1. Page 18 of 24 5th Driving wheel Control Unit 322 Fae gon gee I com ao Gon ENLI WOOT Page 19 of 24 5th Driving wheel Battery oN ese Pr aTa li Ml HH L 962 Page 20 of 24 5th Driving wheel Control handset Page 21 of 24 Page 22 of 24 LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Care and Health Comfort furniture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product t is also the responsibility of the LINAK customer to make a
2. gt MEDLINE CARELINE IMPROVING EFFICIENCY IMPROVING EFFICIENCY 5th Driving wheel kt To learn more about LINAK please visit D WWW LINAK COM WE IMPROVE YOUR LIFE Page 1 of 24 Page 2 of 24 Contents Preface o eee conn s ie aaron aetna a sea nt a eve apart EE AA A 4 Important information espousa creer we e a execu ase UA ean PU LA 5 The 5 Driving wheel system consists of the following products ccccccccceeeseseteeeeeeeteeeeseeeeees 5 System diagram 6 Connection of the 5 Driving wheel CB16 0 0cccccceccccecesssessseecsecsessesecseeseecsessessssesestsssesseeseeees 7 Connection of the 5 Driving wheel CB20 ccccccccceseeeseseseeeeseseseeeeseseeeeseseeeeeeseseeenseseseenseseieeees 8 Connection of the 5 Driving wheel CBGS 0 0 ccccccccccecesesceseescseseeseeseceeeecesseceesesseeeetssseeseeseeees 9 Explanation 0 Trooubleshooting Instruction 0 ccccccecccceccecceeeeeeeeeeeeeeeeseeeeeeeeeeseeeaeseeeeeesaesseesaeeaeseesaeeneesetseeseeeees 1 5 Driving wheel Control Unit styres r ne A EEE EEE E E a a 2 5 Drivirig wheel Battery saanane Sener Ww ea eee eee Neo eee 4 5 Driving wheel Control handset 0 0 0 ccc cece ceceseee cee eeeseeeseeseeeseesenseeeeeessneseesesesieeeseeenteeeneeee 5 Key to symbols aisa e EE O ANAE saan E AEE A ran aga areca ae 6 Labels isisa age i aes A RAA eee a A A 7 Drawing ADDS eich se cteeats Nearer d
3. LINAK UK Limited Ireland Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk MEXICO ILSA S A de C V Phone 52 55 53 88 39 60 Fax 52 55 53 88 39 66 E mail linak ilsamexico com www ilsamexico com PERU Percy Martin Del Aguila Ubillus Phone 51 99 88 39 879 RUSSIAN FEDERATION 000 FAM Phone 7 81 23 31 93 33 Fax 7 81 23 27 1454 E mail purchase fam drive ru www fam drive ru SINGAPORE Servo Dynamics Pte Ltd Phone 65 68 44 02 88 Fax 65 68 44 00 70 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC Phone 27 11 3122 292 or 27 11 20 77 600 Fax 27 113156 999 E mail gartht isagroup co za www isaza co za UNITED ARAB EMIRATES Mechatronics Phone 971 4 26 74 311 Fax 971 426 74 312 E mail mechtron emirates net ae www mechatronics ae SLOVAKIA LINAK Slovakia s r o Phone 421 51 75 63 414 Fax 4215175 63 410 E mail jp linak sk www linak com ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 53 30 802 Fax 81 45 53 30 803 E mail linak linak jp www linak jp MALAYSIA LINAK Actuators Sdn Bhd Phone 60 42 10 65 00 Fax 60 42 26 8901 E mail info linak asia com www linak my NETHERLANDS LINAK Actuator Systems B V Phone 31 765 42 44 40 Fax 3176 5426110 E mai
4. agnet active for longer than Enable by Magnet time out 5 HBDM Enable by Magnet Timer Error Wait until EBM is disabled If error is not removed then check HBDM All three battery indicators lashing 25 and 100 at slow flashing rate 50 at ast flashing rate Charger has detected overload condition Stopped Overload not charging Disconnect mains check battery connections Connect to mains until charged VPermanent has been lower than 34V for more than 30 seconds Stopped Low VPermanent not charging Remove load Stop movements of application Reconnect mains All three battery indicators lashing at slow flashing rate Mains not detected mains bit not active for 10 frames in a row Stopped Mains not detected not charging Remove mains wait 10 sec and reconnect EBM means Enable by Magnet Buzzer signal Trigger Error Mode Do the following One short beep When any key is activated while on attery and Enable by Magnet is not active Locked mode 1 Enable EBM and retry 2 Return CUDM to LINAK for service Failure on system to power down Power Down Error Three short beeps Battery Capacity less than 25 when the wheel is raised Low Battery Warning signal for low battery Connect to mains until fully charged One long beep the Power Switch Error bit in the Error Register is set one long beep sounds every time the
