Agilent 82357B
Contents
1. 118 9276201 For other unlisted Countries www agilent com find contactus Revised October 14 2010 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2011 Printed in USA May 6 2011 5989 1889EN oh Agilent Technologies
2. This article is the third of a series of four application notes with System Developers in mind It explains with great depth how you can simplify test integration by taking advantage of open connectivity standards Meet your throughput requirements yet stay within budget Where to download www agilent com System Developer Guide Using USB in the Test and Measurement Environment Application note 1465 12 5989 1417EN This article is the fourth of a series of four application notes with System Developers in mind It explains with great depth how you can simplify test integration by taking advantage of open connectivity standards Meet your throughput requirements yet stay within budget Where to download www agilent com ia Agilent Email Updates www agilent com find emailupdates Get the latest information on the products and applications you select AXie www axiestandard org AdvancedTCA Extensions for Instrumentation and Test AXle is an open standard that extends the AdvancedTCA for general purpose and semiconductor test Agilent is a founding member of the AXle consortium LXI www lxistandard org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems Agilent is a founding member of the LXI consortium 1 2008 Quality Management System www agilent com quality rat http www pxisa org PCI eXtensions for Instrumentation PXI modular instrumentation d
3. LED indicators READY ACCESS FAIL Maximum instrument 14 instruments daisy chain via GPIB A maximum of connection 4 converters can be connected to the PC Configuration Plug and play Warranty 1 year EMC and safety Dimensions Length width and height e IEC 61010 1 2001 EN 61010 1 2001 USA UL61010 1 2004 Canada CSA C22 2 No 61010 1 2004 105 mm L x 64 mm W x 30 mm H including connectors Weight 215 grams Environmental specifications Operating environment 0 C to 55 C Operating humidity Up to 90 at 40 C non condensing Storage environment 40 C to 70 C Storage humidity Ordering information Includes Up to 90 at 65 C non condensing Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM Accessories None Agilent 82350B High Performance PCI GPIB Interface Card Features e PCI IEEE 488 interface for PCs Transfer rates up to 900 KB s Dual processor support on the latest Windows operating system Best for e Maximum GPIB throughput for all configurations High performance for manufacturing test applications The 82350B is Agilent s highest performance GPIB interface With a direct PCI computer connection transaction overhead is minimized for the best overall performance The 82350B card de couples GPIB transfers from PCI bus transfers Buffering provides connectivity and system performance
4. as 1 2 3 Install Agilent 10 Libraries Suite software on your PC Establish a connection in less than 15 minutes Agilent I0 Libraries Suite eliminates the many working hours it takes to connect and configure PC controlled test systems especially if it involves instruments from multiple vendors In fact with 10 Libraries connecting your instruments to a PC is as easy as connecting a PC to a printer Easily mix instruments from different vendors Agilent I0 Libraries Suite eliminates headaches associated with trying to combine hardware and software from different vendors The software is compatible with GPIB USB LAN and RS 232 test instruments that adhere to the supported interface standards no matter who makes them When you install the 10 Libraries Suite the software checks for the presence of other 1 0 software on your computer If it finds another ven dor s VISA libraries it automatically installs in a side by side mode that allows you to use the existing 1 0 software and the Agilent software together in multi vendor systems Work in the environment that s comfortable to you In addition the 10 Libraries are compatible with a variety of applica tion development environments and programming APIs including Agilent or NI VISA VISA COM SICL Agilent 488 compatible with NI 488 2 and Agilent VEE There is flexibility to choose the software and hardware of your choice to get your job done Works with
