VdS Shunt lock function 3066
Contents
1. 12029 Anke Wiedemann 12030 Sophia Voth 12024 Peter M hlbauer Praktikant 12025 Sonja Reimann Produktmanagement 12026 Hannah Stein 12027 Rainer Hobel 12028 Dieter L bcke XX XX X XX X XX X XX X XX X XX X XX X XX x x Engang Geb ude 402 2 06 X X X XXXXXXX XXXXXX XXXXXX B ro 201 x XXXXXX KK KK XX D B ro 202 x XXXXXX XXXXXX E B ro 203 x XXXXXX XXXXXX FA B ro 204 x XXXXXX Bereit m COM1 CD COM2 aus COM3 aus COM4 aus VdS Shunt lock function 3066 Page 21 In the locking plan make a cross by the employees who are authorized to turn the alarm system on and off You do not have to reprogram the transponders in this case Approve your locking system and program the activation unit under Programming gt Locking The activation unit needs supply voltage during the programming You can provide this with a 9 volt compound battery for example Program activation unit s and deactivation units separately from one another Do not wire the two components until after you have programmed them successfully 5 v Mustermann Is SimonsVoss Digitales SchlieBsystem 3060 Datei Bearbeiten Neu Ansicht Genehmigen Programmierung Netzwerk Optionen Zeitzonenpl ne Dg Ee al c 2814 vi m le seje 2 D D 12020 H
2. MA SA and DA Operating voltage 8 to 16 volts DC Current consumption lt 30 mA Applied relay Max continuous current 1 A for switching output Max switch on current 1 A Max switching voltage 40 V AC Max switching capacity 30 W 60 VA Tamper contact Make contact 1 A 30 V DC Transponder range with extended antenna 1 3 cm 4 to 1 2 inches Temperature range 10 C to 55 C 14 F to 131 F Degree of VdS environmental protection class Il Housing Material S B or A B S Color White Dimensions L W H 85 x 85 x 26 mm Article description Article number VdS no G 101 160
3. For emergencies you can use the locking plan software to program a transponder that cancels the deactivation of the locking cylinder so that the doors can be opened with an authorized transponder However the alarm system remains activated externally Page 6 1 2 VdS Shunt lock function 3066 Time zone control und access logging The activation units master and slaves can log activation deactivation switches access logging and you can define time slots during which it is possible to activate deactivate the system time zone control Access logging The activation unit stores the last 128 activations deactivations with date time and the user name of the transponder You can read out the data with the programming device or over the network Time zone control You can program activation units in such a way that authorized transponders can only switch the alarm system at certain times Refer to the Software Operating Instructions Chapter C Safety Remarks gt Read through the assembly instructions carefully and thoroughly before installing and commissioning the Shunt lock components They contain important information on the assembly programming and operation The components are built in accordance with the latest state of the technology Use them only as instructed and when they are in perfect technical condition and are properly installed according to the technical specifications The manufacturer is not liable
4. Page 22 3 2 Programming the Deactivation Units DA Click the line in the locking plan above the one where you want to add a deactivation unit Select New gt Locking Then give the deactivation unit a name 2 Such as Deactivation unit main entrance In the field Type select Control unit Click OK amp Exit If you want to set up additional deactivation units repeat these steps If you always add the deactivation units above the accompanying digital locking cylinder you will have a better overview of the system 5 v Mustermann Is SimonsVoss Digitales SchlieBsystem 3060 migen Programmierung N tk Optionen Olle al e 5 ala lt al seje 4 8 A v B e oo t S HP idjc i 5 G Oo ie 2 8 Sle hee Sic d 2 eg a tli E 5n 5181581658 isle Simons Voss AE iliis Sodiilboillils CIE ts Ble le le l l Sls lx le technologies EE EE EE EE SES ESS le SS Slee S26 SchlieBung SIS IZ IF BIE fle la lala 2 amp SSASSSRSISS Q 9 9 19 19 0 19 19 9 S SchlieBanlage Mustermann z SN ININIE eie NN IN Eentralschlie amp ung TUS T rbezeichnung Deaktivierungseinheit Haupteingang x x x x x x xx xx Schranke Fee XXXXX XXXXX Geb ude 402 1 0G Verwaltung i kein El Eingang Geb ude 402 1 06 8i it XXXXX KKK KX Serverrau