5. ein nia eau a RE ante ean nied 8 D claration of COM EMUILY osscssecscasser is E a a oa AAAA EE E EEE rae aed Manca aes 22 POG OSSOS nc uea i E EAA dayne ea ata aan EEA Ea EEE EA E a ROSE D 24 Page 3 of 24 Preface We are delighted that you have chosen a product from LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes controls and chargers This User Manual will tell you how to install use and maintain your LINAK equipment We are sure that your LINAK system will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK systems can affect their operation and durability The products are not to be opened by unauthorised personnel The User Manual has been written on the basis of our present technical knowledge We a
6. f Silent 40 80 Lit Lit Off Silent 80 100 Lit Lit Lit Silent Charging This is valid when charging mains or while being activated If disconnected from mains and no activation all LED s are off Speed LEDs When the 5 Driving wheel system is powered from battery the HBDM speed LEDs show the selected speed Configuration All software for the entire system is Quality Test released There will not be a Software task However there might be a configuration task depending on the existing system software n case of a configuration a template must be filled out and added to Further Specification in the System Specification for the CUDM The Template can be found on LINTRA f the addresses shown in the following are already in use in the existing system software where 5 Driving Wheel is to be used then a configuration is necessary In this case the CUDM must be created as a special item f OpenBus addresses can be used as shown in the following explanation no further software configuration is necessary Standard Configuration 25 50 100 These addresses must be checked to see if they are used by an existing system Check the CU CB software specification If these addresses are in LED4 LED3 LED2 use a new configuration must be described A oe S1 is defined as driving forward direction Standard address is H22 1 Gs S2 is defined as driving backwards Standard address is H23 TERN S3 Turtle is defined as d
7. ichael chen linak com tw www linak com tw TURKEY LINAK Ith Ihr San ve Tic A S Phone 90 31 24 72 63 38 Fax 9031 2472 66 35 E mail info linak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK LINAK LINAK A S reserve the right to make technical alterations Copyright LINAK 2013 02 MA M9 02 469 A WE IMPROVE YOUR LIFE
8. l info linak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 95 80 20 71 Fax 64 95 80 20 72 E mail nzsales linak com au www linak co nz NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Phone 45 73 15 15 15 Fax 45 74 45 90 10 E mail info linak com www linak com Page 24 of 24 USA LINAK U S Inc North and South American Headquarters Phone 1 50 22 53 55 95 Fax 1 50 22 53 55 96 E mail info linak us com www linak us com POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E mail dkreh linak dk www linak pl REPUBLIC OF KOREA LINAK Korea Ltd Phone 82 0 2 6231 1515 Fax 82 0 2 6231 1516 E mail scully linak kr www linak kr RUSSIAN FEDERATION 000 LINAK Phone 7 49 52 80 14 26 Fax 7 49 56 87 14 26 E mail info linak ru www linak ru SPAIN LINAK Actuadores S L u Phone 34 93 58 82 777 Fax 34 93 58 82 785 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 87 32 20 00 Fax 46 87 32 2050 E mail info linak se www linak se SWITZERLAND LINAK AG Phone 41 43 38 83 188 Fax 41 43 38 83 187 E mail info linak ch www linak ch Terms of use TAIWAN LINAK A S Taiwan Representative Office Phone 886 22 72 90 068 Fax 886 22 72 90 096 E mail m
