Home
User Manual of LCD-show Alarm System
Contents
1. When it meets alarm it will cut the talking and ensure alarm information comes first Have in built backup battery and can continue to work and last for 8 10 hours when electricity is cut or in failure How Do I install the alarm system I Installation of Main panel a Insert the siren to the port of main panel and connect telephone line with the port of Line and Phone with the telephone set That is to say the telephone must be connected with main panel The telephone can work normally b Power the system on and switch it to ON the power status will be blinking and sound beep which shows the main panel works normally It will sound three beep beep beep every 30 seconds which helps users remind of setting alarm phone numbers The sound beep will disappear when you finish the alarm phone number setting Please press 4 to make the system disarmed to avoid it activate the siren to alarm when registering sensors Attention a Try to install the main panel in the center of defense zone and pull antenna and make it up for getting more wireless receiving distance b Installation position should be far away with huge metal objects and wireless device c Connect the trunk line with main panel in order that it can dial out in the first second when there is an alarm d Should be installed in a shelter II Installation of door sensors Door sensors are used for detecting the status of open and
2. Record Replay Delete Register message The all stored sensors message with main inform 38 the Ist phone number of ation panel monitoring center 39 the 2nd phone number of monitoring center There are six defense zones so you can install sensors in any of defense zone You will know what sensors are triggered from the screen of main panel You can input OX and then trigger sensors and then enter into the this defense zone For example if you want to code the detectors and sensors into the 2 or 4 desense Zone 2 Enter 02 and trigger sensors Zone 4 Enter 04 and trigger sensors V How to Modify passwords Command 10 passwords passwords must be 4 digitals such as 2345 This password is used for remote control Users should setup it confidently VI Defense Zone Setting You can set your sensors or detectors into a special defense zone which can let some detectors not work when there is an alarm Command Zone No 2 X X is zone type such as 0 for Closed Zone It is closed temporarily and is used for arming in sub defense zone 1 for Immediate Zone It can activate the siren and order the main panel to dial out Alarm phones immediately if the detectors in this defense zone detect some unwonted Status 2 for Delay Zone Activate siren and dial out in 30 seconds when detectors in this zone find something unwonted 3 for Urgen
3. close of windows and doors It will detect it and send the signal to main panel Fix the transmitter box and magnet to door case and door You d better fix it again with bolt if you want it fixed strongly Caution A Magnet should be close to signal status and make the transmitter box and magnet as close as possible lt 10mm B In order to get the best receiving distance you should pull the antenna and make it upwards C If the indicator light of door sensor are still blinking it shows battery fails So please replace it as soon as possible III Installation of Wireless PIR motion Sensors PIR Sensors are used for detecting if someone moves within in a certain place Fix it on the wall 2 2 2meters high and you should adjust the position to make it face to the defense zone Caution How Can I set up the main panel Before any operation please enter passwords and Default is 1234 Two beeps show that the operation is successful four short beeps shows fails You have to try again in this case Please press to exist the programmed status System will exist automatically if there is no any order within 30 seconds 1 Record alarm message Input 6 to record message within in 10 seconds and you will hear a beep It will exist with two beeps automatically after 10 seconds Every recorded message will replace the last message The message should be short and clear For example This is xxxxx building and room xxx please come
4. Wireless Auto dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product please read this user manual thoroughly before using it Features and Function 1 10 11 12 Anti interfere function When someone interferes it with same frequency the main panel will activate siren to alarm Support anti decode of remote control and it can shield the disarm signal if needed 6 programmable Defense zone available with status LED The main panel can register 99 wireless detectors sensors Every defense zone can set independently arm disarm time delay alarm and so on Have the function of one key arm User can start Home arm or Out arm freely by keeping pressing one key on remote control Can set the reminder sound of defense zones Will remind users of remembering to arm the system when leaving the house Can be compatible with other products of our company Such as wireless big outdoor siren and mini siren It stores 2 groups of monitoring center and 6 groups of user phone numbers to dial out and play the recorded message if there is an alarm Can arm disarm with remote control or keypad on the main panel Can arm disarm listen in by calling the host phone number The phone numbers of main panel Have the function of reminder for circuitry failure For example if telephone line is cut or short the main panel will alarm Have the superior of calling out
