Home
User`s Manual - IBS-01e
Contents
1. p TROUBLE SHOOTING 1 Check whether the AC adapter is properly connected 2 Check if the AV signal cable or USB cable is well connected 3 Check whether the lens is locked to its right position Make sure if the lamps inside the lens is light 4 Connect the unit to another monitor to judge the unit or monitor is out of order to repair it Take off the lens you can blow out the dust by using a small air pump or wipe the small glass of the camera inside the handy probe with a cotton bar Please hold the handy probe toward ground direction to avoid new dusts If the camera gets mildewed under humid condition please contact the engineer to clean it Please adjust following buttons of the monitor 1 TINT 2 SHARPNESS 3 BRIGHTNESS 4 COLOR Its because you do not rotate the black rubber ring to the bottom of its direction So some light is covered or some light is opened You should completely rotate the black rubber ring of the polarized lens anti clockwise or clockwise 12 CONNECTION TO PC 1 USB Video Image Driver Wbvidcap System requirement a IBM compatible PC b CPU P4 with 40G HDD 1 6GHz or up c RAM 512M or above Required OS Windows XP or Windows VISTA or WIN 7 amp 8 1 Installation of Wbvidcap Remark Do not connect the scope to PC while USB driver is not well installed The USB Driver and Application for Digital Microscope IBS 01e for Windows 1 Pow
2. amp step 3 to let all computer USB ports useful under scope connection 2 Step 2 When the computer recognizes the scope signal monitor screen corner will appear a hint Find New Hardware Wizard After searching for several seconds there will continuously appear the following small windows Please operate as per the instructions Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for MicroScope Video Capture If your hardware came with an installation CD or floppy disk insert it now Found New Hardware Wizard Please wait while the wizard searches 17 Hardware Installation A The software you are installing for this hardware MicroScope Video Capture has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Completing the Found New Hardware Wizard The wizard has finished installing the software for MicroScope Video Capture Click Finish to close the wizard Till now MicroScope Video Capture has also been found 18 3 Step 3 Now the MicroScope Video Capture has been foun
3. of USB and Beauty Scope When you are using USB cable to connect the Microscope unit and PC the operation procedures are as follows 1 Make sure the USB cable has been well connected to USB output of Microscope unit and the USB port of PC 2 Power on Microscope unit 3 Click Start All Programs folder folder Wbvidcap Then the image can be observed from PC monitor A CONNECTION A 1 Image size When you are observing the image the image size is possible to be 640 x 480 or 320 x 240 You can click the Option button Video Format to change the image size to be your desired 320 x 240 or 640 x 480 Please refer to the following drawings Sequence Preview Frame Rate v Microsoft WDM Image Capture Win32 Version 5 1 2600 0 E Set the image dimensions and format 21 Image size 640 x 480 Image size 320 x 240 22 A 2 Video Source selection amp Color adjustment If you want to select correct video source or adjust your preferable colorful image you can click Option button Video Source Video Source selection After clicking Capture Source you should select the correct video capture source to be MicroScope video Capture Click Apply and then OK and confirm the setting 23 Color adjustment After clicking Device Setting you can change the brightness contrast sharpness etc to your desirable value Click Apply and t
4. As you can see you can get freeze image from the window There are 3 ways to capture image a Press Enter b or press space key of the keyboard c or press Freeze under Capture options 2 When you get freeze the image the image will automatically enlarge to as large as the screen height allowed When you press Enter the image will return to the original size 28 3 You can also save the image in jpg or bmp types MTS 4 V f 24 TA ez gt a M 242 E A RUM 4 E p 2 T s L4 p P i k Non 5 Y wd s fe O s Magny JES 4 Please save the image to your assigned folder and input the file name and you can also select the original size or max size to save the image Save in E My Documents ex E3 o E Pictures My Recent Documents Operation under other environments The above is just one of the operation examples under New KOWA camera image capture program If you have other image software such as Photoshop Photolmpact or Scanner driver software in your computer you can also get image and save picture under any image software environment 29
5. IBS 01e Easy Beauty Scope SKIN amp HAIR ANALYSER USER S MANUAL Version 3 May of 2014 USER S MANUAL Congratulations on your purchase of Easy Beauty Scope We believe the versatility and ease of use of this product will lead you to obtain more success in business deals and create more profit for you The Video Microscope is guided cool light surrounding the lens and automatically provides the best illumination to enable you to obtain the optimum viewing angle and colour of the target object on the TV or computer monitor Image retention on hard copy and image storage are possible by simply connecting the video output of Easy Beauty Scope directly to an optional Color Video Printer Video Tape Recorder VTR or USB output to Personal Computer Laptop 1 ACCESSORIES 1 1 Standard accessories ITEM DESCRIPTION 2 1 Handy probe with camera resolution 3 000 000 pixels Probe stand AV signal cable RCA RCA video cable USB cable USB driver CD amp New KOWA camera image capture program s s Poveraseper 0020 1 2 Optional accessories IBS 01 Lens 1x focus adjustable for full face body half body partial face Sie tlogy Lens BSSORNUN Lanes UV polarized acne specion _ a BX002A Black carrying case Pro Capture software for history skin hair iris microcirculation database comparison amp customer management system 11 Kowa Ma software for