9. l mark Recognised Component Mark Canadian Recognised Component Mark Recognised Component Mark for Canada and the United States T Mark RW T v approval Tuv Produkt Service TUVRheinland ETL C ETL File E97199 File E175209 File E151104 gt e gt O P4 aha A M Om Page 16 of 24 UL file number UL file number UL file number CSA PSE Mark Product with a thermofuse For indoor use House Safety isolating transformer Electronics scrap Equipment KI 2 Double square Patient part of type B Mand Patient part of type BF Earth protection Equipment class1 Earth CE Mark C TICK Labels for 5 Driving wheel UNAS e WE IMPROVE YOUR LIFE DESIGNED IN DENMARK N576 Type HBDM456VEA000 01 ite aye b Sw aoas V 1 0 Mr al fink ry FEM ZN NOT TO BE OPENED BY UNAUTHORIZED PERSONNEL m Porta har ao U Out 24 V Out 16 Amp OR CLT I NOT TO BE OPENED BY UNAUTHORIZED PERSONNEL CEC i P 0 1234567 0001 5 0 7654321 MADE BY LINAK A S DENMARK Nore tem CUDM00000A01062 Y Le ONLY OPENBUS SUPPLY 4 V max 312 V E e 2012 12 11 IPX6 t 2 A amp K DAA RN THT og AN NOT TO BE OPENED BY UNAUTHORIZED PERSONNEL CEO 3 P 0 1234567 0001 S 0 7654321 MADE BY LINAK A S DENMARK iaka Page 17 of 24 DRAWING APPENDIX 5th Driving wheel N e xp
10. nd supply a comprehensive user manual of the application LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for he application in question Page 23 of 24 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 75 58 61 06 656 Fax 86 75 58 61 06 990 E mail sales linak cn www linak cn SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 38 79 69 777 Fax 61 38 79 69 778 E mail sales linak com au www linak com au AUSTRIA LINAK Reprasentanz sterreich Wien Phone 43 1 890 74 46 Fax 43 1 890 74 46 15 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 92 30 01 09 Fax 32 0 92 30 88 80 E mail info linak be www linak be BRAZIL LINAK Do Brasil Com rcio De Atuadores Ltda Phone 55 11 28 32 70 70 Fax 55 11 28 32 70 60 E mail info linak com br www linak com br CANADA LINAK Canada Inc Phone 1 50 22 53 55 95 Fax 141 62 55 77 20 E mail info linak ca www linak us com CZECH REPUBLIC LINAK C amp S S R O Phone 420 58 17 41 814 Fax 420 58 17 02 452 E mail ponizil linak cz www linak z DISTRIBUTORS ARGENTINA Novotec Argentina SRL Phone 54 11 4303 8900 89 Fax 54 11 4032 0184 E mail info novotecargentina com www
11. novotecargentina com AUSTRALIA Ballarat Industrial Supplies www ballind com au BL Shipways amp Co www blshipway com au Gas Strut Marine and Industrial www gasstrutmarine com au Prime Motion amp Control www primehyd com au West Vic Industrial Supplies www westvicindustrial com au COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA Pt Himalaya Everest Jaya Phone 62 21 54 48 956 65 Fax 6221 61 94 658 1925 E mail hejplastic div centrin net id www hej co id IRAN Bod Inc Phone 98 21 88 99 86 35 6 Fax 98 21 88 95 44 81 E mail info bod ir www bod ir DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 74 45 80 48 Fax Sales 45 73 15 16 13 E mail info linak com www linak com DENMARK LINAK Danmark A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 84 18 700 Fax 358 10 84 18 729 E mail linak linak fi www linak fi FRANCE LINAK France E U R L Phone 33 0 2 41 36 34 34 Fax 33 0 2 41 36 35 00 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 60 43 96 55 0 Fax 49 60 43 96 55 60 E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 91 12 04 39 33 35 Fax 91 12 04 27 37 08 E mail info linak in www linak in IRELAND