5. 5 2 VdS Shunt lock function 3066 Special Versions of the Shunt lock function 3066 Operating the Activation Unit without a Deactivation Unit If you want to activate and deactivate the burglar alarm system externally with the transponder instead of with a key you only need a master activation unit MA In this case however you will lose the true purpose of the Shunt lock function You need to connect only pins 1 and 2 for the power supply the floating switch contact pins 5 6 7 and the sabotage contacts pins 8 to 11 Do not connect the other lines of the activation unit refer to Chapter 2 3 Operating the Deactivation Unit without an Activation Unit If you continue to operate the alarm system with a standard key you can do without the activation unit Connection assignment Connect the supply voltage separate power supply to soldering terminals 1 and 2 Connect terminals 13 and 15 over a relay contact of the alarm system floating make contact If there is a lock switch contact wire this to soldering terminals 12 and 15 Refer to Chapter 2 2 As long as soldering terminals 13 and 15 are connected to one another for example by a relay point of the alarm system all digital locking cylinders equipped with a deactivation unit are deactivated This means it is not possible to accidentally go through these doors when the alarm system is activated VdS Shunt lock function 3066 Page 29 6 0 Data Sheet
6. it Simons Voss technologies 12018 Hans Joachim Drechsel 12019 Mark Brinkmann 12020 Heinz Bauer Marketing 12012 Karin Attmann 0001 12012 Karin Altmann 12013 Paul Franke Verwaltung 12016 Frank Hinterberger Gesch ftsf hrer 12010 Dr Hans Hubert 12011 Jens Schuster Buchhaltung 12014 Eduard Stein 12015 Friedhelm Schulte 12017 Wolfgang Peters 12031 Winfried Geier 12021 Volker Kunze 12022 Sabine B umler 12023 Anette M ller 12024 Peter M hlbauer 12025 Sonja Reimann Produktmanagement 12026 Hannah Stein 12027 Rainer Hobel 12028 Dieter L bcke 12029 Anke Wiedemann 12030 Sophia Yoth Eentralschlie Bung Haupteingang Deaktivierungseinheit Haupteingang x x x x x x x x x x x x x x x x x Aarmanlage x x X x x x x x X x x X XXXXX XX X Schranke Geb ude 402 1 0G verwaltung Eingang Geb ude 402 1 06 X X XXXX X X X Serverraum B ro 101 B ro 102 B ro 103 B ro 104 B ro 105 B ro 106 Gebaude 402 2 0G Marketing amp Produktmanagement Eingang Geb ude 402 2 0G B ro 201 B ro 202 B ro 203 XX X X XX X X XXXX XXXXXX X XX X IXXXX XXXXXX X XX X mI ustermann Bereit COM CD COM2 aus COM3 aus COM4 aus Page 24 4 0 4 1 VdS Shunt lock function 3066 Installation Installi
7. LED amc cr C te WO 3 O E NO OC CXOOGOCOO OCO c y 3 p 1 8 9 10 NH SABO SABO SABO SABO Soldering terminal assignments Supply voltage positive pole Supply voltage negative pole ground Connection for LED 5 volts in outside area Not used Sabotage contacts Optional lock monitoring contact for activation suppression Deactivation request input Deactivation acknowledgement output Ground identical to soldering terminal 2 Acoustic BAC acknowledgement not for DA Solder terminal for cable screen Jumper settings Jumper B1 can be inserted any way Insert jumper B2 for maximum transmitting range Do not insert jumper B3 Page 9 2 2 1 2 2 2 VdS Shunt lock function 3066 Testing the Deactivation Unit DA To test connect the deactivation unit to a 9 volt compound battery Make sure that the polarity is correct Position the deactivation unit within radio range of the digital locking Deactivation unit gt digital locking cylinder max 40 cm 16 inches Deactivation unit gt digital Smart Relay min 20 cm max 1 m 8 till 40 inches The ranges depend on the structural circumstances and so will vary Make sure that both the deactivation unit and cylinder are correctly programmed refer to Chapter 3 Then connect soldering terminals 13 and 15 ground to one another This deactivates the cylinder Smart Relay signal tone for cylinder and the LED on the deactivation unit goes out Th
8. for damages that are caused by use that does not comply with the directions Keep the documentation that comes with the product and system specific notices in a safe place Only trained experts are authorized to perform installation programming and repair work Soldering and connection work anywhere in the entire system must be performed only when the system is voltage free Soldering work must be performed with a temperature controlled soldering iron that is electrically insulated from the power system Observe VDE safety regulations and regulations from the local electric utility Do not use the components in areas subject to explosion hazards or in areas with fumes that dissolve metal or plastic DIN norms and the guidelines of VdS Class C must be adhered to Page 7 2 0 2 1 VdS Shunt lock function 3066 Assembly Instructions General Information on Installing the Components Always install in the protected area for example in the inside area behind the door behind brickwork etc There are some materials however such as stainless steel or aluminum that can significantly reduce the range There may also be sources of magnetic interference near the activation or deactivation unit that also very strongly reduce the range When making the connections please observe the technical specifications for the activation unit and the relay refer to Chap 6 Failing to comply with these values can lead to interference with
