Home

MONITECH-QT_user_manual-2-22-08-Eng

image

Contents

1. appointment card Please be sure to call this number if you ever need to reschedule your monitoring appointment Remember that all monitoring checks are performed by appointment and in the order they re scheduled While we will do everything possible to make your visit go as smoothly as possible previously scheduled appointments will often prevent us from being able to service your Interlock at a time other than your scheduled appointment For that reason it is not recommended that you arrive too early Of course when possible we will be glad to service your vehicle early and get you on your way Anytime you wish to come for an appointment other than the scheduled time BE SURE to call the Customer Service Center Because of the number of Service Centers it is not always safe to assume that there will be a Service Technician available if you just show up When it is time to have your Interlock serviced the QuicTest unit will notify you each time it wakes up beginning seven days from your scheduled appointment This signifies that you have seven days to return to a Service Center for a monitoring check Please note that failure to report for your Monitor Appointment may cause the vehicle to go onto Permanent Lockout Assuming that no problems are encountered a monitoring check will generally last 15 to 20 minutes During this time the Interlock is tested and calibrated the internal clock is reset to allow another two months driving
2. driver s ability to safely operate a motor vehicle Under no circumstances should you attempt to drive if you have been consuming alcohol This not only puts you and other driver s at risk but may violate the terms of your Interlock Program subjecting you to additional fines and or the loss of your license There are no user serviceable parts in your Interlock unit DO NOT ATTEMPT TO OPEN OR TAMPER with any part of the device Doing so WILL disable your vehicle and be a violation of your program resulting in additional fees and or the loss of your license Do not attempt to introduce anything other than clean human breath into the device Introduction of any other sample will result in an Invalid Sample and abort the test and prevent your vehicle from starting Test criteria requires a clean mouth cavity no eating drinking etc for five minutes prior to blowing a sample Remember to remove gum candy smokeless tobacco and foodstuffs etc from your mouth and to clear your lungs mouth of any cigarette smoke or other fumes before taking the test The QuicTest Interlock will not fail you for substances other than alcohol but other substances especially cigarette smoke can damage the Interlock BE CAREFUL YOU WILL BE CHARGED FOR ANY DAMAGE TO THE INTERLOCK CAUSED BY CIGARETTE SMOKE OR OTHER FOREIGN SUBSTANCES BLOWN SPRAYED POURED OR SPILLED INTO THE UNIT Do not attempt to abuse or mistreat the device in any way Such acti
3. requested and take a Breath Test as instructed by the unit and described in Section 5 Page 12 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 If you do not take an Engine Off Test in the 10 minutes provided the ALARM MODE will be activated your siren will sound and your hazard lights will flash You MUST pull off the road in a safe place and turn off the vehicle at this time The only way to silence the alarm is to turn off the vehicle When you turn off your vehicle it is normal for the alarm to continue for a few seconds before shutting off The activation of Alarm Mode will also generate a 3 day Service Recall If you can not find a safe place to stop for an Engine Off Test within the allotted 10 minutes continue driving until a safe location is found Under normal driving circumstances it is rare that a safe location can not be found if the participant begins looking as soon as the alert is sounded You may ignore an Engine Off Test request if you are about to turn the vehicle off however you may be asked to take a test when you arrive at your destination see Arrival Test below c HOURLY ENGINE OFF TEST Some State Agencies such as North Carolina require an Engine Off Test to be taken after every 60 minutes of continuous driving If you have been driving for a full hour the unit will announce An Engine Off Test is required You have 10 minutes to pull off the road in a safe location turn off the ve
4. Breath Test required at random time intervals while the vehicle is being driven This can be taken as you drive or you may pull off the road in a safe place and take it while the engine is running Service Mode This allows your vehicle to be serviced by a certified mechanic when your vehicle requires automotive not Interlock service It provides the mechanic with a means to diagnose and operate the vehicle for a very limited amount of time without having to un install the device or take a Breath Test It requires a phone call from the mechanic to your Service Provider Siren This is the Alarm Siren that was included in your Interlock System installation Stall Protection A 2 minute period of time after the engine is turned off for any reason including engine stall It allows an immediate restart without the need to take a Start Test to ensure the driver is able to quickly move from an unsafe location i e railroad tracks a busy intersection etc in the event of an engine stall Start Test The Breath Test taken to allow you to start your vehicle Temporary Lockout A short period of time typically 5 or 30 minutes when vehicle Start is not permitted This occurs after a failed Start Test The first failure will normally result in a 5 minute lockout If the next test is also a failure the next lockout and any following will be for 30 minutes Visual Alert Device VAD This is a small flashing light that can be insta