5. e system to make the host arm or disarm by input passwords If the password is correct the system will sound beep two times If wrong it sounds beep four times And then you can control the system with following command Press 1 to arm Make sensors working Press 2 to disarm make sensors stop working Press to enter into the mode of 30 seconds of listen in Press to exist Note The system will hang off automatically if passwords are wrong for 5 times or no any order in 20 seconds The Use of Electronic Clock ADJ Adjust To shift time and date to change the data SET Enter exit the setting of Date amp Time Procedure Use a needle or something shaped like stitch or injection to do the following steps Press SET for two times to set the month you can press ADJ to adjust the month After that press SET again to be in the date and time setting condition After setting press SET and ADJ for one time to finish Standard pack components E main panel 1 pcs E wireless PIR detector 1 pcs E wireless door sensor 1 pcs E Min siren 1 pcs E remote controllers 2 pes E 12v DC adapter 1 pcs E instruction manual 1 pcs The following sensors can be optional Signal Repeater Glass Sensor Wireless Smoke Detector Wireless keypad Panic Button Gas Detector Wireless Outdoor Siren with flash o a Remote Controller Wireless Pet Immune PIR Detect
6. ed code Check the code again Notice mDon t install the system beside the strongly disturbing equipments like motor computer etc mShould be installed in a concealed place Don t mis plug the out line and telephone line of the phone mShould be plug firmly and ensure well dissipation mOnly designed for indoor
7. ller Power Supply DC12V inner DC12V battery Static Current 0 Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Working Condition Temperature 10 C 40 C Humidity lt 90 FAQ Symptoms Causes Remedies Cannot alarm by phone 1 Hasn t armed 2 Less than 30 seconds after arming 3 Set wrong phone num 4 The two parts of door window sensor is installed too far from each other 5 Haven t activated PIR 6 Hasn t checked code 1 Make arming 2 Operate after 30 seconds 3 Set the num again according to the manual 4 Adjust the installation place of the door sensor Activate the PIR Check code again ou Remote controlling distance is too short and the light indicator is not on strong enough 1 The battery of remote controller rustily 2 Low battery Clean the rust Change battery po the alarm panel always makes beep voice 1 donot Connect telephone line to main panel 2 donot setup user number 3 donot record 10s voice message 1 Connect telephone line to main panel 2 setup user number 3 record 10s voice message Light indicator of door sensor and PIR is always on Low battery Change battery Dial alarm num slowly The main panel has stored others num Set it again according to the operation manual The main panel cannot receive accessories signals Hasn t check
8. lose 17 0 8 Start close the function of anti decode In order to Prevent someone from decoding the alarm system we often start this function Once starting this option the signal from remote control is screened and only the keypad in the main panel can arm the system Command Start 18 1 Close 18 0 9 Start close the reminder for phone line trouble It will tell you when the phone line is cut or short It will sound beep three times every 10 minutes Command Start 22 1 Close 22 0 10 Setup the times of ring If you want to remote control the main panel you can set the ringing times of the calling the times canbe 00 12 For example if you set the times into 04 then when you dial the number of the main panel it will automatically get through after you hearing 4 times of the ringing 00 means the host will not get through Command 12 XX XX shows times of ring from 00 12 11 Setup the time of siren You can setup the siren to make it last 5 minutes 10 minutes or 30 mins Command 29 XX XX is 00 30minutes 13 Start close the reminder of arm disarm system User can do start it if he wants to siren to make sound when he arms disarms the system Command Start 8 default Close 8 14 Reset You can delete all registered information including passwords in order to return the original status before living factory Command 0000 VI How to use controllers 1 The remote cont
9. or Optional sensors detectors are packed separately It includes remote controllers wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster according your specific needs Typical house configuration m 4 External Sirens o Remote control Garage Doorfwingdow jj f r 4 f f WUZ 3 tf Smoke 2 i PIR Movement Detectors Detector Explanation of alarm systems 1 Working elements An alarm system contains two parts a main panel and some sensors When sensors detect unwonted situation they will send signal to main panel When main panel receives the signal it will activate siren to make 110dB sound to inform people around and dial out preset phone numbers for help 2 Function of each sensors detectors and main panel Sensors detectors include Door window contacts sensor PIR Sensor detectors and smoke gas detectors remote controls 1 Window door sensors are used to induct the close and open of doors or windows If a door is opened it will send signal to main panel 2 PIR Sensors detect the motioning object with infrared activities 3 Smoke gas detectors detect smoke or gas leak When detecting smoke or gas it will send signal to main panel 4 Main panel like a brain of the alarm system It will activate siren to make 110dB sound to attract attention from people pass by and auto dial preset phone numbers to call police and o
10. roller has four buttons Out Arm button set alarm works when no one is at home all the detectors will be in working status the light on panel will slowly flash green Home Arm button set alarm works when there is someone at home detectors which inside of the house in inner defense zone will not work only the detectors outside of the house in outside defense zone will work for the people inside can move conveniently but others who break in from outside will trigger the alarm Disarm button set main panel disarm all the detectors are disarmed the light on panel will keep in still green Alarm button set emergency alarm the light on panel will flash red the system will make alarm and the unit will send the SMS and dial out phone numbers 2 The process of receiving an alarm What should do when I receiving the phone call from the main panel When detecting something unwonted the detectors will activate the siren and dial out alarm phone numbers and the status LED will be on User can answer the phone and do it according the following steps Press to start the function of listen in for 30 seconds you will hear what is happening around the main panel Press to confirm that you have already received the signal of alarm and stop alarm If you do not input the main panel will continue to dial out all alarm phone numbers circularly 3 Remote control by phone You can call the host phone number to control th
