provided We recommend that your detector is installed on the wall To mount on a wall or ceiling Please ensure that you use the screws provided as they were chosen specifically for use with this product Use the template below for guidance on marking hole positions Drill holes into the wall Insert the plastic wall plugs Screw in the screws Ensure screws are protruding from the wall by 3mm to allow detector to slot onto screws To place on a shelf The base of the detector has been designed to allow it to stand freely on a shelf WARNING When placing on a shelf please adhere to the same positional recommendations as described on pages 5 and 6 Drill hole spacing 65mm POWER PACK ACTIVATION See diagram opposite a Your detector comes complete with an integrated power pack that will provide power for its entire operational life To activate the power pa
3. and the alarm LED below will illuminate red You should perform this test once per week Peak Level Reading feature The alarm will record the highest reading of CO that is has detected in the last 4 weeks This information is useful if your alarm has sounded so you can see the highest level of CO detected during that time It is also useful to check periodically to see if a readable level of CO has been detected for a short time but not long enough to trigger a full alarm The peak level reading is shown briefly every time you press Test Mode button and will look something like the image below eae ppm Gd NOTE It is possible and quite normal for the peak level to remain at Oppm i e this simply means that the alarm has not detected any CO in the last 4 weeks The Peak Level reading will be reset to Oppm whenever a Sensor Test is carried out See the next section for Sensor Test SENSOR TEST CAUTION Sensor testing should only be performed by a responsible adult This test should only be performed once a month Excessive testing will shorten the life of the power pack NOTE We suggest the use of an incense stick or cigarette as the way in which these products burn produces a readable localized amount of CO A readable level of carbon monoxide will not be given off by other sources of smoke for example an extinguished candle or match Step 1 If the alarm is wall mounted unhook it from
4. appliances without proper knowledge skill and expertise Use a gas cooker for heating a room Operate unvented gas burning appliances using paraffin or natural gas in closed rooms e Operate petrol powered engines indoors or in confined areas Ignore a safety device when it shuts an appliance off Always Buy appliances accepted by a recognised testing laboratory Install appliances according to the manufacturer s instructions Have appliance installations carried out by professionals for gas appliances engineers should be registered Have your appliances checked regularly by a qualified service engineer Have your chimneys and flues cleaned professionally every year Make regular visual inspections of all fuel burning appliances e Do not barbecue indoors or in an attached garage Open windows when a fireplace or oil solid fuel cooker is in use Only install CO detectors that meet the requirements of BS EN 50291 2001 in your home Be aware of CO poisoning symptoms see page 3 EDUCATE YOURSELF AND YOUR FAMILY ON THE SOURCES AND SYMPTOMS OF CO POISONING AND HOW TO USE YOUR CARBON MONOXIDE DETECTOR WHERE TO INSTALL YOUR DETECTOR This detector should be used in domestic applications only WARNING This detector will only indicate the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be present in other areas In which room should the detector be in
5. is particularly dangerous because the victim usually does not wake up Symptoms of CO poisoning The following symptoms may be related CO poisoning which all household members should be made aware of Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate Extreme Exposure Unconsciousness convulsions cardiorespiratory failure death Your FireAngel detector monitors level of CO as parts per million ppm in the atmosphere surrounding the detector The maximum allowable concentration for continuous exposure for healthy adults in any 8 hour period as recommended by the Occupational Safety and Health Administration OSHA Slight headache fatigue dizziness nausea after 2 3 hours 35ppm 200ppm Frontal headaches within 1 2 hours life threatening after 3 hours 400 800ppm Dizziness nausea and convulsions within 45 minutes Unconsciousness within 2 hours Death within 2 3 hours Should you suspect CO may be affecting you or your family open the doors and windows of your property to ventilate turn off your appliances and evacuate the premises At this time the authorities should be contacted to locate the source of the carbon monoxide before re entering the building for usefull 3 contact numbers see page 17 Medical attentio
6. its sensor and circuitry If any of these settings are found to be incorrect the detector will emit a single chirp once per minute and the display will show Err for error and an error code cycling between Errand the particular error code Low power pack signal If the power pack becomes low then the detector will emit a single chirp once per minute and the low power pack icon will flash on the screen IMPORTANT A single chirp once per minute together with an error signal 13 or low power pack warning does NOT mean that the detector has detected carbon monoxide If you experience an error condition or low power pack warning and the product is still within warranty then contact technical support If the product is no longer in warranty replace immediately IMPORTANT The selected power pack was chosen to provide power beyond the lifetime of the product in particular the sensor under normal operating conditions The operational life of the sensor is seven years for this reason the detector should be replaced after seven years from the date of installation FireAngel Technical Support Line 9 00am 5 00pm Monday Friday Telephone 0800 141 2561 1 800 523171 in EIRE email technicalsupport fireangel co uk MAINTAINING TESTING YOUR DETECTOR Maintenance Your detector will alert you to potentially hazardous CO concentrations in your home when maintained properly To keep your FireAngel dete
