Home

1.User`s Guide For THR8 Remote Controller

image

Contents

1. 1 User s Guide For THR8 Remote Controller 1 1 Features Remote ON OFF inverter operation Ignition lockout information display and Return Override Function Acting 1 2 Specification Input Voltage Range 10 5 60 Vdc depends on Inverter model Operating Temperature Range 0 40 C Storage Temperature Range 30 70 C Stand By Current Draw lt 40mA Applicable Models THPS 1000 2000 3000 series 1 3 Introduction O Inverter Status Solid Red Inverting Blinking Fast R O F Acting Blinking Slow Ignition INVERTER REMOTE O e This is a simple ON OFF remote control K K K Function or Ignition Lockout Function K K TO INVERTER 2 C INTERNAL AUX 12V Steady red LED light in dicates the Inverter is ON Fast flashing red LED light indicates that it is in Return Override Function selection status Slow flashing red LED light indicates that it is in Ignition Lockout Function selection status e The wire JP1 is placed inside the remote controller and it is to indicate either Return Override JP1 jumper Open Return Override Function JP1 jumper Short Ignition Lockout Function Please note that the default mode is OPEN e The wire must go with a 12 Volt 0 5A fuse with proper sizes e Connect the wire RJ 11 to the remote port in front of the panel K K e Installation Procedure 1 Refer to the dr
2. awing see Figure 1 for screw hole and cutout dimensions 2 Use the cable between THR8 remote and the inverter 3 Switch the inverter to REMO position Ignition Lockout function The Ignition lockout function is to turn the Inverter OFF when the auxiliary input wiring is connected to the ACC accessory and 12 Volts is applied Return Override Function The Return Override Function is to turn the Inverter ON when the auxiliary input wiring is connected to the reverse gear Shift and 12 Volts is applied For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686 4281 AO Z e 4 gi eoo Lize A Inverter Status Solid Red Inverting Blinking Fast R O F Acting aS es Blinking Slow Ignition Lockout a OU CU CO O U A CM Nemes A N INVERTER REMOTE AUU L20 c0 y Figure 1 1 4 Drawings of THR8 Remote Control Cables rCONDUCTOR icin INSULATION LJ ACKET CABLE STRU CT URE A A WARNING DO NOT use standard telephone cable THOR Manufacturing Inc 7050 W Palmetto Park Rd Suite 15 Boca Raton FL 33433 Phone 1 866 955 THOR 8467 www THORpowerproducts com

Download Pdf Manuals

image

Related Search

Related Contents

  Gefen EXT-DVI-841 video switch  

Copyright © All rights reserved.
Failed to retrieve file