Home
Quick reference guide WZ FSE 2-2
Contents
1. 3 Putting into operation 3 1 Basic mode when the unit has been switched on see manual WZ FSE 2 2 3 2 Memory selection at the user interface see manual WZ FSE 2 2 12 4 Settings 4 1 Software commands Com Value range Description See mands chapter in user manual IN ASCII 16 digits Output of the serial number of the unit 512 0 1 Echo of the commands X 0 gt no echo X 1 gt echo Output mode X 0 gt normal X 1 gt extended service command Output of all the information about the 32 memories T R P Output of the information about a single memory T R P 13 Com Value range Description See mands chapter in user manual SMX Software selection selection of the memory and the relevant TX RX channels and the power level X 0 31 Setting the number of the memory for TX RX and PX command X 0 2518 eae a new transmit channel on the selected memory gt KX eae a new power level on the selected memory gt KX Output of the current TX channel number service command Output of the current RX channel number service command ll RX X 0 2518 qe asta a new receive channel on the selected memory gt KX Value range Description See chapter eae of the current power level service command in user manual Output of the number of the current memory service command Output of the analogue RSSI signal input level ras protocol X
2. 0 gt switch off 1 gt switch on lt lt Restoring the factory preset Tabelle 4 1 Overview of the commands Hardware selection selection of the memory and the relevant TX RX chan nels and the power level depending on the hardware setting connection of the inputs SELO SEL4 pins 12 16 4 2 Calculating the channels and frequencies Frequency MHz Start frequency MHz Channel spacing MHz Channel Channel offset Frequency MHz Start frequency MHz Channel Channel offset Channel spacing MHz Equation 4 1 General formulas for calculation of the channels and frequencies Channel Channel Start Stop Channel range spacing frequency frequency offset WZ FSE 2 2 0000 1399 0 0200 MHz 146 0100 MHz 173 9900MHz o 1400 2518 0 0250MHz 146 0250 MHz 173 9750 MHz 1400 WZ FSE 2 2 HK 0160 2000 0 0125 MHz 137 0000 MHz 160 0000 MHz WZ FSE 2 2 UK 0000 2400 0 0125 MHz 165 0000 MHz 195 0000 MHz Table 4 2 Overview of the specific parameters of the relevant unit for calculating 16 5 Troubleshooting 5 1 Messages in normal output mode The WZ FSE is connected to the terminal program via serial interface Command is valid and has been executed correctly ERROR Command is valid but could not be executed correctly CMD ERROR Command is invalid Table 5 1 Normal output mode E0 17 5 2 Messages in extended output mode T
3. Quick reference guide Radio unit for voice and data transmission in the 2 m band Safety precautions A Please note e The units are not suitable for operation in rooms with an explosive atmos phere as well as damp environments or in rooms with aggressive air or increased electromagnetic requirements e Mind the instructions for putting into operation e Both the casing and the antenna may become very hot you may get burned during sending operation Provide for sufficient cooling and air circulation e Installation of the antenna needs to be in accordance with the valid regula tions and requirements for protection of human beings within electroma gnetic fields e Avoid to touch conductive parts of the device e Do not open the device yourself only permit repairs by the manufacturer ESD protection measures Comply with the ESD protection measures according to DIN EN 61340 5 1 2 when opening the unit potential equalisation between body and ground of the unit via high value resistance approx 1 MOhm e g with a usual wrist band Read the user manual carefully to be able to use the wealth of features of your new WZ FSE 2 2 You can find further information about this topic on our website http www fmncom com Information regarding the used trademarks Microsoft and Windows are registered trademarks of the Microsoft Corpora tion All the other trademarks and product names are trademarks or registered trademark
4. ernet www fmncom com Subject to change WZ FSE 2 2 Ka8402 0024 320 001 Edition No 10 06 1112 0757
5. he WZ FSE is connected to the terminal program via serial interface Message Value range Description OK Command is valid and has been correctly exe cuted CMD ERROR Command is invalid TX OK Programming of TX channel was successful PWR OK Programming of power level was successful ERROR XX XX 00 FF Command is valid but has not been correctly executed RX OK FP Programming of RX channel was successful RX ERROR XX XX 00 FF Error when programming the RX channel TX ERROR XX XX 00 FF Error when programming the TX channel Error PWR XX 00 FF when programming the power level ERROR XX Table 5 2 Extended output mode E1 18 6 Conformity The FMN communications GmbH declares that the radio unit WZ FSE 2 2 complies with the basic requirements and the other relevant provisions of the directive 1999 5 EG R amp TTE directive The WZ FSE 2 2 can be operated in the countries of the European Union EU Out side of the EU apply the national regulations of the relevant country The complete declaration of conformity can be found and downloaded on our website http www fmncom com gt E 2 f e O 19 For the sake of the environment Waste paper content of 100 E FMN communications GmbH Grimmelallee 4 99734 Nordhausen Germany P O Box 10 04 65 99724 Nordhausen Germany Phone 49 36 31 56 34 41 Fax 49 36 31 56 32 24 Email info fmn de Int
6. s of the relevant company Copyright All rights reserved Duplication of these instructions for use or parts thereof by any reproduction method whatsoe ver is not permitted without prior permission of the manufacturer Amendments may be published without prior notification Notwithstanding the above declaration the manufacturer accepts no liability for errors in these instructions or their consequences 1 General instructions In order to be allowed to operate the radio unit you must apply for a license at your local authorities and they will assign you a frequency All connection cables have to be equipped with an earth connected shiel ding The connection cable for the antenna has to be equipped with a wave impe dance of 50 2 The manufacturer recommends to mount devices in printed circuit board version into a metal housing Corresponding mechanisms are to be used for the detection of single bit er rors during a data transmission e g protocol with creation of check sum Only use antenna designated for the frequency range Failure to observe this instruction will cause the approval to expire and may result in legal action The connected antenna has to be tuned to the working frequency of the ra dio set to get a maximum range The use of an antenna that has not been tuned can lead to destruction of the radion unit Provide sufficinet cooling e g a heat energy of about 30 W has to be elimi nated in case of a
7. transmitting power of 6 W Further troubleshooting can be necessary in case of operation e g at switching power supplies The compliance with the instructions for use and for putting into operation also belongs to the intended use Every other use is considered to be not intended The manufacturer accepts no liability for any damages resulting from such other use Y 9 _ S gt ba 72 E i Y i 2 General product description 2 1 Designation of the function elements Pin20 Pin4 Pin1 User interface Power supply Figure 2 1 Designation of the function elements 2 2 Interfaces of the radio unit 2 2 1 Pin assignment of the power supply The pins are assigned as follows Pin designation at the socket Voltage supply 10 8 15 6 V DC Voltage supply 10 8 15 6 V DC Table 2 1 Pin assignment of the power supply 2 2 2 Pin assignment of the user interface for analogue peripherals Assignment Function i ass founsa moo Int anos _ we AUDIO Input digital DATA DATA_IN Input analogue Output analogue 10 GND Input digital 1 1 DATA_OUT Output analogue pines restos ak sce ck OJJA w RS232 OUT ERROR 2 2 3 Pin assignment of the user interface for digital peripherals FFSK or GMSK modem Input digital RS232 20 ER UET RS232_OUT