Home
KAPTOR MULTI - BM Tecnologie
Contents
1. TECNOLOGIE INDUSTRIALI With KAPTOR MULTI B M Tecnologie Industriali developed and introduced in water flow Measurement Market the first multi purpose Data Logger for measurement in full pipes and open channels KAPTOR MULTI is a Data Logger developed for measuring in water networks aqueducts and sewerages Depending on the applications it can be equipped with the module TTFM KAPTOR or OCM KAPTOR The two different modules combined together with the analog and digital inputs of KAPTOR MULTI can acquire pressure level and flow from external sensors units to suit every application in water market KAPTOR MULTI has a rechargeable battery LiIFePOH4 38 Ah lasting up to one year and it can be powered by a universal mains too It acquires data on an internal 4 Mb memory and on an external 4Gb SD Card the acquired data together with the diagnostics signals can be remotely transmitted through a built in GSM GPRS modem The IP68 protection grade of the Data Logger unit and of its modules complete the excellent performances of this device The advanced configuration menu can guide in a few steps through a display and a keypad even a few experienced operator on about how to use KAPTOR MULTI A sophisticated diagnostic system with a smart user interface allows the user to understand quickly if the measurement is correct and if not to identify what the problems are The Data Logger includes the software HydroFlux developed for the
2. COMPLIANCE STANDARDS C Compatibility Electromagnetic EN 61326 1 2006 05 Immunity ETSI EN 301 489 17 V1 2 1 FLOW RATE ULTRASONIC MODULE TTFM KAPTOR Performances INTERFACE RS485 ModBus standard Carbon steel Stainless Steel Cast Iron Ductile Iron Copper PVC Aluminum Concrete Fiberglass and many other materials The flow can be measured on pipes with an inner lining by selecting the liner material and thickness in a dedicate menu Internal diameter Up DN15 to DN6000 mm The upstream straight section must be greater than 10 diameters the Hydraulic conditions downstream section greater than 5 diameters MEASURABLE FLUIDS Thee Drinking water sea water kerosene gasoline fuel oil oil propane Accuracy 1 0 dopo taratura Linearity 0 5 Ripeteability 0 2 0 5 Materials 45 C butane 0 C any liquid that spreads ultrasounds Suspended Solids Up to 20000 ppm mg l with a few air bubbles TYPE TYPE OF ULTRASONIC TRANSITE TIME SENSORS ULTRASONIC TRANSITE TIME SENSORS DN50 2000 and pipe thickness 100 mm Type Temp 20 C 130 C Vel Max 16mt sec Press Max 20 Bar Mounting methods N W pipes DN lt 32 mm Clamp on standard external pipe s nie EN E mm e TS2 NG KAPTOR for DN15 100 mm with work frequency 1 5 MHz e TM1 NG KAPTOR for DN50 1000 mm with work frequency 1 MHz e TL1 NG KAPTOR for DN300 6000 mm with
3. IP68 Cable length 5m Mounting Kit with chains for a fast clamp on sensors installation For pipes up to 1 mt diameter RC 20 2 Waterproof Paper Roll for Z type mounting of clamp on sensors Wieght 0 3 Kg Height 0 3 m Length 20 m B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it TECNOLOGIE INDUSTRIALI Equipment OCM KAPTOR BASIC EQUIPMENT Quantity Description OCM KAPTOR SENSOR Doppler Flow Meter module for open channels Wedge sensor with built in level measurement Interface RS485 Power Supply 8 24V Mounting Collar for pipes DN200 800 B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it TECNOLOGIE INDUSTRIALI HDROFLUX Software Features HydroFlux is a software developed by B M Tecnologie Industriali for the configuration and advanced data management of KAPTOR MULTI It is part of the standard supply of KAPTOR MULTI With HydroFlux it is possible to set all the parameters by using the user interface and a laptop PC connected to KAPTOR MULTI It is possible to enter the users receiving alarms select the plant and the DMA s name set up the data pima transmis
4. advanced management of the acquired information it allows the creation of master data tables and graphs it imports and exports them KAPTOR murr iS compatible with hydraulic softwares Waterguard and Channelguard KAPTOR mutt MULTI PURPOSE DATALOGGER FOR MEASUREMENT IN FULL PIPES AND OPEN CHANNEL Long life battery system of measurement acquisition and transmission of flow for water network and sewerages FLOW RATE MODULES FOR KAPTOR murt TTFM KAPTOR module is the Ultrasonic Flow Meter using clamp on external sensors or insertion sensors for flow measurement OCM KAPTOR is the Doppler Flow Meter module using wedge sensors on Open Channels and insertion sensors on full or part filled pipes Main Features Main Applications S A SNS SN S YL NNN NNN s XS NS SN Flow measurement in full channels TTFM KAPTOR Ultrasonic Technology OCM KAPTOR Doppler Technology Protection Grade IP68 Battery life up to 1 year expandable Compact and easy to install Digital and analog inputs for external sensors Data acquisition on internal memory and SD Card Data transmission to a remote system via GPRS Software HydroFlux for data management and configuration pipes and open Search for Water Losses in Acqueduct Search for Extraneous Waters in sewerages DMAs District Metered Areas Check of fire system Calibration of Numerical Models Measurement campaigns on Long and Short Periods