5. EST The first of these is the Random Running Test If required by your program you will be asked to take a RUNNING TEST at random time intervals When this occurs the unit will alert you with 2 beeps and say A Running Test is required You have 3 minutes Take Running Test as soon as you can safely do so off the road or while the vehicle is underway At this point the unit will display HOLD TRIGGER AND BLOW as it waits for you to take a Breath Test It will repeat this request at 2 minutes and again at 1 minute You have the option of taking this test while you are driving or pulling off the road ina safe place and taking the test with the engine still running This Test is designed to be simple enough to take while the vehicle is in motion There is no need to actually look at the QuicTest Sample Head Simply pick it up Your fingers will fall in place around the handle and your index finger will be on the TRIGGER Press the TRIGGER and raise the device to your mouth and blow a breath sample as described in detail in Section 5 If the result of your RUNNING TEST is PASS the unit will return to RUNNING MODE If the result of your RUNNING TEST is WARN the unit will announce Warning a low level of alcohol has been detected If further tests show higher levels you may be required to stop the vehicle before reaching your destination The unit will then return to RUNNING MODE If the result of your RUNNING TEST is FAIL the un
6. Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 monitech y interlock systems gt QuicTest QT 1 Operators Manual Monitech Interlock Systems 215 Southport Drive Suite 400 Morrisville NC 27560 919 459 1700 local 800 521 4246 toll free Page 1 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Table of Contents 1 Important lINFORIMAUON Gs sssaaa ai aai EERE 3 2 QuicTest OvervieW ssessesssssrsrrsrrerrerrrrrrrrrrrrrrrerrsrrsrrsrtn 4 3 QuicTest Menu Functions NN ROU irri OG ar eee A ie canted E a ui aided Sa 4 Men MOOG mrana a E E pO EEE EE 4 e Redundant buttonS sssssssssesrerrerrerrrrrrrrrerrerrerrerrn 5 e Personal Identification Number PIN eeeeeeeeee eres 5 e 2 aE E eee aie eee a Ree cP ee Poe Reena eee eee ee ee 5 Bs BAG CMCC asneira nen anar one a EEA eran surads EEEE deta 5 Volume AGUS s ena denser a EEEE EEEE 5 e Language SelectlOn asc cc ieee lee atelier ee ea 5 e Sample Head Hemoval ic vs cissa2eissseepiiates es tapeseieecaxeeeeed 5 e Service MIOGG ers cise saadceies eat ca cennacabins Saveunseatieaeagdonacetea Gana 6 e Override NOU ac ctentan weer ruccdeesap seni vate crceuseete ecceea eae 6 e Appointment CNOCK a ccscs gelesen aii tadshe dee Satewsiesaien aieandueelated es 6 OVSE mM IMO ei eee ee hee ie entre 6 4 Glossary of TOI Ss seee acts chee halois ced skin as cae elozano i ee 6 5 Taking a Breath Test rrepe
7. This will allow you to get the vehicle to a Service Center for servicing If this has occurred call your Service Provider and request QuicTest Support If at all possible call with a cell phone so you can be with the unit in your vehicle Unless warranted this service may require additional charges Section 11 Care of Your Interlock Unit e Your QuicTest Ignition Interlock is a complex instrument With proper use and handling it will help you comply with your Interlock Program requirements in a simple easy to use manner with minimal inconvenience however improper or rough handling or attempts to tamper with or circumvent the unit may result in vehicle lockout alarm activation service fees or loss of license e Always keep the Sample Head clean dust free and dry at all times While the Sample Head is water resistant it is NOT water proof Service calls resulting in exposure to water or other liquids may be charged to the customer e Do not leave the unit in Direct Sunlight i e on the dashboard on a hot day e Do not pull excessively on the coil cord that is connected under the dashboard e There are no user serviceable parts in your Interlock unit DO NOT ATTEMPT TO OPEN OR TAMPER with any part of the device Doing so WILL disable your vehicle and be a violation of your program resulting in additional fees and or the loss of your license e Always use a clean QuicTest Disposable mouthpiece when taking a Breath Test As lon
8. alid Sample Mouth Contamination Any alcohol that may be present in the mouth only due to very recent use of mouthwash cough medicine or a sip of an alcoholic beverage This is normally gone within 5 minutes of use Override Code This is a single use code that your Service Provider may use to allow you to operate your vehicle for a limited time in the event that your unit has gone into Permanent Lockout due to a missed appointment caused by extreme circumstance This may be used for situations such as natural disasters severe weather serious illness hospitalization etc Anytime your unit is in Permanent Lockout call your Service Provider Pass A Breath Test result lower than the Warn level set by your State Agency Pending Service Date Notification As the Scheduled Service Appointment approaches the unit will notify the user each time the unit wakes up Also if the unit is in recall the unit will notify the user that service is required in the next X days before lockout occurs so that an urgent Service Appointment can be made Permanent Lockout A condition that does not allow vehicle Start at any time for any reason This could be the result of a missed Service Appointment tampering with the unit or unit malfunction If the unit is in Permanent Lockout you must call your Service Provider PIN A Personal Identification Number that must be entered to operate the unit Program Violation Any event th
