Fire Control Panel FCP dc3400 SC

image

Contents

1. ccccccccsscccsssecssseeecseesesseeeesseresesseeeeseeeesaees 9 4 1 3 Message Structure c ccscccssssssssssssssssssssesseessesssnesseesseessenesseesseessnesseesseesaes 10 ED DIS Pla one entend t 10 AOA Meaning ON MC LEDS sonen toernee a ami Daana R 10 Operating States sccctssisseets eastitadsceecdisncnticadsceintinucatntadsesintacueasntedeeianteds 11 alea a 11 TT ALERTE EEEN 12 Del Aarm MAIN AAE eene enen nenten an ma nee ntt 12 5 2 2 Alarm delay amp detector zone dependency eneen 12 5 2 3 Alarm Maintenance Mode nanne nenneereenseerenneerenesenrenserrenens 13 FoU neee 13 Maintenance Servic nnen venne eernsenrnserrnsenenserensevenserennereenserennserenseernserenvens 14 SAT DISADIEMEND aaasta aaa aaa 14 5 4 2 Maintenance mode nnee eeneeneenseerenseerennserrenneerenereneenverrenens 14 Operation procedures at event sss uunannsnennansenrnnnseernnenns 15 AEM MAAIEN aaasta N 15 eee 15 FAUS eenden dadde eee dede badeend reddende 16 Operation and Setting u sanasssurnannserrnenserrnnnnsenrnensserrnenns 17 Operating authorisation access Levels nn nnuersnereeneneersnensnenenerrnnn 17 Functions in the In operation WindOW nnen enne erennserrenseereneerenneerrenseens 18 Lod sSllenc amp AlafmMS Saitama k lamata hasta Mantas aaa ae 18 7 2 2 Disabling the Transmission Unit nnen ennen ennenreneereneersneereneens 18 122229 18 1244 lt Delay ONION aema tetten 18 Ve U
2. The dc3400 SC system includes several compatible assemblies as well as small individual central applications Currently the FCP dc3400 SC monitors a loop wiring system which may include up to 126 loop devices which in turn can be split into 126 detector zones with a loop length of up to 3000 m The loop wiring system is a monitored 2 wire bus with a ring topology The system guarantees a safe detection of fire due to the individual identification of the detectors and or the addressed and control components and provokes a predefined action The different LEDs on the panel indicate current alarms faults and other messages The display which can be easily operated and understood provides comprehensible clear text information with regards to the operation of faults and alarms 4 Operation of the dc3400 SC The FCP dc3400 SC is housed in a sheet steel casing The panel is protected with a key against unauthorized access The following operating and display elements can be accessed from the outside e Display e LED display 4 1 Display The FCP dc3400 SC is equipped with a touch screen display in a landscape format which can be used to control the program sequence with only a single touch You can operate the display with your fingers or by using a PDA pen Warning Never use a ball point pen or other objects with a sharp tip Using such objects will lead to damage of the display Clean the display with a soft dry cloth Do not use
3. Job Fire Control Panel Fe FCP dc3400 SC Operation Manual ZON JOD NZ detectomat Operation Manual FCP dc3400 SC detectomat GmbH Headquarter Phone 49 0 4102 2114 60 An der Strusbek 5 Fax 49 0 4102 2114 670 D 22926 Ahrensburg Hotline Phone See www detectomat com Fax 49 0 4102 2114 9670 Manual No 56244 Version 2 1 19 07 2011 Please specify your customer number when contacting the hotline Index 1 1 1 2 1 3 2 1 2 2 2 3 3 1 4 1 4 2 5 1 5 2 5 3 5 4 6 1 6 2 6 3 7 1 7 2 7 3 7 4 Operation Manual FCP dc3400 SC Operation manual purpose and structure naan aao oon nnenerrnnnn 5 Purpose of this manual naaar enneneeeneerrenseereneerennserrenseerenseerennsereenveerens 5 Structure ofthe ANNA snorrende edentate ede 5 Further DOCUMENTATION nnn anseer eneen eenserrenseereneerennserrenseerentersennserrenvervens 5 General safety notes unanassurrnannenrnnnsenrnnnneerrnennenrnnnnnenrnnnnsenn 6 Intended APPIIGAUON 2 lavale aaea aatal aaa aasal aaa 6 Requirements for the operating company nennen enneeneeneee renner eneen ensen eenverrens 6 Datel InStallAONS t nna E T E ka iii uti i 7 Product INTOFMAUION igaaastane 8 Brief CSCI a a AA AA A AA RAD SATA METSA PA 8 Operation of the dc3400 SC naan annanennnneennennenennennenrnennsen 8 DISDIAV reren eneen 8 41 1 Normal Operation MOOE annae ensen ennereneersnversnsersnserenvens 9 4 1 2 Function Keys and Main M nu
4. from detector entry field and enter the detector number as of which detector in the zone needs to be disabled 5 Touch the to detector entry field and enter the detector number up to which detectors in the zone are to be disabled 6 Press the Ok button On the display a disable message appears specifying which detectors have been disabled The disablement counter located in the top centre of the display will show the amount of disablements Also the Disable LED will be on 1 4 2 Disabling zones In the disable zone screen you can choose which zone s you wish to disable 1 Starting from the In operation screen press Menu Disable Zone You will then see the following in the display 2 Touch the Sub Panel entry field and enter the number of the required sub panel via the keypad 3 Touch the from Zone entry field and enter the zone number you wish to disable 4 Touch the to Zone entry field and enter the zone number up to which zones is to be disabled 5 Press the Ok button On the display a disablement message appears specifying the disabled zones The disablement counter on the display shows the amount of disablements The Disabled LED is also on 7 4 3 Disabling input Not available at present 7 4 4 Disabling outputs Here you can select which outputs on the corresponding modules are to be disabled e Base module 1 Starting from the In operation s
5. SC 1 2 Structure of the manual The following conventions will be applied in this user manual e Lists provided with bullet points only contain information and no working steps e Numbered lists contain a sequence of working steps or hierarchically arranged information e Texts displayed in quotation marks indicate menu options e Shortcuts are displayed in squared brackets e g Reset Important safety precautions and special information are indicated in the text of the manual by pictograms These pictograms have to be followed accord ably Attention Danger of an electric shock Turn the power off before working on electrical connections Severe injuries could be incurred by the user Attention The user is alerted to practices and circumstances that could result in equipment damage or economic loss Note The user obtains additional information that is critical for successful application and understanding of the product 1 3 Further Documentation The present user manual describes all operating procedures which are required for the intended use of the FCP dc3400 SC Further information with regards to the installation commissioning configuration maintenance and service of the product can be found in the Installation Manual FCP dc3400 SC Item No 56245 Version 2 1 5 ZOON JOO Nee detectomat Operation Manual FCP dc3400 SC 2 General safety notes The FC