5. el aa eee ty en ay cee ae 06 06 12 06 06 14 06 06 16 06 06 18 06 06 20 06 06 22 07 06 00 07 06 02 07 06 04 07 06 06 07 06 08 07 06 10 06 06 11 10 59 k lt lt gt gt gt 07 06 11 10 59 O Threshold Ti Last but not least it is possible to set up general parameters such as analog inputs calibration or read set and delete DMAs and measuring stations from the in internal memory of the device B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it TECNOLOGIE INDUSTRIALI WATERGUARD Software Features KAPTOR wmuLtTrI is compatible with the hydraulic software WATERGUARD for water losses management in water networks WATERGUARD is an basic tool for DMAs District Metered Areas by using pressure and flow rate measurements to manage and reduce water losses in water networks WATERGUARD receives signals sent by any measuring device of flow rate pressure power absorption power consumption any signal related to an electrical impulse by GPRS GSM technologies Data are analyzed and validated in this way the user can optimize the management of the water network and choose how to act to reduce water losses and for example the power consumption of pumping stations The system is based on the data collection from the measuring devices by using Data Loggers with GPRS GSM mo
6. in Aqueduct and Sewerages Water Balance Pumping Station Control Waste Water Treatment Plants Hydroeletric Power Stations Industrial Processes Monitoring B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it TECNOLOGIE INDUSTRIALI Technical features DALOGGER KAPTOR mur O Da n tok lt a Digital Inputs Serial Port RS232 RS485 port with mains supply POWER SUPPLY Internal Battery 4 digital inputs opto isolated for water meters For programming firmware update and data download For TTFM KAPTOR e OCM KAPTOR LiFePOH da 38Ah rechargeable Low tension 11 24Vacjpc High tension by AC DC converter 90 240Vac 60 50Hz Up to 2 rechargeable external batteries 38 Ah each Max in transmission 200mA 13 2V Min in low power 0 39mA 13 2V External Power Supply External Battery Consumption V O a a Q o g 2 S lt gt T x5 eJ 3 23 o B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it TECNOLOGIE INDUSTRIALI MECHANICAL Black Case Case Material PAGE loaded Dimensions and weight A A ee Ie g 10 Kg batteries included
7. are enhanced or new ones are built etc LL ie ALLLELIEEEI TPES ESBS Elm atlitadte tr Unsteady hydraulic calculation an essential approach to simulate the real behaviour of the drainage systems Analysis of the flooding events The water when it goes out the collecting system is represented by a bi dimensional module taking into account the position of the soil the obstacles etc Simulations of complex handmade objects spillways siphons lifting storage tanks etc The calculation is possible even for wide networks Drawing of the inputs of groundwater in the sewer network B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it
8. cal compatibility with the pipe or sensors YP materials with a minimum amount of 100 ppm suspended solids gt 0 06 mm i Max 0 75 full range INTERFACE MECHANICAL Dimensions and weight 4 Kg with 30 cable U oF U m my B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it BM TECNOLOGIE INDUSTRIALI Equipment KAPTORmurm BASIC EQUIPMENT KAPTORwuit1 Data Logger for pipes and open channel measurements Rechargeable batteries 38 Ah SD Card RS232 Modem GPRS Internal Memory 262144 records 2 AI 4 DI ANTENNA KAPTOR Multi band Antenna IP68 pre connected IP68 1 5 mt cable HydroFlux Software for configuration and data management 1 EXTRA BATTERY PACK Input 110 240VAC with IP68 connector TTFM KAPTOR BASIC EQUIPMENT Quanta eseription OOOO TTFM KAPTOR Ultrasonic transit time Flow Meter module for full pipes 1 1 1 SD Card 4 GB 1 1 Interface RS485 Power supply 8 24V Input for clamp on or insertion sensors Box IP68 TS2 NG KAPTOR Pair of clamp on transit time sensors For pipes DN15 100 Temp 20 C 80 C Max Speed 16mt sec IP68 Cable length 5m TM1 NG KAPTOR Pair of clamp on transit time sensors For pipes DN50 1000 Temp 20 C 80 C Max Speed 16mt sec