6. ORN UV lens the acne will appear in fluorescent brown or red color It is very useful in observation 6 Iris lens for iridology analysis The focus range for this lens is adjustable You can rotate the black ring clockwise or anti clockwise to get the right focus of the iris image Anti infection cap please attach The operation of iris diagnosis it on the top side of the lens 7 Microcirculation lens for observing the thickness shape of the blood vessels the speed of blood flow of the nail tip a Suggested test part left ring finger see the picture for available area Available test area b Operation method Please apply penetrating oil vegetable oil on the test part in order to get clearer image Method 1 Hand hold operation Method 2 Easy stand operation You can hold the handy probe You can also fix the handy probe contact the lens to the available on a stand adjust the working area of left ring finger distance to get right focus amp clear Refer to operation in next page image 10 320x Microcirculation Lens Application 1 Standard package 1 Finger supporter Probe stand 1 pc 2 320x Microcirculation lens X 1 pc 3 Empty bottle lt 1 pc Please add vegetable oil 4 Slope plate to adjust finger height X4 pcs X Optional Pro Video Master program which gives good image capture amp video recording for microcirculation condition observation 2 Usage of F
7. d Please wait for 5 seconds and monitor screen will continuously appear some small windows Please operate as per the instructions Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for MicroScope Bulk Device 1 If your hardware came with an installation CD lt lt or floppy disk insert it now What do you want the wizard to do Found New Hardware Wizard Please wait while the wizard searches 339 MicroScope Bulk Device 19 Hardware Installation AN The software you are installing for this hardware MicroScope Bulk Device has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing STOP Installation Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for 39 MicroScope Bulk Device Click Finish to close the wizard Till now MicroScope Bulk Device has also been found Reminder Please execute the same procedures in step 2 amp step 3 to let all computer USB ports useful under scope connection 20 3 Connection Usage
8. er on your IBM compatible PC Insert the USB Driver CD R uu into the CD ROM drive TWAIN Driver XP and VISTA 2 The CD R will auto run Or click i My computer CD ROM Setup exe 3 Click USB Driver and Application Preparing to Install 4 Follow the instructions to MicroScope Setup is preparing the InstallShield Wizard which will guide you through the program setup process j nsta the setu p p rog ram Please wait Extracting ISSetup dll BRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR 13 The InstallShield Wizard will install MicroScope Viewer into your computer We strongly recommend you to exit all active WINS programs pior to running this setup 4 1 Click Next Click the Cancel button to quit this setup and close any active programs Click the Next button to continue Please select the software components you want to boxes below Press the Next button to continue or press the Back button to previous step 4 2 Click Next The driver allows the MicroScope communicate with your computer InstallShield 4 3 Click Next Instalishietd 14 The setup program is ready to start copying the program files Click Next to begin this operation if vou are sure about the settinas Current Settinas MicroScope Driver 4 4 Click Next Setup Status MicroScope is configuring
9. hen OK and get your desirable color image If you want to change back to the original color setting you can just click Default and then OK to get the original color image 1 B DISCONNECTION B 1 If you want to leave Wbvidcap operation close Wbvidcap window firstly and then power off Microscope unit B 2 If you want to return to AV output a Close Wbvidcap operation release the USB connections b Complete the AV connection between Microscope unit and TV monitor c Re power on the Microscope unit and the image will be seen from the TV monitor Notice When Microscope unit is working with PC under Wbvidcap driver the output of AV signal will be shut down automatically 24 Il TWAIN Driver Wcam only available on 32 bit PC 1 Why shall we install WCam of TWAIN driver Answer The original USB driver of this Microscope unit only provides you to get the image picture If you want to save the picture you should install WCam of TWAIN driver 2 Installation of WCam Remark a Please make sure the USB driver of this Microscope unit has been well installed b Please do not make any connection between Microscope unit and computer before software installation 2 1 Power on your IBM compatible computer 2 2 Insert the USB Driver CD R disk to CD ROM drive 2 3 Then you can follow the instruction on the USB Driver setup screen to continue the installation process 2 4 Click on TWAIN D
10. inger supporter Put the testing finger inside the supporter Please insert the slope plate in the supporter You can move the testing finger backward amp If the finger is thicker the slope plate might forward to find the best view position be unnecessary Ref 3 Operation of microcirculation inspection 3 Operation of Microcirculation Inspection zx a Please apply vegetable oil on the Hold IBS 01e handy probe with You can get right focus amp clear finger suggested test part left ring 320x lens contact the lens to image by adjusting the probe in finger just near to the nailfold oil the applied area a slight slope or moving finger applied area about 1cm backward amp forward 4 The operating position between the operator amp the tested 5 Put the handy probe back to probe stand Please hold the handy probe in a parallel direction of the tested finger then the microcirculation image will be in forward direction to facilitate the microcirculation shape and dynamic observation The monitor is powered on but the handy probe doesnt work the handy probe cannot offer light or image How to clear if there are dust pots on the camera of the handy probe How to adjust when the image color is out of harmony While using the polarized lens to inspect surface skin or deeper layer skin why the lower part of the screen becomes darker or brighter TROUBLE SHOOTING