9. at is a violation of your Interlock Agreement This may include Breath Test failures if applicable excessively high failures tampering with the unit attempting to alter or circumvent the installation of the unit driving during restricted drive times if applicable ignoring required tests such as an Engine Off Test or other actions specific to your agreement with the State Agency and Service Provider you are working with Page 7 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Recall A requirement to bring your vehicle back to your Interlock Providers Service Center within a limited number of days for servicing of the unit This is generated by a pending Monitor Appointment a program violation unit malfunction or suspected tampering or abuse of the unit Redundant Alcohol Sensor In the event that the Primary Alcohol Sensor in the unit malfunctions a Secondary Alcohol Sensor may be used depending on the requirements of your State Agency This will allow vehicle operation for a limited number of days until you can reach your Service Provider s Service Center for repair This sensor may be sensitive to substances other than Alcohol so it is very important that you ensure that you have not been eating smoking or drinking ANYTHING other than water for at least 5 minutes prior to any Breath Test Failure to do so may result in Temporary Lockout until your mouth is clear of all residues Running Test A
10. ber that will override the lockout and allow you to drive for a limited time until you can get to a Service Center To use this option call your Interlock Service Provider and ask the operator for QuicTest Support Unless warranted this service may require additional charges Appointment Check This allows the user to check the date of the next scheduled Monitor Appointment To check your appointment date press the TRIGGER from this option Your next appointment date will be displayed for a few seconds and then return to the Menu Mode This is the appointment made at_the last Service Center visit Changes to your appointment made over the phone or appointments required due to a recall are NOT visible when using this feature System Info This function will display the Serial Number and Firmware level of your QuicTest Sample Head and Control Module Section 4 QuicTest Glossary of Terms Alarm or Alarm Mode This occurs when you have violated a critical requirement that you were instructed to follow If the unit enters Alarm Mode the unit will instruct you to safely pull over and turn off your vehicle During this time the Interlock System siren will sound the vehicle hazard lights will flash and your horn may sound The only way to stop this is to turn off your vehicle Alarm Mode occurs due to the failure to take an Engine Off Test when required an unauthorized vehicle start or the disconnection of the Sample Head while the v
11. e in your hand for a moment or blow through it without it being inserted into the unit to warm it up It is possible for a very cold mouthpiece to cause an Invalid Sample 3 If you have successfully completed the blow the unit will display ANALYZING and then will indicate the results of the test in terms of a PASS WARN or FAIL with further instructions depending on the specific test you are taking Section6 Starting Your Vehicle with QuicTest This section describes how to start your vehicle Please refer to Section 5 for instructions on how to take a BREATH TEST before reading this section WARNING You can be arrested and convicted of DWI even though you might pass the Ignition Interlock test with a level of alcohol in your body that is normally not prohibitive This is especially true if you are involved in a traffic accident or stopped for driving or other vehicular violations Even a small amount of alcohol causes impairment in decision making and coordination activities especially driving Ultimately it is your choice whether to drive after drinking alcohol The Ignition Interlock does not relieve you of the legal responsibilities related to driving after drinking any amount of alcohol and can not be used as a legal defense in a court of law 1 To START your vehicle select START TEST from the menu mode Enter your PIN if requested Page 9 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 2 Follo
12. ehicle is in operation Appointment Check This feature allows the user to check the date of their next regularly scheduled Monitor Appointment This is the appointment made at the last Service Center visit Changes to your appointment made over the phone or appointments required due to a recall are NOT visible when using this feature Arrival Destination Test A Breath Test that may be required when you turn your vehicle off Aggressive Mode If your Breath Tests Start or Running result in alcohol levels in the Warn or Fail range the frequency of Running Tests you will be required to take will increase for a period of time BAC Test A Breath Test that can be taken without the vehicle in operation and not part of the vehicle start sequence to determine your Breath Alcohol Content in terms of Pass Warn or Fail This option may not be available in all states Blow Tone An audible tone generated by the unit as you take a Breath Test to indicate that you are blowing at an acceptable pressure Page 6 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Breath Alcohol Ignition Interlock Device BAIID A device that prevents a vehicle from starting based on a Breath Alcohol Sample Breath Alcohol BrAC The level of alcohol present in a deep lung alveolar breath sample Data Logging The recording of all unit user and vehicle events into the unit memory Diminished Lung Capacity Some Int