5. easy to connect and disconnect without having to shut down the computer No external power supplies are necessary The 82357B USB GPIB interface implements USB 1 1 12 Mbits s and is compatible with USB 2 0 The 82357B USB GPIB interface uses a thin flexible high quality USB cable that is USB 2 0 compliant The USB cable is shielded and the connector is specified to 1 500 insertions ensur ing a durable connection and reliable data transfer CN Boosting performance with simplest connectivity ye sj F 82357B technical specifications General requirements Minimum system requirements Refer to page 4 for requirements in using the Agilent 10 Libraries software included with the connectivity product Supported standards Supports USB 2 0 high speed and full speed e Standard USB endpoints supported IEEE 488 1 and IEEE 488 2 compatible e SICL and VISA 2 2 Unsupported GPIB modes of operation General characteristics Power Maximum data rate GPIB e Pass Control e Non System Controller mode USB bus powered device 5 V 500 mA maximum 200 mA typical 1 15 MB s Connectors Standard 24 pin IEEE 488 Standard USB A USB hubs Self powered hubs Parallel polling Cable A single parallel poll can easily check up to eight individual devices at once corresponding to the number of data lines on the GPIB 2 5 meters shielded connector rated for 1 500 insertions
6. that is superior to direct memory access DMA The hardware is software configurable and compatible with the plug and play standard for easy hardware installation The GPIB interface card plugs into a 5 volt PCI slot in the backplane of your PC This traditional GPIB connection still offers the highest throughput 82350B technical specifications General requirements Minimum system requirements Refer to page 4 for requirements in using the Agilent 10 Libraries software included with the connectivity product PCI bus slot 5 V PCI slot 32 bits Supported standards General characteristics Power IEEE 488 1 and IEEE 488 2 compatible PCI rev 2 1 Backplane 5 V PCI Connectors Standard 24 pin GPIB IEEE 488 e 5V PCI Maximum data rate 900 KB s Maximum instrument 14 instruments daisy chain via GPIB connection Buffering Built in Configuration Plug and play EMC and safety IEC 61326 1 Group 1 Class A IEC 61010 1 Warranty 1 year Dimensions Length width and height 122 mm L x 122 mm W x 22 mm H a full height PCI card Weight 0 091 kg Environmental specifications Operating environment 0 C to 55 C Operating humidity Storage environment Up to 90 at 40 C non condensing 40 C to 70 C Storage humidity Ordering information Includes Up to 90 at 65 C non condensing Agilent 10 Libraries Suite and VISA SICL progr
7. 0833D GPIB cable 0 5 meter 10833A GPIB cable 1 meter 10833B GPIB cable 2m 10833C GPIB cable 4m 10833F GPIB cable 6m 10833G GPIB cable 8m Adapters The 10834A GPIB to GPIB adapter can help when limited rear panel space and other design consider ations make cabling difficult The 10834A adapter extends the first cable by 2 3 cm away from the rear panel to provide clearance for other connectors switches and cables Type GPIB board Product 82350B PCI GPIB card Best for GPIB connection for PCl based PCs or workstations Maximum throughput for all configurations up to 900 KB s 82351A PCle GPIB card GPIB connection for PCle based PCs or workstations High throughput applications up to 1 4 MB s USB converter 82357B USB GPIB card GPIB connectivity even for notebook computers e Easiest GPIB instrument set up to PC LAN converter E5810A LAN GPIB gateway Connection to remote GPIB and RS 232 instruments Test system sharing and collaboration among multiple users Cable 10833x GPIB cables Connection between GPIB instruments daisy chain Connection from GPIB instrument to the PCI GPIB or PCle GPIB card Connection from GPIB instrument to the LAN GPIB gateway Adapter 10834A GPIB to GPIB adapter 2 3 cm clearance at GPIB instrument s rear panel Typical configurations of PC to instrument connection LAN RS 232 Bi Direct or via Network E5810A LAN GPI