9. the Shunt lock function several times Page 20 3 0 3 1 VdS Shunt lock function 3066 Programming Programming the Activation Units MA and SA If you want to add the shunt lock components at some time after the initial installation open your locking plan with the password If this is the initial installation create a new locking plan Click the locking above which you want to add an activation unit Select New gt Locking Then give the activation unit a name 2 For example Alarm system In the field Type select Control unit Click OK amp Exit or OK amp Next if you want to set up additional activation units slaves s Y Mustermann Is SimonsVoss Digitales SchlieBsystem 3060 Datei Bearbeiten Neu Ansicht Genehmigen Programmierung Netzwerk Optionen Zeitzonenplane 2 Der tS alee El alal v ml e elel 2 3 Schuster n Altmann 0001 n Altmann dhelm Schulte ik Hinterberger fgang Peters s Joachim Drechsel lt Brinkmann fried Geier ter Kunze Simons Voss m technologies Ei SchlieBanlage Mustemann g amp g Eentralschlie amp ung Haupteingang T rbezeichnung Alamantagd Geb ude 402 1 06 Verwaltung Typ Zeitzonenplan Eingang Geb ude 402 1 06 C Einsteckschlo kein El C Steuereinheit SchlieBzylinder Konfiguration C M belschlo OK amp Beenden Beenden Hilfe Geb ude 402 2 0G Marketing amp Produktmanagement Ed abine B umler 12023 Anette M ller
10. the function of the components or even to destruction of the components Make absolutely sure that the polarity is correct You can attach the components deactivation and activation units on the wall surface with two countersunk head screws 3 5 x 30 mm and two S5 plastic plugs not included in the delivery The two enclosed VdS adhesive labels guarantee permanent evidence if the housing is opened without authorization sealing of the cover screws Programming the components Program the Shunt lock components and accompanying lockings before installation When doing this please keep the following points in mind e Program activation units deactivation units and locking cylinders in the same locking plan e Select type Control unit for the shunt lock components e During programming supply only one component with power at a time and do not connect the cables to one another e After programming read out the components and verify that they report correctly Refer to Chapter 3 for more detailed information Installing a locking that should be deactivated with the Shunt lock function Install the digital locking Smart Relay or locking cylinder that should be deactivated by the Shunt lock function Follow the installation guidelines These are under the relevant heading in the system manual Page 8 VdS Shunt lock function 3066 2 2 Installing the Deactivation Unit DA 8 16V Masse 15 LED Rs 5 ex Re L
11. 26 VdS Shunt lock function 3066 4 3 VdS Compliant Installation of the Activation Unit MA and SA VdS compliant installation must guarantee that the system can be activated from the outside but not from the inside This requires the following measures 3 6 Use activation units with antenna extender Shorten the color coded cable on the antenna extender to the required length pull the cable through the bore hole in the aluminum screening sleeve and connect the cable to soldering connections 16 to 20 as follows 16 green 17 blue 18 screening 19 red 20 yellow Insert jumper B2 The range of the antennas is reduced if you use the aluminum sleeve correctly Bore a blind hole 23 mm in the outside wall insert the antenna extender in the blind hole and fix in position See drawing below While doing this make sure that you get within at least 2 cm approximately 3 4 inch of the front side of the antenna extender from the outside and that you guarantee a minimum distance of at least 12 cm 4 3 4 inches to the front side of the antenna extender from the inside This is approximately the thickness of the wall The distance between the antenna and activation unit must be at least 30 cm 12 inches and the distance from the locking cylinder to the antenna must be at least 1 m 40 inches We recommend that you mark the position of the blind hole on the outside wall with a red point or similar marking The person au
12. VdS Shunt lock function 3066 Version December 2003 Simons Voss technologies VdS Shunt lock function 3066 Register Deactivation unit Deactivation unit Deactivation unit p Q4 4 I l l r l l r I i I r l I i i 1 2 aS 2 i L L Activation unit with f configuration a M MASTER TRE Alarm System 1 0 Functional Description 2 0 1 1 1 2 General Information Safety Remarks Assembly Instructions 2 1 2 2 2 2 1 2 2 2 2 2 3 2 3 2 3 1 2 3 2 2 3 3 General Information on Installing the Components Installing the Deactivation Unit DA Testing the Deactivation Unit DA Connecting Power Supply Lock Contact Evaluation and Sabotage Contacts oon N o m HL Connecting Deactivation Request and eactivation Acknowledgement Installing the Master Activation Unit MA Testing the Master Activation Unit MA Connecting Power Supply Switch Contacts and abotage Contacts Connecting Deactivation Request Deactivation Acknowledgement and Activation Request 10 11 12 12 13 Register 3 0 4 0 5 0 6 0 VdS Shunt lock function 3066 2 4 Installing the Slave Activation Unit SA 14 2 4 1 Testing the Slave Activation Unit SA 15 2 4 2 Connecting Power Supply Sabotage Contacts and Local 15 Activation Suppression 15 2 4 3 Connecting Deactivation Acknowledgement and Activation Request 16 2 Wiring the Shunt Lock Compone
