Home
the user manual
Contents
1. Warranty limitations and exclusions Dhama Innovations makes no express warranties beyond those stated here Dnhama Innovations disclaims and excludes any other express or implied warranties not set forth in this Limited Warranty including but not limited to warranties of merchantability or fitness for a particular purpose All express and implied warranties are limited in duration to the limited warranty period No warranties apply after that period This Limited Warranty excludes liability for any personal injury property damage or special incidental or consequential damages arising out of related or incident to use the product even if Dhama Innovations has been advised of the possibility of such potential loss or damage unless state law otherwise precludes this exclusion CeO O sso 3 eee CLIMA R Cryothermic esse WARE Wrist Wrap A Multi dimensional Innovation in Wrist Hand Orthotics with patented cold hot amp contrast therapy USER MANUAL Caution A Federal law restricts the sale of this device by or on the order of a licensed healthcare WASHCARE STORAGE amp MAINTENANCE Apart from the cleaning instructions mentioned in this section the user should perform no product maintenance If the user performs maintenance or tampers with the device this will void the warranty and any product liability If your CLIMAWARE Cryothermic Wrist Wrap requires maintenance please contact CL
2. 20 minutes session may cause possible heat cold burn A Caution Warning related to product usage e Exercise extreme caution while using the highest level of cooling heating contrast therapy to avoid injuries and burns e Forheat therapy application it is recommended to use Moist Heat Pad at the High level to avoid heat burn e Donotuse the product while charging e If removing the product in between use first remove the product from the body then turn the Touch Controller Battery Unit OFF e Never try to insert the charger power cord male connector into the battery output point This will damage the control unit permanently e Never operate the system with damaged cables or connectors or other mechanical damage or if the unit is otherwise not fully operational e Do not use any charger adapter other than that provided by CLIMAWARE Rx Cryothermic Wrist Wrap Use of other chargers may result in electrical shock and will void the warranty thereby voiding any product liability e Donot short circuit the Touch Controller Battery Unit e Do not use the product and Touch Controller Battery Unit while smoking or near flames ignition e Donot wet or submerge the Touch Controller Battery Unit in water e The Touch Controller Battery Unit may explode if damaged or exposed to fire do not expose to high temperatures or direct sunlight for long periods of time e Donotdisassemble crush strike or puncture
3. Battery Unit offers three adjustable levels of cooling heating contrast therapy Touch the desired level to activate the same In all three levels Cooling mode is indicated with Blue LEDs and the Heating mode is indicated with Amber Orange LEDs Low Lowest level of cooling heating contrast therapy Medium Medium level of cooling heating contrast therapy High High level of cooling heating contrast therapy FON Med High Auto cut off In both Manual and Auto Mode the system cuts off on its own after 20 minute session Study of scientific literature suggests that exposure to cold hot temperatures for more than 20 minutes at a stretch can be harmful to tissue health Therefore we have taken special care in our design to make the device cuts off on its own After the cut off you need to restart the system by sliding the power ON OFF button Cold Heat Manual Mode This is a toggle button used in the Manual Mode Touch this button to activate cooling or heating By default cooling is selected A touch again will change the mode to heating and so on Touch the appropriate temperature level button to select the desired temperature level As a safety measure the device is specially programmed to shut down automatically in a gradual manner to minimize the risk of cold heat burn After the 15 minute of the 20 minutes session the temperature levels automatically decreases from higher to lower level at a gradual interv