8. Agilent Connectivity Hardware for PC to Instrument Connections Data Sheet GET Nak with Agilent GPIB Instrument Control Products os Agilent Technologies Introducing Agilent GPIB Instrument Control Products Agilent connectivity products enable e Easy connection to GPIB instruments based on simple plug and play setup and configuration e Use of PC standard interfaces that are prevalent even on notebook PCs such as USB and LAN e A wide selection of interfaces to fit your test system application PCI PCle USB and LAN e Use of industry standard 1 0 libraries which makes integration of existing instruments and software programs in a single system easy even if you use multiple instrument vendors Table of Contents Connecting is AS easy as 1 2 3 x sccsvassciisceisossecsecescssicesansasassastasinssecissises 3 Agilent 10 Libraries Suite 16 0 oo cccceeeseeeesesesesseseeseeseeteeeseeeeees 4 Agilent 82357B USB GPIB Interface Converter cccceeeee 5 Agilent 82350B High Performance PCI GPIB Interface Card 6 Agilent 82351A High Performance PCI Express PCle GPIB Interface Gard sssrini aaaeaii 7 Agilent E5810A LAN GPIB Gateway ccsscssesesesseesesseeeeseeseees 8 Agilent GPIB Instrument Control Products Summary 0 9 Related Agilent Literature oo ccscssssesesescsesessesesesesssseeeeseeeeseaees 10 Contact 6 21 a oe eee ne a rN Te Back cover Connecting is as Easy
9. B or 82350BPCI GPiB 82351A PCle GPIB H instrument i instrument l 823578 USB GPIB 1A aR c Related Agilent Literature Publication title Pub number Simplified PC Connections for GPIB Instruments Application note 1409 1 5988 5897EN This article covers the common PC to GPIB instrument configurations It explains the 1 0 hardware and software considerations for easy GPIB instrument hook up and automation Where to download www agilent com Modern Connectivity Using USB and LAN Connectivity Converters Application note 1475 1 5989 0123EN As more and more instruments are equipped with PC standard interfaces such as USB and LAN various instrument control converters are available in the market today besides the traditional PCI GPIB cards What are the advantages of one over the other What are the key factors that you need to consider before you decide on buying the instrument control product that s most suitable for your application This article explains all of the above with a detailed comparison of data rates over various interfaces Where to download www agilent com Computer Connectivity Considerations Application note 1465 2 5988 9818EN This article complements the above 5989 0123EN with additional focus on instrument to PC configuration and cost comparison Where to download www agilent com Tips and Tricks for Using USB LAN and GPIB 5989 3312EN This article provides a variety of t
10. amming manuals on CD ROM Accessories GPIB cables adapter see page 9 Agilent 82351A High Performance PCI Express PCle GPIB Interface Card Features Compact half height size 68 9 mm e High transfer rate of 1 4 MB s e High flexibility via up plugging to x4 or x8 PCle slots 3 3 V signal level for lower power consumption Best for e Bandwidth intensive PC applications e Adding GPIB connection for PCle based PCs or workstations High transfer rate for demanding test applications The Agilent 82351A PCle GPIB interface card is designed for integration into next generation PCs or workstations It offers fast data transmission for various demanding test applications that require data to be transferred to memory fast enough without any loss or overwriting PCle PCI Express is an evolutionary version of PCI that offers a higher transfer rate across a low number of wires It is also backward compatible with PCI software so you don t need to perform any code re configuration The powerful bus architecture of PCle allows bidirectional data transmis sion and the implementation of a new class of test applications New standard for high speed internal devices 82351A technical specifications General requirements Minimum system requirements Refer to page 4 for requirements in using the Agilent 10 Libraries software included with the connectivity product PCI bus slot Supported
11. elivers a rugged PC based high performance measurement and automation system Agilent Channel Partners wwwagilent com find channelpartners Get the best of both worlds Agilent s measurement expertise and product breadth combined with channel partner convenience PCle and PCI Express are US registered trademarks and or service marks of PCI SIG Windows Windows Vista and Microsoft are trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries www agilent com www agilent com find gpib For more information on Agilent Technologies products applications or services please contact your local Agilent office The complete list is available at www agilent com find contactus Americas Canada 877 894 4414 Brazil 11 4197 3500 Mexico 01800 5064 800 United States 800 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 421 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries 65 375 8100 Europe amp Middle East Belgium 32 0 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 0 10 855 2100 France 0825 010 700 0 125 minute Germany 49 0 7031 464 6333 Ireland 1890 924 204 Israel 972 3 9288 504 544 Italy 39 02 92 60 8484 Netherlands 31 0 20 547 2111 Spain 34 91 631 3300 Sweden 0200 88 22 55 United Kingdom 44 0