6. benzene paint thinners or cleaning alcohol spirit If the device has been enabled but has not been used for a period of 12 seconds the background lighting of the display will be disabled automatically normal operation mode The background lighting of the display will be automatically activated if a message alarm fault is detected or if you touch the display Version 2 1 8 Alarms Faults Disable Into Menu ments 0000 0000 0000 0000 30 07 2009 14 08 27 In operation Please touch display for operation Silence oon Mute Delay Reset alarms on off buzzer on off Please select System parameters Set date and time Lamp test Select language Alarm counter Disable Detector 1 Zone 2 from Detector 5 F Sub Panel to Detector Operation Manual FCP dc3400 SC 4 1 1 Normal Operation Mode If the dc3400 SC is in its normal operation mode i e no messages have been received and no functions have been setup from the main menu the menu button will be in the top right of the display The display and keys have the following meaning Display Alarms 0000 Faults 0000 Disablements 0000 Info 0000 Menu Silence alarms Transm Unit Alarm on off Mute buzzer Delay on off Reset Meaning Displays the number of any present alarms Displays the number of any current faults Displays the number of current disablements Displays the number of current information messages M
7. fire is recognised e optical signals Beacons All loop beacons will be disabled by selecting all or Beacons Note The external alarm signals can only be activated by an alarm if they are enabled 1 Starting from the In operation screen press Menu Disable External alarm signals 2 Please select if you want to disable all signals or only the audible or only the visual In the following example all has been selected Press the Ok button The information Disable external alarm signals all appears 3 Press the Ok button in order to disable all external alarm signals The Ext sounders and the disablements LED is on 7 4 6 Disabling Transmission unit alarm Not available at present 7 4 7 Disabling Transmission unit fault Not available at present 7 4 8 Disabling the Fire case control Not available at present 7 4 9 Disabling Output fire protection Not available at present 7 4 10 Disabling the Extinguish command Not available at present Version 2 1 21 detectomat Service Maintenance mode Printer on off Print event log Service Event log vents 21 07 2009 08 12 17 0055 Silenced Audible signals 21 07 2009 08 12 11 0056 Alarm 29501 D10 21 07 2009 08 12 04 Maintenance mode Enable zones for maintenance Disable zones from maintenance Enable detectors for maintenance Disable detectors from maintenance Enabl
8. for operation should only be forwarded to authorised personnel This operation manual does not include general or regional regulations Information about general and regional regulations and rules are prereguisite for the operations of the FCP dc3400 SC Version 2 1 6 Operation Manual FCP dc3400 SC 2 3 Safety Installations Warning Removing or decommissioning safety installations may result in material damage or bodily injuries Thus only authorised service technicians are allowed to remedy any deficiencies with regard to safety installations The functionality of the safety installations has to be checked on a regular basis The FCP dc3400 SC is equipped with different safety installations Monitored emergency power supply Mounting of the batteries Short and open circuit tolerant loop card outputs Powered by a switch mode power supply Fuse protected outputs of the power board card Monitoring of the external signaller output Earthing of all metal parts of the housing Version 2 1 7 ZOON JOO ed detectomat Operation Manual FCP dc3400 SC 3 Product Information 3 1 Brief Description The fire alarm system is the central element with regards to the fire protection of a building This product is used to save lives and to protect people s health the environment as well as material assets It consists of the central fire alarm system the fire detectors as well as the control and alarm organisation
9. intermittent Fault LED intermittent Ext signals LED intermittent Buzzer intermittent Fault LED System LED Buzzer Fault LED System LED Buzzer Version 2 1 Communication with the loop device is causing problems Another detector type than the one configured in the FCP dc3400 has been used A new detector has been integrated to the corresponding loop which has not been configured yet Power supply or control panel defective Mains fault Open circuit between the batteries Short circuit Batteries Low batteries voltage Earth fault within the fire alarm system Open circuit on L Open circuit on L Short circuit on the loop Open circuit in the wiring of the ext signals or missing or wrong EOL resistor fitted Short circuit in the wiring of the ext signals or wrong EOL resistor Storage error Card System fault 25 Operation Manual FCP dc3400 SC Check loop device wiring change loop device if necessary Use the correct detector type or change the configuration Configure the new detector accordingly Check the Input status LED on the power board card Check the mains fuse Check the mains supply Check the input voltage at the power board card Try to reboot the system Check the mains fuse Check the mains connection Check the input voltage at the power board card Check the battery connection Check the fuse on the power board card Check the battery conne