13. e cylinder no longer responds to transponders When you remove the connection the cylinder or Smart Relay is activated The LED lights again Repeat the tests several times until the radio link works perfectly You can increase the range between the cylinder and deactivation unit by using FH version locking cylinders with plastic inside knob Once the deactivation unit successfully passes the test you can carry out the actual permanent installation Connecting Power Supply Lock Contact Evaluation and Sabotage Contacts e Power supply Connect the positive pole of a direct current source between 8 16 V recommended 12 V to soldering terminal 1 Note that the voltage is not permitted to exceed a value of 16 V under any circumstances Connect soldering terminal 2 to ground e Optional lock contact evaluation global activation suppression If you want the alarm system to remain inactivated until all doors of the security area are closed meaning the bolts have been driven out you can connect the lock switch contact to soldering terminals 12 and 15 The lock contact must be a floating electric strike If there is no lock contact not VdS compliant it is of course impossible to check whether all doors have been locked which means that it is also possible to activate the alarm system if some doors are not locked In any case however all cylinders must have been successfully deactivated If there is no lock contac
14. einz Bauer Marketing 12027 Rainer Hobel 12028 Dieter L bcke Simons Voss technologies 12018 Hans Joachim Drechsel 12019 Mark Brinkmann 12012 Karin Attmann 0001 12012 Karin Altmann 12013 Paul Franke Verwaltung 12016 Frank Hinterberger 12010 Dr Hans Hubert 12011 Jens Schuster 12017 Wolfgang Peters Buchhaltung 12015 Friedhelm Schulte Gesch ftsf hrer 12014 Eduard Stein 12031 Winfried Geier 12021 Volker Kunze 12022 Sabine B umler 12023 Anette M ller 12024 Peter M hlbauer 12025 Sonja Reimann Produktmanagement 12026 Hannah Stein 12029 Anke Wiedemann 12030 Sophia Yoth ZentralschlieBung Haupteingang x x x x X X x x x X x X x x X X X X X x x x x Alarmanlage j XXXXX XX X XXXX x Schranke Geb ude 402 1 06 Verwaltung Eingang Geb ude 402 1 06 X X X x x x X x XX X Serverraum B ro 101 Baro 102 Biro 103 B ro 104 B ro 105 b ro 106 Geb ude 402 2 0G Marketing amp Produktmanagement Eingang Geb ude 402 2 06 B ro 201 B ro 202 B ro 203 B ro 204 XX X X X X XX X X X XXXXXX X XXX XXXXXX X XxX XXXX X XXXX X X X 4 x x Xx iix xxx XXXXX IXXXXX XXXXX 2 Mustermann Bereit 1 COM1 CD COM2 aus COM3 aus COM4 aus VdS Shunt lock function 3066
15. ernal activation In this case wire the SA separately from other activation units Connect soldering terminals 5 to 7 to the internal activation connection of the BAC Refer to the BAS installer instructions for wiring information e Sabotage contacts Connect them to soldering terminals 8 to 11 Solder the Rs resistor terminating resistor or short circuit to soldering pins X27 and X28 refer to the drawing e Optional local activation suppression If you want to use activation suppression connect a floating contact between soldering terminals 12 and 15 When the contact is closed it is impossible to activate or deactivate the system locally from this SA This has no effect on the activation behavior of other activation units Connecting Deactivation Acknowledgement and Activation Request Refer to Chapter 2 5 Wiring the Shunt Lock Components We recommend that you use the following types of lines J Y ST Y 6 or 8 pin 0 6 mm The diameter should be fit to the length of the line so that the minimum voltage for the components never falls below 8 volt voltage drop on the line ATTENTION You should always shield longer lines Connect the deactivation request deactivation acknowledgement and activation request to one another according to the drawing below Also connect the supply voltage everywhere pins 1 and 2 with the positive on 1 and ground on 2 Make sure that the polarity is correct Then measure the voltage on all unit
16. his corresponds to the strongly reduced range when the screening sleeve is inserted on the antenna extender refer to Chap 4 3 Make sure that all components are correctly programmed refer to Chap 3 Insert jumper B1 on the right Then test whether the relay on the activation unit switches soldering terminals 5 and 7 by operating the transponder two times in quick succession within 0 5 2 sec Then you must convert the acoustic activation acknowledgement to BAC operation insert jumper Bion the left and test it by attempting to activate the system Once the slave activation unit successfully passes the test you can carry out the actual permanent installation Connecting Power Supply Sabotage Contacts and Local Activation Suppression e Power supply Connect the positive pole of a direct current source between 8 16 V recommended 12 V to soldering terminal 1 Note that the voltage is not permitted to exceed a value of 16 V under any circumstances Connect soldering terminal 2 to ground e External light emitting diode You can connect an external light emitting diode to soldering terminals 3 and 4 for visual signaling When the transponder is operated successfully the LED blinks Maximum length of the line 10 m 33 feet Page 16 2 4 3 2 5 VdS Shunt lock function 3066 e Switch contacts Soldering terminal 5 to 7 are not needed for the slave activation unit unless you want to use the SA for int