12. figure nec essary network parameters including its IP address The gateway can be controlled from multiple locations and by multiple users via your LAN so it is easy to share control of instru ments from locations worldwide For easy remote access enter the IP address from the digital display as the URL in your web browser and gain access to connected GPIB and RS 232 instruments Then use your browser to send instrument com mands interactively and quickly see your measurement results Use the digital display and LEDs to check the IP address and troubleshoot locally System use For system environments the E5810A gateway can be mounted on a rack The rack mount kit Option 100 allows two devices to be placed side by side in one rack width With its built in power supply there are no additional power modules to mount Take advantage of LAN technology for your GPIB instruments and test systems YE Aepieet Techenlagies ESSI0OA E5810A technical specifications General requirements Minimum system requirements Refer to page 4 for requirements in using the Agilent 10 Libraries software included with the connectivity product Supported standards General characteristics Input voltage IEEE 488 1 and IEEE 488 2 compatible 10BASE T 100BASE TX networks VXI 11 protocol e RS 232 e VISA 2 2 and Agilent SICL Universal input 100 to 240 V 10 47 to 63 Hz Power 25 VA peak 7 5 Watts
13. ically scans and configures your instrument I0 helps you get connected quickly and easily and displays the status of your interfaces and instruments Interactive 10 Lets you quickly send commands to instruments and read responses 10 Monitor Lets you monitor and debug 1 0 calls made on any of Agilent s supported buses using Agilent SICL VISA VISA COM or Agilent IVI instrument drivers released after September 18 2010 10 control Provides easy access to the IO Libraries Suite from the Windows system tray viFind32 Debug utility uses VISA functions to find resources and lists them in a console window See the following URL for more information or for the latest updates www agilent com find iosuite Agilent 82357B USB GPIB Interface Converter Features e Fast and easy connection to GPIB instruments e Uses standard USB and IEEE 488 interfaces e Maximum GPIB transfer rate of 1 15 MB s e Parallel polling capability Best for e Easiest GPIB connectivity e Notebook computer GPIB connection Connect GPIB instruments quickly and easily to your computer s USB port The Agilent 82357B USB GPIB interface provides a direct connection from the USB port on your desktop and laptop computers to GPIB instru ments Once the software is loaded your computer automatically detects the 82357B when it is connected to the USB port of the computer The 82357B is a plug and play device It is also hot pluggable making it
14. ips and tricks that will help you create flexible test systems that can easily incorporate USB LAN GPIB and RS 232C Where to download www agilent com Tips on using Agilent GPIB Solutions in National Instrument s LabVIEW Environment 5990 3731EN This article provides answers to frequently asked questions about incorporating Agilent GPIB connectivity products into a National Instrument s LabVIEW system Easy to follow steps are also documented in a video Where to download www agilent com find gpibtips System Developer Guide Using LAN in Test Systems The Basics Application note 1465 9 5989 1412EN This article is the first of a series of four application notes with System Developers in mind It explains with great depth how you can simplify test integration by taking advantage of open connectivity standards Meet your throughput requirements yet stay within budget Where to download www agilent com System Developer Guide Using LAN in Test Systems Network Configuration Application note 1465 10 5989 1413EN This article is the second of a series of four application notes with System Developers in mind It explains with great depth how you can simplify test integration by taking advantage of open connectivity standards Meet your throughput requirements yet stay within budget Where to download www agilent com System Developer Guide Using LAN in Test Systems PC Configuration Application note 1465 11 5989 1415EN
