SPPL-WB-KO-Specification,Installation and Operation
Contents
1. MANUFACTURING Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS STODDART Specification Installation and Operation Type 1 I nstallation and Operation Manual for Stainless Steel Knee Operated Wash Basins This manual is suitable for the following models Models Knee Operated Wash Basin SPPL WB KO1 Knee Operated Basin Type 1 SPPL WB KO1 300 Knee Operated Basin Type 1 300mm Splashback SPPL WB KO1 TV Knee Operated Basin Type 1 Tempering Valve SPPL WB KO1 300 TV Knee Operated Basin Type 1 300mm Splashback Tempering Valve SPPL WB KO1 300 TMV Knee Operated Basin Type 1 300mm Splashback Thermostatic Mixing Valve SPPL WB KO1 300 TMVE Knee Operated Basin Type 1 300mm Splashback Thermostatic Mixing Valve Enware SPPL WB KO2 Knee Operated Basin Type 2 SPPL WB KO2 300 Knee Operated Basin Type 2 300mm Splashback SPPL WB KO2 TV Knee Operated Basin Type 2 Tempering Valve SPPL WB KO2 300 TV Knee Operated Basin Type 2 300mm Splashback Tempering Valve SPPL WB KO3 Knee Operated Basin Type 3 SPPL WB KO3 TV Knee Operated Basin Type 3 Tempering Valve Please ensure this document is issued to the installing plumber For warranty to be valid installation instructions must be followed Doc ref SPPL WB KO Specification Installation and Operation Revision Date 20 09 2013 Page 1 of 4 STODDART Specification Installation and Operation MANUFACTURING Stainless Ste
2. Circlip 2 Unscrew pushrod 3 press in the valve amp remove the push rod 4 Turn the stop cock off quarter turn in supply side of valve 5 Unscrew the valve cartridge out of the front of the valve body e Inspect the valve seat If dirty identify source of contamination clean the cartridge and the valve body Apply a thin smear of food grade grease to the sealing surfaces amp re install If sealing surfaces are damaged replace the cartridge Warranty does not cover dirt in valves install a line strainer filter to protect the valve SPARE PARTS Article No Description CMPL 0255 Waste and Plug CMPL 0352 Valve Housing complete CMPL 0647 Valve Cartridge 15 30 seconds fitted as Standard CMPL 0353 Valve Cartridge 5 7 seconds alternative spare part CMGE 0510 Spring for Push Basin front panel CMPL 0025 Braided Hose 300mm CMPL 0413 Gooseneck Spout used in SPPL WB KO1 CMPL 0438 Domed SS Bubbler used in SPPL WB KO2 CMPL 0464 Wall Spout used in SPPL WB KO3 CLEANING INSTRUCTIONS All surfaces of the product should be cleaned with mild soap and water or a neutral product Carefully rinse away all surplus cleaning product IMPORTANT Never use harsh or abrasive cleaners on stainless steel Do not use chlorinated or bleach water CUSTOMER I NQUIRY All customer inquiries regarding Stoddart Stainless Steel Wash Basin s should be referred to Customer Service Department Stoddart Manufacturing 39 Faisal Hatia W
3. 673 85mm above FFL for 900mm basin height Attach bracket to the wall with sufficient load bearing fasteners Slide the wash basin on to the bracket amp replace the screws on either side of basin Ensure water lines have been thoroughly flushed before connecting to valve Connect supply to valve inlet Replace access panel KO2 amp KO3 Clean stainless steel surfaces Note Protect the product at all times by wrapping in plastic until all other work is complete Note Warranty does not cover dirt in valves install a line strainer filter to protect the valve SAFETY PRECAUTIONS e For the installation and operation observe all relevant electrical plumbing and building standards TROUBLESHOOTING Water does not switch off or water continues to run from outlet after timed out Check Front panel has some free play Make sure there is a 2mm gap between push rod and push panel valve must be able to travel freely to fully close if not adjust push rod Check that a line strainer or filter is installed amp is clean o Ifa line strainer is installed amp has contaminants present could some have got through to valve seat Check Valve Cartridge o Ifa Line strainer is not installed check for dirt and grit in valve cartridge f above checked out o k contact service Note cartridge is a service part amp not covered by warranty if damaged by dirt in water Stoddart Recommend Customers install a line strainer filte