7. 637 S2 R1 Technical Support Line 0800 141 2561 UK Textphone users dial 18001 0800 141 2561 Eire dial 1 800 523171 Email technicalsupport fireangel co uk Web www fireangel co uk FireAngel Ltd Vanguard Centre ae i BS EN 50291 2001 Sir William Lyons Road KM 551504 Coventry CV4 7EZ UK 0 Sprue Aegis GNO0637 51 R1
8. CO 9D User Manual Firefingel DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM CONTENTS NTRODUCTION FEATURES CARBON MONOXIDE AND HOW IT CAN AFFECT YOU AND YOUR FAMILY WHERE TO INSTALL YOUR DETECTOR HOW TO INSTALL YOUR DETECTOR POWER PACK ACTIVATION POWER PACK DEACTIVATION OPERATING FEATURES SENSOR TEST UNDERSTANDING THE PRODUCT S INDICATORS MAINTAINING TESTING YOUR DETECTOR CO N 12 14 WHAT DO IN THE EVENT OF AN ALARM USEFUL NUMBERS TECHNICAL INFORMATION DISPOSAL 7 YEAR WARRANTY RETURNS PRODUCT RANGE NOTES DISABLING TAB STORAGE PAGE 15 17 18 20 21 21 22 Note This User Manual is also available in large text and other formats Please call 0800 141 2561 for further information INTRODUCTION FEATURES Congratulations You ve made wise investment an innovative product and your personal safety The CO 9D_ Digital Carbon Monoxide Alarm is one of a new generation of domestic life safety products from FireAngel Limited which combines the latest technology and innovative design to provide an aesthetically pleasing and effective contribution to your home safety The FireAngel range of products is constantly being improved and expanded Please visit www fireangel co uk to find out about the latest additions to our product range FireAngel manufactures some of the most technologically advanced carbon monoxide detectors in the world An advance
9. R 7 YEARS OF OPERATION DISPOSAL Waste electrical products should not be disposed of with regular household waste Please recycle where facilities exist Check with your local authority retailer or manufacturer for recycling disposal advice as regional variations apply The power pack should be deactivated before disposal To do this insert the two ends of the metal clip on the end of the disabling tab back in to the socket located on the underside of the detector see page 9 If the disabling tab is no longer available then the clip can be replicated by opening out a thin metal paper clip into a U shape You can also return your carbon monoxide detector to us for disposal For return address see the section on Returns Please include a note confirming the product is being returned for disposal WARNING DO NOT ATTEMPT TO OPEN DO NOT BURN 7 YEAR WARRANTY FireAngel Ltd warrants to the original purchaser that its enclosed carbon monoxide alarm be free from defects in materials and workmanship under normal residential use and service for a period of 7 seven years from the date o purchase Provided it is returned with postage paid and proof of purchase date FireAnge Lid hereby warrants that during the 7 seven year period commencing from the date o purchase FireAngel Ltd at its discretion agrees to replace the unit free of charge The warranty on any replacement CO 9D alarm will last for the remainder of th
10. all and ceiling mounted apparatus the following applies a The apparatus should be at a horizontal distance of between 1m and 3m from the potential source b If there is a partition in a room the apparatus should be located on the same side of the partition as the potential source Carbon Monoxide detectors in rooms with sloped ceilings should be located at the high side of the room In addition to the above the following must be observed If the apparatus is located on a wall 6 a it should be located close to the ceiling b it should be located at a height greater than the height of any door or window c it should be at least 150mm from the ceiling If the apparatus is located on the ceiling a it should be at least 300mm from any wall and any ceiling obstruction e g light fittings Apparatus located in sleeping rooms and in rooms remote from a fuel burning appliance Apparatus located sleeping rooms or located in rooms remote from the fuel burning appliance should be located relatively close to the breathing zone of the occupants Where not to put the detector The apparatus should not be installed In an enclosed space for example in a cupboard or behind a curtain Where it can be obstructed for example by furniture Directly above a sink ext to a door or window ext to an extractor fan ext to an air vent or other similar ventilation openings area where the temperature may
11. ck you need to pull the disabling tab see image This will in turn pull out the metal disabling clip which is attached to the end of the tab from the disabling socket which is situated on the underside of the detector Retain the disabling tab for future use by taping it to page 22 of this manual b When the detector is activated the screen will display all of the icons then after a few seconds will show the current CO level The power indicator LED below the f symbol will also flash green once every minute indicate that the detector is receiving power from the power pack and is fully operational symbol will also flash briefly on the LCD screen approximately once every minute Test the sounder power pack and circuitry by pushing the centre of the Test Mode button briefly to confirm that the detector is operating properly The sounder will sound as soon as the button is pressed and the Alarm LED will illuminate red indicating that the sounder is working and the power pack is providing power to the unit You ll notice that the display will switch to temperature mode this is explained later in the manual press the button again to return to the CO display This test for the sounder power pack and circuitry should be performed on a weekly basis and should be continued for the lifetime of the product WARNING Prolonged exposure to the sounder in close proximity to your ears may damage your