12. nts in the wrong sequence may damage the equipment Please follow the instruction strictly 1 Make sure that the CB20 is NOT connected to mains 2 Connect cable 0964519 to the wheel 3 Connect cable 0964519 to the CUDM The connector with yellow O ring in port Out 1 and the connector with green O ring in port Out 2 4 Connect cable 0964525 between BADM and CUDM port Out 3 5 Connect cable 0964526 to CUDM port In1 and CU20 port Out 7 Connect HBDM to CU20 In 1 Connect mains cable Insert blind plugs in unused connectors and click cable locks on CUDM and CB20 Before use charge the system for at least 1 hour COND Page 8 of 24 Connection of the 5 Driving wheel CB6S E Important Connection of the components in the wrong sequence may damage the equipment Please follow the instructions strictly If CB6S is used the charging will take place via the normal OpenBus connection a standard cable W RO45 6 wires modular Jack with plugs in both ends is connected to CB6S via a MJB Follow steps 1 to 4 in the previous descriptions Disconnection of the 5 Driving wheel If not connected to mains connect the system to mains for at least 10 seconds Disconnect mains and remove mains cable Wait at least 30 seconds Remove cable between CUDM and CU20 Disconnect HBDM Remove cable between wheel and CUDM Remove cable between Battery and CUDM Oy a Connection
13. of IB30 service tool i Important Connection of the components in the wrong sequence may damage the equipment 9 Please follow the instructions strictly If not connected to mains connect the system to mains for at least 10 seconds Disconnect mains and wait at least 30 seconds Connect the IB30 to CU20 port In 2 Connect to mains Connect the IB30 to the PC USB cable a Se Disconnection of IB30 service tool i Important Disconnection of the components in the wrong sequence may damage the equipment 1 Please follow the instructions strictly 1 Remove the USB cable from the PC and IB30 2 Disconnect the IB30 from CU20 port In 2 Page 9 of 24 Explanation Battery level When the bed is connected to mains the battery indicators will be lit When the batteries are fully charged all 3 battery indicators will be lit in cases where the 25 indicator is lit the bed should be charged As the batteries are being discharged the indicators will gradually turn off Arrow Up Drive Forward Arrow Down Drive backwards Hare Drive fast When this function is chosen it s indicator will be lit Turtle Drive slow The system is set up in such a way that it always starts driving slowly The turtle indicator will therefore always be lit at start up Activation button For activation of the panel touch the raised area lowest on the handset with the magnet shown in the photo below It is recommended to test the D
14. procedure Must be followed in order to secure no potential power errors No mains connected Mount cable on the wheel Mount wheel cable in CUDM yellow ring to the left side ch 1 green to the right side ch 2 as shown on next pages Mount CUDM battery cable Connect CUDM to power from CU20 channel 7 Connect HBDM to existing OpenBus system Connect to mains and charge to 100 Page 6 of 24 Connection of the 5 Driving wheel CB16 Important Connections of the components in the wrong sequence may damage the equipment Please follow the instructions strictly As the system is powered by battery it can be unintentionally powered up and create hot plugging STEP 1 Make sure that the CB16 is NOT connected to mains STEP 2 Connect cable 0964519 to the wheel see below STEP 3 Connect cable 0964519 to the CUDM The connector with yellow O ring in port Out 1 and the connector with green O ring in port Out 2 Cable connects to CB16 STEP 4 Connect cable 0964525 between BADIMKand CUDM port Out 3 STEP 5 Connect cable 0964526 to CUDM port In1 and CB16 port 6 STEP 6 Connect HBDM to CB16 A STEP 7 Connect mains cable STEP 8 Insert blind plugs in unused CUDM connector ports and fasten cable locks on CUDM and CB16 STEP 9 Before use charge the system for at least 1 hour Page 7 of 24 Connection of the 5th Driving wheel CB20 9 Important Connections of the compone