13. emove the mouthpiece and warm it up by holding in your hand or blowing into it before inserting it back in the QuicTest and taking a Start Test Failure to do this may result in an INVALID SAMPLE If the vehicle IS NOT RUNNING and the QuicTest unit does not wakeup or seems to have Locked up without going to menu mode disconnect the coil cord from the Sample Head wait a few seconds and reconnect If this does not correct the problem call the Monitech Customer Service Center If the unit states that it is in Permanent Lockout or displays UNABLE TO TAKE TEST call the Monitech Customer Service Center There may be a 4 digit number on the display after the Permanent Lockout message if so write it down and tell that number to the Customer Service Representative you speak with Section 13 Potential problems with the vehicle If the Ignition Interlock will not wakeup or the display indicates LOW VEHICLE BATTERY it means the Interlock is not getting enough voltage to allow a test Check your battery terminals and charging system If you pass the Interlock test but your vehicle will not start there is a high probability of a fault in your starting system although sometimes a low battery voltage can be the problem This difficulty is often in the starter starter solenoid the ignition switch or the connections in between Such problems should be addressed by a qualified automotive mechanic Page 15 of 17 Monitec
14. erlock users may have difficulty blowing into the Interlock due to a legitimate medical condition such as asthma or emphysema If this condition applies to you and your State Agency allows this feature your Service Provider can adjust the Interlock to meet your specific diminished lung capacity See your state Department of Motor Vehicles or your Service Provider for more information Diminished Running Retest The requirement for you to take Running Tests as you operate the vehicle may decrease as a reward for program compliance This is based on the number of alcohol free starts you have over a long period of time This is also dependant of the requirements and limitations of the State Agency you are working with Engine Off Standing Test A Breath Test that must be taken with the car stopped in a safe place and the engine turned OFF Fail A Breath Test result that is equal to or greater than the Fail Level set by your State Agency Flashers The hazard flashers and or turn signals of your vehicle High Fail A Breath Test result that meets or exceeds the definition of a High Fail as set by your State Agency Hum Tone Some State Agencies require the user to hum while they blow into the device for a Start Test If your agency requires this you will be trained on how to do this when your Interlock is installed Invalid Sample Any sample that is blown into the unit that is not direct unaltered human breath is an Inv
15. g as the mouthpiece remains clean it is not necessary to use a new mouthpiece every time Page 14 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Do not attempt to introduce anything other than clean human breath into the device Introduction of any other sample will result in an INVALID SAMPLE and abort the test and prevent your vehicle from starting Remember to remove gum candy smokeless tobacco and foodstuffs etc from your mouth and to clear your lungs mouth of any cigarette smoke or other fumes before taking the test The QuicTest Interlock will not fail you for substances other than alcohol but other substances especially cigarette smoke can damage the Interlock BE CAREFUL YOU WILL BE CHARGED FOR ANY DAMAGE TO THE INTERLOCK CAUSED BY CIGARETTE SMOKE OR OTHER FOREIGN SUBSTANCES BLOWN SPRAYED POURED OR SPILLED INTO THE UNIT If it will be extremely cold outside or your vehicle will be without power or you know your battery is low go to REMOVE UNIT in the Menu Mode Press the trigger and disconnect the coil cord from the Sample Head when instructed to do so Take the unit in the house and reconnect it again before you drive Do not attempt to abuse or mistreat the device in any way Such activity may be detected and recorded and may result in service charges fines or loss of license Section 12 Potential problems with the QuicTest If the outside temperature is very cold remember to r
16. h Interlock Systems QuicTest User Manual Rev A 2 16 08 If the Interlock does not power up your battery may be completely discharged Have your automotive repair center ie service mechanic auto parts store etc check your battery They can advise you as to whether your battery may need to be charged or replaced If your Interlock does not power up after this or any other repair work has taken place on the vehicle call Monitech immediately Did the problem appear after other work took place on the vehicle Check the fuses Have you installed a stereo telephone or any other item that could have caused other wires to come loose or a fuse to blow Remember that the Ignition Interlock can only prevent your car from starting Once your vehicle is running the Ignition Interlock can not make your vehicle shut off If your vehicle is running rough stalling out while underway or won t start even though the starter is clicking or turning over the difficulty can not be the Ignition Interlock Such problems should be addressed by a qualified automotive mechanic Section 14 Monitoring Appointments Before you leave the Service Center please be sure to schedule your first monitor check appointment at the Monitech Service Center of your choice Although we do have Service Centers throughout the state all appointments are scheduled through our Customer Service Center which you can contact during regular business hours The number appears on your