11. t Zone It will activate siren and dial out users phone numbers no matter it is arming or disarming when the detectors in this defense zone are triggered 5 for Inner Zone It will not activate siren and dial out users phone numbers in the status of Home Arm E g If you want the second defense zone to be inner zone You can input 0225 Reminder for application Usually we setup the door window sensors installed in windows veranda and doors as Immediate Zone The detectors in this area will activate alarm in any mode of arming If you setup wireless PIR detectors as the Inner Zone they will work in the mode of Out Arm but do not work in the mode of Home Arm You can setup the doors in the main gates as Delay Zone if you do not want to take remote control when going out In this case you can disarm the system within 30 seconds after opening the door but the main panel will not have enough time to activate siren and dial out alarm phone numbers 6 Start close reminder for defense zone If you start the reminder for defense zone it will beep beep beep for three times to remind users of arming Command Start Zone No 71 Close Zone No 70 7 Start close the function of anti interfere When starting the function of anti interfere in arming status it will activate siren to alarm not calling users if someone interferes the alarm system with same frequency Command Start 17 1 C
12. to offer help Play the recorded message through the telephone please press 6 on the main panel 2 How do I Register sensors or detectors with main panel First as we all know every detector has its unique ID It must be registered with the main panel so that it can be identified during working When it detects unwonted status it will send signal to main panel If it did not register with main panel the main panel would not identify it and could not receive the signal so the alarm will be failed Before registering please input 7 with a beep the arm status flashing it shows on the status of registering Now you can start to register sensors Please collect all detectors including door sensors PIR detectors and gas smoke detectors together with the main panel and make sure their battery inside and can work normally Switch on main panel power LED is on and trigger the sensors or detectors you are going to check in 3 How to trigger sensors or detectors When the main panel is powered start to register them For door sensors just remove the two parts of door sensor and remove back it will beep and the status LED flashes which shows successful And for PIR Sensors you can turn the switch to on and the system will beep which shows successful and then turn it to off to avoid wrong alarm For remote controllers you can press any key on its panel three keys on it and the system also beeps For gas and smoke detec
13. tors there is a black switch on the left side you can press it to register it with main panel For break sensor you can put it on a desk and then shake the desk it will send a signal to main panel The main panel will response with a beep sound which shows successful After finishing registering please enter to exist two beeps 4 How to delete all coded information if you want to recheck in Under the status of registering please input 7 It will sound beep beep two times all coded information has been deleted IV How Can I setup the Alarm Phone Numbers The phone Nos that will be dialed out when there is an alarm Command 31 the 1st User phone number 32 the 2nd User phone number 33 the 3rd User phone number 34 the 4th User phone number 35 the 5th User phone number 36 the 6th User phone number 38 the 1st phone number of monitoring center 39 the 2nd phone number of monitoring center Note Do not setup the last monitoring center numbers if you do not have monitoring center You can enter a blank order if you want to delete a Alarm Phone Number Fox example You want delete the 4 Alarm Phone Number only input 34 Input password origin 1234 Alarm Phone No Settings 31 the 1st User phone number 32 the 2nd Use phone number 33 the 3rd User phone number 34 the 4th User phone number 35 the 5th Use phone number 36 the 6th User phone number Operation sketch
14. wners 5 Siren To make 110 dB sounds 3 We sell at a standard package Customers can add more sensors detectors if needed 4 Wireless sensors do not need wire to communicate with main panel They use wireless communication so wireless _sensors detectors have to be registered with main panel before working so that main panel can identify them when they send signal to main panel Technical Parameters Main panel Operating voltage DC 9V Back up battery inside Static current lt 50mA Operating Frequency 315MHZ or 433 HZ Wireless receiving distance 100m 250m Anti interfere ability 1 V m 20 1000Mhz Outer Alarm Siren Volume 110 db Working Condition Temperature 10 C 40 C Humidity lt 90 Capacity for Wireless Device 99 pcs Wireless Gap Detector Power Supply DC12V inner 12V battery Static Current lt 20 uA Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Interval Distance 15 mm Working Condition Temperature 10 C 40 C Humidity lt 90 Wireless P IR Detector Power Supply DC9V inner 9V battery Static Current lt 100 uA Transmission Current lt 20mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 Remote Contro
Download Pdf Manuals
Related Search
Related Contents
Melange - Melange Pro Anleitung Visualizza - Service, Support GLC2400 Series User Manual SERIES 5200 PISTON HAND PUMP - Fill-Rite Massive Suspension light 40392/29/10 Copyright © All rights reserved.
Failed to retrieve file