4. to 180 F for 10 minutes Warning The temperature of the pre heated water used for sterilizing the Wrist Wrap should never exceed 180 F This can damage the Wrist Wrap Up to 10 cycles of sterilization are permitted e Hang to dry both the inner and the outer sides of the Wrist Wrap wy oo mM X N Hand wash only Donotwring Do not iron Do not bleach Do not tumble dry WARNING PRECAUTIONS and SAFETY INSTRUCTIONS related to CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit You must read these safety instructions and warnings before using or charging the Touch controller Battery Unit Lithium Polymer batteries are volatile Failure to read and follow the below instructions may result in fire personal injury and damage to property if charged or used improperly Neither Dhama Innovations nor our retailers assume any liability for failures to comply with these warnings and safety guidelines By purchasing the CLIMAWARE Rx Cryothermic Wrist Wrap and Touch controller Battery Unit the buyer assumes all risks associated with lithium batteries If you do not agree with these conditions return the complete unit immediately before use e CLIMAWARE Rx Cryothermic Wrist Wrap must always be used with the Touch controller Battery Unit and chargers provided with the specific product kit by the company Failure to do so may lead fire which may result in personal injury and property damage Unauthorized part subst
5. E Rx Cryothermic Wrist Wrap Touch controller Battery Unit e Do not disassemble crush strike puncture drop throw wet or immerse into water the CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit or the battery charger Failure to comply with this requirement may adversely affect the product performance thereby voiding any product liability e Do not short circuit the external contacts on CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit or the Battery Charger e If the CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit has swelled up and or has leaking fluids do not touch any fluids Dispose it immediately according to state regulated norms Discard the battery unit in a state approved battery collection container Disposal This symbol means that this product must not be disposed off with your household waste To learn where to drop off your electrical and electronic waste please contact your local city municipal waste disposal service office You can dispose of the CLIMAWARE Rx Cryothermic Wrist Wrap and Touch e controller Battery Unit in accordance with national legal requirements practitioner Follow the recommendations of your healthcare practitioner regarding the frequency and duration of use The device is intended to be used by or on the order of healthcare professionals in hospitals outpatient clinics athletic training settings or home settings D
6. IMAWARE Customer Service from the U S call at 305 252 9076 from outside the U S call at 91 888 555 0635 or write to info dhamainnovations com Storage e Unplug the CLIMAWARE Rx Cryothermic Wrist Wrap Battery control Unit Touch controller Battery Unit from the CLIMAWARE Rx Cryothermic Wrist Wrap body and turn it OFF before storing it Make sure that the CLIMAWARE Rx Cryothermic Wrist Wrap is completely dry before storing in order to minimize the formation of mildew Store the CLIMAWARE Rx Cryothermic Wrist Wrap and particularly the CLIMAWARE Rx Cryothermic Wrist Wrap Battery Unit in a cool dry and safe location preferably inside the packaging box provided by the manufacturer You can use the carry bag provided with the kit if you want to carry the product onthe move Ensure that the CLIMAWARE Rx Cryothermic Wrist Wrap Battery Unit is charged at least for half an hour before it is stored unused for a long period more than a month of time Empty the Water Feeder Bottle to ensure it is dry before storing it to minimize formation of mildew Remember that your CLIMAWARE Rx Cryothermic Wrist Wrap is a valuable piece of equipment and should be treated with great care Storage temperature conditions 10 C to 24 C 50 F 75 F Relative Humidity less than 50 humidity Storage Warning e Donotkeep store in extreme temperatures above 120 F or below 33 F e Donotleaveina hotor freezin
7. WARE Rx Cryothermic Wrist Wrap or any of its parts and accessories into a microwave oven washing machine or dryer Do not use abrasive materials to clean the CLIMAWARE Rx Cryothermic Wrist Wrap and doing so will void your warranty and any product liability Ensure that the CLIMAWARE Rx Cryothermic Wrist Wrap is completely dry before using it again after wet washing Do not use a fabric softener Washcare For cleaning use a soft brush to remove the lint from the surface of the CLIMAWARE Cryothermic Wrist Wrap If wet cleaning is required Disconnect and remove the CLIMAWARE Rx Cryothermic Wrist Wrap Battery control Unit Touch controller Battery Unit from the CLIMAWARE Rx Cryothermic Wrist Wrap by taking it out from the battery slot Keep the CLIMAWARE Rx Cryothermic Wrist Wrap male connector away or cover it with plastic while washing You can wipe the main body of the CLIMAWARE Rx Cryothermic Wrist Wrap with a wet cloth or You can hand wash the CLIMAWARE Rx Cryothermic Wrist Wrap by dipping alternatively in cold water and mild soap solution or For disinfecting you can use Oxivir wipes or Oxivir sprays You can also dab a small quantity of Oxivir disinfectant cleaner on a sterilized cloth and use it to clean the main body of the wrap Hang to dry both the inner and the outer sides of the Wrist Wrap You can sterilize the main body of the wrap by soaking it in water pre heated