17. hicle and take an Engine Off Test Failure to perform this within 10 minutes will activate alarm Please follow the instructions in Section 7 3 6 above It is recommended you plan for Hourly Engine Off Tests especially on long trips by taking advantage of rest areas fuel stops and to use the rest room etc rather than waiting until the last minute when an appropriate stopping place is much more difficult to find d ARRIVAL DESTINATION TEST If you reach your destination during a RUNNING TEST request or an ENGINE OFF TEST request and have not yet taken the Test prior to turning off the vehicle you will be asked to take an Arrival Test before leaving the vehicle Failure to take an Arrival Test will not activate alarm but may be a Program Violation depending on your State Agency s Interlock Program Requirements and will be recorded in the unit s event log To take the Arrival Test when instructed by the unit follow the steps for taking a Breath Test in Section 5 3 Stall Protection If your vehicle stalls at any time you may re start it without being required to take a BREATH TEST for up to 2 minutes after the engine has stalled Turn the ignition switch off and then start the car as you normally would Even if you stalled during a Test Request and the unit is asking for an Arrival Test you may restart the vehicle in this manner after a stall 4 Restricted Drive Times If your Interlock Program has restricted your dri
18. isplayed press the TRIGGER to set the language Remove Unit NOTE AS AN ANTI THEFT MEASURE IF THE SAMPLE HEAD IS REMOVED WITHOUT SELECTING THIS OPTION THE VEHICLE SIREN WILL SOUND This option allows the user to remove the Sample Head from the vehicle if desired This may be done for the following reasons e To prevent theft e To protect your vehicle battery during long periods of inactivity beyond 5 days such as vacation for several weeks e To protect the device from extreme cold temperatures To remove the Sample Head press the TRIGGER from this option and then remove the unit when instructed to Do this by grasping the knurled part of the connector barrel only and pull it straight back until the connector releases Page 5 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 When you reconnect the unit it may require a short amount of time to re establish communication do a system check and warm up When you see the asterisk scroll across the bottom of the screen you may wake the unit up and proceed Service Mode This option is used if the vehicle requires automotive non Interlock service by a mechanic To use this function instruct the mechanic to call Monitech and to ask the operator for QuicTest Support Override Mode In the event that your unit is in PERMANENT LOCKOUT due to a malfunction or missed Monitor Appointment it may be possible to have the Service Provider Office issue a num
19. it will announce An Engine Off Test is required You have 10 minutes to pull off the road in a safe location turn off the vehicle and take an Engine Off Test Failure to perform this within 10 minutes will activate alarm If the result of your RUNNING TEST is H FAIL you will have only 3 minutes to take an Engine Off Test If you choose to ignore the request for a RUNNING TEST or you do not feel you can safely perform it with the vehicle underway and there is no safe place to get off the road you can allow the 3 minute RUNNING TEST window to expire If you do this the unit will then announce An Engine Off Test is required You have 10 minutes to pull off the road in a safe location turn off the vehicle and take an Engine Off Test Failure to perform this within 10 minutes will activate alarm There is no penalty for choosing to stop for a standing retest rather than attempting an unsafe Running Test Ultimately it is your choice of whether to attempt a rolling retest or to find a safe location in which to stop and perform the Test b ENGINE OFF TEST Messages requesting the Engine Off Test will continue at 5 3 2 and 1 minutes until the time for you to test has expired Find a safe place to pull off the road Never pull off on the shoulder or into the emergency lane or the median of a highway get completely off the highway on a side street parking lot turn around etc Turn the vehicle completely off enter your PIN if
20. ll go to sleep within 3 to 6 minutes sometimes longer This is indicated by an asterisk that slowly moves across the bottom of the display To wake the unit up you may either pick it up and move it or press any button The unit will wakeup and say QuicTest by Monitech A brief stand by period countdown may begin depending on how long the unit has been asleep and the outside temperature During this time the unit is verifying that it is functioning properly and warming up At the end of the standby period the LCD will display START TEST unless there are lockouts recalls or other service needs These will be addressed in a later section Menu Mode After the unit has woke up and played any recall messages or other notifications the display will read START TEST At this point the unit is in MENU MODE and any of the following functions described below are available by using the BACK NEXT and TRIGGER buttons Page 4 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Redundant Buttons In the event that any of the 3 buttons used to operate the unit becomes inoperable the remaining buttons will assume that function as follows e Ifthe LEFT button is not working use the RIGHT button to scroll all the way around e lf the RIGHT button is not working use the LEFT button to scroll all the way around e If the TRIGGER is not working at any time press BOTH the LEFT AND RIGHT buttons at the same