11. onitor to ON position 4 2 Lens with a contact type illumination head is intended to be placed on or held just above the viewing object Then you will get a vivid image on the monitor 5 SINGLE FREEZE FUNCTION OPERATION TV MODE Freeze button Press the freeze button live picture frozen picture live picture 6 OPERATION OF OPTIONAL LENSES 1 50x Polarized lens You can rotate the black rubber ring anti clockwise to make surface skin inspection rotate the black ring clockwise you can make deeper layer skin inspection inspection 2 Normal 50x and 200x lens The lens has been well adjusted the focus You can slightly contact skin or hair for image capture 3 1x focus adjustable lens for styling purpose The focus range for this lens is adjustable You can rotate the black ring clockwise or anti clockwise to get the right focus of full face body half body or partial face This lens does not consist any inside LED lamp therefore getting enough environmental outer light source is required 4 650x lens for hair cuticle inspection The focus for this lens is adjustable You can rotate the black ring clockwise or anti clockwise to get the right focus to inspect the hair cuticle Ww 5 5ORN UV lens This lens is specially designed for ACNE inspection It needs to be applied under Pro Video Master software Under the UV light of 5
12. river The USB Driver and Application for Digital Microscope IBS 01e for Windows XP and VISTA USB Driver and Application User s Manual NEW KOWA WE 25 2 5 The program will run automatically WCam300 For WinXP Driver V1 0 P D LI S Copy CAWINNTATWAJN 32Wwcam300drvpcam 2 6 Click on OK to restart the computer To complete the installation the system must be restarted WCam300 For WinXP Driver V1 0 Installer x This system must be restarted to complete the installation Press the OK button to restart this computer Press Cancel to return to Windows without restarting 26 Ill New camera Image capture program Remark a This program can help you to capture and save images Please make sure the USB driver amp TWAIN driver have been well installed b Please also connect the USB cable between Microscope unit and computer and power on the unit c You can directly click New KOWA camera and it will be moved to the main screen desk of PC The USB Driver and Application for Digital Microscope IBS 01e for Windows XP and VISTA USB Driver and Application TWAIN Driver User s Manual Now you can go to the main screen desk of PC please double click New KOWA camera icon to enter the window da c HAES ACDSee 7 0 995 m DESEE PAX ANEW KOWA Lamers a TES EM Intemet Explorex 2f 1
13. skin hair image store before after comparison amp customer management system 12 Pro Video Master software for image store video recording before after comparison amp customer management system 2 SYSTEM BLOCK DIAGRAM Power adaptor for Video output for RCA connecting to DC Phone jack connecting input of the unit to monitor s video input USB port for i PC connection Adaptor on Adaptor off qeeeesosesesesesosesesesesesesesesesesesosesosesosesosesosesesesssesssssesssssssessosososososososesosososososososososososososssososososososososssososososososososossososososososososososososososososssosososcsssesosesosesescsesescscscscscsescssososooo When you are connecting the unit with TV please make sure AV signal cable s connected and use on off switch to power it ON or OFF e When you are connecting the unit to PC please make sure USB cable is connected and set the switch to ON 3 ATTACHING LENS TO HANDY PROBE 3 1 Attaching lens to handy probe 1 Take off the anti dust cover of the handy probe 2 Find the short post on the lens F 4 Match plug in the post to the shape slot to ensure they fully combined Turn clockwise to screw on the lens anti clockwise to screw off the lens 4 OPERATION 4 1 Complete the installation in accordance with the system block diagram Turn the power switches of both the unit and your TV m
14. your new software installation 4 5 When the setup is finished PC will automatically execute the next procedure 4 6 Select Yes want to restart my computer now and then Click Finish The TWAIN driver Installation is complete Setup has finished installing MicroScope on your computer to restart my computer now I wil restart my computer later 15 5 The computer is restarting to add this Wbvidcap driver in PROGRAM system 6 To make sure Wbvidcap driver is setup Click Start icon All Programs folder MicroScope folder Uninstall Wbvidcap Internet 7 My Documents Internet Explorer La E mail 2 My Recent Documents gt Outlook Ex press 2 MSN Explorer Windows Media Play Q Windows Movie Make 9 Startup e Tour Windows XP Internet Explorer A Files and Settings rr MSN Explorer Wizard M Outlook Express y Remote Assistance D Windows Media Player All Programs 3 Windows Messenger 16 2 Steps of hardware installation 1 Step 1 When the computer is restarted please connect the scope as per the following instructions and power on the scope 1 1 Please plug the USB cable one side to scope and the other side to any USB port of the computer 1 2 Make sure the scope is powered on and wait for 5 10 seconds to let the computer recognize scope signal 1 3 Please execute the same procedures in step 2
Download Pdf Manuals
Related Search
Related Contents
Adenda No1 Graco 3A1940G User's Manual Elexsys E 500 User`s Manual: Basic Operations CFM TEK250H-V2 User's Manual Copyright © All rights reserved.