8. WARRANTY POLICY CLIMAWARE Rx Cryothermic Wrist Wrap and Touch controller Battery Unit Dhama Innovations warrants that the CLIMAWARE Rx Cryothermic Wrist Wrap if properly used will be free from defects in material and workmanship This is a limited warranty valid for a period of one year from the date of product purchase This excludes CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit and the AC Adapter the warranty for which is 90 days from the date of purchase If CLIMAWARE Rx Cryothermic Wrist Wrap which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty Dhama Innovations at its option will e Repair the CLIMAWARE Rx Cryothermic Wrist Wrap or e Replace the CLIMAWARE Rx Cryothermic Wrist Wrap with another CLIMAWARE Rx Cryothermic Wrist Wrap The replaced product might slightly vary in color and design as per the currently running model This limited warranty and any implied warranties that may exist under state law apply only to the original purchaser of the CLIMAWARE Rx Cryothermic Wrist Wrap and are non transferrable Extent of limited warranty This warranty does not apply if this product 1 was not purchased from Dhama Innovations or its authorized distributor 2 has been altered in a way or 3 has not been used in accordance with Dhama Innovations Instructions for Use This limited warr
9. al before the system turns itself OFF automatically During this 5 minutes span of automatic safe shutdown mode the temperature levels cannot be changed Auto Mode contrast therapy There are two therapeutic pre programmed Auto mode options installed in the system These Auto mode options allow for automatic alternation between cooling heating cycles at pre programmed time intervals The Auto Mode button is a toggle button Press once to select Auto Mode 1 Green LED press again to select Auto Mode 2 Yellow LED Press again to exit Auto mode After selecting the desired Auto mode option adjust the temperature level button to select the desired temperature Auto Mode 1 Green LED 4 minutes cooling and 2 minutes heating for 15 minutes Auto Mode 2 Yellow LED 4 minutes cooling and 4 minutes heating for 15 minutes In both Auto mode 1 amp 2 after 15 minute the system will auto lock itself and run for approximately another 5 minutes in safe shutdown mode with decreasing cooling effect It is necessary to let the system run for the last 5 minutes and let it shut down on its own During this 5 minutes span of automatic safe shutdown mode the temperature levels cannot be changed by the user In both Auto and Manual Mode it is necessary to let the system run for complete 20 minutes and let it shut down on its own Do not switch off or reset the system in between Resetting or switching off the system before the complete
10. anty does not cover damages due to external causes including without limitation damage due to accidents neglect misuse or operation beyond capacity parts damaged by improper installation substitution or parts not approved by Dhama Innovations or any other alteration or repair by others that in Dhama Innovations judgment materially or adversely affects the product or part Use of this product is not a guarantee against injury User should consult with his her health care provider immediately if he she experiences any kind of adverse medical reaction following use of this product User should consult with his her health care professional with any questions as to how this product applies to user s specific medical condition If user does not agree to the above conditions please stop using this product For all servicing and repair inquiries please contact CLIMAWARE Customer Service If you are calling from inside the U S call at 305 252 9076 If you are calling from outside the U S call at 91 888 555 0635 Designed amp Manufactured by dhama Qo INNOVATIONS R Powered by ClimaCon Patent US8397518 amp other patents pending 2 01 ie CLIMA R esse WARE Cryothermic Wrist Wrap OTHER OFFERINGS Fee r revere OL a EVE pronto heat CLIMAWARE Rx Cryothermic System How to obtain warranty service To obtain warranty service please contact CLIMAWARE Rx Cryothermic Wris