10. 0 SC is in alarm main alarm the following processes are automatically started e The internal buzzer sounds continually e The following LEDs are illuminated Alarm double LED is on Main alarm LED is on Call Fire Brigade alarm LED is on e The display shows the alarm message with any programmed text e According to the dc3400 SC configuration alarm outputs control modules and relays are activated Recommendation for the operating seguence 1 Press the Mute buzzer key The internal buzzer is disabled 2 In the case of an alarm follow your evacuation procedures alerting the fire brigade and inspecting of the activated location of the scene of fire 3 Tosilence any ext sounders press the silence alarms button 4 If the cause of the alarm has been rectified press the Reset button and all modules and detectors will be reset to their normal working state If the ext sounders have been disabled they will have to be enabled again via the Enable menu If the sounders have been silenced using the Silence alarms button then after the reset the sounders are enabled automatically 6 2 Alarms If the dc3400 SC goes into alarm and is set to a detector or zone dependency the following processes are started automatically e The internal buzzer sounds continually e The alarm messages are shown in the display e The following alarms are possible Alarm caused via a detector dependency Fire D1 knock
11. 3 03 12 2010 12 08 59 0001 Detector 1st knock Alarms 0001 Alarm Z 000209 Main Alarm Fire Brigade Called O Battery O O intenari ORO ORO 0 Batey ed Ext Outputs Transm Unit Alarm E a ments 0000 0000 0000 06 12 2010 06 12 2010 09 56 56 0006 Alm maintenance Alarms Faults Disable Info Menu ments 0000 0002 0000 0000 08 28 11 Open circuit L alarms on off on off Operation Manual FCP dc3400 SC Display e On the display information regarding the source the alarm and any programmed message texts are displayed e In the centre of the display where you can scroll using the 4 and keys the first message is displayed In the bottom field you are always shown the last message e The alarm display is zone related The alarm counter only counts the zones that are in alarm If more detectors from one zone are in alarm the number of further detectors are shown in the display on the right between the 4 and keys e g two more detectors In order to view these additional detectors of that zone touch this key 5 2 3 Alarm Maintenance Mode The FCP dc3400 SC is in Maintenance Mode and will not activate the sounders Triggered detectors will be indicated in the Mainten notes window Maintenance is activated directly at the FCP dc3400 SC The alarm status will remain for about 40 seconds LED display e Maintenance mode LED glows yellow when enabled Display e Ifa main
12. E SO En 18 lo EE 19 ISADE a eee 19 7 4 1 Disabling Get CtOIS ccccccssssscsessscsssssssesssseueussusesssenessneusuesusessneneseneueueaees 20 LA DISADINNG ZONCS REE a 20 TAS Disabling MDW eee ere ae oe tnt ert on ee eek 20 TAA DISABIING OHUS imaam 20 7 4 5 Disabling external alarm signals ccccccsscsssscsssecsssesesseeesseeesseeeeseeeesaeeeses 21 Version 2 1 3 ZOON JOO Na detectamat 1 5 7 6 1 1 7 8 7 9 7 10 8 1 9 1 9 2 9 3 9 4 Operation Manual FCP dc3400 SC 7 4 6 Disabling Transmission unit Alarm aaan nennenennenenerenneersneernnenn 21 7 4 7 Disabling Transmission unit fault anneer enneereneeennenn 21 7 4 8 Disabling the Fire case control anne enenennenennenenneersneernnenn 21 7 4 9 Disabling Output fire protection anneer neerenseneenn 21 7 4 10 Disabling the Extinguish command nnen ennen ennenesneereneernnenn 21 Me MA 22 7 5 1 Viewing the service event log nne vanverssverenenvonenvonerensenn 22 7 5 2 Maintenance Mod nn nnnnernnen ennen ennen ennenenneerenerrnneeesneersnenn 22 IC LE 21 lt MAI a aaa aa 22 Setting the time and Aate ccccecccssccssessseccseecseeseseecseeeseeseseseseeeseeseseseeeeseesseeseeeesatens 23 Kiul lkseeee E EE 23 Language SONS nensaha a aa n re kaa aaa 23 Alarm COUNTER wisvsicesencrusiccinevatedesadicndbeavedusiaseivecswssidedivseisusgnvtniediaveinectsatatetincsisestscbiddaeatian 23 Faults and diagnostics displA
13. M double LED red Is illuminated in case of a fire alarm The corresponding alarm is stored and the internal buzzer is activated ed an Disabled FAULT double LED yellow Flashes when a fault is present The fault message is stored and Main Alarm the buzzer is activated Batter O System ee la Ext Outputs A Key Box Open Dis Extinguishing Syst yellow Not available for the dc3400 SC Maintenance Mode Delay ON Earth Fault Transm Unit Alarm Dis Extinguish Syst Operation green Is on when the panel is in normal operation mode Flashes while in service mode O Mans ed Mains yellow Is on when the mains voltage is no longer present and the system is running on batteries Battery yellow Is on when no batteries are present system yellow Is on during a system fault Ext Outputs yellow Is on if the external sounders are disabled Flashes in the case of an external sounder fault Maintenance Mode yellow Is on when the system or zones have been switched to maintenance mode Earth Fault yellow Is on to indicate an earth fault on the system or loop Disabled yellow Is on if detectors zones and modules have been disabled Main Alarm red Is on when a main alarm has been triggered Fire Brigade Called red Not available for the dc3400 SC Call Fire Brigade red The user should alert the fire brigade Key Box Sabotage yellow Not available for the dc3400 SC Key Box Open green Not available for the dc3400 SC Delay ON yellow Is on whe
14. P dc3400 SC meets the present day safety regulations at the time of publication Nevertheless danger could occur by incorrect operation or from misuse of the equipment efor life and limb of the user or a third party e for the FCP dc3400 SC and other material assets of the operator for the efficient usage of the FCP dc3400 SC 2 1 Intended application The FCP dc3400 SC is part of a fire detection system which consists of multiple exchangeable and compatible components from small single panel systems up to large multiple networked detection systems It is exclusively designed to receive analyse and forward measured date received by detection units for example smoke detectors or manual call points For specified normal operation it is also important to e attend and follow the safety instructions in this manual e attend and follow the maintenance instructions in this manual The detectomat GmbH is not liable for defects which occur due to incorrect usage of the fire control panel dc3400 SC 2 2 Requirements for the operating company Installation maintenance and service of the fire control panel may only be carried out by companies which are trained and gualified in the fire alarm industry Operator control actions at an already installed FCP dc3400 SC may only be done by authorised and trained staff taking into account your countries safety regulations For safety reasons and to avoid malicious operations The necessary passwords