17. igh impedance until each deactivation unit has successfully deactivated its neighboring cylinder and if there is lock contact evaluation all bolts have An MA draws the deactivation request line pin 14 to ground potential after someone authorized to activate the system operates the transponder This causes each DA to start to deactivate its cylinder If the MA receives a positive deactivation acknowledgement within no more than 10 sec deactivation acknowledgement line goes high impedance a floating contact is closed between pin 5 and pin 7 This requests the BAC to 2 3 4 been pushed forward 5 activate the system 6 When someone authorized to activate the system operates the transponder again the floating contact between pins 5 and 7 is separated immediately so that the BAC is requested to deactivate Then the deactivation request line pin 14 is set to high impedance The DAs then start to reactivate unless the BAC continues to draw the deactivation request line to ground potential in order to prevent the cylinders from reactivating for example until the system deactivation is complete Page 18 7 VdS Shunt lock function 3066 Instead of operating the transponder at the MA the slave activation units after transponder activation at the SA by someone authorized to activate the system can trigger an activation or deactivation process with a high impedance ground potential high impedance pulse on
18. ive a positive acknowledgement until all lockings have been successfully deactivated It then uses a floating contact to activate the alarm system externally compelled signaling The light emitting diodes of the activation units signal this by lighting for 2 5 seconds The light emitting diode s on the deactivation unit s go out The BAS acoustically signals for example on the activation unit that the system has been successfully activated Switching off the alarm system The person with switching authorization again presses his or her transponder twice in quick succession within transmitting range of the activation unit The deactivation units signal this to the digital locking cylinders or the digital Smart Relays The LEDs on the activation units visually signal that the system has been successfully deactivated by blinking 1x short long The LEDs on the deactivation unit s light again The LEDs on the deactivation units are used only for testing purposes so they do not have to be brought out where they can be seen Now it is possible to access the doors again with all authorized transponders By simply clicking the transponder button within transmitting range of activation units you can determine the activation state of the alarm system if the LEDs on the activation units are brought out where they can be seen 1 x short long blinking means deactivated 1 x long 2 5 sec blinking means activated Activation transponder
19. m C SchlieBzylinder Konfiguration Biro 101 C M belschlo B ro 102 B ro 103 B ro 104 OK amp Weiter OK amp Beenden Beenden Hilfe B ro 105 B ro 106 xx KKK KK KK Geb ude 402 2 06 Marketing amp Produktmanagement RO PE cae Pape PURES io Engang Geb ude 402 2 06 XX X X XXXXXXX XXXXXX XXX D buro 201 XX XXXXXX XX I B ro 202 XX XXXXXX XX IS Biro 203 xx XXXXXX XX EJ B ro 204 XX XX 4 Bereit l COM1 CD COM2 aus COM3 aus COM4 aus Deactivation units do not need any authorizations which means that you do not have to insert any crosses Approve your locking system and program the deactivation units under Programming gt Locking The deactivation unit needs supply voltage during the programming You can provide this with a 9 volt compound battery for example Program activation unit s and deactivation units separately from one another Do not wire the two components until after you have programmed them successfully VdS Shunt lock function 3066 Page 23 Read out the shunt lock components Programming gt Read unknown locking The type of the component deactivation unit or activation unit is displayed Attention The display treats slave activation units as normal Smart Relays s v Mustermann Is SimonsVoss Digitales SchlieBsystem 3060 Datei Bearbeiten Neu Ansicht Genehmigen Programmierung Netzwerk Optionen Zeitzonenpl ne Diasa e l ele c 14 v mi 1 o zee