12. ctor in proper working order and to ensure that the sensor will last for the lifetime of the product it is recommended that you e Test the sounder power pack and circuitry of your detector at least once per week by pressing the Test Mode button briefly see page 10 Perform the Sensor Test once every month see page 11 Keep the detector free of dust by gently vacuuming the case with a soft brush attachment once per month To prevent the possibility of contaminating the sensor in your detector and thus affecting its reliability Never use cleaning solutions on your detector Simply wipe with a slightly damp cloth Do not paint the detector Do not spray aerosols on or near the detector Do not use any solvent based products near the detector Move the detector to a safe location and store in a plastic bag before painting wall papering or performing any other activities using substances that emit strong fumes Remember to remove it from the bag and replace the detector when these activities are finished Failure of any test should be reported to the Technical Support Team see page 21 for contact details Do not attempt to repair your CO detector Do not remove any screws or open the main casing of your detector Any attempt to do so may cause malfunction and will invalidate the warranty WHAT TO DO IN THE EVENT OF AN ALARM WARNING A loud alarm is a warning that unusually high and pot
13. d electrochemical sensor designed to accurately measure low levels of carbon monoxide CO providing an early warning of toxic CO levels in your home Detects carbon monoxide continuously Resistant to false alarms caused by normal household contaminants Sounds a loud 85aB alarm at 1 3 to alert you in case of an emergency Test Mode button Regular selfcheck to ensure detector is operating correctly Can be free standing or easily mounted on a wall Portable ideal for travelling Certified to the European Carbon Monoxide alarm Standard BS EN 50291 2001 7 year warranty Multifunction LCD screen Digital room thermometer CARBON MONOXIDE AND HOW IT CAN AFFECT YOU AND YOUR FAMILY Carbon monoxide is a dangerous poisonous gas that kills hundreds of people each year and injures many more It is often referred to as the silent killer because it has no odour or taste and cannot be seen Like oxygen CO enters the body through the lungs during the normal breathing process It competes with oxygen by replacing it in the red blood cells thereby reducing the flow of oxygen to the heart brain and other vital organs In high concentrations CO can kill in minutes Many cases of reported carbon monoxide poisoning indicate that while victims are aware they are not feeling well they become disorientated and unable to save themselves by either exiting the building or calling for assistance Exposure during sleep
14. e period the original warranty in respect of the alarm originally purchased that is from the date of original purchase and not from the date o receipt of the replacement product FireAnge Lid reserves the right to offer an alternative product similar to that being replaced if the original model is no longer available or in stock This warranty applies to the origina retail purchaser from the date of original retai purchase and is not transferable Proof of purchase is required This warranty does not cover damage resulting from accident misuse disassembly abuse or lack of reasonable care of the product or applications not in accordance with the user manual It does not cover events and conditions outside of FireAngel Ltd s control such as Acts of God fire severe weather etc It does not apply to retail stores service 20 centres or any distributors or agents FireAngel lid will not recognise any changes to this warranty by third parties FireAngel shall not be liable for any incidental or consequential damages caused by the breach of any expressed or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration for 7 seven years This warranty does not affect your statutory rights Except for death or personal injury FireAngel Ltd shall not be liable for any loss of use damage cost or expe
15. entially lethal levels of carbon monoxide are present Never ignore this alarm further exposure can be fatal Immediately check residents for symptoms of carbon monoxide poisoning and contact the proper authorities to resolve all CO problems NEVER IGNORE ANY ALARM Please carefully review this owner s manual to ensure that you know what actions to take in the event of an alarm What to do during an alarm Keep calm and open the doors and windows to ventilate the property Stop using all fuel burning appliances and ensure if possible that they are turned off Evacuate the property leaving the doors and windows open Contact your gas or other fuel supplier their emergency number keep the number in a prominent place Write your fuel supplier s emergency number here see page 17 for more useful numbers Do not re enter the property until the alarm has stopped When exposed to fresh air it can take up to 10 minutes for the sensor to clear and the alarm to stop depending on the level of carbon monoxide detected Get medical help immediately for anyone suffering the effects of carbon monoxide poisoning headache nausea and advise that carbon monoxide poisoning is suspected Do not use the appliance again until it has been checked by an expert In the case of gas appliances the engineer must be registered USEFUL NUMBERS National Gas Emergency Service Gas Safe register Solid Fuel Association