15. re constantly working on updating the information and we therefore reserve the right to carry out technical modifications LINAK A S Page 4 of 24 Important information For further information regarding Warnings and Recommandations please read the user manual Actuators and Electronics on our website www linak com The 5 Driving wheel system consists of the following products Driving wheel see page 7 e in partnership with TENTE Driving wheel must be ordered from Tente Control Unit see page 12 e CUDM e Compatible with CB16 CB20 and CB6S control boxes and LINAK controls Battery see page 14 e BADM 2 9 Ah Control handset see page 15 e Special handset e Special activation key e Compatible with CB16 CB20 and CB6S control boxes Usage e Compatibility CB16 CB20 and CB6S longer charging time e Duty cycle Continuous use on fully charged battery e Usage temperature 5 C to 40 C e Relative humidity 20 to 80 at 30 C e Storage temperature 10 C to 50 C e Atmospheric pressure 700 to 1060 hPa e Approvals Pending Page 5 of 24 System diagram J90000 HBDM To existing CB20 CB16 CB6S system e CB20 with channel 7 option e CB16 with channel X option e CB6S with MJB 0858008 Magnet CUDMO00000A01062 BADM16 0100 0000 0964526 2000 0964525 280 0964519 1500 0 Do not use spare OpenBus ports on CUDM for other purposes insert blind plugs Assembly
16. rive Me system before driving with a patient INSTRUCTIONS 1 Activate panel with magnet LED above Turtle will illuminate 2 Choose other speed if desired 3 4 After the transportation is completed the bed must be connected to mains for battery charging Activate by the use of arrow buttons for desired driving direction Be aware of 1 2 3 Wheel lowers automatically and starts driving at once when an arrow button is activated only if the panel has been activated Wheel raises automatically approx 5 seconds after end of driving The panel will be active for approx 10 seconds after the wheel has been raised after which all indicators will turn off During connection of mains the panel cannot be activated and drive functions are therefore not available Do not move the bed from side to side before the wheel has been raised from the floor Page 10 of 24 Troubleshooting Instruction ERROR MODE LED signal Trigger Error Mode Do the following The two speed LEDs flashing at fast flashing rate for 3 seconds Activation of Enable by Magnet sensor when connected to mains Drive lockout Remove connection from mains and retry The two speed LEDs flashing at fast flashing rate Activation of both direction keys HBDM Key Error Wait until EBM is disabled If error is not removed then check HBDM keys The two speed LEDs flashing at slow flashing rate HBDM keeps Enable by M
17. riving slowly Standard address is H24 s2 LEDS a i LED1 S4 Rabbit is defined as driving fast Standard address is H25 Page 13 of 24 5 Driving wheel Battery The battery supplies power to the CUDM The battery charge state is monitored in the CUDM and is displayed in the handset HBDM Features and Options e Battery capacity 2 9 Ah e Input voltage 24V e Capacity monitoring via handset or Service data e Colour Light grey RAL7035 e Plug type Mini fit turned 80 e Charging via CUDM e Power supply no external power supply available e IP rating IPx6 Usage e Compatibility CUDM only e Duty cycle Continuous use e Usage temperature 5 C to 40 C e Relative humidity 205 to 80 at 30 C e Storage temperature 10 C to 50 C e Atmospheric pressure 700 to 1060 hPa e Approvals Pending e Internal fuse 10A Charging time via CB16 CB20 approx 8 hours T Charging time via an MJB CB6OBM CB6OBF gt 25 hours Only to be charged via CUDM Page 14 of 24 5th Driving wheel Control handset The handset is specially designed for control of the 5 Driving wheel It is an intuitive handset which is easy to use the handset has arrow heads for moving forward or backwards To control the speed of the 5 Drive wheel it is only necessary to press one button If the rabbit button is pressed the system will go into fast mode if the turtle button is pressed the system will drive at a lower