20. mpound battery Make sure that the polarity is correct Do not wire the other contacts for this test Transponder gt master activation unit 1 cm to max 3 cm 4 to 1 2 inches This corresponds to the strongly reduced range when the screening sleeve is inserted on the antenna extender refer to Chap 4 3 Make sure that all components are correctly programmed refer to Chap 3 Insert jumper B1 on the right Then test whether the relay on the activation unit switches soldering terminals 5 and 7 by operating the transponder two times in quick succession within 0 5 2 sec An acoustic signal indicates the switching state of the alarm system A 2 5 second long continuous tone signals that the activation contact was closed and a two part signal tone short long means that the activation contact is open again de activated Then you must convert the acoustic activation acknowledgement to BAC operation insert jumper B1 to the left and test it by attempting to activate the system Once the master activation unit has successfully passed the test you can carry out the actual permanent installation Connecting Power Supply Switch Contacts and Sabotage Contacts e Power supply Connect the positive pole of a direct current source between 8 16 V recommended 12 V to soldering terminal 1 Note that the voltage is not permitted to exceed a value of 16 V under any circumstances Connect soldering terminal 2 to gro
21. ng the Deactivation Unit Install the deactivation unit DA in the immediate vicinity of the digital locking cylinder no farther than approximately 30 cm or 12 inches This guarantees optimum transmission traffic Align the deactivation unit so that both fastening screws lie in a horizontal line Then the antennas point directly to the locking cylinder refer to the drawing below You can always achieve better ranges if you use FH cylinders plastic knob instead of stainless steel Page 25 4 2 VdS Shunt lock function 3066 Installing the Activation Unit MA and SA You should install the activation unit AU no matter whether it is a master activation unit MA or slave activation unit SA above the door case and above the locking cylinder In any case the distance to other SimonsVoss components must be at least 1 m or approximately 40 inches refer to the drawing Only in this way can you rule out mutual interference influences If you install it above the door case align the activation unit so that the two fastening screws lie in a horizontal line This eliminates interference when the door is used in the normal way Refer to the drawing below This installation is done without the antenna extender and with jumper B2 is inserted max range Because this simple installation method allows the system t AU Min 100 cm 40 inches Max 30 cm 12 inches DA m LT zr cylinder Page
22. nts 16 2 6 Functional Principles 17 Programming 20 3 1 Programming the Activation Units MA and SA 20 3 2 Programming the Deactivation Units DA 22 Installation 24 4 1 Installing the Deactivation Unit 24 4 2 Installing the Activation Unit MA and SA 25 43 VdS Compliant Installation of the Activation Unit MA and SA 26 Special Versions of the Shunt lock function 3066 28 5 1 Operating the Activation Unit Without a Deactivation Unit 28 5 2 Operating the Deactivation Unit wthout an Activation Unit 28 Data Sheet 29 Page 4 1 0 1 1 VdS Shunt lock function 3066 Functional Description General Information In objects protected by the alarm measures must be taken to prevent any unintentional entry of the secured area when the alarm system burglar alarm system BAS is activated externally because this would trigger a false alarm The Shunt Lock function 3066 implements such a feature without requiring extensive work on the door or doorframe The following components are needed for this 1 Activation unit s MA and SA Such a unit is used to switch the alarm system You need at least one activation unit AU to activate and deactivate the system externally If you want to be able to activate deactivate from several locations you need the corresponding number of activation units You can use a mouse click to issue the authorizations for activating and deactivating the alarm system in the locking plan Basically
23. otage contacts Activation request from slave activation units SAs optional Deactivation acknowledgement input Activation suppression when ground is applied Deactivation request output Ground identical to soldering terminal 2 Acoustic activation acknowledgement by BAC not for DA Solder terminal for cable screen Jumper settings Jumper connects right and middle contacts of B1 Acoustic acknowledgement after activation release by activation unit Jumper connects left and middle contacts of B1 Acoustic acknowledgement after final activation is done by the BAC this is the VdS compliant configuration Page 12 2 3 1 2 3 2 VdS Shunt lock function 3066 The BAC must draw pin 29 to ground for the acoustic acknowledgement Jumper B2 is inserted Maximum transmitting range For VdS compliant installation however you must then work with external keys to differentiate between outside and inside refer to 4 3 VdS Compliant Installation of the Activation Unit n VdS compliant installation the range of the antenna extender is reduced solely by the correct use of the aluminum sleeve Refer to 4 3 VdS Compliant Installation of the Activation Unit Install the activation unit so that the distance between its antenna and other digital components is at least 1 m 40 inches Testing the Master Activation Unit MA Before final installation apply voltage to contacts 1 and 2 of the activation unit co