4. aim should be filed with carrier if appropriate RESPONSI BI LI TI ES Stoddart thoroughly inspect all products they are despatched from our factory Stoddart Manufacturing will not accept responsibility for shipping damage The Plumber is responsible to ensure that the system is installed in accordance with all specific requirements of local codes and regulations including AS 3500 If questions or complications should arise during the installation of a Stoddart product that cannot be solved using the accompanying instructions please contact our offices or local representatives Note It is the Plumbers responsibility to install this product in accordance with AS3500 REFERENCED AUSTRALI AN STANDARDS Design amp fit out of Food Premises AS 4674 2004 Markings amp Labels Watermarked components must have Watermark logo and AS 3500 1 2003 license AS 5200 000 2006 Appendix B Copper alloy products marked DR AS 6400 2005 Clause 2 4 6 AS 2345 2006 Dezincification resistance Dezincification resistance applicable to copper alloy AS 2345 2006 components in contact with mains water Australian Standard for the pipe or fitting Joints i e Spigots sockets flanges Dimensional compliance with relevant or corresponding AS 3688 2005 other joint components where Australian Standard for the pipe or fitting interfacing other authorized Pipe Threads of Whitworth Form Part 2 Fastening Pipe components Threads Installatio
5. ay Karawatha 4117 Brisbane Queensland Australia Ph 61 7 3440 7602 Fax 61 7 3344 1000 Email plumbing stoddart com au Web www stoddart com au Doc ref SPPL WB KO Specification nstallation and Operation Revision Date 20 09 2013 Page 4 of 4
6. el Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS CONTENTS RECOMMENDATION seccceeceatectecnstesmecantacvacis dossecante E A E EAE E E E E 2 RESPON sil Ti ES ar aa mec weeks untae igen cee etait 2 REFERENCED AUSTRALIAN STANDARDS eset carta eset sect sede tne enc ab ari tap stoning sagen tie EEEREN ae 2 INSTALLATION OF KNEE OPERATED WASH BASINS sa cicsvsrsasvscvsnseocnessvuenaesenaners sexta eres aaenncesssiuaentceenendeusauseseeenaereisanundersiaects 3 Water amp Waste RSC IIT Seige cacststgnyacatsctae anne gansragetycucuncatecustan at uaustince satsnlaee uatistoe at uct atretuatoebiegtuctatsc gee esl ceeueateceayeciew 3 Installation of Knee Operated Wash Basins wesasctsccssncteccnsts beuaasnatenndameianasateGunalsieaanycaauahsnresacueheathateecatnatsecaincutanmare 3 AFETY PRECAUTION aaa E a 3 TROUBLESHOOTING arrea E E E E ere ene 3 IG TREV AL E osrin an oa er E E I A E E E E E E E E aeueteaseneeiasass 4 SPAREPART errre E E E A E E 4 CLEANING HIS TRUCT FONG caecum stunsceevicneseat cerns ener cute ee eee ee ee eee 4 CU OIE ROU ceceareners cae Gunvgauseeayeccye eae E eee recurs ere gee eee race ere nee eereae 4 RECOMMENDATIONS Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A cl
7. n Warranty Installation instructions shall be provided by AS3500 2 2003 the manufacture Doc ref SPPL WB KO Specification nstallation and Operation Revision Date 20 09 2013 Page 2 of 4 Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS STODDART Specification Installation and Operation MANUFACTURING INSTALLATION OF KNEE OPERATED WASH BASINS Water amp Waste Requirements s Flow pressure 300kPa 500kPa 7 Max static pressure 800 kPa Min supply connecting pipe size 15 mm Removable Waste is 40mm Trap provided by others avon Pipe work to the valve fixture must be sized to and installed to water service rules and regulations arawa AS NZS 3500 1 and local regulations To ensure proper sizing of the pipe work it is recommended to engage a qualified hydraulic designer Fixed Installation of Knee Operated Wash Basins moyana All Stoddart basins are supplied with mounting holes pre punched for easy installation e Remove the packing from the wash basin and check for damage e Remove access panel e Unscrew the screws on either side of the basin to remove the removable galvanised bracket from the basin e Place the bracket at desired height and mark the locations of screw holes and or outline around the bracket if adhesive is being used making sure bracket is level e Ensure the water supply and waste are in the zone marked in the image to the right and the waste is approximately
8. r to protect the valve Water runs for too short or too long AS4676 requires min 15 seconds for hand washing CMPL 0647 is designed to run 15 30 secs Make sure there is a 2mm gap between push rod and push panel amp rod slides freely o If gap it too big valve might not get pushed in fully giving short cycle o If rod doesn t slide freely it may cause the valve to take longer to time out Check position of circlip on valve spindle inner short outer long Check water pressure low water pressure longer time Check turn stop valve in inlet of valve Partially closed may slow time Water flow from outlet is too little Check supply pressure and stopcocks are open Check lines are not flattened or kinked Water leaks onto floor under basin e Check plumbing connections tighten as required e Check seal between spout and basin replace seal or apply silicon sealant e Check valve spindle valve stem seal replace faulty cartridge 900 a V Zone for plumbing in and 900 waste height FFL i eae m a 1 ee Mr of bracket 668 to waste 848 to top Doc ref SPPL WB KO Specification Installation and Operation Revision Date 20 09 2013 Page 3 of 4 MANUFACTURING Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS STODDART Specification Installation and Operation SERVI CI NG THE VALVE e 1 Remove