Home
QUICK START GUIDE
Contents
1. STEP 3 CREATE THE USER Enter the details of the user you wish to set up for access to Arm and Disarm the alarm The email address you use cannot be the same as an email address already in use as a login to SafeDial Toolbox Select End User from the Drop Down box An entry table will appear Enter the following Serial Number of the unit Name of the premises i e home or office First Name Any Area Output 1 Then click Update User Last Name Email Mobile Phone Number PLEASE NOTE Password Only a Bureau Administrator the user that signed up Leave this field blank if you do not wishie is able to create manage Pocket Secure users Q Confirm Password Be sure that all information Is correct incorrect data can End User Serial Name cause malfunction Remember that a password must be 8 or more characters long with one digit and one uppercase character For more information and FAQ s on any of our products or services please visit us online at www globetelecom com au Level 8 499 St Kilda Road Melbourne VIC 3004 Email support globetelecom com au 1300 73 73 14 GLOBE TELECOM
2. GREEN PIN 4 R 1 RING WIRE YELLOW SET PRIMARY ALARM LINK PANEL INTERFACE TO ALARM PANEL INTERFACE TO SDW 100 INTERFACE TO SDI 10 DC POWER SDI 10 PSTN INTERFACE CONNECTIONS The SDI 10 PSTN port is an RJ 12 connector which terminates directing to the Public Switched Telephone Network PSTN This is typically wired in Mode 3 configuration which simply disconnects the normal line and gives priority to the alarm event The typical connections and pin outs of this connector are as follows PINOUT DESCRIPTION COLOUR PE N PE a E A PIN OE Bf SLACK T dh RED o A PING ea ce 2 OREN v PINS a ODE eae eee EON ee PIN 6 OPEN ALARM PSTN PANEL SETTING PRIMARY COMMUNICATIONS PSTN OR GSM GPRS The primary communications path is set by the jumper on the SDI 10 module e To set PSTN as the primary path remove the jumper e To set GSM GPRS as the primary path insert the jumper ALARM PANEL CONFIGURATION It is important that you disable PSTN line monitoring in the alarm panel If line monitoring is not disabled the panel will randomly report Telco Line Faults or Telco 1 Faults This is standard practice when using GPRS GSM units SafeDial Toolbox 7 key steps for activation and commissioning gt STEP 1 PRELIMINARY STEPS Fit the antenna and ensure all DC and interface cabling is completed Before applying power to the unit activation must be completed via the Safe
3. Dial Toolbox App gt STEP 2 INSTALLING THE SAFE DIAL TOOLBOX APP SCREEN 1 Go to www safedialtoolbox com au on your PC tablet or smartphone to arrive at the login portal Login using Email and Password sent with your order confirmation SafeDial gt STEP 3 ACTIVATION VIA YOUR SAFE DIAL TOOLBOX SCREEN 2 Once you have signed in you will be greeted with Screen 2 3 1 Select Activate Tab The first step in commissioning a SDW 100 unit is to activate the device Once you select the Activate tab you will be required to enter your product information 3 2 Enter Product Information SCREEN 3 e Enter the unit Serial number located on the inside of the SDW 100 e Enter your unique CMS customer Account code e Select the applicable 1345 phone number from the drop down list e Enter a Note to identify your Customer and Site details for easy identification in the future e Select Activate to complete the process gt STEP 4 CHECK LED INDICATIONS Successful power up and operation is indicated by the following LED patterns being displayed SDW 100 LED SUMMARY SDI 10 LED SUMMARY FOWER eee e E e eee ee eee a o i Pe eee er eee BLINKING DATA TRANSMISSION UNK h PUNANG ee ere SMB a OEE nn N SL E E E ee _B LOW BATTERY OFF l PANEL l BLINKING WHEN ALARM DIALS SIGNAL STRENGTH MED OR HIGH STEADY ON uua OFF HOOK OFF ON WHEN ALARM DIALS SERIAL l B