16. hearing Under normal operating conditions the power pack will last for the lifetime of the product i e 7 years The detector will not protect against the risk of carbon monoxide poisoning when the power pack has drained WARNING Prolonged exposure to extreme high or low temperatures may reduce the life of the power pack POWER PACK DEACTIVATION Your CO 9D is portable making it ideal for aking with you on holiday You will need to deactivate your detector when travelling or even when storing e g when decorating Fitting is the reverse of removal To deactivate he detector the two ends of the metal clip must be inserted into the corresponding holes in the disabling socket located on the underside of he detector see image You can ensure that he product is disabled by pressing the test button if there is no sound from the sounder hen the clip has been fitted correctly he clip must remain in the disabling socket to keep the power pack deactivated NOTE If the disabling tab is no longer available then the clip can be replicated by opening out a thin metal paper clip into a U shape OPERATING FEATURES Your FireAngel detector offers many features which set it apart from other CO detectors on the market today Standby mode The alarm can display two views when normal standby mode the current level of CO or the current room temperature in degrees centigrade C When the alarm is showi
17. n should be sought for anyone suffering the effects of poisoning headache nausea see page 3 Common sources of CO Oil and gas boilers Portable generators Oil or solid fuel cookers Gas or paraffin heaters Barbecues Clogged chimneys Wood or gas fireplaces Cigarette smoke Gas appliances Any fossil fuel burning appliance WARNING This FireAngel carbon monoxide detector is not a combustible gas detector nor a smoke detector Please install the proper detectors to detect combustible gases or smoke This CO detector should not be seen as a substitute for the proper installation use and maintenance of fuel burning appliances including appropriate ventilation and exhaust systems nor the sweeping of chimneys WARNING Variables relating to your fuel buring appliances can change at any point eg the flue or chimney could suddenly become blocked or damaged appliances may stop running correctly or circumstances in neighbouring properties 4 may change resulting in the presence of carbon monoxide For this and other reasons do not use this carbon monoxide detector on an intermittent basis or as a portable detector for trying to trace one source of the spillage of combustion products from fuel burning appliances or from chimneys Do not GNORE ANY WARNING FROM YOUR CO DETECTOR Burn charcoal inside your home caravan ent or cabin nstall convert or service fuel burning
18. ng the current CO Level you will see something similar to the following eee Ii PPM FireAngel s unique digital read out displays the amount of CO that the sensor is detecting shown in parts per million PPM It is designed to indicate levels from 1 to 999PPM NOTE Ambient background levels between OPPM and 10PPM will show as OPPM When the alarm is showing the current temperature you will see something similar to the following bec In both modes you will notice symbol appear briefly in the top left hand corner of the screen once every minute This is an additional indication to show you that the alarm is operating as well as the flashing green LED To switch between CO and temperature view simply press the Test Mode button briefly The unit will also sound when pressing the button to switch between the two display modes You will also notice that when switching between modes the display will change slightly this is because the alarm is displaying the Peak Level CO reading that it has recorded in the last 4 weeks please see the following peak level reading feature section for further description NOTE If the alarm is in temperature view and detects CO it will automatically switch back to CO display mode Power pack sounder and circuitry test Pressing the Test Mode button will also test the power pack sounder and circuitry of the alarm The unit will sound
19. nse relating to this product or for any indirect or consequential loss damages or costs incurred by you or any other user of this product RETURNS PRODUCT RANGE We recommend that you contact the FireAngel Technical Support Line in the first instance on 0800 141 2561 text phone users dial 18001 0800 141 2561 callers from dial 1 800 523171 As we may be able to remedy the problem quickly over the phone this is to prevent unnecessary returns that take a longer time to process Alternatively email technicalsupport fireangel co uk If there is a fault that we are unable to resolve then our technical support team member will provide you with a returns authority number so that your product can be returned for testing To return your FireAngel smoke alarm under warranty send it suitably packed with the power pack deactivated see page 9 for instructions with postage paid a note indicating the returns authority number and describing the reason for return with proof of purchase to FireAngel Limited Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK FireAngel Lid manufactures an extensive range of home safety products including smoke alarms carbon monoxide detectors fire extinguishers and remote warning devices For more details visit www fireangel co uk NOTES STORE DISABLING TAB HERE Tape disabling tab here for future use 22 NOTES 23 NOTES 24 Ref GNO