21. lled as an option on the vehicle dashboard for hearing impaired users This will alert the user who may not hear the audible prompts and messages that new information text is being displayed on the unit s LCD that requires their attention when they can safely do so Warn A Breath Test result equal to or greater than the Warn Level set by your State Agency but below the Fail Level Warning Any caution message the device issues due to a user error or upcoming violation These include the detection of a level of Breath Alcohol below your set Fail Level accidentally trying to start your vehicle before taking a test driving your vehicle close to a restricted drive time if applicable and a variety of other events Section5 Taking a Breath Test with QuicTest The following instructions apply for any of the required tests START RUNNING ENGINE OFF ARRIVAL or BAC 1 Before taking a Breath Test make sure that your mouth is completely empty and has had nothing other than water in it for at least the last 5 minutes If needed rinse your mouth with water to remove any other substances Taking a Breath Test with food beverage or smoke residue may impact the results or damage the unit and possibly delay starting your vehicle Page 8 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 or arriving at your destination Make sure that you have a Monitech Disposable Mouthpiece inserted into the Mouthpiece Port as show
22. more then an EARLY RECALL will be initiated You will have 3 days to bring the Interlock vehicle into one of the Monitech Service Centers to have the system downloaded A printout of the excessive alcohol level s will then be forwarded to the Division of Motor Vehicles or related jurisdiction for review and action Failure to bring the vehicle into a Monitech Service Center for EARLY RECALL will result in a permanent lockout and your vehicle s Ignition Interlock will require special service at your expense before allowing vehicle startup again If the unit indicates a FAIL or HI FAIL with POSSIBLE MOUTH CONTAMINATION You have blown a sample that contains more alcohol than the Fail or High Fail Level Page 10 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 established for your Interlock Program however it appears that it may be due to a high level of Mouth Contamination see Glossary of Terms not a true deep lung BrAC If it is Mouth Contamination it will decrease quickly The unit will offer you the option of holding the trigger button continuously for 3 minutes to allow a quicker retest opportunity and avoid Temporary Lockout If you choose to do so at the end of 3 minutes you may retest If you do not hold the trigger down for 3 minutes you will be in Temporary Lockout 5 or 30 minutes depending on if this was your first test of this start attempt or a subsequent one While the unit will never allow you
23. n in Figure 2 1 2 When instructed by the device press and hold the TRIGGER take a deep breath and blow into the mouthpiece You will hear a Blow Tone to indicate that you are blowing with the correct pressure Continue blowing until you hear a Pop and THANK YOU then immediately stop blowing and release the TRIGGER If you stop blowing before the Pop or take your finger off the TRIGGER before the Pop the test will abort and you will have to try again when instructed by the unit After the unit clears itself you will hear a pump run for a moment another test may be taken If you were blowing too hard or too soft follow the instructions given and try again when instructed by the device You may need to wait a moment or two for the unit to purge any partial breath samples and reset After the unit clears itself you will hear a pump run for a moment another test may be taken If the unit indicates INVALID SAMPLE the unit may have been exposed to something other than a human breath and has aborted the test After the unit clears itself you will hear a pump run for a moment another test may be taken Keep in mind that blowing anything other than clean human breath into the device will result in an Invalid Sample and abort the test preventing your vehicle from starting NOTE If you are blowing a sample on a day when the outside temperature is quite cold it is recommended that you hold the disposable mouthpiec
24. ng the ignition key or in very recent models pushing the ignition switch as you normally would As soon as your vehicle is started you may begin to drive The display on the unit may say OK TO START for an additional 2 minutes typically 30 seconds and then the unit will display RUNNING To learn more about unit operation and testing requirements as you continue to drive please see Section 7 0 If the unit indicates a FAIL only You have blown a sample that contains alcohol equal to or greater than the Fail Level established for your Interlock Program If this is the first sample you have blown for this start attempt the unit will go into a 5 minute TEMPORARY LOCKOUT If this is a second or more attempt after an initial Fail the unit will go into TEMPORARY LOCKOUT for 30 minutes You will be able to see how much time is remaining before the lockout expires on the display At the end of each Temporary Lockout period the unit will return to menu mode at the START TEST option At this time you will be able to take another Test Please remember that you should not have had any substance in your mouth other than water for the 5 minutes prior to the Test If the unit indicates a HI FAIL only This indicates that you have blown a sample that is equal to or greater than the High Fail limit set by your State Agency This may also cause the unit to initiate a 3 day Service Recall IMPORTANT If the Interlock detects a BAC level of 08 or