11. do not drop throw or abuse e Ifthe Touch Controller Battery Unit has any leaking fluids do not touch and dispose off immediately Dispose according to state regulated norms e Keep away from children below 10 years of age
12. g car e Do not leave the Battery control Unit Touch controller Battery Unit under direct sunlight WARNINGS Improper placement or prolonged use of hot cold therapy could result in tissue damage such as frostbite As a precautionary measure the system is auto programmed to cut off on its own after the completion of around 15 minutes of therapy During the course of therapy patients should monitor the skin surrounding the treated region or the digits of the extremities of the treated limb for any burning itching increased swelling or pain If any of these signs are present or any changes in skin appearance occur such as blisters increased redness discoloration or other noticeable skin changes patients are advised to discontinue use and consult a physician CLIMAWARE Rx Cryothermic Wrist Wrap is not sterile do not place directly against open wounds sores rashes infections or stitches WARNING PRECAUTIONS and SAFETY INSTRUCTIONS related to CLIMAWARE Rx Cryothermic Wrist Wrap e CLIMAWARE Rx Cryothermic Wrist Wrap must only be worn according to the instructions contained in this user manual and used for the areas of application places of use listed e Do not use CLIMAWARE Rx Cryothermic Wrist Wrap in combination with other products or therapy system any intention to do so must be discussed beforehand with your physician e Use with caution when at the highest level of heat therapy Keep the temperatu
13. ht 4 2 oz 120 grams Up to 4 hours up to 4 hours in the lowest temperature setting and up to 1 hour in the highest temperature setting Breathable main body with inbuilt foam cushioning System Runtime Once fully charged always remove the Battery Charger from the electrical power socket and disconnect the charging pin from the Touch Controller Battery Unit Note As a safety precaution the product has been programmed such that it doesn t Material work while it is charging HOW TO WEAR THE COMPLETE WRIST WRAP CLIMAWARE Rx Cryothermic WristWrap Battery unit a Step 3 Insert your hand and position the Wrist Wrap at the appropriate position to ensure that the Cooling heating ceramic plate touches the most pain effected area Step 4 Ensure that the Immobilizer bar is placed on the dorsal surface of the hand and aligned at the center a flat surface Insert straps of the main O a ee Step 6 Insert the Touch Controller Battery Unit into the elastic strap on the immobilizer bar as shown also affix the unit with the velcro hook patch placed below The Wrist Wrap looks like this An extensio cable is provided in the kit to detatch the Touch Controller Battery Unit and extend the wire length in between Thus the Wrist Wrap can be used while keeping the Touch Controller Battery Unit in pocket or on the table Step 7 Plug in the male connectors from the Wrist Wrap Main Body into the r
14. itution is strictly prohibited and would render the warranty void No product liability is accepted in the event of improper use e Never charge Touch controller Battery Unit unattended When charging Li Po batteries you should always remain in constant observation to monitor the charging process and react to potential problems that may occur e If at any time you witness the Touch controller Battery Unit starting to balloon or swell up discontinue the charging process immediately Disconnect the battery and observe it in a safe place for approximately 15 minutes and discard the battery after that Continuing to charge the Touch controller Battery Unit that has begun to swell may result in fire Likewise never use a battery if you find it swollen or ballooned upon purchase e Donot overcharge the Touch controller Battery Unit Once fully charged always remove the Battery Charger from the electrical power socket and disconnect the charging pin from the Touch controller Battery Unit Failure to do so may lead to fire which may result in personal injury and property damage e Do not try to forcefully insert the male connector from the charger into the Touch controller Battery Unit DC output point This will damage the control unit permanently e Do not wet Touch controller Battery Unit Operating the same in wet condition may lead to fire which may result in personal injury and property damage e Do not use other manufacturers wraps with the CLIMAWAR