15. ain menu key Silence or enable any sounder outputs Turns the transmission unit on or off Mutes or un Mutes the internal buzzer during alarms of faults Enables or disables any delays programmed Resets any faults or fire that may be displayed If the cause has not been solved then the fault or fire message will be indicated again In the present version not available 4 1 2 Function Keys and Main Menu The keys and the menu headings on the display have the following meaning Display Ok lt a Transm Unit Alarm on off Mute buzzer Delay on off fat Enable Disable Service System parameters Set date and time Lamp test select language Alarm counter Keys 0 9 Meaning Scroll up Scroll down Confirm and select Back to previous menu Switches the transmission unit on or off Mutes or un mutes the internal buzzer during alarms of faults Enables or disables any delays programmed Return to the Home screen Enables detectors zones outputs ext sounders which have been disabled Disables detectors zones outputs ext sounders For viewing the event log and to enable disable the maintenance mode To delete the event log read CAN devices and detectors reset to default settings and to view the software version of the panel Set date and time Tests all LEDs touch screen and internal buzzer To change the language Displays the number of main alarms any alarms generated while in maintenance mod
16. al FCP dc3400 SC 7 2 Functions in the In operation window The following functions can be executed in the In operation window e Silence alarms e Transm Unit Alarm on off e Mute buzzer e Delay on off e Reset 7 2 1 Silence alarms Using the Silence alarms button only the audible alarm signals are silenced It has to be noted that they are re activated when another fire alarm from another zone it triggered Silence alarms Confirm with Cancel with Note The external sounders can only be activated if they are enabled Transm Unit Mute Delay oan 1 Inthe In operation screen press Silence alarms button Alarms Faults Disable a ll fer ments The information Silenced sounder appears 21 07 2009 2 Confirm using the Ok button The Ext sounders LED and the disablements LED will 21 07 2009 11 29 04 be on 0001 Silenced Sounder Note Te When the panel is reset the sounders are no longer silenced Alarm 29501 D10 Silence Iranem ma Mute Delay Reset alarms on off buzzer on off 1 2 2 Disabling the Transmission Unit Not available at present 1 2 3 Mute buzzer The internal buzzer will be disabled A new alarm message from a further zone or a new fault message will reactivate the buzzer again 7 2 4 Delay on off The delay function will be activated by pressing this button The delay times can be programmed in the dct progr
17. amming tool Further information can be found in the Installation manual Order No 56245 7 2 5 Reset Resets any fault or fire message if indicated in the display Note If the cause has not been solved then the fault or fire message will be indicated again Version 2 1 18 External alarm signals Transmission unit alarm Transmission unit fault Fire case control Output fire protection Extinguish command Transm Unit Mute Delay Aam Operation Manual FCP dc3400 SC 7 3 Enable Via the level 2 password you can access the Enable menu Disabled elements can be enabled again Disabled messages shown in the display and the LEDS are reset The dc3400 SC offers the following enabling options e Detector zones and or single detectors e Inputs and outputs e External alarm signals e Transmission units alarm amp fault e Fire case controls e Output fire protection e Extinguish command Not available at present The enabling procedure is done in the same way as disabling Instead of selecting the menu Disable you have to select the menu Enable Starting from the In operation menu select the menu sequence Menu Enable All additional steps are similar as described in the next chapter 7 4 Disable Via the password level 2 you can access the Disablement menu The FCP dc3400 SC offers the following disablement options e Detector zones and or single detectors e Inp
18. creen press Menu Disable Output 2 Touch a or in order to select the Basic module option 3 Touch the Sub Panel entry field and enter the number of the desired panel via the keypad 4 Touch the Address entry field and enter the CAN address of the module on which the output is located 5 Touch the from Output entry field and enter the output number which requires disabling 6 Touch the to Output entry field and enter the output number up to which outputs are to be disabled 7 Press the Ok button In the display a disabled message appears specifying which output has been disabled Version 2 1 20 Disable External alarm signals Please select Transm Unit Mute Delay en Disable External alarm signals all Disable External alarm signals all Confirm with Ok Cancel with 5 Transm Unit Mute Delay an Operation Manual FCP dc3400 SC 7 4 5 Disabling external alarm signals All outputs configured as External alarm signals will react to the Disable external alarm signals command e all All external acoustical and optical sounders beacons will be disabled e Acoustical signals Sounders All loop sounders loop sounder modules like AOM OMS and the Ext sounders output on the CP MB basic module The acoustic sounders can also be temporally disabled when the Silence alarms button is pressed The silenced alarm will be re activated if a new alarm