18. s System is ready for use 5th Driving wheel Control Unit CUDM is the Control Unit for the Driving Wheel system This is where communication between the battery handset and wheel takes place The Control unit comprises of two channels for controlling motors One channel CH1 is dedicated to the Wheel Motor and the other CH2 is dedicated to the Wheel Lowering Motor CUDM includes 1 pcs 0770021 A Microfit Blind Plug 2 pcs 0770022 A Minifit Blind Plug 1 pcs 0951027 A Retainer Features and Options e Softstart and softstop Yes e Colour Light grey RAL7035 e Plug type OpenBus plug Battery input ch 3 rotated 180 e Charging via OpenBus e Power supply BADM Battery box Usage e Compatibility CB20 CB16OBF CB16OBL CB6OBF and CB6OBM e Duty cycle Driving motor continuous e Duty cycle Wheel lowering motor 2 18 2 minutes continuous use followed by 18 min not in use e Usage temperature 5 C to 40 C e Storage temperature 10 C to 50 C e Relative humidity 20 to 80 at 30 C e Atmospheric pressure 700 to 1060 hPa e Approvals Pending Page 12 of 24 Battery indicators anagement of HBDM Battery Charge State LED s The HBDM battery charge state LED s are controlled as follows Battery LED percentage 3 s 7 Buzzer remaining 25 50 100 0 10 Flashing fast off off According to Table 2 see later page when the wheel is raised 10 40 Lit Off Of
19. speed which is suitable for maneuvering the bed in small places or around sharp and difficult corners Features and Options e max 4 buttons e max 5 LED s e Customised design possible e Colour light grey RAL7035 e Integrated cable with OpenBus plug e IP rating IPx6 Usage e Compatibility CUDM 5 Drive wheel system e Duty cycle Continuous use e Usage temperature 5 C to 40 C e Relative humidity 205 to 80 at 30 C e Storage temperature 10 C to 50 C e Atmospheric pressure 700 to 1060 hPa e Approvals Pending Functional description The operating surface consists of 4 keys 5 LED s and a 25 50 100 hidden magnet activation key EE Keys PETN Arrow pointing upwards Drive forward s Arrow pointing downwards Drive backwards SO Hare Fast speed Tortoise Low speed Sites 4 LED5 LED1 Magnet activation Ss Must be activated in order to use the system LINAK LED s 25 50 100 Indicates battery capacity Hare LED lit when fast speed chosen Tortoise LED lit when slow speed chosen Page 15 of 24 Key to symbols The following symbols are used on the label on the LINAK products APPROVAL V94265 APPROVAL NO 97122 Tuy Rheinland Gruppe BAUART GEPRUFT TYPE APPROVED TUV Bauart gepr rt PRODUCT SERVICE CS95145V LGA WI s Demko approval Fimko approval Australian approval mark Australian approva
20. user activates a direction key Power Switch Error Connect to mains and disconnect Try again If problem persists return CUDM to LINAK Five long beeps Temperature FET exceeds FET Temperature Limit FET Temperature Exceeded Return item to LINAK Three long beeps he wheel connected input is short circuited Wheel failure Wheel Up Switch failed to Wheel Up Switch failure 1 Check all connections are in place 2 Exchange wheel cable and or wheel 3 Exchange CUDM Wheel goes down and immediately up again The CUDM has detected low attery state No further running allowed Charge battery Connect to mains Information regarding resetting the HBDM in case it is already configured to another CUDM 1 S1 amp S2 10 seconds including mains on Hereafter mains off wait 5 seconds mains on again 10 seconds hereafter OK this is called a power cycle 2 S3 S4 10 sec LED flashes release button gt HB 2 uP er Reset of configuration e g if HBDM has been exchanged a b Make sure the system is powered from mains Press and keep pressed both the Hare and the Turtle keys S3 and S4 until all LEDs start flashing at a fast rate will happen after 10 seconds Page 11 of 24 Release the keys and the CUDM will reconfigure all system components When configuration is done the LEDs will stop flashing and return to showing the level of battery charge Disconnect main