15. ng Pad Using the s Articulating hinge S N N Immobilizer For moist heat therapy wet and thoroughly For side to side movement of the wrist wring the Moist Heating Pad and wrap iton replace the standard immobilizer bar and the wrist before wearing the wrist wrap use this specially designed immobilizer bar with articulating hinge system Note This pad is to be used only while applying heating in the manual mode Do not use it during auto mode or cooling mode Using the Silicon Pad is provided for extra cushioning Using the Silicon Pad A Silicon Pad is provided for extra cushioning when you are not using the wrist wrap for heating cooling but as anormal brace To use the Silicon Pad place it on the ceramic heating cooling surface on the inner side of the Wrist Wrap Main Body while touching the fabric side of the pad to the skin TECHNICAL SPECIFICATIONS cushion onto the designated velcro patch on the Wrist Wrap main body body into the slots provided on the Detachable Immobilizer bar as shown Step 5 Secure all three straps in place with CONNECTING THE TOUCH CONTROLLER BATTERY UNIT TO THE WRIST WRAP PARTS AND ACCESSORIES RET T Palm cushion After connecting the male DC round pin connector from the product into the designated female DC port on the side of the Touch Controller Battery Unit slide the Silicon power button located on the top side of the pad 4 Touch Con
16. o not expose CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit to high temperatures open fire or direct sunlight for long periods this may lead to fire which may result in personal injury and property damage Opening the CLIMAWARE Rx Cryothermic Wrist Wrap Touch controller Battery Unit casing will void the warranty thereby voiding any product liability Contact us Dhama Innovations Pvt Ltd www climawareonline com Plot 311 Road 25 Jubilee Hills Hyderabad INDIA 500033 Call 91 8885550635 Visit www dhamainnovations com Email info dhamainnovations com Please keep these user manual instructions safe as you may want to read it again later If you have any questions please contact your physician INDICATIONS The system is lightweight portable and is powered by the patented ClimaCon technology which allows for instant application of hot cold and contrast therapy between 47 F to 115 F or 8 C to 46 C anytime and anywhere CLIMAWARE Rx Cryothermic Wrist Wrap provides only symptomatic relief and will not cure the medical condition A Caution Federal law restricts the sale of this device by or on the order of a licensed healthcare practitioner Follow the recommendations of your healthcare practitioner regarding the frequency and duration of use The device is intended to be used by or on the order of healthcare professionals in hospitals outpatient clinics athletic training se
17. om decreased skin sensation or inability to feel cold temperatures Heat therapy Thermotherapy should not be used in patients Who are diabetic or are unable to feel hot or cold temperatures Who are hyper or hypo sensitive to heat Who are in acute stages of injury Who suffer from Deep Vein Thrombosis Who suffer from malignant tumors or circulatory problems Who have any kind of metallic implants Who are extremely sensitive and or allergic to heat CLIMAWARE Rx Cryothermic Wrist Wrap should be used only under the supervision of a licensed healthcare practitioner in patients e Who have Raynaud s disease or cold hypersensitivity cold uticaria e Who have hypertension or extreme low blood pressure e Who have diabetes e Who have compromised local circulation or neurologic impairment including paralysis or localized compromise due to multiple surgical procedures in the affected region Who have rheumatoid arthritis in the affected region Who are unable to feel pain because of advanced age diabetes spinal cord injury medication or have skin that is not sensitive to heat cold or temperature changes The contraindications mentioned above are not exhaustive Please do not use hot cold contrast therapy if you are advised against the same by your doctor or if you have a medical condition which does not permit application of such therapy Various applications of the other accessories provided with the wrist wrap Using the Moist Heati