19. ction Check the batteries and exchange them if necessary May occur during a longer mains failure afterwards the batteries have to be recharged Check the batteries and exchange them if necessary Check the system for earth faults and rectify Check the loop wiring Check the loop wiring Check the loop wiring Check wiring of the external signals and or check the EOL resistor Check wiring of the ext signals and or check the EOL resistor Perform a cold start of the fire alarm system exchange the card if necessary Check the signal LEDs Perform a cold start of the fire alarm system exchange the main CPU if problem persists necessary ZOON JOO Nee detectomat Operation Manual FCP dc3400 SC 9 Maintenance Warning Danger due to electric shock Maintenance and repair works at the FCP dc 3400 may only be carried out in a dead voltage state For this purpose the mains supply at the mains adapter connection technology or the mains fuse is to be removed and the emergency power supply batteries are to be disconnected The inspections and maintenance works completed at the FCP dc3400 SC are to be recorded in a logbook 9 1 Inspections 9 1 1 Inspection Periods In order to ensure the operating ability of the FCP dc3400 SC inspections are to be carried out in regular intervals Every day Check the readiness of operation of the FCP dc3400 SC In case of failures that have
20. e identical at both batteries 3 Subsequently enable the mains voltage again Version 2 1 26 Operation Manual FCP dc3400 SC 9 1 3 Charging Voltage Check the batteries charging voltage regularly Aa O N Disable the mains voltage Remove the lines from the battery terminals Enable the mains voltage again The FCP dc3400 SC is running without batteries Measure the voltage at the battery terminals With an environmental temperature of 22 C you must measure 27 3 V there Disable the mains voltage once again and afterwards reconnect the batteries to the power board card Enable the mains voltage again 9 2 Cleaning To clean the outer housing of the FCP dc3400 SC use a moist soft and lint free cloth Do not use Cleaning solvent paint thinners or cleaning agents that contain alcohol spirit If necessary the inside of the housing may and should only be cleaned by the service technician Clean the display with a soft dry cloth Do not use cleaning solvent paint thinners cleaning agents that contain alcohol 9 3 Software Updates The software can be updated and installed with our Updater Tool ut3400 Further information can be found in the Installation manual Ord No 56077 9 4 Environmentally friendly disposal The FCP dc3400 SC contains batteries Exchange these batteries according to the manufacturer s specifications The batteries should only be exchanged by authorised service technicians The ba
21. e or detector zone dependencies are not recorded here numeric keys deletes a wrong entry deletes the whole entry in area 2 Panel required information Entry fields Touch the respective box in order to make an entry In the present version not available Version 2 1 ZOON JOO eau detectomat Operation Manual FCP dc3400 SC 4 1 3 Message Structure The messages in the display are shown as clear text The graphic to the left provides an overview of the general message structure If you scroll using the and x buttons the display automatically resets to the first message after 5 seconds Alarms aults Disable Into Menu menla 0004 0000 0000 0007 03 12 2010 07 54 27 1 Current date and time 03 12 2010 07 53 44 2 Message date and time 0009 Alarm 3 Message number and text Z 0001 D3 PL 3200 0 a 4 Location zone detector number and detector type 5 Custom text for detectors and or detector zones Alarms 0004 A Alarm Z OOD DS 6 Message text fine text 7 Display of the last pending message on off Ee 8 in case of alarm Indicates further detectors in the zone are in alarm in the case of a fault and or a disablement The display remains empty 4 2 LED Display The LED display automatically indicates an alarm fault or any other information generated from the panel 4 2 1 Meaning of the LEDs The LEDs have the following meaning detect control dc3400 Designation display Meaning ALAR
22. e system outputs for maintenanc Disable system outputs from maintena Operation Manual FCP dc3400 SC 7 5 Service Via the level 2 password you can access the Service menu Important information like for example the event log can be viewed 1 Starting from the In operation screen press Menu Service 2 Press the Ok button The password prompt appears 3 Enter the password 4 Press the Ok button The Service menu opens 5 Select one of the following options e Event log e Maintenance mode e Printer on off e Print event log For dc3400 SC no printer is available 7 5 1 Viewing the service event log In the Service Event log menu you can view all activities that have occurred like alarms and faults 1 Starting from the In operation screen select the menu sequence Menu Service Event Log You are in the Service Event log menu On the display the current events appear The buttons have the following functions Display Meaning a Scroll up v Scroll down lt Back to previous menu ut Back to the Home menu 7 5 2 Maintenance Mode In order to test and carry out maintenance work on the fire alarm system without disabling all outputs this mode should be enabled Single zones several zones or even the whole system can be enabled to maintenance mode This function is only for authorised service engineers For further information please refer t
23. have to be enabled again via the Enable menu If the sounders have been silenced using the Silence alarms button then the sounders will be enabled again after pressing Reset 6 3 Faults The following processes are started automatically if a fault is detected by the FCP dc3400 SC e The internal buzzer sounds intermittently e The Fault LED is flashing yellow e On the display the fault message is displayed e Depending on the panel configuration alarm outputs control modules and relays can be activated Warning If a system fault is displayed the function of the dc3400 SC may be impaired You must contact your local service or maintenance company Recommendations for the operating sequence 1 Press the Mute buzzer key The internal buzzer will silence 2 Examine the displayed fault and or the reasons for the fault If possible rectify the fault 3 If it is not possible to rectify the fault note the fault message in the display and inform your local service company 4 Press the Reset button if the fault has been rectified Version 2 1 16 Operation Manual FCP dc3400 SC 7 Operation and Setting When the FCP dc3400 SC is in its normal In operation mode the main menu key is located in the top right hand corner of the display By pressing this menu you are able to access the sub menus which you can see in the picture located to the left 1 Select the corresponding sub menu using
