Home

Stagehand FX Manual 1.0

image

Contents

1. turning the knob move the cursor over the segment you wish to change In this example move the cursor until it is flashing over the number 32 Press the knob to edit the number 32 Turn the knob to dial in a new number for example rotate clockwise until you reach the number 36 Press the knob to stop editing the number Rotate the knob until the cursor is flashing on ORK Press the knob to accept the changes To discard a changed IP address you can click on Cancel in step 7 2 Using a Stagehand The real benefit of Stagehand is achieved when using it in conjunction with a PC running SpikeMark software SpikeMark allows you to program multiple motors to move at specified speeds to exact locations on stage These moves are written as cues and can be edited and run in a similar fashion to a lighting console 2 2 Manually testing a switched effect Before writing any cues confirm that your effect is properly connected to the Stagehand FX by testing these conditions 1 E Stop Release the E Stop button on Showstopper The LCD display should show that the E Stop is released by switching the status display to Figure 2 1 OT CONNECTED 92 168 10 32 Not Connected indicates that the Stagehand FX is not communicating with a computer running SpikeMark 2 Connection Establish a network connection to the Stagehand FX using the SpikeMark software Page 8 Stagehand FX Manual 3 Output In SpikeM
2. Stagehand FX Manual creative conners inc Stagehand FX Reference Manual Version 1 0 Copyright 2008 Creative Conners Inc All rights reserved Page 1 Table of Contents Stagehand FX Reference Manual 1 Getting Started Wed Whats Inthe DOK lionra added tina brat ee aiheaees 1 2 Stagehand FX OvervieW sinite LS lastalm Stash dune E oeiek 1 3 1 Mounting Stagehand cc csesssesssseeeeeeeeeeeeeeees 13 2 TOO KING UP DOW CF e a sete sca EATE 1 3 3 Hooking up a switched effect ccccccceeeceeceeeeeees 1 3 3 Hooking up an input SWitch cccececceeeeeeeeeeeeeees 1 4 Configuring a Stagehand Network 2 Using a Stagehand 2 2 Manually testing a switched effect eens 2 2 Cue Control with spike MarkG esitec ou ourcecdedekosr euteatedenk 3 Troubleshooting Technical SUPP Ol arsine AAA Phone SUP POM ennenen se Gicteas eed ita 4 Specifications A UPRYSIC Al Speci caon S ressora n ON 4 2 Electrical Specificati Nns asns nN T 3 Stagehand FX Manual Page 2 Stagehand FX Manual Stagehand FX Reference Manual 1 Getting Started Congratulations on your purchase of the Stagehand FX scenic input output controller from Creative Conners Inc Stagehand FX brings the excitement of automation to theatres of all sizes Stagehand FX is made to integrate simple switch devices into shows that are using Stagehand motor controllers with our SpikeMark software This manual w
3. ark using the on screen manual controls to close the output on the Stagehand FX The output light on the Stagehand FX should illuminate For more details see the SpikeMark user manual Figure 2 2 Output 1 Output Z Ou tout 3 Output 4 2 2 Cue Control with SpikeMark Stagehand FX receives cue information from SpikeMark over standard network cables and hubs SpikeMark will inform Stagehand FX which output switches to open or close When SpikeMark sends a GO command Stagehand will open or close the selected outputs thereby activating or deactivating your switched effects If an Emergency Stop signal is detected from the Showstopper the Stagehand FX will immediately disable all of its output switches Keep this in mind when designing your effects because it means that your effect should be in a safe state if power is removed from the activation circuit For more details on writing cues in SpikeMark consult the SpikeMark user manual 3 Troubleshooting Technical Support Though we try our best to produce reliable software and clear instructions there may come a time when you need personal support Phone Support You can call our technical support at 401 862 2980 Monday Saturday from 8am 6pm EST Phone support is free for 90 days after that a rate of 30 hr applies to support calls Web Support There is an active user support forum on our website http www creativeconners com phpBB2 index php Page 9 S
4. e network connection between the Stagehand and a PC running SpikeMark If an E Stop has been activated the condition will be displayed In address mode it will let you alter the current IP address 3 Ethernet The Ethernet receptacle accepts a standard RJ45 network cable Stagehand FX uses Ethernet as the control protocol to communicate with a PC running SpikeMark software 4 Output Indicators When the Stagehand FX closes an output switch the corresponding indicator light will illuminate 5 Output Connector The pluggable terminal block provides screw terminals to make connections to the four 4 relay outputs The relay outputs are dry contact closures allowing you to switch an power source you need The contacts are rated for 3A 120VAC maximum 6 Input Connector The pluggable terminal block provides screw terminals to make connections to the four 4 inputs The Stagehand FX will supply 12V on one terminal of each input and sense the presence of that voltage on the other terminal of the input You can wire any normally open N O switch rated for at least 12VDC to the inputs 7 E Stop The E Stop a k a emergency stop receptacle is a 5 pin XLR connector This receptacle receives a dedicated emergency signal 24VDC from a Showstopper base station If this signal is present the Stagehand FX is free to close any output when the signal is interrupted it will immediately open all relay outputs Page 4 Stagehand FX Ma