18. ound pin connecter placed on the side of the Touch Controller Battery Unit as shown velcro WATER FEEDING FOR COLD HOT AND CONTRAST THERAPY To allow heat dissipation to take place more effectively it is absolutely necessary to feed water on the top printed surface of the main body Remember to pour water from the specially designed Water Feeder Bottle provided Warning Do not cover the outer printed surface of the product while the productis in use Do not operate the system without pouring the requisite amount of water on the printed surface Itis necessary to add some amount of water continuously on the product s top printed surface in approximately every 5 10 minutes to make sure that the surface is always wet Itis necessary to slightly wet the skin of the applied area before using the product in heating and contrast mode Failure to comply with the above instructions may cause severe tissue damage and possible heat cold burn to the skin Step 1 Fill the Water Feeder Bottle with clean tap water Step 2 Open the nozzle of the bottle by rotating the top portion of the cap anti clockwise in order to pour water on to the wrap Step 3 Pour 1 4th of the bottle of water at a time on the CLIMAWARE Rx Cryothermic Wrist Wrap to make sure the printed fabric surface is dripping wet The water must be poured evenly over the printed surfaces TOUCH CONTROLLER BATTERY UNIT OPERATION INSTRUCTIONS Power ON OFF b
19. re warm and comfortable but not uncomfortably hot against your skin If the CLIMAWARE Rx Cryothermic Wrist Wrap feels uncomfortably hot lower the heat level If this problem persists discontinue the usage e Do not use CLIMAWARE Rx Cryothermic Wrist Wrap on the skin where topical ointments or sprays have been applied Duration and method of application may be further verified by doctor according to your specific condition e Donotapply heat therapy unattended while sleeping e Make sure that the product and product connectors are absolutely dry whenever you use it again after wet cleaning e Never operate the system with damaged cables or connectors or other mechanical damage or if the unit is otherwise not fully operational e CLIMAWARE Rx Cryothermic Wrist Wrap is an electronic wellness device Handle it with care e Do not use CLIMAWARE Rx Cryothermic Wrist Wrap on a sleeping unconscious person e Incase of any adverse side effects immediately discontinue use and consult a physician e Donot disassemble make alterations crush strike puncture or throw the CLIMAWARE Rx Cryothermic Wrist Wrap Failure to comply with this requirement may adversely affect the product performance thereby voiding any product liability e Do not use CLIMAWARE Rx Cryothermic Wrist Wrap while smoking or near flames or ignition e CLIMAWARE Rx Cryothermic Wrist Wrap must be operated only with CLIMAWARE Rx Cr
20. t Wrap System Customer Service from the U S call at 305 252 9076 from outside of the U S call 91 888 555 0635 or write to info dhamainnovations com You must have the original Proof of Purchase issued by Dhama Innovations or its authorized dealer at the time of purchase to qualify for warranty service If you qualify for warranty service from Dhama Innovations you will be issued a Return Authorization Number RAN When you return the CLIMAWARE Rx Cryothermic Wrist Wrap to Dhama Innovations you must write the RAN on the outside of the package Dhama Innovations will not accept returned CLIMAWARE Rx Cryothermic Wrist Wrap without the RAN on the package If you return the CLIMAWARE Rx Cryothermic Wrist Wrap to Dhama Innovations you must assume the risk of damage or loss during shipping You must use the original packaging or the equivalent Dhama Innovations may require you to verify in writing that you are the original purchaser of the CLIMAWARE Rx Cryothermic Wrist Wrap Dhama Innovations may choose to replace or repair the CLIMAWARE Rx Cryothermic Wrist Wrap with either a new or a reconditioned product The returned product shall become Dhama Innovations property upon receipt The replaced CLIMAWARE Rx Cryothermic Wrist Wrap is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period This warranty is not transferrable
21. troller Battery Unit to switch ON the system WristWrap main body Articulating Touch Controller hinge E Ez 1 Battery Unit Immobilizer CHARGING THE BATTERY Immobilizer Battery Charger Water Feeder Bottle Extension Cable Recharge the Touch Controller Battery Unit fully before using the product for the first time Attributes CLIMAWARE Rx Cryothermic Wrist Wrap 47 F to 115 F or 8 C to 46 C Under indoor setting at 24 C Wrist Wrap Weight 4 7 oz 135 grams Battery Type Rechargeable Lithium Polymer Battery 7 4V Charger type US pin type Input 100 240V AC 50 60 Hz Output 4 2V DC 1200 mAh User Controllable Temperature Range Plug in the charger into the wall electrical socket and connect the Charger pin to the Touch Controller Battery Unit Use only the charger provided with the product The Touch Controller Battery Unit can be charged both in switch ON or OFF position Turn on the electric power wall socket switch to start charging the battery A red light on the Battery Charger indicates that charging is in progress In Power ON position the battery level indicating Green LEDs and the Red LED on the charger indicates that charging isin progress In Power OFF position only the Red LED on the charger indicates that charging is in progress When the battery is fully charged the Battery Charger light turns Green Touch Controller Battery Unit weig