24. incurred check whether they are noted in the operating log and whether measures have been taken for removing the failure Every quarter year The FCP dc3400 SC must be inspected and or tested every three months by an authorised service technician for the following Record the implementation in the operating log e Entries in the operating log e Visual inspection of the FCP dc3400 SC and its modules e Check the external voltage supply e Check the batteries as well as their charging voltage e Test at least one detector from each detector zone e Test the readiness for operation of the alarm signallers e Test the LEDs on the DCP lamp test Every year In addition to the quarterly inspections an authorised service technician must individually inspect each module of the fire alarm system including wiring all outputs and or activations Each detector of the fire alarm system must be tested at least once per year Record the implementation in the operating log 9 1 2 Batteries The batteries must be exchanged according to the manufacturer s specifications after four years however at the latest For more information please refer to chapter Installation manual dc3400 SC 1 Disable the mains voltage The FCP dc3400 SC is now running in battery operation 2 After approx one hour measure the voltage at the battery terminals In order to guarantee the functionality of the FCP dc3400 SC the battery voltage should exceed 12 V and b
25. ing from the In operation screen press Menu Lamp Test 2 Press the Ok button e All LEDs should come on e The display will go out and come on again e The internal buzzer sounds during this test 7 9 Language Settings In the language setting you can choose between English and the alternatively installed language Starting from the In operation menu press Menu Select Language Press the Ok button Select your desired language using the x and buttons Aa O N Press the Ok button The Language Setting English or Language Setting xxxxxx menu opens The information text Language Setting English or Language Setting XXXXXX appears 5 Press the Ok button The menu display now appears in your selected language 7 10 Alarm Counter In the Alarm counter menu the total number of all the main alarms since the installation of the FCP dc3400 SC is recorded The alarm counter can only be deleted via dct 3400 Version 2 1 23 ZOON JOO Nr Operation Manual FCP dc3400 SC detectamat 8 Faults and diagnostics displays 1 0000 0 001 Fault 9501 D9501 PL 3300 OT E ne frans Unit El L larms ie ja 1 El In the following chapter you are given an overview of the possible problems that could occur during commissioning and general operation of the FCP dc3400 SC and the possible remedies Note Faults like e g missing detector o
26. n a delay has been activated In the present version not available Version 2 1 10 Operation Manual FCP dc3400 SC 5 Operating States The current operating states are shown via an LED and in the display If an alarm fault or a disablement message is generated at the same time the messages are displayed according to priority 1 Alarm messages 2 Fault messages 3 Disablement messages 4 Information In this case the message with the higher priority is always displayed 5 1 Operation The In operation state is the normal operating mode of the FCP dc3400 SC For this operation the door of the FCP dc3400 SC must be closed detect control dc3400 ments noo 0000 8000 00 p 30 07 2009 14 08 27 Operation In operation Please k iki danii for operaia OBO Call Fire Brigade Key Box Sabotage Ext Outputs Key Box Open TT va Delay Maintenance Mode Delay OM hutTer amat E E Transm Unit Alarm LED display e Operation LED is on Display e In operation Please touch display for operation Version 2 1 11 4 JOO Nena detectomat Disabled Main Alarm Fire Brigade Called Call Fire Brigade KeyBoxOpen 0 Delay ON Transm Unit Alarm Alarms Faults Disable Info Menu ments 0001 0000 0000 0000 03 12 2010 03 12 2010 10 51 48 0001 Alarm Alarms 0001 I Alarm Z 0001 D 24 Silence Transm Unit Mute Delay oan O
27. ntermittent Buzzer intermittent Disable LED on see message text level 2 Fault message zone see message text level 2 Adhere to the alarm organisation Disable general Disablement see message text level 2 Adhere to the alarm organisation Maintenance mode general Maintenance mode LED on Maintenance mode LED on Version 2 1 Corresponding zone or whole system in maintenance mode Loop member communication Wrong device type New loop device address No display Mains fault Open circuit battery Short circuit Battery Low voltage Battery Earth fault Open circuit Loop Open circuit Loop Short circuit Loop Open circuit acoustic Short circuit acoustic CRC error ROM System Fault messages specified Fault LED intermittent Buzzer intermittent Fault LED intermittent Buzzer intermittent Fault LED intermittent Buzzer intermittent No display Fault LED intermittent Mains LED intermittent Buzzer intermittent Fault LED intermittent Battery LED intermittent Buzzer intermittent Fault LED intermittent Battery LED intermittent Buzzer intermittent Fault LED intermittent Battery LED intermittent Buzzer intermittent Fault LED intermittent Buzzer intermittent Fault LED intermittent Buzzer intermittent Fault LED intermittent Buzzer intermittent Fault LED intermittent Buzzer intermittent Fault LED intermittent Ext Outputs LED intermittent Buzzer
28. o the Installation Manual FCP dc3400 SC 7 6 System Parameters This function is only for authorised service engineers For further information please refer to the Installation Manual FCP dc3400 SC Version 2 1 22 Set date and time Select language English Select language English Confirm with Ok Cancel with eS Transm Unit Mute Delay oan Alarm counter Alarm counter 000000011 Transm Unit Mute Delay aan Operation Manual FCP dc3400 SC 1 1 Setting the time and date In the Set date and time menu you have the possibility to change date and time During the initial commissioning of the FCP dc3400 SC you should check the date and time and correct them if necessary The buttons have the following functions Display A V lt gt Meaning Changing values up down Moving the cursor from one digit to the next Ok Entries are stored lt Back to previous menu ut Back to the Home menu Starting from the In operation screen press Menu Set date and time Press the Ok button The Set date and time view opens Adjust time and date Press the Ok button Time and date are stored in the FCP dc3400 SC 7 8 Lamp Test By means of the lamp test you can check whether all LEDs and all pixels from the display are working and whether the internal buzzer of the FCP dc3400 SC functions properly The test takes about two seconds and is reset automatically 1 Start