20. of CO e Within 3 minutes when exposed to a minimum of 300ppm of CO Alarm silence lt is possible to temporarily silence G the alarm up to two times if the level BA CO that triggered the alarm is less than 200 After ventilating the property you can temporarily silence the alarm by pressing the Test Mode button the alarm will stop and the silence mode symbol will appear on the screen The silence mode will last for up to 3 mi remains too high the a or if the level of CO then the detector will nutes If the CO level arm will trigger again rises above 200 automatically re enter alarm mode If the level of CO has fallen to a satisfactory level he silence mode icon will disappear the uni will exit alarm mode and the segments of the bar graph will slowly disappear as the CO in the sensor clears Alarm in absence If the Peak level reading symbol is lt showing on screen but there is no full alarm sound and you are not pressing the test button then your detector is warning that it has detected Carbon Monoxide in your absence Immediately vacate the premises and seek medical attention for anyone suffering the effects of CO poisoning headache nausea see page 3 Treat this as a serious warning Call a qualified technician and have the problem investigated and rectified immediately For usefull contact numbers see page 17 Error signal 5 The unit continuously checks the settings of
21. sor please contact the technical support team see page 21 for freephone and email contact details UNDERSTANDING THE PRODUCT S INDICATORS Digital Display The LCD screen has many icons with one or more being shown at any one time lo ie be baer Bar Graph to show early build up of CO To understand the role of the product indicators please refer to section Carbon Monoxide and how it can affect your family on page 3 The alarm has a bar graph which mimics the way CO levels build up in the blood stream The response times of the alarm are determined by the European Standard BS EN 50291 2001 so the alarm will only sound when it has detected CO for a prescribed length of time the higher the level of CO the quicker the alarm must sound However with FireAngel s CO 9D there is an early visual warning that CO is present When CO is first detected the alarm indicates it s presence by displaying the level on the screen in parts per million ppm If CO continues to be present additional bars will appear on the graph When the graph is full i e the 6th segment is shown the unit will sound a loud audible alarm 85 dB at Im 3 feet and the Alarm LED below the symbol on the front of the detector will flash red once every second The Alarm will sound Between 60 and 90 minutes when exposed to a minimum of 5 of CO Between 10 and 40 minutes when exposed to a minimum of 100ppm
22. stalled Ideally an apparatus should installed in every room containing a fuel burning appliance Additional apparatus may be installed to ensure that adequate warning is given for occupants in other rooms by locating apparatus in e Remote rooms in which the occupani s spend considerable time whilst awake and from which they may not be able hear an alarm from apparatus in another part of the premises and Every sleeping room However if there is a fuel burning appliance in more than one room and the number of apparatus is limited the following points should be considered when deciding where best to put the apparatus Locate the apparatus in a room containing a flueless openflued appliance and e Locate apparatus a room where the occupant s spend most time If the domestic premises is a bedsit a single room serving as both sitting and bedroom then the apparatus should be put as far from the cooking appliances as possible but near to where the person sleeps If the appliance is a room not normally used for example a boiler room the apparatus should be put just outside the room so that the alarm may be heard more easily Alternatively a remote alarm siren may be connected to a type A apparatus located in a room s containing a fuel burning appliance Where in the room should place the detector Apparatus located in the same room as a fuel burning appliance For both w
23. the fixing screws Step 2 Hold the Test Mode button down until the spanner icon appears in the bottom left hand corner of the screen and the bar graph scans from left to right This indicates the alarm is in sensor test mode where the sampling rate of the sensor has increased and the alarm can be tested using a known source of CO Step 3 Light an incense stick or cigarette using a match or lighter Extinguish the lighter or put out the match and place it into a dish of water Step 4 Hold the incense stick or burning cigarette 15cm 6 inches below the detector so that the smoke goes into the holes at the bottom of the detector As the smoke gets into the alarm the display will show the amount of CO being detected When the level of CO in the sensor reaches 50 the alarm will sound a single alarm cycle this confirms that the sensor is working correctly and is the end of the sensor test The alarm will return to normal standby mode Step 5 Put out the incense stick or cigarette by placing it into a dish of water Ensure that all flames have been extinguished NOTE If the level of CO in the sensor doesn t reach 50ppm then the Sensor Test mode will time out and finish automatically after 3 minutes Even if the level doesn t 11 reach 50ppm as long as the display shows a reading of CO then you can be confident that the alarm is working correctly If you have any questions about testing the sen
Download Pdf Manuals