25. oval from the Interlock Program and revocation of your driving privilege Do not Test or attempt to drive if you have been drinking even small amounts of alcoholic beverage Excessive alcohol intake can require 12 to 24 hours before dissipation takes place Section8 QuicTest Operation While Driving Your Vehicle This section describes operation and interaction with QuicTest while you are driving your vehicle Please refer to Section 5 for instructions on how to take a Breath Test and Section 6 for instructions on how to start your vehicle before reading this section 1 Once your vehicle is started and you are driving the display will read RUNNING This is the normal mode of the unit when you are driving None of the Menu Mode options such as Adjust Volume Select Language APPOINTMENT CHECK etc are available while the vehicle is underway Also under no circumstance should you disconnect the Sample Head from the coil cord during vehicle operation Doing so will result in ALARM MODE Periodically the unit will make a buzzing sound for about 10 12 seconds This is normal unit operation and does not indicate a malfunction The unit contains a pump that periodically circulates fresh air through the unit Page 11 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 2 As you are driving there are timed events that you will be required to comply with as part of your State Agency Interlock Program a RANDOM RUNNING T
26. ri reena aea aE 8 6 Starting your vehicle with QuUICTESt cceceeeeeeeee eee eee eee ee enn 9 7 Information about Alcohol Failures c cceceeeeeeeeeeeeeeeeeeeeeees 11 8 QuicTest operation while driving your vehicle 6 e eeeeeeees 11 RUNAING Modia aa nares ica tren ila A a reeks 11 e Required Tests snnenenesresnerrerrsrrrrrerrerrrrerrerr rerne 11 e f your vehicle Stalls ic siete ce cece dawens ceciend ayeaavecetenersscueaeeshs 13 e Restricted Driving TimesS cceeeeeeee eee ceeeeeeeeeeeees 13 9 Service M da ihein aa a a A Aae Aa 13 10 Override Mode snessessessessessrssrsrrrrrrrrrrrerrrerrrnernernsrrerrerene 14 11 How to care for you Interlock Sample Head cceeeeeeeeeeeee 14 12 Potential Difficulties with QuicTest 0 cece cece eee eens ee ee ee ee ees 15 13 Potential Difficulties with your vehicle c cceeeeeeeeeeeeee teenies 15 1 MONITGF Appointments sc crak centivese enema lebets obser ide bi ialecledebbaness 16 15 Interlock Program Do s and Don ts 0cceceeeeee cece cess ee eeeeeaeaees 16 Page 2 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Section 1 IMPORTANT INFORMATION for the QuicTest BAIID The QuicTest Breath Alcohol Ignition Interlock Device offers state of the art alcohol measuring and driver interaction however the use of this device does not guarantee the
27. tacted within 20 minutes Do keep the Operator Manual next appointment date and emergency number in your vehicle at all times Don t disconnect any wiring that might be related and or connected to the Ignition Interlock in any way Call Monitech before disconnect if there is any doubt Don t allow anyone who might have alcohol content on their breath to attempt a test just for fun All alcohol readings are assumed to belong to the participant Don t allow anyone to drive the vehicle if you are not willing to accept responsibility for any alcohol readings that might result Do remember to plan ahead for Standing Retest stops Do look for safe lighted areas away from traffic flow when stopping for an Engine Off Test Don t leave the ignition switch ON without starting the vehicle Do review the Operators Manual periodically Page 17 of 17
28. time and a data logger report listing of the Interlock s memory is downloaded to determine if any violations and or alcohol failures have occurred in the past two months Page 16 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Section 15 Do s and Don t of your Interlock Program Do contact Monitech emergency service if the vehicle must be used by untrained persons in an emergency situation or if the emergency has caused you to be unable to successfully complete the test Don t attempt to hot wire cross ground or roll start your vehicle in an attempt to CIRCUMVENT the Ignition Interlock The Interlock will record such actions go into IMMEDIATE RECALL and the horn will blow The charging system of your vehicle may be damaged License revocation is probable Don t allow mechanical work that might require vehicle startup in your absence without providing the Monitech toll free number to the service technician Instruct all involved that Monitech must be contacted BEFORE any related wiring is detached and or a service CIRCUMVENTION is attempted Don t avoid a monitoring appointment because of financial difficulty Call the Monitech Office to make special payment arrangements Your appointments must be kept When contacting emergency service after hours make sure that you leave a phone number that you can be reached at in the next 20 minutes Call emergency service back if you are not con
29. time for TRIGGER functionality Personal Identification Number PIN When the unit was installed you were issued a 4 digit PIN The purpose of this number is to confirm timing and coordination and ensure only you or persons that you intend are able to operate the unit Before taking any Standing BAC Test Start Arrival or Engine Off you will be asked to enter your PIN Depending on how your unit is configured you may also be asked to enter your PIN when the unit wakes up To enter PIN use the BACK or NEXT buttons to scroll to the desired digit then press the TRIGGER to enter Repeat for each of the next 3 digits Start Test This menu option is used to take the test that allows you to start your vehicle To take this test press the TRIGGER See Section 6 for further instructions Adjust Volume This function allows the user to adjust the audio volume when the vehicle is NOT RUNNING To adjust the volume press the TRIGGER from this option and the use the LEFT DOWN and RIGHT UP buttons until the desired volume level is achieved and then press the TRIGGER to set the volume to that level Select Language This function allows the user to select the language that will be displayed in the text and played for the audio To select another language press the TRIGGER from this option and use the LEFT BACK and RIGHT NEXT buttons until the desired language is displayed This unit offers English and Spanish When the desired language is d