22. ttings or home settings CLIMAWARE Rx Cryothermic Wrist Wrap is indicated for Carpal Tunnel syndrome Wrist Sprains and Strains Wrist Fractures Post Cast Healing Kienbock s Disease Overuse injuries Tendonitis Night Splinting e e e e e e e e CONTRAINDICATIONS While using for support and immobilization Assuming that the product is used according to the instructions and given that it is non invasive there are no side effects The product is contraindicated for unstable wrist fractures fixed bony contractures and moderate to severe flexor tone All braces and support if overly tight can cause discomfort due to compression If you observe any change in your general state or deterioration of your condition please consult your doctor During a prolonged period of inactivity it is recommended to reduce the tension on your device until you resume normal activities where you will reset the tension to original level recommended to you Any modifications of the product will result in the annulment of the warranty along with the denial of any responsibilities on our part Contraindications while using hot cold contrast therapy Cold Therapy Cryotherapy should not be used in patients e Who have significant vascular impairment in the affected region e Who have acute paroxysmal cold hemoglobinuria or cryoglobulinemia e Who have open wounds or suffer from infectious skin conditions e Who suffer fr
23. utton Slide the power button located on the top side of the Touch Controller Battery Unit to switch ON the system As soon as the Touch Controller Battery Unit is switched ON the LEDs indicating the battery status will start to glow and cooling level Low in manual mode will be turned ON by default Battery Charging point eee dhama Battery Status As soon as the Touch Controller Battery Unit is RN INNOVATIONS switched ON the Green LEDs indicating the battery status will start to glow The Green LEDs indicating the battery status will stop glowing when the battery runs out and needs to be recharged To recharge follow the instructions given in the section Charging the Battery e 3 glowing LEDs indicate more than 80 battery e 2glowing LEDs indicate less than 80 battery e 1glowing LED indicates less than 15 battery Lock Unlock This is a toggle button Long touch this button once to lock the system All touch controls will be inactive when the system is locked To unlock the system long touch lock unlock button again This is an inbuilt safety feature similar to mobile phones designed to prevent accidental pressing of controls It is always recommended to lock the system after the preferred mode of operation is selected Lock Cold Unlock Heat Toggle means to alternate between options with the operation of a eh are Wrap single button ontroller Battery Unit Temperature level The Touch Controller
24. yothermic Wrist Wrap Battery control Unit Touch controller Battery Unit provided with each product In case of wearing out of the battery the entire unit needs to be replaced which may be purchased directly from the company retail outlet Unauthorized part substitutions may result in fire electric shock or other hazards Failure to comply with this requirement may adversely affect the product performance thereby voiding any product liability CLIMAWARE Rx Cryothermic Wrist Wrap should be kept away from children below 10 years of age e Do not use CLIMAWARE Rx Cryothermic Wrist Wrap for heat moist heat therapy on anyone who cannot operate the product and the Touch controller Battery Unit e Failure to properly follow the set up instructions may result in inadequate therapy e In addition to the precautions listed above additional warnings and safety precautions are posted throughout this manual Read the user manual completely and carefully follow these instructions prior to operating the system Improper usage may possibly cause severe heat cold burn Precautions Do not wash wet the CLIMAWARE Rx Cryothermic Wrist Wrap Battery control Unit Touch controller Battery Unit or the Battery Charger Doing so will void your warranty and any product liability In case it gets wet by accident make sure that you dry it completely before connecting the CLIMAWARE Rx Cryothermic Wrist Wrap to the Battery Unit Do not put CLIMA