15. millions of existing instruments from hundreds of vendors Agilent connectivity products and 10 Libraries are trusted and known for their reliability The 10 Libraries ships with more than 150 instruments from Agilent Technologies If you already own an Agilent connectivity product or instrument you can download the latest version of Agilent I0 Libraries Suite for free Agilent I0 Libraries Suite 16 0 System requirements PC software Operating system PC hardware Processor e Windows 7 32 bit and 64 bit Starter Home Basic Home Premium Professional Ultimate Enterprise e Windows Vista SP1 and SP2 32 bit and 64 bit Home Home Premium Business Ultimate Enterprise Editions Windows XP Pro or Home edition service pack 3 or later 32 bit only 600 MHz class 800 MHz or greater recommended RAM Windows XP 256 MB minimum 7 GB or greater recommended Windows Vista or Windows 7 1 GB minimum Hard disk space required 1 5 GB Display 800 x 600 256 colors Supported development environments and supported 1 0 software VB6 VISA COM VISA SICL Agilent 488 Excel VBA C C Managed C VISA COM VISA Agilent 488 NET languages VB NET C VISA COM VISA Agilent 488 LabVIEW VISA Agilent 488 MATLAB VISA Note Agilent I0 Libraries Suite supports VEE Pro program development with drivers and or Direct 10 1 0 utilities Connection Expert Automat
16. standards General characteristics Power 3 3 V PCle slot 32 bits e PCle rev 1 0a IEEE 488 1 and IEEE 488 2 compatible Backplane 3 3 V PCle Connectors Standard 24 pin IEEE 488 1 5 V PCle Maximum data rate 1 4 MB s Maximum instrument 14 instruments daisy chain via GPIB connection Buffering Built in Configuration Plug and play EMC and safety e IEC 61010 1 2001 EN61010 1 2001 e IEC 61326 2002 EN61326 1997 A1 1998 A2 2001 A3 2003 e Pollution Degree 2 Indoor use only Warranty Dimensions Width depth and height 1 year 120 8 mm W x 158 0 mm D x 21 6 mm H Weight 0 082 kg Environmental specifications Operating environment 5 C to 60 C Operating humidity Storage environment Up to 90 at 40 C non condensing 40 C to 70 C Storage humidity Ordering information Includes Up to 90 at 65 C non condensing Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM Accessories GPIB cables adapter see page 9 Agilent E5810A LAN GPIB Gateway Features e Remote access and control of GPIB instruments via LAN e Easy setup and use via digital display and web browser Best for e Connection to remote GPIB and RS 232 instrumentation e Shared test systems Remote access and collaboration with GPIB instruments via your LAN The E5810A can use DHCP if avail able to automatically con
17. typical Power line frequency 47 to 63 Hz Connectors Std 24 pin GPIB IEEE 488 RS 232 9 pin LAN RJ 45 Maximum data rates 900 KB s GPIB port 115 Kb s RS 232 port Maximum instrument 14 instruments daisy chain via GPIB connection 1 RS 232 device Up to 16 simultaneous connectivity connections Indicators LEDs for Power Activity Fault EMC and safety e IEC 61326 1 Group 1 Class A e IEC 61010 1 Pollution Degree 2 Indoor use only Warranty 1 year Network protocols Dimensions Width depth and height See the E5810A User s Manual for supported network protocols and functions 212 3 W x 230 D x 43 4 H mm 1U height rack Weight 1 6 kg Environmental specifications Operating environment 5 C to 60 C Operating humidity Up to 95 at 40 C non condensing Storage environment Storage humidity Ordering information Includes 40 C to 70 C Up to 90 at 65 C non condensing Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM Accessories GPIB cables adapter see page 9 e Rack Mount Kit Option 100 Agilent GPIB Instrument Control Products Summary Cables Agilent also offers a variety of cables that provide easy and reliable connec tions Agilent cables are engineered for exceptional reliability and durability even under the harshest conditions Cable Length 1
Download Pdf Manuals
Related Search
Related Contents
Manuel du produit Samsung SGH-E210 User Manual Oricom CARE80 User's Manual LEVANCIO取扱説明書-多機能電話機(IX-24KT-N)編 manuale - Cablotecnica Avaya 4620/4620SW/4621SW/4622SW/4625SW User's Manual Bedienungsanleitung - GMC User Manual - Hope Industrial Systems descargar - John Deere IMPRESSA F50 / F5 / F505 Short operating instructions Copyright © All rights reserved.