30. to start a vehicle with any FAIL result mouth contaminant or true BrAC if a breath sample is identified as having POSSIBLE MOUTH CONTAMINATION you are offered the opportunity of a quicker retest and the report that is submitted to your state agency will show that this result may have been mouth contamination Section 7 IMPORTANT INFORMATION ABOUT ALCOHOL FAILURES Every person s body metabolism is different and will even vary from day to day in the same person The only way to guarantee your ability to pass the Alcohol Test is to avoid alcohol intake for 24 hours prior to testing Since all alcohol failures will be recorded as part of your permanent record with Monitech and the agency or court ordering your Interlock probation it is strongly recommended that you avoid Testing AND DRIVING with any level of alcohol in your body There is a chance that certain alcohol based substances mouthwash cough medicine etc may cause a Test Failure if such innocent substances are still fresh on your breath If this occurs rinse with water and take several deep breaths to make sure the substance in question is thoroughly removed from your mouth before testing again WARNING Attempts to test and start the Interlock vehicle after drinking are considered extremely serious by the Division of Motor Vehicles and other adjudicating agencies and courts Continuous readings of alcohol at any level or detection of high BrAC levels can result in rem
31. ving privileges to certain times of day do not attempt to drive outside those times Depending on the requirements of your State Agency the device will either log the fact that the vehicle is being driven during restricted times or enforce the restriction by activating the alarm Page 13 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Section9 Vehicle Service Mode This section describes how a mechanic can troubleshoot and service your vehicle with the QuicTest Interlock installed If your vehicle needs automotive service your mechanic can troubleshoot and repair it with the QuicTest Installed without having to take Breath Tests 1 Take your vehicle to a State Licensed service mechanic 2 Advise the mechanic that your car is equipped with a QuicTest Ignition Interlock Please inform him that he will have to call the call center at your Service Provider prior to moving or working on the vehicle See number below 3 If your unit requires a PIN to wakeup you will have to give this number to the mechanic SERVICE PROVIDER Monitech Ignition Interlock Systems Customer Support Center 1 800 521 4246 or 919 459 1700 Section 10 Lockout Override Code If your unit has put your vehicle in Permanent Lockout due to an extreme situation Such as a missed Service Appointment due to natural disaster severe weather severe illness etc it may be possible for the lockout date to be temporarily reset remotely
32. vity may be detected and recorded and may result in service charges fines or loss of license WARNING Do not attempt to circumvent the device by starting the vehicle in any manner other than the normal ignition method Do not attempt to remove or modify any wiring or other equipment installed as part of the device installation Doing so may result in service charges fines loss of license damage to the vehicle or electrical shock No other person is allowed to take a Breath Test other than the person intending to drive the vehicle WARNING Attempting to instruct and or allow any person underage or without a valid driver s license to perform the Ignition Interlock Testing Procedure is a direct violation of Program rules and will result in removal of the Interlock and subsequent license revocation As always you should buckle your seat belt and be an alert and courteous driver at all times The life you save may be yours Page 3 of 17 Monitech Interlock Systems QuicTest User Manual Rev A 2 16 08 Section2 QuicTest Sample Head Overview Figure 2 1 Sample Head Front View Figure 2 2 Sample Head Back View 1 Display Window 1 Trigger Button 2 Mouth Piece Port 2 Serial Number 3 Disposable Mouth Piece 3 Mounting Clip 4 Left Back lt lt lt Button 5 Right Next gt gt gt Button 6 Detachable Coil Cord Connector 7 Speaker Ports Section3 QuicTest User Menu Unit Wake Up Under normal circumstances the unit wi
33. w the instructions above Section 5 to take a Breath Test 3 The unit will display PASS WARN or FAIL If the unit indicates PASS WAIT a brief moment until the unit displays OK TO START Attempting to start before this message is displayed even if you passed will result in an aborted start attempt and require another BREATH TEST When the unit says OK TO START start the car as you normally would As soon as your vehicle is started you may begin to drive The display on the unit may say OK TO START for an additional 2 minutes typically 30 seconds and then the unit will display RUNNING To learn more about unit operation and testing requirements as you continue to drive please see Section 7 0 If the unit indicates a WARN This means that a low level of Alcohol has been detected but not enough to fail the Breath Test based on the Fail Level set by your State Agency You will be allowed to start your vehicle however you should understand that if your Breath Alcohol Content BrAC rises as you are driving you may be required to stop the vehicle due to Running Test results to be discussed in a later section before you reach your destination If you choose to start your vehicle WAIT a brief moment until the unit displays OK TO START Attempting to start before this message is displayed will result in an aborted start attempt and require another Breath Test When the unit says OK TO START start the car by turni