24. s and make sure that the voltage never falls below a value of 8v and never exceeds 16V Deactivation Activation request Deactivation request Page 17 2 6 VdS Shunt lock function 3066 DA MA SA Deactivation request Solder pin 13 Solder pin 14 Deactivation acknowledgement Solder pin 14 Solder pin 13 Solder pin 13 Activation request Solder pin 12 Solder pin 14 Activation suppression Solder pin 12 Solder pin 12 Supply voltage positive Solder pin 1 Solder pin 1 Solder pin 1 Supply voltage ground Solder pin 2 Solder pin 2 Solder pin 2 DA Deactivation unit MA SA Master activation unit Slave activation unit Functional Principles 1 A DA deactivates a neighboring cylinder if the deactivation request line pin 13 is drawn to ground potential by the MA or the BAC A DA reactivates a neighboring cylinder as soon as the deactivation request line pin 13 is high impedance which means that the MA output pin 14 and the corresponding BAC output must both be high impedance A DA draws the deactivation acknowledgement line pin 14 to ground as long as its neighboring cylinder is activated or as long as the lock monitoring input pin 12 is connected to ground Therefore a lock contact must be an electric strike between ground and pin 12 that opens when the bolt is pushed forward Consequently the deactivation acknowledgement line does not go to h
25. t simply do not connect soldering terminals 12 and 15 Page 10 2 2 3 VdS Shunt lock function 3066 Test the shunt lock function again after you have connected the lock switch contact Try to deactivate the locking cylinder or Smart Relay even when the bolts have not been driven out e External light emitting diode You can connect an external light emitting diode to soldering terminals 3 and 4 so that you have a visual display in the outside area showing whether the cylinder or Smart Relay is activated or deactivated Maximum length of the line 10 m 33 feet e Switch contacts not used Soldering terminals 5 to 7 are not needed for the deactivation unit e Sabotage contacts Connect these to soldering terminals 8 to 11 Solder the Rs resistor terminating resistor or short circuit to soldering pins X27 and X28 refer to the drawing Install other deactivation units if any according to the same plan Connecting Deactivation Request and Deactivation Acknowledgement Refer to Chapter 2 5 Page 11 VdS Shunt lock function 3066 2 3 Installing the Master Activation Unit MA 8 16V Viasse LED LED SABO SABO SABO SABO Soldering terminal assignments 1 2 3 4 5 7 8 11 12 13 14 15 29 30 Supply voltage positive pole Supply voltage negative pole ground Connection for LED 5 volts in outside area Floating contacts for switching the alarm system Sab
26. the activation request line pin 14 Connecting plan example with one MA and 2 DAs BAC MA EC 000 rt 12 5 ch DolQoqogoooooo DA1 DA2 COOP cem o9 Rs jae 699 eo em ae 14 On TER 000600000000 CO00000000000 VdS Shunt lock function 3066 Page 19 After you have completed the installation work carry out a function test Do this by operating an authorized transponder near the activation unit twice in quick succession The light emitting diodes on the activation unit and the deactivation unit s go out and you receive the acoustic acknowledgement signal from the BAC or if jumper B1 is inserted on the right the signal lasting 2 5 seconds from the activation unit indicating that the alarm system has been activated Check whether the cylinder s or Smart Relay s have been deactivated Operate the transponder near the activation unit two times again This unit signals the activation of the lockings only visually on the LED with 1 x short long blinking or if jumper B1 is inserted on the right with a double signal tone from the activation unit The LEDs on the shunt lock components light again The locking cylinder or Smart Relay is now active and can be switched if you operate an authorized transponder one time Please set the acoustic activation acknowledgement to BAC operation insert jumper B1 on the left if you have not done this yet Test
27. there is a difference between the master activation unit MA and the slave activation units SA The SAs are needed only if you want to activate or deactivate from more than one location It is always the MA that activates or deactivates the alarm system externally using a floating contact SAs only send the appropriate requests to the MA You can also activate internally by using SAs that are separately connected to the internal activation connection of the burglar alarm center BAC 2 Deactivation units DA These are installed next to the doors of the secured area and in the immediate vicinity of the digital cylinder They see to it that these doors cannot be accidentally opened even with an authorized transponder if the alarm system has been activated externally This reliably prevents false alarms EMA ES at ns SE als SSM VdS Shunt lock function 3066 Page 5 Switching on the alarm system burglar alarm system BAS The person with switching authorization presses his or her transponder near an activation unit two times in quick succession within 2 sec This sends a signal to all deactivation units present If lock contacts are connected to the deactivation units the DAs first verifies that the doors have been correctly locked The digital locking cylinders or Smart Relays are not deactivated unless this is the case so that it is no longer possible to enter the secured area The activation unit does not rece