5. ill direct you through 1 Unpacking 2 Installing amp testing 3 Operation procedures If you need help along the way contact us either on our website www creativeconners com via email support creativeconners com or by phone 401 862 2980 1 1 What s in the box Inside the box you should find 1 Reference manual this document 2 Stagehand FX 3 Power cord If you purchased any Stagehand motor controllers power cables encoders limit switches or other accessories those items are packaged separately 1 2 Stagehand FX Overview The Stagehand FX performs two functions switching relay outputs amp sensing switch closure inputs This means that Stagehand FX can 1 Turn on amp off a power source to a simple effect like a solenoid valve lights or small motors 2 Detect when a switch has been closed eg a limit switch or pushbutton After unpacking your Stagehand FX take a moment to familiarize yourself with its various connections and features Page 3 Stagehand FX Manual Figure 1 1 shows the connections and controls located on the front of the Stagehand FX From left to right these connections are Figure 1 1 Stagehand FX 1 Knob The knob is used to set the IP address Press the knob it s also a button and then turn the knob to adjust the address 2 LCD Display The display shows information about the Stagehand s status When idle it shows the current IP address and the status of th
6. lve external power supply 1 3 3 Hooking up an input switch The Stagehand FX has four 4 inputs that can be used to detect a switch closure By using normally open switch connected to a Stagehand FX input you can trigger cue links in the SpikeMark software when the switch is closed Figure 1 11 shows a typical input connection Figure 1 11 Page 6 Stagehand FX Manual Stagehand FX Inputs Internal Control 1 2 3 4 opto isolator opto isolator opto isolator opto isolator 12VDC 12VDC 12VDC 12VDC 1 4 Configuring a Stagehand Network Many Stagehands can be controlled by a single PC running SpikeMark software The SpikeMark controls Stagehands through standard network cables and hubs The following diagram shows a typical network of Stagehands Figure 1 13 ethernet Windows PC Showstopper running 3 SpikeMark Network Hub Stagehand Effects Every component on the network must have a unique IP address Though you can alter any of the four segments of the Stagehand s IP address it is often easiest to alter the last number valid ranges for each segment are 0 to 255 To change the address of a Stagehand follow these steps 1 Ifthe E Stop is engaged release the E Stop on Showstopper Page 7 7 8 Note Stagehand FX Manual Push the knob on the front panel of the Stagehand The LCD display will change to show that you can edit the IP address Figure 1 14 UK CANCEL 92 168 10 32 By
7. nual Figure 1 2 Figure 1 2 shows the power connection located on the back of the Stagehand FX The input power connector is fused with a 5mm x 20mm glass fuse rated for 1 25A 1 3 Installing Stagehand 1 3 1 Mounting Stagehand The Stagehand FX is packaged in a standard 2U 19 rackmount case You can mount in a 19 rack or simply set it on any flat surface Take care not to block the ventilation slots on the sides of the case 1 3 2 Hooking up power Once you have plugged in the Stagehand FX power cord the LCD display should light up and display the following note IP address may be different Figure 1 9 E Si UP 92 168 10 32 The E Stop message is displayed because you have not yet hooked up the Stagehand with Showstopper If the Stagehand does not detect a signal from Showstopper it will assume and Emergency Stop condition The number on the bottom line of the display is the Stagehand s IP address We ll look at changing the IP address in section 1 4 1 3 3 Hooking up a switched effect Page 5 Stagehand FX Manual The Stagehand FX has four 4 switched outputs that can be used to control any simple on off device The switched outputs located on the front panel are dry contact closures in other words the Stagehand FX doesn t provide any power from those outputs just a switch closure Figure 1 10 shows a typical output connection Figure 1 10 Stagehand FX Outputs Internal Control solenoid va
8. tagehand FX Manual Email If you have a technical question you can email technical support support creativeconners com 4 Specifications 4 1 Physical Specifications The Stagehand FX is packaged in a standard 19 x 2U rackmount case The overall dimensions are 17 W x 8 D x 3 7 167H 4 2 Electrical Specifications Power supply voltage 120V 60Hz Max power supply current 1 25 amps Switched output contact rating 3A 125VAC Control input rating dry contact closure Page 10

Download Pdf Manuals

image

Related Search

Related Contents

Transcend 2048MB DDR2 667MHz FB-DIMM dual rank  Instruc 118417-037-608038a.qxd  Apotop DW17  TP-Link TL-WN721N Declaration of Conformity  簡易型電文設定器に関するご質問の回答  Samsung ACM-F100 User Manual  消火器の安全に関する表示を充実  Saphir vario  IMPRESSION 3D  H.264 NETWORK Embedded DVR  

Copyright © All rights reserved.
Failed to retrieve file