4. LINKING ime PANEL COMMS STEADY ON mn ONIN ad SE GPRS STEADY ON HEART B BLINKING REFER TO THE SAFE DIAL WIRELESS INSTALLATION AND USER MANUAL FOR DETAILED INFORMATION SeeRReeeE TERRE eeeceeoeneoe SDI 10 LED PANEL SDW 100 LED PANEL gt STEP 5 OPERATING AND TESTING 5 1 Ping Test SCREEN 4 After activation enter the unit s Serial number or your CMS Account number and then Ping the unit If the activation was successful SafeDial Toolbox will respond with the unit s configuration details 5 2 Unit Information SCREEN 5 The unit s settings and configuration details will be displayed by selecting the Information tab 5 3 Input Output Testing Selecting the Input Output I O tab will allow you to open close or pulse outputs check inputs and switch to PSTN communications for remote programming of the alarm panel For detailed instructions refer to the user manual 5 4 History The History tab shows all event transactions including input changes output changes unit registration PSTN switching etc All of which are time and date stamped Ave Boos Model 13 01 9813 01 16 Crtenos MCW Pocket Secure 3 easy steps for setting up your customers STEP 1 LOG INTO SAFE DIAL TOOLBOX Using your normal login log into SafeDial Toolbox STEP 2 PING THE UNIT Enter the Serial number of the unit you wish to access and Ping the unit Then click on Users
5. Sa feDial ae innovative always on security QUICK START GUIDE This guide provides step by step instructions with Em o simple explanations to get you up and running 3 For further information please refer to the SafeDial Wireless User Manual Installation and Connection Details 1 MOUNTING amp ENVIRONMENTAL CONSIDERATIONS 3 POWER SUPPLY REQUIREMENTS The SDW 100 should be mounted alongside the The SDW 100 and SDI 10 can be powered alarm panel in a clean and dry location protected from various means from water excessive dust extreme temperatures e Using the power supply provided recommended and direct sunlight The SDI 10 interface module e Using the alarm panel s power supply should be mounted inside the alarm panel enclosure e A combination of the above in order to comply with AS NZ2201 5 2008 Please refer to the diagram below Q 4 INTERFACE CONNECTIONS SDI 10 amp ALARM PANEL INTERFACE CONNECTIONS OMNI DIRECTIONAL Connections are required between the alarm panel ALARM PANEL OR DIRECTIONAL YOGI ANTENNA and the SDI 10 module as shown below The wire 3 omy o MAINS connected to the clock or data signal GREY is aur used as a watchdog feature to ensure the panel is still MOUNTED alive This feature should not be used with Tecom or IN ALARM a PANEL BOX Concept Panels If not used connect to ground or cut L a wire off at connector PHONE LINE Before applying power to the unit
6. connect the OPTIONAL REGULATED PLUG PACK i iri ONE teats eminal antenna and all interface wiring 2 naan ALARM PANEL BOX SAFE DIAL WIRELESS BOX ALARM PANEL CIRCUIT BOARD SDW 100 OUTLAY 1 i i i E x i i i i xfi i i H ZONE x i 1 i i xfi e ZONE x i Pai 3 a gt as gt A 1 1 i i al i 000000 WER f i N P u H T E oopggo z z 2 CONNECTING ANTENNAS too ton Tews th nt The direct mount antenna supplied will be suitable BE in most applications Where there is inadequate signal coverage as indicated by the front panel LEDs Low an external antenna should be used Always use good quality low loss feeder cable selected U o paume aa of according to the length of the cable run Ensure ppi All Maeteheveeaeeacepee all external connections are waterproofed using iii amalgamating tape i i spwc0 BATTERY SDW 100 AND SDI 10 INTERFACE CONNECTIONS There are four 4 wire connections between the SDW 100 and SDI 10 These are as follows COLOUR SDW 100 SDI 10 PANEL DIALLER INTERFACE CONNECTIONS The SDI 10 Panel Dialler port is an RJ 11 connector which terminates directly into the alarm panel s dialler port The connections and pin outs of this connector are as follows PINOUT DESCRIPTION COLOUR Meee WIRE nf SLACK 7 PIN 2 RING 48V INPUT LINE RED n T PIN Le OV INPUT LINE