29. pen circuits etc are automatically reset when the fault has been rectified self resetting and the respective LED goes out Short circuits and system faults are not self resetting and have to be reset manually 8 1 Current date and current time Message date and message time Message number and message text message text level 1 Location zone number detector number detector type Customer text for detectors and or zone Message text message text level 2 Display of the last currently pending message In the case of alarm Fault messages CON OO RR WN a 9 6 7 4 Message level Message text 1 Alarm 1 Fire Z 1 knock trig 1 Fire D 1 knock trig 1 Alarm MCP 1 Fault 1 Fa Techn message 1 Disable 1 Maintenance mode 1 Alarm in maintenance mode The number of further detectors that are in alarm in the displayed zone appears 8 In case of fault and disablement the display remains empty LED display Cause Meaning Inspection troubleshooting Alarms general Alarm LED on Main alarm Main alarm LED on see message text level 2 Call FB LED on Buzzer on Buzzer on First Alarm in a zone dependency see message text level 2 Buzzer on First Alarm in a detector dependency see message text level 2 Alarm LED on Fire in manual call point zone Main alarm LED on see message text level 2 Call FB LED on Buzzer on Faults general Fault LED intermittent Fault Buzzer intermittent Fault LED i
30. pendency or in delay action mode LED display Alarm double LED is flashing at enabled delay action mode Yellow LED Delay ON is on at enabled delay action mode No LED indication except Operation at detector zone dependency The following alarms can occur Detector dependency Fire D1 knock trig Will occur as soon as a detector or MCP from a configured Detector dependency zone goes into alarm The main alarm will become active as soon as another detector or MCP from the same zone becomes active Zone dependency Fire Z1 knock trig Occurs as soon as a detector or MCP from a zone configured as Zone dependency goes into alarm The main alarm is activated as soon as the second defined zone goes into alarm Alarm with the delay active Occurs if a delay has been enabled and the corresponding detectors become active After receiving the alarm the Delay time starts If within the Delay time the Mute buzzer is pressed the Intervention time will start main alarm starts if the Delay time has expired or the delay is disabled If within the Intervention Time the FCP is reset the alarm is cancelled The main alarm will become active once the Intervention Time has expired The Delay time and Intervention time can be programmed with the dc3400 programming tool The total delay time cannot exceed 10 min Version 2 1 12 ments 0001 0000 0000 0001 03 12 2010 12 09 1
31. peration Ext Outputs O Maintenance Mode Earth Fault Main Alarm Fire Brigade Called Key Box Sabotage 5 O Call Fire Brigade O O Key Box Opan Delay ON oO Transm Unit Alarm Operation Manual FCP dc3400 SC 5 2 Alarms 5 2 1 Alarm Main Alarm The dc3400 SC is in alarm and all programmed relays sounders and outputs will be activated LED display Alarm double LED is on The Alarm relay from the basic module is activated standard programming Main alarm LED is on External sounders are activated if they have not been disabled or in fault Call Fire Brigade LED is on Please inform the Fire and Rescue Service immediately Display On the display information regarding the device activated and the programmed message texts are displayed In the centre of the display in which you can scroll using the 4 and x keys the first message is displayed In the bottom field you are always shown the last current or pending message The alarm display is zone related The alarm counter only counts the zones that are in alarm If more detectors from one zone are in alarm the number of detectors is displayed on the right between the a and v keys e g two more detectors In order to view these additional detectors from that zone touch this key 5 2 2 Alarm delay amp detector zone dependency The FCP dc3400 SC is in alarm state of a detector dependency zone de
32. scroll using the 4 and keys the first a Ie ae a i message is displayed In the bottom field you are always shown the last message alarms pang buzzer on off 5 4 2 Maintenance mode When the dc3400 SC is in maintenance mode the system can be tested without activating Maintenance mode Dlease select alarms or outputs ease select Enable zones for maintenance Disable zones from maintenance a Enable detectors for maintenance LED display Disable detectors from maintenance Enable system outputs for maintenance e The yellow LED Maintenance Mode is on Disable system outputs from maintena Display e A message will be displayed specifying which zones detectors or outputs have been Transm Unit switched into maintenance mode e f a maintenance alarm is triggered this will be displayed according to the Alarm Display The triggered detector will be reset after approx 40 seconds Version 2 1 14 Operation Manual FCP dc3400 SC 6 Operation procedures at events 03 12 2010 10 51 48 Mrs kl EA II Kl Mrs kl EA II Alarms 0001 Alarm Z 0001 D 24 EJ KT Unit EA Delay Reset KEE art ES bod kel EA me Kull En 09 aa 03 12 2010 12 08 59 0001 Detector 1st knock Z 0002 D 9 PL 3300 0 Alarms 0001 Alarm Z 0002 D 9 a Silence Transm Unit Mute Delay Reset Aam Attention Regard to your alarm organisation in case of fire alarm events 6 1 Alarm Main alarm When the dc340