9. dem Data are collected and remotely sent to a server located in the customer s facilities or in the web farm of BM TECNOLOGIE INDUSTRIALI i A SCHEMA FUNZIONALE DEL Incoming data RAW DATA are saved and MONITORAGGIO classified in an Oracle data base A copy of the EIEH NY raw data is always saved in the system Then i N A Fi Utente Ery u 2 gt e a EI raw data are analyzed to check if they are R SNN aL continuative suitable and if there are errors or Utente 2 Utente 3 a A De in aa a troubles After this first check they are Ra x o f processed by default o by rules defined by the TE et i operator The system is opened so new rules can be defined by the user in any moment in a S dedicated WATERGUARD window When data Centro di controllo are elaborated or validated they are saved in nn aa an Oracle data base as it happened for the raw data WATERGUARD is an user friendly software and is composed of windows to help the operator It has a GIS system too it is possible to upload all the information about the water network features and the installed devices in a geographical reference B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it TECNOLOGIE INDUSTRIALI CHANNELGUARD Software Features KAPTOR M
10. sion the sampling time and _ Data Ora Tipo misura Valore logger parameters etc b 02707 2011 17 46 00 a o oo o a Elabora dati grezzi 02 07 2011 17 46 00 TT 0 00 Hyd roFlux can create measuring 02707 2011 17 46 00 VBatt 15 90 z i i 02707 2011 17 46 00 P 0 000 apin stations to link the data downloaded 02 07 2011 17 47 00 P 0 000 02 07 2011 17 47 00 q 0 00 from a KAPTOR MULTI Data can be eae TT 0 00 02707 2011 17 47 00 WBatl 15 90 processed to be displayed in diagrams 02707 2011 17 47 00 P 0 000 02 07 2011 17 47 00 a 0 00 and charts in this way their trends could Saree IT oT b 02707 2011 17 47 00 VBat 1590 cameo e easily checked and data could be f imposta periodo E a A easily transferred Data Inizio Data Fine iorna With HydroFlux data can be giu 2011 ou gt fron giu 2011 ou gt Jon m downloaded from the internal memory of KAPTOR MULTI with the serial port or with a USB Pen Drive It is possible to select the time interval for Pressione e and the data to be displayed Pressure Flow TOM TOS With HydroFlux the user can configure Pin Wal hi a yi i ant I KAPTOR MULTI by using a PC GPRS i a Ul KIS Nahi attic variables to allow the device a remote ae data Cana on to a web portal and A DataLogging configuration for serial po S TAN y connection p ff S pe nl ae a Lae a ea ee ne el or a an lt a es a ae Pa an
11. uLTI is compatible with the hydraulic software CHANNEL GUARD for the analysis of sewer networks This software receives and saves the data sent from the measuring points using an Oracle data base After receiving the data the software checks and validates them reporting any error Validation is based on threshold values respecting the flow rate curves of the measuring point and any validation procedure the Water Company needs as it is a free software Everything is supported by a GIS system that besides a geo reference of all the data allows an easy management of the cartographic elements The software has a historical recording of the data It allows to manage raw data sent by the monitoring devices treated validated and historical data Channel Guard besides giving the flow rate and volume values of each single measuring point permits to create water balances considering the different concentration times The software can also manage the data coming from rain gauges in order to correlate weather events and flooding that could happen in the sewer networks Numerical models if correctly calibrated with the sewer flow rate measurements will be able to verify the behaviour of the sewer network in case of anomalies or floods and to test the sewer network if new parts are going to be built if spillways are a going to be set or closed if rain water storage tanks or flywheels are used if existing pumping stations
12. work frequency 0 6 MHz Temp 20 C 90 C Vel Max 16mt sec Clamp on for high temperature applications external pipe s surface e S1 HT KAPTOR per DN15 150 mm e M1 HT KAPTOR per DN50 700 mm Temp 30 C 160 C Vel Max 16mt sec Insertion type e B 45 1 NG 1 KAPTOR DN50 2000 and pipe thickness lt 100 mm e B 45 2 NG 1 KAPTOR B M Tecnologie Industriali S r l Via Praimbole 13 3510 LIMENA PD ITALY P I V A e C F 02459940280 Tel 049 8841651 Fax 049 8841654 e mail info bmtecnologie it web www bmtecnologie it BM TECNOLOGIE INDUSTRIALI V pipes DN40 800 mm Z per tubazioni con DN 300 mm Cable lenght 5 m extendable with 5 m extensions Max 200 m Protection Grade IP68 MEASURING UNITS m3 USGal UKGal millionUSGal cubic feet barrels oil US barrels oil Metrical Imperial etrical Imperia UK sec min hours days OUTPUTS Current Active Current Loop 4 20mA 100 Q 12 VDC OCT Output freq Open Collector 12 9999 Hz o allarms Releys Output Relay 1A 125VAC or 2A 30VDC for totalizer pulse alarm FLOW RATE DOPPLER MODULE OCM KAPTOR TYPE OF SENSORS AND APPLICATIONS Installation on the channel bottom Suitable for Open Channels with regular or Wedge sensors irregular shape small or medium Insertion sensors Installation on every kind of pipe of any material or diameter MEASURABLE FLUIDS ae Water or any other fluid with chemi
Download Pdf Manuals
Related Search
Related Contents
TI2000-054 Step Down Transformer Data Projector Istruzioni per l`uso メール配信登録の流れ(520146Byte) BC-1020 - ServiCenter 2011 Nissan Service and Maintenance Guide Copyright © All rights reserved.