28. thorized to activate the system must hold the transponder at this point in order to be able to communicate with the antenna extender Outside wall Inside wall Antenna extender Activation unit Install the deactivation unit according to the description in Chapter 4 1 VdS Shunt lock function 3066 Page 27 7 You can also optionally use an activation unit without antenna extender Install it as described in Chapter 4 2 In order to guarantee that the system can be externally activated from the outside only you must then install a button in the outside area You cannot externally activate or deactivate the system by operating a transponder until this button is pushed The deactivation acknowledgement input pin 13 is suppressed on master activation units MAs as long as it is connected to ground normally closed button in outside area A Schottky diode decouples the deactivation acknowledgement line see below This diode is needed however only if there are slave activation units With slave activation units SAs you can apply the activation suppression pin 12 to ground over a normally closed button that is in the outside area If there is also an activation suppression button on the master you should use a circuit according to the figure below Deactivation Activation request Deactivation request Electric strike in outside Electric strike in area outside area Page 28 5 0 5 1
29. und Page 13 2 3 3 VdS Shunt lock function 3066 e External light emitting diode You can connect an external light emitting diode to soldering terminals 3 and 4 for visual signaling When the transponder is operated successfully the LED blinks Maximum length of the line 10 m 33 feet e Switch contacts Connect them to the alarm system Soldering terminal 5 is the common contact 6 is for the electric strike and 7 for the make contact Refer to the BAS installer instructions for the wiring and values for the terminating resistor s Rx wire jumper Ry wire jumper Rz terminating resistor e Sabotage contacts Connect them to soldering terminals 8 to 11 Solder the Rs resistor terminating resistor or short circuit to soldering pins X27 and X28 refer to the drawing e Global activation suppression optional Applies ground such as pin 15 or pin 2 to pin 13 over a floating contact so that the system cannot be activated Connecting Deactivation Request Deactivation Acknowledgement and Activation Request Refer to Chapter 2 5 VdS Shunt lock function 3066 Page 14 2 4 installing the Slave Activation Unit SA 8 16V Masse LED LED SABO SABO SABO SABO Soldering terminal assignments 1 Supply voltage positive pole 2 Supply voltage negative pole ground 3 4 Connection for LED 5 volts in outside area 5 7 Notused 8 11 Sabotage contacts 12 Optional activation s
30. uppression when ground is applied for example lock contact evaluation 13 Deactivation acknowledgement input 14 Activation request to the master activation unit MA output 15 Ground identical to soldering terminal 2 29 Acoustic activation acknowledgement by BAC not for DA 30 Solder terminal for cable screen Jumper settings Jumper connects right and middle contacts of B1 Acoustic acknowledgement after activation release by activation unit Jumper connects left and middle contacts of B1 Acoustic acknowledgement after final activation is done by the BAC The BAC must draw pin 29 to ground VdS compliant configuration Page 15 2 4 1 2 4 2 VdS Shunt lock function 3066 Jumper B2 is inserted Maximum transmitting range For VdS compliant installation however you must then work with external keys to differentiate between outside and inside Refer to 4 3 VdS Compliant Installation of the Activation Unit n VdS compliant installation the range of the antenna extender is reduced solely by the correct use of the aluminum sleeve Refer to 4 3 VdS Compliant Installation of the Activation Unit Testing the Slave Activation Unit SA Before final installation apply voltage to contacts 1 and 2 of the activation unit compound battery Make sure that the polarity is correct Do not wire the other contacts for this test Transponder gt slave activation unit 1 cm to max 3 cm 4 to 1 2 inches T
Download Pdf Manuals
Related Search
Related Contents
BF-630X/BF-830X Consulter la fiche technique 「国内受入研修」報告書 (PDF:6.1M) - 石炭資源情報 Vzug 85A330 Manual de instrucciones Modelo: WS-2301 Samsung SGH-E710 Manual de Usuario Manual - Ventisol - Ventilador de Parede 1 Metro.cdr Owners Manual - All Pro Sound Confiture d`0ranges Création: TEFAL FR404615 Instruction Manual Copyright © All rights reserved.