33. tenance alarm is triggered this will be displayed in the Mainten notes The zones or detectors in maintenance mode will also be indicated in the Mainten notes window 5 3 Faults LED display e Fault double LED is flashing in yellow Display e Amessage appears specifying the fault e Inthe centre of the display where you can scroll using the 4 and keys the first message is displayed In the bottom field you are always shown the last message After the fault has been rectified there are two possibilities for resetting the dc3400 SC e Fault is reset automatically e g in the case of an open circuit or a missing detector e Fault is reset by pressing the Reset key Warning Defective detectors zones inputs and outputs will not trigger an alarm Inform the Service or maintenance company Version 2 1 13 ZOON JOO Nee detectamat Operation Manual FCP dc3400 SC 5 4 Maintenance Service Warning Any detectors zones or mappings which are in maintenance mode will not activate any fire alarm outputs in case of events 5 4 1 Disablements AFA ki E gt ments LLLI 0000 Sin DOOI 0000 e Disabled yellow LED is on 06 12 2010 11 21 57 06 12 2010 11 19 38 0001 Disabled Display Sounders e A message will be displayed specifying the disablement In this example the Sounder are via display disabled e Inthe centre of the display in which you can
34. the and 4 keys 2 Press the Ok button 3 Proceed in the same way in order to access the remaining sub menus oe 7 1 Operating authorisation access Levels Base module Authorisation for operating the FCP dc3400 SC is by means of different passwords When seta i EA Sere A prompted to do so enter the password directly from the display Each entered number is shown by the symbol After the entry of the password the Ok button must then be pressed In the case of a wrong entry the number s can either be deleted using the key or the entry can be cancelled using the lt key Operation of the FCP dc3400 SC is governed via two different password levels which are user authorisation specific Password level 2 should only be accessible for authorised operators A The use of the password and there levels are described in the Installation Manual FCP dc3400 SC Base module ID System parameters password level 3 WEE Service configuration password level 2 Basic functions password level 1 Password levels Operation according to functions 1 2 3 Silence Ext sounders sf x TU enable disable Pf x Mute buzzer Px fo nn Delay enable disable ex ab ENE Disable xf mmm Se En 2s and detec System parameters Lae Setting date and time Px fo Lamp test xf Language setting Px fo Alarm counter Px fo Version 2 1 17 ZOON JOO Nee detectomat Operation Manu
35. trig Alarm caused via a zone dependency Fire Z1 knock trig Alarm with an enabled delay Maintenance mode alarm e Detector dependency Fire D1 knock trig The main alarm will become active as soon as two detectors or MCP from the same zone become active e Zone dependency Fire Z1 knock trig The main alarm is activated as soon as two defined zones go into alarm Version 2 1 15 ZOON JOO Nani detectomat fl detect control dc3400 Operation Disabled CC O Dis Extinguish Syst Main Alarm we oy Fire Brigade Called _ le atter Call Fire Brigade System Key Box Sabotage 0 O Ext Outputs Key Box Open oO Maintenance Mode Delay ON oO Earth Fault B Transm Unit Alarm Operation Manual FCP dc3400 SC e Alarm with the delay active The main alarm will become active once the delay time or Intervention Time has expired e Maintenance mode alarm A maintenance mode alarm will not raise a main alarm and is only for service purposes Detectors in maintenance alarm will be indicated for 40 sec in the Mainten notes window Recommendations for the operating sequence 1 Press the Mute buzzer key The internal buzzer is disabled 2 Proceed according to the present Instructions in the case of an alarm 3 Once the cause of the alarm has been found and rectified press the Reset button and all modules and detectors are reset If the ext sounders have been disabled they will
36. tteries should only be disposed in official waste management plants Your local environmental authority can provide you with addresses of waste management plants Version 2 1 27
37. uts and outputs e External alarm signals e Transmission units alarm amp fault e Fire case controls e Output fire protection e Extinguish command Not available at present 1 Starting from the In operation screen press the following key combination Menu Disable Press the Ok button The password prompt appears Enter the password Press the Ok button in order to confirm the entry The Disablements menu opens Select one of the following options e Detector e Zone e Output e External alarm signals GI R N all further listed menu items have no function at present An enabling or disabling of these items has no effect to the FCP dc3400 SC or the system Version 2 1 19 detectamat Disable Detector Sub Panel 4 zone from Detector 5 to Detector E Disable Zone Transm Unit Mute Delay bent Disable Output Please select Base module Sub Panel Address from Output 4 to Output Transm Unit Mute Delay BOT Operation Manual FCP dc3400 SC 1 4 1 Disabling detectors In the disable detector menu you can select which detectors you want to disable 1 Starting from the In operation screen press Menu Disable Detector you will see the following 2 Touch the Sub Panel entry field and enter the number of the desired panel via the keypad 3 Touch the Zone entry field and enter the zone number 4 Touch the
38. yS enasuurnnnnsenrennnnnnerennnnnsnn 24 AUE MESSAGES ane aki tod ce i aaa aia E aia 24 MEIE AA 26 kasel AAI 26 9 1 1 inspection Periods ecciesia eneen dine t t 26 9 1 2 Batteri S rans avorensrsrrnnorereneverenaversnnsvenensvenensvenenaoverensvenenaverenaone 26 919 Charging VY OAC E sessa 27 Cleaning POE 27 DOV ale UDG ALCS waaren sersternrabendeeierdemdhendseieerdsandbandeedntenimenninbendadenteendtdeetaanntene 27 Environmentally friendly disposal neen nennen eeneeerennerrenseerreneeerenvens 27 Version 2 1 4 Operation Manual FCP dc3400 SC 1 Operation manual purpose and structure 1 1 Purpose of this manual This user manual has been written for technically qualified users who have been or will be appointed or especially trained for the use of the dc3400 SC central fire alarm system hereinafter only referred to as FCP dc3400 SC The prerequisite for the use of the manual is a completely commissioned FCP dc3400 SC which has been configured in correspondence with the requirements of the user Being the operator and the user of the central fire alarm system you are obliged to read and understand this manual especially section 2 General Safety Instructions on page 6 This user manual contains the relevant information with regards to the operation and the maintenance procedures of this system Its intention is to provide you with important information with regard to the intended efficient and safe use of the FCP dc3400